Loading...
955 SAILFISH DR POOL23-0025 rst tJr, BUILDING PERMIT APPLICATION FOR INTERNAL OFFICE USE ONLY •" ' Cityof Atlantic Beach Building Department PERMIT I# cot_Z ` 00 • - 800 Seminole Road,Atlantic Beach, FL 32233 **ALL information required to process Phone: (904) 247-5826 Email: Building-Dept@coab.us Job Address 955 Sailfish Drive REP I 1125 1 - 0 Legal Description 30-60 17-2S-29E ROYAL PALMS UNIT I LOT 38 BLK 6 Valuation of Work(Replacement Cost) ji �i`7 ctiC Heated/Cooled SF Non-Heated/Cooled SF - Class of Work: ❑ New ❑Addition ❑Alteration ❑Repair ❑Move ❑Demo ®Pool ❑Window/Door - Use of existing/proposed structure(s): ❑Commercial vi Residential - If an existing structure,is a fire sprinkler system installed?: ❑Yes ❑No - Will tree(s)be removed in association with proposed project? ❑Yes(Must submit separate Tree Removal Permit) isiNo Describe in detail the type of work to be performed: New shotcrete swimming pool Florida Product Approval# (For multiple products use Product Approval Information Sheet) Property Owner Information Name Jorge Figueredo Phone Address 955 Sailfish Drive city Atlantic Beach State FL Zip 32233 Email firstclassturf@gmail.com Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company Sunshine Pool Services of North Florida,LLC Phone 904-318-8627 Address 318 Milwaukee Avenue City Orange Park State FL Zip 32224 Qualifying Agent Brent White State Certification/Registration# CPC1456759 Email kelli@ss-pools.com Job Site Contact Number 904-304-6908 - Worker's Compensation Insurer yes OR Exempt ❑ Expiration Date I j ► 2—o Z.14- Architect's Name Email Phone Engineer's Name Nicholas Eckardt,P.E. Email nick@allaquaticengineering.com Phone (904)451-0630 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES, BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such os water management districts,state agencies, or federal agencies. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER:YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMP'OVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN A TTO!''EY BEFO' _ ' 0 _ OTICE OF COMMENCEMENT. (Signa re of Owner or Agent) (Signature of Contractor) e- Signe• and sworn to(or affirmed)before me this i 5 day of Signed and sworn to(or affirmed)before me this I ( day of e1^��Vgf , ' •s b J r e • trerlo �{ �n-� JcJ , . • _ by_.. r'e-t- w Signature of Notary �l Signature of Notary - '• [ I Personally Know OR III Produced Identification personally Known OR [ I Produced Identification Type of Identification: VI, b Type of Identifi tr, nr, _ _ -- NidasalboarairdinahAllidhadbollime KELLI 8ROMMER HARGETT KELLI BROMMER HARGTf I f.= ��' Notary Public-State of Florida ( ` NotaryPublic-State of Florida �' ' Commission 4 HH 246003 I1 :a", `_ Commission#HH 246003 ark? My Comm.Expires Mar 28,2026 or M1 My Comm.Expires Mar 28, 2026 ( Borded through National Notary Assn. I Bonded through Natioral Notary Assn. COPING ONLY POOL/No Dec Ing P= Pool setbacks measured to waters edge i PE= Pool Equipment setbacks measured to furthest projection /\ \ Pool Certified alarms will be installed Silt fence will be installed 3 / \ -- Pool = 10'x 20' • / ,.4o Pool Depth=4' a` Sunshine Pools j / •c, ry Date T sp 8J30/23 / / 4-'4 . Zw< \'3344. o I / a fie oF / O^ L�` Y` iy ,Y ;i �Q v / 1, I Co / GI CO mx• c / Y m? \a • te \ Xi 0 � , . : - •\ � \ C 41,- / i 0 \ 4. ,' <3 4� �lik6 6 �� -c„-.7:, .,„c,_ ,...., ,, , ,.., 4 171- 0 v A. Erosion control such as silt fence shall be pia.: ' t;e limits of construction- f Lrat..°4(4,„0.---.....i.„_ \ ,E: i g ...., ` i5 activities and/or property line. S .1,?* e ;8 $s I. B. Excavated material shall be removed fro 1Yi site. ; C. Existing/Engineered drainage patterns sh6l1 d!h altered wit thori•4:•�: \ by the Engineer of Record or submission of a rev ngi$Bred a ) it v (signed and sealed). , V s?,. D.Drains will be directed away from adjacent lots. /P qb pi_Es S23.,....4",.�J �' E.The applicant/owner/contractor shall immediately contact Co bl{, ading .f3 417,--- ...5z �o ��� staff should modifications to the plan be required based on actual fie co ditions. 06"/� F. Retaining walls,roof gutters with underground drainage system may be required 2.3g� based on actual field conditions. ♦♦�� ` i G.Contractor shall be required to coordinate a lot grade inspection with County Staff prinr to p..rmit close nut and schedule a 904 inspection. Lot= 7,500 sf Building = 1,342 sf + Impervious = 714 sf + Proposed = 9sf(equipment pad only) = 27% COPING ONLY POOL/ in9 P. Pool setbacks measured to waters edge \ PE= Pool Equipment setbadcs measured to furthest projection / Pool Certified alarms will be installed 7 I` Slit fence will be installed I / ��\ � Pool = 10'x20' / ,\,o Pool Depth=4' Sunshine Pools i / ��• Date t R 8/30/23 i 4/ q 3 ' , / 611 7. S.; . ^ ,r4' s 4�' op / ,Zq!� $p / y0 i �° t„ 4. ( � ?P� \moo cn r,A 9 A r� 9-sem ' / `C SA" O f V P� / Y P.\ ...,, \ �c I it 41/4 d'ilt. -. • m i ., .. `\ lpz, c NI 6-- e ail 4s D G,,,„... .. 1 v at ''rJ A. Erosion control such as silt fence shall be pia• •c ';•-• .a limits of construction 8 `' P S5 activities and/or property lienee.removed fro w \ B.Excavated material shall tih�site. \ thori• C. Existing/Engineered drainage patterns sh!lA1,�o,�4 Itered o by the Engineer of Record or submission of a revTirgl red ' • • '1,, (signed and sealed). 034 wet; 10f S?szj. D. Drains will be directed away from adjacent lots. P 3,3,+>•w ,df�v E.The applicant/owner/contractor shall immediately contact Co RI{ ading �3 ?s i? staff should modifications to the plan be required based on actual fiat co ditions. by S�\.