Loading...
193 Beach Ave ROOF23-0001 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: SHORECREST CONDOMINIUM ASSOCIATION OF JACKSONVILLE INC PO BOX 330026 ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: STONEBRIDGE CONSTRUCTION 6956 PHILLIPS PARKWAY DR N JACKSONVILLE FL 32258 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 170314 1004 SHORECREST CONDOMINIUM JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 193 BEACH AVE ROOF NON SHINGLE SHINGLE AND MODIFIED ROOFING - BUILDINGS 1 & 3 $39906.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: IN-PROGRESS INSPECTIONS ARE REQUIRED FOR EXTERIOR SIDING, WINDOW, AND DOOR INSPECTIONS, AND SHOULD BE SCHEDULED FOR THE FIRST DAY OF WORK. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 8/22/2023 PERMIT NUMBER ROOF23-0001 ISSUED: 8/22/2023 EXPIRES: 2/18/2024 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $250.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $125.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $5.63 STATE DCA SURCHARGE 455-0000-208-0600 0 $3.75 TOTAL: $384.38 2 BUILDING NOTICE OF COMMENCEMENT INFORMATIONAL Notes: No inspections may be scheduled until a copy a recorded Notice of Commencement has been submitted to the Building Department 2 of 2Issued Date: 8/22/2023 PERMIT NUMBER ROOF23-0001 ISSUED: 8/22/2023 EXPIRES: 2/18/2024 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION SHINGLE AND MODIFIED ROOFING - BUILDINGS 1 & 3 193 BEACH AVE STONEBRIDGE CONSTRUCTION ROOF23-0001 ROOF23-0001 ROOF23-0001NOT FILED ROOF23-0001 NEMO|etc. NEMO ETC, LLC P.E. EVALUATION REPORT: 7TH EDITION (2020) FBC NON-HVHZ PEER-GAF-009.A for FL5293-R55 Certificate of Authorization #32455 GAF EverGuard TPO Roof Systems; (800) 766-3411 Revision 56: 04/10/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 1 of 156 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 7 1B Wood New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 8 1C Wood New, Reroof (Tear-Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 10 1D Wood New, Reroof (Tear-Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 12 1E Wood New, Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 13 1F Wood New, Reroof (Tear-Off) or Recover C-2 Induction-Welded Roof Cover 16 1G Wood New, Reroof (Tear-Off) or Recover D-1 Insulated, Mechanically Attached Roof Cover 17 1H Wood New, Reroof (Tear-Off) or Recover D-2 Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 18 1I Wood New, Reroof (Tear-Off) or Recover E-1 Non-Insulated, Mechanically Attached Roof Cover 18 1J Wood New, Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 19 2A Steel New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 21 2B Steel or Structural concrete New, Reroof (Tear-Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 21 2C Steel or Structural concrete New, Reroof (Tear-Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Base and Cap Ply 34 2D Steel New or Reroof (Tear-Off) B-2 Mech. Attached Thermal Barrier, Bonded Vapor Barrier, Bonded Insulation, Bonded Roof Cover 35 2E Steel or Structural concrete New, Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 43 2F Steel or Structural concrete New, Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Base and Cap Ply 75 2G Steel or Structural concrete New, Reroof (Tear-Off) or Recover C-1A Thermal Barrier with Vapor Barrier, Mechanically Attached Insulation, Bonded Roof Cover 76 2H Steel or Structural concrete New, Reroof (Tear-Off) or Recover C-2 Induction-Welded Roof Cover 81 2I Steel or Structural concrete New, Reroof (Tear-Off) or Recover D-1 Insulated, Mechanically Attached Roof Cover 84 2J Steel or Structural concrete New, Reroof (Tear-Off) or Recover D-2 Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 88 3A Structural concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 89 3B Structural concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Base and Cap Ply 105 3C Structural concrete New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 107 4A Lightweight concrete / concrete New or Reroof (Tear-Off) A-1 LWC to Deck, Bonded Insulation, Bonded Roof Cover 108 4B Lightweight concrete / steel New or Reroof (Tear-Off) A-2 LWC to Deck, Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 110 4C Lightweight concrete / concrete New or Reroof (Tear-Off) A-2 LWC to Deck, Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 110 4D Lightweight concrete / steel or concrete New or Reroof (Tear Off) E-2 LWC to Deck, Mechanically Attached Base Sheet, Bonded Roof Cover 112 4E Lightweight concrete / steel New or Reroof (Tear Off) F LWC to Deck, Bonded Roof Cover 113 4F Lightweight concrete / concrete New or Reroof (Tear Off) F LWC to Deck, Bonded Roof Cover 114 4G Lightweight concrete / concrete New or Reroof (Tear Off) F Vapor Barrier to Deck, LWC to Vapor Barrier, Bonded Roof Cover 115 5A Cementious wood fiber