Loading...
801 ATLANTIC BLVD ROW23-0037 plansHHHHHHHHSCALE HORIZONTAL: VERTICAL: MP:TO MP: SHEET:OF FILE: DATE: ENGINEER: REVISIONS DATE DESCRIPTION INITIAL PROJECT: CLARIFICATION NO.QUANTITY ATLANTIC BEACH, FLORIDAMCImetroACCESS TRANSMISSION SERVICES LLC.OUTSIDE PLANT CONSTRUCTION15 ATLANTIC BEACH, FLORIDA, DUVAL COUNTY 1803BXVR.8_DD SITE NAME: ATLANTIC BEACH, FLORIDA 1803BXVR.8 S.TAMIMI NEPTUNE BCH 001 1 N/A N/A 6/13/2023 LOCATION MAP MAPSCO PAGE #GIS GRID#N.T.S. TABLE OF CONTENTS: COVER SHEET LOCATION MAP CONTACT SHEET GENERAL NOTES/ CLARIFICATION NOTES ABBREVIATIONS SYMBOLS KEY LINE SYMBOLOGY TYPICAL DETAILS CLARIFICATION SUMMARY OUTSIDE PLANT - PLAN OUTSIDE PLANT - PROFILE 1 2 3 4 5 6 7 8-12 13 14 15 N ISSUE DATE: June 13, 2023 CONSTRUCTION SET SITE/BE NFID: 1803BXVR.8 MCImetro ACCESS TRANSMISSION SERVICES, LLC. OUTSIDE PLANT CONSTRUCTION FIBER OPTIC CABLE ROUTE HUB NAME: REMBRANDT TOWERS HODGES HUB ADDRESS: 2701 HODGES BLVD JACKSONVILLE, FL, DUVAL COUNTY EWO NFID: 2303AIVK SITE NAME: NEPTUNE BCH 001 SITE ADDRESS: ROYAL PALMS DR, ATLANTIC BEACH, FL 32233 HHHHHHHHN SCALE HORIZONTAL: VERTICAL: MP:TO MP: SHEET:OF FILE: DATE: ENGINEER: REVISIONS DATE DESCRIPTION INITIAL PROJECT: CLARIFICATION NO.QUANTITY ATLANTIC BEACH, FLORIDAMCImetroACCESS TRANSMISSION SERVICES LLC.OUTSIDE PLANT CONSTRUCTION15 ATLANTIC BEACH, FLORIDA, DUVAL COUNTY 1803BXVR.8_DD SITE NAME: ATLANTIC BEACH, FLORIDA 1803BXVR.8 S.TAMIMI NEPTUNE BCH 001 2 N/A N/A 6/13/2023 STA 0+00 EXISTING VZN HH LAT:30.32462 LONG:-81.40745 JCTI01, 121-124 NODE STA 6+63 2303AIVK 1803BXVR.8 ROYAL PALMS DR ATLANTIC BEACH, FL 32233 PROPOSED 24"X36"X24" VZN HH LAT:30.32473 LONG:-81.40918 JCTI01, 121-124 STA 4+54 EXISTING VZN HH ACPT:HH::501486656 LAT:30.32460 LONG:-81.40888 STA 5+89 EXISTING VZN HH LAT:30.32460 LONG:-81.40932 CONTACT SHEET SCALE HORIZONTAL: VERTICAL: MP:TO MP: SHEET:OF FILE: DATE: ENGINEER: REVISIONS DATE DESCRIPTION INITIAL PROJECT: CLARIFICATION NO.QUANTITY ATLANTIC BEACH, FLORIDAMCImetroACCESS TRANSMISSION SERVICES LLC.OUTSIDE PLANT CONSTRUCTION15 ATLANTIC BEACH, FLORIDA, DUVAL COUNTY 1803BXVR.8_DD SITE NAME: ATLANTIC BEACH, FLORIDA 1803BXVR.8 S.TAMIMI NEPTUNE BCH 001 3 N/A N/A 6/13/2023 VERIZON: ENGINEER: MARVIN FISHER TEL: 904-6335481 FDOT EMAIL: marvin.fisher@verizon.com VITTORIO FERRARA vittorio.ferrara@dot.state.fl.us DANELLA: MANAGER: CLINT DODSON TEL: 904-759-8616 SHERMAN WINDLEY EMAIL: cdodson@danella.com sherman.windley@dot.state.fl.us VICE PRESIDENT: DAN HOWICK TEL: 321-259-6124 EMAIL: DHOWICK@DANELLA.COM CLAY COUNTY CHRIS MAYNOR OSP DESIGNER: SUFFIAN TAMIMI TEL: 321-259-6124 chris.maynor@claycountygov.com EMAIL:STAMIMI@DANELLA.COM UTILITIES: DIRECTOR: L. DERRIK OWENS TEL: 850-435-1755 STATE GOVERNMENT: FDOT-PERMITS UNITS TEL: 850-981-3000 CITY GOVERNMENT: CTY OF ATLANTIC BEACH ST JOHNS COUNTY MICHELLE CLINE EMAIL: MCLINE@SJCFL.US EMERGENCY: 