Loading...
Jandy Pro Series JXi HEATER_19 anPc -- � qySeries 1i' INSTALLATION AND OPERATION MANUAL Jandy Pro Series JXi TM Gas -Fired Pool and Spa Heater Models 200, 260, 400 INSTRUCTIONSIF THESE •T FOLLOWED DAMAGE,WARNING A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY. - •INJURY,O- FOR YOUR SAFETY. This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by thejurisdiction in which the product will be installed where such state or local requirements exists. In the event no such state or local requirement exists, the installer or maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation can create carbon monoxide gas and flue gases which can cause serious injury, property damage, or death. For indoor installations, as an additional measure of safety, Zodiac Pool Systems, Inc. strongly recommends installation of suitable carbon monoxide detectors in the vicinity of this appliance and in any adjacent occupied spaces. Improper installation and/or operation will void the warranty. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS • Immediately switch off main gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Page 2 Jantly® Pro Series, JXi'" Gas Fired Pool &Spa Heater Installation &Operation Manual Table of Contents Section 1. General Information ....................... 3 1.1 Technical Assistance .......................................... 3 1.2 Warranty.............................................................3 1.3 Consumer Information and Safety ...................... 3 1.4 General Operation Description ........................... 3 1.5 Specifications..................................................... 4 1.6 Dimensions.........................................................4 1.7 Certification Codes and Standards ..................... 5 1.8 Heater Components ........................................... 5 Section 2. Getting Started ................................ 6 2.1 Package Contents .............................................. 6 2.2 Required Equipment ........................................... 7 2.2.1 Tools...................................................................................7 2.2.2 Materials.............................................................................7 Section 3. Location Requirements .................. 8 3.1 Clearances......................................................... 8 3.2 Outdoor Installation ............................................ 9 3.2.1 Anchor Bracket Installation ............................................... 10 3.3 Indoor and Outdoor Shelter Installation.............11 12.3.1 Combustion Chamber Assembly ...................................... 3.3.1 Combustion Intake Air Supply...........................................11 27 3.3.2 Exhaust Venting............................................................... 12 3.3.3 Indoor and Outdoor Shelter Exhaust Conversion ............. 13 3.3.4 Indoor and Outdoor Shelter Exhaust Termination ............ 14 3.3.5 Precautions Against Common Venting ............................. 14 3.3.6 Inspection and Replacement 29 7.3.2 of Existing Vent System with New Components ............... 14 Section 4. Gas Connections ..........................15 29 4.1 Supply Gas Requirements ............................... 15 4.2 Inlet Gas Pressure Test .................................... 16 4.3 Gas Offset Pressure Test ................................. 16 4.3.1 Connect the Digital Differential Manometer ...................... 17 4.3.2 Gas Offset Pressure Adjustment ...................................... 17 4.4 Special Precautions for LP Gas ........................ 18 Section 5. Water Connections .......................18 30 5.1 Pump Sizing ..................................................... 19 5.1.1 Manual Bypass Valve ....................................................... 19 5.1.2 Pump Sizing for New Pool Construction: ......................... 19 5.1.3 Pump Sizing for Replacement in an Existing Pool:.......... 19 5.2 Plumbing Connections ..................................... 20 5.2.1 Reversing Plumbing Connections .................................... 20 5.2.2 Optional Water Inlet Piping ............................................... 20 5.3 Water Pressure Switch Adjustment .................. 21 5.4 Check Valve Installation ................................... 22 5.5 Pressure Relief Valve Installation ..................... 22 5.5.1 Install pressure relief valve kit # R0336101 ...................... 22 5.6 Auxiliary Components, Chlorinators, 36 9.5.2 Ozone Generators, and Sanitizing Chemicals. 23 Section 6. Electrical Connections ................. 24 6.1 Service Access ................................................. 25 6.2 Main Wiring Connections ................................. 25 6.3 Input Voltage and Conversion .......................... 25 6.4 Bonding............................................................ 26 Section 7. Optional Remote Controls........... 26 7.1 Connecting to a Remote Pool -Off -Spa Selector 12.2 Cabinet Assembly Spare Parts List (3 -Wire Connection) ......................................... 27 7.1.1 Configure the Control Panel: ............................................ 27 7.2 Connecting to an AquaLink® Control System 12.3.1 Combustion Chamber Assembly ...................................... 41 or Remote TSTAT (2 -Wire Connection)............ 27 7.2.1 Install the Remote TSTAT:................................................ 27 7.2.2 Configure the Control Panel: ............................................ 27 7.3 "Smart" Communication via RS -485 ................ 28 7.3.1 To Restore Heater Control Panel Functionality After Connecting to an External Controller .................................... 29 7.3.2 To return functionality to RS: ............................................ 29 Section 8. Operating Instructions ................. 29 8.1 IMPORTANT SAFETY INFORMATION............ 29 8.1.1 WHAT TO DO IF YOU SMELL GAS ................................. 29 8.2 First -Time Start -Up Procedure ......................... 29 8.2.1 OPERATING INSTRUCTIONS ........................................ 30 8.2.2 If Ignition Is Unsuccessful ................................................. 30 8.3 TO TURN OFF GAS TO THE HEATER ........... 30 8.4 Normal Operation ............................................. 30 8.5 Operating the Controller ................................... 32 8.5.1 Setting up Heater Options ................................................ 32 8.5.2 Operating the Heater........................................................ 33 8.6 Shutting Down the Heater ................................ 33 Section 9. Maintenance .................................. 34 9.1 Water Chemistry ............................................... 34 9.1.1 Saturation Index............................................................... 34 9.2 Swimming Pool Energy Saving Tips ................. 35 9.3 Winterizing........................................................35 9.4 Spring Start-up ................................................. 35 9.5 Inspection and Service ..................................... 36 9.5.1 Guidelines for Homeowner Inspection: ............................ 36 9.5.2 Guidelines for Professional Inspection: ............................ 36 Section 10. Troubleshooting ........................... 37 10.1 Common Problems ........................................... 37 10.2 Service Diagnostic Messages .......................... 38 10.3 Ignition Control LED Service Codes ................. 38 Section 11. Professional Service and Maintenance .......................... 39 Section 12. Spare Parts .................................... 39 12.1 Major Components ........................................... 39 12.2 Cabinet Assembly Spare Parts List and Exploded Parts Diagram ........................... 40 12.3 Heat System Spare Parts List and Exploded Parts Diagrams .......................... 41 12.3.1 Combustion Chamber Assembly ...................................... 41 12.3.2 Burner Assembly..............................................................42 12.4 Water System Spare Parts List and Exploded Parts Diagrams .......................... 43 12.5 Electrical System Spare Parts List and Exploded Parts Diagrams ......................... 44 Jandy® Pro Series, JXi' Gas -Fired Pool & Spa Heater Installation & Operation Manual Page 3 Section 1. General Information This manual provides installation and operation instructions for the Jandy Pro Series JXi pool and spa gas heater product line. 1.1 Technical Assistance Web: www.jandy.com Phone: 800.822.7933 1.2 Warranty This heater is sold with a limited factory warranty. Details are included with this heater. Make all warranty claims to a Zodiac® dealer or directly to the factory. Claims must include the heater serial number and model (this information can be found on the rating plate), installation date, and name of the installer. Shipping costs are not included in the warranty coverage. 1.3 Consumer Information and Safety The heater is designed and manufactured to provide many years of safe and reliable service when installed, operated, and maintained according to the information A WARNING Improper installation or maintenance can cause nausea or asphyxi- ation from carbon monoxide in flue gases which could result in severe injury, or death. For indoor installations, as an additional measure of safety, Zodiac Pool Systems, Inc. strongly recom- mends the installation of suitable Carbon Monoxide detectors in the vicinity of this appliance and in any adjacent occupied spaces. A WARNING The following "Safety Rules for Hot Tubs," recommended by the U.S. Consumer Product Safety Commission, should be observed when using the spa. Consult heater operation and installation instructions for water temperature guidelines before setting tem- perature. • Spa or hot tub water temperature should never exceed 104°F (40°C). One hundred degrees Fahrenheit (100°F [38°C]) is consid- ered safe for a healthy adult. Special caution is recommended for young children. • The drinking of alcoholic beverages before or during spa or hot tub use can cause drowsiness which could lead to uncon- sciousness, and subsequently result in drowning. • Pregnant women take notel Soaking in water above 102°F (38.5°C) can cause fetal damage during the first three (3) months of pregnancy (which could result in the birth of a brain-damaged or deformed child). If pregnant women are going to use a spa or hot tub, they should make sure the water temperature is below 100°F (38°C) maximum. 1.4 General Operation Description Read the installation and operation instructions completely before proceeding with the installation. The warranty does NOT cover damage caused by improper assembly, installation, operation or field modification. Also, damage to the heat exchanger by corrosive water is NOT covered by the warranty. NOTE: Keep this manual in a safe place for future reference when inspecting or servicing the heater. in this manual and the installation codes referred to throughout. Be sure to read and comply with all warnings and cautions. • The water temperature should always be checked with an ac- curate thermometer before entering a spa or hot tub. Temperature controls may vary by as much as 1 F°/1 C°. • Persons with a medical history of heart disease, diabetes, cir- culatory or blood pressure problems should consult their physician before using a hot tub or spa. • Persons taking any medication which induces drowsiness (e.g., tranquilizers, antihistamines, or anticoagulants) should not use spas or hot tubs. • Prolonged immersion in hot water can induce hyperthermia. • Hyperthermia occurs when the internal body temperature reaches a level several degrees above the normal body tem- perature of 98.6°F (37°C). Symptoms include dizziness, fainting, drowsiness, lethargy, and an increase in the internal body tempera- ture. The effects of hyperthermia include: • Lack of awareness of impending hazard • Failure to perceive heat • Failure to recognize need to leave spa • Physical inability to leave spa • Fetal damage in pregnant women • Unconsciousness resulting in a danger of drowning The blower draws air and fuel through specially designed burner transferring the heat to the water. Exhaust gases orifices, delivering a precise mixture to the burner, are then directed through a duct where it is vented to the located inside the sealed combustion chamber. Water atmosphere. flows through the heat exchanger, which surrounds the Page 4 Jandy® Pro Series, JXi'" Gas -Fired Pool & Spa Heater Installation & Operation Manual 1.5 Specifications INSTALLATION LOCATION* SUPPLY GAS NATURAL GAS NG CERTIFIED INDOOR/OUTDOOR LIQUID PROPANE (LP) CERTIFIED INDOOR (US ONLY) / OUTDOOR / COVERED SHELTER GAS PIPE HEATER GAS VALVE CO N N E CTI ONt NATURAL GAS (NG) 3/4" NPT LIQUID PROPANE (LP) 3/4" NPT INLET GAS SUPPLY PRESSURE Min 4.0" WC Max 14.0" WC NATURAL GAS (NG) LIQUID PROPANE (LP) GAS VALVE OFFSET PRESSURE# NATURAL GAS (NG) 2" WC 2" WC LIQUID PROPANE (LP) WATER PIPE/HEATER CONNECTION NATURAL GAS (NG) PVCICPVC 2" unthreaded Jandy Pro Series threaded union LIQUID PROPANE (LP) T WATER FLOW RATE Min 30 gpm (76 Ipm) Max 100 gpm (454 Ipm) NATURAL GAS (NG) LIQUID PROPANE (LP) WORKING WATER PRESSURE Min Max NATURAL GAS (NG) 2 Psi 50 psi LIQUID PROPANE (LP) EXHAUST VENT CONNECTION SIZE (CATEGORY I)§ NATURAL GAS (NG) Model 200: 6 " • Model 260: 7 " Model 400: 8 " LIQUID PROPANE (LP) EXHAUST VENT CONNECTION SIZE (CATEGORY III) NATURAL GAS (NG) See Section 3.3.2 LIQUID PROPANE (LP) ELECTRICAL SUPPLY NATURAL GAS (NG) 120 VAC 240 VAC LIQUID PROPANE (LP) HIGH ALTITUDE NATURAL GAS (NG) Appliances are normally derated when installed at high elevation. This is not necessary with the JXi heater because it has a special venturi-type combustion system which self -compensates for changes in barometric pressure. Air flow through the blower inlet pulls the correct flow of gas into the burner regardless of air density. JXi heaters are CSA certified for elevations of up to 4,500 feet above sea level. At elevations above 4,500 ft., the heater BTU output can be expected to be reduced by 4% for every 1,000 feet over 4,500 feet above sea level. LIQUID PROPANE LP (LP) * Indoor installation is not recommended for liquid propane heaters. Review Special Precautions for liquid propane heaters (Section 4.4) Any changes to the heater, gas controls, air orifice, gas orifices, wiring, or tFor gas pipe size requirements see Section 4 improper installation may void the warranty. If change is required to any of $All readings must be taken while the heater is operating the above; contact your local Jandy distributor, visit www.jandy.com or call technical support at 800.822.7933. § Use type B double-wall gas vent, per table 13.1(a) NFPA 54 1.6 Dimensions 26.5" (67 cm) 24 c (63 cm) 16" (40.6 cm) Dimensions are identical for ali heater models Versa Plumb®Inlet 7 ..C+^W O F- o'� � Inlet - ll (4;c n) � � � � � • II�4I 10.13" 5.6" (26 cm) (14 cm) I 22.1" (56 cm) 5.1" -� (13 cm) 21.6" (55 cm)� 35.4" (90 cm) Figure 1. General Dimensions Jandy' Pro Series, JXi" Gas-Fired Pool & Spa Heater I Installation & Operation Manual"LeIM6-i;IIV—Page 5 1.7 Certification Codes and Standards DESIGN CERTIFIED COMPLIANT NATIONAL CODES USA CSA (Canadian Standards Association) ANSI® Z21.56 California South Coast Air Quality Management District's (SCAQMD) Rule 1146.2 National Fuel Gas Code NFPAO 541ANSI Z223.1 Pay particular attention to the chapter addressing Venting of Equipment CANADA CSA 4.7 Natural Gas and Propane Installation Code CANICSA-13149.1 Minimum combustion air requirements MUST be followed for proper and safe operation. Failures may occur when only the minimum combustion air openings are used. All Jandy Pro Series heaters must be installed in accordance with the local building and installation codes as per the utility or Authority Having Jurisdiction (AHJ). In the absence of local codes, please refer to the latest edition of the national codes for installation. JXi pool and spa heaters meet or exceed the requirements of energy conservation regulations such as those in states that have disallowed the use of continuously lit pilot type ignition sources. 