Loading...
1565 SELVA MARINA DR ERES23-0173 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: BROOKS T DANIEL 12931 PLANTERS CREEK CIR S JACKSONVILLE FL 32224 COMPANY:ADDRESS:CITY:STATE:ZIP: AMERICAN ELECTRICAL CONTRACTOR 9016 Philips Hwy JACKSONVILLE FL 32256 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 171945 0000 SELVA MARINA UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1565 SELVA MARINA DR ELECTRICAL RESIDENTIAL Service upgrade 400 amps and Generator 24 KW $20000.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT ELEC REPAIRS AND MISC 455-0000-322-1000 0 $35.00 ELEC SERVICE CHANGE 455-0000-322-1000 400 $130.00 ELECTRICAL BASE FEE 455-0000-322-1000 0 $55.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.30 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.20 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 8/17/2023 PERMIT NUMBER ERES23-0173 ISSUED: 8/17/2023 EXPIRES: 2/13/2024 ELECTRICAL RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 TOTAL: $225.50 2 of 2Issued Date: 8/17/2023 PERMIT NUMBER ERES23-0173 ISSUED: 8/17/2023 EXPIRES: 2/13/2024 ELECTRICAL RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 ERES23-0173 JOB COPY DESCRIPTION ACCOUNT QTY PAID PermitTRAK $225.50 ERES23-0173 Address: 1565 SELVA MARINA DR APN: 171945 0000 $225.50 ELECTRICAL $220.00 ELECTRICAL BASE FEE 455-0000-322-1000 0 $55.00 ELEC REPAIRS AND MISC 455-0000-322-1000 0 $35.00 ELEC SERVICE CHANGE 455-0000-322-1000 400 $130.00 STATE SURCHARGES $5.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.30 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.20 TOTAL FEES PAID BY RECEIPT: R24325 $225.50 Printed: Thursday, August 17, 2023 2:18 PM Date Paid: Thursday, August 17, 2023 Paid By: AMERICAN ELECTRICAL CONTRACTOR Pay Method: CREDIT CARD 1140957427 1 of 1 Cashier: TG Cash Register Receipt City of Atlantic Beach Receipt Number R24325 ERES23-0173 By vangers at 12:53 pm, Aug 10, 2023 7"PALM9"HOLLY12"ELM11"PALM14"OAK24"MAG3"ORANGE10" ELM25"OAK48"OAK18"PALM26" OAKSAMPLE12347.5' BRL7.5' BRL SHERRY DRIVE - COUNTY ROAD NO. 551 (PLAT0CONCRETE DRIVEMETERWATER40' BUILDING RESTRICTION LINE (P)LOT 8S12°22'26"E 115.00' (FM)ENTRYCONC.COVERED6' P.V.C. FENCE6' WOOD FENCE4' CHAIN LINK FENCEA/CCONCRETE WALKASPHALT SURFACE WITH CURB & GUTTERA 100' WIDE RIGHT OF WAYS E L V A M A R I N A D R I V ELOT 12LOT 10S11°56'50"E 115.00' (PLAT)S78°03'10"W 175.00' (PLAT)S11°56'50"E 115.00' (PLAT)N78°03'10"E 175.00' (PLAT)S12°22'26"E 115.00' (FM)S77°37'34"W 175.00' (FM)N77°37'34"E 175.00' (FM)F.F.E. 16.5SUBPANEL123123EXST'GOPENPATIO13.38'POOL20'-0" SETBACK