911 SCALE HORIZONTAL: VERTICAL: MP:TO MP: SHEET:OF FILE: DATE: ENGINEER: REVISIONS DATE DESCRIPTION INITIAL PROJECT: CLARIFICATION NO.QUANTITY ATLANTIC BEACH, FLORIDAMCImetroACCESS TRANSMISSION SERVICES LLC.OUTSIDE PLANT CONSTRUCTION15 ATLANTIC BEACH, FLORIDA, DUVAL COUNTY 1803BXVR.8_DD SITE NAME: ATLANTIC BEACH, FLORIDA 1803BXVR.8 S.TAMIMI NEPTUNE BCH 001 4 N/A N/A 6/13/2023 GENERAL NOTES / CLARIFICATION NOTES CONSTRUCTION NOTES 1.ALL CONDUIT WILL BE 2" AND 4" ID SCHEDULE 40 (i.e. PVC OR BSP/GSP, MANUFACTURED SPLIT PVC OR SPLIT BSP/GSP), UNLESS SPECIFIED OTHERWISE. 2.CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES 48 HOURS PRIOR TO CONSTRUCTION ACTIVITY. SEE CONTACT SHEET FOR CONTACT NAME AND TELEPHONE NUMBER. 3.ALL UNDERGROUND OBSTRUCTION, WHEN LOCATED, WILL REQUIRE THE PLACEMENT OF A BURIED CABLE MARKER AND THE PLACEMENT OF 4" MANUFACTURED SPLIT PVC, BSP/GSP OVER OR UNDER EACH OBSTRUCTION. 4.SHORING MAY BE REQUIRED AND SHALL COMPLY TO O.S.H.A. STANDARDS. 5.ALL BURIED CONDUIT/CABLE WILL BE PLACED AT 42" MINIMUM COVER UNLESS SPECIFIED OTHERWISE ON THE CONSTRUCTION DRAWINGS. 6.MECHANICAL PROTECTION SHALL BE REQUIRED ANYTIME A 36" MINIMUM COVER IS UNOBTAINABLE UNLESS SPECIFIED OTHERWISE ON THE CONSTRUCTION DRAWINGS. 7.ALL 90 DEGREE BENDS IN CONDUIT CONSTRUCTION WILL BE A MINIMUM 38.2" RADIUS UNLESS SPECIFIED OTHERWISE. ALL SPLIT CONDUIT BENDS AND SOLID PVC BENDS SHALL REQUIRE CONCRETE ENCASEMENT UNLESS SPECIFIED OTHERWISE. 8.OPERATIONS PERSONNEL TO BE CONTACTED BY THE CONTRACTOR 48 HOURS PRIOR TO CONSTRUCTION. SEE CONTACT SHEET FOR CONTACT NAME AND TELEPHONE NUMBER. 9.ALL STATIONING IS BASED ON AS-BUILT INFORMATION, THEREFORE SOME VARIANCE SHOULD BE ANTICIPATED. ADJUST AS NEEDED. 10.RAILROAD COMMUNICATION AND SIGNAL CABLES TO BE LOCATED PRIOR TO CONSTRUCTION ACTIVITY. RAILROAD TO BE GIVEN 48 HOURS NOTICE PRIOR TO CONSTRUCTION. 11.ALL BURIED CABLE MARKER POST AND HARDWARE PLACED AND/OR REMOVED ON ALL NEW AND EXISTING ROUTES SHALL BE IMPLEMENTED AS FOLLOWS: A.ON THOSE ROUTES THAT ARE CONSIDERED TO BE IN A NORTH TO SOUTH GEOGRAPHICAL ORIENTATION, THE SOUTHERN-MOST SIGN AND POST SHOULD BE REMOVED. *FOR NEW ROUTES BEING CONSTRUCTED, ONE SIGN POST WILL BE PLACED AT THE NORTH END OF EACH HANDHOLE. B.ON THOSE ROUTES THAT ARE CONSIDERED TO BE IN A EAST TO WEST GEOGRAPHICAL ORIENTATION, THE WESTERN-MOST SIGN AND POST SHOULD BE REMOVED. *FOR NEW ROUTES BEING CONSTRUCTED, ONE SIGN POST WILL BE PLACED AT THE EAST END OF EACH HANDHOLE. GENERAL NOTES 1.ALL CONDUIT WILL BE 2" AND 4" ID SCHEDULE 40 (i.e. PVC OR BSP/GSP, MANUFACTURED SPLIT PVC OR SPLIT BSP/GSP), UNLESS SPECIFIED OTHERWISE. 2.CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES 48 HOURS PRIOR TO CONSTRUCTION ACTIVITY. SEE CONTACT SHEET FOR CONTACT NAME AND TELEPHONE NUMBER. 