1.8 Heater Components J Header Rear f.d e O Flue Temperature Sensor Monitors temperature at the exhaust flue. Ii excessive temperatures are detected, combustion will stop and a fault will be displayed. ®' Hot Sulfate Igniter When current is passed through the ceramic material of the igniter it will achieve temperatures great enough to initiate combustion of the airtfuel mixture. O Ignition Control Provides energy for ignition, monitors flame quality and controls the gas valve. Upon call for heat, the blower is activated to purge the combustion chamber. Electrical power is then applied to the hot surface igniter. When ignition temperature is attained, the gas valve opens and ignition occurs. If stable flame is detected the igniter will power down. If stable flame is not detected the control system will close the valve to prevent further gas release. If a total of 3 ignition attempts fail an ignition fault is displayed. O, High Limit Switches Prevent water of excessive temperatures from being discharged from the heater. If either switch, one at the heat exchanger first pass 57°C and one at the heat exchanger outlet 65°C, senses excessive temperature, the gas valve will close and combustion will stop. ®Indicates a safety control equipped to protect internal components and extend the fife of the heater. h - �i Oe PooVSpa Water Temperature Control. Senses water temperature by _ _ means of a thermistor. Heater will operate to attain and maintain the water temperature according to the heater settings. Two separate thermostat settings are supported, typically used to set pool and spa temperatures. O Water Pressure Switch Senses whether or not water is available to the heater by measuring back pressure at the ®header inlet. If insufficient pressure is detected, the display will indicate a "Check Flow" fault and combustion will stop. O Gas Valve Controls gas flow into the burner. Enables flow when the temperature control calls for heat and all safety controls enable operation. It also regulates gas pressure to -2" WC (Water Column) below the air pressure at the blower inlet. Necessary pressure regulation cannot be accomplished with common (positive pressure) gas valves. Oh Combustion Blower and Air Orifice Draws in air and fuel gas creating an air/fuel mixture that is passed through the burner for combustion. The fan will operate for several seconds before flame initiation and after the flame is extinguished to purge the combustion chamber for a clean bum and to expel any residual exhaust gas. O Air Pressure Switch Monitors the vacuum (negative pressure) within the blower housing. This switch verifies that air is ®flowing through the combustion system by sensing pressure. If air flow is inadequate, combustion will stop and a fault will be displayed. Page 6 Jandy® Pro Series, JXi' Gas -Fired Pool & Spa Heater I Installation & Operation Manual Section 2. Getting Started Install the JXi in accordance with the procedures in this manual, local codes and ordinances, and in accordance with the latest edition of the appropriate national code. See Section 1.7. If the heater is to operated in below freezing conditions it should be installed in a protected outdoor shelter. See Section 3.3 All gas-fired products require correct installation to ensure safe operation. The requirements for pool heaters include the following: 2.1 Package Contents Before completely unpacking the unit please inspect carton for damage. In addition please check the carton JX1400N IGNITION, DIRECT IGNITION 399,000 FEATURES JXI, US ALTITUDE: —0-11-110 - 1c 50"FT0.3T2m1.BTU.uO,1 m-i.I-4 �1 Oft 0 0.mwawwa.soortnanroLi� NAT BRD.0 .... Fl1EL- NNATURA L GAS SERIAL NO: E15XJ1000 11 IS IIIIIIIIIIIIIIIIIII III milli llllllllllllllllllllll l • Field assembly (if required) • Appropriate site location, clearances and flooring see Section 3 • Sufficient combustion and ventilation air • Properly sized gas meter and piping • Proper electrical wiring • Sufficient water flow This manual provides the information needed to meet these requirements. Review all applications and installation procedures before continuing the installation. label to ensure that you have the correct fuel type and BTU rating for your application. `• t! Item Description Qty. 1 JXI Heater 1 2 VersaPlumb Sweep Elbow 1 3 2" Universal Union Tailpiece 2 �aNlTloN-1 DIRECT IGNITION � 399,000 FEATURrm JXI, US ALTITUDE: cs,�c.wn.aro.m.•mu... "o •nsoo FT t+.3Tzm>, eTu..ro.� NAT.BRD.# FUEL Pik s IAL�o : E 15XJ 1232 IIIIii Iiiiiiiiliiilliillill ifflilIl lIIiIIIlililim i Item Description Qty. 4 2" Universal Union Cap 1 5 2" Universal Union O-ring 3 6 2" Universal Union Nut 3 NOTE: 1 EA of item 4, item 5 and item 6 will come pre-installed at the horizontal manifold inlet. at ;O Jandy® Pro Series, JXi- Gas -Fired Pool & Spa Heater Installation & Operation Manual Page 7 2.2 Required Equipment Please ensure that the following equipment is available to the installer at the time of installation. 2.2.1 Tools Safety Eyewear Adjustable Wrench pqpo 0000 Gloves 3/16" Hex Key Voltage Meter PVC Pipe Cutter 2.2.2 Materials Supplied by Installer Phillips Screwdriver Channel Locks Power Drill Please ensure that all materials used during the installation are in accordance with local codes or the authority having jurisdiction (AHJ) requirements. If you have any questions regarding the materials that need to be used during this installation please call the Zodiac customer service center at 1-800-822-7933. Indoor installations will require additional venting and exhaust conversion materials which are outlined in detail in Section 3.3 NOTE: Required materials may differ from the materials listed. Be sure to confirm with all local and national codes before beginning the installation. Flathead Pipe Wrench Screwdriver Digital Differential Manometer Tape Measure GASSUPPLIES ELECTRICAL PLUMBING SUPPLIES SUPPLIES Appropriately sized Gas 120 or 240 VAC PVC Piping Piping (see Section 4.1) Manual Gas Shut Off Valve Conduit Elbow/ PVC Cement Conduit connector. Gas Union Teflon Tape Cap Leak Solution 1/16" Hose "T" JFIejConduit 1/8" - 1/16" Barbed Adapter 1/16" Flexible Hose Page 8 Jandy® Pro Series, JXi- Gas -Fired Pool & Spa Heater Installation & Operation Manual Section 3. Location Requirements The JXi heater is shipped from the factory with an exhaust vent configured for outdoor installation. The heater is also design -certified for indoor installations in the United States and for outdoor shelter installations in Canada. See Section 3.3 for details. Location of the heater below or above the pool water level affects operation of its water pressure switch. See sections 5.3 for more information. 3.1 Clearances The heater must be installed in a location that allows clearances for maintenance and inspection. Minimum distances from combustible surfaces must also be maintained. All criteria given in the following sections reflect minimum clearances as stated in the national standards. However, each installation must also be evaluated, taking into account prevailing local conditions such as wind speed and direction, proximity and height of obstructions that may block ventilation, and proximity to public access areas. .) Combustible LLSurface 6 in (15 cm) Service Clearance TOP: 36 in (45 cm) FRONT: 18 in (22.5 cm) USA 24 in (30 cm) Canada required per CSA 8149.1, section 4.14.2. NOTE: Clearances are manufacturer's tested values. These are given as minimum values. Where local and national codes apply, and if the clearance values specified in the applicable codes are different than those listed in this manual, use the greater value to ensure safest operation. Figure 2. Clearances NOTE: If the heater is to be operated in below freezing conditions it should be installed in a protected outdoor shelter. CAUTION When pool equipment is located below the pool surface, a leak from any component can cause large scale water loss or flooding. Zodiac Pool Systems, Inc., cannot be responsible for such water loss or flooding or resulting damage. Service Clearance: 36 inches (45 cm) from top of heater for removal of top panel. 18 inches in the us and 24 inches (30 cm) in Canada from one of either the front or rear panels. Combustible Surfaces: Each heater face requires a 6 inch (15 cm) clearance from combustible surfaces. Although it is not advisable, the heater base can be placed on a combustible surface for operation. However, do not install the heater on carpet. :4 ,400%414 Jandy® Pro Series, A" Gas -Fired Pool & Spa Heater I Installation & Operation Manual Page 9 3.2 Outdoor Installation Locate the heater: • On a level Solid Surface • 5 ft (1.5 m) from inner pool edge unless separated by a permanent solid barrier, i.e. a wall or fence • In an open area, not under a deck or other structure • Away from doors windows or louvers that connect in any way to occupied or inhabited areas of the building. Do not locate the heater below or adjacent to any doors, windows, louvers, grills, etc., which connect in any way with an inhabited area of a building, even though the,, access might be through another structure (e.g., a garage or utility room). L— h�. The area under an overhang must be open on three sides to prevent combustion gases from being diverted into living areas through doors, windows, or gravity inlets NOTE: In Canada the top of the exhaust vent must beat least 10 feet (3 m) from any building opening.. • Away from rainwater runoff • Away from potential sprinkler water intrusion • So that the top of the heater is at least 3 feet (1 m) below any overhang • So that the top surface of the heater is at least 3 feet (1 m) above any forced air inlet within 10 feet (3 m) If the heater is installed close to a structure, protect it from rain water runoff with rain gutters on the roof or other measures. Be sure to divert rain water runoff away from heater In the United States install the heater so that there is at least a three (3) foot (1 m) clearance between the bottom of the overhang to the top of the heater exhaust vent. Do not install the heater with the top of the vent assembly within 4 feet (1.22 m) horizontally, 4 feet (1.22 m) below or less than 1 ft (300 mm) above of any opening into a building. Local codes and installation requirements may vary. in Canada, install the heater so that the top of the vent is at least .t 10 feet (3.0 m) from any building opening. The top surface of the heater must be at least 3 feet (1 m) above any forced air inlet, or intake ducts located within 10 feet (3.0 m) horizontally Locate the heater on a level surface in an open, unroofed area. Do not install the heater under a deck. min. 5 ft (1.5 m) — — — — — — —� unless the heater is separated from the pool by a solid fence, wall or other permanent solid barrier. Do not locate the heater near sprinkler The heater must be installed on a level, solid, and firm surface or platform. systems that could spray water on it. Although it is always advisable to install the heater on a non-combustible Water from sprinklers can damage surface, the JXi-series has been CSA -certified for installation on solid, controls and electronic components. firm, and level combustible surfaces. DO NOT INSTALL ON CARPET. Figure 3. Location Requirements A WARNING United States Canada Do not install the heater with the top of the vent assembly within 4 feet Do not install the heater with the top of the vent assembly within (1.22 m) horizontally, 4 feet (1.22 m) below or less than 1 ft (300 mm) 10 feet (3.0 m) of any opening into a building. Local codes and above of any opening into a building. Local codes and installation installation requirements may vary. requirements may vary. Page 10 Jandy® Pro Series, JXi" Gas -Fired Pool & Spa Heater ( Installation & Operation Manual 3.2.1 Anchor Bracket Installation Anchor brackets do not come standard with the M if you require the anchor brackets for your installation please order kit #R0593400. Anchor brackets should be installed in any circumstance where the heater may be subject to natural risks such as extreme weather or earthquake. In Florida, the heater is required to be securely fastened to the equipment pad to meet the applicable requirements of the Florida Building Code. Other jurisdictions may have similar requirements for extreme weather or other natural hazards. Check your local codes for details. 0 Using an adjustable wrench or equivalent tool loosen (DO NOT REMOVE) the retaining nut on the bracket. The upper and lower anchor bracket should be able to rotate freely about the retaining pin. IDSlide the bracket into the slot located at the lower corner of the heater base. ID Rotate lower anchor bracket into final position. Ensure that the lower anchor bracket is flush with the equipment pad surface and level. Anchor Bracket Upl Retaining Nut Retaining Pin Anchor Bracket Lower Concrete Equipment Pad ^ti `"' 1X1- Heater Base — Anchor Bracket Slot Concrete Screw ANCHOR BRACKET INSTALLATION SECTION VIEW LI 49 Tighten the retaining nut so that the anchor bracket assembly is secure. QDrill a hole in the concrete using the lower anchor bracket hole as a guide. It is advised that a hammer drill with an appropriate concrete drill bit be used. QPlace a screw in the hole and tighten to fasten the anchor bracket to the concrete pad. Do not over torque the screws. NOTE: Depending on the location of and access to the bracket, it may be necessary to mark the drill location using the lower anchor bracket hole as a guide. Remove the bracket from the heater, drill the hole and then reattach the bracket to the heater base. NOTE: Concrete screws are not provided in the anchor bracket kit. Use size 1/4" x 2-1/4" galvanized or plated concrete screws and washers. Jandr Pro Series, JXi" Gas -Fired Pool & Spa Heater I Installation & Operation Manual Page 11 3.3 Indoor and Outdoor Shelter Installation Due to the higher risks and hazards of liquid propane (LP) gas, Zodiac® does not encourage installation of LP gas heaters indoors. Please be sure to refer to Section 4.4. The heater is CSA design -certified for indoor installations in the US and for outdoor shelter installations in Canada. Please keep in mind the service and combustible surface clearances from Section 3.1 when selecting an installation location. You will also need to make considerations for intake combustion air see Section 3.3.1 3.3.1 Combustion Intake Air Supply Greater Than 10 ft. (3 m) i 2 ft. (61 cm) Min. Height required J ! for any roof surface within 10 ft. ( 3m) ----------------------_---- Storm----------------- -- Storm Collar— UseApproved Rook Jack In Canada the installation must be in accordance with the latest edition of CAN/CSA 8149.1 Within 12 in. (30.5 on All outdoor shelter and indoor installations must have uninterrupted openings to outside air for combustion and ventilation. Do not, under any circumstances, install this product in an indoor location which does not provide combustion air to the appliance from outside the building. Within 12 in. (30.5 cry and exhaust venting see Section 3.3.2. In addition, when pool equipment is installed indoors, appropriate containment measures and drains should be considered for the prevention of property damage in the event of an equipment leak. NOTE: An outdoor shelter is an unoccupied enclosure which does not communicate directly with occupied areas. Zodiac Pool Systems, Inc., does not recommend US outdoor shelter installations that depend on internal air for combustion. f Tj i_ I I Minimum Net Free Open Area" Combustion Openings Minimum pitch per 12 in. of pipe: 1/4 in (6.35 mm) 50 int JX 200 323 cm2 65 int JX260 419 cm2 100 int JX 400 645 cm2 Multiply required 'if air passes through: opening above by Horizontal Duct 2 I Screens or Metal Louvers 1.5 Wood Louvers 4 n For garage installation, heater base must be 18 in (46 cm) above the floor. Figure 4. Indoor and Outdoor Shelter Installation The "Minimum Net Free Open Area" information from Figure 4 is not applicable in installations where exhaust fans or blowers of any type are used. Any equipment which exhausts air from the room where the heater is installed can deplete the combustion air supply or reverse the natural draft action of the venting system. This could cause flue products to accumulate in the room. Additional air must be supplied to compensate for such exhaust. Consult a professional engineer to ensure that installations where exhaust fans or blowers are used are designed and installed in accordance with all applicable local and national installation codes. In addition, the heater must be