FL42088_R1_AE_PER8598 SS 2023-06-22 Rev. 9-21-23
Hermes F. Norero, P.E.
Florida No. 73778
Product Evaluation Report
of
Panoramic Doors
Coastal Storm Door
(Non-HVHZ) (Non-Impact)
for
Florida Product Approval
FL# FL42088
Report No. 8598
Current Florida Building Code
Method: 1 – A (Certification Mark or Listing)
Category: Exterior Doors
Sub – Category: Swinging Exterior Door Assemblies
Product: Coastal Storm Door
Materials: Aluminum 6063-T6
Product Dimensions: See Installation Instructions, PAD001
Prepared for:
Panoramic Doors
15050 Frye Road
Fort Worth, TX 76155
Prepared by:
Hermes F. Norero, P.E.
Florida Professional Engineer # 73778
Date: 06/12/2023
Contents:
Evaluation Report Pages 1 – 3
FL#: FL42088
Report #: 8598
Date: 06/12/2023
Page 2 of 3
Manufacturer: Panoramic Doors
Product Category: Exterior Doors
Product Sub-Category: Swinging Exterior Door Assemblies
Compliance Method: State Product Approval Method (1)(a)
Product Name: Coastal Storm Door
(Non-HVHZ) (Non-Impact)
Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Panoramic
Doors based on Method 1a of the State of Florida Product Approval, Department of Business
and Professional Regulation - Florida Building Commission.
Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval
process of the product named herein.
This product has been evaluated for use in locations adhering to the current Florida Building
Code.
See Installation Instructions PAD001, signed and sealed by Hermes F. Norero, P.E. (FL # 73778)
for specific use parameters.
Limits of Use:
1. This product has been evaluated and is in compliance with the current Florida Building
Code, excluding the “High Velocity Hurricane Zone” (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment
into substrate material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with
Chapter 16 of the current Florida Building Code and does require an impact resistant
covering.
4. Site conditions that deviate from the details of installation instructions PAD001
require further engineering analysis by a licensed engineer or registered architect.
5. See Installation Instructions PAD001 for size and design pressure limitations.
FL#: FL42088
Report #: 8598
Date: 06/12/2023
Page 3 of 3
Certification Agency: The manufacturer has demonstrated compliance of manufacture of products
in accordance with the Florida Building Code for manufacturing under an
approved certification agency through Keystone Certifications, Inc.
(FBC Organization # CER1523)
Performance Standards: The product described herein has been evaluated per:
• TAS 202-94
Referenced Data:
1. Product Testing performed by Architectural Testing, Inc. (an Intertek
company) - Plano, TX
(FBC Organization # TST1910)
Report #: P9297.01-801-18, Report Date: 04/26/23
Report Signed and Sealed by Tyler Westerling, FL PE No. 72012
Installation:
Refer to Installation Instructions (PAD001) for anchor spacing and more details of the
installation requirements.
Design Pressure:
Refer to Installation Instructions (PAD001) for design pressures based on size, configuration,
and glass types.