Loading...
1600 Selva Marina Dr MECH23-0009 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: ATLANTIC BEACH COUNTRY CLUB INC 1600 SELVA MARINA DR ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: BENDER & MODLIN FIRE SPRINKLER 170 -G C COLLEGE DR ORANGE PARK FL 32065 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 172000 0010 SELVA MARINA UNIT 05 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1600 SELVA MARINA DR MECHANICAL COMMERCIAL SEPARATE PLANS OTHER Fire Sprinkler Modification (Fire Prevention)$10000.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT FIRE DEPARTMENT FEE 45500002080800 0 $150.00 FIRE SPRINKLER SYSTEM 455-0000-322-1000 0 $36.40 MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 9/27/2023 PERMIT NUMBER MECH23-0009 ISSUED: 9/27/2023 EXPIRES: 3/25/2024 MECHANICAL COMMERCIAL SEPARATE PLANS PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $245.40 2 of 2Issued Date: 9/27/2023 PERMIT NUMBER MECH23-0009 ISSUED: 9/27/2023 EXPIRES: 3/25/2024 MECHANICAL COMMERCIAL SEPARATE PLANS PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD MECH23-0009 DECK 425 STORAGE 2 423 RESTROOM 422 RESTROOM 421 21 3 A B PLATFORM LIFT 407 DUMB WAITER 410 VESTIBULE 420 UPSTAIRS BAR 424 9' - 11 1/2" 9' - 11 1/2" 9' - 11 1/2" 9' - 11 1/2" 13' - 9" 1. TOTAL AREA PART OF CONTRACT 1ST FLOOR DRY SYSTEM ±1782 SQ FT 2ND FLOOR DRY SYSTEM ±1,674 SQ FT 2. ALL PIPE FOR DRY SYSTEM 1" - 112" SCH 40 BLACK PIPE. 3. ALL PIPE FOR DRY SYSTEM 2" AND UP SCH 10 BLACK PIPE. 4. ALL WORK TO BE PERFORMED AS PER NFPA 13. DRAWING NOTES DENOTES NEW PIPE DENOTES EXISTING PIPE TO REMAIN DENOTES RELOCATED/ADDED FIRE SPRINKLER HEAD DENOTES FIRE SPRINKLER HEAD TO BE RELOCATED DENOTES EXISTING PIPE TO DENOTES FIRE SPRINKLER HEAD TO BE REMOVED DENOTES EXISTING FIRE SPRINKLER HEAD TO REMAIN 27 DENOTES NEW CONNECTION DENOTES HYDRAULIC NODE POINT DENOTES PLUG DENOTES CAP DENOTES FIRE RISER LOCATION SYMBOLS LEGEND BE REMOVED A X R R X DINING 400 KITCHEN 401FIRE RISER 408 PLATFORM LIFT 407 STORAGE 1 412 WATER HEATER CLOSET 405 MEN'S 404 VESTIBULE 403 WOMEN'S 402 21 3 A B COOLER 406 MECHANICAL 409 9' - 11 1/2" 8' - 0" 9' - 11 1/2" 9' - 11 1/2" 9' - 11 1/2" 8' - 6"8' - 6" 8' - 6" 8' - 6" X X X X X X X X X XX XX X X X X X XXXX X X X X FIRE PROTECTION 1ST FLOOR DEMO PLAN FIRE PROTECTION 1ST FLOOR PLAN DINING 400 KITCHEN 401FIRE RISER 408 PLATFORM LIFT 407 STORAGE 1 412 WATER HEATER CLOSET 405 MEN'S 404 VESTIBULE 403 WOMEN'S 402 21 3 A B COOLER 406 MECHANICAL 409 9' - 11 1/2" 8' - 0" 9' - 11 1/2" 9' - 11 1/2" 9' - 11 1/2" 8' - 6"8' - 6" 8' - 6" 8' - 6" X X X X X X X X X X X X X X X XXXX X X X STORAGE 2 413 FIRE PROTECTION 2ND FLOOR PLAN DECK 425 STORAGE 2 423 RESTROOM 422 RESTROOM 421 21 3 A B PLATFORM LIFT 407 DUMB WAITER 410 VESTIBULE 420 UPSTAIRS BAR 424 9' - 11 1/2" 9' - 11 1/2" 9' - 11 1/2" 9' - 11 1/2" 13' - 9" X X X X X X X 2021 2223 24 1 2 3 4 5 6 7 898S 252627 32 31 30 29S 28 21S 4S 25S26S27S 6S 29 106 100D 100101 101D 102 102D103D 107D 106D 105 105D 110D 110 104104D 108 108D 107 109 109D 99D 99 98D 98 97D 97 11 1213 13S 20S 28S FIRE PROTECTION 2ND FLOOR DEMO PLAN BM 24x36HFIRE SPRINKLER, INC. 1. TOTAL AREA PART OF CONTRACT 1ST FLOOR DRY SYSTEM ±1782 SQ FT 2ND FLOOR DRY SYSTEM ±1,674 SQ FT 2. ALL PIPE FOR DRY SYSTEM 1" - 112" SCH 40 BLACK PIPE. 3. ALL PIPE FOR DRY SYSTEM 2" AND UP SCH 10 BLACK PIPE. 4. ALL WORK TO BE PERFORMED AS PER NFPA 13. DRAWING NOTES DENOTES NEW PIPE DENOTES EXISTING PIPE TO REMAIN DENOTES RELOCATED/ADDED FIRE SPRINKLER HEAD DENOTES FIRE SPRINKLER HEAD TO BE RELOCATED DENOTES EXISTING PIPE TO DENOTES FIRE SPRINKLER HEAD TO BE REMOVED DENOTES EXISTING FIRE SPRINKLER HEAD TO REMAIN 27 DENOTES NEW CONNECTION DENOTES HYDRAULIC NODE POINT DENOTES PLUG DENOTES CAP DENOTES FIRE RISER LOCATION SYMBOLS LEGEND BE REMOVED A X R R X ATLAN T I C B E A C H D R I V E S.= 0 . 3 5 % PETE'S TURN 4" DCDA BACKFLOW PREVENTER 8" X 4" TAPPING SLEEVE AND TAPPING VALVE EXISTING STORM YARD DRAIN (SEE NOTE 3)UG1 BOR BKFL UG2 TEST FIRE PROTECTION SITE PLAN (FOR HYRAULIC REFERENCE ONLY) RETURN BEND DETAIL MAXIMUM DISTANCE BETWEEN HANGERS HORIZ. WOOD SCREW FIRE PROTECTION GENERAL NOTES VERTICAL WOOD SCREW FLOW TEST DATA FIRE RISER DETAIL TOR BOR BM 24x36HFIRE SPRINKLER, INC. As the leading supplier of steel sprinkler pipe, we understand that there are no second chances in fire suppression. You need products of enduring quality and exceptional strength—plus reliable service. You need Bull Moose. SCHEDULE 10 & 40 ADVANTAGES: • UL listed (US & Canada) and FM approved • ASTM A135 and A795 Type E, Grade A Certified • Complies with NFPA-13, 13R and 14 • Industry-leading hydraulic characteristics • CRR of 1.0 and greater • All pipe NDT weld tested OTHER BENEFITS/SERVICES: • We have the most stocking locations in the industry, for best delivery and availability • Plain end or roll groove • Eddy Guard II™ bacterial-resistant internal coating • Custom length options • Hot dipped galvanization • Reddi-Pipe® red or black pipe eliminates field painting • Compatible for use in wet, dry, preaction and deluge sprinkler systems • The only maker with EPDs (to help earn LEED points). Always ready to protect your most valuable assets. SCHEDULE 10 & 40 Exclusive maker of Reddi-Pipe® RED OR BLACK PAINTED PIPE. 800.325.4467 sales@BullMooseIndustries.com BullMooseTube.com Nominal Pipe Size (Inches)1"1-1/4" 1-1/2"2"2-1/2"3"4"6"8" O.D. (in)1.315 1.660 1.900 2.375 2.875 3.500 4.500 6.625 8.625 I.D. (in)1.097 1.442 1.682 2.157 2.635 3.260 4.260 6.357 8.249 Empty Weight (lb/ft)1.410 1.810 2.090 2.640 3.530 4.340 5.620 9.290 16.940 Water Filled Weight (lb/ft)1.820 2.518 3.053 4.223 5.893 7.957 11.796 23.038 40.086 C.R.R.15.27 9.91 7.76 6.27 4.92 3.54 2.50 1.158 1.805 Pieces per Lift 91 61 61 37 30 19 19 10 7 Lift Weight (lbs) 21' lengths 2,695 2,319 2,677 2,051 2,224 1,732 2,242 1,951 2,490 Lift Weight (lbs) 24' lengths 3,079 2,650 3,060 2,344 2,542 1,979 2,563 2,230 2,848 Lift Weight (lbs) 25' lengths 3,208 2,760 3,187 2,442 2,648 2,062 2,670SCHEDULE 10NPS (In.)1"1-1/4" 1-1/2"2"2-1/2"3"4" 1.315 1.660 1.900 2.375 2.875 3.500 4.500 1.049 1.380 1.610 2.067 2.469 3.068 4.026 1.680 2.270 2.720 3.660 5.800 7.580 10.800 2.055 2.918 3.602 5.114 7.875 10.783 16.316 1.00 1.00 1.00 1.00 1.00 1.00 1.00 70 51 44 30 30 19 19 2,470 2,431 2,513 2,306 3,654 3,024 4,309 2,822 2,778 2,872 2,635 4,176 3,456 4,925 2,940 2,894 2,992 2,745 4,350 3,601 5,130SCHEDULE 40Bull Moose Fire Sprinkler Pipe Product Information Grooved End Fittings Rev.20230502 Grooved End Fittings For pressure rating, listing, and approval information, refer to Data Sheet B-42 or visit SHURJOINT website, www.shurjoint.com for details or contact your SHURJOINT Representative Shurjoint ductile iron grooved-end fittings are made of ductile iron per ASTM A536 Gr. 65-45-12. C-E dimensions are manufacturer’s standard. Shurjoint wrought steel grooved-end fittings are available from 10” (250 mm) through 24” (600 mm) pipe sizes in a variety of styles. Fittings are fabricated with the carbon steel pipe to ASTM A234 Gr. WPB, standard weight (0.375” or 9.5 mm), or segmentally welded carbon steel of the same or equivalent grade. C-E dimensions conform to ANSI B16.9. Other styles not listed are available upon request. Fitting pressure ratings are equivalent to the pressure ratings of the coupling used to install them. Coupling pressure ratings are pipe wall thickness dependent. material specification  Fitting Body: Ductile Iron castings to ASTM A536, Gr. 65-45-12, min. tensile strength 65,000 psi (448 MPa). Fabricated with the carbon steel pipe to ASTM A234 Gr. WPB, standard weight (0.375” or 9.5 mm), or segmentally welded carbon steel of the same or equivalent grade.  