� o� F.Retaining walls,roof gutters with underground drainage system may be required 39. �� ��� based on actual field conditions. �. G.Contractor shall be required to coordinate a lot grade inspection with County Staff prinr to permit rinae_out and schedule a 904 inspection. \ Lot= 7,500 sf Building = 1,342 sf + Impervious = 714 sf + Proposed = 9sf(equipment pad only) = 27% POOL RECIRCULATION PUMP O Zodiac VSSHP270DV2a Nicholas W Eckhardt m m CMP Channel Drain 25506 W.F This item has been elecVonicafly IN (�,`p'.��,-5 signed and sealed by Nicholas W. L CU N » "'c=—�__ sO'..'••• 5 A Eckhardt,P.E.on the Date and/or u- rri I. 69144 S Time Stamp shown,using a = CI LL. ,a C. digital signature.Printed copies of c V l» „e'. STATE O Q; this item are not considered I.L = rt, °:9�...,c p:'rv'�,: signed and sealed and the m N f » ';`�- �QR��•'�� signature must be verified on any �+ Ln m i t h i i , I sS ONAL EN�'•'` electronic copy U n .'-, I » 2023.09.12 09:22:32-04'00' cu m c 1 » . .» •O m » L Q a gliiiiCN POOL RECIRCULATION FILTER j IIH E i 69144 4i.. + ! '� 4•'SS/ANAL EN�' a tx • — — Minimum pipe size and velocity ',1111 n "" Recirculation Pump' 9/12/2023 • Pool L 4' g 4' >2'•main drain suction @ 36 gpm-3.51 tt/s 11111111 ii. Area 212 sf >2"skimmer suction line @ 36 gpm-3.51 ft/s ALL AQUATIC Intl ..... >1.5"wall return lines @ 36 gpm=5.82 WS ENGINEERING Depth 4' 4 Volume 4,661 >2"vacuum line @ 36 gpm =3.51 Ws d� /A�y\`� Cs. CSCar!».FIG IW sa 7' ay. g CL (�\\✓ Y.A\aT ID... C.D....... Now F. I I. , Length 20' Vd Yd9 Rorie,ConMUU o1 CAM CS Camas.FA. 200Sp,I Width 10' it r Aaa.=4aPaa.,.2,D LAM LS G.vnw».14. 250 Sp II a, r»Olaa.IL vw2ua anonslake lsas Steps 3 land0E s 32.7 Skimmer 1 • — F la,am J Cleaner Line 1 ___ .s Wall Returns 3 g i 1,1`t5. iI Lights 1 z $- ; z z Channel Drain 1 - - - channel 2 s .t z 1 Equipment: R= 2'wall returns Pump 2.7 VS I."PIPE SIZES MINIMUM"LISTED MUST BE USED(MINIMUM SIZE),ANDJR L SIZES ARE DESIGNED TO NOT EXCEED THE FOLLOWING VELOCITIES: Filter cs 150 CL= 2"d--ner line `_ -8FT/S PRESSURE SIDE OF SYSTEM Chlorination Tablet Figueredo i -6 FT/S SUCTION SIDE OF SYSTEM • 2.REFER TO MANUFACTURER'S INSTRUCTIONS FOR PIPE SIZE Standard Time Clock 955 Sailfish Drive L=LED condu REQUIREMENTS AND CHANGE THE SIZE AS NEEDED,WHILE MEETING THE Atlantic Beach FL 32233 MINIMUM SIZES IN THE TABLE ABOVE. 3.ALL PIPING TO BE SCHEDULE 40 MINIMUM RATING UNLESS OTHERWISE E. NOTED. S= skimmer 4.POOL EQUIPMENT PIPING SIZE TO MATCH THE EQUIPMENT J L k' 0 2 CONNECTIONS,IN NO CASE SHALL THE EQUIPMENT PIPING TO BE LESS ' '' , THAN 2"PIPE SIZE. - 5.WALL AND FLOOR RECIRCULATION RETURNS,SPA JET LINES,AND E CLEANER UNES PENETRATIONS THROUGH THE POOL OR SPA STRUCTURE I SHALL BE 1.5"MINIMUM. 1.1 IZ) N 0 6.1"CONDUIT TO BE PROVIDED FOR ALL LIGHT LOCATIONS(NOT SHOWN �' J.I. IN SCHEMATIC),SEE THE ELECTRICAL SHEET FOR ADDITIONAL LIGHTING J 1-- •I ,J I S (/� 0 _ DESIGN INFORMATION. V • • lel SCNo REFERENCE CODE STANDARDS te SeptScale THESE DRAWINGS HAVE PEEN DESIGNED TO 6E IN ACCORDANCE WITH THE FOLLOWING CODES: Date ep2023 FLORIDA NUL DING CODE 7TH EDITION,RESIDENTIAL PRIVATE SWNAIING POOLS •20171MTION-NATIONAL ELECTRIC CODE Sheet SM-1 Na^,e 0 "CD m ANSI/APSP 58,7,2013 Specifies three methods for determining the maximum system flow rate. TDH Calculation Options ANSI/APSP/ICC Worksheet CU rn The following simplified TDH calculation is one of the methods specified. L tU r (For each Pump) Swimming Pool Energy Efficiency Compliance Information CD > rn Check one Note:These Requirements Apply ONLY to the Filtration Pump C:1 L.L. Simplified Total Dynamic Head(TDH)Calculation Worksheet r Simplified Total Dynamic Head(STDH) Maximum Filtration Flow Rate Calculations Complete STOH Worksheet-Fill in all Blanks '^ L Determine Maximum System Flow Rate v CI Total Dynamic Head ITDH) Pool Water Volume 4,661 /360=12.95 gpm=filtration flow rate U- co Minimum Flow Rate Required:35 gpm per skimmer(required:1 skimmer per 800 sq ft of surf.area) io v Complete Program or other tales.Fill in 4-a to c0 (gal./cubic 4,661 required blanks on worksheet&attached Is there an Auxiliary load on the filtration pump?Yes NO X l.) cr1 .� 1.Calculate Pool Volume 212 x 3 X 7.48 foot)= a) 'Err;Mae) Ix.a D.Plhl (VoLrne a,Gaacm) calculations �/ cC 0 Maximum Flow Capacity If so,what is the auxiliary flow rate 0 gpm ••0 �fOo 2.Determine preferred Turnover Time In Hours: 6 X60(min/hour)= 360 of the new or replacement pump Memel (turnover al On) P cement um L Q (use 36) Maximum Flow Rate 36 gpm(maximum auxiliary pool a 3.Determine Max Flow Rate 4,661 / 360 = 12.95 + 0 = 36 (vwm.mGallons) iturnovef in Mini (RecncFknv) (Feat.crow) (TaYFk,nRe.) Notes: loads or the filtration flow rate,whichever is greater.) ••••• 1.If a variable speed pump is used,use the max Thepool filtration flow rate shall not begreater than the rate !, W 4.Spa Jets: 0 X 0 GPM per jet= 0 flow rate um flow In calculations. yt' y\oENaa ' (no of JCS) (Jet Flow) aemJN Flow Rate, pump needed to turn over the pool water volume in 6 hours or 36 gpm 2.For side wall drains,use appropriate side wall whichever is greater.This means that for pools of less than • 59 � (For Singe Fawn poo;spa combo,use me higher of Bo.3 or No.a m the following ca'a i,tions for the cool&Spa) drain flow as published by manufacturer. 13,000 gallons,the pump shall be sized to have a flow rate of 36 STATE' Determine Pipe Sizes: 3.Insert manufacturer's name and approved gpm or less. '`, H',� x'gS 4pa1G•'s maximum flow. SrpNALE" Branch Piping to be 2 inch to keep velocity @ 6 fps max.at 36 gpm mak mum System Flow Cate 4.See installation instructions for number of Suction Pipe Size @ 6 fps 2 inch ports to be used. 9/12/2023 Suction Piping to be 2 inch to keep velocity @ 8 fps max.at 36 gpm Maximum System Flow Rate 5.In-Floor suction outlet cover/grate must Return pipe size @ 8 fps 1.b inch Return Piping to be 1.5 inch to keep velocity @ 10 fps max.at 36 gom Maximum System Fiow Rate conform to most recent edition of ASME/ANSI Filter Factors:(Cartridge.375)or(DE 2)or(Sand 15) ALL AQUATIC 4112.19.8 and be embossed with that edition ENGINEERING Determine Simplified TDH: approval. 