1847 OCEAN GROVE DR ERES23-0221 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP:
SULLIVAN FAMILY BYPASS
TRUST 1847 OCEAN GROVE DR ATLANTIC BEACH FL 32233
COMPANY:ADDRESS:CITY:STATE:ZIP:
PIER ELECTRIC LLC PO Box 1158 Ponte Vedra Beach FL 32004
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
169598 0100 OCEAN GROVE UNIT 02
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
1847 OCEAN GROVE DR ELECTRICAL RESIDENTIAL Vehicle wallbox charger 50
amp breaker, 200 amp panel $2050.00
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
ELEC REPAIRS AND MISC 455-0000-322-1000 0 $35.00
ELEC SWITCH AND RECEPTACLE OUTLETS 455-0000-322-1000 0 $2.00
ELECTRICAL BASE FEE 455-0000-322-1000 0 $55.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 10/10/2023
PERMIT NUMBER
ERES23-0221
ISSUED: 10/10/2023
EXPIRES: 4/7/2024
ELECTRICAL RESIDENTIAL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
TOTAL: $96.00
2 of 2Issued Date: 10/10/2023
PERMIT NUMBER
ERES23-0221
ISSUED: 10/10/2023
EXPIRES: 4/7/2024
ELECTRICAL RESIDENTIAL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
Electrical Permit Application ALL INFORMATION
HIGHLIGHTED IN
City of Atlantic Beach Building Department GRAY IS REQUIRED.
800 Seminole Rd, Atlantic Beach, FL 32233
Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: R2g —C22
JOB ADDRESS: I$4`7 O Cf AN GRrcVC 'DR PROJECT VALUE $ `2.0 SO
IEA INFORMATION REQUIRED ON ALL PERMITS: 200 AMPS "L`1O VOLTS PHASE
NEW SERVICE: 0 Overhead Underground Underground up Pole
1tesidential (Main)Service:
O-100 amps 0101-150amps 0151-200amps amps of Meters
Commercial (Main)Service:
0-100 amps 0101-150amps 0151-200amps Q amps OCT Service amps
Conductor Type Size
Multi-Family(Main)Service:
0-100 amps 0101-150amps 0151-200amps amps of Unit Meters
TEMPORARY POLE: amps
SERVICE UPGRADE: 0 amps OCT Service amps
NEW FEEDER (ADDITIONS, ACCESSORY STRUCTURES, ETC.):
0100 amps 150amps 0200amps amps OCT Service amps
IN ADDITIONS, REMODELS, REPAIRS, BUILD-OUTS, ACCESSORY STRUCTURES, ETC:
Outlets/Switches: 0-30amps 1 31-100amps 101-200amps
Appliances: 0-30amps 31-100amps 101-200amps
A/C Circuits:0-60amps 61-100amps
Heat Circuits:circuits @ kw
Number of Lighting Outlets, Including Fixtures:
OTHER ELECTRICAL PROJECTS:
Swimming Pool Sign Smoke Detectors Qty) ['Transformers KVA ['Motors HP
n FIRE ALARM SYSTEM (Requires 3 sets of plans):
Qty volts/amps
121 REPAIRS/MISCELLANEOUS:
Replace Burnt/Damaged Meter Can ElSafety Inspection Janel Change DOH to UG
Other: ADN SOA CIRGUiT Fac, VMU 1,JALLBox CHARGER Updated10/17/18
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have
read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether
specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of
construction.
Owner Name: SEA-N3 SVLLIWok) Phone Number: q04- 6tO - 9'scc
Electrical Company: P tE R C LELTI,\C. LLC Office Phone: 90L-1 tO 6 $016 Fax:
Co.Address: R'O $OJT 051 POiJTE VCDRA BCAc.N City: State: FL Zip: '32.004
License Holder: VLADIMIR CNE R y ItUI( State Certification/Registration#: FL CC 13O I I 573
Notarized Signature of License Hoick.
