Loading...
2312848 KINGSLEY 77 19TH ST, ATLANTIC FL 32233 (EFILE) DWG_1REVISION 2: REVISION 1: DESIGN DATE: SCALE: NTSCONTRACTOR:PROJECT ADDRESS:DATE DATE RJ/IAThis item has been electronically signed and sealed by Craig E. Gunderson, P.E. on date below using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.DRAWN BY:CA CERT. #30782FLORIDA ENGINEERING LLC4161 TAMIAMI TRAIL, UNIT 101PORT CHARLOTTE, FLORIDA 33952(941) 391-5980FLEng.comOrders@FLEng.comTHESE PLANS WERE PREPARED AND SHALL COMPLY WITH THE a. FLORIDA STATE: -2020 FLORIDA BUILDING CODE 7th EDITION, RESIDENTIAL, CHAPTER NO. 45, SECTION: E4501 -2020 FLORIDA BUILDING CODE 7th EDITION, ENERGY CONSERVATION, CHAPTER NO. 4 -2020 FLORIDA STATUTES, CHAPTER NO. 515 RESIDENTIAL SWIMMING POOL SAFETY ACT b. FEDERAL GOVERNMENT: -2014 ANSI/ APSP/ ICC-3: AMERICAN NATIONAL STANDARD FOR PERMANENTLY INSTALLED RESIDENTIAL SPAS SWIM SPAS R4501.6.1 -2011 ANSI/ APSP/ ICC-5: AMERICAN NATIONAL STANDARD FOR RESIDENTIAL INGROUND SWIMMING POOLS R4501.6.1 -2013 ANSI/ APSP-7: AMERICAN NATIONAL STANDARD FOR SUCTION ENTRAPMENT AVOIDANCE IN SWIMMING POOLS, WADING POOLS, -2013 ANSI/ASHRAE-15: SAFETY STANDARDS FOR REFRIGERATION SYSTEMS. SPAS, HOT TUBS AND CATCH BASINS R4501.6.1, R4501.6.3, R4501.6.6 -2012 ANSI/ APSP/ ICC 4-12 AMERICA NATIONAL STANDARD FOR ABOVE-GROUND/ ON-GROUND RESIDENTIAL SWIMMING POOLS R4501.6.1. -2013-ANSI/ APSP/ ICC 6-13 AMERICA NATIONAL STANDARD FOR RESIDENTIAL PORTABLE SPAS AND SWIM SPAS -2017 NATIONAL ELECTRICAL CODE (NEC)ARTICLE NO. 680 SECTION: R403.12 RESIDENTIAL POOL AND PERMANENT SPA SECTION: R403.11 PORTABLE SPA (MANDATORY) SECTION: R403.10 POOLS AND PERMANENT SPA ENERGY CONSUMPTION (MANDATORY) AS WELL AS ANY ADDITIONAL REQUIREMENTS PER LOCAL MUNICIPALITY THAT MAY BE MORE STRINGENT ACCORDANCE WITH THE FLORIDA BUILDING CODE, AND ALL CONSTRUCTION SHALL MEET ALL APPLICABLE CODES INCLUDING PLUMBING, ELECTRICAL AND GAS. ACCEPTABLE ARE STAIRS (10” MINIMUM TREAD WITH 240 SQUARE INCH MINIMUM AREA, 12” RISER WITH INTERMEDIATE TREADS AND RISERS UNIFORM). LADDERS, UNDERWATER SEATS, AND SWIM-OUTS (MAXIMUM 20” BELLOW WATERLINE 1. TILE MINIMUM CONCRETE COVER FOR #3 REBAR IS TO BE 2". OR (1) 8 AWS BARE SOLID COPPER BONDING CONDUCTOR (2) THE BONDING CONDUCTOR MUST FOLLOW THE CONTOUR OF THE PERIMETER SURFACE (4) BONDING CONDUCTOR MUST BE 18 TO 24 INC. FROM THE INSIDE WALLS OF THE POOL LIGHTS, LIGHT TRANSFORMERS, HANDRAIL AND LADDER DECK ANCHORS, WINDOW AND DORRR FRAMES WITHIN 5 FEET OR LESS OF THE - ALL CONTROL ENCLOSURES (INCLUDING ACCESSORY ELECTRONIC EQUIPMENT WITH METAL ENCLOSURES), PUMP MOTORS, HEATERS, (3) LISTED SPLICING DEVICES -NEC 2017, 680, 26 (B) (2) (b) ALTERNATE MEANS EQUIPOTENT BONDING CONDUCTOR MUST FOLLOWING REQUIREMENTS: (5) BONDING CONDUCTOR MUST BE WITHIN OR UNDER THE PERIMETER SURFACE 4 TO 6 IN. FAMILY DWELLING IS REMOVED FROM THE 2020 FBC). LIMITED TO 6 FEET PER SECOND (FPS) WHEN ONE OF A PAIR IS BLOCKED. IN NORMAL OPERATION THEN, THE BRANCH SUCTION PIPING VELOCITY IS 3 FEET PER SECOND. ALL OTHER SUCTION PIPING VELOCITIES - THE MAXIMUM SYSTEM FLOW RATE SHALL BE DETERMINED BY ONE OF THE FOLLOWING: SYSTEM NOW RATE USING THE SHORTEST DISTANCE BETWEEN THE POOL AND THE PUMP. OMITTING THE CALCULATIONS FOR FIT LINGS/ VALVES, AND USING THE BEST PERFORMANCE RATINGS FOR FILTERS AND HEATERS: OR TDH CALCULATION FOR THE CIRCULATION SYSTEM OF EACH PUMP, OR A SIMPLIFIED TDH CALCULATION. DETERMINES THE MAXIMUM THE MAXIMUM