36 / .375 = 96 'L 6.Pump,Filter,and Heater make and model (now rate) (filter factor) (minimum fixer sire) /r �j(� E � 1.Distance from pool,to pump in Ft: 45 cannot change,and equipment location cannot rlwH,amnrn.or be moved closer to the pool without submitting Filter Make/Size .randy Zodiac CS150 Cartridge,150SF Avmom,n<.raen. 2.Friction loss(in suction pipe)in 2 inch pipe per 1 ft.@ gpm= .06 (from pipe now/friction loss chart) a revised plan and TDH calculation worksheet for Ma Land 0 iia 0'LakerLswse31z approval. Backwash valve?Yes_No X (If yes,must be 2 Inch min) ,uam,ranee...=am 3.Friction loss(in return pipe)In 1.5 inch pipe per 1 ft.@ gpm= .14 (from pipe now/friction loss chart) m 4. 66 _ Pump Seiction from APSP database on Curve A(Less than 17000 J 559 50g uemn msmn. x .06 3.96 gallons)or C(greater than 17,000 gallons)(circle one) 8 • IP,e j E i Merl (Rol Hea0M of DSP) Mal Solon Reel W yy a 5, 108 X .14 = 15.12 Model7odac VSSHP270DV?A 8. s 5 R n 1 ' MVO Or MNm Re.)' (Ft aH.+arh or ON) (UM Raton,Nal Tow Wan In Cameroon crwr h 1 TDH in Piping 19.08 Flow Rate(low speed) 36 gpm @ 2400 rpm •• " Flow and Friction Loss Per Foot Filter loss in TDH(from filter data sheet) 2 N ♦ ti (Schedule 40 pvc Pipe) Heater loss in TDH(from heater data sheet) 5 r no or ,.N ar. Total all other losses 2 Flow Rate(high speed) 36 gpm @ 2400 rpm ,®mO�t9. 1 e • ••a Velocity-Feet Per Second (not required if no auxiliary load on filtration pump) ,• ; w Pipe Size 6 FPS 8 FPS 10 FPS Total Dynamic Head TDH 28.08 e•© 1.5" 37gpm .08' 50 gpm .14' 62gpm .21' Pump Controls ./.,MI 7ll=f , ••• I �A,Y R. M oak.: 2" 62 gpm 06 82 gpm 10' 103 gym .16' Standard time clock/2 speed time clock or other X mit-vial.,'.., 2.5" 88 gpm .05' 117 gpm .08' 148 gpm .13' Date •' :. :" ' 3" 136 gpm.04' 181 gpm .07' 227 gpm 10' 4" 234 gpm.03' 313 gym .05' 392 gpm 07' Heater Model None ,• 6" 534 gpm.02' 712 gym 03' Notes:suction piping in front of pump inlet must be 4 pipe ;. . ; til diameters in length.Must have 18"straight pipe after the filter ' . • - Selected Pump and Main Drain Cover: Signature • Ye nt n ' T-a Contractors for solar. - -r a) Pump selection Zodiac VSSHP270DV2A using pump curve for TDH&System Flow Rate = - (Pump model and she in HP) . «• Main Drain Cover CUP Channel (system Flow Rate-oil not exceed approved cover now rates) Print Name N INFORMATION'&.STATEMENT: ,• ••.- •••U•f^_ C) Y THIS SHEET HAS BEEN COMPLETED BY )- t v (model) ENGINEER AND IS BASED ON THE DRAWINGS PROVIDED BY t.__-id R "ea or ne we-A• .� Notes:Minimum system flow based on minimum flow per skimmer of 35 gpm. THE BUILDER,ENGINEER HAS VERIFIED THE SIMPLE TOTAL e•••e to Certification Number DYNAMIC HEAD CALCULATIONS SHOWN THIS SHEET WITH ., -' •� Determine the Number and Type of Required In-Floor Suction Outlets: ENGINEER'S POOL CALCULATION PROGRAM.ENGINEER'S "•5 .'� CALCULATIONS COVER THE POOL RECIRCULATION,SPA JET ;,•1 t" (Checx all that apply)I FLOW,AND:OR FEATURE FLOWS,FOR SINGLE OR MULTIPLE i }r •.+- tics e No Scale 0 0.0- 3' -10 Suction Outlets @ gpm max.flow(see note) Telephone Number PUMP SYSTEMS.EACH PROJECT IS ENGINEERED SPECIFIC TO e• - 'rte-= "' ]ate Sept 2023 ❑0 0 0 Suction Outlets @ gpm max,flow(see note 31 THE POOL SHOWN, •non ree,wTCrn W4 inf V OE l-All:°iin rrtuoe,area Crs�t �I 1 32- Channel Drain @ 144 gpm w/ 2' ports(see note4) Gaceateso`WrneonnIN a Of MAI s..t JM-2 a-e 0 -a m Q) ry >`. 0) N (] LL J DECK(PAVER POOL BEAM THICKNESS P - v OR CONCRETE) B" �..1_ w I MO TYPICAL POOL WATERLINE as O1 MOW GSM b COPING >I y I Lail m 111=1111 ` 4) m c I'III I� (2)A 3CONT.BOND BEAM 'Oco _11 p� - Q _ �� •3REBAR @12"OC Cl.. EACH WAY CONTINUOUS N POOL SHELL L- W e r 8 QENyr� CONCRETE MIN.POOL WALL �yy� Es1fAII POOL SHELL THICKNESS g Y` ua TA/ 4 y STATE We( MN.POOL ?b'..<t RODP- 4 FLOOR \'?SS/ONAt N?. THICKNESS "' N 2F-NERAL STRUCTURAL NOTATION' 9/12/2023 >REBAR SIZING AS SNOINN HEREIN a RERAR ASTM ASIS GRADE 60 >CONCRETE COVERAGE M REINFORCEMENT fa -T IN FOOTINGS ALL AQUATIC -T IN ALL OTHERS ENGINEERING a IK PSI PUMP GRADE CONCRETE READY MIX POOL WALL/FLOOR SECTION a MAX ENDS LAPPED 010 GAR DIAMETERS 12..c 1.. Mak,UrtMan of Araawnon 01100 7M1IAn<O L,h..Aao.0311 Laa 0 Nhn,FL SIMA AMyutQnp,wino.00a g 1i1g• . DECK(PAVE ;� N i q! OR CONCRETE)) WATERLINE Doma POOL BEAM THICKNESS B (2)N 3 CONT.BOND BEAM ` 1 • .111 TOP TOP STEP VARIES(SEE PLAN) • B„ 4,41� WATERLINE I 1 = MIN. IIIE 2 D ,,„.g o 1•0 m REBAR PLACEMENT z iSAME AS POOL WALL (IYP) FLOOR SECTION , E �j 6 4–STEP HEIGHTS b POOL �� TO BE UNIFORM 4_, RI STRUCTURE - L MI b. D3REBAR @12' 4_,- OC EACH WAY U ++ CONTINUOUS IN c C) M 6. 0 o. — POOL SHELL -C N BENCH SECTION STAIRS SECTION sr.„ 1/2"=1" 1/2•m r 1,2 =r• :)IIL, Sept 2023 s"'etSM-3 VSFWP't$SL1v (New Pump Model) rn S� C v. erle% 'Must purchase a JEP-R or IgPump01 If there is not automation 'No need for a timeclock for Balt(built In auxiliary) "Dual Volta80 115(230 fir. t 'vr yr a t y t.i .k''" n�av Y`n'" r'"y` �n � VS FloPro 1.85 HP Variable-Speed Pump,115/230 VAC, 2 Aux Relays,w/o Controllero • *' - �� ?'� �'rMrr: „, ` `'� sqrk � ° .• V5FHP1I6DV2A Partormanca Curv.s Features & Benefits YS , _��� ��� � "T 1450 RPt.1 xa J X �1r i t AC4i n Y i "m s i rit yv • 115/230 VAC ,,,. � " ��'41-111^.`7,:' �wK , ' ■ Medium Head Pum ':- n k p t 3000 RPM • Two Auxiliary Relays • Dry Contact Relay Control for old automation compatibility • The pump will not de-rate at 3450 RPMS. This allows to the z 10o RPM to move the same amount &water at 115V/230V a 1730 RPM 1200 RPM10 600 RPM _` n 0 1,1 23 3) :) 5:v CO 70 EO 90 134 110 129 1N WO Flow Rata,Gallons Par Minute(GPM) CMP 32 " CHANNE .