3.ALL UNDERGROUND OBSTRUCTION, WHEN LOCATED, WILL REQUIRE THE PLACEMENT OF A BURIED CABLE MARKER AND THE PLACEMENT OF 4" MANUFACTURED SPLIT PVC, BSP/GSP OVER OR UNDER EACH OBSTRUCTION. 4.SHORING MAY BE REQUIRED AND SHALL COMPLY TO O.S.H.A. STANDARDS. 5.ALL BURIED CONDUIT/CABLE WILL BE PLACED AT 42" MINIMUM COVER UNLESS SPECIFIED OTHERWISE ON THE CONSTRUCTION DRAWINGS. 6.MECHANICAL PROTECTION SHALL BE REQUIRED ANYTIME A 36" MINIMUM COVER IS UNOBTAINABLE UNLESS SPECIFIED OTHERWISE ON THE CONSTRUCTION DRAWINGS. 7.ALL 90 DEGREE BENDS IN CONDUIT CONSTRUCTION WILL BE A MINIMUM 38.2" RADIUS UNLESS SPECIFIED OTHERWISE. ALL SPLIT CONDUIT BENDS AND SOLID PVC BENDS SHALL REQUIRE CONCRETE ENCASEMENT UNLESS SPECIFIED OTHERWISE. 8.OPERATIONS PERSONNEL TO BE CONTACTED BY THE CONTRACTOR 48 HOURS PRIOR TO CONSTRUCTION. SEE CONTACT SHEET FOR CONTACT NAME AND TELEPHONE NUMBER. 9.ALL STATIONING IS BASED ON AS-BUILT INFORMATION, THEREFORE SOME VARIANCE SHOULD BE ANTICIPATED. ADJUST AS NEEDED. 10.RAILROAD COMMUNICATION AND SIGNAL CABLES TO BE LOCATED PRIOR TO CONSTRUCTION ACTIVITY. RAILROAD TO BE GIVEN 48 HOURS NOTICE PRIOR TO CONSTRUCTION. 11.ALL BURIED CABLE MARKER POST AND HARDWARE PLACED AND/OR REMOVED ON ALL NEW AND EXISTING ROUTES SHALL BE IMPLEMENTED AS FOLLOWS: A.ON THOSE ROUTES THAT ARE CONSIDERED TO BE IN A NORTH TO SOUTH GEOGRAPHICAL ORIENTATION, THE SOUTHERN-MOST SIGN AND POST SHOULD BE REMOVED. *FOR NEW ROUTES BEING CONSTRUCTED, ONE SIGN POST WILL BE PLACED AT THE NORTH END OF EACH HANDHOLE. B.ON THOSE ROUTES THAT ARE CONSIDERED TO BE IN A EAST TO WEST GEOGRAPHICAL ORIENTATION, THE WESTERN-MOST SIGN AND POST SHOULD BE REMOVED. *FOR NEW ROUTES BEING CONSTRUCTED, ONE SIGN POST WILL BE PLACED AT THE EAST END OF EACH HANDHOLE. CLARIFICATION NOTES C-100 CONSTRUCTION - NEW UNDERGROUND 1X2" HDPE (BORE/TRENCH/PLOW) C-110 CONSTRUCTION - NEW UNDERGROUND 1X2" HDPE (OPEN CUT/HARDSCAPE) C-120 CONSTRUCTION - NEW UNDERGROUND 1X2" HDPE (MICRO TRENCH) C-200 CONSTRUCTION - EXISTING UNDERGROUND (VZ OWNED/3RD PART) C-300 CONSTRUCTION - AERIAL (NEW/OVERLASH) C-500 CABLE PREP/SPLICING/TESTING (LOOSE TUBE) C-510 CABLE PREP/SPLICING/TESTING (RIBBON) ABBREVIATIONS AHD AHEAD AM AMTRAK APPROX APPROXIMATELY ASPH ASPHALT AVE AVENUE B/L BASELINE BK BACK BLDG BUILDING BORO BOROUGH BRG BRIDGE BSP BLACK STEEL PIPE BUS BUSINESS CBNT CABINET C/L CENTER LINE C/O CLEAN OUT CB CATCH BASIN CC CENTER TO CENTER CIP CAST IRON PIPE CIR CIRCLE CK CREEK CM CENTER TO MATCHLINE CMP CORRUGATED METAL PIPE CO.COUNTY CONC CONCRETE COND CONDUIT CR COUNTY ROUTE CT COURT CTY CITY CULV CULVERT CW CENTER TO WALL D DEEP OR DEPTH DB DEED BOOK DEPT DEPARTMENT DI DROP INLET DIA DIAMETER DIST DISTRICT DR DRIVE DWG DRAWING E EAST E.O.P.EDGE OF PAVEMENT E/R EDGE OF ROAD E/S EDGE OF SIDEWALK E/SHD EDGE OF SHOULDER ELEC ELECTRIC EMH ELECTRIC MANHOLE ENC ENCASED EQ EQUATION EQUIP EQUIPMENT FBR FIBER FC FACE OF CURB FH FIRE HYDRANT FND FOUND FOC FIBER OPTIC CABLE FTA FIBER TRANSMISSION A GALV GALVANIZED GM GAS METER GOVT GOVERNMENT GV GAS VALVE HH HANDHOLE HDPE HIGH DENSITY POLYETHYLENE HWY HIGHWAY INC INLLC.ORATED INT INTERMEDIATE IP IRON PIN JS JUNCTION SPLICE L LOT NUMBER LAT LATITUDE LGTH LENGTH LN LANE LON LONGITUDE LT LEFT M TAX MAP MAX MAXIMUM MC MATCHLINE TO CENTER MH MANHOLE MIN MINIMUM MKR MARKER MON MONUMENT MPG MID POINT GROUND N NORTH N/F NOW OR FORMERLY NO.NUMBER NS NORFOLK SOUTHERN NT NOTE OH OVERHEAD P PARCEL NUMBER P/L PROPERTY LINE PCC PORTLAND CEMENT CONCRETE PG PAGE PI POINT OF INTERSECTION PLCS PLACES PMTR PARKING METER POLY POLYETHYLENE PVC POLYVINYLCHLORIDE R RANGE R/W RIGHT OF WAY RCB REINFORCED CONCRETE BOX RCP REINFORCED CONCRETE PIPE RD ROAD REQD REQUIRED RGS RIGID GALVANIZED STEEL RR RAILROAD RT RIGHT RV RIVER S SOUTH SAN SANITARY SB SPLICE BOX SEC SECTION SEW SEWER SHD SHOULDER SMH SEWER MANHOLE SPL SPLICE SPLMH SPLICE MANHOLE SR STATE ROUTE ST STREET STA STATION STL STEEL STM STORM STR STREAM T-TOWNSHIP ROUTE TR TRAFFIC BOX TEL TELEPHONE TP TEST POINT (WETLAND DELINEATION) TP TRAVERSE POINT TRIB TRIBUTARY TS TRAFFIC SIGNAL TSB TRAFFIC SIGNAL BOX TWP TOWNSHIP TWS TRAFFIC SIGNAL WIRES TYP TYPICAL US UNITED STATES VA VIRGINIA VCP VITRIFIED CLAY PIPE VPP VITRIFIED PLASTIC PIPE VZN VERIZON W WEST OR WIDE W/WITH WH WHITE WM WATER METER WW WALL TO WALL SCALE HORIZONTAL: VERTICAL: MP:TO MP: SHEET:OF FILE: DATE: ENGINEER: REVISIONS DATE DESCRIPTION INITIAL PROJECT: CLARIFICATION NO.QUANTITY ATLANTIC BEACH, FLORIDAMCImetroACCESS TRANSMISSION SERVICES LLC.OUTSIDE PLANT CONSTRUCTION15 ATLANTIC BEACH, FLORIDA, DUVAL COUNTY 1803BXVR.8_DD SITE NAME: ATLANTIC BEACH, FLORIDA 1803BXVR.8 S.TAMIMI NEPTUNE BCH 001 5 N/A N/A 6/13/2023 SYMBOLS NORTH ARROW MARKER-NUMBER STATION-NUMBER OFFSET-DIST MARKER-NUMBER STATION-NUMBER OFFSET-DIST MARKER-NUMBER STATION-NUMBER OFFSET-DIST MARKER-NUMBER STATION-NUMBER OFFSET-DIST 48" DOC FT MIN. DEPTH STA. TO STA. 25+00 25+00 23+00 MARKER POLE RIGHT MARKER POLE LEFT EXISTING MARKER POLE RIGHT EXISTING MARKER POLE LEFT FENCE/GATE MILE POST (LEFT) MILE POST (RIGHT) DEPTH OF COVER DEPTH OF COVER EXTRA DEPTH NOTE ELECTRIC MARKER BALL CAUTION WARNING NOTE HAZARD WARNING NOTE STREAM FLOW LINE COORDINATE TICK MARK STATION TICK MARK IRON PIPE/IRON PIN BENCH MARK MONUMENT (SURFACE) MONUMENT (IN CASE) CENTER LINE PROPERTY LINE WATER METER GAS METER WATER GUARD POST FIRE HYDRANT GAS VALVE PAD MOUNTED TRANSFORMER TRANSMISSION TOWER UTILITY POLE UTILITY POLE ANCHOR TELEPHONE RISER TELEPHONE VAULT TELEPHONE MANHOLE ELECTRICAL BOX SAN. SEWER MANHOLE STORM DRAIN CATCH BASIN STORM DRAIN CULVERT STORM DRAIN MANHOLE STATE HIGHWAY ADMIN. MANHOLE WATER VALVE BUS STOP MAIL BOX RIP RAP ROCKERY SHRUBBERY SIGN TREE (CONIFER) TREE (DECIDUOUS) YARD LIGHT STREET LIGHT ASSEMBLY TRAFFIC SIGNAL POLE FLASHING WARNING SYSTEM JUNCTION BOX R/R CROSSING