FLOW CAPACITY OF THE PUMP, WHICH SHALL BE LIMITED BY THE CRITERIA OF ANSI/ APSP-7-4.4 (NOTE ABOVE). - ALL POOL PUMP MOTOR'(S) TO HAVE GFCI PROTECTION (NEC 680.22 (B), FBC SECTION 27), AND FRC 4101.16 (EXCEPTION FOR SINGLE -FILTER BACKWASH VALVE (WHEN USED) MUST BE 2" (MIN.) CONSTRUCTION CODE REQUIREMENTS IMPORTANT NOTE: GENERAL STRUCTURAL NOTES: ELECTRICAL REQUIREMENTS: VELOCITY AND FLOW RATE NOTES: FILTERS SPECIAL SPA REQUIREMENTS: GENERAL POOL / SPA REQUIREMENTS: C. D.E. = 2 A. CARTRIDGE = 0.375 B. SAND = 15 OR DIAMETER OF THE RETURN PIPE, WHICHEVER IS GREATER. FILTER SIZE TO BE DETERMINED BASED ON CALCULATED FLOW RATE (GPM) DIVIDED BY THE FOLLWING FILTER CAPACITY (PER APSP -15): POOL CONTRACTOR IS RESPONSIBLE FOR CONFORMING TO ALL ABOVE LISTED CODE REQUIREMENTS THAN THE ABOVE LISTED CODES REQUIREMENTS. - THE POOL CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL DETAIL DESIGN REQUIREMENTS FOR EACH INDIVIDUAL POOL IN - SEE ANSI/ NSPI-5 FOR DIVING WATER ENVELOPS. - SLIDERS SHALL ALSO MEET THE MANUFACTURER'S INSTALLATION REQUIREMENTS. - LADDER OR STAIRS ARE TO BE PROVIDED. ENTRY/ EXIT REQUIRED AT THE SHALLOW END AND DEEP END IF OVER 5 FEET DEEP - OUTDOOR SWIMMING POOLS ARE TO HAVE BARRIERS THAT COMPLY WITH THE FLORIDA BUILDING CODE. - ALL WALL SURROUNDING INDOOR SWIMMING POOLS SHALL COMPLY WITH THE FLORIDA BUILDING CODE. - FINAL ELECTRICAL, AND BARRIER CODE, INSPECTIONS SHALL BE COMPLETED PRIOR TO FILING THE POOL WITH WATER. - MIN. TREAD 10” X 12” MAX. RISER. -FLOOR SLOPE 1:12 -MAXIMUM WATER DEPTH 4', MAXIMUM SEAT DEPTH 28”. 2. CONTINUOUS #3 REBAR SPLICES SHALL BE 18" (40 BAR DIAMETERS) MINIMUM LAP, STEEL TO BE BENT, LAPPED, AND PLACED IN CONFORMANCE WITH A.C.J. STANDARDS AND SPECS. 3. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF NOT LESS THAN 3000 PSI AT 28 DAYS. -WIRING AND BONDING AND ALL ELECTRICAL SHALL CONFORM TO NEC ARTICLE 680 (2017). -NO OUTLET OR OVERHEAD POWER WITHIN 10', IF WITHIN 15' PROJECT WITH GFI. -BRASS FITINGS TO J-BOX OR TRANSFORMER WHICHEVER IS FIRST WHICHEVER IS FIRST, EXCEPT WHERE PVC IS APPROVED. -BONDING GRID PER NEC 2017 680, 26 BELOW THE SUBGRADE. WATER'S EDGE ARE TO BE GROUNDED IN ACCORDANCE WITH ARTICLE 680 OF THE 2017 NEC. MAXIMUM WATER VELOCITY IN BRANCH SUCTION PIPING (SHOWN IN FIGURE 1) SHALL BE - WATER VELOCITY IN FIELD-FABRICATED PIPING IS BASED ON THE MAXIMUM SYSTEM FLOW RATE. SHALL BE 8 FPS FOR RESIDENTIAL POOLS. MANUFACTURER'S RECOMMENDATIONS. MAINTENANCE AND SERVICING. -CIRCULATION SYSTEMS, COMPONENTS AND EQUIPMENT SHALL COMPLY WITH NSF 50. MINIMUM EACH. A112.12.8M AND ANSI/APSP-7. -THE MAXIMUM SYSTEM FLOW RATE "SEE TDH CALCULATIONS FOR NOTES". -ACCESSIBILITY AND CLEARANCE, EQUIPMENT SHALL BE SO INSTALLED AS TO PROVIDE READY ACCESSIBILITY FOR CLEANING, OPERATING, APART, EXCEPT THERAPY JETS AND SWIM JETS. -PIPING SHALL BE SCHEDULE 40 PVC, NSF-PW, MAXIMUM PRESSURE VELOCITY 10 FT/S, AND SUCTION 8 FT/S. USE. OPENINGS IN THE LID, OR THROUGH A SEPARATE VENT PIPE, DESIGNED IN ACCORDANCE WITH ANSI-APSP-7 7.2, OR INCORPORATE AN SUCTION OUTLET COVER/ GRATE WITH A HOW RATING EQUAL TO THE MAXIMUM SYSTEM SLOW DIVIDED BE THE NUMBER OF SKIMMERS FITTING SHALL COMPLY WITH IAPMO SPS. CLEANERS). IN ADDITION, THE VACUUM PIPING SHALL BE EQUIPPED WITH A VALVE TO REMAIN IN THE CLOSED POSITION WHEN NOT IS HYDRAULICALLY DESIGNED TO THE MAXIMUM FLOW RATE OF THE POOL. SKIMMERS SHALL BE VENTED TO ATMOSPHERE THROUGH WHEN PIPED THROUGH A COMMON