Loading...
450 E Sailfish Dr ACC23-0023 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: WINKLER PETER A 450 SAILFISH DR E ATLANTIC BEACH FL 32233-4133 COMPANY:ADDRESS:CITY:STATE:ZIP: TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 171398 0000 ROYAL PALMS UNIT 02A3.00 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 450 E SAILFISH DR ACCESSORY SINGLE OR TWO FAMILY ACCESSORY Construct 10'x10' Storage Shed $3000.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247- 5814) to request an Erosion and Sediment Control Inspection prior to start of construction. 2 PUBLIC WORKS DUMPSTERS/ROLL-OFF CONTAINERS INFORMATIONAL Notes: Dumpsters and roll-off containers must be used in compliance with Section 16-8 and must comply with all standards, per City code. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 9/12/2023 PERMIT NUMBER ACC23-0023 ISSUED: 9/12/2023 EXPIRES: 3/10/2024 ACCESSORY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $70.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $35.00 PW REVIEW BUILDING MOD OR ROW 001-0000-329-1004 0 $25.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00 TOTAL: $234.00 3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. 4 PUBLIC WORKS CONSTRUCTION SITE MANAGEMENT INFORMATIONAL Notes: Provide construction site management plan, including location of silt fence, dumpster, portable toilet. Right-of-Way Permit is required if using right-of- way for construction parking. 5 PUBLIC WORKS GRASS INFORMATIONAL Notes: Full site to be grassed. 6 PUBLIC WORKS REVISION INFORMATIONAL Notes: Any plan change must be submitted as a Revision to the Building Department. 7 PUBLIC WORKS DEBRIS REMOVED INFORMATIONAL Notes: All construction debris must be removed from job site by Owner. 8 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Owner. 2 of 2Issued Date: 9/12/2023 PERMIT NUMBER ACC23-0023 ISSUED: 9/12/2023 EXPIRES: 3/10/2024 ACCESSORY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 ACCESSORY STRUCTURE PERMIT APPLICATION CHECKLIST (Shed – Pergola – Covered Patio – Summer Kitchen – Etc.) City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us Website: http://coab.us * Click here for Permit Submittal Instructions REQUIRED PERMIT APPLICATIONS □ Building Permit Application (check “new” in the class of work) □ Construction Site Management Checklist □ Impervious Surface Calculation Formula (if applicable) MINIMUM PLAN SUBMITTAL REQUIREMENTS □ Job value must be listed on permit application □ One (1) digital Survey or Site Plan showing the location of work and setback dimensions to all property lines □ One (1) digital copy of NOA’s or State of Florida Product Approval □ One (1) digital set of Drawings (signed and sealed by a Florida Licensed Architect/Engineer) PRE-FAB STRUCTURE □ One (1) digital set of Plans (signed and sealed by a Florida Licensed Architect/Engineer) SITE-BUILT STRUCTURE PERMIT REVIEW STOPS (Your application will be reviewed by the following departments) □ Building Department □ Planning and Zoning □ Public Works OTHER REQUIREMENTS AND INFORMATION (where applicable) □ Electrical Permit Application (if applicable) □ Mechanical Permit Application (if applicable) □ Contractor Registration Requirements (if the Contractor