The foregoing instrument was acknowledged before me this 2l •ay of 5e iamb&r,20? in th State of Florida,County of
Signature of Notary Public
k.-1
VANESSA ANGERS
MY COMMISSION#HH 244118 [ ] Personally Known OR[vK' dentification
EXPIRES:March 23,2026 Vl(,t L} ty,r C lieTypeofIdentification:1'iekiC(lU lL
V
C14. 11:f • •-• "
4..
A miaettomoa Yt.1 ••• • ,•.
t, 3 if
14 FLOOR
~bRooM ,,
f>Roi>oSct> PLAN FOR_
\ ,
VTILITY
MCT£R.
'
I) ?..OOA LIR<.Urf
I P..R.fA 'ktR
'l..40 .'..110LT
) 4>0A
1
~1ft,.((JIT
8R£A~R ,
~' AW6 t:.U
~IStONNtl-T LOdi-~l.£,,
<
' '=>· ~M\J \Jt.LL..io~ (EVSG)
1 ' f V '-A~ '-1.\'-Rl.,~
I I
' 'I
1
~~~ot.Jy
'"tOOA
f LE C T~IUI L I>.& N{ L
1'8Y7
US SUPPLEMENTAL INSTRUCTIONS:
ACTUAL PANEL FOR US MARKET
In the original manual, the images do not entirely
correspond to the US version of the Wallbox. The US
Version should only contain 2 sets of DIP switches, one
set containing 5 and the other containing 6.
Please note that for this instruction, the set of 5 DIP
switches on the left of the panel are the only ones that
should be referenced. The 6 DIP switches on the right
are not US Market specific and should all be in the “OFF”
(down) position. As seen in the photo.
DIP SWITCH CONFIGURATION
DIP SWITCH 1:
This switch should be in the “OFF” (down) position to
allow free usage.
Note: The “ON” position is not applicable for the US Market.
DIP SWITCH 2:
As this switch is based on the ground configuration of
the home, an electrician is required to determine which
grounding system the home has.
Note: Based on NEC, US grounding is classified TN System
for residential homes.
CONFIGURATION FOR DIP SWITCHES 3-5
Please note that this part of the installation manual is
accurate and should be used for reference
(Section 6.2 Power Settings. Refer to US Part Number)
These DIP switches should be configured based on the
circuit that the electrician set up for the charger.
Example: if the circuit was set up for 40A, then the
configuration of the 3 DIP switches should be in the
“ON” position. As seen on figure 111 (bottom right).
**Please disregard section 7.2 through 7.4 in the BMW
and MINI Wallbox Manual.
Updated 02/2023
61 90 5 A1E 1B3 - BMW WALLBOX (US VERSION)
BMW Wallbox
USER MANUAL.
ORIGINAL BMW ACCESSORIES.
For the US Market, please refer to the part number stated below:
Part Number: 61 90 5 A1E 1B3 (US VERSION)
BMW Wallbox
Instructions for use
Contents
EN1 Information 48
2 Overview 54
3 Requirements 55
4 Installation 58
5 Connect the terminals 62
6 DIP switch settings 64
7 Local load management 68
8 Commissioning 73
9 Operation 74
10 LED display 78
11 Troubleshooting 79
12 Technical data 80
13 Waste disposal 83
47
For the US Market, please refer to the part number stated below:
Part Number: 61 90 5 A1E 1B3 (US VERSION)
1 Information
1.1 Symbols used
!Denotes instructions that draw your attention to dangers.
Denotes instructions that draw your attention to special features.
Denotes the end of the instruction or warning text.
1.2 Important safety information
During use of electrical products, basic precautionary measures must be observed, including
the following instructions:
■Read the safety information and all the instructions carefully and familiarise yourself with
the device before you attempt to install, operate or service it.
■Keep the safety information and instructions and make sure you have access to their
contents at all times.
■This device must only be operated under supervision when children are nearby.
■This device must not be used if the cable is damaged, the insulation is broken, or there is
other damage.
■This device must not be used if the vehicle plug is broken or exhibits cracks or other
damage.
