Loading...
309 PLAZA RES23-0026 Goldwasser House ARCH DWGSREAR PERSPECTIVEFRONT ELEVATIONRIGHT ELEVATIONPROPOSED RESIDENCE FORAREA132065 (904) 545-3456wasserSCALE 1/4" = 1'-0"SCALE 1/4" = 1'-0"WINDOWSWINDOWS TO BE VINYL SINGLE HUNG CWINSUL GLASS AND MUNTINS AS SHOWNSOFFIT & FASCIASOFFIT & FASCIA TO BE VINYL VENTEDSOFFIT WITH VINYL COATED ALUMINUMFASCIASteve & Becky GoldwasserBy Toni Gindlesperger at 10:47 am, Feb 16, 2023By Mike Jones at 11:12 am, Sep 27, 2023 WINDOW6.512VINYL SINGLE HUNG CW MIN. 1/2" INSULGLASS AND HALF SCREENSMUNTINS AS SHOWN ON ELEVATIONSROOF30 YR ARCHITECTURAL SHINGLES CWDOUBLE LAYER 30# SYNTHETIC DRY IN1/2" OSB SHEATHING CW CLIPSENGINEERED ROOF TRUSSES @ 24" OCR19 MIN. FOAM INSULATIONLEFT ELEVATIONRIGHT ELEVATION2065 (904) 545-34562asserSCALE 1/4" = 1'-0"SCALE 1/4" = 1'-0"WINDOWSWINDOWS TO BE VINYL SINGLE HUNG CWINSUL GLASS AND MUNTINS AS SHOWNSOFFIT & FASCIASOFFIT & FASCIA TO BE VINYL SOLID SOFFITWITH VINYL COATED ALUMINUM FASCIA12 DNDNDN2DB6418162DB641816W3042W3042608020803060SH3060SH60803060SH3060SH100804020FX28804020FX2020FX2020FX4050SH2460SH2460SH6014FX608020803050PT3050PT3650LS3650LS2056FX10080288UP2'-6"4'-8"2'-8"1'-0"2'-5"4'-6"2'-6"3'-11"2'-8"2'-0"18'-4"3'-4"3'-4"7'-10"7'-10"7'-4"7'-4"3'-7"4'-6"4'-3"3'-8"7'-11"4'-6"3'-7"7'-4"7'-4"14'-8"12'-4"19'-8"14'-8"61'-4"2'-4"1'-11"4'-6"1'-11"2'-4"13'-0"32'-8"15'-8"61'-4"2'-9"10'-2"2'-5"15'-4"3'-7"6'-8"5'-4"9'-5"6'-7"20'-4"2'-4"69'-7"4'-0"3'-8"2'-4"21'-4"2'-9 1/2"2'-9 1/2"2'-4"21'-4"5'-7"17'-9"9'-10"12'-9"69'-7"2'-4"1'-8"2'-0"12'-9"4'-11"4'-2"3'-414'-0"11'-2"11'-0"11'-2"14'-0"11'-0"11'-0"10'-8"14'-4 1/4"12'-4"7'-11"4'-5 1/2"3'-4"4'-7"14'-4 1/4"112'-4"15'-4"5'-4"3'-11"1'-11"4'-6"3'-4"5'-8"3'-4"256 sq ft72 294 sq ft302 sq ft168 sq ft153 sq ft172 sq ft101 sq ft19 sq ft28 sq ftGarage 2Garage 1Master BdrmPorchOfficeMLauEntryWineCellarWCShowerDOOR SCHEDULEQTY FLOOR SIZE WIDTH HEIGHT THICKNESS DESCRIPTION2 1 10080 120 " 96 " 1 3/4" GARAGE-EASTON1 1 12080 L/R EX 144 " 96 " 1 3/4" EXT. QUAD SLIDER-GLASS PANEL2 1 2080 R 24 " 96 " 1 3/8" POCKET-DOOR P041 1 2080 R IN 24 " 96 " 1 3/8" HINGED-DOOR P041 1 2080 L IN 24 " 96 " 1 3/8" HINGED-DOOR P042 1 2480 R IN 28 " 96 " 1 3/8" HINGED-DOOR P041 1 2668 R 30 " 80 " 1/2" SHOWER-GLASS SLAB1 2 2668 L 30 " 80 " 1/2" SHOWER-GLASS SLAB1 2 2668 R 30 " 80 " 1/2" SHOWER-GLASS SLAB1 1 2680 L 30 " 96 " 1 3/8" POCKET-DOOR P041 1 2680 R IN 30 " 96 " 1 3/8" HINGED-DOOR P043 2 2680 R 30 " 96 " 1 3/8" POCKET-DOOR P041 2 2680 L EX 30 " 96 " 1 3/4" EXT. HINGED-GLASS PANEL1 2 2680 L IN 30 " 96 " 1 3/8" HINGED-DOOR P041 2 2680 L 30 " 96 " 1 3/8" POCKET-DOOR P041 2 2680 R EX 30 " 96 " 1 3/4" EXT. HINGED-GLASS