completely isolated and protected from any source of corrosive chemical fumes or corrosive vapors (i.e chlorine or hydrochloric acid). A WARNING Do not store any chemicals, cleaners, or other corrosive material near combustion air openings or in the room. Avoid locating appliance vents in the vicinity of combustion air openings. Failure to prevent corrosive materials from mixing with combustion air can result in reduced heater life and unsafe heater operation. I As outlined in the latest edition of ANSI® standard Z223.1 (NFPA® 54), the heater — Listed Vent Cap location must be properly vented to provide sufficient air supply for proper combustion. FF When combustion air is supplied directly through an outside wall, each opening 3 ft. (91.5 cm) Minimum should have a minimum free area of 1 square Above Highest Outlet Point inch per 4,000 BTU/h (1.2 kW) input of the total input rating of all appliances in l the enclosed area. If combustion air must pass through horizontal ducts, each opening should have a minimum free area of 1 square inch per 2,000 BTU/h (1.2 kW) input of the total input rating of all appliances in the enclosed area. Details can be found in Figure 4. f Tj i_ I I Minimum Net Free Open Area" Combustion Openings Minimum pitch per 12 in. of pipe: 1/4 in (6.35 mm) 50 int JX 200 323 cm2 65 int JX260 419 cm2 100 int JX 400 645 cm2 Multiply required 'if air passes through: opening above by Horizontal Duct 2 I Screens or Metal Louvers 1.5 Wood Louvers 4 n For garage installation, heater base must be 18 in (46 cm) above the floor. Figure 4. Indoor and Outdoor Shelter Installation The "Minimum Net Free Open Area" information from Figure 4 is not applicable in installations where exhaust fans or blowers of any type are used. Any equipment which exhausts air from the room where the heater is installed can deplete the combustion air supply or reverse the natural draft action of the venting system. This could cause flue products to accumulate in the room. Additional air must be supplied to compensate for such exhaust. Consult a professional engineer to ensure that installations where exhaust fans or blowers are used are designed and installed in accordance with all applicable local and national installation codes. In addition, the heater must be completely isolated and protected from any source of corrosive chemical fumes or corrosive vapors (i.e chlorine or hydrochloric acid). A WARNING Do not store any chemicals, cleaners, or other corrosive material near combustion air openings or in the room. Avoid locating appliance vents in the vicinity of combustion air openings. Failure to prevent corrosive materials from mixing with combustion air can result in reduced heater life and unsafe heater operation. I Page 12 I= Jandy® Pro Series, JXi- Gas -Fired Pool & Spa Heater Installation & Operation Manual 3.3.2 Exhaust Venting When the M heater is installed indoors or in an outdoor shelter it can be vented as a Category I or Category III appliance. In either case the vent pipe sizing must be in accordance with the specifications listed in Table 1. • Category I: Appliance operates with a negative vent static pressure, a vent gas temperature that avoids excessive condensate production and will vent vertically terminating at the roof. • Category III: Appliance operates with a positive vent static pressure, a vent gas temperature that avoids excessive condensate production and can be vented horizontally terminating at a side wall. • Do not terminate heater vents near air conditioning or air supply fans which could pick up exhaust flue products, such as carbon monoxide and other hazardous effluent, and return them inside the building. • Vent pipe type and material must be carefully selected and depends on the type of installation. • Do not locate the vent terminal where exhaust flue products could strike against building materials and cause degradation. • Vent opening should be well away from landscaping or other obstructions that would prevent free air flow to and from vent terminal. • Do not terminate vent under decks, stairs, or car ports. • Do not use the appliance to support the vent pipe. • Vent piping must be supported with no low spots or sagging which could allow condensate to collect. • Horizontal runs must be sloped upwards away from the heater to a vent terminal at a minimum of 1/4" per horizontal foot (2 cm/m). See Figure 4. • Install the vent pipe so it can expand and contract freely with temperature changes. • Do not run the heater vent into a common vent with any other appliance. • It is recommended that vent runs over 18 feet be insulated to reduce condensation and use a condensate trap in the vent run close to the heater, especially in cold climate installations. A WARNING Vent pipe materials, sizing, and installation must be as required by the National Fuel Gas Code NFPA 54/ANSI® Z223.1 or the Canadian Installation Codes for Gas Appliances CAN/CSA-13149.1. Undersized pipe can result in inadequate venting and oversize pipe can result in vent condensation. Improper selection of vent pipe material, incorrect sizing of the pipe, and incorrect installation of vent piping can result in release of combustion products to the indoors. This can cause serious injury or death by Carbon Monoxide poison- ing or asphyxiation. A WARNING Improper installation or maintenance can cause nausea or asphyxia- tion from carbon monoxide in flue gases which could result in severe injury or death. For indoor installations, as an added measure of safety, Zodiac Pool Systems, Inc. strongly recommends installation of suitable carbon monoxide detectors in the vicinity of this appliance and in any adjacent occupied spaces. Incorrect design and installation of heater vents and ducts can result in personal injury, damage to property, or death. To avoid such hazards, the heater must be installed only by a qualified professional service technician. CODES* 111111110- National Fuel Gas code ANSI®Z223.1 (NFPA® 54) CAN/CSA-13149.1 CATEGORY STATIC STATIC PRESSLOCATION STACK TEMP. CONDENSATE TERMINATION PIPE SIZING SPECIAL GAS VENT LENGTHt MODEL PIPE SIZE (VERTICAL OR HORIZONTAL) ( Negative High Minimal Roof 200 6 in (15 cm) N/A 260 7 in (18 cm) N/A 400 1 8 in (20 cm) N/A (( Positive High Minimal Roof or Side wall 200 4 in (10 cm) 50 ft (15 m) 260 4 in (10 cm) 70 ft (21 m) 400 4 in (10 cm) 70 ft (21 m) *Ensure that you are referencing the latest edition and pay special attention to the chapter addressing "Venting of Equipment'. tFor each elbow installed, reduce the run length by 12 feet (3.7m) Table 1. Vent Pipe sizing Requirements Jandy® Pro Series, JXi- Gas-Fired Pool & Spa Heater Installation & Operation TWIM1W Page 13 3.3.3 Indoor and Outdoor Shelter Exhaust Conversion For both Category I and Category III vent types the heater must first be converted to indoor exhaust type. In order to complete the conversion you will need to order exhaust conversion R -Kit R0711900. 0 Remove two screws securing the exhaust grill to the exhaust grill backplate. ID Remove exhaust grill. t3' Remove the two screws securing the rain shield to the exhaust backplate. 0 Remove Rain Shield. 10 Remove the remaining two screws securing die exhaust backplate to the exhaust outlet. 0 Remove the exhaust grill backplate. (' Using two #10 thread cutting screws secure the vent adapter from R -Kit R0711900 to the exhaust outlet. 4D If venting for Category I, install an appropriate vent pipe increaser to accommodate the correct pipe size from Table 1. Secure to the vent adapter using the screw clamp. When the installation requires horizontal venting in excess of what is allowed for Category I installations or calls for horizontal discharge, the JXi may be installed with a Category III venting system. Vent the heater either vertically or horizontally using A1294C stainless steel components. Consult manufacturers such as Z -Flex® or Heat Fab® to obtain approved components. Venting materials must comply with UL® 1738 for Category III, Special Gas Vent. In Canada, the venting materials must be ULC 5636 compliant. 0 If venting for Category III, install appropriate vent pipe from Table 1. Secure to the vent adapter using the screw clamp to ensure a proper seal. Exhaust Grill Double check that there are no possible leak paths between joints. If a leak path is identified or suspected it can be sealed using red RTV 600° F rated silicone adhesive. � for CIII ategarY When using parts or materials from other manufacturers please be sure to follow the manufacturers instructions completely to ensure harmonious function. IMPORTANT NOTE In the Commonwealth of Massachusetts, additional requirements, covered in document CMR 248 5.00, which supersede some of the require- ments of ANSI Z223.1 (NFPA 54) apply to Side Wall Horizontally Vented appliances. If installing this product using an approved side-wall hori- zontal vent system in the Commonwealth of Massachusetts, be sure to adhere to these additional requirements. These requirements include verbiage that says that the property owner is to ensure that Carbon Monoxide Detectors are installed in the vicinity of the appliance and also on all levels of the dwelling in which the appliance is installed. For further instructions, contact Technical Support at 800.822.7933. Page 14 NORM, Jandy® Pro Series, JIM` Gas -Fired Pool & Spa Heater Installation & Operation Manual 3.3.4 Indoor and Outdoor Shelter Exhaust Termination Category I: Appliance must be vented vertically and terminate at the roof. Vent must terminate at least 2 feet (610 mm) above any objects within 10 feet (3.05 m). Termination must pass through a properly installed and approved roof jack, a properly sized storm collar and an listed vent cap. See Figure 4. Category III: Appliance can be vented vertically to terminate at the roof or vented horizontally to terminate at 4 ft (1.2 m) min. a side wall. Side wall vents must be installed and located in accordance with the National Fuel Gas Code NFPA® 54 / ANSI® Z223.1 or the Canadian Natural Gas and Propane Installation Code CAN/CSA-B 149.1. In addition some local installation codes may have requirements that exceed those of the national codes. The product must be installed in accordance with the codes being enforced by the local Authority Having Jurisdiction (AHJ). Refer to CSA B149 for requirements specific to Canadian installations. Check local installation codes which may require greater minimum � -- distances from windows and doors to be maintained. VENT TERMINATION (Suggested Z -Vent parol 2SVSRTF) 12 in (30 cm) min. Figure 5. Side Wall Vent Termination 3.3.5 Precautions Against Common Venting �a 3 ft (0.9 m) min. --" If dim. is less than 10 ft (3.0 m) Seek the assistance of a Registered Professional Engineer for proper design of a common venting system. Zodiac Pool Systems, Inc. does not recommend using a common vent to vent multiple appliances through a common duct. However, if no other option is deemed available by the installer, each appliance must have its own vent temperature limit switch. All vent limit FORCED AIR INLET switches must be wired in series so as to prevent any appliance from firing in the event of a blocked vent. An outside draft inducer must be installed to pull and create negative pressure in the vent system. Refer to ANSI® Z223.1 or in Canada CAN/CSA B 149.1 for more information on common venting multiple appliances. Do not connect vent systems of different categories to the same venting system. 3.3.6 Inspection and Replacement of Existing Vent System with New Components When replacing an existing pool heater with the JXi, it is recommended that a new appropriate venting system is installed with the new heater. However, if the existing venting system must be used, be sure to carefully inspect the existing system to ensure that it is in good condition and appropriate for the JXi heater. Replace any parts that are not in serviceable condition before completing the installation. Jandy® Pro Series, JXi`" Gas -Fired Pool & Spa Heater I Installation & Operation Manual Page 15 Section 4. Gas Connections Gas piping installation must be in accordance with the latest edition of ANSI Z223.1 and all local codes. In Canada, the installation must be in accordance with CAN/ CSA B 149.1 and all local codes that apply. The heater must be isolated from the gas supply piping system by closing the individual manual shut off valve during any pressure testing of the gas supply piping system at test pressure greater than or equal to 1/2 psi (3.50a). CAUTION [Permanent damage to the gas valve will occur if the installation procedures are not followed correctly. 4.1 Supply Gas Requirements A WARNING The JXi pool and spa heaters are designed for use with either natural gas or LP gas. Check the rating plate on the front of the combustion chamber to be sure that the heater is designed to use the type of gas being supplied. CONVERTING THIS HEATER FOR USE WITH ANY OTHER FUEL TYPE IS NOT RECOMMENDED BUT, WHEN NECESSARY, SHOULD ONLY BE PERFORMED BYA LICENSEDAND QUALIFIED PROFESSIONAL, AND ONLYAFTER CONTACTING ZODIAC POOL SYSTEMS FOR THE PROPER INSTRUCTIONS AND CONVERSION KIT. All questions should be directed to the Zodiac customer service center at 1-800-822-7933 Table 2. Supply Gas Pipe Size Requirements • Refer to Table 2 for correct gas inlet piping length from the gas meter to the heater. • Check the gas meter to make sure it will supply enough gas to the heater and any other appliances using the same gas supply. If unsure, contact your local gas utility to confirm. • Install a manual gas shutoff valve outside the heater body for service and safety. Never install the shutoff valve inside the body of the heater. • Install a sediment trap and union ahead of the gas controls and outside the heater body. See Figure 6. • Do not use a restrictive gas cock. ATTENTION Do not use flexible appliance connectors on any gas connections unless the connector is CSA approved for outdoor installation, and is marked with the BTUH capacity (which must be equal to or greater than the heater rated input) and the type of gas (Natural or LP). Also, any flexible connectors, such as CSST buried underground must be certified for underground installation and meet all applicable codes. Please note, use of flexible connector still requires the installation of a sediment trap per NFPA 54. See Figure 6. NOTE: The gas line from the meter is usually larger than the gas valve. Therefore, you will need to reduce connecting pipe as necessary. Make this reduction as close to the heater as possible. GAS SUPPLY INLET MANUAL SHUT-OFF L VALVE GAS PIPE 1 UNION PIPE MINIMUM NIPPLE TO HEATER 76- INLET SFDIMENTTRAP IOVABLE CAP Figure 6. Manual Shut-off Valve and Sediment Trap Maximum Equivalent Pipe Length Natural Gas at 1050 btu per cubic foot Propane Gas at 2500 btu per cubic foot 3/4" 1" 1-1/4" 1-1/2" 2" Model NG LP NG LP NG LP NG LP NG LP JXi400 5 ft 20 ft 30 ft 60 ft 11011 260 ft 230 ft 560 ft 600 ft 600 ft JXi260 15 ft 40 ft 60 ft 150 ft 230 ft 590 ft 490 ft 600 ft 600 ft JXi200 30 ft 70 ft 1 100 ft 1 240 ft 1 380 ft 600 ft 600 ft • Numbers are for natural gas (0.60 Sp. Gr.) based on 1/2 inch (3.45 kPa) water column pressure drop. Check supply pressure with a manometer, and local code requirements for variations. • Check supply pressure and local code requirements before proceeding with installation. • Consider pipe fittings when determining gas pipe sizing. For every elbow used add three (3) feet to straight pipe length. • Table shows the minimum supply gas pipe size required. Larger pipe size can be used if required by local code or if desired. • It is critical that the incoming gas supply pressure at the heater is within the maximum and minimum pressure requirements. If the range of acceptable supply pressure is not provided, the gas supply system to the heater must be modified to meet pressure requirements. Table 2. Supply Gas Pipe Size Requirements • Refer to Table 2 for correct gas inlet piping length from the gas meter to the heater. • Check the gas meter to make sure it will supply enough gas to the heater and any other appliances using the same gas supply. If unsure, contact your local gas utility to confirm. • Install a manual gas shutoff valve outside the heater body for service and safety. Never install the shutoff valve inside the body of the heater. • Install a sediment trap and union ahead of the gas controls and outside the heater body. See Figure 6. • Do not use a restrictive gas cock. ATTENTION Do not use flexible appliance connectors on any gas connections unless the connector is CSA approved for outdoor installation, and is marked with the BTUH capacity (which must be equal to or greater than the heater rated input) and the type of gas (Natural or LP). Also, any flexible connectors, such as CSST buried underground must be certified for underground installation and meet all applicable codes. Please note, use of flexible connector still requires the installation of a sediment trap per NFPA 54. See Figure 6. NOTE: The gas line from the meter is usually larger than the gas valve. Therefore, you will need to reduce connecting pipe as necessary. Make this reduction as close to the heater as possible. GAS SUPPLY INLET MANUAL SHUT-OFF L VALVE GAS PIPE 1 UNION PIPE MINIMUM NIPPLE TO HEATER 76- INLET SFDIMENTTRAP IOVABLE CAP Figure 6. Manual Shut-off Valve and Sediment Trap Page 16 I= Jandy® Pro Series, JXi' Gas -Fired Pool & Spa Heater Installation & Operation Manual 4.2 Inlet Gas Pressure Test Before operating the heater it is necessary to test the input gas pressure to ensure that it falls within the required range as outlined in Table 3. NG LP INLET GAS (NATURAL GAS) I (LIQUID PROPANE) PRESSURE INCHES W.C. MAX 10.5 14 MIN 4 4 • All readings must be made while heater is operating. • Relying on any reading taken while heater is off may result in poor performance and difficulty in operation. Table 3. Supply Gas Input Pressure Requirements Pull gas inlet grommet away from heater body panel. Remove one screw and the gas valve access panel. Remove 1/8" NPT plug using a 3/16" Hex Key. Install a 1/8" to 1/16" barbed adapter. Connect positive manometer lead to barbed adapter. Inlet gas pressure must be taken while the heater, and if possible, all other gas burning appliances supplied by the same gas delivery system, are operating. If the gas supply pressure is less than required, check for an undersized pipe between the meter and the heater, a restrictive fitting, or an undersized gas meter. If needed contact the local gas utility company for assistance. Once proper inlet pressure has been confirmed, shut off gas supply. 