�V�B �-t DRAINS VGB-2008 CMP#25506-32X-000* - COMPUAi'VT A. Read and keep these instructions for future reference. Always Plumb and instal ail suction fittings according to all building codes that apply in your area. WARNING:When using two or more suction fittings on a common suction line,sutons must be separated by a minimum of 3 ft or they must be located on two different planes(i.e.,one on floor and one on the wall). WARNING:DO NOT locate suction outlets on seating areas or on backrests for such seetino areas. The maximum flow rating for this suction fitting with the center port plugged and outer ports open is 308 GPM(Floor)and 212 GPM (Wall)when using 2.5`plumbing and 268 GPM(Floor)and 192 GPM(Wall)when using 2;plumbing. The maximum flow rating for this suction fitting with the outer ports plugged and the center port open is 200 GPM(Floor)and 168 GPM(Wall)when using 2.5' plumbing and 184 GPM(Floor)and 176 GPM(Wall)when using 2"plumbing. This suction fitting is designed for installation on side wail or floor of hot tubs or pools. DO NOT adapt suction fitting to any pipe se smaller than ASTM 2-SCH 40 PVC. Suction fitting and fasteners should be observed for damage or tampering before each use. Missing,broken,or cracked suction fittings shall be replaced before a""" mor"" `":`�+a .,717---- use.Loose suction fittings shall be reattached or replaced before use. I 'sceS^. ° ltSD "ai Mount suction fittings on the walls,in the foot wells of hot tubs or �� , to pools. Do not mount directly under seats. Follow all winterizing ----au D --- -1 � eZV instructions and recommendations of your pool and spa professional. on.a. n.,: Open area of the suction cover is 38.79 in'. .,,,,u,,,,. �� _ it Tools Needed Phillips Head Screwdriver „ ,,._,. a.1 �v . 1.50.ra. . .$D+.=..3 INSTALLATION INSTRUCTIONS Ivo — - '�!_ t Install sump provided or construct sump per i1 i lig ANSi/APSP-16 Figure 2(see below) " o 2. If mounting frame is provided,secure it in concretes ` GEIEOLLor plaster 4 r..Mich..m.0.a pba. 3. Use mountingscrews to secure cover to frame or sump. "a"'a� '°a~""""`�� P w aaa+wr.rL.�maaca.�Ww MISIFOOOT Head Loss NOTE In the event that one suction outlet is completely (ria x 10') *F�gr agsa��. m+.x blocked,the remaining suction outlets)serving that system 40 MUST have a flow rating capable of the full flow of the pump(s) for the specific suction system. NOTE Increasing size of the pimp may increase flow rate of 20 suction beyond rated safety limits causing entrapment or death. CAUTION:Hair or body parts blocking the spa or pool suctions a so i60 240 320 may become trapped and he'd against the suction fitting. Flow(GPM) Entrapment against the suction fittings can result in drowning or other severe injury. Never sit on or lean up against suction fittings.Never exceed the maximum allowable flow rate stated REPLACEMENT PARTS Rotate at pars annin on the suction Siting. The suction fitting and fasteners should 25506-32X-000 25506-32X-100 7 installed yews or be inspected for damage or tampering before each use of the immediately apo„ facility. Missing broken,or cracked suction fittings shall be Cover 25506-32X-020 Cover 25506-32X-02D e;�„� degradation replaced before using this facility. Loose suction fittings shall be ll 320-010 Frame 25506-320-110 or damage reattached or replaced before use of this facility. Plug 25520-050-020 Screw 61008.042-022 Screw 61008-042-022 *X CAN BE ANY DIGIT 0-9 TO Optional Debris Guard Optional Frame Support DENOTE COLOR 25506-320-030 25520-050-120 WARNINBC To reduce the risk of drowning from hair and body entrapment;install suction fittings with a marled flow rate in gallons per minute that exceeds the flow rate of your system by at least 25%. Always use multiple suction outlets. tf the fitting/cover breaks,s damaged,or is missing.shut the system down immediately. Do not use the system until damaged parts haw been replaced. WARN1/4Ge Keep hair and clothing a minimum of 12 Inches from alt suction fittings and drains at ail times.Parsons with tong hair should secure hair to a minimal length or wear swimming cap. Children should rimer be left unattended at any time In a swimming pool,spa,or bathtub. Be sure the temperature of the water never exceeds the rtlanufacturer's rammmandaticns. °"cid, CUSTOM MOLDED PRODUCTS 136 HERRING ROAD, NEWNAN, GA 30265 I WWW.0-M-PCOM Technicalpeccsirandve fsiceraieFilters c - -I1II1. j'\T® Pro series byzoDLAc& 611 X i4'/,` 0 1460010.." _ —MI WO II 1111111111111 ii 1.11 18'/` • .., 1 �,� V Part No. Description Size Specifications and Dimensions,CS Series Filters CS10O CS Cartridge Filter 100 Sq. Ft. Model No. CS100 CS150 cs200 CS250 Filter Area 10o ft2 150 ft2 200 ft2 250 ft2 CS150 CS Cartridge Filter 150 Sq. Ft. Design Flow Rate 1 gpm/ft2 .85 gpm/ft2 .625 gpm/ft2 .5 gpm/ft2 CS200 CS Cartridge Filter 200 Sq. Ft. Maximum Flow 100 gpm 125 gpm 125 gpm 125 gpm CS250 CS Cartridge Filter 250 Sq. Ft. Six(6)Hour 36,000 45,000 gal- 45,000 45,000 gal- Capacity gallons Ions gallons Ions CS Filter Head Loss Curves Eight(8)Hour 48,000 60,000 gal- 60,000 60,000 gal- Ca ac' I p rtY gallons Ions gallons Ions Normal Start Up 1 Pressure 6-15 psi 6-15 psi 6-15 psi 6-15 psi 8. _ 3 Max.Working Pressure 6 50 psi 50 psi 50 psi 50 psi Design Head �` Design Cartridges Loss / Pressure Required 1 1 1 1 Drop (ft head) 4 / —2 (Psi) Shipping Weight 28 lbs. 28 lbs. 34 lbs. 36 lbs. Height('A') 32W 32W 42W' 421,4 2 1 - — 1 I I 0 I ; . 0 0 30 60 90 120 - CS150 Now Rate(gpm) — CS200 — CS250 CS100 www.ZodiacPoolSystems.corn 02011 Zodiac Pool Systems,Inc.SA6259 0611 "f ZODIAC°is a registered trademark of Zodiac International,S.A.S.U., used under license. T- r ifGMEIQt1T�C;LIS lath'?OnLrU.F.DFRJn� a , WARNING }. Read Before pOOIguard t � �:� ;f_ You Buy W�k 101460111%.101111110100"ftiON ._ Poolguard Alarms: INGROUND POOL ALARM -MODEL PGRM-2 •Pool Alarm—Model PGRM-2 •Pool Alarm—Model PGRM-SB •Gate Alarm Door Alarms -NEW ( `NSF Certified to ASTM F 2208-08" •Door Alarm-DAPT-2 (Sounds in 7 seconds) •Door Alarm-DAPT WT CI-(Sounds immediately) Model PGRM-2 Installation Video 1.