PANEL1 2 2680 R IN 30 " 96 " 1 3/8" HINGED-DOOR P041 1 2880 R 32 " 96 " 1 3/8" BARN-PRAIRIE DOOR2 1 2880 L EX 32 " 96 " 1 3/8" EXT. HINGED-DOOR P041 1 2880 L EX 32 " 96 " 1 3/4" EXT. HINGED-GLASS PANEL1 1 2880 L IN 32 " 96 " 1 3/8" HINGED-DOOR P041 1 2880 L 32 " 96 " 1 3/8" POCKET-DOOR P041 1 2880 R EX 32 " 96 " 1 3/8" EXT. HINGED-DOOR P041 1 2880 R IN 32 " 96 " 1 3/8" HINGED-DOOR F042 1 2880 R IN 32 " 96 " 1 3/8" HINGED-DOOR P041 2 2880 L IN 32 " 96 " 1 3/8" HINGED-DOOR P042 2 3080 R IN 36 " 96 " 1 3/8" HINGED-DOOR P041 2 6080 R IN 72 " 96 " 1 3/8" SLIDER-DOOR P041 1 6080 L/R EX 72 " 96 " 1 3/4" EXT. DOUBLE HINGED-DOOR L041 1 6080 L/R EX 72 " 96 " 1 3/4" EXT. DOUBLE HINGED-GLASS PANEL1 1 6080 L/R IN 72 " 96 " 1 3/8" DOUBLE HINGED-DOOR F041 2 6080 L/R IN 72 " 96 " 1 3/8" DOUBLE HINGED-DOOR F041 1 9080 L EX 108 " 96 " 1 3/4" EXT. 0+3-PANEL SLIDER-GLASS PANEL1 2 6080 L EX 72 " 96 " 1 3/4" EXT. SLIDER-GLASS PANEL1 2 3080 L IN 36 " 96 " 1 3/8" HINGED-DOOR P041 2 2880 R IN 32 " 96 " 1 3/8" HINGED-DOOR P04WINDOW SCHEDULEQTY FLOOR SIZE WIDTH HEIGHT DESCRIPTION2 1 2020FX 24 " 24 " FIXED GLASS2 2 2020FX 24 " 24 " FIXED GLASS2 2 2030FX 24 " 36 " FIXED GLASS1 1 2056FX 24 " 66 " FIXED GLASS1 2 6070FX 72 " 84 " FIXED GLASS1 3 2440SH 28 " 48 " SINGLE HUNG2 2 3060FX 36 " 72 " FIXED GLASS2 1 2460SH 28 " 72 " SINGLE HUNG4 1 3060SH 36 " 72 " SINGLE HUNG6 2 3060SH 36 " 72 " SINGLE HUNG2 1 4020FX 48 " 24 " FIXED GLASS1 1 4050SH 48 " 60 " SINGLE HUNG2 1 3650LS 42 " 60 " LEFT SLIDING1 1 5056LS 60 " 66 " LEFT SLIDING1 1 6014FX 72 " 16 " FIXED GLASSSILL @ 24" AFFSILL @ 24" AFFSILL @ 36" AFFTEMP GLASSSILL @ 84" AFFTEMP GLASSSILL @ 84" AFFSILL @ 72" AFFSILL @ 42" AFFSILL @ 48" AFFTEMP GLASSSILL @ 48" AFFTEMP GLASSSILL @ 24" AFFSILL @ 24" AFFBLACKOUT WINDOWS10' PLATE6.5/12 VAULTED CEILINGTANKLESSGASWATERHEATERTANKLESSGASWATERHEATERWC66" FREESTANDING TUB8" SHELF @ 36"AFF12" SEAT @ 16" AFFSHAMPOO NICHEWASHERDRYE1010' CEILINGOVERHEAD DOOR10' CEILINGOVERHEAD DOOR10' CEILINGFULL LITE GLASSWOOD / METAL RAILINGOPENABOVE11' CEILINGSILL @48" AFFAC#1AC#2Open DeckPT FRAMED STEPS TO GRADEPT FRAMED STEPS TO GRADEPT FRAMED STEPS TO GRADELiving Area2334 sq ftMAIN FLOOR PLANSCALE 1/4" = 1'-0"SHEETREVAPPROVEDSCALEDATEDRAWN BYSHEET TITLEPLANPROPOSED RESIDENCE FORRBM#401 - 1031 Blanding Blvd. O.P., 32065 (904) 545-3456Goldwasser3MAIN FLOOR PLANSteve & Becky Goldwasser12/14/22Duval Construction DNB2721B2721B2721B2721B2721B2721U242490U242490U24249026803060SH3060SH2020FX26682020FX3060SH3060SH26803060FX3060FX6070FX3060SH3060SH608030802030FX2030FX6080 SGD308028802668268026806080288026803080288028802680268026808'-10 