FL42088_R1_AE_PER8598 SS 2023-06-22 Rev. 9-21-23 Hermes F. Norero, P.E. Florida No. 73778 Product Evaluation Report of Panoramic Doors Coastal Storm Door (Non-HVHZ) (Non-Impact) for Florida Product Approval FL# FL42088 Report No. 8598 Current Florida Building Code Method: 1 – A (Certification Mark or Listing) Category: Exterior Doors Sub – Category: Swinging Exterior Door Assemblies Product: Coastal Storm Door Materials: Aluminum 6063-T6 Product Dimensions: See Installation Instructions, PAD001 Prepared for: Panoramic Doors 15050 Frye Road Fort Worth, TX 76155 Prepared by: Hermes F. Norero, P.E. Florida Professional Engineer # 73778 Date: 06/12/2023 Contents: Evaluation Report Pages 1 – 3 FL#: FL42088 Report #: 8598 Date: 06/12/2023 Page 2 of 3 Manufacturer: Panoramic Doors Product Category: Exterior Doors Product Sub-Category: Swinging Exterior Door Assemblies Compliance Method: State Product Approval Method (1)(a) Product Name: Coastal Storm Door (Non-HVHZ) (Non-Impact) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Panoramic Doors based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions PAD001, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, excluding the “High Velocity Hurricane Zone” (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does require an impact resistant covering. 4. Site conditions that deviate from the details of installation instructions PAD001 require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions PAD001 for size and design pressure limitations. FL#: FL42088 Report #: 8598 Date: 06/12/2023 Page 3 of 3 Certification Agency: The manufacturer has demonstrated compliance of manufacture of products in accordance with the Florida Building Code for manufacturing under an approved certification agency through Keystone Certifications, Inc. (FBC Organization # CER1523) Performance Standards: The product described herein has been evaluated per: • TAS 202-94 Referenced Data: 1. Product Testing performed by Architectural Testing, Inc. (an Intertek company) - Plano, TX (FBC Organization # TST1910) Report #: P9297.01-801-18, Report Date: 04/26/23 Report Signed and Sealed by Tyler Westerling, FL PE No. 72012 Installation: Refer to Installation Instructions (PAD001) for anchor spacing and more details of the installation requirements. Design Pressure: Refer to Installation Instructions (PAD001) for design pressures based on size, configuration, and glass types.