PER SURVEYTO BE VERIFIED BY JD12.0'1'-6"6' WOOD FENCE5'-0"SIDESETBACK101010109.89.91010.510 9.5top decking9.5109.810101010.010.5109.9AVG 9.97'35'-2"34'-4"12'-0"12.0'12.0'EXISTING 1-STORY RESIDENCE(NO WORK)CALCULATEDAVERAGE GRADEDETACHEDACCESSORYGUEST HOUSE12.38' top of floor24"MAG3"ORANGE10" ELM25"OAK48"OAK18"PALM26" OAK1512347.5' BRL7.5' BRL11111111131412111210141414131313121111119991010101010101012121212LOT 86' P.V.C. FENCE6' WOOD FENCE4' CHAIN LINK FENCELOT 12LOT 10S11°56'50"E 115.00' (PLAT)S78°03'10"W 175.00' (PLAT)N78°03'10"E 175.00' (PLAT)S12°22'26"E 115.00' (FM)S77°37'34"W 175.00' (FM)N77°37'34"E 175.00' (FM)F.F.E. 16.5SUBPANEL123123EXST'GOPENPATIO13.38'POOL20'-0" SETBACK PER SURVEYTO BE VERIFIED BY JD12.0'1'-6"6' WOOD FENCE5'-0"SIDESETBACK101010109.89.91010.510 9.5top decking109.5109.810101010.010.5109.9AVG 9.97'35'-2"34'-4"12'-0"12.0'12.0'EXISTING 1-STORY RESIDENCE(NO WORK)CALCULATEDAVERAGE GRADEDETACHEDACCESSORYGUEST HOUSE12.38' top of floorNorth /Elev KeyBROOKS RESIDENCE ADDITION1565 SELVA MARINE DR, ATLANTIC BEACH, FLARCHITECT, INC.John H. DoddFL:AR00168672775 RACHEAL AVENUEFERNANDINA BEACH, FL 32034TEL (904) 583-4044johndoddarchitect@gmail.comNWESRevisions after Signed ReleaseShts. MarkedNature ofRevisions:No.Date:PERMIT: 5-10-23STATEOFFLORID A REGISTEREDARCHITECTAR0016867JOHNHOWELLDODD This item has been electronically signedand sealed by John H. Dodd, ArchitectAR0016867 on the Date and/or TimeStamp shown using a digital signature.Printed copies of this document are notconsidered signed and sealed and thesignature must be verified on anyelectronic copies.SheetDigitalSealSITE PLANA-0SITE PLAN18"=1'18 " = 1 ' - 0 "086 10 15 2042535304540502SCALEGRAPHICNorth /Elev KeyBROOKS RESIDENCE ADDITION1565 SELVA MARINE DR, ATLANTIC BEACH, FLARCHITECT, INC.John H. DoddFL:AR00168672775 RACHEAL AVENUEFERNANDINA BEACH, FL 32034TEL (904) 583-4044johndoddarchitect@gmail.comNWESRevisions after Signed ReleaseShts. MarkedNature ofRevisions:No.Date:PERMIT: 5-10-23STATEOFFLORID A REGISTEREDARCHITECTAR0016867JOHNHOWELLDODD This item has been electronically signedand sealed by John H. Dodd, ArchitectAR0016867 on the Date and/or TimeStamp shown using a digital signature.Printed copies of this document are notconsidered signed and sealed and thesignature must be verified on anyelectronic copies.SheetDigitalSeal18 " = 1 ' - 0 "086 10 15 2042535304540502SCALEGRAPHICWITH EXISTINGCONTOURSSITE PLAN18"=1'ZONING RS-L RESIDENTIAL, SINGLE-FAMILY, LARGE LOTS- CODES: FLORIDA BUILDING CODE, 2020 (SEVENTH EDITION) RISK CATEGORY 