4.3 Gas Offset Pressure Test Before operating the heater it is necessary to test the offset gas pressure to ensure that it falls within the required range of -0.2rr WC (Inches Water Column) +/- 0. V WC. This reading must be taken with the heater running using a digital differential manometer. • Verify the manual gas shutoff valve is open. • Remove the heater rear panel to expose the gas valve. • Remove manometer, hose and barbed fitting from the gas valve. • Apply joint compound to the NPT plug and reinstall. • Before operating the heater, test the gas supply system and all connections for leaks using a soap solution. Do not use an open ® ®gyp flame to test for leaks. p • Reinstall the gas valve access panel. ® � �� r � Screw • Secure the gasi inlet grommet at heater side panel. Gas Valve Access Panel Gas Inlet Grommet 1/8" NPT to 1116" Barbed Adapter 1/8" NPT Plug Connect Hose to Barbed Adapter m G ®®® ~L— Conned Hose to Positive (+) Manometer Port View With Side Panel Hidden 0 Remove the four screws securing the panel to the heater body. 10 Lift and remove panel. Set aside a safe distance from the work area. 0 Verify that the gas valve control is in the "ON" position. Gas Valve Control Switch C NOTE: The rear panel is the main body panel closest to the gas inlet. This may appear to be the front panel if the user interface was moved to accommodate a left side water connec- tion. For instructions on moving the user interface see 5.2.1. Jandy® Pro Series, JXi" Gas -Fired Pool & Spa Heater Installation & Operation Manual Page 17 4.3.1 Connect the Digital Differential Manometer. 0 Connect a tee to the hose running from the fan inlet post on the blower to the gas valve vent port. Connect one leg of the tee to the gas valve vent port. 19 Connect the third leg of the tee to the positive (high pressure) side of the digital differential manometer. 0 Remove the 1/8" NPT plug from the gas valve manifold port (labeled "PRESS" "TAP") using a 3/16" Hex Key. 0 Install a 1/8" to 1/16" barbed adapter. 0 Connect a hose from the barbed adapter to the negative (low pressure) side of the digital differential manometer. • Start the heater and record the gas offset pressure. • Measurement should be -0.2" WC (Inches Water Column) +/- 0.1" WC. • If the offset pressure is incorrect an adjustment can be made. See Section 4.3.2 for details • If no adjustment is required, remove manometer, hoses, tee and barbed fitting from the gas valve. • Reconnect the hose from the Fan Inlet Port to the Gas Valve Vent Port. • Apply joint compound to the NPT plug and reinstall at the gas valve manifold port (labeled "PRESS" "TAP"). • Before operation, test the complete gas supply system and all connections for leaks using a soap solution. Do not use an open flame to test for leaks. 4.3.2 Gas Offset Pressure Adjustment If the offset pressure is incorrect an adjustment can be made to bring the offset pressure within the required range. Prior to making any gas valve adjustments: • Ensure that the inlet gas pressure from Section 4.2 is within the specified range. • Ensure that the manometer has been connected in accordance to steps a -f in Section 4.3.1. • Ensure that all hoses, barbed fittings plugs and caps are securely in place and not leaking. • With the heater running read and record the offset pressure displayed on the manometer. If an adjustment is still required: 0 Remove the gas valve sealing cap. 0 Using a flat head screwdriver turn the plastic adjustment screw as follows: To Increase Offset Pressure: Turn the adjustment screw 1/4 turn clockwise. To Decrease Offset Pressure: Turn the adjustment screw 1/4 turn counter clockwise. • Once the proper gas offset pressure has been achieved. Securely reinstall the gas valve sealing cap. • Shut down the heater at the user interface. • Remove manometer, hoses, tee and barbed fitting from the gas valve. GAS VALVE VENT PORT o e FAN INLET PORT 0 °T"JOINER — r + 0 POSITIVE— (High Pressure Port) ONEGATI' DIGITAL (Low Presses MANOMETER 0 Apply joint GAS VALVE MANIFOLD PORT LABELED compound to the 0 NPT plug and I reinstall at the gas a valve manifold port ID e (labeled "PRESS" "TAP"). • Before operation, _ test the complete gas supply system0�4 f Pressure Adjustment and all connections 18 for leaks using aDecrease Pressure soap solution. Do not use an open 0.Increase Pressureflame to test for(Omkwise) leaks. A WARNING Failure to replace the 1/8 inch NPT gas valve plugs on inlet, gas offset pressure ports, and cap on the manifold pressure adjustment screw, can result in property damage, severe injury, or death. CAUTION Some leak test solutions (including soap and water) may cause corrosion or stress cracking. Rinse the piping with water after testing. Page 18 Jandy® Pro Series, JXi" Gas -Fired Pool & Spa Heater Installation & Operation Manual 4.4 Special Precautions for LP Gas Under the same environmental conditions, liquid propane (LP) gas is more dense or heavier than air and will more readily collect or pool in enclosed areas if adequate ventilation is not provided. It is not recommended to install LP gas heaters in enclosed areas such as pits. Locate heaters a safe distance from LP gas cylinders and filling equipment. Consult the National Fuel Gas Code (NFPA® 54/ANSI0 Z223.1, latest edition), the Liquefied Section S. Water Connections Install pool system components with connections as illustrated in Figure 7. Any configuration other than as illustrated in Figure 7 can affect the operation of the water pressure switch. Locating the heater above or below the pool water surface can also affect operation of the water pressure switch. FILTER HEATER CHECK VALVE J (Always install a corrosion resistant check valve when any sanitation equipment, including erosion feeders and salt chlorination systems are install see section 5.4 for mon: details) SPA RETURN 91 Petroleum Gas Code (NFPA 58, latest edition), the Natural Gas and Propane Installation Code in Canada (CAN/CSA B149.1, latest edition), and any other local codes and fire protection authorities about specific installation restrictions in your area. For ALL installations the combustion air openings requirements and NFPA54 / ANSI Z223.1 MUST be followed for safe and proper operation. NOTE: When pool equipment is located below the pool surface, Zodiac Pool Systems, Inc. is not responsible for any large scale water loss, flooding or damage caused by a leak. CAUTION The pool equipment must be protected from back -siphoning of wa- ter. If there is any chance of back -siphoning, provide a check valve between the pool and the filter pump inlet. POOL/SPA PUMP 3 WAY VALVE - / SKIMMER MAIN DRAINS (Suction Outlet) POOL MANUAL BY-PASS DETAI RETURN USE WHEN FILTRATION RAl EXCEEDS 100 GPM FOR JANDY J HEATERS. REFER TO Th MANUFACTURER RECOMMENDATIONS IF USING DIFFERENT BRAND HEATE Figure 7. Typical Water Piping Configuration SPA DRAIN (Suction Outlet) a. MANUAL BYPASS VALVE Jandy® Pro Series, JXi' Gas -Fired Pool & Spa Heater Installation & Operation Manual Page 19 5.1 Pump Sizing The flow bypass within the heater manifold will accommodate flow rates delivered to the heater from a minimum of 30 gallons per minute (gpm) to a maximum flow of 100 gpm. CAUTION The system water pump must be capable of providing no less than 30 gpm of flow through the heater. Flow rates at less than 30 gpm may cause nuisance operation causing the heater to turn off or dam- age to the heater. %--Ai 200K BTU Heater ®®®JXi 260K BTU Heater —4s--JXi 400K BTU Heater --------JXi VersaFlolll Bypass Figure 8. Head Loss Chart 5.1.1 Manual Bypass Valve 20.0 18.0 16.0 14.0 d 2 12.0 4A J 10.0 >3 f6 4! 8.0 c Lo 6.0 G1 4.0 2.0 0.0 MODEL I MIN GPM (LPM) I MAX GPM (LPM) JXI 200 30 (114) 100 (379) JXI 260 30 (114) 100 (379) JXI 400 I 30 (114) I 100 (379) Table 4. Recommended Flow Rate Adjustment 1 -­-- I 20 30 40 50 60 70 80 90 100 110 Flow Rate (GPM) 9.0 8.0 7.0 H Q 6.0 CL O 5.0 O 7 4.0 V1 N L CL 3.0 c N 2.0 0 1.0 A manual bypass valve is to be installed in any system in • Adjust the valve to bring the flow rate within the which the pump flow exceeds 100 gpm to the heater. acceptable range. See Table 4. • Connect ball valve between water inlet and outlet. • Remove the valve handle to avoid tampering. See inset "a." in Figure 7. 5.1.2 Pump Sizing for New Pool Construction: When sizing a pump for the system, the head loss for NOTE: In order to properly establish head loss at flow for a filter, all system components must be added together when remember that a "dirty" filter can typically add 10 psi of additional determining the design flow rate. Component "Head head loss (23 extra feet of head). This must be considered when Loss at Flow" curves are available from equipment sizing a pump for a new pool system. manufacturers. 5.1.3 Pump Sizing for Replacement in an Existing Pool: If the JXi heater replaces a different model of heater, determine if the existing pump is capable of providing the minimum flow of 30 gpm. JXi heaters are high efficiency heaters. Heaters typical of this construction may have higher head loss characteristics than the one being replaced. CAUTION Heater failure due to insufficient water flow is not covered under war- ranty. See measurements in the Head Loss Chart. See Figure 8. Page 20 1= Jandy® Pro Series, A' Gas -Fired Pool & Spa Heater I Installation & Operation Manual 5.2 Plumbing Connections The heater has a standard 2 inch water manifold and coupling design. With this feature, only nominal two inch PVC or CPVC may be connected to the heater. However, 5.2.1 Reversing Plumbing Connections The Ai heater is shipped with the manifold on the right side by default. If necessary the water connections can be orientated to the left side by rotating the top panel of the appliance. NOTE: The electrical raceway, transformer, PIB, Ignition control and voltage selector board are all accessed through the default front panel. Special considerations should be made for service clearance, see Figure 2, before the final location and orientation of the appli- ance is determined. • Turn off all power to the heater at the breaker. • Ensure that the pump is off and will remain off for the duration of the procedure. 10 Remove the four black screws securing the heater top panel to the heater body. IDLift heater top panel. Be careful not to damage or apply undue stress to the user interface wiring. 19 Rotate the heater top panel 1800. • Place heater top panel securely on heater body. • Secure with the four screws removed in step "a" 5.2.2 Water Inlet Piping There are two options for water inlet connections on the JXi. Both configurations use the same water outlet to return heated water to the pool. Be sure to check flow rates as outlined in Section 5.1 and if necessary make provisions for and ensure sufficient space for the installation of a manual bypass valve as outlined in Section 5. L L The top inlet is intended for use with the Jandy Versa Plumb® sweep elbow. Plumbing in this configuration can increase hydraulic efficiency particularly when used in a system with other Versa Plumb compatible Jandy Pro Series Equipment. See Figure 9. Figure 9. Versa Plumb Heater Inlet by installing appropriate pipe adapters and two-inch pipe (supplied by the installer), any size existing pipe may be fitted to the heater. IJ • Restore power to the heater. • Return heater to normal operation. The sweep elbow also provides the advantage of its exclusive interface with the Zodiac AquaLink® RS temperature sensor. The side inlet is positioned at a 10 1/8" (255.7 cm) center height providing an ideal height for replacement unit or new construction plumbing. • Turn off all power to the heater at the breaker. • Turn off main gas supply to heater. • Ensure that the pump is off and will remain off for the duration of the procedure. • Do a dry fit test of cut pipe lengths in order to ensure proper seating of the union tailpiece and o -ring. Make adjustments to pipe length or positioning as needed. • Clean all adhesion surfaces with an appropriate NSF® approved all purpose cleaner/primer. • Slide the union nut onto the cut pipe length. or sweep elbow. Ensure proper nut orientation with threads directed towards the heater manifold. See Figure 10. • Use approved NSF adhesive to glue the tailpiece onto the cut pipe, or sweep elbow. NOTE: Zodiac Pool Systems, Inc. recommends Weld -On® 724TM PVC to CPVC Cement to glue Schedule 40 PVC. Jandy® Pro Series, JXi' Gas -Fired Pool & Spa Heater Installation & Operation Manualsow Page 21 Union Nut Sweep Elbow • o. ! Union Tailpiece Y Cut Pipe If O -Ring LEI' / Top Inlet Manifold Orifice Side Inlet Manifold Orifice • O -Ring I Drain Cap Union Nut -YY YY YY YY Cut Pipe •�I I p � 01. -- Union Tailpiece O -Ring Manifold Outlet Figure 10. Inlet Piping • Align Tailpiece and manifold orifice. • Secure to manifold with union nut hand tight only. Do not overtighten. Do not use pipe joint or thread tape. • If using the sweep elbow. Use approved NSF adhesive to glue the sweep elbow onto the cut pipe. • Repeat the above steps for the manifold outlet. Again paying special care to ensure proper seating of the union tailpiece o -ring. 5.3 Water Pressure Switch Adjustment. The water pressure switch is inside the heater jacket on the water connection side See Section 1.8, item "f'. The switch is preset at the factory for activation at 2 psi (14 kPa). The pressure switch setting must be adjusted If the heater is installed: • Below the surface level of the pool • More than two feet above the pool level • Where the pressure is measured at 1 psi or greater with the filter pump off Figure 11. Water Pressure Switch Adjustment • Install the union nut and drain cap with o -ring at the unused inlet on the heater manifold. Be sure that the o -ring is properly seated. Secure hand tight only. Do not overtighten. Do not use pipe joint or thread tape. • Return all valves to their operating positions. • Restore power to the heater at the breaker. • Turn on pump and inspect carefully for leaks. • Restore main gas supply. • Start the system and check for proper flow. • Return heater to normal operation. A WARNING To