1/2"5'-2"5'-2"8'-10 1/2"6'-9 1/4"8'-4 3/4"18'-1"4'-9"5'-2"4'-9"3'-7"4'-6"7'-11"7'-11"4'-6"3'-7"4'-9"5'-2"4'-9"14'-8"32'-0"14'-8"61'-4"20'-2"18'-0"23'-2"36'-5"18'-1"3'-6"11'-0"3'-6"18'-1"9'-4"8'-9"10'-4 1/4"4'-0"8'-0"4'-4"15'-11"4'-4 1/2"4'-0"10'-4 1/4"3'-6"3'-6"3'-4 1/4"4'-0"4'-0"3'-4 1/4"3'-6"3'-6"12'-5"4'-7"5'-8"10'-1"10'-4"2'-4"4'-4"15'-9"61'-4"3'-8"3'-8"6'-7"6'-8"7'-4"15'-10"36'-5"1'-8"2'-0"3'-8"3'-6"3'-6"7'-0 1/2"6'-9 1/4"26'-5 3/4"7'-0 1/2"3'-6"3'-6"3'-8"3'-8"15'-10"7'-4"6'-8"6'-7"36'-5"2'-0"1'-8"3'-8"5'-8"1'-8"5'-8"1'-8"14'-0"11'-2"11'-0"11'-2"14'-0"4'-0"20'-0"8'-7 1/2"326 sq ft402 sq ft230 sq ft23 sq ft228 sq ft240 sq ft133 sq ft201 sq ft67 sq ft56 sq ft76 sq ft139 sq ft49 sq ft40 sq ft56 sq ft76 sq ft23 sq ft23 sq ftOpen BelowHallMedia RoomGuest Suite 2Guest Suite 3Guest Bath 3ClosetStorageUtiltyCraft RoomBalcony 1Guest Bath 2GalleryClosetGalleryShowerShowerLiving Area1687 sq ftBalcony 2SOLID HALF WALLMAINTAIN 6" ABOVE RAKE OF ROOF ADJACENTAND 42" ABOVE FINISHED BALCONY FLOORALUM. COPING CAP ABOVE SIDINGSOLID HALF WALLMAINTAIN 6" ABOVE RAKE OF ROOF ADJACENTAND 42" ABOVE FINISHED BALCONY FLOORALUM. COPING CAP ABOVE SIDING36" VINYL RAILINGSILL @ 60" AFFTEMP GLASSSILL @ 60" AFFTEMP GLASSSILL @ 72" AFFSILL @ 72" AFFSILL @ 24" AFFSILL @ 24" AFFSILL @ 24" AFFSILL @ 24" AFFSILL @ 24" AFFSILL @ 24" AFFSILL @ 24" AFF10' CEILING10' CLG10' CLG10' CLG11' CLG10' CEILING11' CEILING11' CLG10' CLG10' CLG10' CLGTEMP GLASSWCLINENCABINETTEMP GLASSWCLINENCABINET22.5"X54" PULLDOWN STAIRAC#1AC#2RETAIRRETAIR36" WOOD/METAL RAILINGSLOPE 1/2"SLOPE 1/2"SLOPE 2" MINSLOPE 2" MINPROVIDE METAL PAN FLASHING BELOWPROVIDE METALPAN FLASHINGBELOWPROVIDE METALPAN FLASHINGBELOWWCLINENCABINETPwdr Rm11' CLG11' CEILING11' CEILING11' CEILING1) PROFESSIONAL STATEMENT - TO THE BEST OF OUR KNOWLEDGE THESE PLANS ANDSPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLEMINIMUM FIRE SAFETY STANDARDS AS DETERMINED IN ACCORDANCE WITH FLORIDA BUILDING CODE7TH EDITION (2020) RESIDENTIAL, 2017 NEC.2) IMPORTANT NOTE - ALL REFERENCES BY STRUCTURAL AND TRUSS ENGINEERED DRAWINGSSHALL SUPERCEDE ALL NOTES REFERENCES AND CALLOUTS ON THE ARCHITECTURAL PLANS.3) ALL WORK PERFORMED SHALL COMPLY WITH ALL APPLICABLE LOCAL AND STATE BUILDINGCODES, ORDINANCES AND REGULATIONS AND ALL OTHER AUTHORITIES HAVING JURISDICTION.4) MINIMUM DESIGN LOADS FLOOR 40 P.S.F. LIVE LOAD 10 P.S.F. DEAD LOAD ROOF 20 P.S.F. LIVE LOAD 10 P.S.F. DEAD LOAD VERIFY DESIGN LOADS WITH LOCAL BUILDING CODES AND CONDITIONS. REFER TO STRUCTURALENGINEERING FOR ALL STRUCTURAL DETAILS, SPECIFICATIONS AND NOTES.5) CONCRETE A) ALL CONCRETE FOOTINGS ARE DESIGNED TO BEAR