■Danger from electricity. The BMW Wallbox must be installed, commissioned and serviced
by appropriately trained, qualified and authorised electricians (1), who bear full responsibility
for complying with the current standards and installation regulations.
■Please note that vehicles or national regulations may require additional overvoltage
protection. Please refer to your national connection and installation standards.
(1)People who, as a result of their training, skills and experience and their knowledge of the
relevant standards can assess the work and identify possible dangers.
48
■Check that all screw and clamp connections are secure before commissioning the device.
The terminal block must never be left open unattended. Fit the cover on the terminal block
if you leave the BMW Wallbox unattended during the installation work.
■Do not make any unauthorised changes or modifications to the BMW Wallbox.
■You must not carry out any repair work to the BMW Wallbox. Such work may only be
carried out by the manufacturer or a trained expert (for example replacing the BMW
Wallbox).
■Do not remove any identifiers such as safety symbols, warnings, model plates, labels or
cable markings.
■The BMW Wallbox does not have a main switch. The RCCB and circuit breaker on the
building installation are used as the mains isolator.
■Do not pull the vehicle connector plug by the cable; instead use the handle on the vehicle
connector plug to remove it from the vehicle charging socket.
■Ensure that the vehicle connector plug is not mechanically damaged (kinked, jammed, or
run over) and that the contact area does not come into contact with heat sources, dirt or
water.
■Do not touch the contacts on the vehicle connector plug.
■Always carry out an inspection for signs of damage before the charging cycle. Pay
particular attention to dirt and moisture on the vehicle connector plug, cuts in the cable or
chafing areas on the insulation. Ensure that the cable output is firmly secured to the BMW
Wallbox.
■Do not clean the BMW Wallbox with a water jet (hosepipe, pressure washer, etc.).
■Ensure that the BMW Wallbox is not damaged by being handled incorrectly.
■Do not open the cover on the terminal block if the BMW Wallbox is installed outdoors and it
is raining or snowing.
■Danger of breaking the plastic housing (protection class IK09).
■Do not use countersunk screws to secure the device.
■Only tighten the screws to the specified torque.
■The installation surface must be completely level (max. 1 mm difference between the
support and fastening points). Do not bend the housing.
Information for trained personnel who may open the housing: Danger of damage. Electronic
components may be destroyed if touched. Conduct an electrical discharge procedure before handling
modules by touching a metallic, earthed object. If you fail to follow the safety information, there is a risk
of death, injury and damage to the device. The manufacturer cannot accept any liability for resultant
claims.
1.3 CE declaration of conformity
The CE declaration of conformity can be downloaded from the following link.EN49
https://www.bmw.com/supportwallboxgen3
1.4 Declaration of conformity for electromagnetic compatibility: FederalCommunications Commission Part 15
The BMW Wallbox complies with all the specifications from Part 15 of the Federal Communications
Commission. Operating the BMW Wallbox is subject to the following conditions: (1) This device must
not cause any harmful interference, and (2) This device must accept all received interference, including
interference which may cause it to malfunction.
1.5 Information about Directive 2014/94/EU
You must comply with national regulations (for example the Charging Column Regulation in Germany)
for implementing the EU Directive (2014/94/EU) relating to the mandatory technical specifications for
sockets and vehicle couplings for charging electric or plug-in hybrid vehicles in areas accessible to
the general public. This regulation concerns charging points on public property and for example car
parks at business premises or for customers. Charging points in private car ports or on private garage
entrances are not publicly accessible charging points in the sense of the regulation.
1.6 Intended use
The BMW Wallbox is a charging station for indoor and outdoor use for charging electric or plug-in
hybrid vehicles. Do not connect any other devices to it, for example electric tools. The BMW Wallbox
is designed for installation on a wall or column. You must comply with the relevant national regulations
for installing and connecting the BMW Wallbox. The intended use of the device in all cases includes
compliance with the ambient conditions for which this device was developed. The BMW Wallbox was
developed, manufactured, tested and documented on the basis of the relevant safety standards. If you
follow the instructions and safety information for its intended use, the product will not pose any danger
of material damage or to people’s health. This device must be earthed. In the event of an error, the
earth connection will reduce the risk of an electric shock. Follow the instructions in this manual to the
letter. Otherwise, sources of danger may be created or safety equipment may be rendered inoperable.
