0 12th Street SURVEYI hereby certify that this Survey of the lands
described hereon was made under my direct
supervision, and to the best of my knowledge
and belief is a true and accurate representation
of said lands and meets the Standards of
Practice set forth in Chapter 5J-15.050 through
5J -15.053, Florida Administrative Code,
pursuant to section 472.027, Florida Statutes.
This survey is not valid without the signature and
original raised seal of a Florida licensed surveyor
and mapper, except when the electronic
signature and seal of a Florida licensed surveyor
and mapper is affixed hereto.
PROPERTY ADDRESS:
DATE SIGNED:
FIELD WORK DATE:
REVISION DATE(S):
POINTS OF INTEREST:SURVEYORS CERTIFICATION:
SURVEY NUMBER:
SEE PAGE 2 OF 2 FOR LEGAL DESCRIPTION
PAGE 1 OF 2 - NOT VALID WITHOUT ALL PAGES
2207.47080 12TH STREET, ATLANTIC BEACH, FLORIDA 32233
07/26/22
7/26/2022
L1
B .R . (A S S U M E D )
SIRC
SIRC
SIRC
UR
1/2" FIRC
LB7337
1/2" FIP
NO ID
@ LOT COR.
UP
1/2" FIRC
LB7337
1/2" FIPC
ILL.
@ PLAT LIMIT
1/2" FIP
NO ID
@ B.C.
LOT 1
BLK 4
LOT 2
BLK 4
LOT 3
BLK 4
VACANT
2
0
.
0
'
LC 12TH STREET (40' R/W)
25.0'
L C
E A S T C O A S T D R I V E (5 0 ' R /W )
6'
W
F
0.3' ON
ON LINE
MANDALAY
P.B. 10, PG. 11
LINE TABLE:
O C E A N B O U L E V A R D
LOT 4, BLK 4
LOT 5, BLK 4
SURVEYOR'S NOTES:
FENCE OWNERSHIP NOT DETERMINED.
C-1
R=
L=
30.00'(P&M)
47.12'(P) 47.85'(M)
C-1
P.C.
P.T.
2207.4708
BOUNDARY SURVEY
DUVAL COUNTY
1 inch = 30' ft.
GRAPHIC SCALE (In Feet)
NONE VISIBLE
(REV.0 7/26/2022)
PROPERTY ADDRESS:
JOB SPECIFIC SURVEYOR NOTES:
LEGAL DESCRIPTION:
GENERAL SURVEYOR NOTES:
SURVEYOR’S LEGEND
CERTIFIED TO:
SEE PAGE 1 OF 2 FOR MAP OF PROPERTY
PAGE 2 OF 2 - NOT VALID WITHOUT ALL PAGES
FLOOD ZONE INFORMATION:
SURVEY NUMBER:
DATE SIGNED:
BUYER:
LENDER:
TITLE COMPANY:
COMMITMENT DATE:CLIENT FILE NO:
2207.4708
0 12TH STREET, ATLANTIC BEACH, FLORIDA 32233
NO CERTS PROVIDED
07/26/22
THE ASSUMED BEARING REFERENCE OF SOUTH 0 DEGREES 04 MINUTES 00 SECONDS EAST IS BASED ON THE EASTERLY PROPERTY LINE OF LOT
1, BLOCK 4, LOCATED WITHIN ATLANTIC BEACH PARKWAY NO. TWO ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 15, PAGE
83 OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA.
LOT ONE, BLOCK FOUR, ATLANTIC BEACH PARKWAY NO. 2. ACCORDING TO PLAT THEREOF RECORDED IN PLAT BOOK 15, PAGE 83, OF THE
CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA.
NO CERTS PROVIDED
NOT REVIEWED
BY PERFORMING A SEARCH WITH THE LOCAL GOVERNING
MUNICIPALITY OR WWW.FEMA.GOV, THE PROPERTY APPEARS TO BE
LOCATED IN ZONE X AND X SHADED. THIS PROPERTY WAS FOUND IN
CITY OF ATLANTIC BEACH, COMMUNITY NUMBER 120075, PANEL
NUMBER 0409 DATED 11/02/2018.
1. The Legal Description used to perform this survey was supplied by others. This survey does not determine nor imply ownership of the lands or any fences shown hereon. Unless the Title Commitment Number is referenced on this survey, an examination of the abstract of title was NOT performed by the signing surveyor to
determine which instruments, if any, are affecting this property.
2. The purpose of this survey is to establish the boundary of the lands described by the legal description provided and to depict the visible improvements thereon for a pending financial transaction. Underground footings, utilities, or other service lines, including roof eave overhangs were not located as part of this survey. Unless specifically stated otherwise the purpose and intent of this survey is not for any construction activities or future planning.
3. If there is a septic tank or drain field shown on this survey, the location depicted hereon was either shown to the
surveyor by a third party or it was estimated by visual above ground inspection. No excavation was performed to determine its location.
4. This survey is exclusively for a pending financial transaction and only to be used by the parties to whom it is certified.
5. Alterations to this survey map and report by other than the signing surveyor are prohibited.
6. Dimensions are in feet and decimals thereof.
7. Any FEMA flood zone data contained on this survey is for informational purposes only. Research to obtain said data was performed at www.fema.gov and may not reflect the
most recent information.
8. Unless otherwise noted “SIRC” indicates a Set Iron Rebar with a Cap stamped LB#8291, a minimum half inch in diameter and eighteen inches long.
9. If you are reading this survey in an electronic format, the information contained on this document is only valid if this
document is electronically signed as specified in Chapter 5J17.062 (3) of the Florida Administrative Code and Florida Statute 472.025. The Electronic Signature File related to this
document is prominently displayed on the invoice for this survey which is sent under separate cover. Manually signed and sealed logs of all survey signature files are kept in the
office of the performing surveyor.
10. The symbols reflected in the legend and on this survey
may have been enlarged or reduced for clarity. The symbols have been plotted at the approximate center of
the field location and may not represent the actual shape or size of the feature.
11. Points of Interest (POI’s) are select above-ground improvements, which may appear in conflict with
boundary, building setback or easement lines, as defined by the parameters of this survey. These POI’s may not represent all items of interest to the viewer. There may be additional POI’s which are not shown or called-out as POI’s, or which are otherwise unknown to the surveyor.
12. Utilities shown on the subject property may or may not indicate the existence of recorded or unrecorded utility easements.
13. The information contained on this survey has been performed exclusively by and is the sole responsibility of Exacta Land Surveyors, LLC. Additional logos or references to third party firms are for informational purposes only.
14. Pursuant to F.S. 558.0035, an individual employee or agent may not be held individually liable for negligence.
15. Due to varying construction standards, building dimensions are approximate and are not intended to be
used for new construction or planning.
LINETYPES
Boundary Line
Center Line
Chain Link or Wire
Fence
Easement
Edge of Water
Iron Fence
Overhead Lines
Structure
Survey Tie Line
Vinyl Fence
Wall or Party Wall
Wood Fence
SURFACE TYPES
Asphalt
Brick or Tile
Concrete
Covered Area
Water
Wood
SYMBOLS
Benchmark
Center Line
Central Angle or
Delta
Common
Ownership
Control Point
Catch Basin
ABBREVIATIONS
(C) - Calculated
(D) - Deed
(F) - Field
(M) - Measured
(P) - Plat
(R) - Record
(S) - Survey
A/C - Air Conditioning
AE - Access Easement
ANE - Anchor Easement
ASBL - Accessory Setback Line
B/W - Bay/Box Window
BC - Block Corner
BFP - Backflow Preventer
BLDG - Building
BLK - Block
BM - Benchmark
BR - Bearing Reference
BRL - Building Restriction Line
BSMT - Basement
C - Curve
C/L - Center Line
Elevation
Fire Hydrant
Find or Set
Monument
Guywire or Anchor
Manhole
Tree
Utility or Light Pole
Well
C/P - Covered Porch
C/S - Concrete Slab
CATV - Cable TV Riser
CB - Concrete Block
CH - Chord Bearing
CHIM - Chimney
CLF - Chain Link Fence
CME - Canal Maintenance
Easement
CO - Clean Out
CONC - Concrete
COR - Corner
CS/W - Concrete Sidewalk
CUE - Control Utility Easement
CVG - Concrete Valley Gutter
D/W - Driveway
DE - Drainage Easement
DF - Drain Field
DH - Drill Hole
DUE - Drainage & Utility Easement
ELEV - Elevation
EM - Electric Meter
ENCL - Enclosure
ENT - Entrance
EOP - Edge of Pavement
EOW - Edge of Water
ESMT - Easement
EUB - Electric Utility Box
F/DH - Found Drill Hole
FCM - Found Concrete
Monument
FF - Finished Floor
FIP - Found Iron Pipe
FIPC - Found Iron Pipe & Cap
FIR - Found Iron Rod
FIRC - Found Iron Rod & Cap
FN - Found Nail
FN&D - Found Nail & Disc
FRRSPK - Found Rail Road Spike
GAR - Garage
GM - Gas Meter
ID - Identification
IE/EE - Ingress/Egress Easement
ILL - Illegible
INST - Instrument
INT - Intersection
IRRE - Irrigation Easement
L - Length
LAE - Limited Access Easement
LB# - License No. (Business)
LBE - Limited Buffer Easement
LE - Landscape Easement
LME - Lake/Landscape Maintenance Easement
LS# - License No. (Surveyor)
MB - Map Book
ME - Maintenance Easement
MES - Mitered End Section
MF - Metal Fence
MH - Manhole
MHWL - Mean High Water Line
NR - Non-Radial
NTS - Not to Scale
NAVD88 - North American
Vertical Datum 1988
NGVD29 - National Geodetic
Vertical Datum 1929
OG - On Ground
ORB - Official Records Book
ORV - Official Record Volume
O/A - Overall
O/S - Offset
OFF - Outside Subject Property
OH - Overhang
OHL - Overhead Utility Lines
OHWL - Ordinary High Water
Line
ON - Inside Subject Property
P/E - Pool Equipment
PB - Plat Book
PC - Point of Curvature
PCC - Point of Compound Curvature
PCP - Permanent Control Point
PI - Point of Intersection
PLS - Professional Land Surveyor
PLT - Planter
POB - Point of Beginning
POC - Point of Commencement
PRC - Point of Reverse Curvature
PRM - Permanent Reference Monument
PSM - Professional Surveyor
& Mapper
PT - Point of Tangency
PUE - Public Utility Easement
R - Radius or Radial
R/W - Right of Way
RES - Residential
RGE - Range
ROE - Roof Overhang Easement
RP - Radius Point
S/W - Sidewalk
SBL - Setback Line
SCL - Survey Closure Line
SCR - Screen
SEC - Section
SEP - Septic Tank
SEW - Sewer
SIRC - Set Iron Rod & Cap
SMWE - Storm Water Management Easement
SN&D - Set Nail and Disc
SQFT - Square Feet
STL - Survey Tie Line
STY - Story
SV - Sewer Valve
SWE - Sidewalk Easement
TBM - Temporary Bench Mark
TEL - Telephone Facilities
TOB - Top of Bank
TUE - Technological Utility Easement
TWP - Township
TX - Transformer
TYP - Typical
UE - Utility Easement
UG - Underground
UP - Utility Pole
UR - Utility Riser
VF - Vinyl Fence
W/C - Witness Corner
W/F - Water Filter
WF - Wood Fence
WM - Water Meter/Valve Box
WV - Water valve