-_ Other Information: � l.,1!�',' i rti •Contact Us ,. # <9 •Buy Poolguard ti F. . •Product Manuals °`" �, •News From Pool card1-;:' j ( t`t 1t Si I .4 •Warranty Registration µ { •Model PGRM-2 Installation Video "' i k As Well As the states of CA, •Model PGRM-SB Installation Video CT, FL,and TN .,.. _ t •Detects Intruders •Sits on Deck °y�f _ E .- � `, ,, •Battery Powered 1.1r •Low Battery Indicator !i ill P •New Sensing Technology ` # •Easy to Use r .,-.,--,7:--,i47:-.,..,..: = ; •Completely Portable - z•----- -••''''''-2'- 3... '^:'',� - } •Automatic Reset •Affordable Price •Important Safety Feature •In House Remote Receiver •Horns are 85 dB at 10 feet 14.''� POOLGUARD/PBM INDUSTRIES, INC.has - been manufacturing pool alarms,door alarms, r ,-- - and gate alarms since 3982 All Poolguard products are proudly Made in the USA. Poolguard Pool Alarms were tested and'Top • .,1.-3.4)?. Rated"by Good Housekeeping Magazine. s .` 1 _ Poolguard Pool Alarms have been Tested and � ; Certified by NSF International to the ASTM f r ,.,.�µ., Standard Safety Specification for Residential `- Pool Alarms.ASTM F 2208-08. , N ;.7.,,f R,J • POOLGUARD IN GROUND POOL ALARM NSF CERTIFIED TO ASTM F 2208-08 NEW Weatherproof Design NEW Sensing Technology NEW Microprocessor Technology 3 Year Warranty • The Poolguard POOL ALARM, once installed in the pool, cannot be de- activated; it is always in the alarm ready mode. • Tamper Proof:Poolguard POOL ALARM will sound an alarm when removed from the pool. • Sleep mode:when you would like to use your pool, simply remove the alarm from the pool and put it into sleep mode. • Automatic Wake-up: The Poolguard Pool Alarm will automatically wake up and run a system test when installed into the pool. • The Poolguard Pool Alarm comes with an in-house remote receiver that has a range up to 200 ft., and comes with a 12 volt power supply. • The Poolguard poolside alarm works on a 9-volt battery(not included); with a battery life of approximately one year. • Audible low battery indicator at the poolside alarm is also indicated by the in house remote receiver. • New sensing technology provides less chance of false alarms due to wind, rain or small objects such as sticks or toys entering the water. • Poolguard Pool Alarms have been tested and comply to the ASTM Standard Specification for Pool Alarms ASTM F2205, in a 16'x 32'pool. Poolguard Alarms can be used in pools up to 20'x 40'or 800 square feet. • The Poolguard Pool Alarm can be used with a solar blanket. • Most reliable, advanced,and affordable alarm available. • Poolguard PGRM-2 is designed to detect intrusions similar to a one year old child Inground Pool Alarm PDF manual All Products Proudly • E 4p,) QE"lT11ECALL TOLL-FREE 0 POOL RECIRCULATION PUMP Nicholas W Eckhardt r'^ Zodiac VSSHP2700V2A M �» CMP Channel Drain 25506 W.E This item has been electronically a) NI EN C:''"W�s, signed and sealed by Nicholas W. L N ;�' ...'s=O S �: Eckhardt,P.E.on the Date and/or 0) . » 69144 `• ' Time Stamp shown,using a = M u_ N _ , I ---_._ - digital signature.Printed copies of t� -c, r q TE pP this Item are not considered _ u »-� s•.O�` �� signed and sealed and theme ami s 0`.!oL Op:`�Tz f» v.T I 1 I i I ,`�,,,NAL ENG`? electronre must ic copy be verified on any +-+ to m U Ln .L_' I 2023.09.12 09:22:32.04'00' CU m c i me RAF Cie. .,..,..-...... 10EN3 POOL RECIRCULATION FILTEIf.R F OIr1YrLr.ww. IIE ..__..__._. R ,�... STATE :: 07 T It ;_: Minimum pipe size and velocity ss!oNAL ENG," Recirculation Pump• 9/12/2023 . .. •. • Pool L 4' N 4' >2"main drain suction @ 36 gpm=3.51 ft/s Area 212 Sf >2"skimmer suction line @ 36 gpm-3.51 ft/s ALL AQUATIC F.�1 ,mow =IF:. >1.5"wall return lines @ 36 gpm=5.82 ft/s ENGINEERING Depth 4' 4 20 ► >2"vacuum Ilne @ 36 gpm =3.51 ft/s Volume 4,661 g L L1 U , '.�" Len th 20' C L1 Udo c cs CreFleR NBA 1w 42 Ft 1. 18_, g Flond+c•mmuna CSc.N„PRN.., saF, Width 10' AWa R Nn Nd62W Tux Land a Lakes Aro.N an csno csCaw.F. 2EDSy.H ,rill._...:. Steps 3 ------ LendGINNf•FLlY311 AMA..dow,».mamm ir Skimmer 1 g Cleaner Line 1 1p Wall Returns 3 a • IAF s a Lights 1 i9. ,�� s E Channel Drain 1 •D= 3"channel z " Equipment: R= 2'wall returns g 4. Pump 2.7 VS 1."PIPE SIZES MINIMUM"LISTED MUST BE USED(MINIMUM SIZE),AND /. EF I P L SIZES ARE DESIGNED TO NOT EXCEED THE FOLLOWING VELOCITIES: Filter cs 150 CL= 2 dner line - _ -8FT/5 PRESSURE SIDE OF SYSTEM Chlorination Tablet Figueredo , n D -6 FT/5 SUCTION SIDE OF SYSTEM 2.REFER TO MANUFACTURER'S INSTRUCTIONS FOR PIPE SIZE Standard Time Clock 955 Sailfish Drive L=LED condu REQUIREMENTS AND CHANGE THE SIZE AS NEEDED,WHILE MEETING THE Atlantic Beach FL 32233 MINIMUM SIZES IN THE TABLE ABOVE. 3.ALL PIPING TO BE SCHEDULE 40 MINIMUM RATING UNLESS OTHERWISE _ E� NOTED. skimmer14.,p Qu Q 4.POOL EQUIPMENT PIPING SIZE TO MATCH THE EQUIPMENT G Q CONNECTIONS,IN NO CASE SHALL THE EQUIPMENT PIPING TO BE LESS q 0. .6+ THAN 2"PIPE SIZE. i— COC S.WALL AND FLOOR RECIRCULATION RETURNS,SPA JET LINES,AND t. 4-+ L E CLEANER ONES PENETRATIONS THROUGH THE POOL OR SPA STRUCTURE O cida L SHALL BE 1.5"MINIMUM. I Q7 C 6.1"CONDUIT TO BE PROVIDED FOR ALL LIGHT LOCATIONS(NOT SHOWN ____ '.. J -v C ' IN SCHEMATIC),SEE THE ELECTRICAL SHEET FOR ADDITIONAL LIGHTING �_-- ' L- 1 I - J N 0 _� DESIGN INFORMATION. sr.