GATE R/R CROSSING SIGN R/R CROSSING SIGNAL SIGNAL CONTROLLER FOREIGN MARKERS RAILROAD MILE MARKER ELECTRICAL MANHOLE PROPOSED VERIZON HANDHOLE NODE NODE ID SCALE HORIZONTAL: VERTICAL: MP:TO MP: SHEET:OF FILE: DATE: ENGINEER: REVISIONS DATE DESCRIPTION INITIAL PROJECT: CLARIFICATION NO.QUANTITY ATLANTIC BEACH, FLORIDAMCImetroACCESS TRANSMISSION SERVICES LLC.OUTSIDE PLANT CONSTRUCTION15 ATLANTIC BEACH, FLORIDA, DUVAL COUNTY 1803BXVR.8_DD SITE NAME: ATLANTIC BEACH, FLORIDA 1803BXVR.8 S.TAMIMI NEPTUNE BCH 001 6 N/A N/A 6/13/2023 LINE SYMBOLOGY SCALE HORIZONTAL: VERTICAL: MP:TO MP: SHEET:OF FILE: DATE: ENGINEER: REVISIONS DATE DESCRIPTION INITIAL PROJECT: CLARIFICATION NO.QUANTITY ATLANTIC BEACH, FLORIDAMCImetroACCESS TRANSMISSION SERVICES LLC.OUTSIDE PLANT CONSTRUCTION15 ATLANTIC BEACH, FLORIDA, DUVAL COUNTY 1803BXVR.8_DD SITE NAME: ATLANTIC BEACH, FLORIDA 1803BXVR.8 S.TAMIMI NEPTUNE BCH 001 7 N/A N/A 6/13/2023 ABOVE GROUND PIPING BRUSH/TREE LINE CULVERT/DRAIN PIPE CENTERLINE ROAD DRAINAGE FLOWLINE OR STREAM FACE OF CURB EDGE OF STREET/ROAD (PAVED) EDGE OF GRAVEL ROAD FENCE LINE EDGE OF SIDEWALK GUARDRAIL PAVEMENT MARKINGS PROPERTY LINE RAILROAD RIGHT OF WAY LINE LEASED CONDUIT DIRECT BURIED CABLE BURIED CONDUIT CONCRETE ENCASED CATV CATV CATV BOC S/W S/W P/LP/LP/LP/L R/W R/W L L HHSECTION, TOWNSHIP, COUNTY & RANGE LINES EDGE OF WATER, WET LAND CONTOUR LINE CONTOUR INDEX UTILITY - AERIAL ELECTRIC UTILITY - BURIED ELECTRIC UTILITY - FIBER OPTIC TELEPHONE UTILITY - BURIED GAS UTILITY - BURIED SANITARY SEWER UTILITY - BURIED STORM DRAIN UTILITY - AERIAL TELEPHONE UTILITY - BURIED TELEPHONE UTILITY-BURIED CABLE TV UTILITY-AERIAL CABLE TV UTILITY - BURIED WATER WALL - RETAINING PROPOSED FIBER OPTIC CABLE/CONDUIT TRAFFIC SIGNAL WIRES WET LANDS E E E E GAS GAS GAS SAN SAN T RET RET RET RET TS W SD SD =|==|==|==|==|==|==|==|==|==|==|==|==|==|==|==|==|==|==|==|==|==|==|==|= WL WL WL HH SCALE HORIZONTAL: VERTICAL: MP:TO MP: SHEET:OF FILE: DATE: ENGINEER: REVISIONS DATE DESCRIPTION INITIAL PROJECT: CLARIFICATION NO.QUANTITY ATLANTIC BEACH, FLORIDAMCImetroACCESS TRANSMISSION SERVICES LLC.OUTSIDE PLANT CONSTRUCTION15 ATLANTIC BEACH, FLORIDA, DUVAL COUNTY 1803BXVR.8_DD SITE NAME: ATLANTIC BEACH, FLORIDA 1803BXVR.8 S.TAMIMI NEPTUNE BCH 001 8 N.T.S. N.T.S. 6/13/2023 SCALE HORIZONTAL: VERTICAL: MP:TO MP: SHEET:OF FILE: DATE: ENGINEER: REVISIONS DATE DESCRIPTION INITIAL PROJECT: CLARIFICATION NO.QUANTITY ATLANTIC BEACH, FLORIDAMCImetroACCESS TRANSMISSION SERVICES LLC.OUTSIDE PLANT CONSTRUCTION15 ATLANTIC BEACH, FLORIDA, DUVAL COUNTY 1803BXVR.8_DD SITE NAME: ATLANTIC BEACH, FLORIDA 1803BXVR.8 S.TAMIMI NEPTUNE BCH 001 9 N.T.S. N.T.S. 6/13/2023 SCALE HORIZONTAL: VERTICAL: MP:TO MP: SHEET:OF FILE: DATE: ENGINEER: REVISIONS DATE DESCRIPTION INITIAL PROJECT: CLARIFICATION NO.QUANTITY ATLANTIC BEACH, FLORIDAMCImetroACCESS TRANSMISSION SERVICES