Loading...
1839 Taylor Way RERF23-0119 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: OVERSTREET DOLLENE LYNETTE 1839 TAYLOR WAY ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: UNIVERSAL ROOF AND CONTRACTING 5655 Carder Rd Orlando FL 32810 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 172282 1050 HUANG VILLAS CONDOMINIUM JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1839 TAYLOR WAY REROOF SHINGLE SHINGLE ROOF $7063.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved.\r\r b. All roofing projects require an In-Progress Inspection.\r\r c. Sheathing installation and replacement guidelines per APA.\r\r d. Underlayment must conform to FBC-R Table 905.1.1\r\r e. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 8/1/2023 PERMIT NUMBER RERF23-0119 ISSUED: 8/1/2023 EXPIRES: 1/28/2024 REROOF SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $90.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $94.00 2 of 2Issued Date: 8/1/2023 PERMIT NUMBER RERF23-0119 ISSUED: 8/1/2023 EXPIRES: 1/28/2024 REROOF SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION SHINGLE ROOF 1839 TAYLOR WAY UNIVERSAL ROOF AND CONTRACTING RERF23-0119 RERF23-0119 RERF23-0119 RERF23-0119 4/24/23, 3:57 PM Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtBNbEY5V%2boQT%2b6w7ahRegICQ8ucR6ixEAp7tx5AxBxAA%3d%3d 1/2 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL10674-R18 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419) 376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Robert J.M. Nieminen Florida License PE-59166 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 01/01/2099 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL10674_R18_COI_2023_01_COI_NIEMINEN.pdf Referenced Standard and Year (of Standard)Standard Year ASTM D1970 2015 ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2019 Equivalence of Product Standards Certified By RERF23-0119 4/24/23, 3:57 PM Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtBNbEY5V%2boQT%2b6w7ahRegICQ8ucR6ixEAp7tx5AxBxAA%3d%3d 2/2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/06/2023 Date Validated 02/09/2023 Date Pending FBC Approval 02/13/2023 Date Approved 04/11/2023 Summary of Products FL #Model, Number or Name Description 10674.1 Owens Corning Asphalt Roofing Shingles and Starters 3-tab, 4-tab, laminated, starter and hip & ridge shingles Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to ER, Section 5. Installation Instructions FL10674_R18_II_2022_02_03_FINAL_ER_OC_ASPHALT SHINGLES_FL10674-R18.pdf Verified By: Robert J. M. Nieminen PE - 59166 Created by Independent Third Party: Yes Evaluation Reports FL10674_R18_AE_2022_02_03_FINAL_ER_OC_ASPHALT SHINGLES_FL10674-R18.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: NEMO|etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT BY FLORIDA P.E. Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 Evaluation Report O37940.02.12-R13 FL10674-R18 Date of Issuance: 02/06/2012 Revision 13: 02/03/2023 SCOPE: This Evaluation Report is issued under F.A.C. Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles for use in FBC NON-HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluati on Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words “NEMO P.E. Evaluated” may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors a nd shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018 NEMO ETC, LLC Digitally signed by Robert Nieminen Date: 2023.02.03 '16:01:23 -05'00 RERF23-0119 NEMO|etc. NEMO ETC, LLC Evaluation Report O37940.02.12-R13 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL10674-R18 Owens Corning Asphalt Roof Shingles Revision 13: 02/03/2023 BACK TO TOP Page 2 of 10 ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Product Approval Method: Method 1, Option D – Codified Material, Evaluation by Engineer Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations of Use set forth herein. 