In addition to the safety information in this manual, you must also comply with the safety and accident
prevention regulations for the specific device.
1.7 About this manual
This manual and the functions described in it are valid for devices of the following type: BMW Wallbox:
■61 90 5 A1E 1B1
■61 90 5 A1E 1B2
■61 90 5 A1E 1B3 US VERSION
50
■61 90 5 A1E 1B4
■61 90 5 A1E 1B5
The illustrations and explanations contained in this manual refer to a typical version of the device. Your
version of the device may differ from this.EN51
1.8 Package
A Mounting template
B Mounting bracket
C Cable holder
D Housing cover
E Wood screws No. 8 (4 x)
F Torx T30 fastening screws (4 x)
G Stud bolts 1/4" (3x)
H Torx T20 security screw
I Safety guide
52
1.9 Warranty
Further information about the warranty terms and conditions is available from BMW Service. However,
the following cases are not covered by the warranty.
■Defects or damage caused by installation work not carried out as described in this
document.
■Defects or damage caused by using the product for purposes other than those described
in this document.
■Costs and damage caused by repair work not carried out by an electrician authorised by a
BMW sales outlet or an authorised service workshop.EN53
2 Overview
2.1 Displays and controls
■61 90 5 A1E 1B1
■61 90 5 A1E 1B2
■61 90 5 A1E 1B3 US VERSION
■61 90 5 A1E 1B5
■61 90 5 A1E 1B4
1. Housing cover
2. Vehicle plug connector holder
3. Vehicle plug connector (L)/Charging socket
with shutter (R)
4. LED display
5. Terminal block cover
6. Mounting bracket
7. Cable holder
54
3 Requirements
3.1 General criteria for site selection
The BMW Wallbox is designed for indoor and outdoor use. Therefore, it must be ensured that the site
you select complies with the installation conditions and provides suitable protection for the device.
■Ensure that you comply with local regulations for electrical installations, fire safety and accident
prevention as well as keeping local rescue and escape routes clear.
■Do not install the BMW Wallbox at locations:
- Which are used as escape and rescue routes,
- Which are inside zones where there is an explosion risk,
- At which the BMW Wallbox is exposed to ammonia or ammonia gases,
- At which the BMW Wallbox may be damaged by falling objects,
- At which the BMW Wallbox is on a footpath used by people who may trip over the connected
vehicle connector plug,
- At which the BMW Wallbox may be struck by a water jet,
- At which the installation surface does not have the requisite capacity to withstand the mechanical
stresses.
■If possible, install the BMW Wallbox so that it is not exposed to direct sunlight to prevent excessive
temperatures on components of the BMW Wallbox reducing the charging current or interrupting
the charging cycle.
■Ensure that the ambient temperatures comply with the specifications, see section entitled
“Technical Data”.
■Ensure that you comply with the national and international installation standards and regulations.
3.2 Specifications for the electrical connection
When it is delivered, the BMW Wallbox is set to a maximum charging current of 6 A. Ensure that you
set the maximum current for the installed circuit breaker using the DIP switch (see section entitled
“Power settings”).EN55
3.3 Choice of RCCB
The connection cable must be wired into the existing building installation and comply with the national
statutory regulations. For versions
■61 90 5 A1E 1B1
■61 90 5 A1E 1B4
the following considerations must be made:
■Every BMW Wallbox must be connected using its own residual-current-operated circuit breaker
(RCCB). No other circuits may be connected to this RCCB.
■RCCB at least type A (30 mA trip current).
■Additional measures have been taken in the device to protect it from a direct current (DC) error
(> 6 mA DC).