LLC.OUTSIDE PLANT CONSTRUCTION15 ATLANTIC BEACH, FLORIDA, DUVAL COUNTY 1803BXVR.8_DD SITE NAME: ATLANTIC BEACH, FLORIDA 1803BXVR.8 S.TAMIMI NEPTUNE BCH 001 10 N.T.S. N.T.S. 6/13/2023 Armorcast Products Company reserves the right to update or discontinue product information at any time without notice. www.armorcastprod.com ARMORCAST PRODUCTS COMPANY POLYMER CONCRETEBOXESPOLYMER CONCRETE STANDARD DIMENSIONS A6001974 THIS PRODUCT IS LISTED TO APPLICABLE UL STANDARDS AND REQUIRMENTS BY UL. 1/2” TYP. 24” x 36” BOX ASSEMBLY Tel: (818) 982-3600 Fax: (818) 982-7742 20K LOAD RATING SCALE HORIZONTAL: VERTICAL: MP:TO MP: SHEET:OF FILE: DATE: ENGINEER: REVISIONS DATE DESCRIPTION INITIAL PROJECT: CLARIFICATION NO.QUANTITY ATLANTIC BEACH, FLORIDAMCImetroACCESS TRANSMISSION SERVICES LLC.OUTSIDE PLANT CONSTRUCTION15 ATLANTIC BEACH, FLORIDA, DUVAL COUNTY 1803BXVR.8_DD SITE NAME: ATLANTIC BEACH, FLORIDA 1803BXVR.8 S.TAMIMI NEPTUNE BCH 001 11 N.T.S. N.T.S. 6/13/2023 VARIES FINISHED GRADE MCI MARKER SPLICE HANDHOLE SIGN I.D. NUMBER CALL MCI1-800-624-9675AND THE LOCAL ONE CALL48 HOURS BEFORE DIGGINGIN THIS VICINITY WARNING TUBULAR MARKER 8' STEEL POST DRIVEN 4'-0" INTO GROUND 6'-1.75" 4'-0" 6" SPLICE HANDHOLE COVER NOT SHOWN FOR CLARITY DETAIL "A" PLAN VIEW DETAIL "B-1" C-LOK GROUND ROD INSTALLATION METHOD DETAIL "B" INSTALLATION DETAIL GROUND LOCATIONS FIBER CABLE CONDUIT GROUND ROD 3 WIRES #6 SOLID COLOR CODED FIBER OPTIC CABLE FIBER OPTIC CABLE CONDUIT FIBER CABLE HDPE DUCT FOR HARNESS TEMPORARY GROUNDING BEFORE SPLICING SEE DETAIL "B-3" R&UOW DETAIL "B-3" TEMPORARY GROUNDING (INCLUDING SPURB CABLE) DETAIL "B-2" C-LOK CONNECTOR SPUR FIBER CABLE 1" STAINLESS STEEL HOSE CLAMPS SOUTHWEST FIBER CABLE BLACK WIRE FROM SURGE ARRESTER ATTACH TO RPS OF CABLE YELLOW WIRE FROM SURGE ARRESTER ATTACHED TO RPS OF CABLE BLUE WIRE FROM SURGE ARRESTER ATTACHED TO RPS CABLE HDPE DUCT FOR HARNESS NORTHEAST FIBER CABLE GREEN WIRE TO SURGE ARRESTER (#6 WIRE) CABLE GROUNDING INSTALLATION DETAILS (FOR CONTRACTOR INSTALLATION) NOTE: SEE DETAIL "B-1" THIS SHEET FOR INSTALLATION METHOD. NOTES: 1. OSP CONTRACTOR SHALL INSTALL THE FOLLOWING MCI FURNISHED MATERIALS: ·6' TUBULAR MARKER WITH HARDWARE (1) ·SPLICE HANDHOLE ·GROUND ROD AND FIGURE 8 CONNECTOR ·PULL WIRE HARNESS FROM HANDHOLE TO MARKER 2. THE CONTRACTOR WILL FURNISH AND INSTALL THE HDPE, LENGTH AS REQUIRED PER THE DRAWINGS SUPPLIED. 3. ALL MCI AND CONTRACTOR FURNISHED MATERIALS SHALL BE IN PLACE PRIOR TO PLACEMENT OF THE FIBER OPTIC CABLE, AT WHICH TIME THE TEMPORARY GROUND CONNECTION WILL BE MADE IN ACCORDANCE WITH DETAIL "A'. 4. AFTER CONNECTION OF THE TEMPORARY GROUND, THE CONTRACTOR SHALL SEAL THE ENDS OF THE FIBER OPTIC CABLE TO PREVENT THE ENTRY OF MOISTURE. 5. AFTER INSTALLATION OF THE FIBER OPTIC CABLE AND WIRING HARNESS BY THE CONTRACTOR, THE CONTRACTOR SHALL SEAL ALL DUCT LINE OPENINGS WITH MCI APPROVED MATERIAL TO PREVENT THE ENTRY OF MOISTURE. 