New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 115 5B Cementious wood fiber New, Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 117 5C Cementitious wood fiber New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 117 6A Existing gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 118 6B Existing gypsum Reroof (Tear-Off) A-2 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 120 6C Existing gypsum Reroof (Tear-Off) B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 120 6D Existing gypsum Reroof (Tear-Off) C-1 Mechanically Attached Insulation, Bonded Roof Cover 125 6E Existing gypsum Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 126 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 127 7B Wood or Steel Recover C-2 Induction-Welded Roof Cover 154 7C Steel Recover D-1 Insulated, Mechanically Attached Roof Cover 154 7D Various Recover F Non-Insulated, Bonded Roof Cover 156 ROOF23-0001 NEMO|etc. NEMO ETC, LLC P.E. EVALUATION REPORT: 7TH EDITION (2020) FBC NON-HVHZ PEER-GAF-009.A for FL5293-R55 Certificate of Authorization #32455 GAF EverGuard TPO Roof Systems; (800) 766-3411 Revision 56: 04/10/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 2 of 156 The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2 Unless otherwise noted, fasteners and stress plates shall be as follows. Fasteners shall be of sufficient length for the following engagements: FASTENER/PLATE OPTIONS DECK TYPE BY PARTS MINIMUM ENGAGEMENT Wood GAF Drill-Tec #12 Fastener, Drill-Tec #12 DP Fastener, Drill-Tec #12 DPH Fastener, Drill-Tec #14 Fastener or Drill-Tec #14 HD Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate, Drill-Tec AccuTrac Recessed Plate (insulation only), Drill-Tec 3” Flat Steel Plate or Drill-Tec 3” Recessed Steel Plate; Drill-Tec ASAP 3S; Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate; Drill-Tec 3” ASAP Flat or Drill-Tec 3” ASAP Recessed Minimum ¾-inch plywood penetration or minimum 1- inch wood plank embedment Steel GAF Drill-Tec #12 Fastener, Drill-Tec #12 DP Fastener, Drill-Tec #12 DPH Fastener, Drill-Tec #14 Fastener, Drill-Tec #14 HD Fastener, Drill-Tec XHD Fastener or Drill-Tec #15 EHD Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only), Drill-Tec 3” Flat Steel Plate or Drill-Tec 3” Recessed Steel Plate; Drill-Tec ASAP 3S; Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate; Drill-Tec Extra Heavy Duty ASAP Roofing Fastener – Insulation; ; Drill-Tec 3” ASAP Flat or Drill-Tec 3” ASAP Recessed Minimum ¾-inch steel penetration and engage the top flute of the steel deck Note: Unless otherwise noted, Drill Tec #12 DF Fastener or Drill Tec #14 DF Fastener with Drill Tec 3” DF Steel Insulation Plate may be used in place of Drill-Tec #12 Fastener or Drill-Tec #14 Fastener with Drill-Tec 3” Standard Steel Plate when used to secure DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Ultralight Coated Glass-Mat Roof Board to steel deck, up to a maximum allowable design pressure (MDP) of -120.0 psf. Note: Unless otherwise noted, Drill Tec #12 DF Fastener or Drill Tec #14 DF Fastener with Drill Tec 3” DF Steel Insulation Plate may be used in place of Drill-Tec #12 Fastener or Drill-Tec #14 Fastener with Drill-Tec 3” Standard Steel Plate when used to secure min. 0.5-inch thick Structodek High Density Fiberboard Roof Insulation, EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation, 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or min. 1.5-inch EnergyGuard POLYISO INSULATION or EnergyGuard Ultra Polyiso Insulation to steel deck. Structural Concrete GAF Drill-Tec #14 Fastener, Drill-Tec #14 HD Fastener or Drill-Tec CD-10 with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only), Drill-Tec 3” Flat Steel Plate or Drill-Tec 3” Recessed Steel Plate; Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate or Drill-Tec 3” ASAP Flat (#14 only) Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer’s published installation instructions Note: Unless otherwise noted, Drill Tec #14 DF Fastener with Drill Tec 3” DF Steel Insulation Plate may be used in place of Drill-Tec #14 Fastener with Drill-Tec 3” Standard Steel Plate when used to secure min. DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Ultralight Coated Glass-Mat Roof Board to structural concrete deck, up to a maximum allowable design pressure (MDP) of -120.0 psf. Note: Unless otherwise noted, Drill Tec #14 DF Fastener with Drill Tec 3” DF Steel Insulation Plate may be used in place of Drill-Tec #14 Fastener with Drill-Tec 3” Standard Steel Plate when used to secure min. 0.5-inch thick Structodek High Density Fiberboard Roof Insulation, EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation, 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or min. 1.5-inch EnergyGuard POLYISO INSULATION or EnergyGuard Ultra Polyiso Insulation to structural concrete deck. 3 Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4 Minimum 200 psi, minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for, or installed below, rigid insulation board for System Types B-1, C-1, C-2, D-1 or D-2, whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-related issues, such as deck venting or moisture levels within the LWIC and the potential effect on overlying components. 