Surface Finish: Orange color painted or red RAL3000 color painted. o Hot dip galvanized (optional). o Epoxy coated in red RAL3000 or other colors (optional) Grooved End Fittings Rev.20230502 Grooved End Fittings Models 901 / 903 Nominal Pipe Size Pipe O.D. 901 SR 90° Elbow 903 SR Straight Tee C-E Weight C-E Weight in in in lbs in lbs mm mm mm kg mm kg 2 2.375 2.75 1.5 2.75 2.2 50 60.3 70 0.7 70 1.0 2½ 2.875 3.00 2.0 3.00 2.9 65 73.0 76 0.9 76 1.3 76.1 3.000 3.00 2.5 3.00 2.9 76.1 76 1.1 76 1.3 3 3.500 3.38 3.1 3.38 4.4 80 88.9 86 1.4 86 2.0 4 4.500 4.00 4.9 4.00 7.9 100 114.3 102 2.2 102 3.6 139.7 5.500 4.88 7.9 4.88 11.1 139.7 124 3.6 124 5.1 5 5.563 4.88 7.9 4.88 10.1 125 141.3 124 3.6 124 4.6 165.1 6.500 5.50 12.9 5.50 16.5 165.1 140 5.9 140 7.5 6 6.625 5.50 12.9 5.50 17.2 150 168.3 140 5.9 140 7.8 8 8.625 6.94 23.4 6.94 36.3 200 219.1 176 10.6 176 16.5 Grooved End Fittings Rev.20230502 Grooved End Fittings MODEL 7110 / 7111 / 7112 / 7113 ELBOWS Normal Size Pipe O.D. #7110 90° Elbows #7111 45° Elbows #7112 22.5° Elbows #7113 11.25° Elbows C-E weight C-E weight C-E weight C-E weight in in in lbs in lbs in lbs in lbs mm mm mm kg mm kg mm kg mm kg 1 1.315 2.25 0.7 1.75 0.5 -- -- 1.38 0.4 25 33.4 57 0.3 45 0.2 -- -- 35 0.2 1¼ 1.660 2.75 1.1 1.75 0.7 1.75 0.7 1.38 0.7 32 42.2 70 0.5 45 0.3 45 0.3 35 0.3 1½ 1.900 2.75 1.3 1.75 0.9 1.75 1.1 1.38 0.7 40 48.3 70 0.6 45 0.4 45 0.5 35 0.3 2 2.375 3.25 2.0 2.00 1.5 1.88 1.6 1.38 1.0 50 60.3 83 0.9 51 0.7 48 0.7 35 0.4 2½ 2.875 3.75 2.6 2.25 2.1 2.01 2.6 1.50 1.6 65 73.0 95 1.2 57 0.9 51 1.2 38 0.7 76.1 3.000 3.75 3.1 2.25 2.1 2.01 2.5 1.50 1.7 76.1 95 1.4 57 0.9 51 1.1 38 0.8 3 3.500 4.25 4.3 2.50 2.9 2.25 3.1 1.50 1.8 80 88.9 108 2.0 64 1.3 57 1.4 38 0.8 101.6 4.000 4.50 5.5 -- -- -- -- -- -- 101.6 114 2.5 -- -- -- -- -- -- 108.0 4.250 5.00 5.5 3.00 4.4 -- -- -- -- 108.0 127 2.5 76 2.0 -- -- -- -- 4 4.500 5.00 6.9 3.00 4.4 2.88 4.4 1.75 2.2 100 114.3 127 3.1 76 2.0 73 2.0 45 1.0 133.0 5.250 5.50 9.0 3.25 5.9 -- -- -- -- 133.0 140 4.1 83 2.7 -- -- -- -- 139.7 5.500 5.50 9.5 3.25 6.4 2.88 6.5 2.00 4.5 139.7 140 4.3 83 2.9 73 2.9 51 2.0 5 5.563 5.50 11.0 3.25 6.6 2.88 6.8 2.00 4.5 125 141.3 140 5.0 83 3.0 73 3.1 51 2.1 90o 45o 22½o 11¼o Grooved End Fittings Rev.20230502 Grooved End Fittings MODEL 7110 / 7111 / 7112 / 7113 ELBOWS Normal Size Pipe O.D. #7110 90° Elbows #7111 45° Elbows #7112 22.5° Elbows #7113 11.25° Elbows C-E weight C-E weight C-E weight C-E weight in in in lbs in lbs in lbs in lbs mm mm mm kg mm kg mm kg mm kg 159.0 6.250 6.50 13.2 3.50 8.4 -- -- -- -- 159.0 165 6.0 89 3.8 -- -- -- -- 165.1 6.500 6.50 12.5 3.50 8.9 3.12 10.7 2.00 5.5 165.1 165 5.7 89 4.0 79 4.9 51 2.5 6 6.625 6.50 12.8 3.50 8.9 3.12 9.3 2.00 5.5 150 168.3 165 5.8 89 4.0 79 4.2 51 2.5 8 8.625 7.75 28.7 4.25 19.0 3.88 17.8 2.00 10.1 200 219.1 197 13.0 108 8.6 98 8.1 51 4.6 10 10.750 9.00 53.1 4.75 34.2 4.38 39.0 2.13 22.1 250 273.0 229 24.1 121 15.5 111 17.7 54 10.0 12 12.750 10.00 81.0 5.25 49.5 4.88 43.0 2.25 27.3 300 323.9 254 36.7 133 22.5 124 19.5 57 12.4 200 JIS 8.516 7.75 27.2 4.25 18.5 3.88 13.9 2.00 9.3 216.3 197 12.4 108 8.4 98 6.3 51 4.2 250 JIS 10.528 9.00 52.8 4.75 34.2 4.38 22.5 2.13 22.1 267.4 229 24.0 121 15.5 111 10.2 54 10.0 300 JIS 12.539 10.00 77.0 5.25 49.5 4.88 33.7 2.25 27.3 318.5 254 35.0 133 22.5 124 15.3 57 12.4 Grooved End Fittings Rev.20230502 Grooved End Fittings 7120 Tee 7135 Cross Model 7120 TEE / 7135 CROSS Nominal Size Pipe O.D. #7120 Tee #7135 Cross C - E Weight C-LE Weight in in in lbs in lbs mm mm mm kg mm kg 1 1.315 2.25 0.9 2.25 --- 25 33.4 57 0.4 57 --- 1¼ 1.660 2.75 1.5 2.75 --- 32 42.2 70 0.7 70 --- 1½ 1.900 2.75 2.0 2.75 --- 40 48.3 70 0.9 70 --- 2 2.375 3.25 2.9 3.25 2.7 50 60.3 83 1.3 83 1.2 2½ 2.875 3.75 4.8 3.75 6.6 65 73.0 95 2.2 95 3.0 76.1 3.000 3.75 5.1 3.75 6.6 76.1 95 2.3 95 3.0 3 3.500 4.25 6.8 4.25 6.8 80 88.9 108 3.1 108 3.1 4 4.500 5.00 9.9 5.00 11.5 100 114.3 127 4.5 127 5.2 108.0 4.250 5.00 9.0 --- --- 108.0 127 4.1 --- --- 133.0 5.250 5.50 13.2 --- --- 133.0 140 6.0 --- --- 139.7 5.500 5.50 14.3 5.50 13.0 139.7 140 6.5 140 5.9 5 5.563 5.50 14.3 5.50 13.0 125 141.3 140 6.5 140 5.9 159.0 6.250 6.50 18.9 --- --- 159.0 165 8.6 --- --- Grooved End Fittings Rev.20230502 Grooved End Fittings * Segmentally welded carbon steel fitting with roll groove. Sold as “W” series item. Model 7120 TEE / 7135 CROSS Nominal Size Pipe O.D. #7120 Tee #7135 Cross C - E Weight C-LE Weight in in in lbs in lbs mm mm mm kg mm kg 165.1 6.500 6.50 21.7 6.50 32.0 165.1 165 9.9 165 14.5 6 6.625 6.50 22.0 6.50 32.0 150 168.3 165 10.0 165 14.5 8 8.625 7.75 44.0 7.75 44.1 200 219.1 197 20.0 197 20.0 10 10.750 9.00 68.2 8.50* 72.7 250 273.0 229 31.0 216 33.0 12 12.750 10.00 96.7 10.00* 96.9 300 323.9 254 43.9 254 44.0 200 JIS 8.516 7.75 44.0 7.75 44.1 216.3 197 20.0 197 20.0 250 JIS 10.528 9.00 68.2 --- --- 267.4 229 31.0 --- --- 300 JIS 12.539 10.00 96.7 --- --- 318.5 254 43.9 --- --- 14* 14.000 11.00 110.2 11.00 121.0 350 355.6 279.4 50.0 279 54.9 16* 16.000 12.00 145.4 12.00 146.4 400 406.4 304.8 66.1 305 66.4 18* 18.000 13.50 169.8 13.50 185.4 450 457.2 342.9 77.0 343 84.1 20* 20.000 15.00 209.4 15.00 229.1 500 508.0 381.0 95.0 381 103.9 22* 22.000 16.50 277.2 --- --- 550 558.8 419.1 126.0 --- --- 24* 24.000 17.00 267.9 17.00 298.7 600 609.6 431.8 121.5 432 135.5 Grooved End Fittings Rev.20230502 Grooved End Fittings 1”~12” Models 7160 End Cap / 7160P End Cap with Plug Nominal Pipe Size Pipe O.D. 7160 End Cap 7160P Plug Size E-E weight in in in lbs in mm mm mm kgs mm 1 1.315 0.87 0.2 --- 25 33.4 22 0.1 --- 1¼ 1.660 1.00 0.3 --- 32 42.2 25 0.2 --- 1½ 1.900 1.00 0.4 --- 40 48.3 25 0.2 --- 2 2.375 1.00 0.7 ½ 50 60.3 25 0.3 15 2½ 2.875 1.00 0.9 ½ 65 73.0 25 0.4 15 76.1 3.000 1.00 0.9 ½ 76.1 25 0.4 15 3 3.500 1.00 1.5 ½ 80 88.9 25 0.7 15 108.0 4.250 1.00 2.4 --- 108.0 25 1.1 --- 4 4.500 1.00 2.2 1 100 114.3 25 1.0 25 133.0 5.250 1.00 3.7 --- 133.0 25 1.7 --- 139.7 5.500 1.00 3.7 1 139.7 25 1.7 25 5 5.563 1.00 3.7 1 125 141.3 25 1.7 25 159.0 6.250 1.00 5.1 --- 159.0 25 2.3 --- 165.1 6.500 1.00 6.0 1 165.1 25 2.7 25 Grooved End Fittings Rev.20230502 Grooved End Fittings * Segmentally welded carbon steel fitting with roll groove. Sold as “W” series item. Models 7160 End Cap / 7160P End Cap with Plug Nominal Pipe Size Pipe O.D. 7160 End Cap 7160P Plug Size E-E weight in in in lbs in mm mm mm kgs mm 6 6.625 1.00 6.0 1 150 168.3 25 2.7 25 8 8.625 1.18 10.1 1½ 200 219.1 30 4.6 40 10 10.750 1.25 15.4 1½ 250 273.0 32 7.0 40 12 12.750 1.25 22.0 1½ 300 323.9 32 10.0 40 200 JIS 8.516 1.18 10.1 --- 216.3 30 4.6 --- 250 JIS 10.528 1.25 15.4 --- 267.4 32 7.0 --- 300 JIS 12.539 1.25 22.0 --- 318.5 32 10.0 --- 14* 14.000 6.50 35.0 --- 350 355.6 165.0 15.9 --- 16* 16.000 7.00 44.0 --- 400 406.4 178.0 20.0 --- 18* 18.000 8.00 56.1 --- 450 457.2 203.0 25.5 --- 20* 20.000 9.00 70.0 --- 500 508.0 229.0 31.8 --- 22* 22.000 10.00 85.4 --- 550 558.8 254.0 38.8 --- 24* 24.000 10.50 99.2 --- 600 609.6 267.0 45.1 --- • • o • o o • • • • • • • • Project InformatIon :aPProval Stam P: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-00 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material Specification S Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. reducing coupling Nominal Size Anvil Item Number Universal Number Max. Working Pressure DimensionsA Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 x 1⁄2 840010755 DRC031 500 1.69 0.39 25 x 15 3450 42.92 0.18 1 x 3⁄4 840010763 DRC032 500 1.69 0.53 25 x 20 3450 42.92 0.24 A reducing couplling Ductile Iron PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-5.16 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.14 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS s Pressure - Temperature Ratings in accordance with ASME B16.3 Class 150 FIG. 3388 Cored Plug For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A FIGURE 3388 - CORED PLUG Nominal Size Maximum Working Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1⁄2*500 0.94 0.10 15 3450 23.87 0.05 3⁄4 500 1.07 0.17 20 3450 27.17 0.08 1 500 1.25 0.28 25 3450 31.75 0.13 11⁄4 500 1.36 0.44 32 3450 34.54 0.20 11⁄2 500 1.45 0.62 40 3450 36.83 0.28 2 500 1.56 0.91 50 3450 39.62 0.41 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as Solid Plug. Project InformatIon :aPProval Stam P: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-003 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material Specification S Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. Straight tee Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. Each A B In. (mm)PSI (kPa)In. (mm)In. (mm)Lbs. (kg) 1 840003164 DT333 500 1.50 1.50 0.85 25 3450 38.10 38.10 0.39 11⁄4 840003172 DT444 500 1.75 1.75 1.22 32 3450 44.45 44.45 0.55 11⁄2 840003180 DT555 500 1.94 1.94 1.55 40 3450 49.27 49.27 0.70 2 840003198 DT666 500 2.25 2.25 2.45 50 3450 57.15 57.15 1.11 B AA Straight tee Ductile Iron Project InformatIon :aPProval Stam P: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-004 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material Specification S Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. reducing tee Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. EachABC In. (mm)PSI (kPa)In. (mm)In. (mm)In. (mm)Lbs.