Loading...
1802 HICKORY LN RES23-0167 FL14429.2 (2)_1SHEET:DWG. #:1AWD112 BUILDING DROPS, INC. 398 E. DANIA BEACH BLVD., STE. 338 DANIA BEACH, FL 33004 PH: (954)399-8478 FAX: (954)744.4738 WEB: www.buildingdrops.comOFSCALE:NTSSMDWG. BY:DATE:09.28.17CHK. BY:HFNREMARKSTITLE:BY DATETHE INSTALLATION DETAILS DESCRIBED HEREINARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONSFOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATIONTO DEVIATEFROM THE REQUIREMENTS DETAILED HEREIN, A LICENSEDENGINEER OR ARCHITECT SHALLPREPARE SITE SPECIFIC DOCUMENTS FOR USEWITH THIS DOCUMENT200 SERIES NARROLINE GLIDING PATIO DOOR (NON-HVHZ)(NON-IMPACT) 9/30/2020 12:08 PMs:\projects\andersen windows\cc-20-0224 - code change - fbc 2020 (version 7) code change\revisions\fl14429\dwgs\14429.2\awd112 200 series narroline gpd.dwg 10FL14429FL #:PREPARED BY:HERMES F. NORERO, P.E.FLORIDA P.E. No 73778BUILDING DROPS, INC398 E. DANIA BEACH BLVD. # 338DANIA BEACH, FL 33004FBPE CERT. OF AUTHORIZATION No. 29578100 FOURTH AVE NORTHBAYPORT, MN 55003-1096PH: (651) 264-5150 FX: (651) 264-54857TH FBC CODE CHANGE SR 3.18.20GENERAL NOTES:1. THE PRODUCT SHOWN HEREIN IS DESIGNED ANDMANUFACTURED TO COMPLY WITH THE CURRENT FLORIDABUILDING CODE (FBC), EXCLUDING HVHZ AND HAS BEENEVALUATED ACCORDING TO THE FOLLOWING:·AAMA/WDMA/CSA 101/I.S.2/A440-112. ADEQUACY OF THE EXISTING STRUCTURALCONCRETE/MASONRY, 2X AND METAL STUD FRAMING ASA MAIN WIND FORCE RESISTING SYSTEM CAPABLE OFWITHSTANDING AND TRANSFERRING APPLIED PRODUCTLOADS TO THE FOUNDATION IS THE RESPONSIBILITY OFTHE ENGINEER OR ARCHITECT OF RECORD FOR THEPROJECT OF INSTALLATION.3. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED ANDANCHORED TO PROPERLY TRANSFER ALL LOADS TO THESTRUCTURE. BUCK DESIGN AND INSTALLATION IS THERESPONSIBILITY OF THE ENGINEER OR ARCHITECT OFRECORD FOR THE PROJECT OF INSTALLATION.4. THE INSTALLATION DETAILS DESCRIBED HEREIN AREGENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FORA SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATIONTO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN,A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITESPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT.5. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED TOPROTECT THIS PRODUCT IN AREAS REQUIRING IMPACTRESISTANCE.6. DOOR MATERIAL: WOOD, LVL, AND VINYL7. GLASS MEETS THE REQUIREMENTS OF ASTM E1300 GLASSCHARTS. SEE SHEET 8 FOR GLAZING DETAILS.8. DESIGNATIONS "X" AND "O" STAND FOR THE FOLLOWING:X: ACTIVE PANELO: STATIONARY PANEL9. CUSTOM SIZES AVAILABLE UPON REQUEST. CUSTOMDESIGN PRESSURE WILL BE ASSIGNED EQUAL TO NEXTLARGER STANDARD SIZE.INSTALLATION NOTES:1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHORLOCATION SHOWN, UNLESS OTHERWISE STATED.2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THEMINIMUM NUMBER OF ANCHORS TO BE USED FOR PRODUCTINSTALLATION.3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN ATOLERANCE OF ±1/2 INCH OF THE DEPICTED LOCATION IN THEANCHOR LAYOUT DETAIL (I.E., WITHOUT CONSIDERATION