■These measures satisfy the requirements of IEC 62955. This means that there is no general
necessity to use a residual current device (RCD) type B, unless one is explicitly required by the
applicable installation regulations.
3.4 Choice of circuit breaker
When selecting the circuit breaker, you must also take into account the increased ambient
temperatures in the control cabinet. In certain circumstances, this may require the charging current
to be reduced to increase the system’s availability. Set the rated current to suit the required charging
capacity, the available connecting rating and the details on the model plate.
An RCD type B (40 A min. and 400 V min.) must be used for the following versions:
■61 90 5 A1E 1B1
■61 90 5 A1E 1B2
■61 90 5 A1E 1B4
An RCD type B (50 A min. and 250 V min.) must be used for the following versions:
■61 90 5 A1E 1B3 US VERSION
■61 90 5 A1E 1B5
56
These instructions apply to Canada:
Caution: To reduce the risk of fire, only connect the Wallbox to an electrical circuit with the
necessary overcurrent protection for the branch circuit in accordance with National Electrical
Code, ANSI/NFPA 70 and the Canadian Electrical Code, Part I, C22.1.
The required conditions are:
Rated current 40 A
Circuit breaker design 50 A
3.5 Choice of connection cable
When selecting the connection cable, take into account the possible reduction factors and increased
ambient temperatures in the BMW Wallbox’s internal connection zone, see temperature details for
the connection terminals. In certain circumstances, this may require the cable cross-section to be
increased and the temperature resistance of the connection cable to be adjusted.
3.6 Mains isolator
The BMW Wallbox does not have a main switch. The RCCB and circuit breaker on the building
installation are used as the mains isolator.EN57
4 Installation
4.1 Installation requirements
■Comply with the local installation regulations.
■Acclimatisation: If there is a temperature difference of more than 15 °C between transport and
the selected installation site, the BMW Wallbox must be allowed to acclimatise unopened for at
least two hours. Opening the BMW Wallbox immediately may result in condensation forming in its
interior and causing damage when the device is switched on. In certain circumstances, damage
caused by condensation formation may also not appear until after the installation. Ideally, the BMW
Wallbox should be stored for several hours at the installation site before installation. If this is not
possible, the BMW Wallbox should not be stored in low temperatures (< 5 °C) overnight outdoors
or in a vehicle.
4.2 List of tools
■Measuring tool and pen
■Drill
■Torx T30 screwdriver
■Torx T20 security screwdriver
■Cross-head screwdriver No. 2
■Crimping tools
4.3 Recommended installation site
When selecting the installation site, consider access from the charging socket to the vehicle and the
direction in which the vehicle is normally parked.
58
4.4 Required spacing
Refer to the illustration below for choosing the installation site.EN59
4.5 Install the BMW Wallbox
1. The product is a stationary, wall-mounted
device. It contains a mounting template to mark
the screw positions for the mounting bracket
and the optional cable holder.
2. Secure the mounting bracket to the wall.
We recommend the following screw types:
- Masonry walls:
Countersunk screws 1/4". Tightening torque:
8.8 Nm (78 lb in)
- Drywalls supported by wooden posts:
Wood screws No. 8, at least 2” in length.
Tightening torque:
3 Nm (26 lb in)
3. Align the screw holes using the mounting
bracket and product.
4. Install and secure the product on the
mounting bracket using the Torx T30 screws
supplied.
Tightening torque: 1.5 Nm (13 lb in)
60
4.6 Remove the covers
5. Remove the housing cover.
6. Use a T20 screwdriver to remove the screws
which secure the terminal block cover.
Tightening torque: 1.4 Nm (12 lb in)
7. Remove the terminal block cover.
4.7 Secure the anti-theft screw
8. Secure the anti-theft screw.EN61
5 Connect the terminals
Use a suitable cable with wire-end ferrules.
■61 90 5 A1E 1B1
■61 90 5 A1E 1B2
■61 90 5 A1E 1B4
■61 90 5 A1E 1B3 US VERSION
■61 90 5 A1E 1B5
Note: It is also possible to use
a single-phase connection for
the BMW Wallbox. To do so,
connect terminals L1, N and
PE.