avoid an electrical shock hazard, which can result in serious injury or death, ensure that all electrical power to the system is turned off before approaching, inspecting or troubleshooting any leaking valves or plumbing that may have caused other electrical devices in the surrounding area to get wet. ■ Follow all filter manufacturer's instructions. Never attempt to assemble, disassemble or adjust the filter when there is pressurized air in the system. Starting the pump while there is any pressurized air in the system can cause the filter lid to be blown off, which can cause death, serious personal injury or property damage. Location of the heater above or below the pool water surface can also affect the operation of the switch. The factory installed switch can accommodate elevations of 6 feet above the pool water surface or 11 feet below pool water surface. If the heater water connections are outside this range Consult your local Zodiac® representative for recommendations. Set the heater control to "OFF". Remove seven screws securing the side panel to the heater body. • Remove the side panel to gain access to the water pressure switch. See Figure 11. • Turn the filter pump on and confirm that the pressure switch closes with a voltmeter. • If the switch does not close, check that all valves are open to the heater and that there are no restrictions in the line. You may also need to confirm flow rate from your pump as outlined in Section 5.1. CAUTION The water pressure switch should be adjusted to tum the heater off when the pump is off. Setting the switch to close at too low flow can damage the appliance. Adjust the switch to turn the heater off, not on. NOTE: It is recommended that a Pressure Release Valve (PRV) be installed prior to taking any of the steps below. Please see Section 5.5 for details. Page 22 Jandy® Pro Series, JXi`" Gas -Fired Pool & Spa Heater Installation & Operation Manual • Once an operational and correctly sized pressure switch has been confirmed, set the heater control to either POOL or SPA. Heater should start. • With your fingers, turn the adjustment sprocket very slowly clockwise until the heater goes off. • Slowly turn the pressure switch adjustment sprocket counterclockwise one-quarter turn. The heater should come back on. See Figure 11. • Check the adjustment by turning the filter pump OFF. The burner should shut off immediately. If 5.4 Check Valve Installation When any equipment is located below the surface of the pool or spa, back -siphoning can occur, which can draw water backwards through the circulation system. This can be particularly concerning if chemically treated water is allowed to flow back into equipment such as heaters, filters and pumps. Make sure any chemical feeder or chlorination system outlet lines are downstream of the heater and a positive seal noncorrosive check valve is installed between the sanitation equipment and the heater. Always install a check valve if there is sanitation 5.5 Pressure Relief Valve Installation A pressure relief valve (PRV) is recommended in all installations, and is mandatory in any installation in which the water flow can be restricted between the heater outlet and the pool/spa. A pressure relief valve may also be required by local codes. Be sure to check any applicable installation codes in your area to determine whether a pressure relief valve is required. A pressure relief valve is not supplied with the JXi heater. However, Jandy does offer a PRV Kit # R0336101. The following instructions are for use with this kit only. All 5.5.1 Install pressure relief valve kit # R0336101 • Turn off the electrical power to the heater. • Tum off the main gas supply to the heater. • If the heater has been operating, ensure you allow enough time for remaining water in the heat exchanger to cool down before beginning. It is recommended that protective gloves be worn during the entire procedure. • Make sure the filter pump is off and will remain off for the duration of the installation procedure. • If the heater is below the surface level of the water in the pool or spa, close all shut-off valves between the heater and the pool. U it does not, restart the filter pump and repeat the preceding step. Check the adjustment again. If you are still unable to successfully set your water pressure switch please contact your local Jandy distributor or call technical support at 800.822.7933. Additional information can be found at www.jandy.com. Return the temperature control to the desired temperature. equipment installed in the system. Do not install any shutoff valve in the piping between the heater outlet and the pool. A WARNING A check valve can interfere with the proper operation of certain Suc- tion Vacuum Release System (SVRS) products. To avoid possible entrapment hazard, serious injury, or death, make sure to review the operation/owners manual of your particular SVRS product before installing the check valve. other equipment installations need to be in accordance with the manufacturers instructions. The maximum working pressure of this heater is 50 psi. Be sure to take into consideration the maximum allowable pressure of the other components in the system when installing a PRV. Any pressure relief valve installed must comply with provisions of the standard described in ANSI® Z21.22 for the United Sates or CSA 4.4 in Canada. CAUTION Use Teflon® tape only on the threads of the pipe nipple attachment to the plastic manifold. Do not use pipe compound or pipe dope on threads or any part that comes into contact with the plastic manifold. These compounds may damage the manifold over a period of time. Q Remove drain plug from manifold and allow all water to drain from heat exchanger. 0 Locate the threaded boss on the outlet port of the manifold, and find the dimple at the center. IC N■ N1N■ ■ � �,� b �e TIP: Drilling a 118' diameter hole will help prevent thread damage. Jandy' Pro Series, JXi- Gas -Fired Pool & Spa Heater Installation & Operation Manual Page 23 0 Using the dimple to center the drill bit, drill a 1/4" diameter hole through the boss, taking care not to damage the surrounding plastic threads. TIP: Drilling a 1/8" diameter hole first will help prevent thread damage. 0 Each male connection should be first wrapped in 5-6 turns of Teflon' tape. _�;:v o � Teflon® Tape ¢¢¢' Discharge p OpOening L Pressure Relief 0 Assemble the threaded nipple, 0 Valve (PRV) reducing bushing, elbow and Threaded pressure relief valve. Make sure that Nipple all connections are snug. Do not 7Reducinguc overtl hten. Bushing 0 The final orientation of the pressure relief valve (PRV) will have the discharge opening facing away from the heater manifold. 0 Wrap the open end of the nipple in 5-6 turns of Teflon tape. © Install the pressure relief valve assembly at the heater manifold. 0 Make sure to get a sung fit. Do not overtight 0 The final orientation of the pressure relief w should be vertically aligned with the discharge c facing away from the heater manifold. ©Install a discharge pipe from the pressure rel discharge opening to a safe area. This is a preca to prevent the possibility of personal injury or p. damage in the event scalding water is discharge the pressure relief valve. Elbow 0Install the discharge pipe so that there is no trapped or standing water in the piping. Discharge piping must be facing down, terminating with a threadless nipple, no less than 6" from floor. Discharge piping must be open with no reducers or shut-off valves or other restrictions. To ensure the continued proper operation of the pressure relief valve, the valve should be tested once a year. To test, lift the lever with the circulation system running to ensure that water will pass through. When the lever is down, there should be no leaks from the outlet. 0 Threadless Discharge Pipe 6' Min. --------------------------------------round Level --------------•--------------------- 5.6 Auxiliary Components, Chlorinators, Ozone Generators, and Sanitizing Chemicals The M heater is manufactured with materials that are not compatible with high concentrations of ozone, chlorine, bromine, or other sanitizing chemicals. Heater damages caused by improper water chemistry or plumbing configurations are not covered by the Zodiac Pool Systems, Inc. warranty. All questions should be directed to technical support at 800.822.7933. Additional information can be found at www.jandy.com. Be sure to adhere to the following: • All sanitation equipment is to be installed as the last piece of equipment in the circulation system. • When ozone is used, install a mixing degas chamber, to prevent ozone and air from entering the heater. • When chemical feeders are used, install an in-line check valve between the heater and the feeder. • Wire any electrical sanitation equipment so that it cannot operate unless the filter pump is running. • Always follow pool chemical manufacturer's instructions when adding chemicals to pool. ill Page Z4 Jandy® Pro Series, JXi' Gas Fired Pool &Spa Heater Installation &Operation Manual Section 6. Electrical Connections Wiring connections must be made exactly as shown in the wiring diagram found on the inside of the heater door. The NEC and CEC also require that the equipment and/ or appliances associated with the pool water circulating system, including, but not limited to, pump motors and heaters, be bonded together as part of the equipotential bonding grid. Zodiac Pool Systems, Inc. provides a special labeled bonding lug on the manifold side of the heater to accommodate this requirement. All electrical connections and wiring must be done by a certified electrician only. Electrical wiring must also Ahmate 120V Wiring*TRANSiORME HEAVER NEUTRAL R R HEATER PIM SUPP Y HOT LY 13 E4VAC IVatwSelemUrdMW&R=daW. I I I j2 }II( +L:t7l ■1� M E'u� G� ■C'0. TERPI III I MR ()) UNIVERSAL CONTROL FACE (I�) MO7�oR5 (I) 8SIAIM COIUAIR FAW TEMP LOUVER GAS(I) PUMP VALVE (a) COMP/ 0 KN (h) 2SVAC VENT FL 7EMPIMIT E TEMP (q) (d) CCI (AA) VALVE 240* W USHE (f) (e) H6RESSI WATER REMOTE (464•F) WIFRFACEI HRIMtr PRESS SPA POOL COM ® OfE " UYLE UNIVERSAL ARROW sMFLO BIBK I i V CONTROLLER m GY-GRAY USER INTERFACE O - ORANGE rn o to � I R -RED II INTERFACE 2 D 1 W - WHITE � � n ' [D ' _TOPUMP RELAY FOR ---'0'[�-- W (FU CONTACTS pF USED) I LOUVER r r Factory Wired 24V STARTER UFUSED) LIMIT LIMIT 120V/240V SWITCH SNATCH 57'C 66. i135 -F) (150'F) Figure 12. JXi Connections/ Schematic Wiring Diagram be in accordance with the latest edition of the National Electrical Code® (NEC®), ANSI®/National Fire Protection Association® (NFPA®) 70, or in Canada, the Canadian Electrical Code (CSAR' C22.1) unless local code requirements indicate otherwise. The heater comes factory -wired for installation with 240 Volt, 60 Hz AC field electrical supply. If the use of 120 Volt, 60 Hz AC field electrical supply is required, You must first change the position of the voltage selector board on the power distribution board. See Section 6.3 for details IGNITION CONFROL GAS VALVE R !""I 1 u HOT SURFACE IGNITER ARROW sMFLO BIBK I C T O CUBK BR -BROWN m GY-GRAY PK O - ORANGE rn o to � I R -RED PK V - VIOLET 2 D 1 W - WHITE � n ' [D ' _TOPUMP RELAY I N I 0 42 (FU CONTACTS pF USED) I ' I Factory Wired 24V Factory Wired 120V/240V A WARNING CAUTION ELECTRICAL SHOCK HAZARD. This heater contains wiring that Label all wires prior to disconnection when servicing controls. Wiring carries high voltage. Contact with these wires may result in severe errors can cause improper and dangerous operation. injury or death. Verify proper operation after servicing. BK - BLACK BL - BLUE BR -BROWN G - GREEN GY-GRAY WATER O - ORANGE PRESS R -RED SNTCH V - VIOLET W - WHITE Y - YELLOW Y/BK-YELLOW WITH BLACK TRACE BBK- BLUE WITH BLACK TRACE GBK-GREEN WITH BLACK TRACE PK - PINK A WARNING CAUTION ELECTRICAL SHOCK HAZARD. This heater contains wiring that Label all wires prior to disconnection when servicing controls. Wiring carries high voltage. Contact with these wires may result in severe errors can cause improper and dangerous operation. injury or death. Verify proper operation after servicing. Jandy® Pro Series, JXi'" Gas-Fired Pool & Spa Heater Installation & Operation Manual Page 25 6.1 Service Access Remove the four screws holding the front heater panel in place to expose the raceway. 0 Locate the raceway lock release on the interior of the heater raceway. QUsing a screwdriver or comparable tool; press into the raceway release orifice until the raceway latch releases, and the raceway swings free. 0 Secure the raceway in place by lifting until the locking latch engag( 0 Push the tab on the locking latc to release. • Press raceway down and back until an audible click indicates that it is latched in position. • Replace heater front panel. 6.2 Main Wiring Connections The main wiring connections should be available externally to the heater at the time it is unpacked. Use flexible conduit to run the main power lines from the power source to the heater connections. No external junction box is required. NOTE: Before the raceway can be rotated for the first time a shipping zip tie must be cut. This zip tie is threaded at the raceway release point see item (a). While cutting this zip tie be sure not to damage or abrade any of the wires. • Ensure that all electrical power is shut off to the heater at the breaker. • Ensure that the filter pump is off and will stay off for the remainder of the procedure. • Follow applicable service access instructions from Section 6.1. QRun conduit and power lines from main power source to the heater side panel. QMake wire connections via wire nuts. 0 Push wire connections through the knockout into the heater body. Be careful not to damage or abrade any wiring during this procedure. Q Secure the conduit to the heater body panel at the knockout using a suitable conduit connector or elbow. NOTE: If the heater is converted to accept 120V, the "Hot" wire of the 120V power supply has to be connected to the black wire (ACH 1) on the power distribution board and the "Neutral" wire of the 120V power supply has to be connected to the red wire (ACN1) of the power distribution board.Please see Figure 12 for details. Page 26 Jandy® Pro Series, JXi- Gas -Fired Pool & Spa Heater Installation & Operation Manual 6.3 Input Voltage and Conversion The heater comes factory -wired for installation with 240 Volt, 60 Hz AC field electrical supply. If the use of 120 Volt, 60 Hz AC field electrical supply is required, You must first change the position of the voltage selector board on the power distribution board. • Ensure that all electrical power is shut off to the heater at the breaker. • Ensure that the filter pump is off and will stay off for the remainder of the procedure. • Follow service �ab � access instructions from Section 6.1. QLocate the power distribution board in the lower right hand section of the raceway. 10 Using scissors, clip the zip tie securing the voltage selector board into the power distribution board. 0 Remove and rotate the voltage selector board 180°. The printed message "FOR 120 VAC" will be displayed above the card connection pins. 10 Reinstall voltage selector board. 