OFTOLERANCES). TOLERANCES ARE NOT CUMULATIVE FROM ONEINSTALLATION ANCHOR TO THE NEXT.4.THROUGH FRAME: FOR INSTALLATION INTO 2X BUCK OR FRAMINGUSE #10 WOOD SCREWS OF SUFFICIENT LENGTH TO ACHIEVE 1 1/2INCH MINIMUM EMBEDMENT INTO WOOD SUBSTRATE ANDMAINTAIN MINIMUM 3/4" EDGE DISTANCE.5.THROUGH FRAME: FOR INSTALLATION THROUGH 1X BUCK TOCONCRETE/MASONRY, OR DIRECTLY INTO CONCRETE/MASONRY,USE 316" ITW TAPCONS OF SUFFICIENT LENGTH TO ACHIEVE 1 1/4INCH MINIMUM EMBEDMENT AND MAINTAIN MINIMUM 2" EDGEDISTANCE.10. THROUGH FRAME: FOR INSTALLATION INTO METAL SUBSTRATESUSE #10 GRADE 5 SELF-DRILLING OR SELF-TAPPING SCREWS OFSUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUMPENETRATION BEYOND METAL FRAME SUBSTRATE AND MAINTAINMINIMUM 3/4" EDGE DISTANCE.11. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALLFINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICKVENEER, AND SIDING.12. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BEMADE OF CORROSION RESISTANT MATERIAL OR HAVE ACORROSION RESISTANT COATING.13. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOTINSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS.EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OREDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK.14. INSTALLATION ANCHORS SHALL BE INSTALLED INACCORDANCE WITH ANCHOR MANUFACTURER'SINSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USEDIN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUMSTRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER.15. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTSHEREIN ARE BASED ON SUBSTRATE MATERIALS WITH THEFOLLOWING PROPERTIES:A. WOOD - MINIMUM SPECIFIC GRAVITY OF 0.55.B. CONCRETE -MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI.C. GROUT-FILLED CMU- UNIT STRENGTH CONFORMS TO ASTM C-90WITH MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI AND GROUTCONFORMS TO ASTM C 476, MINIMUM GROUT COMPRESSIVESTRENGTH OF 2000 PSI.D. HOLLOW BLOCK CMU - UNIT STRENGTH CONFORMS TO ASTM C-90WITH MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI.E. STEEL - MINIMUM YIELD STRENGTH OF 33 KSI. MINIMUMWALL THICKNESS OF 33 MILS (20 GAUGE).F. ALUMINUM - MINIMUM 6063-T5 ALLOY. MINIMUM WALLTHICKNESS OF 1/8".ANDERSEN CORPORATION200 SERIES NARROLINE GLIDING PATIO DOOR(NON-HVHZ)(NON-IMPACT) GENERAL AND INSTALLATION NOTESTABLE OF CONTENTSSHEETSHEET DESCRIPTION1GENERAL AND INSTALLATION NOTES2ELEVATION & ANCHOR LAYOUT OXXO3ELEVATIONS & ANCHOR LAYOUTS OX, O4VERTICAL SECTIONS OXXO5VERTICAL SECTIONS XO6VERTICAL SECTIONS O7HORIZONTAL SECTIONS8HORIZONTAL SECTIONS & GLAZING DETAILS9SIDELITE MULLIONS10MULLION ANCHOR DETAILDESIGN PRESSURE RATINGPRODUCT O.A. SIZE CONFIGURATION DESIGN PRESSUREMISSILEIMPACTRATINGNLGD4380S IG50" X 95 12"O+40.0 / -40.0 PSFNON-IMPACTNLGD6068AS IG71 14" X 79 12"XO+35.0 / -35.0 PSFNLGD6080AS IG71 14" X 95 12"XO+30.0 / -30.0 PSFNLGD8080AS IG95 12" X 95 12"XO+25.0 / -25.0 PSFNLGD16080SAAS IG189" X 95 12"OXXO+25.0 / -25.0 PSFNLGD60611AS IG71 14" X 82 38"XO+40.0 / -40.0 PSF ELEVATIONANCHOR LAYOUTTHROUGH FRAMEINSTALLATION10" MAX.FROM CORNERSSEE ANCHORSCHEDULE CHARTUNIT MAX.WIDTH 189.00"UNITMAX.HEIGHT95.50"PANELMAX.HEIGHT92.125"D.L.OMAX.HEIGHT86.625"XXOOPANEL MAX.WIDTH 48.00"D.L.O. MAX.WIDTH 42.50"4C7BA48A7BB48BOOXXSET ENTIRE SILL IN BED OF STRUCTURALSILICONE SEALANT, (MIN THREE 1/2" BEADS)10" FROMCORNERSSEE ANCHORSCHEDULE CHART4DOPP.8BOPP.OPP.10" FROMCORNERSSEE ANCHORSCHEDULE CHARTSHEET:DWG. #:2AWD112 BUILDING DROPS, INC. 398 E. DANIA BEACH BLVD., STE. 338 DANIA BEACH, FL 33004 PH: (954)399-8478 FAX: (954)744.4738 WEB: www.buildingdrops.comOFSCALE:NTSSMDWG. BY:DATE:09.28.17CHK. BY:HFNREMARKSTITLE:BY DATETHE INSTALLATION DETAILS DESCRIBED HEREINARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONSFOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATIONTO DEVIATEFROM THE REQUIREMENTS DETAILED HEREIN, A LICENSEDENGINEER OR ARCHITECT SHALLPREPARE SITE SPECIFIC DOCUMENTS FOR USEWITH THIS DOCUMENT200 SERIES NARROLINE GLIDING PATIO DOOR (NON-HVHZ)(NON-IMPACT) 9/30/2020 12:08 PMs:\projects\andersen windows\cc-20-0224 - code change - fbc 2020 (version 7) code change\revisions\fl14429\dwgs\14429.2\awd112 200 series narroline gpd.dwg 10FL14429FL #:PREPARED BY:HERMES F. NORERO, P.E.FLORIDA P.E. No 73778BUILDING DROPS, INC398 E. DANIA BEACH BLVD. # 338DANIA BEACH, FL 33004FBPE CERT. OF AUTHORIZATION No. 29578100 FOURTH AVE NORTHBAYPORT, MN 55003-1096PH: (651) 264-5150 FX: (651) 264-54857TH FBC CODE CHANGE SR 3.18.20 ELEVATIONS & ANCHOR LAYOUTS OXXO XOUNIT MAX.WIDTH 95.50"UNITMAX.HEIGHT95.50"PANELMAX.HEIGHT92.125"D.L.OMAX.HEIGHT86.625"PANEL MAX.WIDTH 48.00"D.L.O. MAX.WIDTH 42.50"5D7AB57B5CA58BELEVATIONOX10" MAX.FROM CORNERSSEE ANCHORSCHEDULE CHART10" MAX. FROMCORNERSSEE ANCHORSCHEDULE CHARTANCHOR LAYOUTTHROUGH FRAMEINSTALLATIONSET ENTIRE SILL IN BED OFSTRUCTURAL SILICONE SEALANT,(MIN THREE 1/2" BEADS)OUNIT MAX.WIDTH 50.00"UNITMAX.HEIGHT95.50"PANELMAX.HEIGHT92.125"D.L.OMAX.HEIGHT86.625"PANEL MAX.WIDTH 48.00"D.L.O. MAX.WIDTH 42.50"7C6B6A7CELEVATIONOANCHOR LAYOUTTHROUGH FRAMEINSTALLATION10" MAX.FROM CORNERSSEE ANCHORSCHEDULE CHART10" MAX. FROMCORNERSOPP.SHEET:DWG. #:3AWD112 BUILDING DROPS, INC. 398 E. DANIA BEACH BLVD., STE. 338 DANIA BEACH, FL 33004 PH: (954)399-8478 FAX: (954)744.4738 WEB: www.buildingdrops.comOFSCALE:NTSSMDWG. BY:DATE:09.28.17CHK. BY:HFNREMARKSTITLE:BY DATETHE INSTALLATION DETAILS DESCRIBED HEREINARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONSFOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATIONTO DEVIATEFROM THE REQUIREMENTS DETAILED HEREIN, A LICENSEDENGINEER OR ARCHITECT SHALLPREPARE SITE SPECIFIC DOCUMENTS FOR USEWITH THIS DOCUMENT200 SERIES NARROLINE GLIDING PATIO DOOR (NON-HVHZ)(NON-IMPACT) 9/30/2020 12:08 PMs:\projects\andersen windows\cc-20-0224 - code change - fbc 2020 (version 7) code change\revisions\fl14429\dwgs\14429.2\awd112 200 series narroline gpd.dwg 10FL14429FL #:PREPARED BY:HERMES F. NORERO, P.E.FLORIDA P.E. No 73778BUILDING DROPS, INC398 E. DANIA BEACH BLVD. # 338DANIA BEACH, FL 33004FBPE CERT. OF AUTHORIZATION No. 29578100 FOURTH AVE NORTHBAYPORT, MN 55003-1096PH: (651) 264-5150 FX: (651) 264-54857TH FBC CODE CHANGE SR 3.18.20 ELEVATIONS & ANCHOR LAYOUTS OX, O 3/4" MIN EDGEDISTANCE3/8" MAX.SHIM SPACESEALANT BETWEENCONCRETE/ MASONRY & 2X WOOD BUCK BY OTHERSCONCRETE/ MASONRYBY OTHERSINTERIOREXTERIOR1-1/2" MIN.EMBEDMENT3/8" MAX.SHIM SPACE3/4" MIN EDGEDISTANCE2X WOOD FRAMING& SHEATHING BY OTHERSEXTERIOR FINISHBY OTHERSPERIMETER SEALANTBY OTHERS4THROUGH FRAMEVERTICAL SECTIONHEAD - 2X WOOD FRAMINGB4THROUGH FRAMEVERTICAL SECTIONHEAD - 2X WOOD/CONCRETE/MASONRYA4THROUGH FRAMEVERTICAL SECTIONSILL - CONCRETECEXTERIORINTERIORO.A.UNITHEIGHTO.A.UNITHEIGHT2X WOOD BUCKBY OTHERSEXTERIOR FINISHBY OTHERSEXTERIORINTERIOR4THROUGH FRAMEVERTICAL SECTIONSILL - 2X WOODDEXTERIORINTERIORO.A.UNITHEIGHTO.A.UNITHEIGHTPERIMETER SEALANTBY OTHERSSET SILL IN BED OFSTRUCTURAL SILICONE SEALANT(MIN THREE 12" BEADS)SEE GLAZINGDETAILS, SHEET 8SEE GLAZINGDETAILS, SHEET 8SEE GLAZINGDETAILS, SHEET 8SEE GLAZINGDETAILS, SHEET 8CONCRETE/ MASONRYBY OTHERSSEALANT BETWEENFLANGE AND SUBSTRATE1-1/2" MIN.EMBEDMENTSET SILL IN BED OFSTRUCTURAL SILICONE SEALANT(MIN THREE 12" BEADS)2X WOOD FRAMINGBY OTHERSEXTERIOR FINISH/BLOCKING/DECKINGBY OTHERS#10 WOOD SCREWINSTALLATION ANCHOR#10 WOOD SCREWINSTALLATION ANCHORSEALANT BETWEENFLANGE AND 2X WOODNOTE:FASTENERS REQUIRED AT SILL FOR 4-PANELUNITS AND MULLED UNITS ONLY.1-1/2" MIN.EMBEDMENT2" MIN EDGEDISTANCE316" ITW TAPCONINSTALLATION ANCHOR1-1/2" MIN.EMBEDMENT3/4" MIN EDGEDISTANCE#10 WOOD SCREWINSTALLATION ANCHORSHEET:DWG. #:4AWD112 BUILDING DROPS, INC. 398 E. DANIA BEACH BLVD., STE. 338 DANIA BEACH, FL 33004 PH: (954)399-8478 FAX: (954)744.4738 WEB: www.buildingdrops.comOFSCALE:NTSSMDWG. BY:DATE:09.28.17CHK. BY:HFNREMARKSTITLE:BY DATETHE INSTALLATION DETAILS DESCRIBED HEREINARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONSFOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATIONTO DEVIATEFROM THE REQUIREMENTS DETAILED HEREIN, A LICENSEDENGINEER OR ARCHITECT SHALLPREPARE SITE SPECIFIC DOCUMENTS FOR USEWITH THIS DOCUMENT200 SERIES NARROLINE GLIDING PATIO DOOR (NON-HVHZ)(NON-IMPACT) 9/30/2020 12:08 PMs:\projects\andersen windows\cc-20-0224 - code change - fbc 2020 (version 7) code change\revisions\fl14429\dwgs\14429.2\awd112 200 series narroline gpd.dwg 10FL14429FL #:PREPARED BY:HERMES F. NORERO, P.E.FLORIDA P.E. No 73778BUILDING DROPS, INC398 E. DANIA BEACH BLVD. # 338DANIA BEACH, FL 33004FBPE CERT. OF AUTHORIZATION No. 29578100 FOURTH AVE NORTHBAYPORT, MN 55003-1096PH: (651) 264-5150 FX: (651) 264-54857TH FBC CODE CHANGE SR 3.18.20 VERTICAL SECTIONS OXXO 3/4" MIN EDGEDISTANCE3/8" MAX.SHIM SPACE#10 SELF-DRILLING SCREWINSTALLATION ANCHORMETAL STUD & SHEATHINGFRAMING BY OTHERSINTERIOREXTERIOR1-1/2" MIN.EMBEDMENT3/8" MAX.SHIM SPACE2" MIN EDGEDISTANCEEXTERIOR FINISHBY OTHERSPERIMETER SEALANTBY OTHERS5THROUGH FRAMEVERTICAL SECTIONHEAD - 1X WOOD/CONCRETE/MASONRYB5THROUGH FRAMEVERTICAL SECTIONHEAD - METAL SUBSTRATEA5THROUGH FRAMEVERTICAL SECTIONSILL - CONCRETECEXTERIORINTERIORO.A.UNITHEIGHTO.A.UNITHEIGHTEXTERIOR FINISHBY OTHERSEXTERIORINTERIOR5THROUGH FRAMEVERTICAL SECTIONSILL - 2X WOODDEXTERIORINTERIORO.A.UNITHEIGHTO.A.UNITHEIGHTPERIMETER SEALANTBY OTHERSSET SILL IN BED OFSTRUCTURAL SILICONE SEALANT(MIN THREE 1/2" BEADS)SEE GLAZINGDETAILS, SHEET 8SEE GLAZINGDETAILS, SHEET 8SEE GLAZINGDETAILS, SHEET 8SEE GLAZINGDETAILS, SHEET 8SEALANT BETWEENFLANGE AND SUBSTRATETHREE THREADSMIN. PENETRATIONBEYOND METALSET SILL IN BED OFSTRUCTURAL SILICONE SEALANT(MIN THREE 1/2" BEADS)EXTERIOR FINISH/BLOCKING/DECKINGBY OTHERSSEALANT BETWEENFLANGE AND SUBSTRATE1X WOOD BUCK BYOTHERS (OPTIONAL)CONCRETE/ MASONRYBY OTHERSSEALANT BETWEENCONCRETE/ MASONRY & 2X WOOD BUCK BY OTHERS3/16" ITW TAPCONINSTALLATION ANCHORNOTE: FLANGE MAY BE TRIMMED/CUTDOWN TO FIT 1X BUCK OR REMOVED FORDIRECT TO MASONRY INSTALLATION.CONCRETE/ MASONRYBY OTHERS3/16" ITW TAPCONINSTALLATION ANCHOR2X WOOD FRAMINGBY OTHERS#10 WOOD SCREWINSTALLATION ANCHORSHEET:DWG. #:5AWD112 BUILDING DROPS, INC. 398 E. DANIA BEACH BLVD., STE. 338 DANIA BEACH, FL 33004 PH: (954)399-8478 FAX: (954)744.4738 WEB: www.buildingdrops.comOFSCALE:NTSSMDWG. BY:DATE:09.28.17CHK. BY:HFNREMARKSTITLE:BY DATETHE INSTALLATION DETAILS DESCRIBED HEREINARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONSFOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATIONTO DEVIATEFROM THE REQUIREMENTS DETAILED HEREIN, A LICENSEDENGINEER OR ARCHITECT SHALLPREPARE SITE SPECIFIC DOCUMENTS FOR USEWITH THIS DOCUMENT200 SERIES NARROLINE GLIDING PATIO DOOR (NON-HVHZ)(NON-IMPACT) 9/30/2020 12:08 PMs:\projects\andersen windows\cc-20-0224 - code change - fbc 2020 (version 7) code change\revisions\fl14429\dwgs\14429.2\awd112 200 series narroline gpd.dwg 10FL14429FL #:PREPARED BY:HERMES F. NORERO, P.E.FLORIDA P.E. No 73778BUILDING DROPS, INC398 E. DANIA BEACH BLVD. # 338DANIA BEACH, FL 33004FBPE CERT. OF AUTHORIZATION No. 29578100 FOURTH AVE NORTHBAYPORT, MN 55003-1096PH: (651) 264-5150 FX: (651) 264-54857TH FBC CODE CHANGE SR 3.18.20 VERTICAL SECTIONS OX 3/4" MIN EDGEDISTANCE3/8" MAX.SHIM SPACE#10 SELF-DRILLING SCREWINSTALLATION ANCHORMETAL STUD & SHEATHINGFRAMING BY OTHERS6THROUGH FRAMEVERTICAL SECTIONHEAD - METAL SUBSTRATEA6THROUGH FRAMEVERTICAL SECTIONSILL - CONCRETEBEXTERIORINTERIORO.A.UNITHEIGHTO.A.UNITHEIGHTEXTERIOR FINISHBY OTHERSEXTERIORINTERIORPERIMETER SEALANTBY OTHERSSET SILL IN BED OFSTRUCTURAL SILICONE SEALANT(MIN THREE 1/2" BEADS)CONCRETE/ MASONRYBY OTHERSTHREE THREADSMIN. PENETRATIONBEYOND METALSEALANT BETWEENFLANGE AND SUBSTRATESEE GLAZINGDETAILS, SHEET 8SEE GLAZINGDETAILS, SHEET 83/16" ITW TAPCONINSTALLATION ANCHORSHEET:DWG. #:6AWD112 BUILDING DROPS, INC. 398 E. DANIA BEACH BLVD., STE. 338 DANIA BEACH, FL 33004 PH: (954)399-8478 FAX: (954)744.4738 WEB: www.buildingdrops.comOFSCALE:NTSSMDWG. BY:DATE:09.28.17CHK. BY:HFNREMARKSTITLE:BY DATETHE INSTALLATION DETAILS DESCRIBED HEREINARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONSFOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATIONTO DEVIATEFROM THE REQUIREMENTS DETAILED HEREIN, A LICENSEDENGINEER OR ARCHITECT SHALLPREPARE SITE SPECIFIC DOCUMENTS FOR USEWITH THIS DOCUMENT200 SERIES NARROLINE GLIDING PATIO DOOR (NON-HVHZ)(NON-IMPACT) 9/30/2020 12:08 PMs:\projects\andersen windows\cc-20-0224 - code change - fbc 2020 (version 7) code change\revisions\fl14429\dwgs\14429.2\awd112 200 series narroline gpd.dwg 10FL14429FL #:PREPARED BY:HERMES F. NORERO, P.E.FLORIDA P.E. No 73778BUILDING DROPS, INC398 E. DANIA BEACH BLVD. # 338DANIA BEACH, FL 33004FBPE CERT. OF AUTHORIZATION No. 29578100 FOURTH AVE NORTHBAYPORT, MN 55003-1096PH: (651) 264-5150 FX: (651) 264-54857TH FBC CODE CHANGE SR 3.18.20 VERTICAL SECTIONS 7THROUGH FRAMEHORIZONTAL SECTIONJAMB - METAL STUD FRAMEAEXTERIORINTERIOR3 THREADS MIN.PENETRATION BEYOND METALMETAL STUDFRAMING BY OTHERS3/8" MAX.SHIM SPACESHEATHINGBY OTHERSEXTERIOR FINISHBY OTHERSPERIMETER SEALANTBY OTHERS#10 SELF-DRILLING SCREWINSTALLATION ANCHOR7THROUGH FRAMEHORIZONTAL SECTIONJAMB - 2X WOOD BUCKBSEE GLAZINGDETAILS, SHEET 8O.A. UNITWIDTH3/4" MIN.EDGE DISTANCE1-1/2" MIN.EMBEDMENT3/8" MAX.SHIM SPACE3/4" MIN.EDGE DISTANCEEXTERIOR FINISHBY OTHERSPERIMETER SEALANTBY OTHERS2X WOOD BUCKBY OTHERS#10 WOOD SCREWINSTALLATION ANCHORO.A. UNITWIDTHSEE GLAZINGDETAILS, SHEET 8INTERIOREXTERIORSEALANT BETWEENCONCRETE/ MASONRY & 2XWOOD BUCK BY OTHERSSEALANT BETWEENFLANGE AND SUBSTRATE1-1/2" MIN.EMBEDMENT3/8" MAX.SHIM SPACE2" MIN EDGEDISTANCEEXTERIOR FINISHBY OTHERSPERIMETER SEALANTBY OTHERSSEALANT BETWEENFLANGE AND SUBSTRATE1X WOOD BUCK BYOTHERS (OPTIONAL)CONCRETE/ MASONRYBY OTHERSSEALANT BETWEENCONCRETE/ MASONRY & 2X WOOD BUCK BY OTHERS3/16" ITW TAPCONINSTALLATION ANCHOR7THROUGH FRAMEHORIZONTAL SECTIONJAMB - 1X WOOD/CONCRETE/MASONRYCEXTERIORINTERIORSEE GLAZINGDETAILS, SHEET 8O.A. UNITWIDTHSEALANT BETWEENFLANGE AND SUBSTRATENOTE: FLANGE MAY BE TRIMMED/CUTDOWN TO FIT 1X BUCK OR REMOVED FORDIRECT TO MASONRY INSTALLATION.SHEET:DWG. #:7AWD112 BUILDING DROPS, INC. 398 E. DANIA BEACH BLVD., STE. 338 DANIA BEACH, FL 33004 PH: (954)399-8478 FAX: (954)744.4738 WEB: www.buildingdrops.comOFSCALE:NTSSMDWG. BY:DATE:09.28.17CHK. BY:HFNREMARKSTITLE:BY DATETHE INSTALLATION DETAILS DESCRIBED HEREINARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONSFOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATIONTO DEVIATEFROM THE REQUIREMENTS DETAILED HEREIN, A LICENSEDENGINEER OR ARCHITECT SHALLPREPARE SITE SPECIFIC DOCUMENTS FOR USEWITH THIS DOCUMENT200 SERIES NARROLINE GLIDING PATIO DOOR (NON-HVHZ)(NON-IMPACT) 9/30/2020 12:08 PMs:\projects\andersen windows\cc-20-0224 - code change - fbc 2020 (version 7) code change\revisions\fl14429\dwgs\14429.2\awd112 200 series narroline gpd.dwg 10FL14429FL #:PREPARED BY:HERMES F. NORERO, P.E.FLORIDA P.E. No 73778BUILDING DROPS, INC398 E. DANIA BEACH BLVD. # 338DANIA BEACH, FL 33004FBPE CERT. OF AUTHORIZATION No. 29578100 FOURTH AVE NORTHBAYPORT, MN 55003-1096PH: (651) 264-5150 FX: (651) 264-54857TH FBC CODE CHANGE SR 3.18.20 HORIZONTAL SECTIONS 8HORIZONTAL SECTIONMEETING STILESA8HORIZONTAL SECTIONINTERLOCKBINTERIOREXTERIORSEE