The stripping length of the
input cable must be selected
in accordance with the
specifications printed in the
Wallbox.
Connect each terminal to the
correct connection on the input
terminal strip. Then secure
the terminal for the input cable
correctly.
Note: Select a suitable cable
to comply with all current local,
state and national regulations
and standards for electrical
systems. Ensure that the circuit
breaker is switched off before
installation.
This product must be connected
to a permanent, earthed, metal
wiring system, or a device earth
conductor must be routed with
the lines and connected to the
device earth terminal or earthing
conductor.
62
5.1 Input X1 (optional)
Connect the cable to connection X1.
The enabling input is designed for use with a
floating contact. The enabling input allows the
Wallbox to be controlled by external components.
Note: The safe isolation of dangerous voltages must be guaranteed.EN63
6 DIP switch settings
6.1 Setting the earth system
TN system setting (default)TT/IT system setting
64
6.2 Power settings
When it is delivered, the BMW Wallbox is set to a maximum charging current of 6 A.
The following settings apply to these versions:
■61 90 5 A1E 1B1 ■61 90 5 A1E 1B2 ■61 90 5 A1E 1B4
Configuration Max. rated current Configuration Max. rated current
000 0 A 100 16 A
001 6 A 101 20 A
010 10 A 110 24 A
011 12 A 111 32 A EN65
The following settings apply to these versions:
US VERSION ■61 90 5 A1E 1B3 ■61 90 5 A1E 1B5
Configuration Max. rated current Configuration Max. rated current
000 0 A 100 20 A
001 6 A 101 24 A
010 12 A 110 32 A
011 16 A 111 40 A
66
6.3 Authorisation settings
The BMW Wallbox is set at the factory so that all charging cycles must be authorised using an app. If
you do not wish to have to authorise every charging cycle and enable free access to the BMW Wallbox
at all times, the DIP switch must be set to “OFF” (see figure on the right)
Default setting: Access to the BMW Wallbox and Free access to the BMW Wallbox without
authorisation by app before each charging cycle.charging cycle authorisation by app only.
Note: On the date of the sales launch,
authorisation via the app will only be available in
China. Its launch in other countries is currently
being planned.EN67
7 Local load management
7.1 Connection of external energy meters
Connect the external energy meter to enable you to monitor your home connection.
Connect the shielded, twisted connection cable
(> 0.5 mm², max. 30 m) to the RS485 interface.
Pin definition:
A (Rx/ Tx+): Pin 4
B (Rx/ Tx-): Pin 5
The following energy meters are compatible with the Wallbox:
■Schneider Electric A9MEM3150
■Siemens 7KT1665
■Janitza B23 312-10 J
68
■61 90 5 A1E 1B1
■61 90 5 A1E 1B2
■61 90 5 A1E 1B4
■61 90 5 A1E 1B3 US VERSION
■61 90 5 A1E 1B5
Connect the meter to the power
supply. Refer to the specific
instructions supplied in the
meter’s operating instructions.
7.2 Phase assignment
The phase assignment between the Wallbox and household connection can be set using DIP
switches.
The phase assignment between the Wallbox and household connection/meter can be set using DIP
switches 2 and 3 EN69
DIP switch setting Phase assignment
household
connection/meter
-> Wallbox
Configuration Phase assignment
household
connection/meter
-> Wallbox
00 L1 -> L1
L2 -> L2
L3 -> L3
10 L3 -> L1
L1 -> L2
L2 -> L3
01 L2 -> L1
L3 -> L2
L1 -> L3
70
7.3 Function to monitor asymmetric loads
The maximum current value for an asymmetric load can be defined using DIP switches 4 and 5.
DIP switch setting Maximum current DIP switch setting Maximum current
00 Function to monitor
asymmetric loads
disabled (factory
setting)
10 16A
01 10A 11 20A EN71
7.4 Household connection monitor
The limit value for the size of the household connection can be defined using DIP switches 6 to 9.