(kg) 11⁄2 x 11⁄4 x 1 840004428 DT543 500 1.65 1.58 1.80 1.2540 x 32 x 25 3450 41.91 40.13 45.72 0.5711⁄2 x 11⁄4 x 2 840004436 DT546 500 2.16 2.10 2.02 1.9040 x 32 x 50 3450 54.86 53.34 51.30 0.8611⁄2 x 11⁄2 x 1⁄2 840004444 DT551 500 1.41 1.41 1.16 1.1540 x 40 x 15 3450 35.81 35.81 29.46 0.5211⁄2 x 11⁄2 x 3⁄4 840004451 DT552 500 1.52 1.52 1.75 1.2440 x 40 x 20 3450 38.61 38.61 44.45 0.5611⁄2 x 11⁄2 x 1 840004469 DT553 500 1.65 1.65 1.80 1.3040 x 40 x 25 3450 41.91 41.91 45.72 0.5911⁄2 x 11⁄2 x 11⁄4 840004477 DT554 500 1.82 1.82 1.88 1.4840 x 40 x 32 3450 46.23 46.23 47.75 0.6711⁄2 x 11⁄2 x 2 840004485 DT556 500 2.16 2.16 2.02 1.9840 x 40 x 50 3450 54.86 54.86 51.30 0.902 x 1 x 2 840004493 DT636 500 2.25 2.02 2.25 2.1550 x 25 x 50 3450 57.15 51.31 57.15 0.982 x 11⁄4 x 2 840004501 DT646 500 2.25 2.10 2.25 2.3050 x 32 x 50 3450 57.15 53.34 57.15 1.042 x 11⁄2 x 1⁄2 840004519 DT651 500 1.49 1.41 1.88 1.5050 x 40 x 15 3450 37.85 35.81 47.75 0.682 x 11⁄2 x 3⁄4 840004527 DT652 500 1.60 1.52 1.97 1.6250 x 40 x 20 3450 40.64 38.61 50.04 0.732 x 11⁄2 x 1 840004535 DT653 500 1.73 1.65 2.02 1.6450 x 40 x 25 3450 43.94 41.91 51.31 0.742 x 11⁄2 x 11⁄4 840004543 DT654 500 1.90 1.82 2.10 1.8050 x 40 x 32 3450 48.26 46.23 53.34 0.822 x 11⁄2 x 11⁄2 840004550 DT655 500 2.02 1.94 2.16 2.0050 x 40 x 40 3450 51.31 49.28 54.86 0.912 x 11⁄2 x 2 840004568 DT656 500 2.25 2.16 2.25 2.3550 x 40 x 50 3450 57.15 54.86 57.15 1.072 x 2 x 1⁄2 840004576 DT661 500 1.49 1.49 1.88 1.6050 x 50 x 15 3450 37.85 37.85 47.75 0.732 x 2 x 3⁄4 840004584 DT662 500 1.60 1.60 1.97 1.6850 x 50 x 20 3450 40.64 40.64 50.04 0.762 x 2 x 1 840004592 DT663 500 1.73 1.73 2.02 1.8550 x 50 x 25 3450 43.94 43.94 51.31 0.842 x 2 x 11⁄4 840004600 DT664 500 1.90 1.90 2.10 2.0450 x 50 x 32 3450 44.45 42.42 44.45 0.932 x 2 x 11⁄2 840004618 DT665 500 2.02 2.02 2.16 2.1850 x 50 x 40 3450 44.45 42.42 44.45 0.992 x 2 x 21⁄2 -DT667 500 2.60 2.60 2.39 3.6150 x 50 x 65 3450 44.45 42.42 44.45 1.6421⁄2 x 2 x 3⁄4 -DT762 500 1.74 1.60 2.32 2.2865 x 50 x 20 3450 44.45 42.42 44.45 1.03 reducing tee Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. EachABC In. (mm)PSI (kPa)In. (mm)In. (mm)In. (mm)Lbs.(kg) 1 x 1⁄2 x 1 840004196 DT313 500 1.50 1.36 1.50 0.6425 x 15 x 25 3450 38.10 34.54 38.10 0.291 x 3⁄4 x 1 840004204 DT323 500 1.50 1.45 1.50 0.7325 x 20 x 25 3450 38.10 36.83 38.10 0.331 x 1 x 1⁄2 840004212 DT331 500 1.26 1.26 1.36 0.7125 x 25 x 15 3450 32.00 32.00 34.54 0.321 x 1 x 3⁄4 840004220 DT332 500 1.37 1.37 1.45 0.7625 x 25 x 20 3450 34.80 34.80 36.83 0.341 x 1 x 11⁄4 840004238 DT334 500 1.67 1.67 1.58 0.9825 x 25 x 32 3450 42.41 42.41 40.13 0.441 x 1 x 11⁄2 840004246 DT335 500 1.80 1.80 1.65 1.1625 x 25 x 40 3450 45.72 45.72 41.91 0.5311⁄4 x 1 x 1⁄2 840004253 DT431 500 1.34 1.26 1.53 0.8232 x 25 x 15 3450 34.04 32.00 38.86 0.3711⁄4 x 1 x 3⁄4 840004261 DT432 500 1.45 1.37 1.62 0.9032 x 25 x 20 3450 36.83 34.80 41.15 0.4111⁄4 x 1 x 1 840004279 DT433 500 1.58 1.50 1.67 1.0032 x 25 x 25 3450 40.13 38.10 42.42 0.4511⁄4 x 1 x 11⁄4 840004287 DT434 500 1.75 1.67 1.75 1.0832 x 25 x 32 3450 44.45 42.42 44.45 0.4911⁄4 x 1 x 11⁄2 840004295 DT435 500 1.88 1.80 1.82 1.4232 x 25 x 40 3450 47.75 45.72 46.22 0.6411⁄4 x 11⁄4 x 1⁄2 840004303 DT441 500 1.34 1.34 1.53 0.8632 x 32 x 15 3450 34.04 34.04 38.86 0.3911⁄4 x 11⁄4 x 3⁄4 840004311 DT442 500 1.45 1.45 1.62 0.9232 x 32 x 20 3450 36.83 36.83 41.15 0.4211⁄4 x 11⁄4 x 1 840004329 DT443 500 1.58 1.58 1.67 0.9532 x 32 x 25 3450 40.13 40.13 42.42 0.4311⁄4 x 11⁄4 x 11⁄2 840004337 DT445 500 1.88 1.88 1.82 1.4532 x 32 x 40 3450 47.75 47.75 46.22 0.6611⁄4 x 11⁄4 x 2 840004345 DT446 500 2.10 2.10 1.90 1.7532 x 32 x 50 3450 53.34 53.34 48.26 0.7911⁄2 x 1 x 1⁄2 840004352 DT531 500 1.41 1.34 1.66 0.9540 x 25 x 15 3450 35.81 34.04 42.16 0.4311⁄2 x 1 x 3⁄4 840004360 DT532 500 1.52 1.37 1.75 1.1440 x 25 x 20 3450 38.61 34.80 44.45 0.5211⁄2 x 1 x 1 840004378 DT533 500 1.65 1.50 1.80 1.1740 x 25 x 25 3450 41.91 38.10 45.72 0.5311⁄2 x 1 x 11⁄4 840004386 DT534 500 1.82 1.67 1.88 1.3440 x 25 x 32 3450 46.23 42.42 47.75 0.6111⁄2 x 1 x 11⁄2 840004394 DT535 500 1.94 1.80 1.94 1.4540 x 25 x 40 3450 49.28 45.72 49.28 0.6611⁄2 x11⁄4 x 1⁄2 840004402 DT541 500 1.41 1.34 1.66 1.0540 x 32 x 15 3450 35.81 34.04 42.16 0.4811⁄2 x11⁄4 x 3⁄4 840004410 DT542 500 1.52 1.45 1.75 1.1540 x 32 x 20 3450 38.61 36.83 44.45 0.52 C BA reducing tee Ductile Iron Project InformatIon :aPProval Stam P: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-000 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material Specification S Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. 90° elbow Nominal Size Anvil ItemNumber Universal Number Max. Working Pressure Dimensions- In.(mm)Approx. Wt. Each A B In. (mm)PSI (kPa)In. (mm)In. (mm)Lbs. (kg) 1 840000004 DB90033 500 1.50 1.50 0.62 20 3450 38.10 38.10 0.28 11⁄4 840000012 DB90044 500 1.75 1.75 0.90 32 3450 44.45 44.45 0.41 11⁄2 840000020 DB90055 500 1.94 1.94 1.20 40 3450 49.276 49.276 0.54 2 840000038 DB90066 500 2.25 2.25 1.85 50 3450 57.15 57.15 0.84 B A 90° elbow Ductile Iron Project InformatIon :aPProval Stam P: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-002 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material Specification S Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. reducing 90° elbow Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. Each A B In. (mm)PSI (kPa)In. (mm)In. (mm)Lbs. (kg) 1 x 1⁄2 840001036 DB90031 500 1.26 1.36 0.44 25 x 15 3450 32.00 34.54 0.20 1 x 3⁄4 840001044 DB90032 500 1.37 1.45 0.52 25 x 20 3450 34.79 36.83 0.24 11⁄4 x 1⁄2 840001051 DB90041 500 1.34 1.53 0.64 32 x 15 34550 34.03 38.86 0.29 11⁄4 x 3⁄4 840001069 DB90042 500 1.45 1.62 0.72 32 x 20 3450 36.83 41.14 0.33 11⁄4 x 1 840001077 DB90043 500 1.58 1.67 0.75 32 x 25 3450 40.13 42.41 0.34 11⁄2 x 1 840001085 DB90053 500 1.65 1.80 0.92 40 x 25 3450 41.91 45.72 0.42 11⁄2 x 11⁄4 840001093 DB90054 500 1.82 1.88 1.08 40 x 32 3450 46.22 47.75 0.49 2 x 1⁄2 840001101 DB90061 500 1.49 1.88 1.08 50 x 15 3450 37.84 47.75 0.49 2 x 3⁄4 840001119 DB90062 500 1.60 1.97 1.24 50 x 20 3450 40.64 50.03 0.56 2 x 1 840001127 DB90063 500 1.73 2.02 1.40 50 x 25 3450 43.94 51.30 0.64 2 x 11⁄4 840001135 DB90064 500 1.90 2.10 1.52 50 x 32 3450 48.26 53.34 0.70 2 x 11⁄2 840001143 DB90065 500 2.02 2.16 1.65 50 x 40 3450 51.30 54.86 0.75 A B reducing 90° elbow Ductile Iron Project InformatIon :aPProval Stam P: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-00 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material Specification S Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. 45° elbow Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions-Approx. Wt. Each A B In. (mm)PSI (kPa)In. (mm)In. (mm)Lbs. (kg) 1 840002133 DB45033 500 1.12 1.12 0.46 25 3450 28.44 28.44 0.21 11⁄4 840002141 DB45044 500 1.29 1.29 0.73 32 3450 32.76 32.76 0.33 11⁄2 840002158 DB45055 500 1.43 1.43 0.92 40 3450 36.32 36.32 0.42 2 840002166 DB45066 500 1.68 1.68 1.50 50 3450 42.67 42.67 0.68 A B45° elbow Ductile Iron Project InformatIon :aPProval Stam P: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-00 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material Specification S Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. capS Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 840005615 DCP003 500 1.16 0.32 25 3450 29.46 0.15 11⁄4 840005623 DCP004 500 1.28 0.43 32 3450 32.51 0.20 11⁄2 840005631 DCP005 500 1.33 0.60 40 3450 33.78 0.27 2 840005649 DCP006 500 1.45 0.91 50 3450 36.83 0.41 A cap Ductile Iron Project InformatIon :aPProval Stam P: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-0020 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material Specification S Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. bu ShingS Nominal Size Anvil Item Number Universal Number Dimensions Style Approx. Wt. Each A B C In. (mm)In. (mm)In. (mm)In. (mm)Lbs. (kg) 1 x 1⁄2 840600001 DBUSH31 0.75 0.25 1.42 Outside 0.22 25 x 15 19.05 6.35 36.06 0.10 1 x 3⁄4 840600019 DBUSH32 0.75 0.25 1.42 Outside 0.17 25 x 20 19.05 6.35 36.06 0.08 11⁄4 x 1 840600027 DBUSH43 0.80 0.28 1.76 Outside 0.28 32 x 25 20.32 7.11 44.70 0.13 11⁄2 x 1 840600035 DBUSH53 0.83 0.31 2.00 Outside 0.45 40 x 25 21.08 7.874 50.80 0.20 11⁄2 x 11⁄4 840600043 DBUSH54 0.83 0.31 2.00 Outside 0.30 40 x 32 21.08 7.874 50.80 0.14 2 x 1 840600050 DBUSH63 0.88 0.41 1.95 Inside 0.67 50 x 25 22.35 10.414 49.53 0.30 2 x 11⁄4 840600068 DBUSH64 0.88 0.34 2.48 Outside 0.73 50 x 32 22.35 8.636 62.99 0.33 2 x 11⁄2 840600076 DBUSH65 0.88 0.34 2.48 Outside 0.61 50 x 40 22.35 8.636 62.99 0.28 A B C A B C Inside Head Outside Head buShingS Ductile Iron MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK327 (K4.2) TECHNICAL DATA Page 1 of 3 Form No. F_061514 21.03.05 Rev 21.1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. 1. DESCRIPTION The Viking Microfast® Quick Response Upright Sprinkler VK327 is a small, thermosensitive, glass-bulb spray sprinkler available in several different finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are listed/approved as indicated in the Approval Chart(s). 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV Refer to Approval Chart(s) and Design Criteria for cULus Listing requirements that must be followed. 3. TECHNICAL DATASpecifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatic rating: 500 psi (34.5 bar) Thread size: 1/2” NPT, 15 mm BSPT Nominal K-Factor: 4.2 U.S. (57 metric**) Glass-bulb fluid temperature rating: -65 °F (-55 °C) Overall Length: 2-1/4” (58 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Covered by the following US Patent No.: 4,831,870Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C23000 or Copper UNS-C19500 Bushing: Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw-ENT Plated, Pip Cap-ENT CoatedOrdering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Upright Sprinkler VK327 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffixes: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B and ENT = JN Temperature Suffixes: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, and 286 F° (141 °C) = G For example, sprinkler VK327 with a 1/2” NPT thread, Brass finish and a 155 °F (68 °C) temperature rating = Part No. 06719BAB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrench: Standard Wrench: Part No. 21475M/B (available since 2017) Sprinkler Cabinets:A. Six-head capacity: Part No. 01724A (available since 1971)B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATIONRefer to appropriate NFPA Installation Standards. Replaces Form F_061514 Rev 20.1 (Removed bushed part numbers) MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK327 (K4.2) TECHNICAL DATA Page 2 of 3 Form No. F_061514 21.03.05 Rev 21.1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCERefer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast® Quick Response Upright Sprinkler VK327 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEEFor details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary 135 °F (57 °C)100 °F (38 °C)Orange Ordinary 155 °F (68 °C)100 °F (38 °C)Red Intermediate 175 °F (79 °C)150 °F (65 °C)Yellow Intermediate 200 °F (93 °C)150 °F (65 °C)Green High 286 °F (141 °C)225 °F (107 °C)Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester and ENT3,4 Corrosion-Resistant Coatings: White Polyester, Black Polyester and ENT3,4 Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart(s). These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfac-es only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. 4 cULus Listed as corrosion resistant. Figure 1: Standard Sprinkler Wrench 21475M/B Protective Sprinkler Cap Wrench Flat MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK327 (K4.2) TECHNICAL DATA Page 3 of 3 Form No. F_061514 21.03.05 Rev 21.1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Approval Chart Microfast® Quick Response Upright Sprinkler VK327 Maximum 175 PSI (12 bar) WWP Base Part Number1 SIN Thread Size Nominal K-Factor Overall Length Listings and Approvals3 NPT BSPT U.S.metric2 Inches mm cULus 21269 VK327 1/2”15 mm 4.2 57 2-3/16 56 A1, B2 Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) Approved Finishes 1 - Brass, Chrome, White Polyester5,6, and Black Polyester5,6 2 - ENT6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc. for us in the U.S. and Canada 5 Other colors are available on request with the same Listings and Approvals as the standard colors. 6 cULus Listed as corrosion resistant. DESIGN CRITERIA (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast® Quick Response Upright Sprinkler VK327 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet sys- tems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. • The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking Technical Data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Replaces Form F_061514 Rev 20.1 (Removed bushed part numbers) MIRAGE® QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK465 (K4.2)TECHNICAL DATA Form No. F_032107 Rev 01 April 2023 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Page 1 of 5 1. DESCRIPTIONViking Mirage® Quick Response Concealed Pendent Sprinkler VK465 is a thermo-sensitive glass-bulb spray sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired.The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile cover assembly that provides up to ½” (13 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The The “push-on” and “thread-on” designs of the concealed cover plate assemblies allow easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive environments and is listed and approved as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV Refer to the Approval Chart and Design Criteria for cULus Listing requirements that must be followed. 3. TECHNICAL DATA Specifications:Minimum Operating Pressure: 7 psi (0.5 bar). Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar).Thread size: 1/2” (15 mm) NPTNominal K-Factor: 4.2 U.S. (57 metric*) * Metric K-factor measurement is shown in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.Glass-bulb fluid temperature rated to -65 °F (-55 °C)Patents Pending Material Standards:Sprinkler Body: Brass UNS-C84400Deflector: Copper UNS-C19500Deflector Pins: Stainless Steel UNS-S30300Bulb: Glass, nominal 3 mm diameterPip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400Button: Brass UNS-C36000 Screws: 18-8 Stainless SteelBelleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE TapeYoke: Phosphor Bronze UNS-C51000Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials:Cover: Copper UNS-C11000Base: Brass UNS-C26000 or UNS-C26800Springs: Nickel AlloySolder: Eutectic Ordering Information: The sprinkler and cover plate must be ordered separately. Refer to Tables 1 and 2. 4. INSTALLATIONRefer to appropriate NFPA Installation Standards. 