-,E No Scale REVERENCE COOE/SOS: -- Uate Sept 2023 THESE DR AWINOS HAVEAVE BEEBEEN DESIGNED TO BE IN ACCORDANCE WTTH THE FOLLOWING copes, P •FLORIDA BUILDING CODE TLE EDITION,RESIDENTIAL PRIVATE SWIMMINGPOOLS %a",e SM-1 •2017 EDITION-NATIONAL ELECTRIC CODE Aa,e 0 -0 rn ANSI/APSP 5&7,2013 Specifies three methods for determining the maximum system flow rate. TDH Calculation Options ANSI/APSP/ICC Worksheet ty n' The following simplified TDH calculation is one of the methods specified. >` v N(For each Pump) Swimming Pool Energy Efficiency Compliance Information > m Check one Note:These Requirements Apply ONLY to the Filtration Pump = 0 LL Simplified Total Dynamic Head(TDH)Calculation Worksheet l Simplified Total Dynamic Head(STDH) Maximum Filtration Flow Rate Calculations Complete STDH Worksheet-Fill in all Blanks L Determine Maximum System Flow Rate « u ❑ Total Dynamic Head(TDH) Pool Water Volume 4,661 /360=12.95 gpm=filtration flow rate L.L. m Minimum Flow Rate Required:35 gpm per skimmer(required:1 skimmer per 800 sq ft of surf.area) - v Complete Program or other talcs.Fill in co 1.Calculate Pool Volume 212 X 3 X 7.48(gal./cubic foot)= 4,661 required blanks on worksheet&attached Is there an Auxiliary load on the filtration pump?Yes_NO X U Ln .`_2 calculationsLaj (surface nasal (Avg NON twowm•�a oaaoasl CU C 360 ❑ Maximum Flow Capacity If so,what is the auxiliary flow rate 0 gpm .0 r-° 2.Determine preferred Turnover Time In Hours: 6 X60(min/hour)= of the new or replacementpump Q Moura) eumovor In vkn um 3.Determine Max Flow Rate 4.661 / 360 = Maximum Flow Rate 36gpm(maximumpool (use 36) 12.95 + 0 = 36 ( auxiliary (VowminGalan') u"movermlen) Ieacvc Flow) (goatee Flow) (total Flow note) Notes: loads or the filtration flow rate,whichever is nater. 4.5 a Jets: 5 01.If a variable speed pump is used,use the max The pool filtration flow rate shall not be greater than the rate P 0GPM perJet= 0 flow rate um flow In calculations. ceNs :'@�•': Ina of Jets) (let Flaw) (Tata(Jot Flo"'Rata' pump ons. needed to turn over the pool water volume in 6 hours or 36 gpm j/ F 2.For side wall drains,use appropriate side wall whichever is greater.This means that for pools of less thanf aatN (For Single Pump pool/spa combo,use the higher of No.3 or No.4 in the following calculations for the pool&Spa) drain flow as published by manufacturer. 13,000 gallons,the pump shall be sized to have a flow rate of 36 `Y' 4" STATE Determine Pipe Sizes: 3.Insert manufacturer's name and approved gpm or less. ''b',x'{QRuA, maximum flow. ypNA`ENc,' Branch Piping to be 2 inch to keep velocity @ 6 fps max.at 36 gpm Maximum System Flow Rate 4.See installation instructions for number of Suction Pipe size @ 6 fps 2 inch • Suction Piping to be 2 inch to keep velorty @ 8 fps max.at 36 gpm Maximum System Flow Rate ports to be used. 9/12/2023 5.In-Floor suction outlet cover/grate must Return pipe size @ B fps 1.5 inch Return Piping to be 1.5 inch to keep velalty @ 10 fps max.at 36 gpm Maximum System Flow Rate conform to most recent edition of ASME/ANSI Filter Factors:(Cartridge.375)or(DE 2)or(Sand 15) ALL AQUATIC A112.19.8 and be embossed with that edition �1�ENG,INEERIN�G��°° Determine Simplified TON: .approval.um36 / 375 = 96 G✓ .16✓ W a 6.Pump,Filter,and Heater make and model (now rare) (filter factor) (minimum filter site) 1.Distance from pool,to pump in Ft 45 cannot change,and equipment location cannot be moved closer to the pool without submitting Filter Make/Size Jandy Zodiac CS150 Canndga.15DSF Auaori`o'nMEDD i� 2.Friction loss(in suction pipe)In 2 inch pipe per 1 ft.@ gpm= .06 (from pipe flow/friction loss chart) a revised plan and TDH calculation worksheet for eazn,aa Lazes r.a.Is 327 Land O Lakes.ft 1.639 3.Friction loss(in return approval. Backwash valve?Yes No X (If yes,must be 2 inch min) auRuannakuwaoaa.mn, pipe)In 1.5 inch pipe per 1 ft.@ gpm= .14 (from pipe flow/friction loss chart) 4. 66 X .06 = 3.96 Pump Seiction from APSP database on Curve A(Less than 17000 0 ,a y (Ivor of...Pipe( (Ft ofxeod/h of Woe) ITOr Suwon Roel gallons)or C(greater than 17,000 gallons)(circle one) ft..4 Iii O a' 5. 108 X .14 = 15.12 w ast S Leve Model Zodiac VSSHP2700V2A ? g. a ei ( n,of Roo,Pool On or mold/rt or Pool (TON Mourn hovl w F. coav«.Imcrud w z 'N �i 44R TDH in Piping 19.08 Total Flow and Friction Loss Per Foot Filter loss in TDH(from filter data sheet) 2 Flow Rate(low speed) 36 gpm @ 2400 rpm N s (Schedule ao pvc Pipe) Heater loss in TDH(from heater data sheet) 5 '_'.» )• O Flow Rate(high speed) 36 gpm @ 2400 rpm u „ • Total all other losses 2 P .r o Velocity-Feet Per Second (not required if no auxiliary load on filtration pump) "'m '" g Pipe Size 6 Fps B FPS 10 FPS Total Dynamic Head(TDH) 28.08 + 1.5" 37 gpm .08' Sogpm .14' 62 gpm .21' `•�� � �:- Fes( , Pump Controls +e O �+. ) "• t • 2" 67 gpm .06' 82 gpm 10' 103 gpm .16' 2.5" 88 gpm .05' 117 gpm .08' 148 gpm .13' Standard time clock/2 speed time clock or other x ,. 3" 136 gpm.04' 181 gpm 07' 227 gpm .10' Date " 4" 234 gpm.03' 313 gpm .05' 392 gpm .07' Heater Model None _ 4. 6" 534 gpm 02' 712 gpm .03' Notes:suction piping in front of pump inlet must be 4 pipe in diameters in length.Must have 18"straight pipe after the filter 4:44: 'f- is it- � ,,„ 4,, Selected Pump and Main Drain Cover: Contractors Signature for solar. a :t # 4-' y Pump selection Zodiac VSSHP27o0V2A using pump curve for TDH&System Flow Rate 7 rW 7" 7.1e I . F- = L (Pump model and size In HP) 1 4-, 0 N Main Drain Cover_ CMP Channel (System Flow Rate must not exceed approved cover Row rates) Print Name EN4INEER'S STATEMENT Q1 ,6[ INFORMATION THIS SHEET HAS BEEN COMPLETED BY !" v >_ (model) ENGINEER AND IS BASED ON THE DRAWINGS PROVIDED BY t 0 Notes:Minimum system flow based on minimum flow per skimmer of 35 gpm. THE BUILDER.ENGINEER HAS VERIFIED THE SIMPLE TOTAL ,s a-•1, t/) Certification Number DYNAMIC HEAD CALCULATIONS SHOWN THIS SHEET WITH :41 't • Determine the Number and Type of Required In-Floor Suction Outlets: ENGINEER'S POOL CALCULATION PROGRAM.ENGINEER'S y. '.y+ (Check all that apply) CALCULATIONS COVER THE POOL RECIRCULATION,SPA JET L FLOW,AND/OR FEATURE FLOWS,FOR SINGLE OR MULTIPLE "4"!!.."