ON MINIMUM SOIL PRESSURE OF 3,000 P.S.F.AND SHALL BE PLACED ON FIRM, UNDISTURBED SOIL 6" MINIMUM BELOW GRADE. CONTRACTORSHALL REINFORCE CONCRETE FOOTINGS AND POURED CONCRETE WALLS AS REQUIRED FORSPECIFIC SOIL CONDITIONS OR LOCAL CODES, WHICHEVER IS MORE RESTRICTIVE. B) ALL CONCRETE USED SHALL HAVE COMPRESSIVE STRENGTH OF 3,000 P.S.I. C) PROVIDE MINIMUM 4" CONCRETE COVER AT UNDER SLAB UTILITY LOCATIONS. WHENCONCRETE ENCASEMENT OF UTILITY LINES IS REQUIRED, INCREASE SLAB THICKNESS AT THE UTILITYLINE. D) PROVIDE ISOLATION JOINT MATERIAL BETWEEN FOUNDATION WALLS AND ALL SLABS INCLUDINGPATIO, PORCH AND SIDEWALKS. E) PROVIDE CUT OR TOOLED CONTROL JOINTS WHERE INDICATED ON FOUNDATION PLANS.6) FRAMING A) LAMINATED VENEER LUMBER (LVL) SHALL PROVIDE THE DESIGN VALUES EQUAL TO OREXCEEDING THE FOLLOWING; 2800 PSI IN BENDING Fb, 285 PSI IN HORIZONTAL SHEAR, Fv, 2m PSI INMODULUS OF ELASTICITY, E. B) UNLESS OTHERWISE NOTED, ALL DIMENSION FRAMING LUMBER SHALL HAVE AN ALLOWABLEBENDING STRESS + 875 PSI (1000 PSI REPETITIVE) OR BETTER. C) ALL TRUSSES SHALL BE SECURELY BRACED BOTH DURING ERECTION AND AFTER PERMANENTINSTALLATION IN A BUILDING IN ACCORDANCE WITH COMMENTARY AND RECOMMENDATIONS ASPUBLISHED BY THE TRUSS PLATE INSTITUTE. D) 3/4" HIGH DENSITY T&G PLYWOOD SUBFLOOR GLUED AND NAILED. PANEL SPAN RATING SHALLBE APA 24/32, EXPOSURE 1, WITH SEALED EDGES. INSTALL PER MANUFACTURERS SPACING ANDEDGE RECOMMENDATIONS. E) 1/4" UNDERLAYMENT (MINIMUM) UNDER VINYL OR TILE ON WOOD FRAME FLOOR SYSTEMS. F) MIN 15/32 HIGH DENSITY O.S.B. WOOD ROOF SHEATHING WITH 'H' CLIPS. APA PANEL SPANRATING SHALL BE 24/0, EXPOSURE 1, WITH SEALED EDGES. INSTALL PER MANUFACTURERS SPACINGAND EDGE RECOMMENDATIONS. ROOF SHEATHING TO BE REFLECTIVE FOIL BACKED G) ROOF TRUSS SYSTEMS SHALL BE FABRICATED WITH WOOD CHORDS AND WOOD WEBS INACCORDANCE WITH DESIGNS PREPARED UNDER THE SUPERVISION OF A REGISTEREDPROFESSIONAL ENGINEER. H) ROOF TRUSS MANUFACTURER SHALL SUBMIT 2 SETS OF SEALED SHOP DRAWINGS TO BUILDERFOR APPROVAL OF ROOF TRUSSES AND BEAMS. I) PRESSURE TREATED LUMBER (BORATE) SHALL BE USED WHERE WOOD IS IN CONTACT WITHCONCRETE AND FOR A 2"X4" MUD SILL. J) ALL EXTERIOR DECK CONSTRUCTION SHALL BE WITH PRESSURE TREATED LUMBER (BORATE)WITH DIMENSIONS AS INDICATED ON THE PLANS.7) SIDING & ROOFING A) VAPOR BARRIER SHALL BE APPLIED ON ALL EXTERIOR WALLS. INSTALL AS PERMANUFACTURERS REQUIREMENTS. B) INSTALL 30# (MIN) FELT UNDER ALL SHINGLES. C) NAILS ONLY TO BE USED FOR ROOF SHINGLE ATTACHMENT - NO STAPLES ALLOWED. D) FLASH ALL ROOF TO WALL CONDITIONS.8) INSULATION - PROVIDE R-19 MINIMUM BATT INSULATION IN ALL EXTERIOR WALLS AND R-38 