SUCTION LINE, OR THE MAXIMUM FLOW RATING OF THE SKIMMER, WHICHEVER IS GREATER (SEE 6 INCHES (152 MM) AND NO GREATER THAN 18 INCHES (457 MM) BELOW THE WATER LEVEL AND THE SELF-CLOSING, SELF-LATCHING GRATE SHALL BE AT LEAST EQUAL TO THE SYSTEMS MAXIMUM FLOW RATE. FEEDING FROM THE COMMON LINE BETWEEN THE SUCTION OUTLETS, TO THE PUMPS(S) SHALL BE LOCATED APPROXIMATELY MIDWAY. - THREE OR MORE LISTED SUCTION OUTLETS ARE PIPED IN PARALLEL TWO OF THE OUTLETS SHALL BE PIPED WITH THE TEE FEEDING THE SUCTION LINE TO THE PUMP(S) LOCATED APPROXIMATELY MIDWAY BETWEEN THE TWO OUTLETS. THE ADDITIONAL OUTLET (S) - A SINGLE LISTED CHANNEL OUTLET SHALL BE CONSIDERED ACCEPTABLE IF THE SIZE OF THE PERFORATED AREA IS 3" OR GREATER IN WIDTH AND 31" OR GREATER IN LENGTH. - SINGLE OUTLET SWIM-JET SYSTEMS CONSIST OF A COMBINATION FITTING THAT INCORPORATES A SUCTION OUTLET AND INLET IN A SINGLE HOUSING THAT IS DESIGNED TO MOVE A LARGE VOLUME OF WATER AT HIGH VELOCITY IN A SINGLE DIRECTION. SUCH SYSTEMS SHALL BE TESTED AND LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY AS CONFORMING TO THE MOST RECENT EDITION OF ASME/ ANSI 112.19.8 AND INCLUDE A PERMANENTLY MARKED FLOW RATING TESTED TO PREVENT HAIR ENTRAPMENT. THEY ARE NOT GOVERNED BY THE VELOCITY LIMITATIONS OF ANSIFAPSP-7-4.4. SUCTION TYPE - SKIMMER / VACUUM NOTES: SUCTION TYPE - MAIN DRAIN / SUCTION OUTLET NOTES: EQUIPMENT/PIPING REQUIREMENTS: - EQUIPMENT FOUNDATIONS AND ENCLOSURES ALL POOL MOTORS AND EQUIPMENT SHALL BE INSTALLED IN COMPLIANCE WITH THE - THE MAXIMUM TURNOVER RATE IS 12 HOURS. - ALL FILTERS SHALL HAVE AN AIR RELEASE AND PRESSURE GAUGE. - SURFACE SKIMMERS SHALL MEET NSF 50 AND THERE SHALL BE ONE FOR EVERY 800 SQUARE FEEL OR SURFACE AREA ANDA 25 GPM - RETURN INLETS SHALL BE A MINIMUM OF ONE FOR EVERY 300 SQUARE FEET, RETURN VELOCITY 10FT/S, SPACING OF 10 FEET MINIMUM - HYDROSTATIC RELIEF DEVICE, IN AREAS OF ANTICIPATED WATER TABLE AN APPROVED HYDROSTATIC REFIEF DEVICE SHALL BE INSTALLED. VALVES SHALL BE APROVED BY THE FLORIDA BUILDING CODE. - HEATER SHALL MEET ANSE-Z21.56 OR UL 1261 OU UL 559 AND ANSI/APSP. - DISINFECTANT EQUIPMENT SHALL COMPLY WITH NSF-50 ANSI/NSPI-4-12 AND ANSI/NSPI-5 2011 BYPASS ON HEATERS. - PRIMER AND GLUE ON EXPOSED ABOVE-GROUND ARE PIPING NOT REQUIRED TO BE COLORED. - MAIN DRAINS ARE OPTIONS "SEE TDH CALCULATIONS" OF THIS SET FOR DETAILS AND SPECIFICATIONS. - VACCUM CLEANER SUCTION FITTINGS SHALL BE PROTECTED BY A PERMANENTLY SELF-CLOSING FLAPPER VALVE MEETING ANSI/ASME - ALL RETURN INLETS MUST BE DIRECTIONAL INLET FITTINGS. - THE FOLLOWING SHALL BE LABELED AT THE CIRCULATION EQUIPMENT LOCATION: PIPE VALVES PUMP(S) OFF SWITCH - ENTRAPMENT PROTECTION FOR SUCTION OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ANSI/PPS-7-13 -HAIR AND LINT STRAINERS ARE TO BE USED WITH RECIRCULATION SYSTEMS. -FILTER COMPONENTS SHALL HAVE SUFFICIENT CAPACITY TP PROVIDE A COMPLETE TURNOVER OF POOL WATER IM TWELVE (12) HOUR OR LESS. FROM THIS REQUIREMENT. -FILTRATION PUMPS TO BE SIZED (BASED ON CALCULATED FLOW RATE IN GPM) TO TURNOVER POOL VOLUME IN SIX (6) HOUR MINIMUM OR 36 GPM (MIN.) WHICHEVER IS GREATER. DEFAULT CIRCULATION MUST BE THE RESIDENTIAL FILTRATION (SLOWER) SPEED. THE SIMPLIFIED TOTAL DYNAMIC HEAD SHEET TO BE CALCULATED AND PLUMBING SIZE DETERMINED BASED ON (HIGHER) SPEED. THE HIGHER SPEED OVERRIDE IS NOT TO EXCEED ONE NORMAL DAY'S CYCLE OR 24 HOURS, WHICHEVER IS LESS I.E.: CONTROLLER RESETS PUMP TO