....!!!. Scale No Scale 0 f- 3'-i Suction Outlets @ gpm max.flow(see note) Telephone Number PUMP SYSTEMS.EACH PROJECT IS ENGINEERED SPECIFIC TO '•+••a• Date Sept 2023 Scale 0 O O Suction Outlets @_ gpm max.flow(see note 3) THE POOL SHOWN. •MOTE alto MMraw,BE EowL ro OR o o,r* 4'i I 32' Channel Drain @ I84 gpm w/ 2" ports(see note4) sin ee s uLn von Of{1.1 shoe[ SM wcE tosocc000 FOR VERlna.aN Name '2 0 -a m QJ m L (IJ NNv QJ •> m O LL DECK(PAVER POOL BEAM THICKNESStal) H t OR CONCRETE) 8" u Mil 1.1.TYPICAL POOL WATERLINE •� y 5161113116111111R3111610COPING 4..1 H CO 'olll=III li U Ln V ut 111111111. ` (2)13 CONT.BOND BEAM •O °i o a f PiI► A S °. "OC IZ I EACH WAYREBAR®12CONTINUOUS N POOL SHELL CONCRETE MIN.POOL WALL y '' 00144 " POOL SHELL THICKNESS i �. STATEMIN �r FLOOR OL �lb,:`'1-OR�0�'W THICKNESS "•SSIONt:I."" MCMWRA1 MMT MA,urTr.mR. 9/12/2023 . A,,M EST R®ARAS SHOWN MEREST. ANN MADE IS 'CONCRETE COVERAGE REINFORCEMENT ALL AQUATIC u 4-IN POOTMOS r IN ALL OTHERS ENGINEERING >R PSI NMP ORAOE CONCRETE READY MIX POOL WALL/FLOOR SECTION •EAR MOS LAPPEO®IOEARWANETEIIS � 1/2".1" 9rE�+�/� E Weida tenMOM of Authareesee man TW tame 0 Lakes/IW.NM Lena O Lek.r..ems elep.eAM/rteeiaN.ae. • !Ii DECK(PAVER W f i "a OR CONCRETE) WATERLINE N 3 P POOL BEAM THICKNESS Z & {I I / 8' (2)N 3 CONT.BOND BEAM S 1 ;C p —TOP STEP VARIES(SEE PLAN) + 0 a \ 4I I 7- S"MIN. `WATERLINE , s 1._D.. REBAR PLACEMENT (1YP) z S SAME AS POOL WALL/ e 6 ": FLOOR SECTION 4 *N -- STEP HEIGHTS H POOL S . 1 TO BE UNIFORMSTRUCTURE � (• ;= Lin *3REBAR012" " __ • OC EACH WAY v V i�.N C) e CONTINUOUS IN . 3L. Q o POOL SHELL ' ' .. 4.1 . ro77. VI VI BENCH SECTION STAIRS SECTION scale 1/2".1" 112".1" 1n".1" Date Sept 2023 Sheet SM-3 Name VSFHP185DV2A (New Pump Model) Set les aemawr,:e.r�,wwh,.w-..xsa.s..p,a,:v,.K.s..�n,•,w,,...,...;,.�..w"w•..,.:+.,warwwsw+..w.>++y�vWa+mmwe�sasw:sv,..a.iarr,.;vvww..�.awnw,x ..:.w;mw....�.xw:ww,.�..�w*.,,r.xe�,•+ss:x.,wx,w.,m...w..ma..�ut ww.w.a+..*s..•raa,�w.nx.,.;..w.er++vaxM..,w,_u...,..,k. .,..,w.:.,�,. 1 "Must purchase a JEP-R or lgPurnp01 if there Is not automation "No need for a ttmoctock for salt(built In auxiliary) `Dual Voltage 115/230 .-1414 VS FloPro 1.85 HP Variable-Speed Pump, 1161230 VAC, 2 Aux Relays, wlo Controller V8f1/p1a0ov4A PiMom:ance Curves Features & Benefits kJ 74LO RPM ▪ 115/230 VAC y© �_ • Medium Head Pump s 30 'RPM • Two Auxiliary Relays • Dry Contact Relay Control for old automation compatibility 6' `"`-~-- e The pump will not de-rate at 3450 RPMS. This allows to the 40 2400 RPMpump to move the same amount of water at 115V/230V >0 1730 RP1A 70 1300 EtPhl 10 6002PF.1 0 17 27 .33 42 50 60 30 002 92 172 110 120170 140 Flow Rate,Oaslons For Mins!*(OPM) cMP 32" CHANNEL DRAINSCMP#25506-32X-000* SGB-ZOf}$ *-,$ COMPLIANT FkrerWIrS Read and keep these instructions for futu!e reference. „ Always plumb and install ail suction fittings according to all building caries that apply in your area. WARNING:When using two or more suction fittings on a common suction line must be located on two different planes(i.e.,one on floor and one on the waif. suctions must be separated by a minimum of 3 t or they WARNING:DO NOT locate suction outlets on seating areas or on backrests for such seating areas. The maximum flow rating for this suction fitting with the center port plugged and outer ports open is 308 GPM(Floor)and 212 GPM (Wall)when using 2.5'plumbing and 268 GPM(Floor)and 192 GPM(Wall)when using 2:plumbing. The maximum flow rating for this suction fitting with the outer ports plugged and the center port open is 200 GPM(Floor)and 168 GPM{Wall)when using 2.5' plumbing and 184 GPM(Floor)and 176 GPM(Wall)when using 2'plumbing. This suction fitting is designed for installation on side wail or floor of hot tubs or pools. DO NOT adapt suction fitting to any pipe size smaller than ASTM 2"SCH 40 PVC. Suction fitting and fasteners should be observed for damage or tampering before each use. Missing,broken,or cracked suction fittings shall be replaced before i4"' '+�uu +� •-��••,�A�,•�=•�....n.a use.Loose suction fittings Thal+be reattached or replaced before use. iso . °' f ,.so . °ice' Mount suction fittings on the walls,in the foot wells of hot tubs or 4 f} }' pools. Do not mount directly under seas. Follow all winterizing °. FD insb actions and recommendations of your ,���j`� ={-�`-- - ya pool and spa professional. D rt.F. 'naA Open area of the suction cover is 38.79 int. A s Tools Needed Phillips Head Screwdriver �,r«.�m`{1� t rs, oma � F� i 150 inn. iti.D�ww INSTALLATION INSTRUCTIONS ',. i..:.-:.2:-._...._==`-.._L 1. Install sump provided or construct sump per fj ; i ANSI/APSP-16 Figure 2(see below) 2. If mounting frame is provided,secure it in concrete ` or piaster. canu>tosa 1 a.iftkis dt.we Vebc 3• Use mounting screws to secure cover to frame or sum ir".°' '~" "1"""` Head Loss NOTE In the event that one suction outlet is completely (Pax iO3) r oa o ,. � r,,, blocked,the remaining suction outlet(s)serving that system 40 MUST have a flow rating capable of the Ml flow of the pump(s) for the spec suction system NOTE Increasing size of the pump may increase flow rate of 20 suction beyond rated safety limits causing entrapment or death. CAUTION:Flair or body parts bloddng the spa or pool suctions o maybecome ma againstg 30 160 240 320 Aped and held the suction fitting. Flow(GPM) Entrapment against the suction fittings can result in drowning or other severe injury. Never sit on or lean up against suction fittings.Never exceed the maximum allowable flow rate stated REPLACEMENT PARTS 1 on the suction fitting. The suction fitting and fasteners should Reas parts wi,xin be inspected for damage or tampering before each use of the 25506-32X-040 