6. MARKER AND HANDHOLE SHOULD BE PLACED IN LINE WITH THE NORTHERN CORNER OF THE SPLICE HANDHOLE FOR NORTH/SOUTH ROUTES, THE EASTERN CORNER OF THE SPLICE HANDHOLE FOR EAST/WEST ROUTES. CABLE ROUTE FIBER OPTIC 1. WITH GROUND WIRE IN SMALL GROOVE, HOOK "C" COMPONENT AROUND ROD. 2. INSERT WEDGE COMPONENT BETWEEN ROD AND WIRE. 3. PUSH WEDGE COMPONENT BETWEEN ROD AND WIRE TO SECURE ASSEMBLY. 4. COMPLETE CONNECTION USING PILLARS. 5. ENSURE SECURING LOCK IS VISIBLE IN "INSPECTION WINDOW". SCALE HORIZONTAL: VERTICAL: MP:TO MP: SHEET:OF FILE: DATE: ENGINEER: REVISIONS DATE DESCRIPTION INITIAL PROJECT: CLARIFICATION NO.QUANTITY ATLANTIC BEACH, FLORIDAMCImetroACCESS TRANSMISSION SERVICES LLC.OUTSIDE PLANT CONSTRUCTION15 ATLANTIC BEACH, FLORIDA, DUVAL COUNTY 1803BXVR.8_DD SITE NAME: ATLANTIC BEACH, FLORIDA 1803BXVR.8 S.TAMIMI NEPTUNE BCH 001 12 N.T.S. N.T.S. 6/13/2023 A-1 A-1 TUBULAR MARKER DETAILS CALL 1-800-6AND THE LOC 48 HOURS BEIN THIS MCI 24-9675AL ONE CALL FORE DIGGINGVICINITY SIGN I.D. NUMBER CALL MCI1-800-624-9675AND THE LOCAL ONE CALL48 HOURS BEFORE DIGGINGIN THIS VICINITYWARNINGFIBE R OPTICCABLERO UTE 6" 4'0" 6'-1.75" STEEL POST INSIDE TUBULAR MARKER EXISTING GRADE 8' STEEL POST DRIVEN 4'-0 INTO GROUND 3.75" O.D. 6'0" 3.75" O.D. 1.75" 1'10" 3" 0.50" DIA. BOLT HOLE (BOTH SIDE) SEE SECTION A-1 & DETAIL "D" THIS SHEET THICKNESS MATERIAL 0.125" SLEEVE (WHITE) THICKNESS MATERIAL 0.125" MARKER (ORANGE) TUBULAR MARKER 8' STEEL POST 1.5" BOLT SEE DETAIL "D" 1.5" 0.375"-16 THREADS DETAIL "A"DETAIL "B"DETAIL "C" DETAIL "D" INSTALLATION VIEW FRONT VIEW SIDE VIEW TUBULAR MARKER SECTION A-1 1.5" BOLT 3.75" O.D. 6'0" 3.75" O.D. 1.75" 1'10" 6" 0.50" DIA. BOLT HOLE (BOTH SIDE) SEE SECTION A-1 & DETAIL "D" THIS SHEET THICKNESS MATERIAL 0.125" SIGN I.D. NUMBER CALL MCI 1-800-624-9675AND THE LOCAL ONE CALL48 HOURS BEFORE DIGGING IN THIS VICINITY FIBEROPTICCABLER OUTENUMBER SIGN I.D. W A R N I N G C A B L E R O U T E F I B E R O P T I C SCALE HORIZONTAL: VERTICAL: MP:TO MP: SHEET:OF FILE: DATE: ENGINEER: REVISIONS DATE DESCRIPTION INITIAL PROJECT: CLARIFICATION NO.QUANTITY ATLANTIC BEACH, FLORIDAMCImetroACCESS TRANSMISSION SERVICES LLC.OUTSIDE PLANT CONSTRUCTION15 ATLANTIC BEACH, FLORIDA, DUVAL COUNTY 1803BXVR.8_DD SITE NAME: ATLANTIC BEACH, FLORIDA 1803BXVR.8 S.TAMIMI NEPTUNE BCH 001 13 N.T.S. N.T.S. 6/13/2023 CLARIFICATION SUMMARY SHEET SPAN CLARIFICATION SUMMARY BID UNIT FQNID(s)INSTALL METHOD CALCULATED LENGTH (QUANTITY) BDC-105 OSP:SPANPATH::500981927 BORE 74 TOTAL 74 FIBER CABLE CLARIFICATION SUMMARY BDC-300 FIB:TAIL::500934711 12 COUNT FIBER (INCLUDING SLACK)863 TOTAL 863 STRUCTURE CLARIFICATION SUMMARY BID UNIT FQNIDs DESCRIPTION TOTAL QUANTITY BDC-112 ACPT:HH::502379533 24X36X24 HANDHOLE 1 TOTAL 1 FIBER EQUIPMENT CLARIFICATION SUMMARY BDC-800 FIB:GHT::500612928 