759 Sailfish Dr ROOF23-0054 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP:
BARTLEY LAWILDA 4424 ELLIPSE DR JACKSONVILLE FL 32246
COMPANY:ADDRESS:CITY:STATE:ZIP:
Roofcrafters Roofing, LLC 12724 GranBay Parkway #410 Jacksonville FL 32258
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
171236 0000 ROYAL PALMS UNIT 01
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
759 SAILFISH DR ROOF NON SHINGLE CERTAINTEED FLINTASTIC
MODBIT $7100.00
FEES
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL
Notes:
a.\tThe roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved.\r\r
b.\tAll roofing projects require an In-Progress Inspection.\r\r
c.\tSheathing installation and replacement guidelines per APA.\r\r
d.\tUnderlayment must conform to FBC-R Table 905.1.1\r\r
e.\tShingles must conform to ASTM D3161 G or H, or ASTM D7158 F\r\r
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 7/17/2023
PERMIT NUMBER
ROOF23-0054
ISSUED: 7/17/2023
EXPIRES: 1/13/2024
ROOF NON SHINGLE PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $90.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $45.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.03
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL: $139.03
2 of 2Issued Date: 7/17/2023
PERMIT NUMBER
ROOF23-0054
ISSUED: 7/17/2023
EXPIRES: 1/13/2024
ROOF NON SHINGLE PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
Final Plumbing
Final Electrical
Final HVAC
CC Final
Final Building*
Swimming Pool Steel
Swimming Pool Safety
Electrical Grounding & Bonding
Swimming Pool Final (Bldg)
Swimming Pool Final (PW)
Formed Columns/ Beams*
Masonry Cell Fill
Structural Steel*
OTHER:
OTHER:
OTHER:
OTHER:
OTHER:
Power Pole
Silt Fence
Piers/ Stem Walls
Underground Plumbing
Underground Electric
Foundation/ Footing
Slab**
Retaining Wall Footing
Driveway
Sewer (Building Dept)
Sewer Tap (Utilities Dept)
Rough Electric*
Rough Plumbing/ Top Out*
Rough Mechanical*
House Wrap
Wall Sheathing
Roof Sheathing
Tie-down Framing Connections
Rough Framing
Roofing In Progress
Window/Door In-Progress
Insulation Ceiling
Insulation Wall
Exterior Lath
Stucco Scratch Coat
Exterior Siding In-Progress
Brick Flashing & Ties
Early Power
Gas Rough
Gas Final*
* When all rough electric, plumbing, mechanical are complete but before any work is
covered up.
* When all gas piping is complete and wallboard is installed but before gas is
attached to any appliance. All outlets must be capped and pipe pressurized at a
minimum of 15 lbs.
* For new living space: When all construction work including electrical, plumbing,
mechanical, exterior finish, grading, required paving and landscaping is complete
and the building is ready for occupancy, but before being occupied
Additional inspections may apply to your project if your project
contains these elements:
INSPECTIONS REQUIRED FOR BUILDING PERMITS
To verify compliance with building codes, inspections of the work authorized are required at various points of the construction.
The following inspections are typically required for residential projects:
Date: Initial: Date: Initial:
_____________________________________________________
Permit Type
____________________________________________________
Permit No.
__________________________________________________________
Job Address
____________________________________________________
Contractor
POST THIS CARD WITH PERMITS AND PERMIT
DOCUMENTATION IN FRONT OF BUILDING
Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends
Building Department Public Works/Utilities Fire Department
Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789
Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203
* When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all
electrical, plumbing and mechanical work is in place, but before concrete is poured.
* When all structural steel members are in place and all connections are complete,
but before such work is covered or concealed.
** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION
CERTAINTEED FLINTASTIC MODBIT
759 SAILFISH DR
Roofcrafters Roofing, LLC
ROOF23-0054
ROOF23-0054
ROOF23-0054
NOA No.: 19-0610.05
Expiration Date: 08/29/24
Approval Date: 08/29/19
Page 1 of 6
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
CertainTeed Corporation
20 Moores Road
Malvern, PA 19355
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in
Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code including
the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: CertainTeed BUR and Modified Bitumen Roofing Membranes
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,
use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales,
advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA
shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in
its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
This NOA consists of pages 1 through 6.
The submitted documentation was reviewed by Alex Tigera.
ROOF23-0054
NOA No.: 19-0610.05
Expiration Date: 08/29/24
Approval Date: 08/29/19
Page 2 of 6
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Roofing Membranes and Accessories
Material: BUR and Modified Bitumen Roofing
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
SBS: MODIFIED BITUMEN MEMBRANES
Product
Dimensions
Test
Specifications
Product Description
Black Diamond™ Base Sheet
Manufacturing location: #2
36" x 68’7” ASTM D1970
ASTM D4601,
Type I
Self-adhering fiberglass reinforced modified
bitumen base sheet.