BLOWNINSULATION IN ALL CEILINGS OR RAFTERS ADJACENT TO THE EXTERIOR OR TO UNHEATED SPACES,PLUS R-19 AT EXPOSED FLOORS. ALL INSULATION TO MEET HUD MINIMUM PROPERTY SPECS. R-11BATTS AT FIREPLACE CHASE WALLS AND UNDER FIREPLACE UNIT. PROVIDE MIN. R13 BATT SOUNDINSULATION IN ALL INTERIOR ROOM DIVIDING WALLS AND IN FLOOR STRUCTURE BETWEEN FLOORS.9) DRYWALL A) ALL WALLS TO HAVE 1/2" GYPSUM AND ALL CEILINGS TO HAVE 1/2' CEILING BOARD UNLESSNOTED OTHERWISE. B) USE 'DURAROCK' OR 'DENSHIELD' BACKER BOARD FOR ALL CERAMIC TILE INSTALLATIONS. C) USE WATER RESISTANT GYPSUM BOARD FOR EXPOSED WALLS AND CEILING AT SHOWER ANDTUB WALL AREAS RECEIVING FIBERGLASS ENCLOSURE. D) USE 5/8" FIRE RATED TYPE 'X' GYPSUM BOARD AND PROVIDE A 1 HOUR FIRE SEPARATION FORALL LIVING SPACES ABOVE GARAGE SPACE. E) USE 3/4" RADIUS CORNER BEAD AT REQUESTED LOCATIONs10) DOORS & WINDOWS A) DOOR AND WINDOW INFILTRATION SHALL BE IN ACCORDANCE WITH CURRENT VERSION OF FBCR 2010. AND SHALL MEET PERFORMANCE STANDARDS ANSI/AAMA 101-88 FOR METAL WINDOWS, DH-C40 FOR VINYL WINDOWS AND THE CRF SHALL NOT BE LESS THAN 55. B) PROVIDE INSULATING DOUBLE GLAZING AT ALL EXTERIOR GLASS AREAS AND TEMPERED GLASSIN ALL SLIDING GLASS DOORS AND IN WINDOWS AS PER LOCAL CODES. C) CAULK AT ALL SASH, SLIDING GLASS DOORS, ENTRANCE DOORS AND BOTTOM PLATES (ALLSIDES AND OPENINGS) AND HEAD FLASH ALL WINDOWS AND DOORS AS PER DETAIL ATTACHEDHEREIN. D) ALL SECOND FLOOR EGRESS WINDOWS SHALL HAVE MIN. SILL HEIGHT OF 24" AS PER 613.211) MECHANICAL & ELECTRICAL A) ALL ELECTRICAL AND PLUMBING REQUIREMENTS SHALL COMPLY WITH LOCAL BUILDING CODES. ALL OUTDOOR, BATHROOM AND GARAGE WALL RECEPTACLES SHALL BE PROVIDED WITH GROUNDFAULT CIRCUIT PROTECTION. SERVICE PANELS TO BE (MIN) 20 CIRCUIT, 100 AMP, 110 VOLT. B) PROVIDE MAIN SEWER CLEAN OUT WITHIN 5'-0" INSIDE OR OUTSIDE OF THE BUILDING LINEUNLESS NOTED OTHERWISE. C) WATER SERVICE SHALL BE 1" MINIMUM FROM EACH EXTERIOR SHUT OFF VALVE. D) ALL SHOWER HEAD HEIGHTS TO BE 80" AFF AT FIBERGLASS SHOWERS AND 84" AFF AT CERAMICSHOWERS.GENERAL NOTESSHEETREVAPPROVEDSCALEDATEDRAWN BYSHEET TITLEPLANPROPOSED RESIDENCE FORRBM#401 - 1031 Blanding Blvd. O.P., 32065 (904) 545-3456SECOND FLOOR PLANSCALE 1/4" = 1'-0"GoldwasserSteve & Becky Goldwasser12/14/224SECOND FLOOR PLANDuval Construction 2'-3"10'-2"2'-3"2'-3"10'-2"2'-3"14'-8"12'-4"19'-8"14'-8"61'-4"2'-7"21'-0"23'-8"9'-10"8"12'-1"69'-10"4'-3"2'-0"2'-7"1'-8"15'-0"3'-4"25'-9"5'-0"16'-6"3"2'-10"16'-11"46'-7"20'-8"2'-7"69'-10"9'-10"1'-6"22'-2"17'-4"3'-8"2'-7"13'-0"32'-8"15'-8"61'-4"2'-6"19'-2"11'-0"13'-0"5'-0"11'-3"1'-0"11'-4"4'-0"13'-9"33'-10"13'-9"14'-0"1'-8"31'-8"14'-0"5 