5 Preliminary insulation attachment: Unless otherwise noted, use FBC Approved roofing fasteners and plates and refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29. 6 Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions. If applying hot asphalt to concrete deck, deck shall be primed with ASTM D41 primer. When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered. The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. NEMO|etc. NEMO ETC, LLC P.E. EVALUATION REPORT: 7TH EDITION (2020) FBC NON-HVHZ PEER-GAF-009.A for FL5293-R55 Certificate of Authorization #32455 GAF EverGuard TPO Roof Systems; (800) 766-3411 Revision 56: 04/10/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 3 of 156 INSULATION ADHESIVE REFERENCES BY ADHESIVE REFERENCE FBC FILE OR NOA MINIMUM RATE GAF GAF LRF Adhesive M ‘LRF-M’ NOA 18-0521.05 Continuous 0.75 to 1-inch ribbons, 12-inch o.c. GAF GAF LRF Adhesive XF ‘LRF-XF’ N/A Continuous 0.75 to 1-inch ribbons, 12-inch o.c. OMG, Inc. OlyBond 500 Adhesive Fastener ‘OB500’ FL1608 Continuous 0.75-inch wide ribbons, 12-inch o.c. (PaceCart, SpotShot or Canister) Generic, ASTM D312, Type IV hot asphalt N/A N/A Full coverage at 25-30 lbs/square 7 Unless otherwise noted, all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. MDP LIMITATIONS FOR TAPERED POLYISOCYANURATE INSULATIONS ADHESIVE INSULATION MIN. TAPERED THICKNESS (IN) MDP (PSF) LISTED PRODUCT FBC FILE OR NOA LRF-M EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation FL16311 0.5 -232.5 LRF-XF EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation FL16311 0.5 -292.5 LRF-XF EnergyGuard RA 18-0220.10 0.5 -487.5 OB500 EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation FL16311 0.5 -292.5 OB500 EnergyGuard RH 19-1017.09 0.5 -315.0 OB500 EnergyGuard RN 18-1126.10 0.5 -315.0 OB500 EnergyGuard RA 18-0220.10 0.5 -487.5 Hot asphalt Any EnergyGuard polyisocyanurate listed with adhesive herein Various 0.5 -240.0 8 For adhered roof insulation and board-size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29. 9 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 for Zone 2/3 enhancements. 10 For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11 For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1 the base insulation layer is optional and for System Type C-2, D-1 or D-2, the insulation is optional. Alternatively, an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5). The separator component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. NEMO|etc. NEMO ETC, LLC P.E. EVALUATION REPORT: 7TH EDITION (2020) FBC NON-HVHZ PEER-GAF-009.A for FL5293-R55 Certificate of Authorization #32455 GAF EverGuard TPO Roof Systems; (800) 766-3411 Revision 56: 04/10/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 4 of 156 14 Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For “pre-existent” LWIC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami-Dade BCCO (FBC CER1592). Use of these listings in new construction or re-roof (tear-off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15 For bonded membrane applications, unless otherwise noted, refer to the following. MEMBRANE / ADHESIVE COMBINATIONS REFERENCE MEMBRANE ADHESIVE APPLICATION RATE TPOFDM-SA EverGuard Freedom TPO self-adhering self-adhering self-adhering TPO-SA EverGuard SA TPO self-adhering self-adhering self-adhering TPO-1121 EverGuard TPO EverGuard TPO 1121 Bonding Adhesive Contact (both sides) 0.8 to 1.0 gal/square/surface. For use over SECUROCK Gypsum-Fiber Roof Board, the application rate changes to 1.2 to 1.67 gal/sq/surface TPO-3SQ EverGuard TPO EverGuard TPO 3 Square Low VOC Bonding Adhesive Contact (both sides) 0.84 gal/square/surface TPO-6SQ EverGuard TPO EverGuard TPO 6 Square Low VOC Bonding Adhesive Contact (both sides) 0.46 gal/square/surface TPO-QSA EverGuard TPO EverGuard TPO Quick Spray Adhesive Contact (both sides) Total application rate: ~0.71 lbs/sq (dry rate). TPO-QSALV50 EverGuard TPO EverGuard TPO Quick Spray Adhesive LV 50 Contact (both sides) Total application rate: ~0.84 lbs/sq (dry-rate). TPO-WB EverGuard TPO EverGuard WB181 Bonding Adhesive Contact (both sides) To polyisocyanurate or Structodek High Density Fiberboard Roof Insulation, Fiber Base HD1 or Fiber Base HD6 at 0.63 gal/square and roof cover underside at 0.21 gal/square. To DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board at 0.63 to 0.75 gal/square and roof cover underside at 0.21 to 0.25 gal/square TPOFB-HA1 EverGuard TPO Fleece-Back Membrane hot asphalt Wet lay (substrate) 25 lbs/square TPOFB-HA2 EverGuard TPO Fleece-Back Membrane 100, 115 or 135 TPOFB-LM1 EverGuard TPO Fleece-Back Membrane GAF LRF Adhesive M Wet lay (substrate) 1-inch wide ribbons spaced as noted in tables herein. Note: The adhesive ribbons are located directly over the adhesive ribbons used to secure the insulation when the cover is bonded to insulation less than 1.5-inch thick. TPOFB-LM2 EverGuard TPO Fleece-Back Membrane 100, 115 or 135 TPOFB-LO1 EverGuard TPO Fleece-Back Membrane GAF LRF Adhesive O Wet lay (substrate) 1-inch wide ribbons spaced as noted in tables herein. Note: The adhesive ribbons are located directly over the adhesive ribbons used to secure the insulation when the cover is bonded to insulation less than 1.5-inch thick. TPOFB-LO2 EverGuard TPO Fleece-Back Membrane 100, 115 or 135 TPOFB-OB1 EverGuard TPO Fleece-Back Membrane OlyBond 500 Canister Wet lay (substrate) “Spatter pattern” at 0.32 gal/square (to insulation, coverboard or Tectum) “Spatter pattern” at 0.83 gal/square (to asphaltic base ply membrane). TPOFB-OB2 EverGuard TPO Fleece-Back Membrane 100, 115 or 135 TPOFB-XF1 EverGuard TPO Fleece-Back Membrane GAF LRF Adhesive XF Wet lay (substrate) “Spatter pattern” at 3.0 lbs/sq. TPOFB-XF2 EverGuard TPO Fleece-Back Membrane 100, 115 or 135 TPOFB-WB EverGuard TPO Fleece-Back Membrane EverGuard WB181 Bonding Adhesive Wet lay (substrate) 0.83 to 1.0 gal/square BP-AA One or two plies GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet or GAFGLAS #80 Ultima Base Sheet Hot asphalt 25 lbs/square SBS-AA One or two plies Ruberoid 20 Smooth, Ruberoid Mop Smooth or Ruberoid Mop Smooth 1.5 Hot asphalt 25 lbs/square SBS-SA LIBERTY SBS Self-Adhering Cap Sheet Self-adhering Full bond SBS-TA One or two plies Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch-applied Full bond NEMO|etc. NEMO ETC, LLC P.E. EVALUATION REPORT: 7TH EDITION (2020) FBC NON-HVHZ PEER-GAF-009.A for FL5293-R55 Certificate of Authorization #32455 GAF EverGuard TPO Roof Systems; (800) 766-3411 Revision 56: 04/10/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 5 of 156 15A For single-ply membranes in System Type D-1 steel deck applications, the roof membrane shall be run with its length perpendicular to the steel deck flutes. 15B For System Type C-2 (induction weld), care shall be taken to ensure that the plates do not line-up with membrane seams. This condition may preclude proper induction welding of the membrane to the plates. 15C The “Triposite Roofing System” noted herein consists of loose-laid GAFGLAS Stratavent Perforated Venting Base Sheet, followed by asphalt-applied one (1) or two (2) plies of Ruberoid 20 Smooth or three (3) plies of GAFGLAS FlexPly 6 or GAFGLAS FlexPly 6 M, followed by asphalt-applied EverGuard TPO Fleece-Back Membrane or EverGuard TPO Fleece-Back Membrane 100, 115 or 135 with 1-5/8” heat welded side laps. 15D Unless otherwise noted, the “Hybrid Roofing System” noted herein consists of asphalt-applied Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet or GAFGLAS #80 Ultima Base Sheet followed by asphalt-applied EverGuard TPO Fleece-Back Membrane or EverGuard TPO Fleece-Back Membrane 100, 115 or 135. 16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MDP limitations. The lesser of the MDP listings below vs. that of the selected assembly applies. VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; FOLLOWED BY ADHESIVE-APPLIED INSULATION OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE PER TABLE 3A OR 3B MDP (PSF) TYPE (NOTE 15) APPLICATION C-VB-1. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch-applied Hot asphalt -225.0 C-VB-2. Matrix 307 Premium Asphalt Primer or ASTM D41 primer BP-AA Hot asphalt applied Hot asphalt -360.0 C-VB-3. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6 or GAFGLAS FlexPly 6 M or SBS-AA Hot asphalt applied Hot asphalt -495.0 C-VB-4. None GAF SA Vapor Retarder XL Self-adhering LRF-M, 12-inch o.c. -112.5 C-VB-5. Matrix 307 Premium Asphalt Primer or ASTM D41 primer SBS-TA Torch-applied LRF-M, 12-inch o.c. -180.0 C-VB-6. GAF SA Primer, TPO QSA or TPO QSA LV50 GAF SA Vapor Retarder Self-adhering LRF-M, 12-inch o.c. -202.5 C-VB-7. Matrix 307 Premium Asphalt Primer or ASTM D41 primer BP-AA, one or two GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6 or GAFGLAS FlexPly 6 M or SBS-AA Hot asphalt applied LRF-M, 12-inch o.c. -495.0 C-VB-8. None GAF SA Vapor Retarder XL Self-adhering LRF-XF 12-inch o.c. -112.5 C-VB-9. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch-applied LRF-XF, 12-inch o.c. -169.0 C-VB-10. Matrix 307 Premium Asphalt Primer or ASTM D41 primer SBS-TA Torch-applied LRF-XF, 12-inch o.c. -180.0 C-VB-11. GAF SA Primer, TPO QSA or TPO QSA LV50 GAF SA Vapor Retarder Self-adhering LRF-XF, 12-inch o.c. -202.5 C-VB-12. Matrix 307 Premium Asphalt Primer or ASTM D41 primer SBS-SA Self-adhering LRF-XF, 12-inch o.c. -250.0 C-VB-13. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6 or GAFGLAS FlexPly 6 M or one ply Ruberoid 20 Smooth Hot asphalt applied LRF-XF, 12-inch o.c. -262.5 C-VB-14. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 30 Hot asphalt applied LRF-XF, 12-inch o.c. -270.0 C-VB-15. None GAF SA Vapor Retarder XL Self-adhering OB500, 12-inch o.c. -127.5 C-VB-16. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Smooth Torch-applied OB500, 12-inch o.c. -165.0 C-VB-17. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth Torch-applied OB500, 12-inch o.c. -180.0 C-VB-18. Matrix 307 Premium Asphalt Primer or ASTM D41 primer SBS-SA Self-adhering OB500, 12-inch o.c. -187.5 C-VB-19. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 20 Smooth Matrix 102 SBS Membrane Adhesive at 1.5 gal/square OB500, 12-inch o.c. -202.5 C-VB-20. GAF SA Primer, TPO QSA or TPO QSA LV50 GAF SA Vapor Retarder Self-adhering OB500, 12-inch o.c. -202.5 C-VB-21. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch-applied OB500, 12-inch o.c. -225.0 C-VB-22. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW Smooth Torch-applied OB500, 12-inch o.c. -232.5 NEMO|etc. NEMO ETC, LLC P.E. EVALUATION REPORT: 7TH EDITION (2020) FBC NON-HVHZ PEER-GAF-009.A for FL5293-R55 Certificate of Authorization #32455 GAF EverGuard TPO Roof Systems; (800) 766-3411 Revision 56: 04/10/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 6 of 156 VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; FOLLOWED BY ADHESIVE-APPLIED INSULATION OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE PER TABLE 3A OR 3B MDP (PSF) TYPE (NOTE 15) APPLICATION C-VB-23. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6 or GAFGLAS FlexPly 6 M or one ply Ruberoid 20 Smooth Hot asphalt applied OB500, 12-inch o.c. -352.5 16A Vapor barrier options for use over structural concrete deck followed by cellular lightweight concrete carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. that of the selected assembly applies. VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK FOLLOWED BY CELLULAR LIGHTWEIGHT INSULATING CONCRETE OPTION # PRIMER VAPOR BARRIER LIGHTWEIGHT CONCRETE PER TABLE 4A – 4G (Note 14) MDP (PSF) TYPE ATTACH LWC-VB-1. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Base Ply (Optional): One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth Cap Ply: Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR Torch- applied Min. 200 psi Mearlcrete (FL13492) -82.5 LWC-VB-2. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Base Ply (Optional): One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth Cap Ply: Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR Torch- applied Min. 300 psi Celcore Cellular Concrete (FL2037) -135.0 LWC-VB-3. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Base Ply (Optional): One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth Cap Ply: Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR Torch- applied Min. 300 psi Elastizell (NOA 18-0208.03) -302.5 LWC-VB-4. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth, Ruberoid HW Smooth Torch- applied Min. 540 psi pre-existent cellular LWC -358.0 17 Fire barriers of FireOut™ Fire Barrier Coating or VersaShield Solo™ Fire-Resistant Slip Sheet are optional in all assemblies when overlying components are mechanically fastened. 18 The following products are interchangeable within the scope of this PEER: ACCEPTABLE ALTERNATES SUB-CATEGORY MANUFACTURER FBC FILE OR NOA LISTED PRODUCT HEREIN ALTERNATE ROOFING INSULATION GAF FL16311 EnergyGuard Polyiso Insulation EnergyGuard NH Polyiso Insulation EnergyGuard Ultra Polyiso Insulation EnergyGuard NH Ultra Polyiso Insulation EnergyGuard HD Polyiso Cover Board EnergyGuard HD Barrier Polyiso Cover Board, EnergyGuard NH HD Polyiso Cover Board EnergyGuard HD Plus Polyiso Cover Board EnergyGuard NH HD Plus Polyiso Cover Board Georgia-Pacific Gypsum, LLC FL1250 DensDeck Prime DensDeck StormX Prime Roof Board VAPOR BARRIER GAF N/A GAF SA Vapor Retarder XL GAF SA Vapor Retarder XL40 19 For System Types B-1, B-2, C-1, C-2, D-1 or D-2, GAF SA Vapor Retarder or GAF SA Vapor Retarder XL may be installed atop the roof deck, or to a loose-laid thermal barrier of DensDeck Prime or SECUROCK Gypusm-Fiber Roof Board, prior to installation of the insulation and roof cover. When adhering GAF SA Vapor Retarder to structural concrete, the substrate shall be primed with GAF SA Primer, TPO QSA or TPO QSA LV50. When adhering GAF SA Vapor Retarder to DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board, the substrate shall be primed with GAF SA Primer, TPO QSA, TPO QSA LV50 or Matrix 307 Premium Asphalt Primer. Refer to FM Loss Prevention Data Sheet 1-29 for design and installation limitations. 