SLOWER SPEED AT THE START OF THE NEXT CIRCULATIONS CYCLE. LINE SHOULD HAVE (4 X 2" DIA.) 8" OF STRAIGHT PIPE FOM SUCTION INLET TO THE FIRST PVC FITTING. PUMPS: ENTRAPMENT PROTECTION FOR SUCTION INLETS: - WHERE REQUIRED MEET FBC 2020 GAS AND MECHANICAL CODES (OR CODES CURRENTLY ENFORCER WITH MUNICIPALITY) - RECIRCULATION PUMPS LESS THAN ONE HORSEPOWER (1 HP) SHALL BE TWO OR MORE PUMPS WITH ADEQUATE CONTROLLER. THE - PUMPS THAT ARE USED FOR CIRCULATION ONLY (WITHOUT FILTRATION). SPA THERAPY PUMPS OR WATER FEATURE PUMPS ARE "EXEMPT" - POOL FILTRATION PUMPS SUCTION LINE (BEFORE PUMP) SHALL HAVE A STRAIGHT LENGHT OF PIPE (4 PIPE DIAMETERS MIN.) I.E.: 2" SUCTION - MAIN DRAINS ARE NOT REQUIRED. WHEN MAIN DRAINS ARE NOT INCLUDED THE SKIMMER OR SURFACE OVERFLOW MUST BE - WITH THE CENTER NO MORE THAN 18 INCHES (457 MM) BELOW THE MAXIMUM OPERATING LEVEL. IT SHALL BE PROTECTED BY A LISTED - WALL VACUUM FITTING (S). WHEN USED, VACUUM CLEANER FITTING(S) SHALL BE LOCATED IN AN ACCESSIBLE POSITION(S) AT LEAST - SPECIAL USE SUCTION FITTING FOR SWIMMING POOLS, SPAS AND HOT TUBS (FOR SUCTION SIDE AUTOMATIC SWIMMING POOL - DUAL OUTLETS, I.E., TWO LISTED SUCTION OUTLETS, ARE PIPED TO A SINGLE, COMMON SUCTION LINE TO THE PUMPS(S). THE TEE - DUAL OUTLETS SHALL BE SEPARATED BY A MINIMUM OF 3 FEET (914 MM) MEASURED FROM CENTER TO CENTER OF THE SUCTION PIPES EQUALIZER LINE. (SEE FIGURE ON SHEET 04). SKIMMER EQUALIZER LINES, WHEN USED SHALL BE LOCATED ON THE WALL. FIGURE ON SHEET 04). - BETWEEN THE OUTLETS WITH NOW OUT OF THE BRANCH OF THE TEE. SEE FIGURES ON SHEET 04. THE FLOW RATING OF EACH COVER/ WALL, OR ONE (1) EACH ON TWO (2) SEPARATE VERTICAL WALLS. (SEE SHEET 04). SHALL BE PERMITTED WHEN PIPED ACCORDING TO FIGURES ON SHEET 04. (SEE FIGURES ON SHEET 04) OR LOCATED ON TWO (2) DIFFERENT PLANES, I.E. ONE (1) ON THE BOTTOM AND ONE (1) ON THE VERTICAL PREMIER POOLS AND SPAS1905 PROMENADE WAYJACKSONVILLE FL 32207KINGSLEY 77 19TH ST, ATLANTIC FL 3223305/19/2023 PROJECT NO. 2312848 DRAWING INDEX DETAILS S/01 S/02 S/03 S/04 PLAN/ ELEVATIONS GENERAL NOTES SHEET NO. DETAILS SHEET :01 -MAXIMUM TEMPERATURE 104 DEGREES. -INTERMITTENTLY THE SPA SHALL HAVE A ONE HOUR TURNOVER, IF CONTINUOUS A SIX HOUR TURN OVER. REVISION 2: REVISION 1: DESIGN DATE: SCALE: NTSCONTRACTOR:PROJECT ADDRESS:DATE DATEThis item has been electronically signed and sealed by Craig E. Gunderson, P.E. on date below using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.DRAWN BY:CA CERT. #30782FLORIDA ENGINEERING LLC4161 TAMIAMI TRAIL, UNIT 101PORT CHARLOTTE, FLORIDA 33952(941) 391-5980FLEng.comOrders@FLEng.comWHERE A WALL OF DWELLING SERVES AS PART OF THE BARRIER, ONE OF THE FOLLOWING SHALL APPLY: 1) ALL DOORS AND WINDOWS PROVIDING DIRECT ACESS FROM THE HOME/ DWELLING TO THE POOL SHALL BE EQUIPPED W/ AN EXIT ALARM COMPLYING W/ UL 2017. 2) ALL DOORS PROVIDING DIRECT ACCESS FROM THE HOME TO THE POOL MUST BE EQUIPPED W/ A SELF-CLOSING, SELF-LATCHING DEVICE W/ POSITIVE MECHANICAL LATHCING/ LOCKING INSTALLED A MIN. OF 54 INCHES ABOVE THE THRESHOLD, WHICH IS APPROVED BY THE AUTHORITY HAVING JURIDICTION. 