is not registered with the City of AB) □ Owner/Builder Affidavit (if Owner/Builder AND Homestead Exempt) □ Notice of Commencement (if job value over $2,500 required before 1st inspection) WHAT TO EXPECT □ You will be contacted if you are missing any documents (approximately 10 days after submission) □ Resubmission of documents can be made by emailing Building-Dept@coab.us □ Resubmission of documents shall include a Revision Request/Correction to Comments Sheet □ Permits will be issued approx. 7-10 business days after all correct documents have been received and approved □ Permit will not be issued until all departments have approved it and payment has been made □ Schedule your inspections by calling 904-247-5814 before 4:00 p.m. for a next day inspection Please note that this checklist is not intended to be all-inclusive Due to changes in codes, regulations, and ordinances, other requirements may apply. City of Palm Coast building department shed plans attached Not applicable since project area <250 sf. Building Permit Application ACC23-0023 Construction Site Management Checklist CONSTRUCTION SITE MANAGEMENT CHECKLIST City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us Website: http://coab.us A construction site management plan conforming to the City of Atlantic Beach Code of Ordinances Sec. 6-18 must be included with every permit. An approved Construction Site Management Plan must be posted on the job site and available for review. The Construction Site Management Plan must include the following information: 1. Parking plan showing how the site will be accessed and all onsite and abutting street parking areas. 2. Location of construction trailers, loading/unloading area, and material storage area. 3. Location of chemical toilet area: Chemical toilets must be kept out of the City right-of-way and not further than 15 feet from structure and the door shall face the structure that is under construction. 4. Dumpsters are to have tarp covers or rigid covers on windy days. Dumpsters must be removed prior to issuance of Certificate of Occupancy or Certificate of Completion. 5. Traffic control plan showing access with dimensions, area to be stabilized, narrative on phasing of construction with adequate parking and delivery of materials. 6. Site cleanliness: Contractor must have the entire construction site cleaned by Friday of each week. This means removal of scrap lumber, concrete remnants, and other such construction debris including cans, metal, plastic, and paper. 7. Erosion and Sediment Control: Contractor must maintain all elements of the approved Erosion & Sediment Control Plan (silt fence, catch basin filters, etc.) until sod or other stabilization has been placed and approved by Public Works. 8. Other activities, where special conditions are identified by the Building Official. Failure to comply with the Construction Site Management Ordinance may result in a Stop Work Order being issued in accordance with City of Atlantic Beach Code of Ordinances Sec. 6-17 (b)(3). Revised 03.30.2023 Proposed 10'x10' shed construction site CONSTRUCTION SITE MANAGEMENT PLAN Parking Area/Loading and Unloading Area Access site on south side of house. Notes: 1) Chemical toilet requirement not applicable. Toilet facilities in house will be utilized. 