Loading...
380 11th St RES22-0297 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: ALOE DANIEL 2354 GOLFVIEW DR PITTSBURGH PA 15241 COMPANY:ADDRESS:CITY:STATE:ZIP: Opus Group, Inc 1510 Montana Avenue JACKSONVILLE FL 32207 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 170090 0000 ATLANTIC BEACH JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 380 11TH ST RESIDENTIAL ALTERATION RESIDENTIAL INTERIOR RENOVATION $25000.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $180.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $90.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $4.05 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.70 TOTAL: $276.75 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 7/28/2023 PERMIT NUMBER RES22-0297 ISSUED: 7/28/2023 EXPIRES: 1/24/2024 RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 2 of 2Issued Date: 7/28/2023 PERMIT NUMBER RES22-0297 ISSUED: 7/28/2023 EXPIRES: 1/24/2024 RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION INTERIOR RENOVATION 380 11TH ST Opus Group, Inc RES22-0297 RES22-0297 EXISTING FLOOR / DEMOLITION PLAN SCALE: 1/4" = 1'-0" 10070 OHD W D 2668266826683068 3050 SH 3050 SH3030 SH3030 SH 2050 SH2050 SH3050 SH 3050 SH 2020 SH2020 SH3030 SH3030 SH2668286828682668 2668 2668 3068 TEMP 286830683068OHCRANGEDW 36" REF 30683068 FIXED2050 SH2050 SH R&SR&SR&S 3030 SH3030 SHR&SR&S2468 30"X60" TUB /SHOWER16070 SGD 2668 10 SL 5-SHHALLWAY HALLWAY ENTRY 3'-8"x9'-10"R&SBEDROOM #2 9'-11"X11'-8" BEDROOM #3 9'-10"X11'-8" DEN 9'-6"X10'-1" KITCHEN 18'-10"X14'-11" DINING 22'-6"X16'-10" MASTER BATH W.I.C. 5'-8"X14'-0"MASTER BEDROOM 16'-7"X14'-11" OFFICE 12'-0"X14'-0" LIVING ROOM 22'-6"X17'-5" BATH #2 8'-11"X6'-5" STEPSTEPRAILING RAILING SINK BENCH FIREPLACEBUILT-INBUILT-INBUILT-INSTEPS FRONT DOOR AND SECTION OF WALL TO BE REMOVED AND REPLACED WITH NEW DOOR AND SIDE LITE WINDOW TO BE REMOVED AND REPLACED REMOVE EXISTING KITCHEN CABINETS, APPLIANCES, FLOORING AND RELATED APPURTENANCES AS NEEDED FOR NEW CONSTRUCTION REMOVE EXISTING WALL REMOVE EXISTING COLUMNS, RAILING AND STEPS AS NEEDED FOR NEW CONSTRUCTION REMOVE EXISTING BUILT-IN AS NEEDED FOR NEW CONSTRUCTION REMOVE EXISTING DOOR AND TRIM AS NEEDED FOR NEW CONSTRUCTION REMOVE EXISITNG FIREPLACE, AND BUILT-INS AS NEEDED FOR NEW CONSTRUCTION REMOVE EXISTING FIXTURES, CABINET, AND RELATED APPURTENANCES AS NEEDED FOR NEW CONSTRUCTION REMOVE EXISTING DOOR AND TRIM AS NEEDED FOR NEW CONSTRUCTION REMOVE EXISTING WALL AS NEEDED FOR NEW CONSTRUCTION REMOVE SHELVING AND RELATED APPURTENANCES AS NEEDED FOR NEW CONSTRUCTION REMOVE EXISTING WALLS, FIXTURES, VANITIES, FLOORING TILE, SHELVING AND RELATED APPURTENANCES AS NEEDED FOR NEW CONSTRUCTION REMOVE EXISTING STEPS REMOVE EXISTING WALL AS NEEDED FOR NEW CONSTRUCTION 3068 STEP UP UP UPUPUPGARAGE 12'-0"X25'-10" FLOOR LEVEL IN EXISTING MASTER BATH TO BE LOWERED TO MATCH CURRENT MASTER BEDROOM LEVEL; SEE STRUCTURAL FOR DETAILS PROPOSED FLOOR PLAN SCALE: 1/4" = 1'-0" NOTES: 1.IF SHOWER HAS GLASS ENCLOSURE, SAFETY GLAZING REQUIRED PER FBC R-308.4.5. 2.PROVIDE TEMPERED GLASS AS REQUIRED. 3.CONTRACTOR MUST FIELD VERIFY EXISTING CONDITIONS AND ALL DIMENSIONS PRIOR TO CONSTRUCTION. 42" WALL WITH TRIM AND GLASS ABOVE 28 TEMP 3068 3050 SH 3050 SH3030 SH3030 SH 2050 SH2050 SH3050 SH 3050 SH 2020 SH2020 SH3030 SH3030 SH28682668 2668 2668 3068 TEMP 3068 28683068306830683068 FIXED2050 SH2050 SH R&S R&SR&S2668 16070 SGD 10 SL HALLWAY HALLWAY ENTRY 3'-8"x9'-10"R&SBEDROOM #2 9'-11"X11'-8" BEDROOM #3 12'-2"X11'-8" DEN 9'-6"X10'-1" DINING ROOM 18'-10"X14'-11" LIVING 22'-6"X16'-10" MASTER BATH W.I.C. 22'-7"X6'-5" MASTER BEDROOM 15'-0"X13'-6" LAUNDRY STORAGE 12'-0"X14'-0" KITCHEN 22'-6"X17'-5" GARAGE 12'-0"X25'-10" BATH #2 8'-11"X6'-5" STEP BENCH NEW FIREPLACE WITH TV ABOVE DW 42" VANITY 2'-9"OHCOHCOHCCONSTRUCT NEW WALL TO CLOSE IN DOORWAY (TYP.)STEPSR&S TP 84" VANITYW D 60" BASEOHC26685-SH SHOWER VALVES 18" DEEP BENCH2668FLOOR LEVEL IN EXISTING MASTER BATH TO BE LOWERED TO MATCH CURRENT MASTER BEDROOM LEVEL; SEE STRUCTURAL FOR DETAILSSINKOHC5'5'16 SL 2'-8"3'-6"2'-6"2'-6"4'-7 1/2"3'-2"3'-4"4'11'-2"2' 1'2'-4"4'-2 1/2"9'4'-2 1/2"2' 30" MW 18" TRASH / RECYCLE 30" COOKTOP / HOOD30" DOUBLEOVEN24" WINE REF 36" REF 24" ICE MAKER 4'-7 1/2"2668 UP 10070 OHD 286818" DEEP BENCH2668LINEN5-SHCONSTRUCT NEW WALL TO CLOSE IN WINDOW (TYP.) STEP UP UP3'-10"7'-1"3'-9"3'-10"7'-3" 15'-4" 4'18'-7" 2'-4"4'-11" 1'-6"6'-6"1'-6"2'-10"17'-5"6'-9"STEPS DN SHEET NUMBER SHEET NAME CODE INFORMATION BUILDING CODE: CONSTRUCTION TYPE: OCCUPANCY CLASS: DRAWING INDEX A1.1 A1.2 A3.1 FLOOR PLANS ELECTRIC PLAN DETAIL SHEET 2020 FLORIDA BUILDING CODE RESIDENTIAL 7TH ADDITION 2020 FLORIDA BUILDING CODE PLUMBING 2020 FLORIDA BUILDING CODE MECHANICAL 2017 NEC 5B R-3 CSSDateSheet Job Scale DateNo.RevisionsBy7654321DateByJWB CONSTRUCTION GROUP7563 Philips Highway, Suite 109Jacksonville, FL 32256(904) 677-6777Prepared For:Shields CAD Services243 Tarrasa Drive | Jacksonville, FL 32225Phone : (904) 241-1540Website: www.shieldscadservices.com | Email: billeshields@gmail.com©2022 Shields CAD Services LLCA1.1 ALOEALOE RESIDENCE REMODEL380 11TH STREET | ATLANTIC BEACH, FL 32233FLOOR PLANS10-27-22 AS SHOWN RES22-0297 Cover Page: 1. Contractor’s Business name, Certificate/License #, address, phone contact, email address. 2. Address of project 3. Occupancy Class: For One & Two Family Dwellings 4. Applicable Codes and their currently used editions; building, plumbing, electrical, mechanical, fire prevention and COAB Code of Ordinances. 5. Energy forms as required by the Florida Energy Code. 6. Index of all drawings & attachments and all pages numbered. 7. Dimensions of all new additions, or internal reconfigurations and their new dimensions. 8. Elevations of the building that shows the affected changes areas. 9. Printed name, contact info, date and signature of person responsible for the design of the structure. Revision Request/Correction to Comments **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED.City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT #: _____________________ Revision to Issued Permit OR Corrections to Comments Date: ________________ Project Address: ____________________________________________________________________________________ Contractor/Contact Name: ____________________________________________________________________________ Contact Phone: ______________________________ Email: _________________________________________________ Description of Proposed Revision / Corrections: __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ I_______________________________ affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) Will proposed revision/corrections add additional square footage to original submittal? No Yes (additional s.f. to be added: _____________________________) Will proposed revision/corrections add additional increase in building value to original submittal? No *Yes (additional increase in building value: $____________________) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: _______________________________________________________ __________________________________________________________________________________________________ (Office Use Only) Approved Denied Not Applicable to Department Permit Fee Due $_______________ Revision/Plan Review Comments_______________________________________________________________________ __________________________________________________________________________________________________ Department Review Required: Building _____________________________________________ Planning & Zoning Reviewed By Tree Administrator Public Works Public Utilities _____________________________________________ Public Safety Date Fire Services Updated 10/17/18 RES22-0297 CODE INFORMATION BUILDING CODE: CONSTRUCTION TYPE: OCCUPANCY CLASS: 2020 FLORIDA BUILDING CODE RESIDENTIAL 7TH ADDITION 2020 FLORIDA BUILDING CODE PLUMBING 2020 FLORIDA BUILDING CODE MECHANICAL 2017 NEC 5B R-3 CSSSheet Job Scale Date JWB CONSTRUCTION GROUP7563 Philips Highway, Suite 109Jacksonville, FL 32256(904) 677-6777Prepared For:Shields CAD Services243 Tarrasa Drive | Jacksonville, FL 32225Phone : (904) 241-1540Website: www.shieldscadservices.com | Email: billeshields@gmail.com©2023 Shields CAD Services LLCDateNo.RevisionsBy7654321THESE PLANS ARE THE PROPERTY OF SHIELDS CADSERVICES LLC AND ARE FOR SINGLE USE ONLY FORTHE SPECIFIED ADDRESS AND ARE NOT VALID UNLESSELECTRONICALLY SIGNED BY WILLIAM EDWARDSHIELDS, JR. PLANS WITHOUT AN ADDRESS ARE NOTFOR PERMITTING OR CONSTRUCTION. ANY COPIESMADE OF THESE PLANS WITHOUT THE SIGNERSCONSENT IS A VIOLATION OF COPYRIGHT LAW.ALOE 07-06-23 AS SHOWNALOE RESIDENCE REMODELFLOOR PLANSA1.0380 11TH STREET | ATLANTIC BEACH, FL 32233C:\Users\bille\OneDrive\1-Drawings\JWB Construction Group\~Custom Plans\380 11th Street AB Remodel\2023-07-06 380 11th Street AB Remodel.dwg, 7/10/2023 9:39:24 AM ALOE RESIDENCE REMODEL 380 11TH ST, ATLANTIC BEACH, FL 32233 AVANT CONSTRUCTIONLicense # CGC0605121510 Montana Ave. Jacksonville, FL 32207904-399-8846peter@avant-build.com Drawing IndexA1.0 Title PageA1.1 Existing Floor Plan/Demolition Plan and Proposed Floor Plan EXISTING FLOOR / DEMOLITION PLAN SCALE: 1/4" = 1'-0" 10070 OHD W D 2668266826683068 3050 SH 3050 SH3030 SH3030 SH 2050 SH2050 SH3050 SH 3050 SH 2020 SH2020 SH3030 SH3030 SH2668286828682668 2668 2668 3068 TEMP 286830683068OHCRANGEDW 36" REF 30683068 FIXED2050 SH2050 SH R&SR&SR&S 3030 SH3030 SHR&SR&S2468 30"X60" TUB /SHOWER16070 SGD 2668 10 SL 5-SHHALLWAY HALLWAY ENTRY 3'-8"x9'-10"R&SBEDROOM #2 9'-11"X11'-8" BEDROOM #3 9'-10"X11'-8" DEN 9'-6"X10'-1" KITCHEN 18'-10"X14'-11" DINING 22'-6"X16'-10" MASTER BATH W.I.C. 5'-8"X14'-0"MASTER BEDROOM 16'-7"X14'-11" OFFICE 12'-0"X14'-0" LIVING ROOM 22'-6"X17'-5" BATH #2 8'-11"X6'-5" STEPSTEPRAILING RAILING SINK BENCH FIREPLACEBUILT-INBUILT-INBUILT-INSTEPS FRONT DOOR AND SECTION OF WALL TO BE REMOVED AND REPLACED WITH NEW DOOR WINDOW TO BE REMOVED AND REPLACED RAILINGS TO BE REMOVED AND REPLACED REMOVE EXISTING BUILT-IN AS NEEDED FOR NEW CONSTRUCTION REMOVE EXISTING DOOR AND WALL AS NEEDED FOR 36" DOOR REMOVE EXISTING FIREPLACE, AND BUILT-INS AND LEAVE PEDESTAL REMOVE EXISTING FIXTURES, CABINET, AND RELATED APPURTENANCES AS NEEDED FOR NEW CONSTRUCTION REMOVE EXISTING WALL AS NEEDED FOR NEW CONSTRUCTION REMOVE SHELVING AND RELATED APPURTENANCES AS NEEDED FOR NEW CONSTRUCTIONREMOVE EXISTING WALL FOR NEW DOOR 3068 STEP UP UP UPUPUPGARAGE 12'-0"X25'-10" WINDOW TO BE REMOVED AND FILLED IN TO MATCH EXISTING WINDOW TO BE REMOVED AND FILLED IN TO MATCH EXISTING BENCH TO BE REMOVED REPLACE EXISTING FOGGED WINDOW WITH NEW MATCHING WINDOW REMOVE EXISTING CLOSET AND DOOR TO EXPAND SHOWER REMOVE RANGE FROM ISLAND MOVE EXISTING WATER AND DRYER CONNECTIONS REMOVE EXISTING CLOSET FOR NEW CABINET REMOVE EXISTING WALL AND DOOR REMOVE EXISTING DOOR REMOVE EXISTING WALL FOR NEW DOOR PROPOSED FLOOR PLAN SCALE: 1/4" = 1'-0" NOTES: 1. IF SHOWER HAS GLASS ENCLOSURE, SAFETY GLAZING REQUIRED PER FBC R-308.4.5. 2. PROVIDE TEMPERED GLASS AS REQUIRED. 3. CONTRACTOR MUST FIELD VERIFY EXISTING CONDITIONS AND ALL DIMENSIONS PRIOR TO CONSTRUCTION. 3068 3050 SH 3050 SH3030 SH2050 SH2050 SH3050 SH 3050 SH 3030 SH3030 SH28682668 2668 3068 TEMP 3068 28683068306830683068 FIXED2050 SH2050 SH R&SR&S16070 SGD 10 SL HALLWAY HALLWAY BEDROOM #2 9'-11"X11'-8" BEDROOM #3 12'-2"X11'-8" DEN 9'-6"X10'-1"GARAGE 12'-0"X25'-10" BATH #2 8'-11"X6'-5" CONSTRUCT NEW WALL TO CLOSE IN DOORWAY (TYP.)STEPS2668UP 10070 OHD 2868STEP UP 3838 SH DW KITCHEN 18'-10"X14'-11" SINK RANGE WITHHOOD ABOVE24" MWSTEPSTEP NEW RAILINGUP UPOHCOHC3030 SH3030 SHW 2468 2668 MASTER BEDROOM 22'-7"X14'-11" STEPS UPNEW TOWEL CABINET D OHC OFFICE 12'-0"X14'-0"3068EXISTING PEDESTALDINING 22'-6"X16'-10" LIVING ROOM 22'-6"X17'-5" MASTER BATH NEW ALCOVE IN SHOWER BARN DOOR 2668 2668 NEW RAILING LAUNDRY CODE INFORMATION BUILDING CODE: CONSTRUCTION TYPE: OCCUPANCY CLASS: 2020 FLORIDA BUILDING CODE RESIDENTIAL 7TH ADDITION 2020 FLORIDA BUILDING CODE PLUMBING 2020 FLORIDA BUILDING CODE MECHANICAL 2017 NEC 5B R-3 CSSSheet Job Scale Date JWB CONSTRUCTION GROUP7563 Philips Highway, Suite 109Jacksonville, FL 32256(904) 677-6777Prepared For:Shields CAD Services243 Tarrasa Drive | Jacksonville, FL 32225Phone : (904) 241-1540Website: www.shieldscadservices.com | Email: billeshields@gmail.com©2023 Shields CAD Services LLCDateNo.RevisionsBy7654321THESE PLANS ARE THE PROPERTY OF SHIELDS CADSERVICES LLC AND ARE FOR SINGLE USE ONLY FORTHE SPECIFIED ADDRESS AND ARE NOT VALID UNLESSELECTRONICALLY SIGNED BY WILLIAM EDWARDSHIELDS, JR. PLANS WITHOUT AN ADDRESS ARE NOTFOR PERMITTING OR CONSTRUCTION. ANY COPIESMADE OF THESE PLANS WITHOUT THE SIGNERSCONSENT IS A VIOLATION OF COPYRIGHT LAW.ALOE 07-06-23 AS SHOWNALOE RESIDENCE REMODELFLOOR PLANSA1.1380 11TH STREET | ATLANTIC BEACH, FL 32233C:\Users\bille\OneDrive\1-Drawings\JWB Construction Group\~Custom Plans\380 11th Street AB Remodel\2023-07-06 380 11th Street AB Remodel.dwg, 7/10/2023 9:39:24 AM CONSTRUCT NEW WALL TO CLOSE IN DOORWAY (TYP.)