6.4 Bonding Zodiac Pool Systems, Inc., requires that the appliance be connected to a "bonding loop" that includes all electrical equipment in the system and on the equipment pad. Bonding lugs must be connected with a solid copper wire at least 8 AWG (6 AWG in Canada) or larger. Failure to do so will void the Zodiac Pool Systems, Inc. warranty. Additionally, in the United States the National Electrical Code® (NEC®) and in Canada the Canadian Electrical Code (CEC), require that all metallic components of a pool structure, including reinforcing steel, metal fittings X i.. NOTE: The voltage selector board is keyed so that it will fit in only one direction for either selected voltage (either side of the board). A WARNING ELECTRICAL SHOCK HAZARD. To avoid an electrical shock hazard, which can result in serious injury or death, ensure that all electrical power to the system is turned off before approaching, inspecting, or troubleshooting any leaking plumbing that may have caused electrical devices in the surrounding area to get wet. and above ground components be bonded together (forming an "equipotential bonding grid") with a solid copper conductor not smaller than an 8 AWG (6 AWG in Canada). CAUTION To prevent premature failure of the appliance resulting from stray voltages and voltage differentials, the heater must be bonded to other equipment which is part of the pool plumbing system with a solid copper wire not smaller in diameter than 8 AWG (6 AWG in Canada). Section 7. Optional Remote Controls The JXi heater controls can be wired for remote operation. All Zodiac® AquaLink® Control Systems will permit the heater to be operated by remote control. The instructions in the following sections should be used as a general guideline only. Please follow the instructions that accompany your selected control system thoroughly. If you are setting up a new pool or spa system, or if you have any questions about your heater control system, please call Jandy technical support at 800.822.7933. Electrical wiring must be in accordance with the latest edition of the National Electrical Code (NEC), ANSI®/ National Fire Protection Association® (NFPA70®), unless local code requirements indicate otherwise. Refer to Figure 12 for a complete diagram of wiring connections and terminals. Consult with Jandy Technical Support, 800.822.7933 for questions about installing non -Zodiac remote controls. Jandy' Pro Series, A' Gas -Fired Pool & Spa Heater Installation & Operation Manual PIV ENGL H Page 27 7.1 Connecting to a Remote Pool -Off -Spa Selector (3 -Wire Connection) Turn off the power to both the pool/spa control system and the heater unit. Follow applicable service access instructions from Section 6.1. Run the wires from the pool/spa control system through the low voltage knockout on the right or left hand side of the heater. 7.1.1 Configure the Control Panel: • Make sure the pool heater is OFF. • Press and hold MENU, then the POOL and SPA buttons for 5 seconds to access Service Setup mode. NOTE: The display will revert back to OFF after 1 minute since the last key press. • Connect the wiring from the pool/spa control system to the heater remote control terminal. See Figure 12 item "b". • Connect the three wires to Spa, Pool & Common terminals of the J6 terminal bar. • Reinstall front panel. • Restore power to the heater and the pool/spa control system. • Press MENU, REMOTE OFF (default remote) is displayed. • Use Up or Down to scroll through the Remote options until HI -LO -COM is displayed, then press MENU to select. • Press POOL or SPA to exit Service Setup mode. • Press Up or Down to display REMOTE. 7.2 Connecting to an AquaLink® Control System or Remote TSTAT (2 -Wire Connection) An interrupt (on/off-type) remote can be connected as a Remote TSTAT to turn the heater on or off but not perform any other function. When using this type of 7.2.1 Install the Remote TSTAT: • Turn off the power to both the pool/spa control system and the heater unit. • Follow applicable service access instructions from Section 6.1. • Run the wires from the pool/spa control system through the low voltage knockout on the right or left hand side of the heater. • Connect the wiring from the pool/spa control system to the heater remote control terminal. • Connect the two wires to Pool and Common (not Spa) on the J6 terminal bar. See Figure 12 item "b". • Reinstall panel. • Restore power to the heater and the pool/spa control system. 7.2.2 Configure the Control Panel: Make sure the pool heater is OFF. Press and hold MENU, then the POOL and SPA buttons for 5 seconds to access Service Setup mode NOTE: The display will revert back to OFF after 1 minute since the last key press. • Press MENU, REMOTE OFF (default remote) is displayed. connection, remember to set the heater control to "pool" or "SPA" and set the thermostat control to maximum. NOTE: If you install a time clock to control the filter pump operation, it is recommended that the time clock have its own low voltage (Fireman's) switch to turn off the heater before turning off the pump. The switch should shut off the heater about 15 minutes before the filter pump shuts off. This will allow for a more efficient operation by removing any residual heat contained in the heat exchanger back to the pool. CAUTION To avoid damage to the heater, do not connect the power supply of the heater to the output side of the clock if your time clock simply interrupts the high voltage power supply or has a high voltage output. Doing so will prevent the blower from purging the residual heat from the heater when the heater turns off. The blower must be allowed to run for 45 seconds after the heater shuts off. Use Up or Down to scroll through the Remote options until REMOTE TSTAT is displayed, then press MENU to select. Press POOL or SPA to exit Service Setup mode. Press POOL or SPA to adjust the set point to the maximum 104°F (40°C). Page 28 - Jandy® Pro Series, JXi' Gas -Fired Pool & Spa Heater I Installation & Operation Manual 7.3 "Smart" Communication via RS -485 To provide "smart" communication between the JXi and a power center board (PCB) (AquaLink® RS, AquaLink PDA, and AquaLink Z4) through a red four -pin RS485 connector, your PCB must have the appropriate firmware. To determine the REV of the AquaLink RS PCB firmware in your system, refer to Table 5. COMPONENTS REV MMM REV N OR EARLIER OR LATER RS485 One (1) set of Two (2) sets of CONNECTORS four (4) four (4) JVA SOCKETS Located on top of Located on bottom of 24 VAC board board RELAY SOCKETS 10 total sockets. Eight 11 total sockets. 24 VDC (8) located on bottom, All located on two (2) on top of board bottom of board. Table 5. AquaLink RS Power Center Board Identifying Features If your PCB firmware is REV MMM or earlier: Connect via a 2 -wire connection. See Section 7.2 for details. Connection to I; Spa Side i; Sensors and + NA Sockets I; Relay Sockets Controller: Switch Heater i 24 VAC 24 VDC RS485 i i, + E t Connectors FVii J H W z U7 7 a ` 0M00000000 000- ----------- i ---------------- I..:.. _ ti¢ Relay Sockets Relay Sockets 24 VDC24 VDC Figure 14. PCB with firmware REV MMM or lower Do not connect more than two (2) wires to any of the terminals in the Control System when connecting peripheral devices. If connecting the heater to the control system creates this situation, then a Multiplex PCB Kit, which includes the Multiplex Board (part # 6584) must be used. Call Jandy Technical Support at 800.822.7933 with any questions. NOTE: Only an AquaLink® RS System with firmware revision "N", or higher, will support the heater interface. Refer to Table 5 along with Figure 14 and Figure 15 to determine the REV of your system's firmware. If it is "N" or higher, continue with these procedures. If it is MMM or lower, follow the procedures in Section 7.2 for connecting to a remote TSTAT. NOTE: Only a PDA System with firmware revision 4.1, or higher, will support the heater interface. Figure 13. Wiring the JXi to a Zodiac' Remote If your PCB firmware is REV N or higher: • Turn off the power to both the heater and the controller. • Open the power center enclosure and remove the tront dead panel. Connection to Spa Sensors Controller. Side I and RS485 Connectors Switch Heater e-• ,% i i f i tYi i 6-66660000 000 '.-El fJ' El.Jw ti Nam ..: �. ..� ` ❑ ,, d i t.............. ....... .... w ioW Relay Sockets i NA Sockets € Relay Sockets 24 VDC 24 VAC 24 VDC Figure 15. PCB with firmware REV N or higher • Use 22 gauge 4 -conductor wire to run between the heater and the RS control and match the wire color order. See Figure 13. • The wires coming from the heater can be "doubled up" on the red terminal bar with the four wires from the indoor controller. • Check all wiring, then apply power to both the heater and the control system. Verify operation in either Service or Auto mode. Refer to your Control System manual for operating instructions. When the heater is connected to an external controller, all functionality of the heater control panel is disabled, therefore heater functions can be controlled only from the controller. Jandy® Pro Series, JXi'" Gas-Fired Pool & Spa Heater I Installation & Operation Ma MeRM.PW Page 29 7.3.1 To Restore Heater Control Panel Functionality After Connecting to an External Controller • Turn power to the heater ON. The heater display shows: JANDY REMOTE ONLINE PUSH MENU TO DISABLE. • Press MENU to remove message and restore functionality to the heater control panel. 7.3.2 To Return Control Back to a Connected External Controller • Turn power to the heater OFF then back ON. • Press and hold MENU for 5 seconds to access Setup Mode. Section 8. Operating Instructions Follow the instructions outlined below to start the heater. Refer to the Lighting and Shutdown Instructions label on the inside lid panel of the heater. See Figure 17 All questions should be directed to technical support at 800.822.7933. Additional information can be found at www.jandy.com. 8.1 Important Safety Information Read Before You Start: • This appliance does not have a pilot light. It is equipped with an ignition device, which automatically lights the heater. Do NOT try to light the burners by hand. 8.1.1 What To Do If You Smell Gas • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the Fire Department. • Use only your hand to switch on or off the gas control switch. Never use tools. If the switch appears 8.2 First -Time Start -Up Procedure A WARNING Vent pipes and heater tops get hot! These surfaces can cause serious burns. Do not touch these surfaces while the heater is in operation. Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and replace any part of the control system and any gas control which has been under water. Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the heater. Do not attempt repairs on the gas controls or appliance. Tampering is dangerous and voids all warranties • Choose JANDY REMOTE. WARNING If you do not follow the instructions below exactly, a fire or explosion may result, causing property damage, personal injury or loss of life. • BEFORE OPERATING, smell all around the appliance for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. broken or will not move, don't try to repair it, call a qualified service technician. Force or attempted repair may result in fire or explosion. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system which has been under water. • Confirm that pool water is flowing normally through the pool system and equipment. • If it is a new pool or spa installation, operate the filter pump with the heater off long enough to completely clean the water. This will remove any installation residue from the water. • Clean the filter before starting the heater. • Start the heater in either Pool or Spa mode. See Figure 17. • Start the heater. See Figure 17. • When the heater starts, confirm there is adequate water flow. See Section 5 for details. Page 30 - Jandy® Pro Series, JXi" Gas -Fired Pool & Spa Heater I Installation & Operation Manual 8.2.1 OPERATING INSTRUCTIONS Refer to the Lighting and Shutdown Instructions. See Figure 17 located inside the top panel. • STOP! Read IMPORTANT SAFETY INFORMATION in previous section. • Set temperature thermostat controls to their lowest setting and turn off the controller. Make sure the display shows GAS HEATER IS OFF. Turn off all electrical power to the heater at the junction box. Gas Valve Control Switch oti This appliance is equipped with an ignition device which automatically lights the heater. Do NOT try to light the burner by k... hand. Remove the heater rear ff or top panel. • Toggle gas control switch to OFF position. See Figure 16. Gas Valve Figure 16. 8.2.2 If Ignition Is Unsuccessful If ignition is unsuccessful, or the flame fails during normal operation, the ignition control shuts off the gas valve. The heater will then go through a post purge process and attempt to establish stable combustion two additional times. If ignition is unsuccessful after three 8.3 To Turn Off Gas To The Heater Set temperature thermostat controls to their lowest setting and turn off the controller. Make sure the display shows GAS HEATER IS OFF. Turn off all electrical power to the heater at the junction box. 8.4 Normal Operation During normal operation, the control system measures the temperature of the water flowing through the heater and will begin the start-up process if the temperature is below the set point. If the blower pressure switch senses adequate airflow when the blower starts, the ignition • Wait five (5) minutes to clear out any gas, then smell for gas, including near the floor. IF YOU SMELL GAS, STOP! Follow instructions in Section 8.1.1. • If no gas is detected, toggle gas control switch to ON position. • Replace the rear panel or top. • Turn on electrical power to the heater. • Turn the controller ON by pressing POOL or SPA and set the temperatures as necessary. • NOTE: If the heater does not start, check that the filter pump is ON, the filter is clean and that water is flowing to the pool. If the heater still does not operate, follow the procedure in Section 8.3 to turn off gas supply to the heater. A WARNING When the heater is fired for the first time, the combustion chamber refractory binder material is driven out by the heat of the flame. White smoke and/or sharp odors may be emitted from the vent dur- ing this period. Do not inhale combustion product fumes at any time, and especially when these fumes are being emitted. This "burn -in" period will last only a few minutes. attempts, the system shuts down and will automatically attempt to restart after one hour. • To reset the heater to provide three (3) attempts to start: • Turn OFF the control then turn it back ON. • Access either the Pool or Spa mode. • Remove the rear panel or top. • Toggle gas control switch to OFF. • Shut off the external gas supply valve to the heater. • Replace the rear panel or top. sequence begins. Following a pre purge, the igniter is energized, then the gas valve opens. As long as a flame is sensed at the burner, operation continues until the temperature of the water entering the heater reaches the temperature control setting. Jandy® Pro Series, JXi'" Gas -Fired Pool & Spa Heater Installation & Operation Manual 0 Page 31 ❑ WARNING If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury, or death. (A) This appliance does not have a pilot light. It is equipped with an ignition device which automatically lights the heater. Do NOT try to light the burners by hand. (B) BEFORE OPERATING, smell all around the appliance for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electric switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the Fire Department. (C) Use only your hand to activate the gas control switch. Never use tools. If the switch will not move by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in fire or explosion. (D) Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system which has been under water. 1. STOP Read the safety information above on 9• Replace the top panel. this label. 10. Turn on all electric power to appliance. 2" Set the thermostat to lowest setting and turn 11.* Set thermostat to desired setting and switch appliance switch to OFF. appliance from OFF to either POOL or 3. Turn off all electric power to the appliance. SPA. 4. This appliance is equipped with an ignition 12. If the appliance will not operate, check that device which automatically lights the heater. the filter pump is on, the filter is clean and Do not try to light the burners by hand. water is flowing to the pool. Otherwise, 5. Remove the top panel. follow the instructions "To Turn Gas Off' and call your service technician 6. Tum gas control switch to OFF position or gas supplier. 7. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOPI Follow "B" in the safety information above on this label. If you don't smell gas, go to next step. 8. Turn gas control switch to ON position. MSWIT'�,GAS CONTRO ■��o ;ij of of _ r::' O , o CH IN'OFF* POSTI TO TURN GAS OFF (1) Remove top panel. (2) * Set the thermostat to lowest setting and switch appliance to OFF. (3) Turn off all electrical power to the appliance if service is to be performed. (4) Turn gas control switch to OFF positition. (5) Replace top panel. * See manual for details of operation and thermostat control. POUR VDT AVERTISSEMENT Si vous ne suivez pas ce directives a la lettre, un incendie ou explosion pout an etre le resultat. Ceci causera des dommages aux biens des blessures personnelles ou la Mort. (A) Cot appareil nest pas muni d'une veilleuse. II est muni d'un appareil d'allumage qui dAclenche le chauffe-eau automatiquement. Ne pas esssayer d'aliumer les brlileurs a la main. (B) AVANT DE METTRE EN MARCHE, assurez-vous qu'il n'y a aucune odeur de gaz autcur de I'appareil. Assurez-vous qu'il n'y a aucune odeur de gaz pros du plancher, car certains gaz cont plus lourds qua fair at on pour effet de s'accumuler au plancher. QUOI FAIRE S'IL Y A UNE ODEUR DE GAZ Ne pas essayer de maitre en Marche quelque appareil qua ce Solt. Ne touchez A aucun internupteur electrique. Ne pas faire usage d'un appareil t6l6phonique dan votre Edifice. Contactez immediatement a partir du telephone d'un voisin votre foumisseur de gaz. Suivez ses directives Si vous ne pouvez pas joindre avec votre foumisseur de gaz, appelez le service des incendies. (C) Utilisez seulement votre main pour opArer le bouton de la commande de gaz. Ne jamais utiliser un outil. S'il est impossible d'opArer le bouton a la main, n'essayez pas de le reparer. Appelez un technician de service qualifie. Uutilisation d'une force quelconque peut avoir pour r6sultat un feu ou une explosion. (D) Ne pas utiliser cat appareil si une pioce quelconque a ate submerge. Contactez immediatement un technician qualifi6 afin de faire examiner I'appareil et faire remplacer toute piece du systeme de contr6le ainsi qua toute commande de gaz qui aurait dt6 submerges. DUE ffERIMMIRNM PLS UALIMENTATION ARRETEZ I Lisezhes directives de sdcurrd ci-dessus sureetta 11' R69bzlethermostateommed6sir6ettaumezieboutonds gbquette, commande de la position OFF Alaposition POOL ou Rdglazlethermostatau plus bas etmettezlaeommandede SPA . rappareilblaposition OFF . 1L SII'appareilnosemet pas anmarche,assurezarousquo [a Itteigneztoufealimentation dlectriquedorappareg. pompe du film tonctionne,quo leMrs soitpropreatqu'il ya Cot appareil est muni d'undisposiifd'alluma9equi met le unddbltd'eauvers, lapiscine. Autrementsuivaz[as dfrec- chaufr�auenmarcheautomabquemerRNepasessayer tives. d'allumerlas brftleurs d la main. S Enlevazle panneau supdrieure. 6. Toumez I'interrupteur de commande de gaz jusqu'd la position ON. 7. Attendezpendantcingl5)minutesafinquo kgazsedissipe. Asmreavous qu'd n'yaaucune odeurde gaz, memeau niveau du planchecS'dya une odeurde gazARRtM VOUS I Suivez I'dtape o Be ci-dessus.S'd n'y a pas d'odeurdegaz, procddez'e loprochainedtape. 8. Toumezlel'bnenuptemdecommande dogazjusqu'alaposition OFF. 9. Replacezlepanneausupdrieure. 10. Mettezrappareilsoustension. MGAzACOMMANDE DE O LA I POSITION'OFF' I I Figure 17. Lighting and Shutdown Instructions Label on Top Panel EN GAZ (1) Enlevez le panneau supArieure. (2) . RAglez le thermostat au plus bas et mettre le bouton de commande a OFF. (3) Interrompez toute alimenta- tion electrique a I'appareil si on doit faire de 1'entretien ou rAparation. (4) Tournez I'fnteirupteur de commande de gazjusqu'A la position OFF. (5) Remplacez le panneau superieure. • Voir le manual our lea d4tails eoncernant Pop�mdon du eontrele de 1­10415400_REVD Page 32 q=V Jandy® Pro Series, A- Gas -Fired Pool & Spa Heater Installation & Operation Manual 8.5 Operating the Controller Unless the heater is connected to a remote controller, all operations are set up and programmed through the control panel on the top of the heater. See Figure 18. NOTE: The display light reverts to OFF after two minutes of inactiv- ity since the last key was pressed. 8.5.1 Setting up Heater Options Before using the heater for the first time, set up the following options: • Languages: Set a display language • Temperature Scale: Set temperatures to be displayed in either Celsius or Fahrenheit scale • Display Light Timeout: Set the display light to turn off after a specific interval of inactivity • To Program the Display Language Heater must be in OFF mode to begin. 74*.61 r Hold for 5 Seconds. i� � SELECT USER n SETUP LANGUAGE SELECT LANGUAGE ENGLISH RA ;�Ajjl. or To Change Language Bim. MENU To Save POOL or SPA To Exit ;7pl�nP2A A y 00 POOL MENU Figure 18. Main Control Panel • To Program the Temperature Scale (F or Q Heater must be in OFF mode to begin. (P Hold for 5 Seconds. RA SELECT USER y n � SETUP TEMPERATURE SCA > MENU SELECT TEMP SCALE F A ��� nor to Toggle OF and °C RMENU To Save POOL or SPA To Exit • To Program Display Light to Turn OffAutomatically Heater must be in OFF mode to begin. MENU Hold for 5 Seconds. Aor SELECT USER �j SETUP DISPLAY LIGHT > MENU SELECT DISPLAY LIGHT 2 MIN TIMEOUT ----- RA Dor to Toggle: MENU To Save POOL or SPA To Exit Jandy® Pro Series, JXi'" Gas -Fired Pool & Spa Heater Installation & Operation Manual Page 33 8.5.2 Operating the Heater • To Turn on Pool or Spa Heat T orF(__:T-__80-F— — — --- -- current temp displayed RDor To Change Temperature After 5 seconds of inactivity, new 7Iw Fir-)Set Point temp Is stored as the set point. • To Maintain Pool or Spa Heat (optional Relay and Wiring Required) Toor SPA SET: 80°F current temp displayed 7?610.T9 7A* MAINTAIN POOL HEAT Or MAINTAIN SPA HEAT SET: 80°F current temp displayed �� A To Change Temperature After 5 seconds of Inactivity, new Set Point temp is stored as the set point. d 8.6 Shutting Down the Heater Complete shutdown instructions are as follows. Refer to Figure 17. • Set temperature thermostat controls to their lowest setting and turn off the controller. Make sure the display shows OFF. • Turn off all electrical power to the heater at the junction box. If connected, the Maintain Heat mode monitors the pool water temperature 24 hours a day by turning the pool pump on and sampling the water temperature. When the water temperature drops below the programmed temperature set point, the controller automatically starts heating the pool. • To Turn the Heater Off !�POOL Press once to enter Pool Heat Mode. Press again to turn Pool Heat Mode Off Press once to enter Spa Heat Mode. Press again to turn SPA Spa Heat Mode Off When the control panel is OFF, the screen displays: GAS HEATER IS OFF PRESS POOL OR SPA. • Temperature Set Point Lock Once you have programmed pool temperature and spa temperature set points, you can lock them so that they may not be changed inadvertently. or SPA 5ET:80°F - - current temp displayed Press both Keys at SET POINT LOCKED same time. S Ivy Hold for 7 seconds ET POINT UNLOCKED ISz� Lock or unlock depending on current setting. • Remove the top panel of the heater. • Turn the gas valve control switch to OFF. • Shut off the external gas supply valve to the heater. • Replace the top panel. Page 34 Jandv* Pro Series, JXi' Gas -Fired Pool & Spa Heater Installation & Operation Manual Section 9. Maintenance If the heater is not going to be used for an extended period of time and in colder climates, shut it down completely. See Section 8.6 and Figure 17. IMPORTANT MAINTENANCE NOTE We recommend that before each pool season, the Thermal Regulator Valve (TRV) be inspected for proper operation and replaced if there are signs of scaling or corrosion. Corrosion and scaling are the result of improperly 9.1 Water Chemistry Proper Water Balance is the key to the enjoyment of your pool or spa experience and to the long life of your heater. The pH of your pool or spa's water is one of the factors that has the most impact on indicating how properly balanced the water is. The other factors are: temperature, total alkalinity, calcium hardness and total dissolved solids. Cold water is typically more acidic (corrosive), while hot water tends to lead to a scale forming (basic) condition. While the heater is in operation, if the PH is allowed to rise above 7.8 and the calcium hardness and 9.1.1 Saturation Index PH, Total Alkalinity (TA), temperature, Calcium Hardness and Total Dissolved Solids (TDS) play a role in whether the water is either corrosive or scale forming. These factors are combined in the Langelier Saturation Index, which is a method for determining whether or not water is properly balanced. See Table 6 below. Saturation Index = pH + AF + CF + TF -12.1* A-Factor=(AF), C-Factor=(CF), T Factor -(TF) Total Alkalinity Calcium Hardness Temperature A -Factor C -Factor T Factor PPM Factor Value PPM Factor I Value aF Factor Value 5 = 0.7 5 = 0.9 32 = 0.0 25 = 1.4 25 = 1.0 37 = 0.1 50 = 1.7 50 = 1.3 46 = 0.2 75 = 1.9 75 = 1.5 53 = 0.3 100 = 2.0 100 = 1.6 60 = 0.4 150 = 2.2 150 = 1.8 66 = 0.5 200 = 2.3 200 = 1.9 76 = 0.6 300 = 2.5 300 = 2.1 84 = 0.7 400 = 2.6 400 = 2.2 94 = 0.8 800 = 2.9 800 = 2.5 105 = 0.9 A saturation index of 0 is perfectly balanced A negative saturation index has corrosive tendencies A positive saturation index has scaling tendencies A saturation index of +0.3 or -0.3 is ideal *-12.1 should be changed to -12.2 if Total Dissolved Solids (TDS) measure at 1,000 ppm or greater Table 6. Water Saturation Index balanced water please see Section 9. LI for complete details on managing your water chemistry. The TRV ensures the heater operates at it's optimal efficiency and if properly maintained will extend the life of the heater. A WARNING Do not operate the heater if the water temperature is below 40 'F (4°C) total alkalinity are not properly maintained; calcium in the water could lose solubility, coating the copper tubes inside the heat exchanger. This will restrict the flow of water resulting in reduced efficiency and possible damage to the heater. If the pH is allowed to drop below 7.2, and the alkalinity is not properly maintained, the water will become more acidic. Acidic water has a tendency to dissolve metal components in the pool plumbing such as copper tubing in the heat exchanger. The practice of putting tablet -based sanitizer in the skimmer basket can produce heavily chlorinated water with very low pH. If this comes in contact with metal parts of the heater it can cause serious damage. Practices like this should be discontinued. If acidic conditions are present, there could be signs of metal in the pool water that could cause staining on the floor of your pool. This might manifest itself in the form of brown stains on the finish of your pool bottom or pool water discoloration. Your local pool dealer can test for metals in your water or can provide you with a test kit. Every effort should be made to maintain the water balance of your pool or spa in the proper range. Ignoring this very important component of your pool's water chemistry can make the water less enjoyable to bathe in and result in permanent damage to your heater and/or complete failure of individual components. Zodiac Pool Systems does not warrant heat exchangers damaged by corrosive water issues or from the build-up of calcium in the heater's heat exchanger. Any questions regarding proper water balance can be directed to our product support line at Zodiac® or to your local pool dealer. NOTE: The Thermal Regulator Valve (TRV) is an indicator of how well the water balance is being maintained. The TRV should be in- spected before each pool season to ensure it is clean and operating properly. If you see signs of calcium buildup (scale -forming or base water) or corrosion (acidic water) the TRV should be replaced and your water balanced. Jandy® Pro Series, JXi'" Gas -Fired Pool & Spa Heater Installation & Operation Manual Page 35 9.2 Swimming Pool Energy Saving Tips Please review the following recommendations to help conserve fuel and minimize the cost of operating your pool heater without sacrificing comfort. • The American Red Cross® recommends a maximum water temperature of 78°F (26°C). Use an accurate pool thermometer. A difference of 4°F (2°C), between 78°F and 82°F (26°C and 28°C), will use as much as 40% more gas. • Carefully monitor the water temperature of your pool in the summertime. You can reduce heater usage due to warmer air temperatures. • Find the proper setting on the pool heater temperature control and use the Set Point Lockout feature to discourage further adjustments. • Set the pump time clock to start the pump no earlier than 6:00 AM. This is the time when nightly heat loss balances. 9.3 Winterizing In areas where freezing temperatures occur in winter and the pool or spa will not be used, the pool should be winterized by a qualified pool service technician: • Turn off the electrical supply and the main gas supply to the heater. • Remove the heater access panel. • Turn off gas supply to the heater following the shut- down instructions. See Section 8.6 and Figure 17. • Remove the drain plug from the inlet/outlet header and completely drain the heater before the first frost. See Section 5.5.1 step "a" • Inspect the gasket on the drain plug. Store the drain plug in a safe place for winter. • Cover the exhaust vent grill with plastic so that snow will not accumulate and freeze on top of the combustion chamber. 9.4 Spring Start-up When winterized, the heater should be reassembled by a qualified professional technician in the Spring. • Reinstall the drain plug. • Uncover the vent grill. • Reattach copper tubing to water pressure switch. • Make sure power is supplied to the pump. • If the pool is only going to be used on weekends, reduce the heater temperature control setting by 8 or 10 degrees during the week. Reset it to the 78°F (26°C) level a day or so before you plan to use the pool. • During the winter or when on vacation for longer than a week, shut down the heater by following the shutdown instructions found in Section 8.6 and Figure 17. and on the inside of the heater. • Where possible, shelter the pool from prevailing winds with well -trimmed hedges or other landscaping, cabanas, or fencing. • The greatest source of heat loss in a swimming pool is through evaporation. It can account for 50% of pool systems total heat loss. The use of solar blankets, automatic covers or anything that limits the air's access to the surface of the water will help reduce this heat loss and minimize evaporation. • Remove and drain the copper tubing (siphon loop) for the water pressure switch. PRESSURE SWITCH COPPER TUBING DISCONNECT HERE (WINTERIZING) Figure 19. Water Pressure Switch Copper Tubing (Siphon Loop) • Turn on the filter pump and circulate water through the heater for 5 minutes. Check for leaks while circulating. • Turn on the main gas supply to the heater at the gas cock outside the heater jacket. • Turn on the heater according to Section 8.6 and Figure 17. Page 36 N111= Jandy® Pro Series, JXi" Gas -Fired Pool & Spa Heater I Installation & Operation Manual 9.5 Inspection and Service A WARNING Improper installation or maintenance can cause nausea or asphyxia- tion from carbon monoxide in flue gases which could result in severe injury, or death. The heater is designed and constructed to provide long performance life when installed and operated properly under normal conditions. Periodic inspections, especially at spring start-up, are important to keep your heater running safely and efficiently through the years. Zodiac Pool Systems, Inc. recommends that the homeowner 9.5.1 Guidelines for Homeowner Inspection: A WARNING Do not store or use gasoline or other flammable vapors, liquids or chemicals in the vicinity of this or any other appliance. A WARNING Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and replace any part of the control system and any gas control which has been under water. 