2 BUILDING ASCE/SEI 7-16 "MINIMUM DESIGN LOADS FOR BUILDINGS"ELECTRIC CODE: NATIONAL ELECTRIC CODE 2017 FLOOD ZONE (AS REQU'D): ASCE 24- 14 FLOOD RESISTANT DESIGN AND CONSTRUCTION- DRAWINGS: THESE DRAWINGS PROVIDE THE INTENT AND GENERAL DESCRIPTION OF THE WORK. THE CONTRACTOR SHALL PROVIDE NECESSARY MATERIALS AND WORK FOR A COMPLETELY FINISHED PROJECT.CONSULT WITH THE OWNER IN THE EVENT OF DISCREPANCY OR UNCERTAINTY TO CLARIFY SCOPE OF WORK PRIOR TO BID.- DEVIATIONS FROM DRAWINGS: ARCHITECT DOES NOT ASSUME RESPONSIBILITY FOR OMISSIONS, UNWORKMAN-LIKE PERFORMANCE OR DEVIATIONS FROM THE PLANS, SPECIFICATIONS AND DETAILS WHICH MAYOCCUR BY CONTRACTOR OR CONTRACTORS DURING THE COURSE OF CONSTRUCTION. DEVIATIONS FROM DRAWINGS ARE AT CONTRACTOR(S) RISK UNLESS APPROVED IN WRITING OR WITH SEALEDSUPPLEMENTARY DRAWINGS OR SEALED CORRESPONDENCE FROM THE ARCHITECT.- CONTRACTOR'S & OWNER'S PERMIT DOCUMENT NOTE: THESE DRAWINGS ARE TO BE CONSIDERED A "CONTRACTOR'S PERMIT DOCUMENT" AND ARE NOT INTENDED TO COVER ALL AREAS OF CONTRACTUALAGREEMENT BETWEEN THE OWNER AND THE CONTRACTOR. SPECIFIC MATERIAL, FINISHES, FIXTURES, ALLOWANCES, ETC. NOT COVERED BY THESE PLANS SHOULD BE INCLUDED IN THE WRITTEN AGREEMENTBETWEEN THE OWNER AND THE CONTRACTOR.- ARCHITECT'S ROLE: CONSTRUCTION OBSERVATION AND PROJECT ADMINISTRATION ARE NOT PART OF ARCHITECT'S SCOPE OF WORK. ANY SITE VISITS BY ARCHITECT HAVE NO IMPLICATION OF ARCHITECTPERFORMING CONSTRUCTION OBSERVATION, UNLESS A WRITTEN AGREEMENT EXISTS FOR THIS PURPOSE.- WATERPROOFING/ AND FLASHING: DESIGN AND INSTALLATION OF ALL WATERPROOFING, FLASHING, AND ROOF/WALL COVERING ASSEMBLIES ARE THE RESPONSIBILITY OF THE CONTRACTOR. SELECTION OFALL PRODUCTS BY CONTRACTOR UNLESS SPECIFIED IN DRAWINGS.- SERVICE DUCTING: PROVIDE BATH EXHAUST FANS, DRYER, AND RANGE EXHAUST DUCTING TO EXTERIOR DISCHARGE TYP.SCOPE OF WORKCONTRACTOR SHALL PROVIDE SELECTION OF PRODUCT(S) AND DESIGN/ENGINEERING OF:- MECHANICAL + HVAC- INSULATION - THERMAL + SOUND- PLUMBING / WASTE; WATER SUPPLY/SEWER; SEPTIC TANK AND DRAIN FIELD IF REQ'D- ELECTRICAL PANEL SIZE; ELECTRICAL CIRCUITS DESIGN, ETC.- GUTTERS AND DOWNSPOUTS (IF SHOWN IN DRAWING(S)- POOL AND SCREEN CAGE (IF SHOWN IN DRAWINGS)ALL SYSTEMS TO COMPLY WITH THE REQUIREMENTS OF THE ARCHITECTURAL DRAWINGS AND PER LOCAL MUNICIPALITY'S CODE(S), FLA BUILDING CODE, AND ALL OTHERAPPLICABLE RULES AND LAWSTREES: CONTRACTOR AND/OR CLIENT SHALL COORDINATE TREE REMOVAL PERMITTING AND REMEDIATION/FEE REQUIREMENTS WITH MUNICIPALITYHVAC EXISTING CAPACITYEXISTING/ ADDITIONS: AT TIME OF BID CONTRACTOR