5. OPERATIONDuring fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCERefer to NFPA 25 for Inspection, Testing and Maintenance requirements. For Light Hazard Occupancies Only Replaces Form No. F_032107 Rev 21.1 (Adding venting statement (s)) MIRAGE® QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK465 (K4.2)TECHNICAL DATA Form No. F_032107 Rev 01 April 2023 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Page 2 of 5 7. AVAILABILITYViking Mirage® Concealed Pendent Sprinkler VK465 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEEFor details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: SPRINKLER ORDERING INFORMATION Instructions: (1) Select a Sprinkler Base Part Number (2) Add the suffix for the desired Finish (3) Add the suffix for the desired Sprinkler Temperature Rating (4) Order a cover plate (refer to Table 2) Example: 21274AE = 200 °F (93 °C) Temperature Rated Sprinkler with a standard Brass finish. SIN Sprinkler Base Part Number Size 1: Finishes 2: Temperature Ratings NPT Inch BSPT mm Description Suffix1 Sprinkler Temperature Classification Nominal Rating Bulb Color Max. Ambient Ceiling Temperature2 Suffix VK465 21274 1/2 15 Brass A Ordinary 155 °F (68 °C)Red 100 °F (38 °C)B ENT 3,4 JN Intermediate 175 °F (79 °C)Yellow 150 °F (65 °C)D Intermediate 200 °F (93 °C)Green 150 °F (65 °C)E Accessories Sprinkler Wrenches and tools (see Figure 1): A. Heavy Duty Part Number: 14047W/B5 (available since 2006) B. Head Cabinet Wrench Part Number: 140316 (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part Number: 144127 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 148677 (available since 2007) Sprinkler Cabinet:Holds up to 6 sprinklers: Part number 01731A (available since 1971). Footnotes 1. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. 2. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. cULus Listed as corrosion resistant. 4. The corrosion resistant and corrosion proofing coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. 5. Requires a ½” ratchet (not available from Viking). 6. Also optional for removal of the protective cap. Ideal for sprinkler cabinets. 7. The installer tool is for push-on style cover plates only. MIRAGE® QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK465 (K4.2)TECHNICAL DATA Form No. F_032107 Rev 01 April 2023 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Page 3 of 5 TABLE 2: COVER PLATE ORDERING INFORMATION Instructions: (1) Select a Cover Plate Base Part Number (2) Add the suffix for the desired Finish (3) Add the suffix for the required Cover Plate Nominal Rating. Example: 23190MC/W = 165 °F (74 °C) Temperature Rated, 2-3/4” (70 mm) diameter, Thread-On style Round Cover Plate with a Painted White finish. 1: Select a Cover Plate Base Part Number3 2: Select a FinishThread-On Style Push-On Style Base Part Number Size Inch (mm)Type Base Part Number Size Inch (mm)Type Description Suffix5 23190 2-3/4 (70)Round 23447 2-3/4 (70)Round Polished Chrome F 23174 3-5/16 (84)Round 23463 3-5/16 (84)Round Brushed Chrome F-/B 23179 3-5/16 (84)Square 23482 3-5/16 (84)Square Bright Brass B Antique Brass B-/A Brushed Brass B-/B Brushed Copper E-/B Painted White M-/W Painted Ivory M-/I Painted Black M-/B 3: Temperature Rating Matrix1,2 Cover Plate Nominal Rating (Required) Temperature Classification Sprinkler Nominal Rating Sprinkler Maximum Ambient Ceiling Temperature2 Suffix UL: 135 °F (57 °C)Ordinary 155 °F (68 °C)100 °F (38 °C)A 165 °F (74 °C)Intermediate 175 °F (79 °C)150 °F (65 °C)C 165 °F (74 °C)Intermediate 200 °F (93 °C)150 °F (65 °C)C Footnotes 1. The sprinkler temperature rating is stamped on the deflector. 2. Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 4. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. 5. Square cover plates 23179 and 23482 cULus Listing is for the 135 °F (57 °C) temperature rated cover plate only. Refer to the Approval Chart. Figure 1: Identification of Custom Paint for Concealed Covers All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 2: Square Cover Assembly 3-5/16” (84 mm)FACTORY APPLIE D CUSTO M P A I NT COLOR MIRAGE® QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK465 (K4.2)TECHNICAL DATA Form No. F_032107 Rev 01 April 2023 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Page 4 of 5 DESIGN CRITERIA (Also refer to the Approval Chart ) cULus Listing Requirements: Mirage® Quick Response Concealed Pendent Sprinkler VK465 is cULus Listed as a quick response sprinkler for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below: • Limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems, or hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. • Maximum spacing allowed is 15 ft. (4.6 m). • Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. • Minimum distance from walls is 4 in. (102 mm). • Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. • The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. • Venting is required. • Concealed sprinklers must NOT be installed in positive pressure plenums. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080416 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the lat- est edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, Assemblee Pleniere, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Approval Chart Mirage® Quick Response Concealed Pendent Sprinkler VK465 For Light Hazard Occupancies Only; Maximum 175 PSI (12 bar) WWP Sprinkler Base Part Number1 SIN NPT Thread Size Nominal K-Factor Overall Length (Sprinkler Body) Listings and Approvals3 (Refer also to Design Criteria on page 64d.) Inch mm U.S.metric2 Inches mm cULus4 FM NYC VdS LPCB 21274JN8 VK465 1/2”15 4.2 57 2-3/16”56 AW1, BX1 --See Footnote 5.-------- 21274A VK465 1/2”15 4.2 57 2-3/16”56 AW1, BX1 --See Footnote 5.-------- Sprinkler Temperature Ratings A - 155 °F (68 °C) B - 175 °F (79 °C) and 200 °F (93 °C) Cover Plate Assembly Temp. Ratings6 W - 135 °F (57 °C) cover, 231901, 234471 231741, 234631 (large diameter), or 231791, 23482 1 (square cover plate) X - 165 °F (74 °C) cover 231901, 234471, or 231741, 234631 (large diameter) Finishes of the Cover Plate Assembly7 1 - Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Footnotes 1. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2. Metric K-factor measurement is shown in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4. Listed by Underwriter’s Laboratories for use in the U.S. and Canada. 5. Meets New York City requirements, effective July 1, 2008. 6. The 135 °F (57 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label. 7. Standard painted finishes consist of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. 8. cULus Listed as corrosion resistant. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. MIRAGE® QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK465 (K4.2)TECHNICAL DATA Form No. F_032107 Rev 01 April 2023 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Page 5 of 5 Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins Sprinkler Wrench Part No. 14047W/B** ** A 1/2” ratchet is required (Not available from Viking) 2-1/4” (57 mm) diameter opening required in the ceiling. Step 2: Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Figure 3: Sprinkler Installation and Proper Wrench Usage NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Sprinkler wrench flat Sprinkler frame arms Figure 4: Sprinkler Dimensions and Cover Installation 1/2” (15 mm) NPT 2-3/16”(55 mm)2-3/4” (70 mm)Maximum 2-1/4” (57 mm)Minimum 2-3/4” (70 mm) or 3-5/16” (84 mm)NOTE: Upon sprinkler activation, the deflector descends to approximately 13/16” (21 mm) below the sprinkler body. Replaces Form No. F_032107 Rev 21.1 (Adding venting statement (s)) MICROFAST® QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) TECHNICAL DATA Page 1 of 6 Form No. F_060914 19.11.21 Rev 19.2 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION The Viking Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in Approval Charts. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 China Approval: Approved according to China GB Standard Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Nominal K-Factor: 5.6 U.S. (80.6 metric*) * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Overall Length: 2-3/4” (68 mm) Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring - Exposed, Screw and Pip cap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 by first adding the appropriate suffix for the sprin- kler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F / 57 °C = A, 155 °F / 68 °C = B, 175 °F / 79 °C = D, 200 °F / 93 °C = E, and 286 °F / 141 °C = G For example, sprinkler 12997 with a Brass finish and a 155 °F / 68 °C temperature rating = Part No. 12997AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: A. Standard Wrench: Part No. 21475M/B (available since 2017). B. Wrench for recessed and/or wax coated sprinklers: Part No. 13655W/B** (available since 2006) **A ½” ratchet is required (not available from Viking). Replaces form F_060914 Rev. 19.1 (Revised China approval.) MICROFAST® QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) TECHNICAL DATA Page 2 of 6 Form No. F_060914 19.11.21 Rev 19.2 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive fusible link disengages, the pip cap and spring are released, and the waterway is opened. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 is available through a network of domestic and interna- tional distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench 21475M/B Wrench Flat MICROFAST® QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) TECHNICAL DATA Page 3 of 6 Form No. F_060914 19.11.21 Rev 19.2 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Figure 2: Wrench 13655W/B for Recessed Sprinklers Step 1: Carefully slide the wrench sideways around the deflector, ensuring en- gagement with the sprinkler wrench flats. Sprinkler wrench 13655W/B** must be used for installing wax coated sprinklers. ** A 1/2” ratchet is required (not available from Viking)Step 2: Carefully press the wrench onto the sprinkler wrench flats. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary 135 °F (57 °C)100 °F (38 °C)Orange Ordinary 155 °F (68 °C)100 °F (38 °C)Red Intermediate 175 °F (79 °C)150 °F (65 °C)Yellow Intermediate 200 °F (93 °C)150 °F (65 °C)Green High 286 °F (141 °C)225 °F (107 °C)Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and ENT Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. For ENT coated sprinklers, the waterway is coated. Note that the spring is exposed on sprinklers with Polyester, and ENT coatings. MICROFAST® QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) TECHNICAL DATA Page 4 of 6 Form No. F_060914 19.11.21 Rev 19.2 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA - UL (Also refer to Approval Chart 1.) cULus Listing Requirements: Quick Response Horizontal Sprinkler VK305 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies. • Locate with the deflector 4” to 12“ (102 mm to 305 mm) below the ceiling. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. • Minimum spacing allowed is 6 ft. (1.8 m). • Align the top of the deflector parallel with the ceiling. • Locate no less than 4” (102 mm) from end walls. • Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. • The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Approval Chart 1 (UL) Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 For Light or Ordinary Hazard Occupancies Maximum 175 PSI (12 Bar) WWP Deflector must be located 4” to 12” (102 mm to 305 mm) below the ceiling. Sprinkler Base Part Number1 SIN Thread Size Nominal K-Factor Overall Length Listings and Approvals3 (Refer also to UL Design Criteria.) NPT BSPT U.S.metric2 Inches mm cULus4 China Approval 12997 VK305 1/2”15 mm 5.6 80.6 2-11/16 68 A1W, B1X, C2W, D2Z -- 197827 VK305 1/2”--5.6 80.6 2-11/16 68 E3 E3 NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 12121 VK305 1/2”15 mm 5.6 80.6 2-11/16 68 A1W, B1X, C2W, D2Z -- Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141 °C) B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141 °C) D - 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) E - 155 °F (68 °C) Approved Finishes 1 - Brass, Chrome, White Poly-ester5,6, and Black Polyester5,6 2 - ENT5 3 - Chrome Approved Escutcheons W - Installed with standard surface-mounted escutcheons X - Installed with standard surface-mounted escutch- eons or recessed with the Viking Micromatic® Model E-1, E-2, or G-1 Recessed Escutcheon Z - Installed with standard surface-mounted escutch- eons or recessed with the Viking Micromatic Model E-1 Footnotes 1 Base part number shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. 7 Approved according to China GB Standard. MICROFAST® QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) TECHNICAL DATA Page 5 of 6 Form No. F_060914 19.11.21 Rev 19.2 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: Horizontal Sidewall Sprinkler VK305 is FM Approved as a quick response Non-Storage sidewall sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Approval Chart 1 (FM) Microfast® Quick Response Sidewall Sprinklers Maximum 175 PSI WWP Sprinkler Base Part Number1 SIN Thread Size Nominal K-Factor Overall Length FM Approvals3,4 (Refer also to Design Criteria below.)NPT BSPT U.S.metric2 Inches mm 12997 VK305 1/2”15 mm 5.6 80.6 2-11/16 68 A1Y, B1X NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 12121 VK305 1/2”15 mm 5.6 80.6 2-11/16 68 A1W, B1X, C2W, D2Z -- Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141 °C) B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) Approved Finishes 1 - Brass Approved Escutcheons X - Installed with standard surface-mounted escutch- eons or recessed with the Viking Micromatic® Model E-1, E-2, E-3, or G-1 Recessed Escutcheon Y - Installed with standard surface-mounted escutch- eons Footnotes 1 Base part number shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Other approvals may be in process. 4 Viking vertical sidewall sprinklers may be installed pendent or upright. 5 Approved according to China GB Standard. MICROFAST® QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) TECHNICAL DATA Page 6 of 6 Form No. F_060914 19.11.21 Rev 19.2 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Figure 4: Sidewall Sprinkler VK305 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Figure 3: Sidewall Sprinkler Dimensions with a Standard Escutcheon 2-3/4” (68 mm)2-7/16” (62 mm) Installed with a Standard 1/8” Surface-Mounted Escutcheon Wall Opening Size: 2-5/16” (58.7 mm) minimum 2-1/2” (63.5 mm) maximum 1-5/8” (41 mm) Installed with the Threaded Model E-2 Recessed Escutcheon Wall Opening Size: 2-5/16” (58.7 mm) minimum 2-1/2” (63.5 mm) maximum 2-1/8” (54 mm) 2-1/4” (57 mm) Maximum Minimum 2-1/8” (54 mm) 2-5/8” (67 mm) Maximum 1-3/4” (45 mm) Minimum Installed with the Micromatic Model E-1 Recessed Escutcheon Replaces form F_060914 Rev. 19.1 (Revised China approval.) QUICK RESPONSE DRY PENDENT SPRINKLERSTECHNICAL DATA Form No. F_031793 19.10.14 Rev 19.2 Page 1 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION Viking Quick Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry sys- tems and preaction systems where it is necessary to prevent water or condensation from entering the drop nipple before sprinkler operation. They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Quick Response Dry Pendent Sprinklers are available in various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global has no approval classification for Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2013 and 2015 NYC Approved: MEA 89-92-E Volume 15 Refer to Approval Chart 1 and Design Criteria on page 105d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 105e for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1” NPT or 25 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric*) for all listed and approved lengths. * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Covered by the following U.S. Patents: 8,636,075 and 10,220,231 Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Pip Cap: Brass UNS-C31400 or UNS-C31600 Pip