1525 BEACH AVE RES23-0148 Davey DWG. Revision 09-13-23 - Copy_1DESIGN CODE- 2020 FLORIDA BUILDING CODE °- RESIDENTIAL DESIGN LOADS, ACTUAL AND UNIFORM WORK CLASSIFICATION: HOUSE - ALTERATION LEVEL II ROOF LOADING (cd=1.25) TOP CHORD LIVE LOAD 20 psf TOP CHORD DEAD LOAD 15 Psf DEFLECTION CRITERIA. ROOF FRAMING: LIVE LOAD L/240 TOTAL LOAD L/180 GENERAL NOTES' MEANS AND METHODS: THE STRUCTURAL ENGINEER SHALL NOT HAVE CONTROL Q_R BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES, OR SEQUENCES; FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR OR ANY OTHER PERSONS PERFORMING THE WORK OR FOR THE FAILURE FOR ANY OF THEM TO CONSTRUCT THE WORK IN ACCORDANCE 46TH THE CONTRACT DOCUMENTS. LIMITS OF STRUCTURAL ENGINEERING DESIGN RESPONSIBILITIES: THE ITEMS SPECIFICALLY DESIGNED BY THE STRUCTURAL ENGINEER ARE LIMITED TO THE FIBERGLASS COLUMN REPLACEMENT AS SHOWN IN THE THESE PLANS. ITEMS NOT DESIGNED INCLUDE WATER/WEAIHERPROCHNG AND ARCHITECTURAL EMBELLISHMENTS NOT SPECIFICALLY INDICATED (EYLBROwS, CORNICE, CORNICE RETURNS, PROJECTIONS, ETC) AND ANY OTHER ARCHITECTURAL, MECHANICAL OR ELECTRICAL SYSTEM. WALL SHEATHING SPECIFICATIONS: MIN. '&% 24/16, APA RATED OSB OR PLYWODD SHEATHING, FASTENED W/ 80 9 6" O.C. EDGE AND 6" D.C. FIELD, SHEATHING SHALL OVER LAP FLOOR SYSTEM 16" MIN AND EXTEND TO THE UPPER TOP PLATE. PROVIDE BLOCKING AT PANEL JOINTS. VAND LOADING: ASCE 7/16 BASIC WND SPEED (ASCE 7-16) --------------130 MPI IMPORTANCE FACTOR --^---^-- ----------------- 1.00 MEAN ROOF HEIGHT ----------------------- 20.0 FT BUILDING CATEGORY --------------------------- II EXPOSURE CATEGORY - - - - - - - - - - - - - - - - - - - - - - D ENCLOSURE CLASSIF€CATION ----------------- ENCLOSE[ INTERNAL PRESSURE COEFFICIENT -------------- ± .18 COMPONENTS & CLADDING ALLOWABLE DESIGN PRESSURES TRIBUTARY AREA (sl) INTERIOR EDGE STRIP (PSF): ZONE (PSF) 'a' = 4'-6" 10 I 430-2 -32.9 430-2 -4C.5 50 +27.1 --29.6 427.1 -34.2 100 I +25-7 -28.2 425.7 -31,2 NOTES - 1. TYP. CONNECTION AT STUD COLUMNS, I' (3) ROW OF IOd JACK -TO -KING ASSEMBLIES, CORNER POST, ETC. -7 NAILS Q 8` O.C. 2. SPECIFIED NAILING REQUIRED FOR EVERY PLY IN STAGGER"tQ , ADDITION TO (2) PLYS NH N 2x4 L[EMBER (1) RUvr OF lad (4) ROWS 12d NAILS 0 4" 0_C. AT 12" O.C. 2x6 MEMBERS ! EA. SIDE. (2) ROW OF 10d (3) ROW 12d� NAILS 0 4` O.C. AT 12" O.C. 2 PLY 3 PLY STAGGERED EA, SIDE, BEAM. BEAM, 