Loading...
275 SAILFISH DR ROOF23-0062 SKYLIGHTSBuilding Permit Application Updated 10/9/18 City of Atlantic Beach Building Department ALL INFORMATION 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY IS REQUIRED.Phone: (904) 247-5826 Email: Building-Dept@coab.us Job Address: 275 Sailfish Dr East Atlantic Beach FL 32233 Permit Number: G OP- Z.,3 -CO Legal Description 10- 8 17-2S-29E 2.0 SALTAIRSEC 1 LOTS 580,587 TO 592,NW 1/2 ST CLOSED RE# 170579-0010 iValuationofWork(Replacement Cost)$ Heated/Cooled SF Non-Heated/Cooled Class of Work: New Addition Alteration ®Repair Move Demo Pool Window/Door Use of existing/proposed structure(s): Commercial ®Residential If an existing structure,is a fire sprinkler system installed?: Yes No Will treels) be removed in association with proposed project? Yes(must submit separate Tree Removal Permit) No Describe in detail the type of work to be performed: 6 Sk I t h-t-s i Remove existing skylight and replace with new curb mounted skylightsZ AJGil'Ct( l L- JC)(t)- k Florida Product Approval# 13303 for multiple products use product approval form Property Owner Information Name MARSHPOINT MULTI FAMILY ONE LLC Address 275 Sailfish Dr East City Atlantic Beach State FL Zip 32233 Phone 407-217-3255 E-Mail jeanskyenterprises.com Owner or Agent(If Agent,Power of Attorney or Agency Letter Required) Contractor Information Name of Company Elo Roofing Inc Qualifying Agent Derek Williams Address 3415 Kori Rd City Jacksonville State FL Zip 32257 Office Phone 904-463-1606 Job Site Contact Number 904- 463-1606 State Certification/Registration# CCC1331535 E-Mail permitting@eloroofing.com Architect Name&Phone# Engineer's Name&Phone# Legacy Engineering 904-721-1100 Workers Compensation Insurer 1965470 OR Exempt NI Expiration Date 03/01/2024 Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE N RECORDING YO R NOTICE OF COMMENCEMENT. IN Signature of Owner or Agent) ature of Contractor) 4 o Signed and sworn to(or affirmed)before me this ( 1 day of Si ned a d swor ojor affirm-• befo e me this day of W .Q u , 2D73 ,by Dior.. ICoc*s S% , i,n3 ,by sfi1 fro, Signature of Notary) Signature o vo;" so YP /i Diana Kostas aN • ,, I ersonally Known OR ,a, •:M Comm.:HH 272673 maersonally Known •; Produced Identificatiois•' Expires:June 6,202. ro.uced Identification Type of Identification: % 4:;•••;%" a Type of Identification: loin" ' ' JOB COPY VELUX® Tui Ptuuuci Evaivaiiun4 fertifie ENERGY STAR dans les regionsen surbrlllanceVEL-N-20-00051-00002 SK-030NFRC : t t . .. . A.,: Skylight Model FCM (15) Canada t',..1 6,ss.„.",.:., Florida Prod.Approval v; Tempered over Tempered energystat:ge.oa i =1,,, ) s•'`a;, ,,,13303 0.02 LoE3,Argon-filled IGU 3 T-4-1-, \ National Fenestration r, Rating Council®t:; . Puits de lumiere modele FCM 15 , iP". 17..A7....... CERTIFIED Trempe sur trempei. a ,,,..,..,4,;..N5,....'':„.:` . 0.02 LoE3, unite disolation de verre rempli d'argon ENERGY: 0.S./Eu ENERGY PERFORMANCE RATINGS enetgystargov `u,; •• ;`: k.:e EVALUATION DU RENDEMENT ENERGETI•UE 4.....-U-Factor Do act pE6+o :Ull ,t,.,aa_ f:; :',NE .$ . :-t--re; >u-::Solar Heat Gain Coefficient 18.8 mm PaneValeur-U Coefficient de gain chaleur solaire Meets or Exceeds C.E.C.Air Infiltration Requirr n rots U.S./1-P) 0.49 WINDOW8DOOR hnnNUFACTURERSAssoclAnoN VELUX Model W D MAFCM 4646 0005Metric/SI) 2.780. 18Licensee:426-H-701V Hallmark Certified www.wdma.com Ratings for above size and smaller ADDITIONAL PERFORMANCE RATINGS Manufacturer Stipulates Conformance as indicated belowEVALUATIONSUPPLEMENTAIREDURENDEMENTSTANDARDRATING Visible Transmittance Air Leakage AAMA/WOMAJCSA SKG-PG100 KEEP LABEL FOR 0Transmission Visible Infiltration d'Air 10S.2JA440-11 Size Tested:1302 x 1295 51 x 51 in) Negative DP=6703 Paa((140 psf) CODE INSPECTION 1R 38 AND HOME RECORDS www.veluxusa.comU.S./I-P)Metric/SI) AAMAIWOMAJCSA Class CW-PG100 www.velux.caManufacturerstipulatesthattheseratingsconformtoapplicableNFRCproceduresfordeterminingwholeproductperformance. 10111.S.2/A440-0a Size Tested:1302 x 1295 mm(51 x 51 in) 1-$00-88-VELUXJFRCratingsaredeterminedforafixedsetofenvironmentalconditionsandaspecificproductsize.NFRC does not recommend Negative DP=5027 Pa(105 psf)ny product and does not warrantthe suitability of any productfor any spec Pic use.Consult manufacturers literature for product VELUX America Inc.ierformance Information www.nfrc.org PO BOX 5001 CSA A44OS1-09 DP:+47aHls027 Pa(+100I-105 pet)Greenwood, SC 29648donlelubricant,ces cotes soot conformes aux procedures applicables du NFRC servant h etabllr le rendement global du prodult.es coates NFRC sons dtablies selon les conditions envlronnementales et des dimensions de prodult spdcifilques.NFRCne Water Test Pressure=720 Pa(15 xed acommande aucun prodults et ne garantle aucun prodults dans leurs applications et recommendations dinstallations.Consulter la Canadian Air InfiltratiorrJExfiWadon=Fixed Leveltdraturedumanufacturierpourde(Information sur le rendement de tout autre produit. www.nfrc.org JOB COPY ENGLISH: Clearance around installations Vvi„cl _t_.. \—c_.*_.,_„, million ifiri )1' G A-F11,'Z w Onlb b 175 O i l aV ;' / 1150 mut 12" 12" 300 miii 300 mm be 450 mm Scanned with CamScanner JOB COPY ENGLISH:Center the skylight on top of the curb and ai secure with (4. x 45 mm)pan headfl-stainless steel screws provided.Screws will pen- etrate the curb by cess rre tot mm). AllowIIa. sk Apply downward securinge the top w o. the skylight frame while securing the screws. Do not overtighten the screws. ESPANOL:Centre el tragaluz sabre el brocal y fi- jelo con los tornillos de acero inoxidable de cabeza alrir dos.Los tornillos penetraran el brocal un minimo Aplique presion sobre el amazon del tragaluzMr/ mientras inserts los tornillos. No apriete demasiado los tornillos. i e W FRANC,AIS:Centres le puits de lumiere sur le cadre( 19 fixer- lemm). avec les vis cylindriques en acieret inoxydable#8 1W(4.2 x 45 mm)fournies.Les vis seront inserees dans le cadre d'au moins'/4" NW 19 mm). m Appliques une pression descendants sur la partie