Cap Adapter: Brass UNS-C36000 Orifice: Copper UNS-C22000 or UNS-C11000 Tube: ERW Hydraulic Steel Tube Support (Internal): Stainless Steel UNS-S30400 Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Barrel End and Threads: QM Brass Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 ENT Coated Adjustable and Recessed Escutcheons: Stainless Steel UNS-S30400 Ordering Information: (Also refer to the current Viking price list.) Replaces Form F_031793 Rev. 19.1 (Added ENT; updated FM language.) QUICK RESPONSE DRY PENDENT SPRINKLERSTECHNICAL DATA Form No. F_031793 19.10.14 Rev 19.2 Page 2 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Order Quick Response Dry Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish, the appropriate suffix for the temperature rating, and then the suffix for the length (“A” dimension) to sprinkler base part number. Order in a specific length noted as the “A” dimension. The “A” dimension is the distance from the face of the fitting (tee) to the desired finished surface of the ceiling. These sprinklers are listed and approved in lengths from 1-1/2” to 45-1/2” (38.1 mm to 1,156 mm) for the adjustable standard style, 3” to 47” (76.2 mm to 1,194 mm) for the plain barrel style, and 3-1/4” to 47-1/2” (82.5 mm to 1,207 mm) for the adjustable recessed style. Lengths exceeding the standard lengths are available, with no approvals, on a “made-to-order” basis: Recessed Dry Pendent up to 65-1/2” (1,664 mm). Adjustable Standard Dry Pendent up to 63-1/2” (1,613 mm). Plain Barrel Dry Pendent up to 65” (1,651 mm). Contact the manufacturer for more information. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G For example, sprinkler VK176 with a Chrome finish and a 155 °F (68 °C) temperature rating, and “A” length of 10” = Part No. 08383UFB10. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the “Sprinkler Accessories” section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 07297W/B (available since 1991) B. Wrench for recessed sprinklers: Part No. 07565W/B** (available since 1991) **A ½” ratchet is required (not available from Viking). Sprinkler Guard: Chrome, with no listings or approvals, for installation on dry pendent sprinklers made after May 1994 only (Part No. 08954). Replacement Escutcheons: A. Adjustable Standard Dry Escutcheon: Base Part No. 07741 B. Recessed Dry Escutcheon Cup: Base Part No. 05459A 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the internal parts to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS & MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Quick Response Dry Pendent Sprink- ler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench 07297W/B Figure 2: Wrench 07565W/B for Adjustable Recessed Dry Pendent Sprinklers QUICK RESPONSE DRY PENDENT SPRINKLERSTECHNICAL DATA Form No. F_031793 19.10.14 Rev 19.2 Page 3 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary 155 °F (68 °C)100 °F (38 °C)Red Intermediate 175 °F (79 °C)150 °F (65 °C)Yellow Intermediate 200 °F (93 °C)150 °F (65 °C)Green High 286 °F (141 °C)225 °F (107 °C)Blue Sprinkler Finishes: Brass, Chrome, White Polyester, and ENT Corrosion-Resistant Coating3,4: White Polyester and ENT in all temperature ratings Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant Polyester and ENT coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Note: These coatings are NOT cor- rosion proof. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environ- ment. Polyester and ENT coatings are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. 4 When installed in some corrosive environments, the Polyester finish may change color. This natural discoloration over time is not in itself an indication of corrosion and should not be treated as such. All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. Figure 3: Adjustable Standard Dry Pendent Sprinkler QUICK RESPONSE DRY PENDENT SPRINKLERSTECHNICAL DATA Form No. F_031793 19.10.14 Rev 19.2 Page 4 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 1 (UL) Quick Response Dry Pendent Sprinklers Maximum 175 PSI (12 bar) WWP Sprinkler Base Part No.1 SIN Style Thread Size Nominal K-Factor2 Order Length Increment Listings and Approvals4 (Refer also to Design Criteria below.) NPT BSP U.S.metric3 Inches mm cULus5 NYC6 VdS LPCB 08383U VK176 Adjustable Standard 1”--5.6 80.6 1/2”12.7 A1, A5 A1 -------- 16457U --25 mm --80.6 1/2”12.7 A1, A5 ---------- 08385U VK180 Adjustable Recessed 1”--5.6 80.6 1/4”6.35 B2, B6 B2 -------- 16453U --25 mm --80.6 1/4”6.35 B2, B6 ---------- 08387U VK172 Plain Barrel 1”--5.6 80.6 1/2”12.7 A3 A4 -------- 16455U --25 mm --80.6 1/2”12.7 A3 ---------- Approved Temperature Ratings A - 155 °F (68 °C), 175 °F (79°C), 200 °F (93 °C), and 286 °F (141 °C) B - 155 °F (68 °C), 175 °F (79°C), and 200 °F (93 °C) Approved Finishes and “A” Dimensions 1 - Chrome or White Polyester7 sprinkler with a Chrome or White Polyester Sleeve and Escutcheon with “A” dimensions 1-1/2” to 45-1/2” (38.1 mm to 1,156 mm) 2 - Chrome or White Polyester7 with “A” dimensions 3-1/4” to 47-1/2” (82.5 mm to 1,207 mm) 3 - Chrome, Brass, White Polyester7, or ENT 7 with “A” dimensions 3” to 47” (76.2 mm to 1,194 mm) 4 - Chrome or Brass with “A” dimensions 3” to 47” (76.2 mm to 1,194 mm) 5 - ENT7 sprinkler with an ENT7 Sleeve and Escutcheon with “A” dimensions 1-1/2” to 45-1/2” (38.1 mm to 1,156 mm) 6 - ENT7 with “A” dimensions 3-1/4” to 47-1/2” (82.5 mm to 1,207 mm) Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths (“A” Dimensions indicated above). 3 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 4 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 5 Listed by Underwriter’s Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 15. 7 cULus Listed as corrosion resistant. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-Bl tees. When selecting other CPVC fittings, contact Viking Technical Services. cULus Listing Requirements: Standard Dry Pendent Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies. • The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. QUICK RESPONSE DRY PENDENT SPRINKLERSTECHNICAL DATA Form No. F_031793 19.10.14 Rev 19.2 Page 5 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.comApproval Chart 2 (FM) Quick Response Dry Pendent Sprinklers Maximum 175 PSI (12 bar) WWP Sprinkler Base Part No.1 SIN Style Thread Size Nominal K-Factor2 Order Length Increment FM Approvals4 (Refer also to Design Criteria below.)NPT BSP U.S.metric3 Inches mm 08383U VK176 Adjustable Standard 1”--5.6 80.6 1/2”12.7 A1 16457U --25 mm --80.6 1/2”12.7 A1 08385U VK180 Adjustable Recessed 1”--5.6 80.6 1/4”6.35 B2 16453U --25 mm --80.6 1/4”6.35 B2 08387U VK172 Plain Barrel 1”--5.6 80.6 1/2”12.7 A3 16455U --25 mm --80.6 1/2”12.7 A3 Approved Temperature Ratings A - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141 °C) B - 155 °F (68 °C), 175 °F (79°C), and 200 °F (93 °C) Approved Finishes and “A” Dimensions 1 - Brass, Chrome, White Polyester, or ENT5 sprinkler with a Brass, Chrome, White Polyester, or ENT5 Sleeve and Escutcheon with “A” dimensions 1-1/2” to 45-1/2” (38.1 mm to 1,156 mm) 2 - Brass, Chrome, White Polyester, or ENT5 with “A” dimensions 3-1/4” to 47-1/2” (82.5 mm to 1,207 mm) 3 - Brass, Chrome, White Polyester, or ENT5 with “A” dimensions 3” to 47” (76.2 mm to 1,194 mm) Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths (“A” Dimensions indicated above). 3 Metric K-Factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 4 This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any ad-ditional approvals. 