DIP switch setting Maximum current DIP switch setting Maximum current
0000 Local load
management
disabled (factory
setting)
0110 80A
0001 20A 0111 100A
0010 25A 1000 125A
0011 35A 1001 150A
0100 50A 1010 200A
0101 63A
72
8 Commissioning
Install the terminal block cover
Tightening torque: 1.0 Nm (8.7 lb in)
Install and lock the housing cover.EN73
9 Operation
The BMW Wallbox is supplied as standard with its access control by app enabled. Please change the
DIP switch setting if you do not wish to use access control by app. Further information is available in
section “5.3 Authorisation settings”.
Note: On the date of the sales launch, the app will only be available in China. Its launch in other
countries is currently being planned.
9.1 Starting the charging cycle with access control enabled
1. Connect the vehicle connection plug to the vehicle charging socket.
2. Use the app to authorise and start the charging cycle.
74
9.2 Stopping the charging cycle with access control enabled
1. Stop the charging cycle on the vehicle or using the app.
2. Disconnect the vehicle connection plug from the vehicle charging socket.
3. Place the vehicle connection plug back into the cable holder on the BMW Wallbox.ENote: Further information about ending the charging cycle is available in your vehicle owner’s manual.
9.3 Starting the charging cycle with access control disabled
1. Connect the vehicle connection plug to the vehicle charging socket.
2. The vehicle will start the charging cycle automatically.N75
9.4 Stopping the charging cycle with access control disabled
1. Stop the charging cycle on the vehicle.
2. Disconnect the vehicle connection plug from the vehicle charging socket.
3. Place the vehicle connection plug back into the cable holder on the BMW Wallbox.
Note: Further information about ending the charging cycle is available in your vehicle owner’s manual.
76
9.5 Wallbox service app
Your installer or BMW service partner can use the service and installation app to configure the device,
download the charging history and diagnostic data, update the firmware and rectify errors. The DIP
switch must be set correctly (see section 5 DIP switch settings) to use Wallbox service app. The app is
available in all relevant app stores.
Functions:
■Charging history
■Installation guide
■Power settings
■Firmware update
■Diagnostic data
■Device restart
Wallbox service app
iOS
Wallbox service app
Android
Wallbox service app
China
Wallbox service app
Baidu EN77
10 LED display
LED display Status
No display BMW Wallbox has no power supply.
Blue, from left to right continuously BMW Wallbox initialisation process running.
Blue, steady Vehicle is not connected.
Wallbox is ready to charge.
Ready status.
Blue, slow-moving Vehicle charging.
Green, flashing (1x)User login or authorisation successful.
Red, flashing (1x)User login or authorisation failed.
Red, steady Error.
Red, right-hand LED element Bluetooth module failed.
78
11 Troubleshooting
Situation Action
LED display has no power 1. No supply voltage – check the RCCB and circuit breaker and switch
them on if necessary.
2. Error on the BMW Wallbox – contact your local dealer.
supply.
The charging cycle is not 1. The vehicle connection plug has not been inserted correctly –
remove the vehicle connection plug and reconnect it.
2. The vehicle has been programmed so that the charging cycle starts
at a later time.
3. The vehicle does not require any power – check the vehicle status.
4. The app connection is not working correctly.
started.
The vehicle connection plug
cannot be disconnected.
The charging cycle has not been ended by the vehicle.
LED display lit in red.1. Switch off the supply voltage to the BMW Wallbox using the
appropriate mains isolator.
2. Disconnect the vehicle connecting plug and switch on the supply
voltage again.
3. If the situation persists, contact your local dealer.EN79
12 Technical data
Part number 61 90 5 A1E
1B1
61 90 5 A1E
1B2
61 90 5 A1E
1B4
61 90 5 A1E
1B5
Vehicle
connection plug
Type 2 plug GB/T plug SAE J1772
plug
Type 2 shutter SAE J1772
plug
Input/Output
values
220-240 V/
380-415 V,
32 A,
50-60 Hz,
three-phase
220-240 V,
32 A,
50-60 Hz,
single-phase
220-240 V/
380-415 V,
32 A,
50-60 Hz,
three-phase
220-240 V,
32 A,
50-60 Hz,
single-phase
240 V, 40 A,
60 Hz, single-
phase
220-240 V/
380-415 V,
32 A,
50-60 Hz,
three-phase
220-240 V,
32 A,
50-60 Hz,
single-phase
240 V, 40 A,
50-60 Hz,
single-phase
Input wiring L1, L2, L3, N,
PE
L1, L2, L3, N,
PE
L1, L2, PE L1, L2, L3, N,
PE
L1, N, PE
Earthing system TT/ TN/ IT
Rated current
(rated current can
be adjusted using
DIP switch)
0 A,
6 A,
10 A,
12 A,
16 A,
20 A,
24 A,
32 A
0 A,
6 A,
10 A,
12 A,
16 A,
20 A,
24 A,
32 A
0 A,
6 A,
12 A,
16 A,
20 A,
24 A,
32 A,
40 A
0 A,
6 A,
10 A,
12 A,
16 A,
20 A,
24 A,
32 A
0 A,
6 A,
12 A,
16 A,
20 A,
24 A,
32 A,
40 A
Cable length 5 m 5 m 25 ft N/A 5 m
Cable feed Surface-
mounted
Surface-
mounted
Surface-
mounted
N/A Surface-
mounted
Minimum
connection cross-
section
3 x 6 mm²3 x 6 mm²6 AWG 3 x 6 mm²6 AWG
80
US VERSION
61 90 5 A1E
1B3
Part number 61 90 5 A1E
1B1
61 90 5 A1E
1B2
61 90 5 A1E
1B4
61 90 5 A1E
1B5
Internal fault
current detection
Alternating
current:
15~30 mA
Direct current:
3~6 mA
Alternating
current:
15~30 mA
Direct current:
3~6 mA
Alternating
current:
20 mA
Alternating
current:
15~30 mA
Direct current:
3~6 mA
Alternating
current:
20 mA
Protection against
electric shock
Class II
Housing ingress
protection
(for indoors and
outdoors)
IP65 IP65 NEMA 3S IP65 IP65
Dimensions
(W x H x D)
270x370x185 mm
Weight 6 kg 6 kg 8 kg 6 kg 6 kg
Electrical
protection from
Overcurrent, short-circuit, overvoltage,
undervoltage, earth faults, excess temperature.EN81
US VERSION
61 90 5 A1E
1B3
Interfaces
Display LED
ooth
Ambient conditions
Operating temperature -40 °C ~ +50 °C
Communication Bluet
Temperature properties This is not a safety device, it is only a function. The specified
operating temperature range must not be exceeded. The device
supplies the charging current continuously within the specified
operating temperature ranges. To increase the charging availability,
the charging current is reduced from 32 A to 24 A, 16 A and 6 A if the
temperature is exceeded. After this, the charging cycle may also be
shut down. Once the temperature has dropped, the charging cycle is
continued and the charging current is adjusted to the configuration.
Storage temperature -40 ºC to +80 ºC
Humidity 95 % relative humidity, non-condensing
Height 3,000 m
Natural coolingCooling
Impact protection IK09
Overvoltage category OVC III
Action after a power outage Random delay between 5 and 100 seconds before the charging cycle
is restarted after a power outage
Note: The available charging capacity depends on the vehicle, infrastructure and general
settings.
82
13 Waste disposal
After it has been decommissioned correctly, have the device disposed
of by the Service Department in compliance with current waste
disposal regulations.
Electrical and electronic devices and the accessories must be
disposed of separately from general household waste. Information
about this is provided on the product, in the instructions for use or on
the packaging.
The materials may be recycled as shown by the symbols. You can
make a major contribution to protecting our environment by reusing,
recycling the material or other forms of recycling end-of-life devices.EN83
01 29 5 A35 723 09/2022 (V/Z) 3.0