3) A SWIMMING POOL ALARM THAT COMPLIES TO ASTM STANDARD F2208. OUTDOOR RESIDENTIAL SWIMMING POOLS SHALL BE PROVIDED WITH A BARRIER COMPLYING WITH 2020 FBC R4501.17.1.1 THROUGH R4501.17.1.14. FOR ALL WALKING SURFACES LOCATED MORE THAN 30" ABOVE GRADE, GUARDS SHALL BE PROVIDED PER 2020 R312. APPROVED SURFACE SKIMMERS ARE REQUIRED AND SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. SKIMMERS SHALL BE INSTALLED ON THE BASIS OF ONE PER 800 SQUARE FEET (74 M2) OF SURFACE AREA OR FRACTION THEREOF, AND SHALL BE DESIGNED FOR A FLOW RATE OF AT LEAST 25 GALLONS PER MINUTE (GPM) (1.6 L/S) PER SKIMMER. ENTRAPMENT PROTECTION FOR SUCTION OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ANSI/APSP/ICC-7 & 2020 FBC R4501.6.6. THE NUMBERS OF RETURN INLETS SHALL BE BASED ON A MINIMUM OF (1) RETURN INLET PER 300 SQ. FT. OF POOL SURFACE AREA OR FRACTION THEREOF. EQUIPOTENTIAL BONDING SHALL CONFORM TO 2017 NEC SECTION 680.26. ENTRY/ EXIT REQUIRED AT THE SHALLOW END AND DEEP END IF OVER 5 FEET DEEP. ACCEPTABLE ARE STAIRS (10” MINIMUM TREAD WITH 240 SQUARE INCH MINIMUM AREA, 12” RISER (MAX.) WITH INTERMEDIATE TREADS AND RISERS UNIFORM). LADDERS, UNDERWATER SEATS, AND SWIM-OUTS (MAXIMUM 20” BELLOW WATERLINE). ANY GLAZING WITHIN 5 FT. OF POOL SHALL BE SHALL CONFORM TO FBC R308.4.5. HYDROSTATIC RELIEF DEVICE, IN AREAS OF ANTICIPATED WATER TABLE AN APPROVED HYDROSTATIC REFIEF DEVICE SHALL BE INSTALLED. VALVES SHALL BE APROVED BY THE FLORIDA BUILDING CODE. LOWEST POINT OF POOL, CLOSEST TO STRUCTURE A: THE POOL'S CLOSEST POINT TO THE STRUCTURE LOWEST POINT OF STRUCTURE CLOSEST TO POOL B°A ANGLE OF REPOSE B: ANGLE OF REPOSE (NOT TO EXCEED 45 DEGREES) FBC 1804.1 EXCAVATION NEAR FOUNDATIONS: EXCAVATION FOR ANY PURPOSE SHALL NOT REDUCE VERTICAL OR LATERAL SUPPORT FOR ANY FOUNDATION OR ADJACENT FOUNDATION WITHOUT FIRST UNDERPINNING OR PROTECTING THE FOUNDATION AGAINST DETERMENTAL LATERAL OR VERTICAL MOVEMENT, OR BOTH. 05/19/2023 SHEET :0220" MAX.WATERLINE 18" TYP.REFER POOL WALL DETAILS SWIMOUT BENCH TYPICAL DETAIL NOTE: 1) WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE WATERLINE AS SHOWN, AND SHALL BE VISUALLY SET APART FROM THE POOL. 2) MIN. UNOBSTRUCTED WAKLING SURFACE OF 240 SQ. INCHES. POOL PLAN SCOPE OF WORK: RESIDENTIAL SWIMMING POOL ENGINEERING (POOL NOT DESIGNED FOR DIVING) POOL IN FLOOD HARZARD AREAS (WHEN APPLICABLE, CONTRACTOR TO VERIFY): A) 2020 FBC R322.1.6 PROTECTION OF MECHANICAL, PLUMBING AND ELECTRICAL SYSTEMS: ELECTRICAL SYSTEMS, EQUIPMENT AND COMPONENTS; HEATING, VENTILATING, AIR CONDITIONING; PLUMBING APPLIANCES AND PLUMBING FIXTURES; DUCT SYSTEMS; AND OTHER SERVICE EQUIPMENTS SHALL BE LOCATED AT OR ABOVE THE ELEVATION REQUIRED IN SECTION R322.2 OR R322.3. EXCEPTION (2020 FBC 1612.4.2): EQUIPMENT FOR POOLS, SPAS AND WATER FEATURES SHALL BE PERMITTED BELOW THE ELEVATION REQUIRED IN TABLE 7-1, PROVIDED IT IS ELEVATED TO THE EXTENT PRACTICAL, IS ANCHORED TO PREVENT FLOATION AND RESIST FLOOD FORCES, AND IS SUPPLIED BY BRANCH CIRCUITS THAT HAVE GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION. B) 2020 FBC R322.2.1 ELEVATION REQUIREMENTS. BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS, INCLUDING FLOOD HARDARD AREAS DESIGNATED AS COASTAL A ZONES, SHALL HAVE THE LOWEST FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION PLUS 1 FOOT (305 MM), OR THE DESIGN FLOOD ELEVATION, WHICHEVER IS HIGHER.KINGSLEY 77 19TH ST, ATLANTIC FL 32233PROJECT NO. 2312848 PREMIER POOLS AND SPAS1905 PROMENADE WAYJACKSONVILLE FL 32207RJ/IA 4' T T T R UMB T T T 4' Firepit (By Others) R R HVAC Existing Residence Pool Equipment 32" Channel Drain16'-6" 8'-0"5'2'7'-6"30'7'12'10'3'3' Swimout Spill way R 3'-6" Deep5'-6" Deep Pool Light StepsReturn Spa Sun shelf w/(1) Bubbler Pool deck Umbrella 36' Cabana (By Others) POOL EQUIPMENT SCHEMATIC EXAMPLE TP104 120V/10120V/10120V/10120V/10120V/10120V/10 NOTE: POOL AND SPA EQUIPMENT TO BE MOUNTED ON A SUBSTANTIAL BASE IN A MANNER THAT ELIMINATES PIPE STRAIN, AND MAY NEED RATED STRAPPING IN ACCORDANCE WITH LOCAL HURRICANE CODES. (3) #10 THHN CU IN 3/4" PVC CONDUIT (3) #10 THHN CU IN 3/4" PVC CONDUIT LIGHT CORD IN 1" PVC CONDUIT 100 OR 300 WATT POOL LIGHT JUNCTION BOX 100 WATT TRANSFORMER ELECTRICAL SUB PANEL OR DISCONNECT TIME CLOCK SPA MAIN DRAIN BLOWER POOL MAIN DRAIN (OPTIONAL) POOL SKIMMER POOL VACUUM AIR LINE TO SPA JETS 4 x PIPE DIAMETER FILTRATION PUMP HEAT PUMP/ HEATER FILTER SPA THERAPY JETS SPA RETURN POOL RETURN CHLORINATOR POOL SUCTION REVISION 2: REVISION 1: DESIGN DATE: SCALE: NTSCONTRACTOR:PROJECT ADDRESS:PREMIER POOLS AND SPAS1905 PROMENADE WAYJACKSONVILLE FL 32207KINGSLEY 77 19TH ST, ATLANTIC FL 3223305/19/2023 DATE DATE RJ/IAThis item has been electronically signed and sealed by Craig E. Gunderson, P.E. on date below using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.PROJECT NO. 2312848 DRAWN BY:CA CERT. #30782FLORIDA ENGINEERING LLC4161 TAMIAMI TRAIL, UNIT 101PORT CHARLOTTE, FLORIDA 33952(941) 391-5980FLEng.comOrders@FLEng.comSTEEPEST ALLOWABLE SLOPE BEFORE BREAK 1 3 7 1 6" (R MAX.) WATERLINE 2'-9" MIN.1 1 D E G . M A X .STEEPEST ALLOWABLE SLOPE BEFORE BREAK 6' MIN. POINT "D" ALLOWABLE POOL FLOOR & WALL GEOMETRY28"WATERLINE COMPACTED FILL WIRE AND CLAMP #8 GROUND HANDRAIL - OPTIONAL (WHERE APPLICABLE PER ANSI-5) IN CONCRETE RAILING ANCHOR SET SET HANDRAIL IN BOTTOM TREAD USING QUICK DRY CEMENT GROUT STEP NOTE: RISER = 12" MAX. (TYP.) TREAD = 10" -12" TYP. - THE LAST RISER MAY EXCEED 12 IN. IF WATER DEPTH IS OVER 48 IN. AT THAT POINT. - TREADS MINIMUM UNOBSTRUCTED WALKING SURFACE = 240 SQ. INCHES. NOTE: ALL JOINTS SHALL BE CONTRACTELESS THAN 1/16" WIDE. NOTE: THIS TYPE OF DECK FINISH (LAST ROW OF PAVERS) TO BE USE ONLY IF NO ADDITIONAL LOADS WILL BE APPLIED ON DECK (REEN, FENCE, ETC.) COMPACTFILL, 12" MIN. OR THE PAVERS ED SOD TROWEL CONCRETE (FRESH CONCRETE) 2% MIN./4% MAX DECK SLOPE PAVERS, POOL DECK PERIMETER PAVERS 1-1/2" COMPACTED SAND BED IN ACCORDANCE W/ MANUFACTURER'S INSTALATION SPECIFICATIONS 3/8" EXPOSED AGGREGATE OR MARSITE FINISH 3000 PSI CONCRETE AT 28 DAYS6"6" SEE POOL/ SPA REINFORCEMENT DETAILS INTERLOCKING PAVERS, FOOTING AND TYP. DECK DETAIL ANSI/ APSP- 5 SECTION 17.2 ROPE AND FLOAT: - IN POOLS WHERE THE POINT OF FIRST SLOPE CHANGE (POINT D, FIGURE BELOW) OCCURS IN WATER DEPTHS LESS THAN 4'-6", A ROPE AND FLOAT ASSEMBLY SHALL BE INSTALLED ACROSS THE WIDTH OF THE POOL GENERALLY PARALLEL TO, AND AT A MIN. OF 1 FT. AND A MAX. OF 2 FT. ON THE SHALLOW SIDE OF THE CHANGE IN FLOOR SLOPE. POOL FLOOR SLOPES NOTE (ANSI/ APSP/ ICC -5) - THE SLOPE OF THE FLOOR FROM THE SHALLOW END WALL TOWARDS THE DEEP AREA SHALL NOT EXCEED A 1:7 INCLINE TO THE POINT OF THE FIRST SLOPE CHANGE. - CHANGES IN THE SLOPE BETWEEN SHALLOW AND DEEP AREAS SHALL BE AT A MINIMUM WATER DEPTH OF 2 FT. 9 IN. AND BE AT LEAST 6 FT. FROM SHALLOW END, EXCEPT AS SPECIFIFIED IN PARA. 6.3 ANSI/APSP/ICC-5 "SHALLOW END DETAILFOR BEACH AND SLOPING ENTRIES". - THE SLOPE OF THE FLOOR SHALL NOT EXCEED A 1:3 INCLINE FOR DEEPER AREA AFTER 1:7 INCLINATION. POOL LIGHT & EQUIPOTENT BONDING 100W OR 300W LIGHT 12V UNDERWATER MINIMUM DISTANCE FROM 4' FROM WATER'S EDGE TO JUNCTION BOX, TO BE PROVIDED BY SWIM SPA CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR JUNCTION BOX #8 COPPER BOND WIRE CONTINUOUS AROUND POOL LIGHT NICHE #8 COPPER BOND WIRE, BONDED TO EXTERNAL LUG ON LIGHT NICHE, CONTINUOUS FROM NICHE TO SWIM SPA EQUIPMENT TRANSFORMER TO EQUIPMENT 3/4" CONDUIT FROM JUNCTION BOX TO PANEL, BY GENERAL CONTRACTOR 3/4" CONDUIT & WIRE FROM TRANSFORMER TO PANEL, BY GENERAL CONTRACTOR #8 GREEN COATED COPPER BOND & 1" CONDUIT WIRE, BONDED TO INTERNAL LUG ON LIGHT NICHE, COATED WITH 3M COMPOUND CONTINUOUS FROM NICHE TO JUNCTION BOX 8"5'-0" 4'-0"1'-0"5' IS MINIMUM DISTANCE FROM WATER'S EDGE TO TRANSFORMER, TO BE PROVIDED AND INSTALLED BY GENERAL CONTRACTOR 680-21 NEC (A) JUNCTION BOXES AND ENCLOSURES FOR TRANSFORMERS OR GROUND- FAULT CIRCUIT INTERRUPTERS.: 5. LOCATED NOT LESS THAN 4 IN. (102 MM), MEASURED FROM THE INSIDE OF THE BOTTOM OF THE BOX, ABOVE THE GROUND LEVEL, OR POOL DECK, OR NOT LESS THAN 8 IN. (203 MM) ABOVE THE MAXIMUM POOL WATER LEVEL, WHICHEVER PROVIDES THE GREATER ELEVATION 1-#8 SOLID BARE COPPER BOND WIRE WITH APPROVED CLAMPS 4" TO 6" BELOW SUB-GRADE BOND TO ALL EQUIPMENT OF INGROUND POOLS & AND ALL PARTS LISTED IN NEC 680.26 (B). CONNECTIONS TO BONDED PARTS SHALL BE MADE IN ACCORDANCE WITH 2017 NEC SECTION 250.8. 1-#8 SOLID BARE COPPER BOND WIRE ATTACHED TO THE POOL REINFORCING STEEL OR COPPER CONDUCTOR GRID OF CONDUCTIVE POOL SHELL AT A MIN. OF FOUR (4) POINTS UNIFORMLY SPACED AROUND THE PERIMETER OF THE POOL. 18" MIN. - 24" MAX. ENTIRE PERIMETER WATER LINE POOL SHELL EQUIPOTENTIAL BONDING DETAIL (2017 NEC SEC 680.26 (B) 2(b)) 4" 3000 PSI CONCRETE AT 28 DAYS 6X6-10/10 W.W.M. OR FIBERCRETE IN CONCRETE 1/4" W x 1/2" D TOOLED JOINT AROUND PERIMETER OF DECKDECK SLOPE 2% MIN./4% MAX 6" NOMINAL WATERLINE TILE 3/8" EXPOSED AGGREGATE OR MARSITE FINISH SEE POOL/ SPA REINFORCEMENT DETAILS 3000 PSI CONCRETE AT 28 DAYS POOL/ SPA CONC. DECK (TYP.) DETAIL TYP. POOL-SPA SECTION SPA SEAT/ BENCH SEE TYPICAL POOL DETAIL POOL WATERLINE 4'-0" MAX. WATER DEPTH4'-6" MAX.COMPACTED SOIL (2000 PSF MIN.) SPA DECK POOL WALL DEPTH PER PLANDOUBLE LAYER OF #3 REBAR EACH WAY (REFER REINF. SCHEDULE TABLE FOR REBAR SPACING) SPA WATERLINE POOL SPA 8"-12" TYP. (10" MIN. FOR POOL DEPTH > 6FT.) HANDHOLD SHALL BE PROVIDED AROUND THE POOL EDGE IN ANY AREA WHERE THE WATER DEPTH EXCEEDS 4 FT. AS PER ANSI/ APSP -5 SECTION 17.1 POOL DECK 18" MAX. RAISED (WHERE APPLICABLE) SPILLWAY BETWEEN POOL & SPA (WHERE APPLICABLE)20" MAX.#3 REBAR @ 12" O.C. EA WAY, 18" MIN. SPLICE 03SHEET : MAXIMUM AVERAGE WALL DEPTH 5'-8" 6'-7" 6'-10" 7'-1" 7'-5" #4 REBAR (24"MIN. SPLICE) 18" 18" 16" 14" 12" #3 REBAR (18" MIN. SPLICE) 12" 10" 9" 8" 6" REINFORCEMENT SPACING (O.C. EACH WAY) TABLE: REINFORCEMENT SCHEDULE POOL STAIRS (TYP.) DETAIL HANDHOLD SHALL BE PROVIDED AROUND THE POOL EDGE IN ANY AREA WHERE THE WATER DEPTH EXCEEDS 4 FT. AS PER ANSI/ APSP -5 SECTION 17.1 TYPICAL POOL/ SPA WALL AND FLOOR DETAIL 2" MINIMUM COVER EXCEPTION: ROPE AND FLOATS INSTALLED IF LESS THAN 4'-6" DEEPR 6"2'-9" EXCEPT FOR SLOPING ENTRIES 4'-0" 3000 PSI CONCRETE AT 28 DAYS 38" EXPOSED AGGREGATE OR MERSITE FINISH WATERLINE6" NOMINAL WATERLINE TILE SEE REINFORCEMENT SCHEDULE 6'-0" MIN. TO SLOPE CHANGE POOL DECK (2) #3 CONT. REBAR @ TOP OF POOL BEAM WATERLINE NOTE: POOL BEAM NOT DESIGNED FOR ADDITIONAL LOADS. REFER POOL/ SPA DETAIL POOL DECK 10"1'-0"TYPICAL POOL BEAM DETAIL REFER POOL/ SPA DETAIL POOL/ SPA IN FLOOD HAZARD AREAS OTHER THAN COASTAL HIGH HAZARDS ARAS AND COASTAL A ZONES: 1) PROVIDE 8" THICK (MIN.) POOL/ SPA WALL & FLOOR UNLESS NOTED OTHERWISE. 2) REFER SHEET 02 FOR FLOOD HAZARDS AREA NOTES. [ABOVE DETAIL VALID ONLY WHEN THE ELEVATION OF THE ACCOMPANYING POOL/ SPA DECK OR GRADE IS AT OR ABOVE (BFE + 1 FT) OR DFE WHICHEVER GREATER; FOR OTHER CONDITIONS, CONTACTOR SHALL CONSULT WITH THE ENGINEER] 6" THICK (MIN.) POOL/ SPA WALL & FLOOR FOR POOL NOT IN THE FLOOD HAZARDS AREA UNLESS NOTED OTHERWISE. SEE NOTES BELOW IF POOL/ SPA TO BE INSTALLED ON FLOOD HAZARDS AREA. (CONTRACTOR TO VERIFY) POOL/ SPA FLOOR & WALL THICKNESS NOTE: SEE POOL/ SPA WALL & FLOOR THICKNESS NOTE (THIS SHEET) SEE SPA FLOOR THICKNESS NOTE (THIS SHEET) REVISION 2: REVISION 1: DESIGN DATE: SCALE: NTSCONTRACTOR:PROJECT ADDRESS:PREMIER POOLS AND SPAS1905 PROMENADE WAYJACKSONVILLE FL 32207KINGSLEY 77 19TH ST, ATLANTIC FL 3223305/19/2023 DATE DATE RJ/IAThis item has been electronically signed and sealed by Craig E. Gunderson, P.E. on date below using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.PROJECT NO. 2312848 DRAWN BY:CA CERT. #30782FLORIDA ENGINEERING LLC4161 TAMIAMI TRAIL, UNIT 101PORT CHARLOTTE, FLORIDA 33952(941) 391-5980FLEng.comOrders@FLEng.comPUMP (TYP) SUCTION OUTLET (TYP) PVC TEE SIZED TO MATCH LARGER PIPE 8 FEET PER SECOND MAXIMUM (TYP) 3 FEET PER SECOND WITH BOTH SUCTION OUTLETS FLOWING (TYP) PIPE VELOCITY SKIMMER WITH EQUALIZER AND NO SUCTION OUTLET (NO MAIN DRAIN) LISTEN SUCTION OUTLET REQUIRED (DRAIN POT & GRATE) VENT THROUGH LID 18"MAXSKIMMER WITH EQUALIZER A SINGLE LISTED CHANNEL OUTLET SHALL BE CONSIDERED ACCEPTABLE IF THE SIZE OF THE PERFORATED AREA IS 3" OR GREATER IN WIDTH AND 31" OR GREATER IN LENGTH. CHANNEL OUTLET TO SINGLE PUMP SINGLE UN-BLOCKABLE CHANNEL OUTLET TO TWO PUMP SINGLE UN-BLOCKABLE DUAL OUTLETS ON DIFFERENT PLANES (ELEVATION OR PLAN VIEW) DUAL OUTLETS ON DIFFERENT PLANES MINIMUM DISTANCE 3 FEET APART (PIPE CENTERLINES) SUCTION OUTLET (TYP) PARALLEL TO ONE PUMP DUAL OUTLETS IN THREE OR MORE OUTLETS IN PARALLEL TO SINGLE PUMP MINIMUM DISTANCE 3 FEET BETWEEN OUTERMOST OUTLETS (PIPE CENTERLINES) IN PARALLEL ECCENTRICALLY TEPPED PIPING THREE OR MORE OUTLETS SUCTION OUTLET (TYP) MINIMUM DISTANCE 3 FEET APART (PIPE CENTERLINES) PARALLEL TO DUAL PUMPS IN PARALLEL DUAL OUTLETS IN THREE OR MORE OUTLETS IN PARALLEL TO SINGLE PUMP MINIMUM DISTANCE 3 FEET BETWEEN OUTERMOST OUTLETS (PIPE CENTERLINES) IN PARALLEL SYMMETRIC PIPING THREE OR MORE OUTLETS MINIMUM DISTANCE 3 FEET APART (PIPE CENTERLINES) PARALLEL DUAL OUTLETS TO TWO PUMP THREE OR MORE OUTLETS IN PARALLEL TO SINGLE PUMP MINIMUM DISTANCE 3 FEET BETWEEN OUTERMOST OUTLETS (PIPE CENTERLINES) IN PARALLEL LOOPED PIPING THREE OR MORE OUTLETS SKIMMER WITHOUT SUCTION OUTLET (NO MAIN DRAIN) PIPE SIZED TO MAXIMUM FLOW RATE OF SKIMMER OR SYSTEM. ADD SKIMMERS FOR ADDITIONAL FLOW, AS SKIMMER FLOW RATES WILL VARY VENT THROUGH LID SKIMMER VENT THROUGH LID LISTED SUCTION OUTLET (GRATE & FRAME) LISTED SUCTION SUMP (MAIN DRAIN POT) HYDROSTATIC RELIEF VALVE (WHEN NEEDED) SUCTION LINE COLLECTION TUBE GUNITE OR SHOTCRETE (CONCRETE) PLASTER POOL SURFACE TYPICAL SUCTION OUTLET MAIN DRAIN - FRAME, GRATE & POT DETAIL D MIN.DMIN.1.5 *DMIN.DD MIN.DMIN.1.5 *DMIN.D1.5 *DMIN.DMIN.DMIN.DDMIN.1.5 *DMIN.D GENERAL NOTES: (a) D= INSIDE DIAMETER OF PIPE (b) ALL DIMENSIONS SHOWN ARE MINIMUMS (c) A BROKEN LINE (- - -) INDICATES SUGGESTED STP CONFIGURATION OPTION C OPTION A OPTION B OPTION D MAIN DRAINS PLUMBING METHODS: 04SHEET :