25506-32X-100 r ra aunt yeas¢r immaduxty upas dence of fading. Missing,broken,or cracked suction fittings shall be Cover 25506-32X-020 Cover 25506-32X-020 replaced before using this facility. Loose suction fittings shall be Sump 25506-320-010 Frame 25506-320-110 "eidgr &radabrxi reattached or replaced before use of this facility. Plus 255Screw 610088-042-0 42.azo Screw 61008-042-022 22 •X CAN BE ANY Dior 0-9 TO Optional Debris Guard Optional Frame Support DENOTE COLOR 25506-320-03o 25520-050-120 lefAltailftec To reduce the risk of drowning from hair and body entrapment install suction exceeds the flow rete of your system by at least 25%. Always use multiple fittings t%in a over breaks,ks,rate in gallons damaged,or per minute that system down immediately. Do not use the system until damaged parts haw been replaced. the fitting/cover is is musing.abut the WAanat gth Kapor wear swp hair and dothing a minimum of 12 inches ft om all suction fittings and drains at all times.Persons with long hair should secure hair to a minimal le.of r ,ag ChildrenShould never be left unattended at any time In a swimming pool,spa.or bathtub. se sure the cwrees r.00mm.+utetions. 0713.b CUSTOM MOLDED PRODUCTS ( 36 HERRING ROAD, NEWNAN, GA 30265 I WWVVC-M-PCOM Technical Specifications andy„,„ CS Series Filters c j---7-__ ___> Pro/Series tyZonIACe' 4 0 t Ma O L ilipalri -‘1. if i""I,I J'l"i 11 A. ii 187-" MIIIIII W. 3'/' Part No. Description Size Specifications and Dimensions,CS Series Filters CS100 CS Cartridge Filter 100 Sq. Ft. Model No. CS100 CS150 CS200 CS250 Filter Area 100 ft2 150 ft' 200 ftz 250 ft CS150 CS Cartridge Filter 150 Sq. Ft. Design Flow Rate 1 gpm/ft2 .85 gpm/ft' .625 gpm/ft' .5 gpm/f12 CS200 CS Cartridge Filter 200 Sq.Ft. Maximum Flow 100 gpm 125 gpm 125 gpm 125 gpm CS250 CS Cartridge Filter 250 Sq. Ft. Six(6)Hour 36,000 45,000 gal- 45,000 45,000 gal- Capacity gallons Ions gallons Ions CS Filter Head Loss Curves Eight(8)Hour 46,000 60,000 gal- 60,000 60,000 gal- Capacity gallons Ions gallons Ions Normal Start Up 8 Pressure 6-15 psi 6-15 psi 6-15 psi 6-15 psi _3 Max.Pressure Working res corking 50 psi 50 psi 50 psi 50 psi sl Design I f I Design Cartridges Los Pressure Required 1 1 1 1 -2 Drop (ft head) 4 t Shipping Weight g ht 28 lbs. 28 lbs. 34 lbs. 36 lbs. Height('A') 3234° 323/e` 421/2" 42Y" 2 it - 1 iII , 0 30 60 90 120 -••• CS150 Flow Rate(gpm) - • CS200 - CS250 CS100 www.ZodiacPoolSystems.com ©2011 Zodiac Pool Systems,Inc.SA6259 0611 .r ZODIAC°is a registered trademark of Zodiac International,S.A.S.U.,used under license. HOME ICONTACT iJS —__-1 Wit ?Op l4:1J;.RDIPRODUCT h4A.NNALS1101ARRANTYPEGICTPATION •i" i_Fr ' i . Read Before ill Liar 's" P' ,41,'-i'.-V .'re0 'ChisFO You Buy Poolguard Alarms: •Pool Alarm-Model PGRM-2 1NGROUND POOL ALARM - MODEL PGRM-2 •Pool Alarm-Model PGRM-SB •Gat a Alarm Door Alarms -NEW t )-NSF Certified to ASTM F 2208-08" •Doo rAlarm-DAPT 2 (Sounds in 7 seconds) •Doo-- r Alarm-DAPT-WT {Sounds immediately) PGRM-2 Installation Video ,. -, Other Information: • y*' -c'7"' -,� , =-f`�-" '1 1 Con---t 115 �4 1-..4.-- , fn it •Buy Poolguard -':,!:-;.-A ' •Product Manuals - a: .. •Dews Fro h' m Poolguard E t ',4142.41, 14.11111-1-1: •Warranty Registration --z.� - r •Model PGRM-2 Installation Video ;'' t As Well As the states of CA, •Model PGRM-SB Installation Video CT, FL,and TN 31Mc . •Detects Intruders r. - - •Sits on Deck ' •Battery Powered'= j ` V " -Low Battery Indicator iiiiisit .,...„;-_::,,,- 1.....--', fir.; ,-v.gs 1 f •New Sensing Technology ?; k •Easy to Use IPIr - . • ` •Completely Portable tr x '� `"F 1 -. l&& s_ t7,. •Automatic Reset - •Affordable Price • Important Safety Feature •In House Remote Receiver • Horns are 85 dB at 10 feet i ! POOLGUARD/PBM INDUSTRIES, INC.has rt- d been manufacturing pool alarms,door alarms, P�4 and gate alarms since 1982.All Poolguard •- products are proudly Made in the USA. r Poolguard Pool Alarms were tested and'Top ��`, r , Rated"by Good Housekeeping Magazine. :;/� ; Poolguard Pool Alarms have been Tested and r: f . - Certified byNSF International to the ASTM i Y�, -: i.1::4 . ? Standard Safety Specification for Residential f v 4 x;; Pool Alarms,ASTM F 2208-08. '' rte,: POOLGUARD IN GROUND POOL ALARM NSF CERTIFIED TO ASTM F 2208-08 NEW Weatherproof Design NEW Sensing Technology NEW Microprocessor Technology 3 Year Warranty • The Poolguard POOL ALARM, once installed in the pool, cannot be de- activated; it is always in the alarm ready mode. • Tamper Proof: Poolguard POOL ALARM will sound an alarm when removed from the pool. • Sleep mode:when you would like to use your pool, simply remove the alarm from the pool and put it into sleep mode- • Automatic Wake-up: The Poolguard Pool Alarm will automatically wake up and run a system test when installed into the pool. • The Poolguard Pool Alarm comes with an in-house remote receiver that has a range up to 200 ft., and comes with a 12 volt power supply. • The Poolguard poolside alarm works on a 9-volt battery(not included); with a battery life of approximately one year. • Audible low battery indicator at the poolside alarm is also indicated by the in house remote receiver. • New sensing technology provides less chance of false alarms due to wind, rain or small objects such as sticks or toys entering the water. • Poolguard Pool Alarms have been tested and comply to the ASTM Standard Specification for Pool Alarms ASTM F2208, in a 16'x 32'pool. Poolguard Alarms can be used in pools up to 20'x 40'or 800 square feet. • The Poolguard Pool Alarm can be used with a solar blanket. • Most reliable, advanced, and affordable alarm available. • Poolguard PGRM-2 is designed to detect intrusions similar to a One year old child inground Pool Alarm PDF manual All Products Proudly E 40i0 m, QE'iriilECALL TOLL-fes