12 GHOST TERMINAL 1 TOTAL 1 SPLICE CLOSURE CLARIFICATION SUMMARY BDC-701 FIB:SPLCL::500604974 (2204ACUG) Cable Prep/Splicing/Testing (Loose Tube)4 TOTAL 4 R/W R/W R/W R/W R/WR/WBOC BOC BOC BOC SS SS SS SS SS SS HHHHHHHHBOC BOC BOC BOC BOC BOC W W W W W W BOC BOC BOCBOCBOCBOCBOC BOC ROYAL PALMS DR ATLANTIC BLVD (SR-10)PENMAN RD H CLHHHHHHHHSTA 0+00STA 1+00STA 2+00STA 3+00STA 4+00STA 5+00STA 4+54 EXISTING VZN HH ACPT:HH::501486656 12 CT FIBER FIB:TAIL::500934711 LAT:30.32460 LONG:-81.40888 STA 5+89 EXISTING VZN HH ACPT:HH::501486657 12 CT FIBER FIB:TAIL::500934711 LAT:30.32460 LONG:-81.40932 NODE STA 6+63 2303AIVK 1803BXVR.8 ROYAL PALMS DR ATLANTIC BEACH, FL 32233 PROPOSED 24"X36"X24" VZN HH ACPT:HH::502379533 12 CT FIBER FIB:TAIL::500934711 PLACE 100' SLACK LOOP:SLACK::500812605 1-12CT GHOST TERM FIB:GHT::500612928 LAT:30.32473 LONG:-81.40918 JCTI01, 121-124 EXISTING CONDUIT OSP:UGSPAN::500349091 PULL 12 CT FIBER FIB:TAIL::500934711 663' EXISTING CONDUIT OSP:UGSPAN::500349091 PULL 12 CT FIBER FIB:TAIL::500934711 (663') C-100 PROPOSED 1-2" HDPE CONDUIT AT A MINIMUM DEPTH OF 36" BY DIRECTIONAL BORE OSP:SPANPATH::500981927 74' PULL 12 CT FIBER FIB:TAIL::500934711 (663') STA 0+00 EXISTING VZN HH ACPT:HH::501486655 SPLICE LOCATION EXISTING SPLICE CLOSURE FIB:SPLCL::500604974 (2204ACUG) EXISTING 144 CT FIBER FIB:BUR::500247358 REF # :2204ADBM 12 CT FIBER FIB:TAIL::500934711 PLACE 100' SLACK LOOP:SLACK::500812604 LAT:30.32462 LONG:-81.40745 JCTI01, 121-124 114'34'7'36'CL CL CL CL CL CL CL 107'27'36'14'14'18'18'15'72' 41' 21'21'5'46'EXISTING CONDUIT OSP:UGSPAN::500349091 EXTENDS TO THE WEST 9'2'21'2'HEXISTING 144 CT FIBER FIB:BUR::500247358 REF # :2204ADBM N SCALE HORIZONTAL: VERTICAL: MP:TO MP: SHEET:OF FILE: DATE: ENGINEER: REVISIONS DATE DESCRIPTION INITIAL PROJECT: CLARIFICATION NO.QUANTITY ATLANTIC BEACH, FLORIDAMCImetroACCESS TRANSMISSION SERVICES LLC.OUTSIDE PLANT CONSTRUCTION15 ATLANTIC BEACH, FLORIDA, DUVAL COUNTY 1803BXVR.8_DD SITE NAME: ATLANTIC BEACH, FLORIDA 1803BXVR.8 S.TAMIMI NEPTUNE BCH 001 14 N/A 1:80 6/13/2023 SCALE HORIZONTAL: VERTICAL: MP:TO MP: SHEET:OF FILE: DATE: ENGINEER: REVISIONS DATE DESCRIPTION INITIAL PROJECT: CLARIFICATION NO.QUANTITY ATLANTIC BEACH, FLORIDAMCImetroACCESS TRANSMISSION SERVICES LLC.OUTSIDE PLANT CONSTRUCTION15 ATLANTIC BEACH, FLORIDA, DUVAL COUNTY 1803BXVR.8_DD SITE NAME: ATLANTIC BEACH, FLORIDA 1803BXVR.8 S.TAMIMI NEPTUNE BCH 001 15 N/A #### 6/13/2023 (1) 2" HDPE 3' PROP. DEPTH I.D. 2" DEPTHS PROPOSED ARE MINIMUM DEPTHS. ALL SUBSURFACE UTILITIES SHOWN ARE APPROXIMATE. UTILITY LOCATES WILL BE PERFORMED PRIOR TO CONSTRUCTION. WHEN DIRECTIONAL BORE IS THE METHOD OF INSTALLATION, A MINIMUM OF 24-INCH SEPERATION SHALL BE MAINTAINED FROM ALL EXISTING UTILITIES, ITS/ATMS LINES, AND STORM DRAIN SYSTEMS WHILE MAINTAINING THE MINIMUM REQUIRED DEPTH UNDER PAVEMENT OR NON-PAVED GROUND.