2) There will be no construction trailer. 3) Construction dumpster will not be used. Minimal construction waste anticipated. Gener- ated waste will be disposed with general household waste. 4) Traffic control plan requirement not applicable. 5) Erosion and sediment control measures not anticipated since construction site 100 sf. Temporary storage area for construction materials Site Plan 16.25 ft16.22 ft 6.25 ft16.75 ft +/-16.25 ft +/-6 ft +/-Proposed 10'x10' shed SITE PLAN Product Approval Information Page 1 of 4 Updated 06/21/21 PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA (*REQUIRED) *Project Address: _________________________________________________________________________ Permit #: ___________________________ *Owner/Project Name: _______________________________________________________________________________________________________ As required by Florida Statute 553.842 and Florida Administrative Code Rule 61G20-3, please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www.floridabuilding.org. Category/Subcategory Manufacturer Product Description Limitation of Use State # Local # A. EXTERIOR DOORS 1. Swinging 2. Sliding 3. Sectional 4. Garage Roll-Up 5. Automatic 6. Other B. WINDOWS 1. Single hung 2. Horizontal slider 3. Casement 4. Double hung 5. Fixed 6. Awning 7. Pass-through 8. Projected 9. Mullion 10. Wind breaker 11. Dual action 12. Other 450 Sailfish Drive East Peter Winkler; 10'x10' storage shed construction project Masonite Steel exterior door 22513.6 Apple Fasteners, Inc.14"x21" shed window 21990.1 Page 2 of 4 Updated 06/21/21 Category/Subcategory Manufacturer Product Description Limitation of Use State # Local # C. PANEL WALL 1. Siding 2. Soffits 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D. ROOFING PRODUCTS 1. Asphalt shingles 2. Underlayments 3. Roofing fasteners 4. Nonstructural metal roof 5. Built-up roofing 6. Modified bitumen 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 11. Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane roof 17. Other GAF / Owens Corning 3 tab asphalt shingles 10124.1 / 10674.1 Tamko ASTM D226 Type I Asphalt felt 12328.5 Page 3 of 4 Updated 06/21/21 Category/Subcategory Manufacturer Product Description Limitation of Use State # Local # E. SHUTTERS 1. Accordion 2. Bahama 3. Storm panels 4. Colonial 5. Roll-up 6. Equipment 7. Other F. STRUCTURAL COMPONENTS 1. Wood connector/anchor 2. Truss plates 3. Engineered lumber 4. Railing 5. Coolers-freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9. Plastics 10. Deck-roof 11. Wall 12. Sheds 13. Other G. SKYLIGHTS 1. Skylight 2. Other H. NEW EXTERIOR ENVELOPE PRODUCTS 1. 2. Simpson Strong Tie, Inc.H3, H6, RSP4 straps 10456.7 City of Palm Coast Building Department Approved Shed Plans & associated email correspondence bic_board@yahoo.../Inbox Aug 2 at 9:05 AM RE: City of Palm Coast Shed plans Jones, Mike <mjones@coab.us> To: Pete Winkler <bic_board@yahoo.com> Just sent the pdf to the Building Official, asking for his reply. Thanks, Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 (904) 247-5844 Email:mjones@coab.us -----Original Message----- From: Pete Winkler [mailto:bic_board@yahoo.com] Sent: Tuesday, August 1, 2023 4:09 PM To: Jones, Mike <mjones@coab.us> Subject: City of Palm Coast Shed plans Hello Mike, As we discussed earlier, I am interested in building a small storage shed (8'x12') in the backyard at my house (450 Sailfish Drive East) using the "skid" option instead of a concrete foundation. I found the attached shed plans (published by the City of Palm Coast) on the internet at this link: https://docs.palmcoastgov.com/departments/building/standard plans for storage building or shed.pdf I plan to file for a building permit and would like to know if the attached shed plans are acceptable structural plans for the shed. If not, please advise me on the correct course of action. Please reply at your convenience. Thank you for your time. Pete Winkler Want to receive City of Atlantic Beach news by email? Just say so in an email to info@coab.us. Follow the City of Atlantic Beach on Facebook at www.facebook.com/cityofatlanticbeach. Florida has a very broad public records law. Most written communications to or from state and local officials and agencies regarding state or local business are public records available to the public and media upon request. Your email communications, including your email address, may therefore be subject to public disclosure. RE: City of Palm Coast Shed plans - Yahoo Mail https://mail.yahoo.com/b/folders/1/messages/AO0ZFbllNG96ZMpUjwo... 1 of 1 8/22/2023 10:13 AM bic_board@yahoo.../Inbox Aug 4 at 11:19 AM shed plans Jones, Mike <mjones@coab.us> To: bic_board@yahoo.com <bic_board@yahoo.com> Cc: Askew, Amanda <aaskew@coab.us>,Gindlesperger,Toni <tgin@coab.us>, Angers, Vanessa <vangers@coab.us> Good Morning. We will accept those drawings from Palm Valley Building Department based on the square footage they prescribed. Thanks, Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 (904) 247-5844 Email:mjones@coab.us Want to receive City of Atlantic Beach news by email? Just say so in an email to info@coab.us. Follow the City of Atlantic Beach on Facebook at www.facebook.com/cityofatlanticbeach. Florida has a very broad public records law. Most written communications to or from state and local officials and agencies regarding state or local business are public records available to the public and media upon request. Your email communications, including your email address, may therefore be subject to public disclosure. shed plans - Yahoo Mail https://mail.yahoo.com/b/folders/1/messages/AOQzCJ9Qk5P1ZM0XGw... 1 of 1 8/22/2023 10:12 AM STANDARD PLANS for RESIDENTIAL STORAGE BUILDINGS or SHEDS The City of Palm Coast Building Department is pleased to announce a program for home owners who wish to build their own storage building or shed. The Department's Plan Review staff as developed a typical design which can be used to construct a wood framed building with a maximum width and length of 10 feet and a maximum height, at the roof peak, of 12 feet. The plan provides options for placing the building on a concrete slab or an anchored wood floor system, placing door(s) and/or window(s) in the walls and allowing you to choose the finish material to be applied over the exterior structural sheathing. DEVIATIONS FROM THIS PLAN ARE NOT ALLOWED The plan is simple, easy to read and provides many