1/2"4'-9"8'-0"20'-5"8'-5"13'-8"3'-2"6'-0"15'-11"4"16'-4"4'-0"11'-0"11'-0"10'-8"4'-0"1'-0"1'-0"4'-8"1'-0"1'-0"1'-4"4'-7 1/2"3'-9"4'-7 1/2"AC PADPT FRAMED STEPS WITH SYNTHETIC DECK BOARDS TO GRADE4" STEP DOWN4" STEP DOWNRECESS SLAB 1 1/2" FORSLIDING DOOR TRACKREFER TO MANUFACTURERSSPEC FOR EXACT DIMENSIONSRECESS SLAB 1 1/2" FORSLIDING DOOR TRACKREFER TO MANUFACTURERSSPEC FOR EXACT DIMENSIONSSLOPE SUMMER KITCHEN1" FOR DRAINAGESLOPE GARAGE 2" FOR DRAINAGESLOPE GARAGE 2" FOR DRAINAGESLOPESLOPEFLOOROUTLETFLOOROUTLETRECESSSHOWER3 1/2"MAIN SLAB SPECIFICATION4" MIN. - 3000 PSI POURED CONCRETECW FIBERMIX REINFORCING OVER6 MIL VISQUENE & COMPACTED FILL(REFER TO ENGINEERING FOR FOOTERAND REINFORCING DETAILS)MAIN SLAB SPECIFICATION4" MIN. - 3000 PSI POURED CONCRETECW FIBERMIX REINFORCING OVER6 MIL VISQUENE & COMPACTED FILL(REFER TO ENGINEERING FOR FOOTERAND REINFORCING DETAILS)FOUNDATION WALL SPECIFICATION3 COURSES - 8" CONCRETE BLOCKCW TYPE 'S' HIGH STRENGTH MORTARFILL CELLS SOLID WITH SLAB POUR(REFER TO ENGINEERING FOR FOOTERAND REINFORCING DETAILS)21" STEP DOWN21" STEP DOWNKITCHENISLAND ROUGHIN LOCATIONPT FRAMED DECK WITHSYNTHETIC DECK BOARDSREFER TO ENGINEERINGFOR DETAILSPROVIDE FOOTER FORCOLUMN BEARINGAND BRICK PEDESTALPROVIDE FOOTER FORCOLUMN BEARINGAND BRICK PEDESTALPT FRAMED STEPS WITHSYNTHETIC DECKBOARDS TO GRADEPT FRAMED STEPS WITHSYNTHETIC DECKBOARDS TO GRADE7" STEPDOWN7" STEPDOWN7" STEPDOWN7" STEPDOWN7" STEPDOWN7" STEPDOWN FOUNDATION PLANSCALE 1/4" = 1'-0"SHEETREVAPPROVEDSCALEDATEDRAWN BYSHEET TITLEPLANPROPOSED RESIDENCE FORRBM#401 - 1031 Blanding Blvd. O.P., 32065 (904) 545-3456Goldwasser5FOUNDATION PLANSteve & Becky Goldwasser12/14/22Duval Construction 6 1/2 : 126 1/2 : 124 : 126 1/2 : 126 1/2 : 126 1/2 : 126 1/2 : 126 1/2 : 126 1/2 : 126 1/2 : 126 1/2 : 126 1/2 : 126 1/2 : 126 1/2 : 126 1/2 : 126 1/2 : 126 1/2 : 126 1/2 : 121'-6"1'-6"1'-6"1'-6"1'-6"1'-6"1'-6"1'-6"2'2'2'2'1'-6"1'-6"1'-6"1'-6"1'-6"1'-6"22.5"X54" PULLDOWN STAIRLOWER ATTICACCESSTHROUGHWALLALLOW 30"X30"OPENING FORCHIMNEY CHASER806.1 Ventilation requiredEnclosed attics and enclosed rafter spaces formed where ceilings areapplied directly to the underside of roof rafters shall have cross ventilationfor each separated space by ventilating openings protected against theentrance of rain. Ventilating openings shall be provided with corrosionresistant wire mesh, with 1/16" (3.2 mm) minimum to 1/4 inch (6.4 mm)maximum openings.R806.2 Minimum AreaThe minimum net free ventilating area shall be 1/150 of the area of thevented space.Exception: The minimum net free ventilation area shall be 1/300 of thevented space provided one or