Loading...
450 GARDEN LN SOLR23-0003 COAB Permit Form with ConditionsFinal Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION SOLAR PANEL SYSTEM SOLR23-0003 & ERES23-0157 450 GARDEN LN SOLAR ENERGY LABS INC OWNER:ADDRESS:CITY:STATE:ZIP: LYNAGH MINHTHU NGO TRUST ET AL 450 GARDEN LN ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: SOLAR ENERGY LABS INC 1057 ELLIS ROAD N #17 JACKSONVILLE FL 32254 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 172020 5216 SELVA MARINA GARDEN 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 450 GARDEN LN ELECTRICAL SOLAR PANEL Adding 7.3kw Solar PV System $23652.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT ELECTRICAL BASE FEE 455-0000-322-1000 0 $55.00 SOLAR COLLECTOR SYSTEM 455-0000-322-1000 0 $30.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 7/7/2023 PERMIT NUMBER SOLR23-0003 ISSUED: 7/7/2023 EXPIRES: 1/3/2024 ELECTRICAL SOLAR PANEL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 TOTAL: $89.00 2 of 2Issued Date: 7/7/2023 PERMIT NUMBER SOLR23-0003 ISSUED: 7/7/2023 EXPIRES: 1/3/2024 ELECTRICAL SOLAR PANEL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247-5826 Fax (904) 247-5845 Job Address: Permit Number: Legal Description Parcel #___________________________ Floor Area of Sq.Ft. Sq.Ft Valuation of Work $ Proposed Work heated/cooled _______ non-heated/cooled _________ Class of Work (circle one): New Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s) (circle one): Commercial Residential If an existing structure, is a fire sprinkler system installed? (Circle one): Yes No N /A Florida Product Approval # _____________ For multiple products use product approval form Describe in detail the type of work to be performed: Property Owner Information: Name: Address: City State Zip Phone E-Mail or Fax # (Optional) Contractor Information: Company Name: Qualifying Agent: Address: City State Zip Office Phone Job Site/ Contact Number _____________________Fax # _________________ State Certification/Registration # Architect Name & Phone # Engineer’s Name & Phone # Fee Simple Title Holder Name and Address_____________________________________________________________________ Bonding Company Name and Address_________________________________________________________________________ Mortgage Lender Name and Address __________________________________________________________________________ Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six (6) months, or if construction or work is suspended or abandoned for a period of six (6) months at any time after work is commenced. I understand that separate permits must be secured for Electrical Work, Plumbing, Signs, Wells, Pools, Furnaces, Boilers, Heaters, Tanks and Air Conditioners, etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other federal, state, or local law regulating construction or the performance of construction. Signature of Owner Print Name Sworn to and subscribed before me this Day of , 20 Notary Public Signature of Contractor Print Name Sworn to and subscribed before me this Day of , 20 Notary Public Revised 01.26.10 450 GARDEN LN ATLANTIC BEACH, FL 32233 38-39 09-2S-29E SELVA MARINA GARDEN TWO LOT 8 R-172020-5216 23652.00 adding 7.3kW solar pv system LYNAGH MINHTHU NGO TRUST ET A 450 Garden Ln Atlantic Beach FL 32233 