20 “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. (Notes 9 and 10) NEMO|etc. NEMO ETC, LLC P.E. EVALUATION REPORT: 7TH EDITION (2020) FBC NON-HVHZ PEER-GAF-009.A for FL5293-R55 Certificate of Authorization #32455 GAF EverGuard TPO Roof Systems; (800) 766-3411 Revision 56: 04/10/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 13 of 156 TABLE 1D: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) W-47. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 3-inch EnergyGuard Ultra Note 2 1 per 1.0 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF, 4-inch o.c. TPOFB-OB1 -120.0 W-48. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 3-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.0 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4-inch o.c. TPOFB-OB1 -120.0 TABLE 1E: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attach Base Cap EVERGUARD SA TPO: W-49. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard Polyiso-HD Composite Insulation or Ultra HD Composite Insulation Note 2 1 per 1.45 ft2 None TPO-SA -52.5 W-50. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.3 ft2 None TPO-SA -60.0 EVERGUARD TPO: W-51. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard Polyiso-HD Composite Insulation or Ultra HD Composite Insulation Note 2 (#14 Fastener only) 1 per 2.7 ft2 None TPO-1121, TPO-3SQ, TPO-6SQ, TPO-QSA or TPO-QSALV50 -37.5* W-52. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard Polyiso-HD Composite Insulation or Ultra HD Composite Insulation Note 2 (#14 Fastener only) 1 per 2.7 ft2 None TPO-1121, TPO-3SQ, TPO-6SQ, TPO-QSA or TPO-QSALV50 -45.0* W-53. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 (#14 Fastener only) 1 per 2.7 ft2 None TPO-1121, TPO-3SQ, TPO-6SQ, TPO-QSA or TPO-QSALV50 -45.0* W-54. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard Polyiso-HD Composite Insulation or Ultra HD Composite Insulation Note 2 (#14 Fastener only) 1 per 2.0 ft2 None TPO-1121, TPO-3SQ, TPO-6SQ, TPO-QSA or TPO-QSALV50 -45.0* W-55. APA rated, 19/32 CAT, 0.578 in., Exposure 1 OSB; 2 ft span (Optional) One or more layers, any combination Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard Polyiso-HD Composite Insulation or Ultra HD Composite Insulation Note 2 (#14 Fastener only) 1 per 2.0 ft2 None TPO-1121, TPO-3SQ, TPO-6SQ, TPO-QSA, TPO-QSALV50 or TPO- WB -45.0* Black DiamonD ® Base sheet heat-actiVateD selF-aDheReD sBs-moDiFieD Base sheet FoR hYBRiD RooF sYstems Product Use: Black Diamond® Base Sheet is designed for use as a heat-activated, self-adhered base sheet for hybrid roof systems with a torch-applied cap or cap set in hot asphalt for modified bitumen or built-up roofing systems. It is suitable for use in both new construction and reroofing over a variety of substrates1, including but not limited to insulation, concrete and plywood/OSB2. Black Diamond Base Sheet delivers measurable labor savings over traditional fully adhered asphaltic membranes without compromising waterproofing protection. Black Diamond Base Sheet also may be used as a vapor retarder under roof insulation and may be left exposed for up to six months without asphalt degradation. This versatile base ply can be used in CertainTeed two-ply, low-slope roofing systems for up to 20-year warranty durations (see CertainTeed Commercial Roof System Specifications for details). Precautions: Black Diamond Base Sheet is attached by a self-adhering method. It is not intended for attachment with hot asphalt, cold adhesive, coal tar pitch or mechanical fasteners. Black Diamond Base Sheet relies on heat-activation to achieve its full bond; it must be installed with either a torch-applied cap sheet or cap sheet set in hot asphalt. It cannot be paired with a self-adhered cap sheet or one set in cold adhesive. Rolls should be stored upright off the ground and completely protected from the weather. Do not attempt application if ice, snow, moisture or dew are present. Surface to be bonded to must be clean, dry and free from any dust or deterrent to adhesion. Do not attempt installation on roofs without adequate slope and drainage. Product composition and Features: Black Diamond Base Sheet is manufactured using a dimensionally-stable, fiberglass reinforced mat, saturated and coated with a superior grade of SBS-modified bitumen compound on the top of the sheet and a proprietary pressure sensitive SBS-modified bitumen adhesive on the back of the sheet. It is surfaced on the bottom with a removable release film and on the top with highly UV stable, black slag particles. Roll Dimensions: 39⅜" X 68' 7" (225 square feet) nominal coverage: Two squares approximate Weight: 78 lbs. top surface: Fine black slag particles Back surface: Release film applicable standards: Meets ASTM D1970 and ASTM D4601, Type 1. Black Diamond Base Sheet is approved by Underwriters Laboratories for use in various Class A, B and C roof assemblies, Factory Mutual, Miami-Dade, Florida Building Code Statewide Approval (FL 2533 and FL 16709) and Texas Department of Insurance (RC-47). Packaging: Black Diamond Base Sheet rolls are individually packaged in corrugated boxes. The following information represents typical average properties of Black Diamond Base Sheet. modified Bitumen coating: Non-oxidized (flux) asphalt, blended with a compatible elastomeric styrene-butadiene-styrene polymer and selected inert fillers. support mat: Dimensionally-stable, fiberglass reinforced mat. 1See CertainTeed Commercial Roof Systems Specifications manual for all approved substrates. 2When directly adhering to wood or OBS, priming is required; direct adhesion to plywood or OSB is not permitted by code in Miami-Dade County (check your local building code); at the end of the roofing membrane’s life, roofing membranes directly adhered to wood roof decks will require replacement of the deck. Product information technical Data technical Product Data technical Product Data ROOF23-0001 test Description test method Results* thickness: ASTM D1970 1.4 mm (55 mils) tensile strength: ASTM D5147 @ 73.4 +/- 3.6°F MD/XD 50/30 lbs./in. h2o absorption: 0.1% Dimensional stability: ASTM D5147 MD 0.1%/XD 0.1% adhesion to Plywood: ASTM D1970 30 lbs./ft. tear strength: ASTM D5147 MD/XD 80/50 lbs./in. *NOTE: Published results are nominal production values confirmed by independent laboratory testing. CertainTeed offers material and/or material/workmanship (No Dollar Limit) limited warranties. Warranty type and duration is dependent on roof system configuration and contractor selection. Only CertainTeed Gold and Silver Star Contractors are eligible to apply for No Dollar Limit (NDL) limited warranties on specific roof projects. CertainTeed provides technical assistance in the product selection, specification and application guidelines for all CertainTeed commercial roof systems. Field representatives are available for consultation in each region. For more information, contact CertainTeed Commercial Roofing Technical Services at 800-396-8134 ext. 2 or rpg.comm.services@saint-gobain.com technical assistance and services Warranties technical Data (cont'd) CertainTeed CEILINGS • DECKING • FENCE • GYPSUM • INSULATION • RAILING • ROOFING • SIDING • TRIM 20 Moores Road Malvern, PA 19355 Professional: 800-233-8990 Consumer: 800-782-8777 certainteed.com ©03/20 CertainTeed, Printed in the USA, Code No. COMM-021 Technical Product Data FLINTLASTIC ® GTA APP MODIFIED BITUMEN POLYESTER CAP SHEET WITH MINERAL SURFACE Product Use: Flintlastic GTA is designed for use as a cap membrane over various types of substrates for both new construction and reroofing installations. It is suitable for most low sloped roof decks and may be used for roof system flashings including wall treatments, base flashings and field flashings. Limitations: Flintlastic GTA is intended for torch application only and should not be exposed to adhesives or solvent based materials. Rolls should be stored upright, off the ground and completely protected from the weather. Roof decks must be structurally sound, dry, smooth and meet or exceed minimum requirements of the deck manufacturer, local code and CertainTeed. Additional specifications and precautions are contained in the CertainTeed Commercial Roof Systems Specifications. Product Composition and Features: Flintlastic modified bitumen membranes are manufactured on state-of-the-art, dedicated roofing lines that were exclusively designed for the production of modified bitumen products. Flintlastic GTA is produced with a high performance, stress- resistant polyester mat that is impregnated and coated with a superior grade, modified bitumen compound. Roll Dimensions: 39 ⅜" X 32' 10" Nominal Coverage: One square Approximate Weight: 103 Ibs. per roll Top Surface: Mineral granule Back Surface: Torchable polyethylene film Applicable Standards: Meets ASTM D6222, Grade G, Type I. Flintlastic GTA is approved by Underwriters Laboratories for use in various Class A, B and C roof assemblies, ICC-ES (ESR-1388), Factory Mutual, Miami-Dade, Florida Building Code Statewide Approval (FL 2533 and FL 16709) and Texas Department of Insurance (RC-47). Flintlastic GTA White is an approved ENERGY STAR® product for slopes greater than 2”/12”. Flintlastic GTA White is listed by the Cool Roof Rating Council (CRRC). The CRRC product ID is 0668-0008. Initial Solar Reflectance: 0.27; Aged Solar Reflectance: 0.27; Thermal Emittance: 0.87. Modified Bitumen Coating: Non-oxidized (flux) asphalt, blended with various thermoplastic atactic polypropylene polymers and co-polymers. Support Mat: High performance, stress-resistant polyester mat. Test Description Test Method Results* Solar Reflectance Index (SRI) Initial/Aged: ASTM E1980 27/28 Softening Point: ASTM D36 310°F Tensile Strength: ASTM D5147 @ 73.4 +/- 3.6°F MD/XD 100/60 lbs./in. @ 0 +/- 3.6°F MD/XD 130/80 lbs./in. Elongation: ASTM D5147 @ 73.4 +/- 3.6°F