Loading...
1945 BEACH AVE - RESO22-0053 ENGINEERING LETTER CHRISTOPHER C. KATHE, INC. CONSULTING STRUCTURAL ENGINEERS 904 161"AVENUE NORTH JACKSONVILLE BEACH, FLORIDA 32250 Office(808)217-4707 FL P.E.No. 36820 HI S.E. No. 11911 August 07, 2023 Carlton Construction, Inc. Suite 1 4615 US Highway 17 Flemming Island, Florida 32003 Attn: Rusty White Re: "Break-Away" Retaining Wall Foundation 1945 Beach Avenue Atlantic Beach, Florida Job No.: E23-018 Rusty, The contractor may install the "Break-Away" 12"deep x 28"wide retaining wall concrete foundation independent in lieu of the combined monolithic slab and foundation indicated on Section 2/S-3, structural sheet S-3, dated 06/19/2023. The original structural analysis of the retaining wall utilized an independent foundation. The monolithic slab and foundation rationale was originally developed to minimize the number of concrete pump set-ups and concrete pours. The contractor may butt the adjoining monolithic slab into the side face of the 12"deep x 28" wide retaining wall concrete foundation OR the contractor may install the adjoining monolithic slab directly on top of the 12"deep x 28" wide retaining wall concrete foundation. All specified foundation reinforcing shall remain as originally designed. Sincerely, Christopher C. Kathe, P.E., S.E. DO /fl1 1 Z P Z3 CHRISTOPHER C Digitally signed by CHRISTOPHER C KATHE KATHE Date:2023.08.07 12:20:12-0400'