details and notes to guide a person with basic knowledge of construction through the project. Revised 2/20 BUILD -A -SHED Standard Details for Wood Framed Sheds Index to Drawings Description Cover Sheet General Notes Foundation Plan (Option 1) Wall Section Enlarged Details Floor Framing Plan (Option 2) Cable Tie Down Details Floor Framing Wall Framing Framing at Door Opening Framing at Window Opening -Sidewall Framing at Window Opening -Endwall Connector Details Ridge Beam and Collar Beam Details Roof Framing Plan Nailing Pattern I Wood Framed Sheds I Cover Sheet Drawing No. C-1 G-1 A-1 A-2 A-3 AA A-5 A-6 A-7 A-8 A-9 A-10 A-11 A-12 A-13 A-14 I Dwg. Number:C-1 City of Palm Coast 160 Lake Ave Suite # 137 Palm Coast, Fl 32164 386-986-3780 Revised 2/20 General Notes 1.Prescriptive design parameters are according to the 2017 Florida Building Code Section 1609.1 Exception No. 2 and the American Wood Council Wood Frame Construction Manual 2015 edition. 2.Wall sheathing shall be exterior grade wood structural panel with a minimum thickness of½ inch if installed horizontally with long dimension on vertical studs or a minimum thickness of 19/32 inch if installed vertically on studs. 3.Exterior wall vapor barrier, siding or finish is optional. 4.Wall studs spacing shall not exceed 24" on center. 5.Window openings are optional, locations are at the center of the wall. Width of window opening shall not exceed 4 ft. 6.Header lumber for window and door openings up to 4 ft wide shall be made of 2-2"x 4". 7.Jack studs to support headers on window and door openings up to 4ft wide shall be made of 1-2" x 4" located at each end of the header. 8.Roof rafter spacing shall not exceed 24" on center. 9.Collar ties (collar beams) of nominal 2"x 4" lumber shall be located in the upper third of the attic space and attached to rafters with a minimum of 2-1 0d common nails at each end. 10.Roof sheathing shall be a minimum of7/16" thick of wood structural panel and shall be installed with the long dimension across the rafter supports. Edges of all 7 /16 inch roof structural panel supported at 24" on center, shall be supported with blocking or edge clips. 11.Roof structural panel shall be attached to supports with Sd common nails or 1 0d box nails and spacing shall not exceed 6" on center. 12.Roofing material, windows and doors shall have a Florida product approval and shall be installed according to manufacturer's specifications. I Wood Framed Sheds I General Notes I Dwg. Number:G-1 I 1 ENTER D!MENS!ON (10'·0" MAXIMUM) 1 01'/TER ElEVA11ON TYPE, FRONT, RIGITT, REAR OR LEFT ENTER DIMENSION (10'·0" MAXIMUM} @ER ELEVATION TYPE: FRDNT, RIGHT, REAR OR LEFT SHED ELEVATIONS INSTRUCTIONS: 12'-0" maximum _!, _____ � 1 ENTER DIMENSION (10"·0" MAXIMUM) 1 NTER ELEVATION TYPE: FRONT, RIGHT, REAR OR LEFT NTER. ELEVATION TYPE: FRONT, RlGl-ff, REAR OR LEFT STEP 1: IDENTIFY ELEVATION TYPE FOR EACH ELEVATION (FRONT, RIGHT, REAR AND LEFT) STEP 2: SKETCH WINDCW AND DOOR OPENINGS ON EACH ELEVATIONS. DENOTE SIZE Of EACH. STEP 3: IDENTIFY WALL COVERING MATERIAL(S) TO BE USED (vinyl siding, hardiboard, stucco, etc.) ________ _ STEP 4: IDENTIFY ROOF MATERIAL COVERING TO BE USED (ashpahlt shingles, metal panels) __________ _ STEP 5: IDENTIFY COtORS OF WALL MATERIAL, TRIM, DOORS, WINDOWS AND ROOF ON COLOR AND MATERIAL SHEET. Left (South face)Front (East face) Rear (West face)Right (North face) 10'-0"10'-0" 10'-0"10'-0" 5/8" T111 plywood (back and sides), 1/2" exterior plywood front with Hardiboard plank siding. 