2. STANDARDS: SECTION PROPERTY STANDARD YEAR 1507.2.4, R905.2.3 Physical Properties ASTM D1970 2015 1507.2.5, R905.2.4 Material standard ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2019 3. REFERENCES: ENTITY EXAMINATION REFERENCE DATE Owens Corning Equivalency Declaration 08/06/2019 PRI (CER12639) Various Certifications Various Certifications Current PRI (TST5878) ASTM D1970 OCF-382-02-01 10/24/2017 PRI (TST5878) ASTM D3161 OCF-459-02-01 08/16/2019 PRI (QUA9110) Quality Control Service Confirmation 04/05/2020 PRI (QUA9110) Quality Control Florida BCIS Current 4. PRODUCT DESCRIPTION: TABLE 1: ASPHALT SHINGLE COMPONENTS TYPE PRODUCT PLANT(S) MATERIAL STANDARD DESCRIPTION ACCESSORY STARTER STRIPS Starter Strip Shingle Houston, TX, Portland, OR ASTM D3462 starter strips for asphalt roof shingles Starter Strip Plus Medina, OH; Minneapolis, MN; Portland, OR SRS TopShield Starter Medina, OH; Minneapolis, MN; Portland, OR Starter Shingle Roll Brentwood, NH ASTM D1970 mineral-surfaced, fiberglass- reinforced, self-adhering SBS modified bitumen starter ASPHALT SHINGLES Supreme® Refer to PRI Certification ASTM D3462 fiberglass reinforced 3-tab asphalt roof shingles Berkshire® Refer to PRI Certification ASTM D3462 fiberglass reinforced, 4-tab asphalt roof shingles Duration® Premium Refer to PRI Certification ASTM D3462 fiberglass reinforced, laminated asphalt roof shingles Duration® Premium COOL Compton, CA Oakridge® Refer to PRI Certification TruDefinition® Duration® Refer to PRI Certification ASTM D3462 fiberglass reinforced, laminated asphalt roof shingles TruDefinition® Duration® Designer Color Collection Refer to PRI Certification TruDefinition® Duration STORM® Refer to PRI Certification TruDefinition® Oakridge® Refer to PRI Certification NEMO|etc. NEMO ETC, LLC Evaluation Report O37940.02.12-R13 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL10674-R18 Owens Corning Asphalt Roof Shingles Revision 13: 02/03/2023 BACK TO TOP Page 3 of 10 TABLE 1: ASPHALT SHINGLE COMPONENTS TYPE PRODUCT PLANT(S) MATERIAL STANDARD DESCRIPTION HIP AND RIDGE SHINGLES Berkshire® Hip and Ridge Shingles with Sealant Refer to PRI Certification ASTM D3462 fiberglass reinforced, hip and ridge asphalt roof shingles DuraRidge® Hip and Ridge Shingles with Sealant Refer to PRI Certification ProEdge® Refer to PRI Certification 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions, as defined in FBC Chapter 2 (i.e., Broward and Miami-Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classificat ion. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications TABLE 2A: WIND CLASSIFICATIONS, ASPHALT SHINGLES PRODUCT FBC TABLE 1507.2.7.1 OR R905.2.6.1 Supreme® ASTM D3161, Class F and ASTM D7158, Class H Berkshire® Duration® Premium Duration® Premium COOL TruDefinition® Duration® TruDefinition® Duration® Designer Color Collection TruDefinition® Duration STORM® Oakridge® TruDefinition® Oakridge® 5.5.1 Classification by ASTM D7158: ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. TABLE 2B: WIND CLASSIFICATIONS, STARTER STRIPS AND HIP & RIDGE TYPE PRODUCT FBC TABLE 1507.2.7.1 OR R905.2.6.1 Starter Strips Starter Strip Shingle ASTM D3161, Class F Starter Strip Plus SRS TopShield Starter Hip & Ridge Shingles Berkshire® Hip and Ridge Shingles with Sealant ASTM D3161, Class F DuraRidge® Hip and Ridge Shingles with Sealant ProEdge® 5.5.2 Refer to Owens Corning published information on wind resistance and installation limitations. NEMO|etc. NEMO ETC, LLC Evaluation Report O37940.02.12-R13 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL10674-R18 Owens Corning Asphalt Roof Shingles Revision 13: 02/03/2023 BACK TO TOP Page 4 of 10 5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. 6. INSTALLATION: 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer’s minimum requirements. 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufacturer’s published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and published installation instructions. 6.2 ACCESSORY STARTERS: 6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens Corning current published instructions, using minimum five (5) nails per strip. Figure 1: Minimum Nailing, Starter Strip Figure 2: Minimum Nailing, Starter Strip Plus NEMO|etc. NEMO ETC, LLC Evaluation Report O37940.02.12-R13 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL10674-R18 Owens Corning Asphalt Roof Shingles Revision 13: 02/03/2023 BACK TO TOP Page 5 of 10 6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions. Figure 3: Starter Shingle Roll 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire® shingles require minimum five (5) nails per shingle. Special methods of fastening are required when the roof slope exceeds 21 units vertical in 12 units horizontal. Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Supreme: Figure 4: Minimum Nailing, Supreme (Standard Size) Figure 5: Minimum Nailing, Supreme (Metric Size) NEMO|etc. NEMO ETC, LLC Evaluation Report O37940.02.12-R13 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL10674-R18 Owens Corning Asphalt Roof Shingles Revision 13: 02/03/2023 BACK TO TOP Page 6 of 10 6.3.1.2 Berkshire®: Figure 6: 5-Nail Pattern, Berkshire Figure 7: 6-Nail Pattern, Berkshire Figure 8: Mansard or Steep Slope Pattern, Berkshire NEMO|etc. NEMO ETC, LLC Evaluation Report O37940.02.12-R13 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL10674-R18 Owens Corning Asphalt Roof Shingles Revision 13: 02/03/2023 BACK TO TOP Page 7 of 10 6.3.1.3 Duration® Premium, Duration® Premium COOL, TruDefinition® Duration, TruDefinition® Duration® Designer Color Collection and TruDefinition® Duration STORM®: Figure 9: Standard 4-Nail Pattern, Duration Figure 10: 6-Nail Pattern, Duration Figure 11: Mansard or Steep Slope Pattern, Duration NEMO|etc. NEMO ETC, LLC Evaluation Report O37940.02.12-R13 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL10674-R18 Owens Corning Asphalt Roof Shingles Revision 13: 02/03/2023 BACK TO TOP Page 8 of 10 6.3.1.4 Oakridge® and TruDefinition® Oakridge®: Figure 12: Standard 4-Nail Pattern, Oakridge Figure 13: 6-Nail Pattern, Oakridge Figure 14: Mansard or Steep-Slope Pattern, Oakridge NEMO|etc. NEMO ETC, LLC Evaluation Report O37940.02.12-R13 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL10674-R18 Owens Corning Asphalt Roof Shingles Revision 13: 02/03/2023 BACK TO TOP Page 9 of 10 6.4 HIP AND RIDGE SHINGLES: 6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions. ➢ Berkshire® Hip and Ridge Shingles with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant require minimum two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations. 6.4.1.1 Berkshire® Hip and Ridge with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant: Figure 15: Isometric View, Berkshire and DuraRidge Figure 16: Plan View, Berkshire and DuraRidge 6.4.1.2 ProEdge®: Figure 17: Isometric View, ProEdge Figure 18: Plan View, ProEdge NEMO|etc. NEMO ETC, LLC Evaluation Report O37940.02.12-R13 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL10674-R18 Owens Corning Asphalt Roof Shingles Revision 13: 02/03/2023 BACK TO TOP Page 10 of 10 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies, LLC– QUA9110 ; (813) 621-5777; bwilson@pricmt.com - END OF EVALUATION REPORT - 6/19/23, 3:48 PM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv3yVVKJZ1QRAdhyI2u8kQGT5rnCzivlGUWauXGz5lk%2fQ%3d%3d 1/2 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL15216-R11 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Owens Corning Roofing and Asphalt, LLC Address/Phone/Email One Owens Corning Parkway Toledo, OH 43645 (740) 321-6345 Greg.Keeler@owenscorning.com Authorized Signature Keeler Greg Greg.Keeler@owenscorning.com Technical Representative Greg Keeler Address/Phone/Email 2790 Columbus Road Granville, OH 43023 (740) 321-6345 greg.keeler@owenscorning.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Robert Nieminen Florida License PE-59166 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 12/31/2023 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL15216_R11_COI_2022_01_COI_NIEMINEN.pdf Referenced Standard and Year (of Standard)Standard Year ASTM D226 (physicals)2009 ASTM D4533 (tear strength)2015 ASTM D4798 (weathering)2011 ASTM D4869 (liquid transmission)2016 ASTM D5035 (tensile strength)2011 Equivalence of Product Standards Certified By RERF23-0119 6/19/23, 3:48 PM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv3yVVKJZ1QRAdhyI2u8kQGT5rnCzivlGUWauXGz5lk%2fQ%3d%3d 2/2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/24/2022 Date Validated 10/25/2022 Date Pending FBC Approval 10/27/2022 Date Approved 12/13/2022 Date Revised 04/23/2023 Summary of Products FL #Model, Number or Name Description 15216.1 RhinoRoof U10, RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments Synthetic roof underlayments Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See ER Section 5 for Limits of Use. Installation Instructions FL15216_R11_II_2022_10_19_FINAL_ER_OC_RHINOROOF_FL15216- R11.pdf Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL15216_R11_AE_2022_10_19_FINAL_ER_OC_RHINOROOF_FL15216- R11.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: NEMO|etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT BY FLORIDA P.E. Owens Corning Roofing and Asphalt, LLC One Owens Corning Parkway Toledo, OH 43659 (740) 321-6345 Evaluation Report I40510.02.12-R12 FL15216-R11 Date of Issuance: 02/17/2012 Revision 12: 10/19/2022 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: RhinoRoof U10, RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluati on Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words “NEMO P.E. Evaluated” may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors a nd shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4. Prepared by: CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEMO ETC, LLC Digitally signed by Robert Nieminen Date: 2022.10.19 '11:06:26 -04'00 RERF23-0119 NEMO|etc. ©NEMO ETC, LLC Evaluation Report I40510.02.12-R12 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ AND HVHZ EVALUATION (Method 1D) FL15216-R11 RhinoRoof U10, RhinoRoof U20, ABC Pro Guard 20 Revision 12: 10/19/2022 and SRS TopShield TS20 Roof Underlayments Page 2 of 4 ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Product Approval Method: Method 1, Option D – Codified Material, Evaluation by Engineer Compliance Statement: RhinoRoof U10, RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments, as produced by Owens Corning Roofing and Asphalt, LLC, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with applicable sections of the following Standards. Compliance is subject to the Installation Requirements and Limitations of Use set forth herein. 2. STANDARDS: SECTION PROPERTIES STANDARD YEAR 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) Tear strength ASTM D4533 2015 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) Tensile strength ASTM D5035 2011 1507.1.1.1(5) / R905.1.1.1(5) Liquid water transmission ASTM D4869 2016 1518.4, RAS 115 Unrolling, Breaking Strength, Pliability ASTM D226 2009 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: ENTITY EXAMINATION REFERENCE DATE PRI (TST5878) ASTM D226 / D4798 / D4869 OCF-394-02-07.4 01/06/2020 PRI (TST5878) ASTM D226 / D4798 OCF-464-02-02.2 01/06/2020 PRI (TST5878) ASTM D4533 / D5035 / D4798 1378T0109 10/15/2020 PRI (TST5878) ASTM D4533 / D5035 1378T0127 10/15/2020 PRI (TST5878) ASTM D8257-20 1378T0138 02/25/2021 PRI (TST5878) ASTM D8257-20 1378T0139 03/23/2021 PRI (TST5878) ASTM D8257-20 1378T0141 05/18/2021 ITS (QUA1673) ITS Audit Manual 3144566COQ-006A 09/10/2020 ITS (QUA1673) Quality Control Service Confirmation 08/13/2021 ITS (QUA1673) Quality Control Florida BCIS Current 4. PRODUCT DESCRIPTION: TABLE 1: EVALUATED UNDERLAYMENTS PRODUCT SPECIFICATION PLANT(S) DESCRIPTION RhinoRoof U10 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) Qingdao, China Multilayered polymer woven coated synthetic roof underlayment RhinoRoof U20 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) Qingdao, China Silvassa, India Multilayered polymer woven coated synthetic roof underlayment ABC Pro Guard 20 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) Silvassa, India Multilayered polymer woven coated synthetic roof underlayment SRS TopShield TS20 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) Silvassa, India Multilayered polymer woven coated synthetic roof underlayment NEMO|etc. ©NEMO ETC, LLC Evaluation Report I40510.02.12-R12 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ AND HVHZ EVALUATION (Method 1D) FL15216-R11 RhinoRoof U10, RhinoRoof U20, ABC Pro Guard 20 Revision 12: 10/19/2022 and SRS TopShield TS20 Roof Underlayments Page 3 of 4 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.3 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 or FBC HVHZ 1516 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.4 RhinoRoof U10, RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable roof covers: TABLE 2: ROOF COVER OPTIONS FBC SECTION: 1507.2 1507.3 1507.4 & 1507.5 1507.7 1507.8 & 1507.9 FBC HVHZ SECTION: TAS 110(S10), RAS 115 TAS 110(S11), RAS 118, 119 & 120 RAS 133 TAS 110(S11) RAS 130 UNDERLAYMENT ASPHALT SHINGLES ROOF TILE METAL SLATE OR SLATE-TYPE SHINGLES WOOD RhinoRoof U10 Yes No Yes No NON-HVHZ: No HVHZ: Yes RhinoRoof U20 Yes No Yes No NON-HVHZ: No HVHZ: Yes ABC Pro Guard 20 Yes No Yes No NON-HVHZ: No HVHZ: Yes SRS TopShield TS20 Yes No Yes No NON-HVHZ: No HVHZ: Yes 5.6 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS UNDERLAYMENT MAXIMUM EXPOSURE (DAYS) RhinoRoof U10 90 RhinoRoof U20 90 ABC Pro Guard 20 90 SRS TopShield TS20 90 NEMO|etc. ©NEMO ETC, LLC Evaluation Report I40510.02.12-R12 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ AND HVHZ EVALUATION (Method 1D) FL15216-R11 RhinoRoof U10, RhinoRoof U20, ABC Pro Guard 20 Revision 12: 10/19/2022 and SRS TopShield TS20 Roof Underlayments Page 4 of 4 6. INSTALLATION: 6.1 RhinoRoof U10, RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments shall be installed in accordance with the manufacturer’s published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. 6.3 RhinoRoof U10, RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments: 6.3.1 NON-HVHZ Jurisdictions: 6.3.1.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception), 1507.1.1.1(3, Exception) or 1507.1.1.1(5) or FBC Residential R905.1.1.1(2, Exception), R905.1.1.1(3, Exception) or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer’s installation instructions. FBC requirements take precedence over the manufacturer’s installation instructions. 6.3.1.2 Fasteners: Minimum fasteners shall be corrosion resistant, ring-shank cap nails shall be as set forth in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3. 6.3.2 HVHZ Jurisdictions: 6.3.2.1 Shall be installed in a shingle fashion with minimum 4-inch wide side (horizontal) laps and minimum 6-inch wide end laps, and fastened in accordance with FBC HVHZ 1518.2 : • grid pattern of 12 inches between the overlaps, with 6-inch spacing at the overlaps 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY ASSURANCE ENTITY: Intertek Testing Services NA Inc. – QUA1673; (312) 906-7779; maura.norlander@intertek.com - END OF EVALUATION REPORT - 1/15/2021 Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv1dAvIteOYO%2bC3zFtrydq9fPhgLACiVmFHfXqoD3ASJQ%3d%3d 1/2 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL10758-R8 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Greg Keeler Address/Phone/Email 2790 Columbus Road Granville, OH 43023 (740) 321-6345 greg.keeler@owenscorning.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Zachary R. Priest Florida License PE-74021 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 12/31/2024 Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL10758_R8_COI_OCR14003.4 2020 FBC Eval Vents final_.pdf Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code 1708.2 RERF23-0119 1/15/2021 Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv1dAvIteOYO%2bC3zFtrydq9fPhgLACiVmFHfXqoD3ASJQ%3d%3d 2/2 Product Approval Method Method 2 Option B Date Submitted 08/10/2020 Date Validated 12/16/2020 Date Pending FBC Approval 09/18/2020 Date Approved 12/17/2020 Summary of Products FL #Model, Number or Name Description 10758.1 VentSure 4-Foot Strip Heat and Moisture Ridge Vents Copolymer plastic low profile attic ridge vents for installation in shingle roof systems Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to evaluation report Installation Instructions FL10758_R8_II_OCR14003.4 2020 FBC Eval Vents final_.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL10758_R8_AE_OCR14003.4 2020 FBC Eval Vents final_.pdf Created by Independent Third Party: Yes 10758.2 VentSure Low Profile Slant Back Roof Vent With Exterior Louver Galvanized metal roof vent Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to evaluation report. Installation Instructions FL10758_R8_II_OCR14003.4 2020 FBC Eval Vents final_.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL10758_R8_AE_OCR14003.4 2020 FBC Eval Vents final_.pdf Created by Independent Third Party: Yes 10758.3 VentSure Rigid Roll Ridge Vent Ridge Ventilation System Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to evaluation report. Installation Instructions FL10758_R8_II_OCR14003.4 2020 FBC Eval Vents final_.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL10758_R8_AE_OCR14003.4 2020 FBC Eval Vents final_.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: