Loading...
GAF Shingle Product Approval FL10124-R33 NEMO|etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT BY FLORIDA P.E. GAF 1 Campus Drive Parsippany, NJ 07054 (800) 766-3411 Evaluation Report 01506.01.08-R35 FL10124-R33 Date of Issuance: 01/03/2008 Revision 35: 12/16/2022 SCOPE: This Evaluation Report is issued under F.A.C. Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the prod uct under the Florida Building Code. The product described herein has been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles for use in FBC non-HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words “NEMO P.E. Evaluated” may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors a nd shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018 NEMO ETC, LLC NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.01.08-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL10124-R33 GAF Asphalt Roof Shingles Revision 35: 12/15/2022 BACK TO TOP Page 2 of 7 ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Product Approval Method: Method 1, Option D – Codified Material, Evaluation by Engineer Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4, R905.2.3 Material standard ASTM D1970 2015 1507.2.5, R905.2.4 Material standard ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2019 1507.2.7.1, R905.2.6.1 Wind Resistance TAS 107 2020 3. REFERENCES: ENTITY EXAMINATION REFERENCE DATE NEMO (TST6049) ASTM D1970 4j-GAF-22-SSUDL-02 08/08/2022 PRI (TST 5878) ASTM D3462 GAF-897-02-01 11/08/2018 PRI (TST 5878) ASTM D3462 GAF-898-02-01 11/08/2018 PRI (TST 5878) ASTM D3462 GAF-899-02-01 11/15/2018 PRI (TST 5878) ASTM D3462 (IN-MV) 376T0133 02/05/2021 PRI (TST 5878) ASTM D3462 (CA-S) 376T0135 02/05/2021 PRI (TST 5878) ASTM D3462 (IN-MV) 376T0163 04/20/2021 PRI (TST 5878) ASTM D3462 (IN-MV) 376T0293 03/22/2022 UL (TST 1740) ASTM D3462 93NK6295 11/29/1993 UL (TST 1740) TAS 107 94NK9632 03/29/2000 UL (TST 1740) ASTM D3161 04NK30546 03/10/2005 UL (TST 1740) ASTM D3462, D3161 04NK22009 05/06/2005 UL (TST 1740) ASTM D3161, D3462 06CA35251 10/18/2006 UL (TST 1740) ASTM D3462 06CA31603 12/01/2006 UL (TST 1740) ASTM D3161, D3462 06CA41095 12/27/2006 UL (TST 1740) ASTM D3161 06CA31611 04/04/2007 UL (TST 1740) ASTM D3161 06CA61148 04/09/2007 UL (TST 1740) ASTM D3161, D3462 07CA31742 11/08/2007 UL (TST 1740) ASTM D3161, D7158, D3462 08CA06100 03/13/2008 UL (TST 1740) ASTM D3161, D3462 09CA10592 03/26/2009 UL (TST 1740) ASTM D3161, D3462 09CA06856 05/15/2009 UL (TST 1740) ASTM D3161, D7158, D3462 09CA27281 08/27/2009 UL (TST 1740) ASTM D3161, D7158, D3462 10CA35554 03/05/2010 UL (TST 1740) ASTM D3161, D7158, D3462 10CA13686 05/15/2010 UL (TST 1740) ASTM D3462 10CA11953 10/29/2010 UL (TST 1740) ASTM D3161, D7158, D3462 10CA53934 03/31/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA48924 10/22/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA47919 12/03/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA48725 12/09/2011 UL, LLC. (TST 9628) ASTM D3462 12CA34891 10/12/2012 UL, LLC. (TST 9628) ASTM D3161 12CA38083 02/26/2013 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4786875675 07/27/2015 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4787434542 05/17/2016 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4788717529 09/09/2016 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4788198026 11/28/2017 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.01.08-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL10124-R33 GAF Asphalt Roof Shingles Revision 35: 12/15/2022 BACK TO TOP Page 3 of 7 ENTITY EXAMINATION REFERENCE DATE UL, LLC. (TST 9628) ASTM D3161 4788698165 11/09/2018 UL, LLC. (TST 9628) ASTM D3161 4788669132 12/13/2018 UL, LLC. (TST 9628) ASTM D3161 4788891098 02/14/2019 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4788932264 08/16/2019 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4789115488 10/03/2019 UL, LLC. (TST 9628) ASTM D3161, D3462 4788959558 10/17/2019 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4786508528 11/01/2019 UL, LLC. (TST 9628) ASTM D3161 4789132672 10/27/2020 UL, LLC. (TST 9628) ASTM D3161 4789732437 04/15/2021 UL, LLC. (TST 9628) ASTM D3462 4790002635 01/26/2022 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4788198026 05/23/2022 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4790488380 08/22/2022 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4790111695 08/30/2022 UL, LLC. (QUA 9625) Quality Control Service Confirmation 12/06/2022 UL, LLC. (QUA 9625) Quality Control Florida BCIS Current 4. PRODUCT DESCRIPTION: TABLE 1: ASPHALT SHINGLE COMPONENTS TYPE PRODUCT DESCRIPTION MATERIAL STANDARD PLANT(S) ACCESSORY STARTER STRIPS Pro-Start® Starter Strip Shingles starter strips for asphalt roof shingles ASTM D3462 CA-S, IN-MV QuickStart® Peel & Stick Starter Roll mineral-surfaced, fiberglass-reinforced, self- adhering SBS modified bitumen starter strip, nominal 9-inch x 33 ft roll, for use with asphalt shingles with exposure of 6-inch or less ASTM D1970 CA-S ACCESSORY STARTER STRIPS StarterMatch® Starter Strip Shingles color-coordinated starter strips for use with Grand Canyon® and Grand Sequoia® series asphalt shingles. StarterMatch® are installed as the second starter for Grand Canyon® and Grand Sequoia® series installations ASTM D3462 CA-F WeatherBlocker™ Premium Starter Strip Shingles starter strips for asphalt roof shingles ASTM D3462 IN-MV ASPHALT SHINGLES Marquis WeatherMax® fiberglass reinforced 3-tab asphalt roof shingles ASTM D3462 IN-MV Royal Sovereign® AL, CA-F, FL, GA, IN-MV, PA, TX-D Camelot® II fiberglass reinforced, laminated asphalt roof shingles ASTM D3462 IN-MV Fortitude® PA Glenwood® IN-MV Grand Canyon® CA-F, IN-MV Grand Sequoia® CA-F, IN-MV Grand Sequoia® AS CA-F Timberline® AH AL, CA-F, IN-MC, PA Timberline® AS II CA-F, CA-S, TX-E Timberline® CS CA-F Timberline HD® AL, CA-S, CA-F, FL, IN- MC, MD, MN, PA, TX-D, TX-E Timberline® Solar HD CA-F, CA-S, IN-MV Timberline HDZ® AL, CA-F, CA-S, FL, IN- MC, MD, MN, PA, TX-D, TX-E Timberline® UHDZ™ AL, CA-S, IN-MC, PA Timberline® Solar HDZ® IN-MV NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.01.08-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL10124-R33 GAF Asphalt Roof Shingles Revision 35: 12/15/2022 BACK TO TOP Page 4 of 7 TABLE 1 (CONTINUED): ASPHALT SHINGLE COMPONENTS TYPE PRODUCT DESCRIPTION MATERIAL STANDARD PLANT(S) ASPHALT SHINGLES Timberline® NS fiberglass reinforced, laminated asphalt roof shingles ASTM D3462 AL, CA-S, FL, IN-MC, MD, MN, PA, TX-D, TX-E Timberline Ultra HD® AL, CA-S, IN-MC, MN, PA, TX-E Timberline® UHD AL, CA-S, IN-MC, MN, PA, TX-E Woodland® IN-MV Slateline™ fiberglass reinforced 5-tab asphalt roof shingle ASTM D3462 IN-MV HIP & RIDGE SHINGLES Seal-A-Ridge® AS ArmorShield® SBS-Modified IR Ridge Cap Shingles fiberglass reinforced, hip and ridge asphalt roof shingles ASTM D3462 GA Seal-A-Ridge® Ridge Cap Shingles GA, IN-MV Timbertex® Premium Ridge Cap Shingles IN-MV 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications TABLE 2A: WIND CLASSIFICATIONS, ASPHALT SHINGLES PRODUCT FBC TABLE 1507.2.7.1 OR R905.2.6.1 Marquis WeatherMax® ASTM D3161(F) & ASTM D7158(H) Royal Sovereign® ASTM D3161(F) & ASTM D7158(H) Camelot® II ASTM D3161(F) & ASTM D7158(H) Fortitude® ASTM D3161(F) & ASTM D7158(H) Glenwood® ASTM D3161(F) & ASTM D7158(H) Grand Canyon® ASTM D3161(F) & ASTM D7158(H) Grand Sequoia® ASTM D3161(F) & ASTM D7158(H) Grand Sequoia® AS ASTM D3161(F) & ASTM D7158(H) Timberline® AH ASTM D3161(F) & ASTM D7158(H) Timberline® AS II ASTM D3161(F) & ASTM D7158(H) Timberline® CS ASTM D3161(F) & ASTM D7158(H) Timberline HD® ASTM D3161(F) & ASTM D7158(H) Timberline® Solar HD ASTM D3161(F) & ASTM D7158(H) Timberline HDZ® or Timberline® UHDZ™ ASTM D3161(F) & ASTM D7158(H) Timberline® Solar HDZ® ASTM D3161(F) & ASTM D7158(H) NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.01.08-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL10124-R33 GAF Asphalt Roof Shingles Revision 35: 12/15/2022 BACK TO TOP Page 5 of 7 TABLE 2A: WIND CLASSIFICATIONS, ASPHALT SHINGLES PRODUCT FBC TABLE 1507.2.7.1 OR R905.2.6.1 Timberline® NS ASTM D3161(F) & ASTM D7158(H) Timberline Ultra HD® ASTM D3161(F) & ASTM D7158(H) Timberline® UHD ASTM D3161(F) & ASTM D7158(H) Woodland® ASTM D3161(F) & ASTM D7158(H) Slateline™ ASTM D3161(F) & ASTM D7158(H) 5.5.1 Classification by ASTM D7158: ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. TABLE 2B: WIND CLASSIFICATIONS, STARTER STRIPS AND HIP & RIDGE TYPE PRODUCT FBC TABLE 1507.2.7.1 OR R905.2.6.1 STARTER STRIPS Pro-Start® Starter Strip Shingles ASTM D3161, Class F WeatherBlocker™ Premium Starter Strip Shingles ASTM D3161, Class F HIP & RIDGE SHINGLES Seal-A-Ridge® AS ArmorShield® SBS-Modified IR Ridge Cap Shingles ASTM D3161, Class F Seal-A-Ridge® Ridge Cap Shingles ASTM D3161, Class F Timbertex® Premium Ridge Cap Shingles ASTM D3161, Class F (sealant required, See Section 6) 5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. 6. INSTALLATION: 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer’s minimum requirements. 6.1.2 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per F.A.C. Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with manufacturer’s published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 GAF asphalt shingles are acceptable for use in reroof (tear-off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and GAF published installation instructions. 6.2 STARTER SHINGLES OR STARTER STRIP: 6.2.1 Installation of Pro-Start® Starter Strip Shingles, WeatherBlocker™ Premium Starter Strip Shingles and QuickStart® Peel & Stick Starter Roll shall comply with the GAF current published instructions. 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Camelot® II, Grand Canyon®, Grand Sequoia® and Woodland® require minimum five (5) nails per shingle. ➢ Slateline™ requires minimum six (6) nails per shingle. NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.01.08-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL10124-R33 GAF Asphalt Roof Shingles Revision 35: 12/15/2022 BACK TO TOP Page 6 of 7 6.3.2 The following depict nail-placement locations for GAF shingles designed with a ‘target nail zone’. Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the GAF for details. 6.3.2.1 Fortitude®, Timberline® AH, Timberline® AS II, Timberline® CS, Timberline® HDZ® and Timberline® UHDZ™; slopes 2:12 up to 21:12. 6.3.2.2 Fortitude®, Timberline® AH, Timberline® AS II, Timberline® CS, Timberline® HDZ® and Timberline® UHDZ™; slopes greater than 21:12 6.3.2.3 Timberline® Solar HDZ®; slopes 2:12 up to 21:12. 6.3.2.4 Timberline® Solar HDZ®; slopes greater than 21:12 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.01.08-R35 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) FL10124-R33 GAF Asphalt Roof Shingles Revision 35: 12/15/2022 BACK TO TOP Page 7 of 7 6.4 HIP & RIDGE SHINGLES: 6.4.1 Installation of Seal-A-Ridge® Ridge Cap Shingles shall comply with the GAF current published instructions with a minimum two (2) nails, minimum 3/8- inch head diameter located 6-7/8-inch back from the exposed end and 0.5- inch from the edge. 6.4.2 Installation of Seal-A-Ridge® AS ArmorShield® SBS-Modified IR Ridge Cap Shingles shall comply with the GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle located 5.25-inch back from the exposed end and 1-inch from the edge. 6.4.3 Installation of Timbertex® Premium Ridge Cap Shingles shall comply with GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Henkel “Loctite PL Roof & Flashing Polyurethane Sealant”. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY ASSURANCE ENTITY: UL (QUA9625): (360) 817-5512; bsai.inspections@ul.com - END OF EVALUATION REPORT -