more of the following conditions are met:1. In Climate Zones 6, 7 and 8, a Class I or II vapor retarder is installed onthe warm-in-winter side of the ceiling.2. At least 40 percent and not more than 50 percent of the requiredventilating area is provided by ventilators located in the upper portion of theattic or rafter space. Upper ventilators shall be located no more than 3 feet(914 mm) below the ridge or highest point of the space, measured vertically,with the balance of the required ventilation provided by eave or cornicevents. Where the location of wall or roof framing members conflicts with theinstallation of upper ventilators, installation more than 3 feet (914 mm) belowthe ridge or highest point of the space shall be permitted.R806.3 Vent ClearanceWhere eave or cornice vents are installed, insulation shall not block the freeflow of air. A minimum of 1-inch (24.4 mm) space shall be provided betweenthe insulation and the roof sheathing at the location of the vent.ATTIC VENTILATION AREA CALC'SExcerpt of the 7TH Edition Florida Building Code(2020), ResidentialVentilation RequiredAttic 3,703 Square Footage3,703 / 300 = 12.3412.34 x.5 (50%) = 6.17 Square footage net free area req.d4'-0" vent - provides 1.0 sq.ft. net free space6'-0" vent - provides 1.5 sq.ft. net free space8'-0" vent - provides 2.0 sq.ft. net free spaceRoof Vent SpecificationsVents Required(5) 6'-0" vents @ 1.5 sq.ft. = 7.5 7.5 Total sq.ft. net free area provided 2'6'-10 3/4"2'1'-3"3'-10"1'-3"3'-4 3/4"5'-6"8"5'-6"2'4'-8 1/2"6"4'-8 1/2"6"4'-8 1/2"6"4'-8 1/2"1'-6"7'-8"14'-2"4'-6"6"4'-6"6"4'-6"6"4'-6"1'6.5/12 PITCHVAULTED CEILING6.5/12 PITCHVAULTED CEILINGBUILD DOWN CEILING 6" TOALLOW COFFERS TO RECESSBUILD DOWN CEILING 6" TOALLOW COFFERS TO RECESSSTEP UPCEILING 8"22.5"X54"ATTICACCESSROOF PLAN2ND FLOOR CEILINGSCALE 3/16" = 1'-0"SHEETREVAPPROVEDSCALEDATEDRAWN BYSHEET TITLEPLANPROPOSED RESIDENCE FORRBM#401 - 1031 Blanding Blvd. O.P., 32065 (904) 545-3456Goldwasser18" EAVE OVERHANG12" GABLE OVERHANGROOF PLAN / DETAIL6Steve & Becky Goldwasser12/14/22VENTILATION NOTETHIS CALCULATION IS SHOWN FOR REFERENCEONLY - OFF RIDGE VENTING IS NOT REQUIREDWITH THE USE OF OPEN CELL FOAM INSULATIONDuval ConstructionMAIN FLOOR CEILING PLANSCALE 3/16" = 1'-0" DNDNDNUPRRRRRRRRRRAFCIAFCIAFCIAFCIAFCIAFCIAFCIAFCIAFCIAFCIAFCIAFCIAFCIGFCIGFCIGFCIGFCIGFCI WPWPWPGFCI WPGFCI WPGFCI WPGFCI WPGFCI WPGFCI WP34GFCI WP3RRR3CICO/SDSDTVGarageGarageMaster BdrmPorchOfficeEntryWineCellarAC#1AC#2FAN & LIGHTFAN & LIGHTGDOGFCIGDOGFCISWITCH TOLIGHT ABOVETANKLESS GASWATER HEATEROpen DeckRRRRRRAFCIAFCIAFCIAFCIAFCIAFCIAFCIAFCIAFCIAFCIAFCIAFCIGFCIAFCIGFCI WPGFCI