Solar Energy Labs Inc Michael D Newman1057 Ellis Rd N # 17 Jax FL 32254904-693-4555 904-693-4555CVC56672 Michael D NewmanMichael D Newman (agent auth attached) 8 June 23 8 June 23 SOLR23-0003 SOLR23-0003 By Toni Gindlesperger at 8:20 am, Jun 29, 2023 JOB COPY SOLR23-0003 By Toni Gindlesperger at 8:38 am, Jun 29, 2023 06/28/2023 RE: Structural Certification for Installation of Residential Solar        MINHTHU LYNAGH:450 GARDEN LN, ATLANTIC BEACH, FL, 32233 Attn: To Whom It May Concern Code 2020 Florida Building Code (ASCE 7‐16) Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 130 mph PV Dead Load DPV 3 psf Exposure B Roof Live Load Lr 20 psf Ground Snow S 0 psf If you have any questions on the above, please do not hesitate to call. Sincerely, Vincent Mwumvaneza, P.E EV Engineering LLC 276‐220‐0064/951‐355‐3348 Exp: 2/28/2025   This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of  the PV system to existing roof framing.  From the field observation report, the roof is made of Composite  shingle roofing over 1/2 inch plywood supported by 2X4 Trusses at 24 inches .The slope of the roof was  approximated to be 23 degrees and having an allowable maximum chord span of  8 feet between supports. After review of the field observation data and based on our structural capacity calculation, the existing roof  framing has been determined to be adequate to support the imposed loads without structural upgrades.  Contractor shall verify that existing framing is consistent with the described above before install. Should they  find any discrepancies, a written approval from SEOR is mandatory before proceeding with install. Capacity  calculations were done in accordance with applicable building codes. projects@evengineersnet.com http://www.evengineersnet.com Vincent Mwumv aneza Digitally signed by Vincent Mwumvaneza Date: 2023.06.28 21:47:29 -04'00' By Toni Gindlesperger at 8:56 am, Jun 29, 2023JOB COPY Structural Letter for PV Installation Date: 06/28/2023 Job Address:450 GARDEN LN ATLANTIC BEACH, FL, 32233 Job Name:MINHTHU LYNAGH Job Number:230628ML Scope of Work Table of Content Sheet 1 Cover 2 Attachment checks 3 Roof Framing Check 4 Seismic Check and Scope of work Engineering Calculations Summary Code 2020 Florida Building Code (ASCE 7‐16) Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 0 psf Wind Load (component and Cladding) V 130 mph Exposure B References NDS for Wood Construction Sincerely, Vincent Mwumvaneza, P.E EV Engineering LLC 276‐220‐0064/951‐355‐3348 Exp: 2/28/2025   This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of  the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per  manufacturer's approved installation specifications.  projects@evengineersnet.com http://www.evengineersnet.com JOB COPY Wind Load Cont. 130 mph ASCE 7‐16 Figure 26.5‐1B B 1.0 ASCE 7‐16 Sec 26.8.2 0.57 ASCE 7‐16 Table 26.10‐1 0.85 ASCE 7‐16 Table 26.6‐1 1.00 ASCE 7‐16 Table 26.9‐1 20.94 psf 23.0 Degrees 1.5 Conservatively assuming all exposed 0.8 conservatively assuming 10 ft2 effective area Uplift (W)Zone(1,2e) Zone(2r, 2n) Zone(3e) Zone(3r) Fig. 30‐3‐2 GCp=‐1.3 ‐1.7 ‐1.7 ‐1.8 Eq. 29.4‐7 P=qh(GCp)(γE)(γa)=‐32.67 ‐42.72 ‐42.72 ‐45.24 GCp=0.6 Figure 30.3‐2 P=qh(GCp)(γE)(γa)=15.08 Equation 29.4‐7 Rafter Attachments: 0.6D+0.6W (CD=1.6)  Connection Check 5/16" Lag Screw Withdrawal value= 266 lbs/in Table 12.2A ‐ NDS 2.5 in DFL Assumed Prying Coefficient 1.4 Allowable Capacity= 760 lbs Zone Average Trib Width Area (ft) Uplift (lbs) Down (lbs) Zone(1,2e)4 10.2 118.2 99.9 Zone(2r, 2n)4 10.2 151.5 99.9 Zone(3e)2 5.1 75.8 99.9 Zone(3r)2 5.1 79.9 99.9 Conservative Max=151.5 < 760 CONNECTION IS OK  KZt = Risk Category =II V= Exposure = 1. Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind uplift  governs  2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw.  Embedment in sheading or other material does not count. KZ = Kd = Ke = qh= 0.00256KzKztKdKeV2= Pitch = γE= γa= Lag Screw Penetration projects@evengineersnet.com http://www.evengineersnet.com JOB COPY Vertical Load Resisting System Design Trusses Max Length, L = 8.0 ft (Beam maximum Allowable Horizontal Span) Tributary Width, WT =24 in Dr =10psf 20 plf Lr =20 psf Wdown=15.08 psf 30.2 plf Pv= 3 psf 6 plf Load Case: DL+0.6W (CD=1.6) Pv max Shear= 99.9 lbs Max Moment, Mu =235 lb‐ft Conservative Max Shear, Vu=wL/2+Pv Point Load =204 lb Note: Proposed loading will add less than 5% of the existing loads. Member Capacity DF‐L No.2  2X4 CL CF Ci Cr KF φλ Fb =900 psi 1.0 1.5 1.0 1.15 2.54 0.85 0.8 1553 psi Fv =180 psi N/A N/A 1.0 N/A 2.88 0.75 0.8 180 psi E = 1600000 psi N/A N/A 1.0 N/A N/A N/A N/A psi Emin =580000 psi N/A N/A 1.0 N/A 1.76 0.85 N/A 580000 psi Depth, d = 3.5 in Width, b = 1.5 in Cross‐Sectonal Area, A = 5.25 in2 Moment of Inertia, Ixx =5.35938 in4 Section Modulus, Sxx =3.0625 in3 Allowable Moment, Mall = Fb'Sxx =396.2 lb‐ft DCR=Mu/Mall =0.37 < 1 Satisfactory Allowable Shear, Vall = 2/3Fv'A =630.0 lb DCR=Vu/Vall =0.32 < 1 Satisfactory Design Value Adjusted Value projects@evengineersnet.com http://www.evengineersnet.com JOB COPY Siesmic Loads Check Roof Dead Load 10 psf  % or Roof with Pv 18.4% Dpv and Racking 3 psf Average Total Dead Load 10.6 psf Increase in Dead Load 2.2%OK  Limits of Scope of Work and Liability The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and  therefore no further seismic analysis is required. We have based our structural capacity determination on information in pictures and a drawing set titled PV plans ‐ MINHTHU LYNAGH. The analysis was according to applicable building codes, professional engineering and design  experience, opinions and judgments. The calculations produced for this structure's assessment are only for the  proposed solar panel installation referenced in the stamped plan set and were made according to generally  recognized structural analysis standards and procedures.  projects@evengineersnet.com http://www.evengineersnet.com JOB COPY Ashley Lopez <ashley.lopez@energylabsinc.com> JEA Interconnection Application For Project JEA-14831 - Lynagh - Is Approved. 1 message JEA DISTRIBUTED GENERATION <DoNotReply@powerclerk.com> Wed, Jun 21, 2023 at 3:34 PM Reply-To: JEA DISTRIBUTED GENERATION <DISTGEN@jea.com> To: ashley.lopez@energylabsinc.com, barbara.newman@energylabsinc.com, mike.newman@energylabsinc.com, paul.getman@energylabsinc.com Cc: lynaghb@gmail.com JEA PROJECT #: JEA-14831 STATUS: Interconnection Application Approved by JEA CUSTOMER NAME: William Lynagh PROJECT ADDRESS: 450 Garden Lane Atlantic Beach, FL 32233 PV PANEL QUANTITY: Inverter: 20 x Enphase Energy 0.4 kW (Model IQ8A-72-2-US (240V) [SI1]) PV Module Array: 20 x REC Solar 365W (Model REC365NP2 Black) BATTERY STORAGE: COMMENTS: NEXT STEP: Contractor Submits Active Electric Permit # From Local Building Department Into PowerClerk. JEA - System Analysis www.jea.com Energy Labs Mail - JEA Interconnection Application For Project JEA-... https://mail.google.com/mail/u/0/?ik=8535cccdf0&view=pt&search=al... 1 of 1 6/28/2023, 9:23 AM By Toni Gindlesperger at 9:13 am, Jun 29, 2023 JOB COPY DESCRIPTION ACCOUNT QTY PAID PermitTRAK $89.00 SOLR23-0003 Address: 450 GARDEN LN APN: 172020 5216 $89.00 ELECTRICAL $55.00 ELECTRICAL BASE FEE 455-0000-322-1000 0 $55.00 MECHANICAL $30.00 SOLAR COLLECTOR SYSTEM 455-0000-322-1000 0 $30.00 STATE SURCHARGES $4.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R23779 $89.00 Printed: Friday, July 7, 2023 2:14 PM Date Paid: Friday, July 07, 2023 Paid By: SOLAR ENERGY LABS INC Pay Method: CREDIT CARD 1115541372 1 of 1 Cashier: TG Cash Register Receipt City of Atlantic Beach Receipt Number R23779 Exp:02/28/2025 Vincen t Mwum vaneza Digitally signed by Vincent Mwumvaneza Date: 2023.06.28 21:47:03 -04'00' By Toni Gindlesperger at 8:59 am, Jun 29, 2023 Reviewed for code compliance CEP BU1699 07/06/2023 8:25:55 PM Exp:02/28/2025 By Toni Gindlesperger at 8:59 am, Jun 29, 2023 Reviewed for code compliance CEP BU1699 07/06/2023 8:26:06 PM Exp:02/28/2025 By Toni Gindlesperger at 9:00 am, Jun 29, 2023 Reviewed for code compliance CEP BU1699 07/06/2023 8:26:13 PM Exp:02/28/2025 By Toni Gindlesperger at 9:00 am, Jun 29, 2023 Reviewed for code compliance CEP BU1699 07/06/2023 8:26:19 PM Domingo A Villaruel:A01410D00000177F3BC588C0001626D Digitally signed by Domingo A Villaruel:A01410D00000177F3BC588C0001626D Date: 2023.06.28 15:37:58 -07'00' By Toni Gindlesperger at 9:00 am, Jun 29, 2023 Reviewed for code compliance CEP BU1699 07/06/2023 8:26:24 PM Domingo A Villaruel:A01410D00000177F3BC588C 0001626D Digitally signed by Domingo A Villaruel:A01410D00000177F3BC588C0001626D Date: 2023.06.28 15:38:09 -07'00' By Toni Gindlesperger at 9:00 am, Jun 29, 2023 Reviewed for code compliance CEP BU1699 07/06/2023 8:26:35 PM Domingo A Villaruel:A01410D00000177F3BC588C0001626D Digitally signed by Domingo A Villaruel:A01410D00000177F3BC588C0001626D Date: 2023.06.28 15:38:17 -07'00' By Toni Gindlesperger at 9:00 am, Jun 29, 2023 Reviewed for code compliance CEP BU1699 07/06/2023 8:26:40 PM Domingo A Villaruel:A01410D00000177F3BC588C 0001626D Digitally signed by Domingo A Villaruel:A01410D00000177F3BC588C0001626D Date: 2023.06.28 15:38:25 -07'00' By Toni Gindlesperger at 9:00 am, Jun 29, 2023 Reviewed for code compliance CEP BU1699 07/06/2023 8:26:45 PM Domingo A Villaruel:A01 410D00000 177F3BC588 C0001626D Digitally signed by Domingo A Villaruel:A01410D00000177F3BC588C0001626D Date: 2023.06.28 15:38:33 -07'00' By Toni Gindlesperger at 9:01 am, Jun 29, 2023 Reviewed for code compliance CEP BU1699 07/06/2023 8:26:52 PM Domingo A Villaruel:A01410D00000177F3BC588C0001626D Digitally signed by Domingo A Villaruel:A01410D00000177F3BC588C0001626D Date: 2023.06.28 15:38:42 -07'00' By Toni Gindlesperger at 9:01 am, Jun 29, 2023 Reviewed for code compliance CEP BU1699 07/06/2023 8:26:57 PM By Toni Gindlesperger at 9:01 am, Jun 29, 2023 By Toni Gindlesperger at 9:01 am, Jun 29, 2023