5 FM approved as corrosion resistant. Figure 4: Adjustable Recessed Dry Pendent Sprinkler Figure 5: Plain Barrel Dry Pendent Sprinkler DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-Bl tees. When selecting other CPVC fittings, contact Viking Technical Services. FM Approval Requirements: The Dry Pendent Sprinklers in the Approval Chart above are FM Approved as quick response Non-storage standard spray sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (includ-ing 2-0) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. QUICK RESPONSE DRY PENDENT SPRINKLERSTECHNICAL DATA Form No. F_031793 19.10.14 Rev 19.2 Page 6 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Figure 6: Dry Pendent Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry Pendent Sprinkler is Shown) Figure 7: Dry Sprinkler Seal (Adjustable Standard Dry Pendent Sprinkler is Shown) Replaces Form F_031793 Rev. 19.1 (Added ENT; updated FM language.) PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SS-01.18 page 1 SS-SUB-92-v01 20220505 Anvil® Beam Clamps Universal C-type Clamp (Standard Throat) Fig. 92 (Formerly Afcon Fig. 100) Dimensions (In) - Load (Lbs) - Torque (In-Lbs) - Weight (Lbs) Rod SizeA Set Screw Size Torque Value Max Loads Weight C D E F G HTopBottom In.In.In.-Lbs.Lbs.Lbs.Lbs.In.In.In.In.In.In. 3/8 3/8 60 500 250 0.34 1 5/16 1 9/16 9/16 13/16 3/8 1/2 1/2 1/2 125 950 760 0.63 1 3/8 1 13/16 1/2 1 1/16 7/16 23/32 Material Specifications Size Range 3/8" and 1/2" Material Ductile iron, hardened steel cup point set screw and locknut. Finish Plain Zinc Plated (Hot-Dip Galvanized optional) Service Recommended for use under roof installations with bar joist type construction, or for attachment to the top or bottom flange of structural shapes where the vertical hanger rod is required to be offset from the edge of the flange and where the thickness of joist or flange does not exceed 3/4". Approvals Complies with Federal Specification A-A-1192A (Type 19 & 23), WW-H-171-E (Type 23), ANSI/MSS SP-69 and MSS SP-58 (Type 19 & 23). UL, ULC Listed and FM Approved. How to size Size of clamp is determined by size of rod to be used. Installation Follow recommended set screw torque values per MSS-SP-69. Features • They may be attached to horizontal flanges of structural members in either the top beam or bottom beam positions. • Secured in place by a cup-pointed Set Screw tightened against the flange. A Jam Nut is provided for tightening the Set Screw against the Body Casting. • Thru tapping of the body casting permits extended adjustment of the threaded rod. • Can be used with Fig 89X retaining clip for seismic applications. Ordering Specify rod size, figure number, name of clamp and finish. Available with oversized tapped rod hole for Hot Dip Galvanized finish. Note:  Maximum temperature of 450° F Threaded Accessories 116688 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. FFiigguurree BB33220055 TThhrreeaaddeedd RRoodd ((rriigghhtt--hhaanndd tthhrreeaaddss -- bbootthh eennddss)) ((AAvvaaiillaabbllee wwiitthh rriigghhtt && lleefftt--hhaanndd tthhrreeaaddss aass BB33220055LL--ssiizzee)) MMaatteerriiaall::Steel SSttaannddaarrdd FFiinniisshh:: Plain or Electro-Plated SSeerrvviiccee:: Designed for use in pipe hanger assemblies. OOrrddeerriinngg:: Specify part number, length and finish. (B3205L for left hand threads on one end) MMaatteerriiaall::Steel SSttaannddaarrdd FFiinniisshh:: Plain or Electro-Plated SSeerrvviiccee:: Designed for use in pipe hanger assemblies. SSttaannddaarrdd LLeennggtthhss ‘‘LL’’:: 36” (91.4cm), 72” (182.9cm), 120” (304.8cm), 144” (365.7cm) OOrrddeerriinngg:: Specify part number, length and finish. ''AA'' TThhrreeaadd SSiizzee ''TTLL'' ''TTLL'' SSppeecciiffyy ''LL'' SSttaannddaarrdd DDeessiiggnn LLooaadd TThhrreeaadd SSiizzee TThhrreeaadd LLeennggtthh 665500°°FF ((334433°°CC))775500°°FF ((339999°°CC)) PPaarrtt NNoo..''AA''''TTLL''LLbbss..kkNN LLbbss..kkNN BB33220055--33//88 xx ''LL''33//88""--1166 2211//22""((6633..55))773300 ((33..2255))557722 ((22..5544)) BB33220055--11//22 xx ''LL''11//22""--1133 2211//22""((6633..55))11335500 ((66..0000))11005577 ((44..7700)) BB33220055--55//88 xx ''LL''55//88""--1111 2211//22""((6633..55))22116600 ((99..6611))11669922 ((77..5522)) BB33220055--33//44 xx ''LL''33//44""--1100 33""((7766..22))33223300 ((1144..3377))22553300 ((1111..2255)) BB33220055--77//88 xx ''LL''77//88""--99 3311//22""((8888..99))44448800 ((1199..9933))33550088 ((1155..6600)) BB33220055--11 xx ''LL''11""--88 44""((110011..66))55990000 ((2266..2244))44662200 ((2200..5555)) BB33220055--1111//88 xx ''LL''1111//88""--77 4411//22""((111144..33))77445500 ((3333..1144))55883300 ((2255..9933)) BB33220055--1111//44 xx ''LL''1111//44""--77 55""((112277..00))99550000 ((4422..2255))77444400 ((3333..0099)) BB33220055--1111//22 xx ''LL''1111//22""--66 66""((115522..44))1133880000 ((6611..3388))1100880077 ((4488..0077)) BB33220055--1133//44 xx ''LL''1133//44""--55 77""((117777..88))1188660000 ((8822..7733))1144556666 ((6644..7799)) BB33220055--22 xx ''LL''22""--4411//22 88""((220033..22))2244660000 ((110099..4422))1199662255 ((8877..2299)) BB33220055--2211//44 xx ''LL''2211//44""--4411//22 99""((222288..66))3322330000 ((114433..6677))2255229955 ((111122..5511)) BB33220055--2211//22 xx ''LL''2211//22""--44 1100""((225544..00))3399880000 ((117777..0033))3311116699 ((113388..6644)) BB33220055--2233//44 xx ''LL''2233//44""--44 1111""((227799..44))4499440000 ((221199..7733))3388668877 ((117722..0088)) BB33220055--33 xx ''LL''33""--44 1122""((330044..88))6600110000 ((226677..3322))4477006666 ((220099..3355)) BB33220055--3311//44 xx ''LL''3311//44""--88UUNN 1133""((333300..22))7711990000 ((331199..8811))5566330077 ((225500..4455)) BB33220055--3311//22 xx ''LL''3311//22""--88UUNN 1144""((335555..66))8844770000 ((337766..7744))6666333311 ((229955..0044)) BB33220055--3333//44 xx ''LL''3333//44""--88UUNN 1155""((338811..00))9988550000 ((443388..1133))7777113399 ((334433..1111))Threaded AccessoriesPPaarrtt NNoo..TThhrreeaaddss RReeccoommmmeennddeedd LLooaadd WWtt..//CC FFtt.. && SSiizzee PPeerr IInncchh LLbbss..kkNN LLbbss..kkgg AATTRR 11//44”” xx ‘‘LL’’2200 224400 ((11..0077))1122 ((55..4444)) AATTRR 55//1166”” xx ‘‘LL’’1188 440000 ((11..7788))1199 ((88..6622)) AATTRR 33//88”” xx ‘‘LL’’1166 773300 ((33..2244))2299 ((1133..1155)) AATTRR 11//22”” xx ‘‘LL’’1133 11335500 ((66..0000))5533 ((2244..0044)) AATTRR 55//88”” xx ‘‘LL’’1111 22116600 ((99..6600))8899 ((4400..3377)) AATTRR 33//44”” xx ‘‘LL’’1100 33223300 ((1144..3377))112233 ((5555..7799)) AATTRR 77//88”” xx ‘‘LL’’99 44448800 ((1199..9933))117700 ((7777..1111)) AATTRR 11”” xx ‘‘LL’’88 55990000 ((2266..2244))222255 ((110022..0066)) BLine_160-175 7/24/06 5:17 PM Page 168 PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: Pipe Hangers & Supports SS-01.18 page 1 SS-SUB-69-v01 20220325 Adjustable Swivel Ring Fig. 69 Size Range: ¾" through 8" Material: Carbon steel Finish: Strap is Pre-Galvanized Zinc Material. Nut is Zinc Plated. Service: Recommended for suspension of non-insulated stationary pipe line. Maximum Temperature: 450° F Approvals: Complies with Federal Specification A-A-1192A (Type 10), WW-H-171-E (Type 10), and ANSI/MSS SP-58 (Type 10). UL Listed and FM Approved (Sizes ¼" - 8"). Features: • ¾" - 2" sizes designed for use with steel and CPVC piping and manufactured with FBC System Compatible oil. • Threads are countersunk so that they cannot become burred or damaged. • Knurled swivel nut provides vertical adjustment after piping is in place. • Captured swivel nut in the 1⁄2" through 6" sizes. The capture is permanent in the bottom portion of the band, allowing the hanger to be opened during installation if desired, but not allowing the nut to fall completely out. Ordering: Specify size, figure number and name. Non-captured nut also available upon request. Fig. 69: Dimensions (in) • Loads (lbs) • Weight (lbs) Pipe Size Max Load Weight Rod Size A B C F G Width 1⁄2 300 0.10 3⁄8 27⁄8 2 19⁄16 5⁄8 3⁄4 0.10 23⁄4 17⁄8 15⁄16 1 0.10 29⁄16 111⁄16 1 11⁄4 0.10 25⁄8 13⁄4 7⁄811⁄2 0.10 23⁄4 17⁄8 2 0.11 31⁄4 23⁄8 11⁄8 21⁄2 525 0.20 4 23⁄4 15⁄16 3⁄4 3 0.20 313⁄16 215⁄16 13⁄16 4 650 0.30 411⁄16 313⁄16 19⁄165 1,000 0.54 1⁄2 55⁄16 43⁄8 6 0.65 611⁄16 59⁄16 21⁄4 8 1.00 89⁄16 79⁄16 31⁄4 21/2" through 8" pipe1/2" through 1" pipe 11/4" through 2" pipe B C F CL G A B C CL G A F A BCF CL G 1/2" through 2" SizeRounded Edge Design 21/2" through 8" Size