3 tab asphalt shingles 14"x21" window 14"x21" window 36" x 80" steel exterior outswing door ,c---2X4 BOTTOM PLATE 1/2" MIN ANCHOR BOLTS @ 30" 0/C • • • • ' ill I • 2 I 0 � • • II • L _______________ J .1-,.-____,,__ t') I • 6" Max. From Opening L=10'-0" MAX. THIS DETAIL IS IN COMPLIANCE WITH THE WIND LOAD PROVISIONS FOR 120 MPH OF THE PRESCRIPTIVE DESIGN PARAMETERS ACCORDING TO THE 2017 FLORIDA BUILDING CODE SECTION 1609.1 EXCEPTION NO.2 AND THE AMERICAN WOOD COUNCIL WOOD FRAME CONSTRUCTION MANUAL 2015 EDITION. OPTION 1 • 6" Max. From Opening 1'-3' DETJ.L NIJMBER: SPEC. NUMBER: SLAB ON GRADE = 1---'-=----'--='-------"----'----=----"'-----r 3/8" -.1 • -o" OATE: RE'ASION OATE: A-1 WOOD RAMED SHEDS FOUNDATION PLAN 12/14/04 3/15/05 DRAWN BY: APPROVED BY: ANGEL Not used 1,---�---APPROVEO-ROOF!NG MATERIAL :�rt��¾�lit�1 !:AT�U§S; ;(J\Ji!t�¾fofo �ci�.tbi:!.1�hitas) ELEV;,8,';0'.':"riiir:i� •2-XA sorroM•PlATE Wiift:•-X,8" "KNCH.difBOLtS-.@:30". Oc,. �-----�•ANCHORS ----4':CONC,SLAB:Wf 6X6. W1�4XW1.4W,W:F. ---.T-ERMITE-TREATED ,$0ll I 4" • T9PQfSLAB STANDARD DETAIL STANDARD DETAIL WOOD FRAMED 1;4•.,,·�ct SH_E_D_s_--------'-----------..J... ... _-_,,---·=··--,,.,_""""'_'""' _ __,----W,ALL SECTION --1211410-t ------.3/15/os ANGEL THIS DETAIL IS IN COMPLIANCE WITH THE WIND LOAD PROVISIONS FOR 120 MPH OF THE PRESCRIPTIVE DESIGN PARAMETERS ACCORDING TO THE 2017 FLORIDA BUILDING CODE SECTION 1609.1 EXCEPTION NO.2 AND THE AMERICAN WOOD COUNCIL WOOD FRAME CONSTRUCTION MANUAL 2015 EDITION. 'APPROVEO"ROOF!NG--------� MATERIAL SlMP:S.◊N:H;%_¢R'H,1 H_uk�1P��-s cu�·i�/(I_R_tj'$S;: _ {N_a,IIS itjtq Q1)t11'fop:_p·1a�S). i.�;(6'1 P,T FA�GIA,--�.i-,......21.,c2'-••U 1-2 WALL TO ROOF DETAIL _,.,------tx;;4)>r_ijQTfS)r11r PLATE i'{ff!$AL· .. C:ON·N _et;Jci.� _R$P� , , . . -S :r.!Jrtt.{;>:$1NG(E l;!,bt"TO�,(PLA'rE \N/f:Xe"-ANCHO� BOlr-s·:_@'c30"iOCc .THIS DETAIL IS IN COMPLIANCE WITH THE WIND LOAD PROVISIONS FOR 120 MPH OF THE PRESCRIPTIVE DESIGN PARAMETERS ACCORDING TO THE 2017 FLORIDA BUILDING CODE SECTION 1609.1 EXCEPTION NO.2 AND THE AMERICAN WOOD COUNCIL WOOD FRAME CONSTRUCTION MANUAL 2015 EDITION. woo.p FRAMED SHECJS .·: . :1��i-� �� �· $ .✓, .. ,,, "" -,_ ,/('··--.. • •' �c.d�. -!,�:✓:r-��t ... : ; ::: ;�[L:fVAP0It·�RJ{l.E.� .FOUNDATION DETAIL .SPLICE DETAIL FOR #5 BAR . SCALE= ·3/4''=1':(J, OEIM... � STANDARD DETAILS E.NLARGED DETAIL �/15/05 5/8" WOOD STRUCTURAL PANEL ON FLOOR---­NAILED TO FLOOR JOIST AND BLOCKING WITH 8d COMMON NAILS 2"X4" TYPICAL BLOCKING UN DERN EA TH PLYWOOD JOINTS NAILED TO FLOOR JOIST WITH 2-16d COMMON NAILS 24" (f) ' (f) (f) 2 0 (f) � II ' 3,:: (f) � I I I I I I I II I I I I I I I 24" --��-------------H---� 1 I I I i---2"X6" BAND JOIST l===i=f+':=::::::;;:=====i=ili=ill===l N Al LED TO FLOORN� 2"X6" FLOOR JOISTS L= 10'-0" MAX THIS DETAIL IS IN COMPLIANCE WITH THE WIND LOAD PROVISIONS FOR 120 MPH OF THE PRESCRIPTIVE DESIGN PARAMETERS ACCORDING TO THE 2017 FLORIDA BUILDING CODE SECTION 1609.1 EXCEPTION NO.2 AND THE AMERICAN WOOD COUNCIL WOOD FRAME CONSTRUCTION MANUAL 2015 EDITION. OPTION 2 WITH 3- 16d COMMON NAILS. DETAIL NUM8£R: SPEC. NUMBER: WOOD FRAMED SH DS <---------------! 