GLAZINGDETAILS, SHEET 8INTERIOREXTERIORSEE GLAZINGDETAILS, SHEET 83/4" O.A. INSULATEDTEMPERED GLASS9/16" GLASSBITEGLAZING DETAIL 1INTERIOREXTERIORDESICCANT FILLEDMETAL SPACERSILICONE BACK BED1-1/2" FINISHING NAILS2" FROM CORNERS & 8-1/2" O.C.NOTE:1. ALL GLAZING MEETS SAFETY GLAZING REQUIREMENTSAS PER CH 24 OF THE FBC.2. SETTING BLOCK DUROMETER HARDNESS OF 70-90(SHORE A) AS REFERENCED IN CHAPTER 24.3. SETTING BLOCKS TO BE LOCATED AT 1/4 SPAN LENGTHFOR GLASS WIDER THAN 36" AS PER CHAPTER 24.4. D.L.O. MAY NOT EXCEED MAX DIMENSIONS SHOWN INELEVATIONS.SHEET:DWG. #:8AWD112 BUILDING DROPS, INC. 398 E. DANIA BEACH BLVD., STE. 338 DANIA BEACH, FL 33004 PH: (954)399-8478 FAX: (954)744.4738 WEB: www.buildingdrops.comOFSCALE:NTSSMDWG. BY:DATE:09.28.17CHK. BY:HFNREMARKSTITLE:BY DATETHE INSTALLATION DETAILS DESCRIBED HEREINARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONSFOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATIONTO DEVIATEFROM THE REQUIREMENTS DETAILED HEREIN, A LICENSEDENGINEER OR ARCHITECT SHALLPREPARE SITE SPECIFIC DOCUMENTS FOR USEWITH THIS DOCUMENT200 SERIES NARROLINE GLIDING PATIO DOOR (NON-HVHZ)(NON-IMPACT) 9/30/2020 12:08 PMs:\projects\andersen windows\cc-20-0224 - code change - fbc 2020 (version 7) code change\revisions\fl14429\dwgs\14429.2\awd112 200 series narroline gpd.dwg 10FL14429FL #:PREPARED BY:HERMES F. NORERO, P.E.FLORIDA P.E. No 73778BUILDING DROPS, INC398 E. DANIA BEACH BLVD. # 338DANIA BEACH, FL 33004FBPE CERT. OF AUTHORIZATION No. 29578100 FOURTH AVE NORTHBAYPORT, MN 55003-1096PH: (651) 264-5150 FX: (651) 264-54857TH FBC CODE CHANGE SR 3.18.20 HORIZONTAL SECTIONS & GLAZING DETAILS NOTE:1) MULLION CHART APPLIES TO MULLION ASSEMBLIES, SEE TYP. DETAIL A/9, WHEN USED TO MULLDOORS IN CONFIGURATIONS SHOWN IN TYP. ELEVATION A AT RIGHT (2 PANEL XO ONLY).2) DESIGN PRESSURE VALUES ARE POSITIVE AND NEGATIVE IN PSF.3) MAXIMUM DEFLECTION HAS BEEN LIMITED TO L/175.4) DESIGN PRESSURE OF ASSEMBLY IS LIMITED TO THE LESSER DESIGN PRESSURE OF THEJAMB-TO-JAMB WOOD MULLION OR THE INDIVIDUAL DOOR UNIT OF INSTALLATION.5) MULLION CHART ABOVE APPLIES TO MULLED ASSEMBLIES CONSISTING OF 200 SERIESNARROLINE GLIDING PATIO DOOR ACT-STAT UNITS AND STAT UNITS.6) ADJACENT DOORS SHALL BE FASTENED TO THE ROUGH OPENING WITH ADDITIONAL ANCHORS INACCORDANCE WITH DETAILS A/10 & B/10, SHEET 10.BALWELEVATION ATRIBUTARY WIDTH = W = (A+B)/29HORIZONTAL SECTIONNLGPD STAT - NLGPDA200 SERIES NLGPD STATEXTERIOR VINYLTRIM STRIPINTERIOR VINYLTRIM STRIPBEAD OF SILICONE#10 X 1 5/8" SCREWS15" MAX. O.C.,THROUGH EA. JAMB1" OFFSET200 SERIES NLGPDO OR XO OR XOMAXIMUM DESIGN PRESSURE CAPACITY CHART (PSF):L - MULLLENGTH(IN)W - TRIBUTARY WIDTH (IN)18.021.0 24.0 27.0 30.0 33.0 36.0 39.0 42.0 45.0 48.036.050.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.042.050.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.048.050.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.054.050.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.060.050.0 50.0 50.050.050.0 50.0 50.0 50.0 50.0 50.0 50.066.050.0 50.0 50.0 50.0 50.0 50.0 50.0 49.8 47.8 46.1 44.872.050.0 50.0 50.0 50.0 50.0 49.3 46.544.1 42.240.6 39.278.050.0 50.0 50.0 50.0 47.844.541.839.6 37.7 36.2 34.884.050.0 50.0 50.0 47.5 43.6 40.6 38.0 35.9 34.1 32.6 31.490.050.0 50.0 48.3 43.7 40.1 37.2 34.8 32.9 31.2 29.7 28.596.050.0 50.0 44.8 40.6 37.2 34.4 32.2 30.3 28.7 27.3 26.1SHEET:DWG. #:9AWD112 BUILDING DROPS, INC. 398 E. DANIA BEACH BLVD., STE. 338 DANIA BEACH, FL 33004 PH: (954)399-8478 FAX: (954)744.4738 WEB: www.buildingdrops.comOFSCALE:NTSSMDWG. BY:DATE:09.28.17CHK. BY:HFNREMARKSTITLE:BY DATETHE INSTALLATION DETAILS DESCRIBED HEREINARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONSFOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATIONTO DEVIATEFROM THE REQUIREMENTS DETAILED HEREIN, A LICENSEDENGINEER OR ARCHITECT SHALLPREPARE SITE SPECIFIC DOCUMENTS FOR USEWITH THIS DOCUMENT200 SERIES NARROLINE GLIDING PATIO DOOR (NON-HVHZ)(NON-IMPACT) 9/30/2020 12:08 PMs:\projects\andersen windows\cc-20-0224 - code change - fbc 2020 (version 7) code change\revisions\fl14429\dwgs\14429.2\awd112 200 series narroline gpd.dwg 10FL14429FL #:PREPARED BY:HERMES F. NORERO, P.E.FLORIDA P.E. No 73778BUILDING DROPS, INC398 E. DANIA BEACH BLVD. # 338DANIA BEACH, FL 33004FBPE CERT. OF AUTHORIZATION No. 29578100 FOURTH AVE NORTHBAYPORT, MN 55003-1096PH: (651) 264-5150 FX: (651) 264-54857TH FBC CODE CHANGE SR 3.18.20 SIDELITE MULLIONS 10THROUGH FRAME - TYP.EXTERIOR VIEWMULLION ANCHOR DETAIL - SILLB200 SERIES NLGPD STAT UNIT3" MIN. O.C.9" MAX.200 SERIES NLGPD PATIO DOOR10THROUGH FRAME - TYP.EXTERIOR VIEWMULLION ANCHOR DETAIL - HEADA3" MIN. O.C.9" MAX.3" MIN. O.C.9" MAX.3" MIN. O.C.9" MAX.THREE (3) INSTALLATION ANCHORSTHROUGH EA. FRAMESEE SHEET 1, INSTALLATION NOTES 4,5, OR 6 WHERE APPLICABLETHREE (3) INSTALLATION ANCHORSTHROUGH EA. FRAMESEE SHEET 1, INSTALLATION NOTES 4,5, OR 6 WHERE APPLICABLE200 SERIES NLGPD STAT UNIT200 SERIES NLGPD PATIO DOORSHEET:DWG. #:10AWD112 BUILDING DROPS, INC. 398 E. DANIA BEACH BLVD., STE. 338 DANIA BEACH, FL 33004 PH: (954)399-8478 FAX: (954)744.4738 WEB: www.buildingdrops.comOFSCALE:NTSSMDWG. BY:DATE:09.28.17CHK. BY:HFNREMARKSTITLE:BY DATETHE INSTALLATION DETAILS DESCRIBED HEREINARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONSFOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATIONTO DEVIATEFROM THE REQUIREMENTS DETAILED HEREIN, A LICENSEDENGINEER OR ARCHITECT SHALLPREPARE SITE SPECIFIC DOCUMENTS FOR USEWITH THIS DOCUMENT200 SERIES NARROLINE GLIDING PATIO DOOR (NON-HVHZ)(NON-IMPACT) 9/30/2020 12:08 PMs:\projects\andersen windows\cc-20-0224 - code change - fbc 2020 (version 7) code change\revisions\fl14429\dwgs\14429.2\awd112 200 series narroline gpd.dwg 10FL14429FL #:PREPARED BY:HERMES F. NORERO, P.E.FLORIDA P.E. No 73778BUILDING DROPS, INC398 E. DANIA BEACH BLVD. # 338DANIA BEACH, FL 33004FBPE CERT. OF AUTHORIZATION No. 29578100 FOURTH AVE NORTHBAYPORT, MN 55003-1096PH: (651) 264-5150 FX: (651) 264-54857TH FBC CODE CHANGE SR 3.18.20 MULLION ANCHOR DETAIL