superieure du puits de lumiere lors de l'iNe pas seri des vis. Ne pas sewer les vis de faGon excessive.iffir,_____—_________________ *ifiti%aliralig LD 0 i maipi violi...L . _.iirlimmrir_ Scanned with CamScanner JOB COPY 4 ENGLISH:Wrap the sides anc the skylight curb with Junderlayment and create watt roofing underlayment. r^ <50°F , 16 NoteObservethemeasuremea150mm 10°C I ESPANOL:Envuelva los ladosp brocal del tragaluz con la lamip autoadhesiva para tragaluz VI I 1 cCCi6 solapas impermeabilizantes sc soporte del techo. I. ..— — Nota:Respete las medidas esi FRANC,AIS:Envelopper les CO MIN cadre du puits de lumiere avec• i urn toiture autocollante pour puits et former des rebords pour rev, par-dessus la membrane de tar L Note—Respecter les dimensions 6" 150 mm 4 1 72 113_mm p ENGLISH:Wrap the top and the 5 r -1 50°F skylight curb with urtadhes mmrimmmilmslimilliimiam / MIN I _ 10°C I layment and create proper wate ESPANOL:Envuelva las esquina 6"del brocal del tragaluz con lamirr 11, 50 mm IC I adhesiva para tragaluz VELUX p impermeabilizantes apropiadas. 1 FRANcAIS:Envelopper la partl coins du cadre du puits de lumiei brane de toiture autocollante po VELUX et former des rebords po trail de Peau. A 7-. EN H:To allow for pro.•. .13 mm i!..-.i.':4:.weave ro i s.= 'ent as s. for new co', i to m appli isns Interweave roofing y n in;1;1 ESPANOL:Para lograr un drenajc. 6a 6b Intercale la Iamina de soporte par se Indica en MI para construccior 1 010 aplicaclones posterlores,Intercale soporte para techos como se Indio sacci risr FRANCAIS:Pour assurer un drab f n entrecroiser avec la membrane de qu'lllustre a la figure M dans Ie cr tallation sur une nouvelle construc Installation sur une tolture existan avec la membrane de tolture.tel qt. figure. Scanned with CamScanner JOB COPY 3 2x41 r - - MI 50 °F I 10 °C 41C11- 1 75 mm MIN6" L J 150 mm 2 x 6 6" 1 0 mm 4 i 75mm MIN 6" 150 mm MIN 6" 150 mm 1i t 1/2" 13 mm Scanned with CamScanner JOB COPY I in ul. 7-7'-• idizr 144 Ika;: .0,11: :' ‘,4•;4774,:lik. ' 1 I rI' i 11) 1.• 0 8-4- d 1.44 L" •C 2 •R ''• di . zi---.: V t .. , • : ilii , u,.. ,,,,, , „ 3,.., .. ,, 14' • RIL•i(\4- ! 40) NVIorlif 11-1 i 1 r , Rust •esistant - Resistente a la corrosiOn •_-- • - \l':,", —.. ' .76,2 mm 7 kk, 7- r . 4t l' I t! -, . 1/4 • • 1 iip. . t. elk• • • 4... li- c • A ( lit . I .,0 . • Y""., 7 4,444t e • .r....c 4 N 1 1--.14 14, 111111. 1111110 ----r- -•\ • . ,Ta HILLMAN iurancL,- eloroo/ 1 r' 11,9i1 603 ' 0" 0 I A AV It g lin IME i7 44 1 1 ,4, wit,'01, if* . "4., ... • 1 *;u4 ii, it. 114, •,,1535-( 1 11.0),, 0 ity MI 4, . 404 • i '''."14.110100, ghl VI . r!.- , . ii. op/. tif• , ill., ."1/40194110,,,4 A Iwo i VI044,,4%.,iiaL Atk. loop,///, ---% -# 4itt. lf,IP.11.4°4 i, '-.......mw;40,,i 4044' te i CD01i4iir,40„ mil ilb: d46"Illei gti t ' tki.414 IL-. de CDfi' ''' i*v•'r h.A IL r t4;111'1 14E.OM iP' /270 4 I .41- • -.- 4.s. JOB COPY El 8 H i9 s ,i 4 1, i1/2"/38mm t'w'o 3 ii NW i3R -C4 i/c/lefi 70 -Me 104, c'"41 O#7' G',P min 31/4 ' 3 1/ min 90 mm JOB COPY