3/8"-1'-0" FLOOR FRAMING PLAN OATS '''"""'"'' 12/14/04 3/15/05 DRAWN BY: APPROVED BY: ANGEL 4'-8"4'-8" Request to add extra skid and space as shown. 3 skids at 4'-8" O.C. (typical) 12" (w) x 12" (d) x 10'-0" gravel trench under each skid. Gravel trench lined with filter fabric to control weeds. Request to add extra skid at spacing shown and gravel bed below each skid. 2" X 4" TYPICAL VERTICAL STUDS @16"0.C. 2" X 6" BAND JOIST -�--­ SECURED TO FLOOR JOISTS WITH 3-16d COMMON NAILS 2" X 4" BOTTOM PLATE---� NAILED TO FLOOR JOISTS WITH TO 2-16d COMMON NAILS 16 FASTENERS 8d COMMON NAILS (H6) STUD TO BAND JOIST SCALE= N.T.S. 1· 2" X 4" VERTICAL STUD 12"0.C. �-�----2" X 6" TYPICAL FLOOR JOISTS 16"0.C. H6 SIMPSON -------------,--�-::-"-IJ TYPICAL CONNECTOR THIS DETAIL IS IN COMPLIANCE WITH THE WIND LOAD PROVISIONS FOR 120 MPH OF THE PRESCRIPTIVE DESIGN PARAMETERS ACCORDING TO THE 2017 FLORIDA BUILDING CODE SECTION 1609.1 EXCEPTION NO.2 AND THE AMERICAN WOOD COUNCIL WOOD FRAME CONSTRUCTION MANUAL 2015 EDITION. STANDARD OETA!L NUMBER: D E T A I L SPCC. """'"' A-6 b==�, --------'"'-"""-! w'OOD FRAMED SHEDS f------------------1 FLOOR FRAMING DAT£: REVISION OATE: 12/14/04 3/15/05 DRAWN fr(; APf'ROVEO m'l ANGEL FULL HEIGHT STUD TYPICAL RSP4"-s::-----------'"'ii�("'--­ STUD TO SINGLE BOTTOM PLATE THIS DETAIL IS IN COMPLIANCE WITH THE WIND LOAD PROVISIONS FOR 120 MPH OF THE PRESCRIPTIVE DESIGN PARAMETERS ACCORDING TO THE 2017 FLORIDA BUILDING CODE SECTION 1609.1 EXCEPTION NO.2 AND THE AMERICAN WOOD COUNCIL WOOD FRAME CONSTRUCTION MANUAL 2015 EDITION. DOUBLE TOP PLATE '----=P!CAL RSP4 CONNECTOR STUD TO DOUBLE TOP PLATE DETAIL NUM6ER1 A-7STANDARD w □□D SHEDS FRAMED w'ALL FRAMING 12/14/04 ORAWN En': APPROVED En': ANGEL 3/15/05 FULL HEIGHT STUD THIS DETAIL IS IN COMPLIANCE WITH THE WIND LOAD PROVISIONS FOR 120 MPH OF THE PRESCRIPTIVE DESIGN PARAMETERS ACCORDING TO THE 2017 FLORIDA BUILDING CODE SECTION 1609.1 EXCEPTION NO.2 AND THE AMERICAN WOOD COUNCIL WOOD FRAME CONSTRUCTION MANUAL 2015 EDITION. l,ce-• 2-2"X4" (OPENING 4'-0" MAX STANDARD DOUBLE TOP PLATE (2) TYPICAL RSP4 STUD TO DOUBLE TOP PLATE DETAIL NUMBER: D E T A I L "" """"'"A 8 w □□D FRAMED SHEDS b------..$l""4 e-------------------""'-'' FRAMING AT DOOR OPENING k.,�m-,----�""'=si,�,�M�m;,------l 12/14/04 3/15/05 DRAWN BY: APPROVED BY: ANGEL FULL HEIGHT STUD DOUBLE HEADER 2 2"X4" (OPENING 4'·0" MAX.) �------DOUBLE TOP PLATE '--------(2) TYPICAL RSP4 STUD TO DOUBLE TOP PLATE (1) TYPICAL RSP4 ....:::'-ss:-------...:i:K STUD TO SINGLE BOTTOM PLATE THIS DETAIL IS IN COMPLIANCE WITH THE WIND LOAD PROVISIONS FOR 120 MPH OF THE PRESCRIPTIVE DESIGN PARAMETERS ACCORDING TO THE 2017 FLORIDA BUILDING CODE SECTION 1609.1 EXCEPTION NO.2 AND THE AMERICAN WOOD COUNCIL WOOD FRAME CONSTRUCTION MANUAL 2015 EDITION. STANDARD D E T A I L SPEC. "°'""' A-9w□□D FRAMED SHEDS b==,-------='1t:1.J 1--------------------, 3/8'=1'-0' FRAMING AT \./INDO\./ OPENING SIDE\./ALL DATE: RE'ASION OATE: 12/14/04 3/15/05 OMWN BYl APPRovt:O 8'1': ANGEL FULL HEIGHT STUD TYPICAL RSP4 STUD TO SINGLE BOTTOM PLATE THIS DETAIL IS IN COMPLIANCE WITH THE WIND LOAD PROVISIONS FOR 120 MPH OF THE PRESCRIPTIVE DESIGN PARAMETERS ACCORDING TO THE 2017 FLORIDA BUILDING CODE SECTION 1609.1 EXCEPTION NO.2 AND THE AMERICAN WOOD COUNCIL WOOD FRAME CONSTRUCTION MANUAL 2015 EDITION. DOUBLE HEADER 2-2"X4" (OPENING 4'-0" MAX,) DOUBLE TOP PLATE USP BP SERIES WASHER OETAll NU�!lffl: A-10w□□D FRAMED SHEDS STANDARD DETAIL s,ec. ,o,SER, I------------------IL_,-,-3-1_s_•-=1-'--o-.