2 & 3 PLY BEAMS 2.4 OR 2x6 POST 21c6 POST }" THRU BOLTS }' THRU BOLTS 0 24" O.0 Q 24' O.0 3 -PLY 4 -PLY 14" LVL AND GREATER 1 BUILT-UP MEMBER FASTENING e ac Jx•aEXISTING FLdOR SYSTEM -r nc. z :a e>o z z , ,...._. ORIENTATION ._.. CONTRACTORI TO VERIFY ' FAMILY R OM ° f r12 EXISTING BEAM ABOVE .fNl TO REMAIN FASTEN TO — I NEW BEAM w/2-HTS16,� 7}"x7j" PSL POST SET ON SLAB. PROVIDE 2 LAYERS OF I ROOFING FELT BELOW POST I SIMPSON LTT20B Ji HOLDCWN RECESSEDEAM TO POST SEE 2/51.0 /13./2-HTS16 1, SIMPSON HTT5 HOLOOWN SEE ' 2/S1.0 SIMPSON HTT5 BEAM TO POSTEYf HOLDOWN SEE /2 MSTA24 ; 2/51 D -_ _- ,m. � ., a u WALL TO BE Jl N! HGUS612 WALL. TO BE i POSTS1„„„.�........ REMOV'LD .. f HANGER REMOVED WALL TO BE r:u xx� 1 O REMOVED LL 1G X+ BEAM TO POST DEtT /2-MSTA24 (4)2x6 SPF#2 TO BE -,/n' GALLE E POSTS I: I EXISTING FLOOR SYSTEM -) i� 1� -1 ORIENTATION WALL, j��� REh:OO SIMPSCN HTT5— CONTRACTOR TO VERIFY ;IHOLpOwN SEE r;A7H y. (4)2x6 { 2/S1 0 lea jj SpF#2 - I .... POSTS vs - `_' BEAM TO POST• 1 SIMPSON HTTS 1 , I "! w/2-MSTA24 HOLDO%N SEE 2/S1.0 3 I <G 6 BEACH BATH, FOYER�,i ! - ) € 1 -1 SII MIN 2 PLY STUD IN LIEU OF 2[ STUDS ITS ACCEPTABLE TO 9 L' SISTER A 36' LONG STUD MIN 2 PLY FASTEN w/12 -0.131x3` GUN 1 jJE STUD NAILS- SIMPSON HTT5 OR € I N^ € I E HDUS. FASTEN �0 LIVING R00!.4 26-I0d COMONS� •5 y. 11 E(i e ! !yi r _,,;._t, €I ` J3 f 9a" THREADED ROD EPDXIED 7,5' MIN TITEN HD HTT5 or HDUS L7120B HOLD DOWN ATTACHMENT DETAIL 51.0 FIRST FLOOR PLAN 12x6 SPFp2 a�p�f„u,pr. NCR J. s96 EN.. 71461 rZ: x STATE OF �+�,•= �EORI -NHM1.� FSSlONALE -12.23 Chri—ph” j Sa LouriR SL rE071461 ft..A.PR0IESSIOY2IEYC ak MERIEW TIM NJS MNENr W.5 SEEN ELECIE W:LLYMECARS R.,PEOR 0111YxLx SIIIDIIRW,YEOYMCOD ESW. AvmelmeAnaxeooE AiEN AQTOI 0.R WNEOAY9 sIT0 ANa rxE 11 LJINEN1RAfI0N CWEYJSIBF YFAIFIEG ONAYYELEEIROMC 50PF5 SABO STRUCTURAL ENGINEERING CAP32529 215 91H AVE N AX 0EAC11, FL12250 909.7125750 CHRIS@SA60ENGCOM PIN P401E 1525 6EACT1 AL'E SSE lo. x'-a59r ISSUE DATE MITT 0912.2) REVISK)NS DATE LL.I OQ LL � U N LUm L)..( LU Ln Z N = Q LL, Q ED Q Z U ❑C O Q Z Q (A LU JY FIELOALTERATION EN .:i"Iu1M1�lyt �>`[ li![luf4llLua f saNlri�fl v.'h MU3 hiLavlUirvU C1taN>saal El�NGw•ILosItC4r Cf[ii�im HlL fiiill¢L�coP s> flf[SUONlsLsu SCALING an Nar x.LL aful.:cmni twu ' n, :ef%emrinc�' +L ,rvl[:uu[ to �k�sat DESIGN CRITERIA AND GENERAL NOTES SHEET S1.0 SHEET 1 OF 1