WPRRRR33TVAFCIAFCIAFCITVTVOpen BelowGuest Suite 2Guest Suite 3GuCraft RoomBalcony 1ClosetShowerFAN & LIGHTFAN & LIGHTFAN & LIGHTLINENWPR4GFCI3WPDMAAV ControlTDESCRIPTIONSYMBOLELECTRICAL - DATA - AUDIO LEGENDCeiling FanVentilation Fans: Ceiling Mounted, Wall MountedCeiling Mounted Light Fixtures: Surface/Pendant, Recessed, Heat Lamp, Low VoltageWall Mounted Light Fixtures: Flush Mounted, Wall SconceChandelier Light Fixture240V Receptacle110V Receptacles: Duplex, Weather Proof, GFCISwitches: Single Pole, Weather Proof, 3-Way, 4-WaySwitches: Dimmer, TimerAudio Video: Control Panel, SwitchFluorescent Light FixtureELECTRICAL MAINFLOOR PLANSCALE 1/4" = 1'-0"SHEETREVAPPROVEDSCALEDATEDRAWN BYSHEET TITLEPLANPROPOSED RESIDENCE FORRBM#401 - 1031 Blanding Blvd. O.P., 32065 (904) 545-3456GoldwasserELECTRICAL MAIN FLOORSteve & Becky Goldwasser712/14/22ELECTRICAL NOTES1) 95% OF ALL FIXED LIGHT FIXTURES INSIDE AND OUTSIDE HAVE CLF/LED LAMPS.2) THE REQUIRED GFCI OUTLETS (DWELLING UNITS) IN BATHROOMS,KITCHEN COUNTERTOPS, OUTLETS WITHIN 6' OF LAUNDRY, UTILITY WETBAR SINKS, ACCORDING TO NEC 210.3) FOR ATTICS, PROVIDE AT LEAST ONE LIGHTING OUTLET CONTAININGA SWITCH OR CONTROLLED BY A WALL SWITCH SHALL BE INSTALLED. AT LEAST ONE POINT OF CONTROL SHALL BE AT THE USUAL POINT OFENTRY TO THESE SPACES NEC 210.70 (A)(3).4) AFCI PROTECTION - 210.12 (B) DWELLING UNITES. ALL 120 VOLT,SINGLE PHASE, 15 AMP AND 20 AMP BRANCH CIRCUITS SUPPLYINGOUTLETS INSTALLED IN DWELLING UNITES, FAMILY ROOMS, DININGROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS,SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILARROOMS OR AREAS SHALL BE INSTALLED TO PROVIDE PROTECTION OFTHE BRANCH CIRCUIT FBC R3902.12.5) ALL CEILING FAN LOCATIONS SHALL BE PROPERLY BRACED ANDWIRED WITH 3 WIRE TO ALLOW FOR AN ADDITION OF SEPARATE SWITCHFOR FAN AND LIGHT IF NO REMOTE CONTROL IS SUPPLIED.Duval ConstructionELECTRICAL SECONDFLOOR PLANSCALE 1/4" = 1'-0" SHEETREVAPPROVEDSCALEDATEDRAWN BYSHEET TITLEPLANPROPOSED RESIDENCE FORRBM#401 - 1031 Blanding Blvd. O.P., 32065 (904) 545-3456GoldwasserSteve & Becky Goldwasser12/14/22SIDING / WALL SECTIONS8Duval ConstructionHARDIE SIDING DETAILSBRICK VENEER DETAILS SHEETREVAPPROVEDSCALEDATEDRAWN BYSHEET TITLEPLANPROPOSED RESIDENCE FORRBM#401 - 1031 Blanding Blvd. O.P., 32065 (904) 545-3456GoldwasserSteve & Becky Goldwasser12/14/229MISC. DETAILSDuval ConstructionTYPICAL STAIRDETAILNOSCALE4" MAX.RETURN HATO POST OR3 - 2"X12" S10" MIN. + 1 1/4" NOSING7 3/4"MAX.HANDRAIL1 1/4" MIN. DIA.2" MAX. DIA.1 1/2" FROM WALLRETURNHANDRAILSTO POSTOR WALLPRESSURETREATED BOTTOMBEARING PLATE34" - 38"6' - 8"MIN.CLEARANCE