-------"S>MJ"-1'OA-no~.----�, .. =sioo=OA�n:�,------j FRAMING AT \./INDO\./ OPENING END\./ALL 12/14/04 3/15/05 CRAWN BY: APPROVED BY: ANGEL Simpson Strong-Tie H1 10 FASTENERS 8d COMMON (H1) ROOF DETAIL N.T.S. 00 00 NAILS r--....-1� �0 0 t-·---../4� 0 Stud to Bottom Plate Simpson Strong-Tie RSP4 8 FASTENERS 8d COMMON NAILS (1)TYPICAL RSP4 STUD SINGLE BOTTOM PLATE N.T.S. THIS DETAIL IS IN COMPLIANCE WITH THE WIND LOAD PROVISIONS FOR 120 MPH OF THE PRESCRIPTIVE DESIGN PARAMETERS ACCORDING TO THE 2017 FLORIDA BUILDING CODE SECTION 1609.1 EXCEPTION NO.2 AND THE AMERICAN WOOD COUNCIL WOOD FRAME CONSTRUCTION MANUAL 2015 EDITION. RAFTERS NOTCHED AT Simpson Strong-Tie H3 8 FASTENERS 8d COMMON NAILS TOP PLATE (BIRD MOUTH CUT) (H3) ROOF DETAIL N.T.S. f-------JO oo oo Stud to Double Top Plates ·Simpson Strong-Tie RSP4 N.T.S. 8 FASTENERS 8d COMMON NAILS (2)TYPICAL RSP4 STUD TO DOUBLE TOP PLATE N.T.S. OUAJL NUMBl:'.R: STANDARD DETAIL SPEC, NUM8ER: A-11 WOOD FRAMED SHEDS f-----------------------,=· N.T.S. CONNECTOR DETAILS DATE: fID/ISION DATE: 12/14/04 3/15/05 DRAWN 8Y: N>PROVEO 8Y: ANGEL 2"X4" RAFTER 2-2"X8" NAILED TOGETHER USING 2-16d COMMON NAILS EVERY 12" TYPICAL H3 CONNECTOR INAL SIZES) RIDGE BEAM OLLAR TIE (COLLAR BEAM) (LOCATED IN UPPER THIRD OF ATTIC SPACE) (2" X 4") "-----��-------=::..,.---2'>-....._ 2"x4" RAFTER TIE LOCATED INTHE LOWER THIRD OF ATTIC SPACE L=1 O' --0" MAX. THIS DETAIL IS IN COMPLIANCE WITH THE WIND LOAD PROVISIONS FOR 120 MPH OF THE PRESCRIPTIVE DESIGN PARAMETERS ACCORDING TO THE 2017 FLORIDA BUILDING CODE SECTION 1609.1 EXCEPTION NO.2 AND THE AMERICAN WOOD COUNCIL WOOD FRAME CONSTRUCTION MANUAL 2015 EDITION. WOOD FRAMED SHEDS DETAIL NUMBER: STANDARD DETAIL A --12 SPEC. NUMBER: SCALE• �--------------f 3/s"-1'-o" RIDGE . BEAM AND ""''12/14/04 RE',lSONDAlE,3/15/05 COLLAR TIE DETAIL OAAWN 8Y: N>PROVEO SY: ANGEL 8d COMMON NAILS OR ( 6" O.C. AT EDGES s 12" O.C. INTERMEDIATE 1 Od BOX NAILS ROOF SHEA THING ----� L= 10'-0" MAX THIS DETAIL IS IN COMPLIANCE WITH THE WIND LOAD PROVISIONS FOR 120 MPH OF THE PRESCRIPTIVE DESIGN PARAMETERS ACCORDING TO THE 2017 FLORIDA BUILDING CODE SECTION 1609.1 EXCEPTION NO.2 AND THE AMERICAN WOOD COUNCIL WOOD FRAME CONSTRUCTION MANUAL 2015 EDITION. �--RAFTERS 16" O.C. X <( 'o I 0 � II 3: RIDGE BOARD OETAIL NUMBER: STANDARD DETAIL SPEC """"'" b.,.,=,-----___,:,r,!M..If--------------f 3/8"-1'-0" WOOD FRAMED SH OS ROOF FRAMING PLAN "'"'12/14/04 """°""'"''311s;os PRAWN BY: L 4' 6" 6" 8' 8' TYPICAL BLOCKING . 16" TYPICAL FLOOR JOISTS FLOOR PANEL 8' ROOF PANEL TYPICAL ROOF RAFTERS TYPICAL-----+--­BLOCKING 4' WOOD FRAM D SHEDS 16" 6" WALL PANEL OEf�L NUld8ER: A-14NAILING PATTERN SPEC. NUldSER: = 1---------------1 3/8"-1 '-0" DATE: REVISION DATE: . WOOD STRUCTURAL PANELS DRAWN BY: N>PROVID BY: Owner/Builder Affidavit ACC23-0023 Notice of Commencement