Loading...
1058 BEACH AVE ROW23-0022 - JB1508666 - ATLANTIC BEACH - CADJB1508666NO EXPECTED CONFLICTSWITH OTHER UTILITIESLOCATION:1058 BEACH AVE, ATLANTIC BEACH,FL 32233TOTAL LENGTH OF JOB: 102' UGJOB DESCRIPTION: CATV DIRECTIONAL BORE PLACEMENTDRAWN BY: SSDATE:SCALE: NTS OF 416/22/2023COMCAST PERMIT REQUEST FOR LOCATION:1058 BEACH AVE, ATLANTIC BEACH, FL 32233THESE PLANS WERE PREPARED UNDER THERESPONSIBLE CHARGE OF COMCAST.SANTA ROSAOKALOOSAWALTONHOLMESWASHINGTONBAYCALHOUNJACKSONGADSDENLIBERTYGULFFRANKLINWAKULLALEONJEFFERSONTAYLORMADISONHAMILTONSUWANNEELAFAYETTEDIXIEGILCHRISTCOLUMBIAUNIONBAKERBRADFORDALACHUALEVYMARIONPUTNAMCLAYDUVALNASSAUST JOHNSFLAGLERVOLUSIALAKESUMTERCITRUSORANGESEMINOLEOSCEOLAPASCOHERNANDOPOLKHILLSBOROUGHPINELLASINDIAN RIVERBREVARDST LUCIEMARTINOKEECHOBEEHIGHLANDSHARDEEMANATEESARASOTADESOTOGLADESCHARLOTTELEEHENDRYPALM BEACHBROWARDCOLLIERMIAMI-DADEMONROEESCAMBIAVICINITY MAP:1058 BEACH AVE, ATLANTIC BEACH, FL 32233DUVAL COUNTY LOCATION:1058 BEACH AVE, ATLANTIC BEACH,FL 32233TOTAL LENGTH OF JOB: 102' UGJOB DESCRIPTION: CATV DIRECTIONAL BORE PLACEMENTDRAWN BY: SSDATE:SCALE: NTS OF 426/22/2023NO EXPECTED CONFLICTSWITH OTHER UTILITIESCOMCAST PERMIT REQUEST FOR LOCATION:1058 BEACH AVE, ATLANTIC BEACH, FL 32233GENERAL NOTES:ALL PROPOSED UNDERGROUND CATV WILL BE BURIED A MINIMUM OF 36" INCLUDING ROAD BORES AND DRIVEWAY BORES.ALL PROPOSED UNDERGROUND CATV ROAD BORES WILL USE CITY APPROVED DIRECTIONAL BORE MACHINE, AS WELL AS COUNTYAPPROVED CONDUIT.ALL PROPOSED CATV ROAD BORES WILL EXTEND A MINIMUM OF 1' BEYOND THE EDGE OF PAVEMENT.ALL PROPOSED CATV DRIVEWAY BORES WILL EXTEND A MINIMUM OF 6' BEYOND THE EDGE OF PAVEMENT.ALL PROPOSED BORES WILL BE IN A (4'X4'X4') PIT AND WILL USE 2" HDPE CONDUIT AT 36" DEPTH USING A5 1/4" DRILL HEAD.ALL PROPOSED AERIAL CATV WILL BE 0.700'' DIAMETER AND WILL BE LASHED TO 0.250" STEEL STRAND CABLEUSING 0.125" STANDARD GALVANIZED LASHING WIRE.ALL PROPOSED AERIAL CATV CROSSING ROADWAYS WILL HAVE A MINIMUM MID-SPAN HEIGHT OF 18'-0".ALL PROPOSED AERIAL CATV CROSSING DRIVEWAYS WILL HAVE A MINIMUM MID-SPAN HEIGHT OF 16'-0".LOCATES WILL BE REQUIRED IN ALL PROPOSED UNDERGROUND AREAS AT LEAST 48 HRS PRIOR TO CONSTRUCTION.NOTIFICATIONS TO ALL UTILITIES INVOLVED WILL BE MADE PRIOR TO CONSTRUCTION.ALL DISTRIBUTED AREA WITHIN THE RIGHT OF WAY WILL BE RESTORED TO ORIGINAL OR BETTER CONDITION BY GRADING ANDRE-SODDING. SOD ALL AREAS DISTURBED BY CONSTRUCTION WITH BERMUDA SOD. "ALL CRACKED SIDEWALKS ARE TO BE REPLACEDFROM JOINT TO JOINT WITHIN 7 DAYS OF WORK COMPLETION."WORK OPERATIONS ARE TO BE MINDFUL NOT TO DAMAGE THE PAVER SIDEWALK WHEN POSITIONING EQUIPMENT. ANY DAMAGEINCLUDING TRACK MARKS WILL BE REPAIRED OR REPLACED BY THE CONTRACTOR.CONSTRUCTION NOTES:IN ORDER TO REDUCE THE DISRUPTION AND COST OF UTILITY DAMAGES OCCURRING IN THE RIGHT-OF-WAY AND EASEMENTS. THEPERMITTEE SHALL PREVENT DAMAGES TO EXISTING UTILITIES CAUSED BY THE WORK THROUGH FIELD VERIFICATION OF THE LOCATIONOF THE EXISTING UTILITIES IN CASE OF OPEN EXCAVATION. VERIFICATION MAY BE PERFORMED DURING THE PERMITTEES WORK. IN THECASE OF DIRECTIONAL DRILLING, VERIFICATION SHALL TAKE PLACE PRIOR TO MOBILIZATION OF THE DRILLING EQUIPMENT.THE PERMITTEE SHALL VERIFY THE LOCATION OF THE EXISTING UTILITIES AS NEEDED TO AVOID CONTACT WITH DETECTION EQUIPMENTOR OTHER ACCEPTABLE MEANS, SUCH METHODS MAY INCLUDE BUT SHALL NOT BE LIMITED TO-"SOFT DIG"-EQUIPMENT AND GROUNDPENETRATION RADAR (GPR). THE EXCAVATOR SHALL BE HELD LIABLE FOR DAMAGES CAUSED TO CITY'S/COUNTY'S/STATEINFRASTRUCTURE AND THE EXISTING FACILITIES OF THE OTHER UTILITY COMPANIES.NO REAMER USEDTHE FOLLOWING STANDARD PLANS ARE IN ACCORDANCE WITH THEFLORIDA DEPARTMENT OF TRANSPORTATION 2022-2023INDEX 102-602 AND APPLY TO:1058 BEACH AVE, ATLANTIC BEACH, FL 32233NO BACKREAMER USEDROAD RIGHT-OF-WAYSANITARY SEWERSTORM SEWERCABLE TV SPAN (EXIST)FENCEGAS PIPELINEOH POWER LINEUG POWER LINEPROPERTY LINEBOTTOM BANKCOMCAST AERIAL ROUTECOMCAST BORE ROUTECABLE TV BORE (EXIST)OH TELEPHONEUG TELEPHONEROAD CENTERLINEFIBER OPTIC CABLEMANHOLE (SANITARY SEWER)CABLE TV PEDESTALMANHOLE (STORM SEWER)SSMHEDGE OF PAVEMENTCABLE TV RISERUTILITY POLEFIRE HYDRANTRAILROAD CENTERLINEELECTRIC PADRAILROAD CROSSING SIGNINLETCATCH BASINWATER VALVERAILROAD CROSSING SIGNALWWATER VAULTTTELEPHONE PEDESTALEVELECTRIC VAULTBORE PITCULVERTWATER MAIN / METERWMSIDEWALKDRIVEWAYUTILITY VAULTVHAND HOLECATV VAULTCV LOCATION:1058 BEACH AVE, ATLANTIC BEACH,FL 32233TOTAL LENGTH OF JOB: 102' UGJOB DESCRIPTION: CATV DIRECTIONAL BORE PLACEMENTDRAWN BY: SSDATE:SCALE: NTS OF 436/22/2023NO EXPECTED CONFLICTSWITH OTHER UTILITIESNO BACKREAMER USED0+00BEGIN UG HEREEXISTING CATV PED1+02END UG HEREEXISTING CATV PEDPROPOSED BORE PLACEMENTFOR 102' ALONG BEACH AVEAT MIN DEPTH OF 36"USING 1-2" 13.5 SDR ROLL PIPEWITH 0.700" COAXIAL CABLEPED -D/WD/WD/WD/WD/WD/W120' ± TO11TH ST120' ± TO10 TH STR/WEOPR/WEOPR/WEOPR/WEOP11'11'18'11'11'5'6'EOP EOP 40'R/W C/LR/W EOPC/L11'11'R/W R/W 0''12''24''36''48''60''72''84''96''108''0''12''24''36''48''60''72''84''96''108''SS EOP 18'3'CATV WATER3'5'6'2'102'10581042BEACH AVE40'40'18'D/WPOLE -107210302'6' SHEET ---- OF XXX OF 44