MD/XD 45%/55% @ 0 +/- 3.6°F MD/XD 30%/20% Dimensional Stability: ASTM D5147 MD/XD 0.5%/0.3% Low Temperature Flex: ASTM D5147 Pass @ 8°F Compound Stability: ASTM D5147 250°F Thickness: ASTM D5147 4.0 mm (160 mils) Tear Strength: ASTM D5147 @ 73.4 +/- 3.6°F MD/XD 130/90 lbs. *NOTE: Published results are nominal production values confirmed by independent laboratory testing. Product Information Technical Data ROOF23-0001 Flintlastic modified bitumen roofing systems must be applied in accordance with installation procedures contained in the CertainTeed Commercial Roof Systems Specifications. The following information is intended for general information purposes only and is not all-inclusive. Preparation: Substrates to receive a roof system must be firmly attached, smooth, dry, clean and free of sharp projections and depressions. Substrates requiring priming must be primed with asphalt primer such as FlintPrime® and be allowed to completely dry. Substrates must provide positive drainage. Roof must be tapered to drains. Installation: Install one ply of Glasbase™ or other CertainTeed approved alternate base sheet lapping 2" on sides and 4" on ends. Base sheet must be mechanically fastened to nailable substrates, and either solid or spot mopped in hot asphalt to non-nailable or insulated substrates as specified in the CertainTeed Commercial Roof Systems Specifications. Apply base sheet in such a manner as to provide and maintain a minimum 6" offset between side and end laps of base ply and Flintlastic finishing membrane. Over the base ply, install one ply of Flintlastic GTA lapping 3" on sides and 6" on ends, with end laps diagonally staggered not less than 3' apart. Side and end laps should be inspected to ensure a minimum ⅜" flow of modified compound has been achieved. Precautions: Cold weather applications require special handling to prevent damage to the rolls and ensure satisfactory installation. Do not apply roofing systems over improperly prepared substrates or substrates that contain moisture. Follow all safety recommendations relating to the use and maintenance of liquid propane gas torches and equipment. Refer to the CertainTeed Commercial Roof Systems Specifications for additional safety information. Maintenance: Flintlastic Roof Systems do not require any additional maintenance beyond normal yearly roof maintenance procedures. CertainTeed recommends regular roof maintenance and inspection to determine the condition of drains, flashings and other similar items, and to prolong the life expectancy of the roof system. CertainTeed offers Limited (product only) and No Dollar Limit (NDL, product and workmanship) warranties. Warranty type and duration is dependent on roof system configuration and contractor selection. Only CertainTeed Gold and Silver Star Contractors are eligible to apply for NDL warranties on specific roof projects. For more information, see CertainTeed Commercial Roof Systems Specifications or contact Commercial Roofing Technical Services. CertainTeed provides technical assistance in the design, selection, specification and application guidelines for all CertainTeed Roof Systems. Architectural and field representatives are available for consultation within each region. For more information, contact CertainTeed Commercial Roofing Technical Services at 800-396-8134 x2. Torch application of this product may create a risk of fire, including smoldering fires. The roofing applicator is solely responsible for ensuring and enforcing safe and proper application of CertainTeed’s roofing products by competent and qualified personnel. Only properly trained roofing professionals are authorized to install this product. Never apply flame directly to combustible materials or allow the flame to enter into hidden or protected areas that may contain combustible materials. Follow all local code requirements. Have a Class A-B-C fire extinguisher available to each applicator. Thoroughly inspect the job site whenever torching equipment has been used. Be certain that all chances of a fire have been eliminated. Refer to the CertainTeed Commercial Roof Systems Specifications, Midwestern Roofing Contractors Association (MRCA) CERTA program, National LP Gas Association, National Roofing Contractors Association (NRCA), National Fire Protection Association (NFPA), and Asphalt Roofing Manufacturers Association (ARMA) for further information and safety recommendations. Technical Assistance and Services Warranties Caution:Fire Hazard Product Application www.certainteed.com http://blog.certainteed.com CertainTeed Corporation 20 Moores Road Malvern, PA 19355 Professional: 800-233-8990 Consumer: 800-782-8777 © 03/16 CertainTeed Corporation, Printed in the U.S.A. Code No. COMM-020 ASK ABOUT ALL OF OUR OTHER CERTAINTEED® PRODUCTS AND SYSTEMS: ROOFING • SIDING • TRIM • DECKING • RAILING • FENCE GYPSUM • CEILINGS • INSULATION