Loading...
900 Plaza ROOF23-0056 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: SEA OATS ACQUISITION LLC 645 MAYPORT RD STE 5 ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: Roofcrafters Roofing, LLC 12724 GranBay Parkway #410 Jacksonville FL 32258 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 171725 0500 ROYAL PALMS ACRES JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 900 PLAZA ROOF NON SHINGLE COMMERCIAL BUILDING 9 - SHINGLE AND MODIFIED ROOF $33546.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: a.\tThe roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved.\r\r b.\tAll roofing projects require an In-Progress Inspection.\r\r c.\tSheathing installation and replacement guidelines per APA.\r\r d.\tUnderlayment must conform to FBC-R Table 905.1.1\r\r e.\tShingles must conform to ASTM D3161 G or H, or ASTM D7158 F\r\r NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 7/25/2023 PERMIT NUMBER ROOF23-0056 ISSUED: 7/25/2023 EXPIRES: 1/21/2024 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $220.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $110.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $4.95 STATE DCA SURCHARGE 455-0000-208-0600 0 $3.30 TOTAL: $338.25 2 of 2Issued Date: 7/25/2023 PERMIT NUMBER ROOF23-0056 ISSUED: 7/25/2023 EXPIRES: 1/21/2024 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION COMMERCIAL BUILDING 9 - SHINGLE AND MODIFIED ROOF 900 PLAZA Roofcrafters Roofing, LLC ROOF23-0056 ROOF23-0056 BUILDING 9 ROOF23-0056 NOA No.: 19-0610.05 Expiration Date: 08/29/24 Approval Date: 08/29/19 Page 1 of 6 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy CertainTeed Corporation 20 Moores Road Malvern, PA 19355 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CertainTeed BUR and Modified Bitumen Roofing Membranes LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. NOA No.: 19-0610.05 Expiration Date: 08/29/24 Approval Date: 08/29/19 Page 2 of 6 ROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Roofing Membranes and Accessories Material: BUR and Modified Bitumen Roofing TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: SBS: MODIFIED BITUMEN MEMBRANES Product Dimensions Test Specifications Product Description Black Diamond™ Base Sheet Manufacturing location: #2 36" x 68’7” ASTM D1970 ASTM D4601, Type I Self-adhering fiberglass reinforced modified bitumen base sheet. Flintlastic Ultra Glass SA Manufacturing location: #1 39 3/8” x 33’11” ASTM D6163 Self-adhering, fiberglass reinforced, SBS modified bitumen base/ply sheet. All Weather/Empire Base Sheet Manufacturing location: #1 39 3/8" x 65’10” ASTM D4601, Type II Asphalt coated, fiberglass reinforced base sheet. Flexiglas Base Sheet Manufacturing location: #1 39 3/8" x 98’9” ASTM D4601, Type II Modified Bitumen coated fiberglass base sheet. Flintlastic Poly SMS Base Sheet Manufacturing location: #1 39 3/8" x 64' 3" ASTM D4601, Grade S, Type II UL Type G2 Modified Bitumen coated polyester base sheet. Flintlastic Ultra Poly SMS Base Sheet Manufacturing location: #1 39 3/8” x 32’10” ASTM D6164 Grade S, Type I SBS modified, polyester reinforced base/ply sheet. Flintlastic Base 20 Manufacturing location: #1 39 3/8” x 49’6” ASTM D6163 Grade S, Type I SBS modified, fiberglass reinforced base/ply sheet. Flintlastic Base 20 T Manufacturing location: #1 39 3/8” x 33’ ASTM D 6163, Grade S, Type I Modified Bitumen, coated fiberglass base sheet for torch application. Flintlastic FR Cap 30 Manufacturing location: #1 39 3/8" x 32' 10" ASTM D 6163, Grade G, Type I Fire resistant, granule surfaced SBS Modified Bitumen membrane with fiberglass mat reinforcement for mop applications. Flintlastic FR Cap 30 T Manufacturing location: #1 39 3/8” x 32’10” ASTM D 6163, Grade G, Type I Granule surfaced SBS Modified Bitumen membrane with fiberglass mat reinforcement for torch application. NOA No.: 19-0610.05 Expiration Date: 08/29/24 Approval Date: 08/29/19 Page 3 of 6 Flintlastic GMS Manufacturing location: #1 39 3/8" x 32' 10" ASTM D 6164, Grade G, Type I Granule surfaced SBS Modified Bitumen membrane with non-woven polyester mat reinforcement for mop application. Flintlastic FR-P Manufacturing location: #1 39 3/8" x 32' 10" ASTM D 6164, Grade G, Type I Granule surfaced SBS Modified Bitumen membrane with non-woven polyester mat reinforcement for mop application. Flintlastic Premium FR-P Manufacturing location: #1 39 3/8" x 32’ 10” ASTM D 6164, Grade G, Type II Fire resistant, granule surfaced SBS Modified Bitumen Membrane with non-woven polyester mat reinforcement for mop application. SBS: SELF-ADHERED MEMBRANES Product Dimensions Test Specifications Product Description Flintlastic SA NailBase Manufacturing location: #1 39 3/8” x 66’6” ASTM D4601, Type II Fiberglass reinforced, SBS modified bitumen base sheet. Flintlastic SA PlyBase Manufacturing location: #1 39 3/8” x 66’6” ASTM D4601, Grade S, Type II Self-adhering, fiberglass reinforced, SBS modified bitumen base/ply sheet. Flintlastic SA Mid Ply Manufacturing location: #1 39 3/8” x 32’1” ASTM D 6163, Grade S, Type I Self-adhering, polyester reinforced, SBS modified bitumen ply sheet. Flintlastic SA Cap Manufacturing location: #1 39 3/8” x 32’11” ASTM D 6164, Grade G, Type I Self-adhering, polyester reinforced, SBS modified bitumen cap sheet. Flintlastic SA Cap FR Manufacturing location: #1 39 3/8” x 32’11” ASTM D 6163, Grade G, Type I Self-adhering, fiberglass reinforced, SBS modified bitumen cap sheet. APP:MODIFIED BITUMEN MEMBRANES Product Dimensions Test Specifications Product Description Flintlastic APP Base T Manufacturing location: #1 39 3/8” x 65’ 4” ASTM D6509 Modified Bitumen coated fiberglass base sheet. Flintlastic STA Manufacturing location: #1 39 3/8" x 32’10” ASTM D 6222, Grade S, Type I Smooth surfaced APP Modified Bitumen membrane with non-woven polyester mat reinforcement for torch application. Flintlastic GTA Manufacturing location: #1 39 3/8" x 32' 10" ASTM D 6222, Grade G, Type I Granule surfaced APP Modified Bitumen membrane with non-woven polyester mat reinforcement for torch application. Flintlastic GTA-FR Manufacturing location: #1 39 3/8" x 32’ 10" ASTM D 6222, Grade G, Type I Granule surfaced APP Modified Bitumen membrane with non-woven polyester mat reinforcement for torch application. NOA No.: 19-0610.05 Expiration Date: 08/29/24 Approval Date: 08/29/19 Page 4 of 6 BUILT-UP ROOFING MEMBRANES Product Dimensions Test Specifications Product Description Glasbase Base Sheet Manufacturing location: #1 39 3/8" x 98’9” ASTM D4601 Type II UL Type G2 Asphalt coated, fiberglass base sheet. Flintglas Ply 4 Manufacturing location: #3 39 3/8" x 164’7” ASTM D2178, Type IV UL Type G1 Fiberglass, asphalt impregnated ply sheet. Flintglas Premium Ply 6 Manufacturing location: #3 39 3/8" x 164’7” ASTM D2178, Type VI UL Type G1 Fiberglass, asphalt impregnated ply sheet. Yosemite Venting Base Sheet Manufacturing location: #1 39 3/8" x 32’10” ASTM D3909 ASTM D4897, Type II UL G3 Mineral Surfaced fiberglass reinforced buffer sheet. Flintglas MS Cap Sheet Manufacturing location: #1 39 3/8" x 32’10” ASTM D3909 UL Type G3 Asphalt impregnated and coated inorganic glass fiber surfaced with mineral granules used as the top ply in conventional built-up roof membranes. MANUFACTURING LOCATIONS: 1. Little Rock, AR 2. Shakopee, MN 3. Shreveport, LA NOA No.: 19-0610.05 Expiration Date: 08/29/24 Approval Date: 08/29/19 Page 5 of 6 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials ASTM D6163 CTC-066-02-01 2011-08-08 Technologies LLC ASTM D6222 CTC-071-02-01 2011-08-08 ASTM D6164 CTC-093-02-01 2011-08-08 ASTM D2178 CTC-123-02-01 2012-03-12 ASTM D4601 CTC-124-02-01 2012-03-12 ASTM D4601 CTC-126-02-01 2012-03-12 ASTM D6509 CTC-116-02-01 2012-04-04 ASTM D6163 CTC-128-02-01 2012-06-08 ASTM D6163 CTC-129-02-01 2012-06-08 ASTM D6164 CTC-131-02-01 2012-06-08 ASTM D6164 CTC-161-02-01 2013-05-09 ASTM D6164 CTC-190-02-01 2013-11-27 ASTM D6163 CTC-319-02-01 2017-08-22 ASTM D4601 CTC-321-02-01 2017-08-22 ASTM D6164 CTC-354-02-01 2018-05-11 Trinity|ERD ASTM D6222 C40050.12.13-R1 2013-12-05 ASTM D6163 C45110.01.14 2014-01-20 ASTM D2178 C47250.03.14 2014-03-26 ASTM D4601 CTR-SC8740.04.15-R2 2015-04-30 ASTM D6163 CTR-SC11145.09.16-5B 2016-09-16 ASTM D3909 CTR-SC11145.09.16-2A 2016-09-19 ASTM D3909 CTR-SC11145.09.16-2B 2016-09-19 ASTM D4601 CTR-SC11145.09.16-3A 2016-09-19 ASTM D4601 CTR-SC11145.09.16-3B 2016-09-19 ASTM D4601 CTR-SC11145.09.16-3C 2016-09-19 ASTM D4897 CTR-SC11145.09.16-4 2016-09-19 ASTM D6163 CTR-SC11145.09.16-5A 2016-09-19 ASTM D6222 CTR-SC11145.09.16-7A 2016-09-19 LABELING: All membranes and accessories or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. NOA No.: 19-0610.05 Expiration Date: 08/29/24 Approval Date: 08/29/19 Page 6 of 6 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. CertainTeed BUR and Modified Bitumen Roofing Membranes are designed for use as specified within approved roofing system NOA assemblies. 3. This acceptance establishes the required physical properties testing and traceability of roofing membrane and accessory components listed in approved roofing applications. Minimum deck requirements shall be in compliance with applicable building code. CertainTeed BUR and Modified Bitumen Roofing Membranes shall be installed in strict compliance with applicable Building Codes, Product Approvals and Manufacturers’ specifications and guidelines. 4. Change in materials or manufacturing process or location of any of the products listed herein shall be cause for termination of this Notice of Acceptance. 5. CertainTeed BUR and Modified Bitumen Roofing Membranes may be used with any approved Roof Assembly Notice of Acceptance listing CertainTeed BUR and Modified Bitumen Roofing Membranes as a component part of an assembly in the Notice of Acceptance. If CertainTeed BUR and Modified Bitumen Roofing Membranes is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for approval, provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 6. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE