Loading...
439 IREX RD RESA23-0008 - Form r402-2020 webb Rev. 7-3-23_1APPENDIX RD — FORMS FLORIDA BUILDING CODE, ENERGY CONSERVATION Residential Building Thermal Envelope Approach R -Value Computation Method FORM 8402-2020 (with 2022 Supplement) Florida Climate Zone PROJECT NAME FENESTRATION AND ADDRESS: PERMITTING OFFICE: CEILING JURISDICTION NUMBER: OWNER: PERMIT NUMBER: PERMIT TYPE: NUMBER OF UNITS: WORST CASE? CONDITIONED FLOOR AREA: Scope: Compliance with Section R402.1.2 of the Florida Building Code, Energy Conservation, shall be demonstrated by the use of Form 8402 for single- and multiple -family residences of three stories or less in height, additions to existing residential buildings, alterations, renovations and building systems in existing buildings, as applicable. To comply, a building must meet or exceed all of the energy efficiency requirements and applicable mandatory requirements summarized on this form. It a building does not comply with this method, or by the UA Alternative method, it may still comply under Section R405 or 8406 of the Florida Building Code, Energy Conservation. General I n structi ons: 1. Fill in all the applicable spaces of the "INSTALLED" row In the INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT table with the information requested. All 'INSTALLED" values must be equal to or more efficient than the required levels. "AVG" Indicates an area weighted average is allowed; "LOWEST" indicates the lowest R -value to be inetalled must be entered. 2. Complete the tables for air infiltration and installed equipment. 3. Read the MANDATORY REQUIREMENTS table and check each box to indicate your intent to comply with all applicable Items. 4. Read, sign and date the "Prepared By" certification statement at the bottom of this form. The owner or owner's agent must also sign and date the form. INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT' REQUIREMENTS FENESTRATION SKYLIGHT' GLAZED CEILING WOOD FRAME MASS WALL FLOOR BASEMENT SLAB'A• CRAWL SPACE t4FACTORI 1' i4FACTOR FENESTRATION SHGC­ WALL R• R -VALUE- R -VALUE WALL R- VALUE WALL R• VALUE' VALUE' VALUE DEPTH VALUE CLIMATE ZONE 1 NR 0.75 0,25 30 13 314 13 0 0 0 CLIMATE ZONE 2 0.40 0.65 0,25 36 13 416 13 0 0 0 VALUE AVG AVG AVG LOWEST LOWEST LOWEST LOWEST LOWEST LOWEST LOWEST INSTALLED: R -Value Calculation Method - [PASS t FAIL] For SI: 1 foot = 304.6 mm: NR m No requirement 0) R -values are minimums. LA -factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the instalted ci-value of the insulation shall not be less than the R -value specified in thetable. (2) The fenestration U -factor column excludes skylights. The SHGC column applies to all glazed fenestration. Exception: Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1 through 3 where the SHGC for such skylights does not exceed 0.30. (3) For impact rated fenestration complying with Section 8301.2.1.2 of the Florida Building Code, Residential or Section 1609. 1,2 of the Florida Building Cade, Building, the maximum U -factor shall be 0.65 in Climate Zone 2. An area -weighted average of (-factor and SHGC shall be accepted to meet the requirements, and up to 15 square feet of glazed fenestration area are exempted from the bLiactor and SHGC requirement based on Section R402.3.1, R402.3.2 and R402.3.3. (4) One side -hinged opaque door assembly up to 24 square feet is exempted from this Lf -factor requirement based on Section R402.3.4. (5) R -values are for insulation material only as applied in accordance with manufacturer's installation instructions. 16) The second R -value applies when more than Half the insulation is on the interior of the mass wall. 7) R-5 shall be added to the required siab edge R -values for heated slabs. Insulation depth shall be the depth of the fooling or 2 feet, whichever is less in Climate Zones 1 through 3 for heated slabs. B€ower door test is required on the budding envelope to verify leakage 7 ACH50i lest report must be provided to code official before Air infiltration: CO is issued. Flonda Burldmg Code, Energy Conservation Section R402.4.1 2 testing exception may apply for additions, alterations. or renovations (continued) FLORIDA BUILDING CODE — ENERGY CONSERVATION, 7th EDITION (2020) R-57 APPENDI%RD — FORMS FORM R402—cominued EQUIPMENT REQUIREMENTS AND INSTALLED VALUES Fill In the "INSTALLED EFFICIENCY LEVEL" column with the informatlon requested. For multiple systems of the same type, indicate the minimum efficient system. All "INSTALLED" values must be equal to or more efficient than the required level. 8 a listed "SYSTEM TYPE" Is not to be installed, write In "WA" for not applicable. SYSTEM TYPE MINIMUM EFFICIENCY LEVEL REQUIRED INSTALLED EFFICIENCY LEVEL Air distribution system' Not allowed in attic Location: Air handling unit Factory Scaled Factory Sealed? YM Dud R -value = R-8 (Ducts in unconditioned attics, Diameter z 3 in.) R -Value (In unc. attic) _ = R-6 (Ducts in unconditioned! non attics, Diam. , 3 in.) R -Value (In unc. non attics) = R-6 (Ducts in unconditioned attics, Diameter < 3 in.) R -Value (Small ducts in attic) = = R-4.2 (Duds in unconditioned not attics, Clam. < 3 in.) R -Value (Small duds in unc) = All duds am in conditioned space (No minimum) All in conditioned space? YM Air leakage Dud test Air handler installed: Total leakage = 4 chil s.f. Air handier not Installed: Total leakage = 3 ch ill00 s.i. Total leakage = eIM100 s.f. Air handier installed? Y/N Dud testing Test not required if all duds and AHU are within the building thermal envelope and for additions or alterations where duds extended from existing heating and Test report required? Y/N cooling system through unconditioned space are <40linear n. Air condtioning systems: Minimum federal standard required by NAECk: Central system c 45,000 BiWh SEER2 =14.3 Cap. (Blunt)= Central system> 45,000 Btum SEER2=13.8 SEER2 (Min)= Central heat pump SEEF1214.3 SEER2 (Min)= EER (Min)= PTAC EER [from Table C403.2.3(3)] Other. See Tables C403.2.3(1)-(1 1) = TypeEffie. (min) Heating systems: Minimum federal standard required by NAECA': Heat pump 65,000 BW/h HSPFz 8.2 HSPF(Min)= Gas fumace, non -weatherized AFUEz 80% AFUE(Min)= Oil furnace, non-weathenzed AFUE z 83% AFUE (Min) = Other: Type= Effie. (min) Water heating system (storage type): Minimum federal standard required by NAECR: Capacity = Electric" UEF 40 gal. 0.923; 50 gal.: 0.921; 80 gal.: 2.051 UEF(Min)- Gas fired'UEF 40 gal. 0.580; 50 gal.: 0.563; 60 gel.: 0.766 UEF (Min) = Other (describe)'-°: Type= Effie. Equipment Efficiency—IPASS / FAIL] (1) Duds 8 AHU installad'substantiallyy leak free' per Section 8403.3 2. Test required by etther individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as ser fold in Sedien 489,105(3)(0, (g), m (i), Flontla Statutes. The total leakage test is not required for duds and air handlers located entirely within the building thermal envelope, and for additions where duds from an existing heeling and cooling system extended to the addition through unconditioned spece are less than 40 linear ft. (2) Minimum efficiencies are those set by the National Appliance Energy Conservation Act of 1987 for typical residential equipment and are sled to NAECA rules and regulatpits. For other types of equipment see Tables C403 2 3 (1-11) of the Commercial Provisions of the Florida Building Code, Energy Conservation. (3) For elednc storage volumes< gallons, minimum UEF =0.9349-(0.0001' volume) . For electric storage volumes >55 gallons, minimum UEF =2.2418-(0,011 volume). (4) For natural ggas storage volumes s 55 gallons, minimum UEF = 0692 - (0.0013' volume) . For natural gas storage volumes> 55 gallons, minimum UEF = 0.8072 - (O. 003 - volume). (5) For electric lankless, min. UEF = 0.92. For natural gas tentless, min. UEF = 0.81. (6) Referenced UEFs shown are for medium draw pattern value provided by manufacturer. (continued) R-58 FLORIDA BUILDING CODE — ENERGY CONSERVATION, 7th EDITION (2020) APPENDIX RD — FORMS FORM 13402—continued MANDATORY REQUIREMENTS Component Section Summary of Requirements Check To be caulked, gasketed, weatherstdpped or otherwise sealed per Table R402.4.1.1. Recessed lighting IC-mted as having s 2.0 ctm Air leakage Rl tested to ASTM E283. Windows and tloors: 0.3 cfmisq.ft (swinging doors: 0.5 cim(s0 when tested to NFRC 400 or AAMA/WDMAICSA 101 A.S. 21A440. Fireplaces: Tight -filling flue dampers & outdoor combustion air Programmablethennostat R403,1.2 A programmable thermostat is required for the primary heating ar cooling system. Ducts shall be tested as per Section R403.3.2 by either Individuals Air distribution system R403.3.2 as named In Section 553.993(5) or (7), Florida StaNtas, or R403.3.4 individuals licensed as set forth in Section 489.105(3) (1), (g) or (i), Florida Statutes. Air handling units are not allowed in attics. Comply with efficiencies in Table C404.2. Hot water pipes insulated Water heaters R403.5 toz R-3 to kitchen outlets, other cases. Circulating systems to have an automatic or accessible manual OFF switch. Heat trap required for vertical pipe risers. Siang calculation performed & attached. Special occaeion cooling vx Coolinglheating equipment Rl or heating capacity requires separate system or variable capacity system. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except it Swimming pools&spas R403.10 70% of heat from site -recovered energy. OBitimer switch required. Gas heaters minimum thermal efficiency is 82%. Heat pump pool �' heaters minimum COP is 4.0. Not lass than 90% of the lamps in permanently installed luminaires Lighting equipment R404.1 shall have an efficacy of at least 45lumens-per-waftor shall utilize lamps with an efficacy of not less than 65 lumens -per -watt. ions covered by his form are I hereby r»alry, th�Idlngs Review of plans and specifications covered by this form Indicate In compliancewe, Energy C rv�t i({{ compliance with the Florida Building Code, Energy Conservation. Before PREPAREDDee (/7 eonetruction is complete, this building will be Inspected for compliance In I hereby certify thianceWflh lh9�J( ids uilding accordance with Section 553.908, F.S. Code. Energy Cance on.G OWNER/AGENT: 'V% CODE OFFICIAL: _ Date: Date: J O FLORIDA BUILDING CODE — ENERGY CONSERVATION, 7th EDITION (2020) R-59