9.5.2 Guidelines for Professional Inspection: The following inspections should be made once a year or as needed. Routine inspections are a critical to the safety and long life of your Jandy pool equipment. • Check for loose or broken wires and terminal connections. • Check the water pressure switch by turning the filter pump off and on several times. The burner should go off immediately after the pump stops. The fan will run for 45 seconds after the burner shuts down. CAUTION If the heater is wired serially to or on the same relay as the filter pump, there is a chance that power will be disconnected to the heater before the fan is able to fully purge the combustion chamber. It is inadvisable to install the heater in a manner which would pre- vent this combustion chamber purge from taking place. An ignition sequence should start shortly after the pump is turned back on. Inspection the thermal regulator valve (TRV). Inspect the electrical controls, specifically: a. High limit switches b. Water pressure switch c. Automatic gas valve d. Power interface/Temperature control e. Flue temperature sensor f. Control circuit fuse g. Ignition control h. Air pressure switch inspect the heater on a regular basis (especially after abnormal weather conditions), and arrange to have a professional inspection at least once a year by a qualified service technician. A WARNING For your safety, when starting the heater, keep your head and face away from the exhaust grill opening and blower inlet grill to prevent any risk of personal injury. Make sure all doors/panels are securely in place and stand back from the heater. • Keep the top of the heater, under the heater, and surrounding area clear of all debris and combustible materials such as paper, leaves, etc. • If there is a pressure relief valve, check for corrosion in and around the valve. If there is corrosion, turn off the filter pump and replace the pressure relief valve. • Once a year check that water is running freely through the pressure relief valve. To check, turn on the filter pump and lift the release lever on the top of the valve. • Be sure combustion air and ventilation openings are not blocked. • Inspect the inlet grill at the blower for blockage, leakage, and corrosion. • Inspect the combustion blower for damage. • Conduct a normal operating cycle and observe that the sequence proceeds as intended. • If the heater is equipped with a pressure relief valve, clean any accumulated corrosion and make sure that water runs freely when lever is lifted. • Inspect combustion chamber and blower exterior for corrosion and indication of improper operation. • Inspect electrical controls for deterioration. Repair and replace as necessary. • Visually check the main burner flame. Remove the top of the heater to inspect the sight glass. See Figure 20 Figure 20. Remove Heater Top to View Sight Glass Jandy® Pro Series, JXi- Gas -Fired Pool & Spa Heater Installation & Operation Manual Page 37 Section 10. Troubleshooting 10.1 Common Problems Zodiac Pool Systems, Inc. strongly recommends that you call a qualified service technician to perform all service and repairs on the heater. To locate a licensed or qualified technician service company, call Jandy Technical Support at 800.822.7933, or visit www jandy.com, The following table lists some of the most common problems when running the heater. Most problems occur when the heater is started for the first time after installation or at spring start-up. SymptomPossible Pump not operating No power. Check circuit breakers and power source. Pump defective. Replace the pump. Incorrectly wired. Recheck wiring. Time clock settings not synchronized Check time clock setting. with actual time. Unstable combustion- Wrong gas. Make sure the gas supply matches the gas type (1) heater turns off and on Lean fuel/air mixture— low supply indicated on the rating plate. (2) heater ignites slowly pressure. Correct gas supply inlet pressure to: (3) flame lifts and goes out Lean fuel/air mixture— too much (NATURAL GAS) 4.0 " W.C. min - 10.5' W.C. max (4) short yellow streaked flame combustion air. (PROPANE) 4.0 " W.C. min - 14.0" W.C. max Rich fuel/air mixture— high manifold Offset pressure should be -0.2" W.C. Use a digital pressure. differential manometer to verify correct offset pressure. Rich fuel/air mixture— too little Adjust offset pressure as needed. See Section 4.3 combustion air. Connect a digital differential manometer to blower throat and gas valve port to obtain differential. Make sure the differential value falls within the specified range for the heater size. See Section 4.3 Gas meter too small. Gas line from meter to heater too small. Check blower inlet grill for obstruction. Not enough heat Heater size inadequate. Replace with heater of higher output. (1) heater is slow to heat up Filter pump not running long enough. Replace TRV. (2) heater not maintaining set Thermal regulator valve (TRV) is Heater is condensing. Flue product moisture will temperature opening early or is permanently open. condense at the start-up until the heater water (3) Low temperature rise Heater plumbed backwards. temperature reaches the normal operating conditions. Correct the plumbing. Heater pounding or knocking Water flow through heater too low. Look for obstruction or closed valve in system. Failed Thermal Regulating Valve (TRV). Check for damaged internal bypass. Variable speed pump set too low Dirty filter or baskets Igniter lights but heater does Gas valve is not ON. Flip the switch to "on" position. not fire Air in gas line. Cycle ignition sequence until air is out of the gas line. No power to gas valve. Check controls for proper operation. Low gas pressure/volume. Check supply pressure/volume and verify proper gas supply pipe size. High burner throat pressure. Replace gas valve. Gas valve failed. NOTE: Gas valve failures are extremely rare. Please confirm this as the root problem before replacing. Page '. Jandy` Pro Series, JXi- Gas -Fired Pool & Spa Heater Installation & Operation Manual 10.2 Service Diagnostic Messages The controller monitors several functions of the heater. Service Messages along with potential causes and In the event of a malfunction, the controller will display remedies. a FAULT message. The following table lists the Heater MessageFault Possible The LED light is on CHECK FLOW Pump is not running. Check breakers and power source, recheck wiring, set LED single flash. Low pump pressure. time clock and current time. Flame exists when there is Pressure switch fault. Clean filter or clear blockage, check position of valve in Variable speed pump set too low. plumbing system. Ignition lockout (heater has Make sure return eyeball fittings are installed on the attempts to fire and is in a soft wall of the pool lockout condition). Adjust or replace pressure switch. Adjust variable speed pump. Refer to qualified service personnel. FAULT- Water temperature in heater exceeds Inspect vent for obstructions or blockages. HIGH LIMIT the internal limit. Indoor installations, check vent pipe for bird, insect or Limit switch fault. rodent activity that could cause a blockage. Replace switches. Refer to qualified service personnel. FAULT - HIGH FLUE Flue temp limit fault Identify and correct loose connections. TEMPERATURE Replace flue sensor. Refer to qualified service personnel. FAULT- Broken, split, pinched or disconnected Check tubing and replace if necessary. CHECK IGN CONTROL air pressure switch tubing. Correct fault or replace fan. Fan not operating. Replace igniter. Fan running slow or premature fan Verify proper wiring for 120 VAC or 240 VAC. failure. Check for proper clearances around heater and for Air flow restricted at intake or discharge. adequate room ventilation if enclosed. Inspect for Broken igniter. blockage or restriction at discharge of flue. Low gas supply pressure/volume. Check ignition control LED codes (see Section 10.3, No flame at burner. Ignition Control LED Service Codes). Verify that the size, length and number of elbows on the gas supply line meet national codes. Identify and correct loose wiring connections, or problems with igniter, gas valve, or ignition control. Refer to qualified service personnel. FAULT- Faulty wiring or connection. Inspect water temperature sensor wiring. SHORTED H2O SENSOR Failed water temperature sensor. Ensure sensor is connected correctly into the power or interface board (PIB). FAULT- Replace water temperature sensor. OPEN WATER SENSOR Refer to qualified service personnel. FAULT- Status message indicating the filter No Service Required. This is normal when the control PUMP pump is currently turned OFF when the is in a Maintain Temp mode. heater system programmed in Maintain Temp mode. 10.3 Ignition Control LED Service Codes In addition to service diagnostic messages, the ignition controller has an LED light that flashes to indicate various ignition control faults. The table below lists the LED codes and the corresponding fault description. To diagnose possible cause and remedy, refer to Section 10.2, Service Diagnostic Messages. LED Code Fault Description The LED light is on Ignition Control Fault. Refer to continuously. qualified service personnel. LED single flash. Air flow fault. LED double flash. Flame exists when there is NO call for heat. Refer to qualified service personnel. LED triple flash. Ignition lockout (heater has made three (3) unsuccessful attempts to fire and is in a soft lockout condition). Jandr Pro Series, JXi" Gas -Fired Pool & Spa Heater Installation & Operation Manual Page 39 Section 11.Professional Service and Maintenance Call a qualified service technician to perform all service and repairs on the heater. To locate a licensed or qualified technician or independent service company in your area, contact Zodiac Technical Support at: 1-800-822-7933 www.jandy.com Before servicing the heater: • Confirm that the heater control is set to either POOL or SPA • Confirm the temperature set point for either Pool or Spa is set high enough to make the heater operate given the current water temperature. Section 12. Spare Parts Using genuine Zodiac factory replacement parts helps to ensure the ongoing quality and reliability of our products. Unauthentic parts might seem okay on the surface, but they often fall short of factory standards, and they typically lack the backing you get from an established, global manufacturer like Zodiac. Plus, the use of unauthentic parts voids all factory warranties. Zodiac does not sell parts directly to pool owners, so 12.1 Major Components Heat System �- See Section 11.4 A WARNING SERVICING SAFETY Service procedures can be hazardous because they involve fuel gas, electricity, moving parts and procedures which require testing or temporary bypass of safety controls. For this reason, the heater must be serviced only by a qualified professional service technician. IMPROPER SERVICE HAZARD The heater incorporates unique design features. Incorrect service of this heater can result in personal injury or damage to property. To avoid such hazards, the heater must be serviced only by a qualified professional service technician. when it's time for maintenance, please see your local Preferred Professional Provider (PPP) of genuine parts. You can find a PPP at www.zodiacpoolsystems.com/ parts. NOTE: To identify the correct part, you will need to know the model number, serial number and type of gas when applicable. This information can be found on the rating plate sticker, which is located inside the heater on the outside of the combustion chamber. See Section 11.3 Water System* See Section 11.5 Electrical System See Section 11.6 Page 40 Jandy® Pro Series, JXi'" Gas Fired Pool &Spa Heater Installation &Operation Manual 12.2 Cabinet Assembly Spare Parts List and Exploded Parts Diagram Key No 1 Description Heater Jacket Top Kit (no User Interface) model 200 R0592400 model 260 R0592400 model 400 R0592400 2 Corner Post Kit, Left/Right (set of 2) R0592500 R0592500 R0592500 3 Heater Base Kit R0592600 R0592600 R0592600 4 Front or Back Panel Kit R0592700 R0592700 R0592700 5 Side Panel Kit* R0592900 R0592900 R0592900 6 Vent Terminal Housing Kit R0593100 R0593100 R0593100 7 Jacket Hardware Kit (speed nuts, screws, jacket clips) R0593300 R0593300 R0593300 8 Anchor Brackets Kit (set of 4) R0593400 R0593400 R0593400 9 Jacket Hole Plug Kit R0591800 R0591800 R0591800 10— Complete Replacement Box Packaging Kit R0593600 R0593600 R0593600 "`Includes: Exhaust side panel, top panel closure, anti rotation bracket and access door. Header side panel LH, Header side panel RH. ** Not Shown 9 p Jandy' Pro Series, JXi- Gas -Fired Pool & Spa Heater I Installation & Operation ManualMEW Page 41 12.3 Heat System Spare Parts List and Exploded Parts Diagrams 12.3.1 Combustion Chamber Assembly Key No Description model 200 model 260 model 400 1 Exhaust Elbow Assembly Kit R0590200 R0590200 R0590200 2 3 Band Clamp Kit Refractory Kit, Internal Combustion Chamber Shelf (set of 2: Models 200, 260) Combustion Chamber Lid Kit Gasket Kit R0590400 R0590500 R0590700 R0590800 R0590400 R0590400 R0590500 R0590500 R0590700 R0590800 4 R0590700 5 R0590800 6 R0590900 R0590900 R0590900 7 Sight Glass Kit R0305400 R0305400 R0457502 R0305400 8 9 Ignitor Kit R0457502 R0457502 Insulation Kit, External R0591000 R0591000 R0591000 10 Isolator Kit (Thermal) R0593200 R0593200 R0593200 11 Heat Exchange Assembly R0589402 R0589403 R0589405 8 7 Page 42 Jandy® Pro Series, JXi" Gas -Fired Pool & Spa Heater I Installation & Operation Manual 12.3.2 Burner Assembly 1 Description model 200 "LIP Blower Assembly Kit R0591100 R0591100 model 260 N LIP R0591100 R0591100 model 400 N LP R0591100 R0591100 2 Air Intake Grate Kit R0591200 R0591200 R0591200 R0591200 R0591200 R0591200 3 Blower Intake Orifice Kit R0591302 R0591312 R0591303 R0591313 R0591305 R0591315 4 Fuel Orifice Kit R0591601 R0591605 R0591602 R0591606 R0591604 R0591608 5 Gas Valve R0591400 R0591400 R0591400 R0591400 R0591400 R0591400 6 Burner Kit R0591702 R0591702 R0591703 R0591703 R0591705 R0591705 7 Capacitor Kit R0614500 R0614500 R0614500 R0614500 R0614500 R0614500 * N - Natural Gas **LP - Liquid Propane Jandy® Pro Series, JXi" Gas -Fired Pool & Spa Heater I Installation & Operation Manual 12.4 Water System Spare Parts List and Exploded Parts Diagrams Key No 1 AW Description Access Door Kit (with O -Ring Seal and Screws) model 200 model 260 model 400 R0589600 R0589600 R0589600 2 Thermal Regulator Valve Kit (TRV) R0589700 R0589700 R0589700 3 Bypass Kit R0589800 R0589800 R0589800 4 Drain Plug Kit R0446000 R0446000 R0446000 5 Gasket and Seals Kit R0589500 R0589500 R0589500 6 Manifold Backplate Kit R0590002 R0590003 R0590005 7 Manifold, 3 Port (no backplate included; must order separately) R0590100 R0590100 R0590100 8 Water Pressure Switch Kit R0457001 R0457001 R0457001 9 Goody Bag Kitt R0593500 R0593500 R0593500 10 Universal Half Union Kit (1 Ea, requires 2 kits for full unit replacement) R0522900 R0522900 R0522900 11 Sweep Elbow Aqualink®Temp Sensor SEAQL1001 SEAQL1001 SEAQL1001 12 Drain Cap Assembly Kit R0523000 R0523000 R0523000 13 Pressure Relief Valve (PRV) Install Kit R0336101 R0336101 R0336101 Page 4S t Goody Bag Kit Also Includes the Installation and Operation Manual and the Universal Controller Quick Guide d 00op DA 8 .4 so Page 44 N= Jandy® Pro Series, JXi- Gas -Fired Pool & Spa Heater I Installation & Operation Manual 12.5 Electrical System Spare Parts List and Exploded Parts Diagrams Key No* 1 Description Ignition Control Kit model 200 R0456900 model 260 R0456900 model 400 R0456900 2 Transformer Kit R0456300 R0456300 R0456300 3 User Interface Kit R0591900 R0591900 R0591900 4 User Interface Lid Kit R0592000 R0592000 R0592000 5 Wiring Harness Kit R0592100 R0592100 R0592100 6 Air Pressure Switch Kit R0456400 R0456400 R0456400 7 Flue Temp Sensor§ R0719400 R0719400 R0719400 7a Fusible Linkt R0524300 R0524300 R0524300 8 Water Pressure Switch Kit R0013200 R0013200 R0013200 Power Interface Board (PIB)§ R0719500 R0719500 R0719500 9 Power Interface Board (PIB)$ R0458200 R0458200 R0458200 10 Power Distribution Board (PDB) R0458100 R0458100 R0458100 11 Temperature Sensor Kit R0456500 R0456500 R0456500 12 High Limit Temperature Sensors Kit R0592300 R0592300 R0592300 13 Igniter Kit R0457502 R0457502 R0457502 14 Power Interface Harness R0457700 R0457700 R0457700 t Fusible Link to replace factory installed fusible link on heaters with serial number revision G or earlier. $ PIB to replace factory installed PIB on heaters with serial number revision G or earlier. Upgraded components R0719400 and R0719500 must both be installed for heater to operate properly. § Flue Temp Sensor and PIB must be replaced together in Rev G and earlier heaters. Both parts are required order to install the VersaFloTm Bypass accessory PN: JXIVFKIT. 10 11 Items not shown in illustration: • Power interface, controller harness w/bypass • Universal controller main reset, rollout switch harness • User interface, universal controller harness 4' O Jandy® Pro Series, A- Gas -Fired Pool & Spa Heater I Installation & Operation Manual Page 45 NOTES Page 46 Nm Jandy® Pro Series, A- Gas -Fired Pool & Spa Heater ' Installation & Operation Manual NOTES Jandy® Pro Series, JXi- Gas -Fired Pool & Spa Heater Installation & Operation Manual r Page 47 NOTES (so Zodiac Pool Systems, Inc. 2620 Commerce Way, Vista, CA 92081 1.800.822.7933 1 www jandy.com ZODIAC® is a registered trademark of Zodiac International, S.A. S. U., used under license. All other trademarks referenced herein are the property of their respective owners. ©2016 Zodiac Pool Systems, Inc. H0404700 REVG