SHALL EVALUATE CAPACITY OF EXISTING SYSTEM TO SATISFY ENERGY CODE REQUIREMENTS FOR NEWCONSTRUCTION AREAS. NOTIFY OWNER IF ADDITIONAL AIR CONDITIONING IS REQUIRED AND COORDINATE WITH OWNER PRICING/OPTIONS.A/C STATEMENTSCOPE STATEMENT: CONTRACTOR SHALL PROVIDE DESIGN AND ENGINEERING OF MECHANICAL SYSTEMS FOR BUILDING(S), TO COMPLY WITH THE REQUIREMENTS OFTHE ARCHITECTURAL DRAWINGS AND PER LOCAL MUNICIPALITY'S CODE(S) AND ALL OTHER APPLICABLE RULES AND LAWS. CONTRACTOR SHALL COORDINATE ALLDETAILS WITH OWNER AT JOBSITE MEETING WITH DRAWINGS AND/OR WRITTEN SPECIFICATION. CONTRACTOR SHALL RECEIVE WRITTEN APPROVAL FROM OWNERDEEMING ACCEPTANCE OF PROPOSED DESIGN PRIOR TO PROCEEDING WITH WORK.CONDENSATE DRAIN SYSTEMS: CONDENSATE DRAIN SYSTEMS SHALL BE PROVIDED FOR AIR HANDLERS. CONDENSATE SHALL BE CONVEYED TO AN APPROVED PLACE OFDISPOSAL:AUXILIARY DRAIN PANS: AUXILIARY DRAIN PANS SHALL BE INSTALLED UNDER ALL COILS ON WHICH CONDENSATION WILL OCCUR AND UNDER UNITS CONTAINING COILSTHAT ARE LOCATED IN ATTIC SPACES, SUSPENDED CEILING SPACES, FURRED SPACES, OR ANY AREA WHERE DAMAGE WILL OCCUR TO THE BUILDING OR BUILDINGCONTENTS, AS A RESULT OF AN OVERFLOW OF THE EQUIPMENT OR APPLIANCE DRAIN PAN OR A STOPPAGE IN THE PRIMARY CONDENSATE DRAIN PIPING. AUXILIARYDRAIN PANS SHALL HAVE A MIN. DEPTH OF 4", SHALL NOT BE LESS THAN 3" LARGER THAN THE UNIT OR COIL DIMENSIONS IN WIDTH AND LENGTH, AND SHALL BECONSTRUCTED OF AN APPROVED CORROSION RESISTANT MATERIAL.PROTECTION 1 OF 3 REQU'D: INSIDE THE DRAIN PAN, AN APPROVED FLOAT VALVE OR OTHER WATER LEVEL DETECTOR SHALL BE USED TO CONTROL OVERFLOW BYAUTOMATICALLY SHUTTING DOWN THE EQUIPMENT THAT PRODUCES THE CONDENSATE WHEN THE SWITCH ACTIVATES.PROTECTION 2 OF 3 REQU'D: A SEPARATE DRAIN LINE #1 SHALL EXTEND FROM THE TOP OF THE PAN (ABOVE THE FLOAT VALVE ACTIVATION LEVEL) TO A CONSPICUOUSPOINT AND SERVE AS AN ALARM WHICH INDICATES THAT THE PRIMARY DRAIN IS RESTRICTED AND THE FLOAT VALVE IS NOT FUNCTIONING.PROTECTION 3 OF 3 REQU'D: A SEPARATE DRAIN LINE #2 SHALL EXTEND FROM THE TOP OF THE PAN (ABOVE THE DRAINAGE LEVEL OF DRAIN LINE #1) TO A CONSPICUOUSPOINT AND SERVE AS AN ALARM WHICH INDICATES THAT THE PRIMARY DRAIN IS RESTRICTED AND THE FLOAT VALVE IS NOT FUNCTIONING.GENERAL NOTES: WIND CRITERIA: 130 MPH EXPOSURE:CALTERATION LEVEL: DOES NOT APPLY(DETACHED GUEST HOUSE)INDEXINSTALL GUTTER ANDDOWNSPOUT PERDRAINAGE PLAN BYOTHERSFOR FINALCONTOURS, SEEDRAINAGE PLANBY LEGENDENGINEERINGFOR FINALCONTOURS, SEEDRAINAGE PLANBY LEGENDENGINEERING985 sfSITE ACCESSTEMP TOILETDUMPSTERPARKINGMATERIAL STORAGE AREALOADING AREA