890 Begonia St ERES23-0177 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP:
ARVIN KEVIN ET AL 890 BEGONIA ST ATLANTIC BEACH FL 32233-5946
COMPANY:ADDRESS:CITY:STATE:ZIP:
WEST COAST ELECTRICAL
& LIGHTING 5871 COUNTRY LAKES DR FT MYERS FL 33905
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
170926 9900 ATLANTIC BEACH SEC H
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
890 BEGONIA ST ELECTRICAL RESIDENTIAL 40 amp BREAKER FOR EV
CHARGER $1320.00
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
ELEC REPAIRS AND MISC 455-0000-322-1000 0 $35.00
ELECTRICAL BASE FEE 455-0000-322-1000 0 $55.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL: $94.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 8/2/2023
PERMIT NUMBER
ERES23-0177
ISSUED: 8/2/2023
EXPIRES: 1/29/2024
ELECTRICAL RESIDENTIAL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
2 of 2Issued Date: 8/2/2023
PERMIT NUMBER
ERES23-0177
ISSUED: 8/2/2023
EXPIRES: 1/29/2024
ELECTRICAL RESIDENTIAL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
ERES23-0177
Site Layout (Riser)
200A Electrical
Panel
Resident:
Kevin Arvin
890 Begonia St
Atlantic Beach, FL 32233
Electrical Contractor:
West Coast Electrical & Lighting Services
5871 Country Lakes Dr
Fort Myers, FL 33905
Description:
Install 40A breaker and NEMA 14-50 outlet for
EV charger.
EV Outlet
NEMA 14-50
<30’
40A GFCI
Breaker
If within 20ft of the panel – #6 THHN GFCI
#8 THHN 2p
If it is through the attic – 6/3 Romex
Location of outlet/charger – within the garage
ERES23-0177
Customer:Kevin Arvin
Address:890 Begonia St Atlantic Beach, FL 32233
General Lighting and Receptacle Load Watts Total
1700 Square Footage of House 3 Watts/sq ft 5100
Kitchen Circuits
2 Small Appliance Circuit Min 2 1,500 3000
Electric Oven 2,000 0
Electric Cook Top 5,000 0
1 Range 7,500 7500
Gas Range 150 0
1 Microwave 1,500 1500
1 Garbage Disposal / Dishwasher 1,100 1100
Laundry Circuit
1 Laundry Circuit 1,500 1500
1 Electric Dryer 5,000 5000
Gas Dryer 150 0
Other Electrical Loads
1 Electric Water Heater 4,500 4500
Electric Tankless Water Heater 13,500 0
Gas Water Heater 150 0
Gas Tankless Water Heater 150 0
First 10,000 @ 100%10,000
Remainder at 40%11,680
Swimming Pool / Spa
1 Pool Pump's 1,500 1500
Pool Electric Heater 11,000 0
Hot Tub / Spa 5,000 0
Heating and Air Conditioning (Heat Strip 220.82 C 65%)
1 Use Largest AC VA = 4,140 Heat Load VA = 10,000 6,500 6500
Use Largest AC VA = 4,140 Heat Load VA = 10,000 6,500 0
Use Largest AC VA = 4,140 Gas Heat Load VA = 530 4,140 0
1 Electric Vehicle Charger 7,360 7360
37,040
Total Calculated Load Amps 154
Level 2 Electric Vehicle Charger - Service Load Calculator
2017 NFPA 70 Optional Calculation - Single Family
West Coast Electrical & Lighting Services
Phone 239-690-2852 / Lic# EC13004842
ERES23-0177
Existing Panel Rating Amps 200