Flintlastic Ultra Glass SA
Manufacturing location: #1
39 3/8” x 33’11” ASTM D6163
Self-adhering, fiberglass reinforced, SBS
modified bitumen base/ply sheet.
All Weather/Empire Base
Sheet
Manufacturing location: #1
39 3/8" x 65’10” ASTM D4601,
Type II
Asphalt coated, fiberglass reinforced base sheet.
Flexiglas Base Sheet
Manufacturing location: #1
39 3/8" x 98’9” ASTM D4601,
Type II
Modified Bitumen coated fiberglass base sheet.
Flintlastic Poly SMS Base
Sheet
Manufacturing location: #1
39 3/8" x 64' 3"
ASTM D4601,
Grade S, Type II
UL Type G2
Modified Bitumen coated polyester base sheet.
Flintlastic Ultra Poly SMS
Base Sheet
Manufacturing location: #1
39 3/8” x 32’10” ASTM D6164
Grade S, Type I
SBS modified, polyester reinforced base/ply
sheet.
Flintlastic Base 20
Manufacturing location: #1
39 3/8” x 49’6” ASTM D6163
Grade S, Type I
SBS modified, fiberglass reinforced base/ply
sheet.
Flintlastic Base 20 T
Manufacturing location: #1
39 3/8” x 33’ ASTM D 6163,
Grade S, Type I
Modified Bitumen, coated fiberglass base sheet
for torch application.
Flintlastic FR Cap 30
Manufacturing location: #1
39 3/8" x 32' 10" ASTM D 6163,
Grade G, Type I
Fire resistant, granule surfaced SBS Modified
Bitumen membrane with fiberglass mat
reinforcement for mop applications.
Flintlastic FR Cap 30 T
Manufacturing location: #1
39 3/8” x 32’10” ASTM D 6163,
Grade G, Type I
Granule surfaced SBS Modified Bitumen
membrane with fiberglass mat reinforcement for
torch application.
NOA No.: 19-0610.05
Expiration Date: 08/29/24
Approval Date: 08/29/19
Page 3 of 6
Flintlastic GMS
Manufacturing location: #1
39 3/8" x 32' 10" ASTM D 6164,
Grade G, Type I
Granule surfaced SBS Modified Bitumen
membrane with non-woven polyester mat
reinforcement for mop application.
Flintlastic FR-P
Manufacturing location: #1
39 3/8" x 32' 10" ASTM D 6164,
Grade G, Type I
Granule surfaced SBS Modified Bitumen
membrane with non-woven polyester mat
reinforcement for mop application.
Flintlastic Premium FR-P
Manufacturing location: #1
39 3/8" x 32’ 10” ASTM D 6164,
Grade G, Type II
Fire resistant, granule surfaced SBS Modified
Bitumen Membrane with non-woven polyester
mat reinforcement for mop application.
SBS: SELF-ADHERED MEMBRANES
Product
Dimensions
Test
Specifications
Product Description
Flintlastic SA NailBase
Manufacturing location: #1
39 3/8” x 66’6” ASTM D4601,
Type II
Fiberglass reinforced, SBS modified bitumen
base sheet.
Flintlastic SA PlyBase
Manufacturing location: #1
39 3/8” x 66’6” ASTM D4601,
Grade S, Type II
Self-adhering, fiberglass reinforced, SBS
modified bitumen base/ply sheet.
Flintlastic SA Mid Ply
Manufacturing location: #1
39 3/8” x 32’1” ASTM D 6163,
Grade S, Type I
Self-adhering, polyester reinforced, SBS
modified bitumen ply sheet.
Flintlastic SA Cap
Manufacturing location: #1
39 3/8” x 32’11” ASTM D 6164,
Grade G, Type I
Self-adhering, polyester reinforced, SBS
modified bitumen cap sheet.
Flintlastic SA Cap FR
Manufacturing location: #1
39 3/8” x 32’11” ASTM D 6163,
Grade G, Type I
Self-adhering, fiberglass reinforced, SBS
modified bitumen cap sheet.
APP:MODIFIED BITUMEN MEMBRANES
Product
Dimensions
Test
Specifications
Product Description
Flintlastic APP Base T
Manufacturing location: #1
39 3/8” x 65’ 4” ASTM D6509 Modified Bitumen coated fiberglass base sheet.
Flintlastic STA
Manufacturing location: #1
39 3/8" x 32’10” ASTM D 6222,
Grade S, Type I
Smooth surfaced APP Modified Bitumen
membrane with non-woven polyester mat
reinforcement for torch application.
Flintlastic GTA
Manufacturing location: #1
39 3/8" x 32' 10" ASTM D 6222,
Grade G, Type I
Granule surfaced APP Modified Bitumen
membrane with non-woven polyester mat
reinforcement for torch application.
Flintlastic GTA-FR
Manufacturing location: #1
39 3/8" x 32’ 10" ASTM D 6222,
Grade G, Type I
Granule surfaced APP Modified Bitumen
membrane with non-woven polyester mat
reinforcement for torch application.
NOA No.: 19-0610.05
Expiration Date: 08/29/24
Approval Date: 08/29/19
Page 4 of 6
BUILT-UP ROOFING MEMBRANES
Product
Dimensions
Test
Specifications
Product Description
Glasbase Base Sheet
Manufacturing location: #1
39 3/8" x 98’9” ASTM D4601
Type II
UL Type G2
Asphalt coated, fiberglass base sheet.
Flintglas Ply 4
Manufacturing location: #3
39 3/8" x 164’7” ASTM D2178,
Type IV
UL Type G1
Fiberglass, asphalt impregnated ply sheet.
Flintglas Premium Ply 6
Manufacturing location: #3
39 3/8" x 164’7” ASTM D2178,
Type VI
UL Type G1
Fiberglass, asphalt impregnated ply sheet.
Yosemite Venting Base Sheet
Manufacturing location: #1
39 3/8" x 32’10” ASTM D3909
ASTM D4897,
Type II UL G3
Mineral Surfaced fiberglass reinforced buffer
sheet.
Flintglas MS Cap Sheet
Manufacturing location: #1
39 3/8" x 32’10” ASTM D3909
UL Type G3
Asphalt impregnated and coated inorganic
glass fiber surfaced with mineral granules used
as the top ply in conventional built-up roof
membranes.
MANUFACTURING LOCATIONS:
1. Little Rock, AR
2. Shakopee, MN
3. Shreveport, LA
NOA No.: 19-0610.05
Expiration Date: 08/29/24
Approval Date: 08/29/19
Page 5 of 6
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
PRI Construction Materials ASTM D6163 CTC-066-02-01 2011-08-08
Technologies LLC ASTM D6222 CTC-071-02-01 2011-08-08
ASTM D6164 CTC-093-02-01 2011-08-08
ASTM D2178 CTC-123-02-01 2012-03-12
ASTM D4601 CTC-124-02-01 2012-03-12
ASTM D4601 CTC-126-02-01 2012-03-12
ASTM D6509 CTC-116-02-01 2012-04-04
ASTM D6163 CTC-128-02-01 2012-06-08
ASTM D6163 CTC-129-02-01 2012-06-08
ASTM D6164 CTC-131-02-01 2012-06-08
ASTM D6164 CTC-161-02-01 2013-05-09
ASTM D6164 CTC-190-02-01 2013-11-27
ASTM D6163 CTC-319-02-01 2017-08-22
ASTM D4601 CTC-321-02-01 2017-08-22
ASTM D6164 CTC-354-02-01 2018-05-11
Trinity|ERD ASTM D6222 C40050.12.13-R1 2013-12-05
ASTM D6163 C45110.01.14 2014-01-20
ASTM D2178 C47250.03.14 2014-03-26
ASTM D4601 CTR-SC8740.04.15-R2 2015-04-30
ASTM D6163 CTR-SC11145.09.16-5B 2016-09-16
ASTM D3909 CTR-SC11145.09.16-2A 2016-09-19
ASTM D3909 CTR-SC11145.09.16-2B 2016-09-19
ASTM D4601 CTR-SC11145.09.16-3A 2016-09-19
ASTM D4601 CTR-SC11145.09.16-3B 2016-09-19
ASTM D4601 CTR-SC11145.09.16-3C 2016-09-19
ASTM D4897 CTR-SC11145.09.16-4 2016-09-19
ASTM D6163 CTR-SC11145.09.16-5A 2016-09-19
ASTM D6222 CTR-SC11145.09.16-7A 2016-09-19
LABELING:
All membranes and accessories or packaging shall bear the imprint or identifiable marking of the manufacturer's name or
logo, city and state of manufacturing facility, and the following statement: "Miami-Dade County Product Control
Approved" or the Miami-Dade County Product Control Seal as shown below.
NOA No.: 19-0610.05
Expiration Date: 08/29/24
Approval Date: 08/29/19
Page 6 of 6
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. CertainTeed BUR and Modified Bitumen Roofing Membranes are designed for use as specified within approved
roofing system NOA assemblies.
3. This acceptance establishes the required physical properties testing and traceability of roofing membrane and
accessory components listed in approved roofing applications. Minimum deck requirements shall be in compliance
with applicable building code. CertainTeed BUR and Modified Bitumen Roofing Membranes shall be installed in
strict compliance with applicable Building Codes, Product Approvals and Manufacturers’ specifications and
guidelines.
4. Change in materials or manufacturing process or location of any of the products listed herein shall be cause for
termination of this Notice of Acceptance.
5. CertainTeed BUR and Modified Bitumen Roofing Membranes may be used with any approved Roof Assembly
Notice of Acceptance listing CertainTeed BUR and Modified Bitumen Roofing Membranes as a component part of
an assembly in the Notice of Acceptance. If CertainTeed BUR and Modified Bitumen Roofing Membranes is not
listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product
Control Department for approval, provided that appropriate documentation is provided to detail compatibility of the
products, wind uplift resistance, and fire testing results.
6. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE