Loading...
1847 OCEAN GROVE DR ERES23-0221 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: SULLIVAN FAMILY BYPASS TRUST 1847 OCEAN GROVE DR ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: PIER ELECTRIC LLC PO Box 1158 Ponte Vedra Beach FL 32004 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169598 0100 OCEAN GROVE UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1847 OCEAN GROVE DR ELECTRICAL RESIDENTIAL Vehicle wallbox charger 50 amp breaker, 200 amp panel $2050.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT ELEC REPAIRS AND MISC 455-0000-322-1000 0 $35.00 ELEC SWITCH AND RECEPTACLE OUTLETS 455-0000-322-1000 0 $2.00 ELECTRICAL BASE FEE 455-0000-322-1000 0 $55.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 10/10/2023 PERMIT NUMBER ERES23-0221 ISSUED: 10/10/2023 EXPIRES: 4/7/2024 ELECTRICAL RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 TOTAL: $96.00 2 of 2Issued Date: 10/10/2023 PERMIT NUMBER ERES23-0221 ISSUED: 10/10/2023 EXPIRES: 4/7/2024 ELECTRICAL RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Electrical Permit Application ALL INFORMATION HIGHLIGHTED IN City of Atlantic Beach Building Department GRAY IS REQUIRED. 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: R2g —C22 JOB ADDRESS: I$4`7 O Cf AN GRrcVC 'DR PROJECT VALUE $ `2.0 SO IEA INFORMATION REQUIRED ON ALL PERMITS: 200 AMPS "L`1O VOLTS PHASE NEW SERVICE: 0 Overhead Underground Underground up Pole 1tesidential (Main)Service: O-100 amps 0101-150amps 0151-200amps amps of Meters Commercial (Main)Service: 0-100 amps 0101-150amps 0151-200amps Q amps OCT Service amps Conductor Type Size Multi-Family(Main)Service: 0-100 amps 0101-150amps 0151-200amps amps of Unit Meters TEMPORARY POLE: amps SERVICE UPGRADE: 0 amps OCT Service amps NEW FEEDER (ADDITIONS, ACCESSORY STRUCTURES, ETC.): 0100 amps 150amps 0200amps amps OCT Service amps IN ADDITIONS, REMODELS, REPAIRS, BUILD-OUTS, ACCESSORY STRUCTURES, ETC: Outlets/Switches: 0-30amps 1 31-100amps 101-200amps Appliances: 0-30amps 31-100amps 101-200amps A/C Circuits:0-60amps 61-100amps Heat Circuits:circuits @ kw Number of Lighting Outlets, Including Fixtures: OTHER ELECTRICAL PROJECTS: Swimming Pool Sign Smoke Detectors Qty) ['Transformers KVA ['Motors HP n FIRE ALARM SYSTEM (Requires 3 sets of plans): Qty volts/amps 121 REPAIRS/MISCELLANEOUS: Replace Burnt/Damaged Meter Can ElSafety Inspection Janel Change DOH to UG Other: ADN SOA CIRGUiT Fac, VMU 1,JALLBox CHARGER Updated10/17/18 Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Owner Name: SEA-N3 SVLLIWok) Phone Number: q04- 6tO - 9'scc Electrical Company: P tE R C LELTI,\C. LLC Office Phone: 90L-1 tO 6 $016 Fax: Co.Address: R'O $OJT 051 POiJTE VCDRA BCAc.N City: State: FL Zip: '32.004 License Holder: VLADIMIR CNE R y ItUI( State Certification/Registration#: FL CC 13O I I 573 Notarized Signature of License Hoick. The foregoing instrument was acknowledged before me this 2l •ay of 5e iamb&r,20? in th State of Florida,County of Signature of Notary Public k.-1 VANESSA ANGERS MY COMMISSION#HH 244118 [ ] Personally Known OR[vK' dentification EXPIRES:March 23,2026 Vl(,t L} ty,r C lieTypeofIdentification:1'iekiC(lU lL V C14. 11:f • •-• " 4.. A miaettomoa Yt.1 ••• • ,•. t, 3 if 14 FLOOR ~bRooM ,, f>Roi>oSct> PLAN FOR_ \ , VTILITY MCT£R. ' I) ?..OOA LIR<.Urf I P..R.fA 'ktR 'l..40 .'..110LT ) 4>0A 1 ~1ft,.((JIT 8R£A~R , ~' AW6 t:.U ~IStONNtl-T LOdi-~l.£,, < ' '=>· ~M\J \Jt.LL..io~ (EVSG) 1 ' f V '-A~ '-1.\'-Rl.,~ I I ' 'I 1 ~~~ot.Jy '"tOOA f LE C T~IUI L I>.& N{ L 1'8Y7 US SUPPLEMENTAL INSTRUCTIONS: ACTUAL PANEL FOR US MARKET In the original manual, the images do not entirely correspond to the US version of the Wallbox. The US Version should only contain 2 sets of DIP switches, one set containing 5 and the other containing 6. Please note that for this instruction, the set of 5 DIP switches on the left of the panel are the only ones that should be referenced. The 6 DIP switches on the right are not US Market specific and should all be in the “OFF” (down) position. As seen in the photo. DIP SWITCH CONFIGURATION DIP SWITCH 1: This switch should be in the “OFF” (down) position to allow free usage. Note: The “ON” position is not applicable for the US Market. DIP SWITCH 2: As this switch is based on the ground configuration of the home, an electrician is required to determine which grounding system the home has. Note: Based on NEC, US grounding is classified TN System for residential homes. CONFIGURATION FOR DIP SWITCHES 3-5 Please note that this part of the installation manual is accurate and should be used for reference (Section 6.2 Power Settings. Refer to US Part Number) These DIP switches should be configured based on the circuit that the electrician set up for the charger. Example: if the circuit was set up for 40A, then the configuration of the 3 DIP switches should be in the “ON” position. As seen on figure 111 (bottom right). **Please disregard section 7.2 through 7.4 in the BMW and MINI Wallbox Manual. Updated 02/2023 61 90 5 A1E 1B3 - BMW WALLBOX (US VERSION) BMW Wallbox USER MANUAL. ORIGINAL BMW ACCESSORIES. For the US Market, please refer to the part number stated below: Part Number: 61 90 5 A1E 1B3 (US VERSION) BMW Wallbox Instructions for use Contents EN1 Information 48 2 Overview 54 3 Requirements 55 4 Installation 58 5 Connect the terminals 62 6 DIP switch settings 64 7 Local load management 68 8 Commissioning 73 9 Operation 74 10 LED display 78 11 Troubleshooting 79 12 Technical data 80 13 Waste disposal 83 47 For the US Market, please refer to the part number stated below: Part Number: 61 90 5 A1E 1B3 (US VERSION) 1 Information 1.1 Symbols used !Denotes instructions that draw your attention to dangers. Denotes instructions that draw your attention to special features. Denotes the end of the instruction or warning text. 1.2 Important safety information During use of electrical products, basic precautionary measures must be observed, including the following instructions: ■Read the safety information and all the instructions carefully and familiarise yourself with the device before you attempt to install, operate or service it. ■Keep the safety information and instructions and make sure you have access to their contents at all times. ■This device must only be operated under supervision when children are nearby. ■This device must not be used if the cable is damaged, the insulation is broken, or there is other damage. ■This device must not be used if the vehicle plug is broken or exhibits cracks or other damage. ■Danger from electricity. The BMW Wallbox must be installed, commissioned and serviced by appropriately trained, qualified and authorised electricians (1), who bear full responsibility for complying with the current standards and installation regulations. ■Please note that vehicles or national regulations may require additional overvoltage protection. Please refer to your national connection and installation standards. (1)People who, as a result of their training, skills and experience and their knowledge of the relevant standards can assess the work and identify possible dangers. 48 ■Check that all screw and clamp connections are secure before commissioning the device. The terminal block must never be left open unattended. Fit the cover on the terminal block if you leave the BMW Wallbox unattended during the installation work. ■Do not make any unauthorised changes or modifications to the BMW Wallbox. ■You must not carry out any repair work to the BMW Wallbox. Such work may only be carried out by the manufacturer or a trained expert (for example replacing the BMW Wallbox). ■Do not remove any identifiers such as safety symbols, warnings, model plates, labels or cable markings. ■The BMW Wallbox does not have a main switch. The RCCB and circuit breaker on the building installation are used as the mains isolator. ■Do not pull the vehicle connector plug by the cable; instead use the handle on the vehicle connector plug to remove it from the vehicle charging socket. ■Ensure that the vehicle connector plug is not mechanically damaged (kinked, jammed, or run over) and that the contact area does not come into contact with heat sources, dirt or water. ■Do not touch the contacts on the vehicle connector plug. ■Always carry out an inspection for signs of damage before the charging cycle. Pay particular attention to dirt and moisture on the vehicle connector plug, cuts in the cable or chafing areas on the insulation. Ensure that the cable output is firmly secured to the BMW Wallbox. ■Do not clean the BMW Wallbox with a water jet (hosepipe, pressure washer, etc.). ■Ensure that the BMW Wallbox is not damaged by being handled incorrectly. ■Do not open the cover on the terminal block if the BMW Wallbox is installed outdoors and it is raining or snowing. ■Danger of breaking the plastic housing (protection class IK09). ■Do not use countersunk screws to secure the device. ■Only tighten the screws to the specified torque. ■The installation surface must be completely level (max. 1 mm difference between the support and fastening points). Do not bend the housing. Information for trained personnel who may open the housing: Danger of damage. Electronic components may be destroyed if touched. Conduct an electrical discharge procedure before handling modules by touching a metallic, earthed object. If you fail to follow the safety information, there is a risk of death, injury and damage to the device. The manufacturer cannot accept any liability for resultant claims. 1.3 CE declaration of conformity The CE declaration of conformity can be downloaded from the following link.EN49 https://www.bmw.com/supportwallboxgen3 1.4 Declaration of conformity for electromagnetic compatibility: FederalCommunications Commission Part 15 The BMW Wallbox complies with all the specifications from Part 15 of the Federal Communications Commission. Operating the BMW Wallbox is subject to the following conditions: (1) This device must not cause any harmful interference, and (2) This device must accept all received interference, including interference which may cause it to malfunction. 1.5 Information about Directive 2014/94/EU You must comply with national regulations (for example the Charging Column Regulation in Germany) for implementing the EU Directive (2014/94/EU) relating to the mandatory technical specifications for sockets and vehicle couplings for charging electric or plug-in hybrid vehicles in areas accessible to the general public. This regulation concerns charging points on public property and for example car parks at business premises or for customers. Charging points in private car ports or on private garage entrances are not publicly accessible charging points in the sense of the regulation. 1.6 Intended use The BMW Wallbox is a charging station for indoor and outdoor use for charging electric or plug-in hybrid vehicles. Do not connect any other devices to it, for example electric tools. The BMW Wallbox is designed for installation on a wall or column. You must comply with the relevant national regulations for installing and connecting the BMW Wallbox. The intended use of the device in all cases includes compliance with the ambient conditions for which this device was developed. The BMW Wallbox was developed, manufactured, tested and documented on the basis of the relevant safety standards. If you follow the instructions and safety information for its intended use, the product will not pose any danger of material damage or to people’s health. This device must be earthed. In the event of an error, the earth connection will reduce the risk of an electric shock. Follow the instructions in this manual to the letter. Otherwise, sources of danger may be created or safety equipment may be rendered inoperable. In addition to the safety information in this manual, you must also comply with the safety and accident prevention regulations for the specific device. 1.7 About this manual This manual and the functions described in it are valid for devices of the following type: BMW Wallbox: ■61 90 5 A1E 1B1 ■61 90 5 A1E 1B2 ■61 90 5 A1E 1B3 US VERSION 50 ■61 90 5 A1E 1B4 ■61 90 5 A1E 1B5 The illustrations and explanations contained in this manual refer to a typical version of the device. Your version of the device may differ from this.EN51 1.8 Package A Mounting template B Mounting bracket C Cable holder D Housing cover E Wood screws No. 8 (4 x) F Torx T30 fastening screws (4 x) G Stud bolts 1/4" (3x) H Torx T20 security screw I Safety guide 52 1.9 Warranty Further information about the warranty terms and conditions is available from BMW Service. However, the following cases are not covered by the warranty. ■Defects or damage caused by installation work not carried out as described in this document. ■Defects or damage caused by using the product for purposes other than those described in this document. ■Costs and damage caused by repair work not carried out by an electrician authorised by a BMW sales outlet or an authorised service workshop.EN53 2 Overview 2.1 Displays and controls ■61 90 5 A1E 1B1 ■61 90 5 A1E 1B2 ■61 90 5 A1E 1B3 US VERSION ■61 90 5 A1E 1B5 ■61 90 5 A1E 1B4 1. Housing cover 2. Vehicle plug connector holder 3. Vehicle plug connector (L)/Charging socket with shutter (R) 4. LED display 5. Terminal block cover 6. Mounting bracket 7. Cable holder 54 3 Requirements 3.1 General criteria for site selection The BMW Wallbox is designed for indoor and outdoor use. Therefore, it must be ensured that the site you select complies with the installation conditions and provides suitable protection for the device. ■Ensure that you comply with local regulations for electrical installations, fire safety and accident prevention as well as keeping local rescue and escape routes clear. ■Do not install the BMW Wallbox at locations: - Which are used as escape and rescue routes, - Which are inside zones where there is an explosion risk, - At which the BMW Wallbox is exposed to ammonia or ammonia gases, - At which the BMW Wallbox may be damaged by falling objects, - At which the BMW Wallbox is on a footpath used by people who may trip over the connected vehicle connector plug, - At which the BMW Wallbox may be struck by a water jet, - At which the installation surface does not have the requisite capacity to withstand the mechanical stresses. ■If possible, install the BMW Wallbox so that it is not exposed to direct sunlight to prevent excessive temperatures on components of the BMW Wallbox reducing the charging current or interrupting the charging cycle. ■Ensure that the ambient temperatures comply with the specifications, see section entitled “Technical Data”. ■Ensure that you comply with the national and international installation standards and regulations. 3.2 Specifications for the electrical connection When it is delivered, the BMW Wallbox is set to a maximum charging current of 6 A. Ensure that you set the maximum current for the installed circuit breaker using the DIP switch (see section entitled “Power settings”).EN55 3.3 Choice of RCCB The connection cable must be wired into the existing building installation and comply with the national statutory regulations. For versions ■61 90 5 A1E 1B1 ■61 90 5 A1E 1B4 the following considerations must be made: ■Every BMW Wallbox must be connected using its own residual-current-operated circuit breaker (RCCB). No other circuits may be connected to this RCCB. ■RCCB at least type A (30 mA trip current). ■Additional measures have been taken in the device to protect it from a direct current (DC) error (> 6 mA DC). ■These measures satisfy the requirements of IEC 62955. This means that there is no general necessity to use a residual current device (RCD) type B, unless one is explicitly required by the applicable installation regulations. 3.4 Choice of circuit breaker When selecting the circuit breaker, you must also take into account the increased ambient temperatures in the control cabinet. In certain circumstances, this may require the charging current to be reduced to increase the system’s availability. Set the rated current to suit the required charging capacity, the available connecting rating and the details on the model plate. An RCD type B (40 A min. and 400 V min.) must be used for the following versions: ■61 90 5 A1E 1B1 ■61 90 5 A1E 1B2 ■61 90 5 A1E 1B4 An RCD type B (50 A min. and 250 V min.) must be used for the following versions: ■61 90 5 A1E 1B3 US VERSION ■61 90 5 A1E 1B5 56 These instructions apply to Canada: Caution: To reduce the risk of fire, only connect the Wallbox to an electrical circuit with the necessary overcurrent protection for the branch circuit in accordance with National Electrical Code, ANSI/NFPA 70 and the Canadian Electrical Code, Part I, C22.1. The required conditions are: Rated current 40 A Circuit breaker design 50 A 3.5 Choice of connection cable When selecting the connection cable, take into account the possible reduction factors and increased ambient temperatures in the BMW Wallbox’s internal connection zone, see temperature details for the connection terminals. In certain circumstances, this may require the cable cross-section to be increased and the temperature resistance of the connection cable to be adjusted. 3.6 Mains isolator The BMW Wallbox does not have a main switch. The RCCB and circuit breaker on the building installation are used as the mains isolator.EN57 4 Installation 4.1 Installation requirements ■Comply with the local installation regulations. ■Acclimatisation: If there is a temperature difference of more than 15 °C between transport and the selected installation site, the BMW Wallbox must be allowed to acclimatise unopened for at least two hours. Opening the BMW Wallbox immediately may result in condensation forming in its interior and causing damage when the device is switched on. In certain circumstances, damage caused by condensation formation may also not appear until after the installation. Ideally, the BMW Wallbox should be stored for several hours at the installation site before installation. If this is not possible, the BMW Wallbox should not be stored in low temperatures (< 5 °C) overnight outdoors or in a vehicle. 4.2 List of tools ■Measuring tool and pen ■Drill ■Torx T30 screwdriver ■Torx T20 security screwdriver ■Cross-head screwdriver No. 2 ■Crimping tools 4.3 Recommended installation site When selecting the installation site, consider access from the charging socket to the vehicle and the direction in which the vehicle is normally parked. 58 4.4 Required spacing Refer to the illustration below for choosing the installation site.EN59 4.5 Install the BMW Wallbox 1. The product is a stationary, wall-mounted device. It contains a mounting template to mark the screw positions for the mounting bracket and the optional cable holder. 2. Secure the mounting bracket to the wall. We recommend the following screw types: - Masonry walls: Countersunk screws 1/4". Tightening torque: 8.8 Nm (78 lb in) - Drywalls supported by wooden posts: Wood screws No. 8, at least 2” in length. Tightening torque: 3 Nm (26 lb in) 3. Align the screw holes using the mounting bracket and product. 4. Install and secure the product on the mounting bracket using the Torx T30 screws supplied. Tightening torque: 1.5 Nm (13 lb in) 60 4.6 Remove the covers 5. Remove the housing cover. 6. Use a T20 screwdriver to remove the screws which secure the terminal block cover. Tightening torque: 1.4 Nm (12 lb in) 7. Remove the terminal block cover. 4.7 Secure the anti-theft screw 8. Secure the anti-theft screw.EN61 5 Connect the terminals Use a suitable cable with wire-end ferrules. ■61 90 5 A1E 1B1 ■61 90 5 A1E 1B2 ■61 90 5 A1E 1B4 ■61 90 5 A1E 1B3 US VERSION ■61 90 5 A1E 1B5 Note: It is also possible to use a single-phase connection for the BMW Wallbox. To do so, connect terminals L1, N and PE. The stripping length of the input cable must be selected in accordance with the specifications printed in the Wallbox. Connect each terminal to the correct connection on the input terminal strip. Then secure the terminal for the input cable correctly. Note: Select a suitable cable to comply with all current local, state and national regulations and standards for electrical systems. Ensure that the circuit breaker is switched off before installation. This product must be connected to a permanent, earthed, metal wiring system, or a device earth conductor must be routed with the lines and connected to the device earth terminal or earthing conductor. 62 5.1 Input X1 (optional) Connect the cable to connection X1. The enabling input is designed for use with a floating contact. The enabling input allows the Wallbox to be controlled by external components. Note: The safe isolation of dangerous voltages must be guaranteed.EN63 6 DIP switch settings 6.1 Setting the earth system TN system setting (default)TT/IT system setting 64 6.2 Power settings When it is delivered, the BMW Wallbox is set to a maximum charging current of 6 A. The following settings apply to these versions: ■61 90 5 A1E 1B1 ■61 90 5 A1E 1B2 ■61 90 5 A1E 1B4 Configuration Max. rated current Configuration Max. rated current 000 0 A 100 16 A 001 6 A 101 20 A 010 10 A 110 24 A 011 12 A 111 32 A EN65 The following settings apply to these versions: US VERSION ■61 90 5 A1E 1B3 ■61 90 5 A1E 1B5 Configuration Max. rated current Configuration Max. rated current 000 0 A 100 20 A 001 6 A 101 24 A 010 12 A 110 32 A 011 16 A 111 40 A 66 6.3 Authorisation settings The BMW Wallbox is set at the factory so that all charging cycles must be authorised using an app. If you do not wish to have to authorise every charging cycle and enable free access to the BMW Wallbox at all times, the DIP switch must be set to “OFF” (see figure on the right) Default setting: Access to the BMW Wallbox and Free access to the BMW Wallbox without authorisation by app before each charging cycle.charging cycle authorisation by app only. Note: On the date of the sales launch, authorisation via the app will only be available in China. Its launch in other countries is currently being planned.EN67 7 Local load management 7.1 Connection of external energy meters Connect the external energy meter to enable you to monitor your home connection. Connect the shielded, twisted connection cable (> 0.5 mm², max. 30 m) to the RS485 interface. Pin definition: A (Rx/ Tx+): Pin 4 B (Rx/ Tx-): Pin 5 The following energy meters are compatible with the Wallbox: ■Schneider Electric A9MEM3150 ■Siemens 7KT1665 ■Janitza B23 312-10 J 68 ■61 90 5 A1E 1B1 ■61 90 5 A1E 1B2 ■61 90 5 A1E 1B4 ■61 90 5 A1E 1B3 US VERSION ■61 90 5 A1E 1B5 Connect the meter to the power supply. Refer to the specific instructions supplied in the meter’s operating instructions. 7.2 Phase assignment The phase assignment between the Wallbox and household connection can be set using DIP switches. The phase assignment between the Wallbox and household connection/meter can be set using DIP switches 2 and 3 EN69 DIP switch setting Phase assignment household connection/meter -> Wallbox Configuration Phase assignment household connection/meter -> Wallbox 00 L1 -> L1 L2 -> L2 L3 -> L3 10 L3 -> L1 L1 -> L2 L2 -> L3 01 L2 -> L1 L3 -> L2 L1 -> L3 70 7.3 Function to monitor asymmetric loads The maximum current value for an asymmetric load can be defined using DIP switches 4 and 5. DIP switch setting Maximum current DIP switch setting Maximum current 00 Function to monitor asymmetric loads disabled (factory setting) 10 16A 01 10A 11 20A EN71 7.4 Household connection monitor The limit value for the size of the household connection can be defined using DIP switches 6 to 9. DIP switch setting Maximum current DIP switch setting Maximum current 0000 Local load management disabled (factory setting) 0110 80A 0001 20A 0111 100A 0010 25A 1000 125A 0011 35A 1001 150A 0100 50A 1010 200A 0101 63A 72 8 Commissioning Install the terminal block cover Tightening torque: 1.0 Nm (8.7 lb in) Install and lock the housing cover.EN73 9 Operation The BMW Wallbox is supplied as standard with its access control by app enabled. Please change the DIP switch setting if you do not wish to use access control by app. Further information is available in section “5.3 Authorisation settings”. Note: On the date of the sales launch, the app will only be available in China. Its launch in other countries is currently being planned. 9.1 Starting the charging cycle with access control enabled 1. Connect the vehicle connection plug to the vehicle charging socket. 2. Use the app to authorise and start the charging cycle. 74 9.2 Stopping the charging cycle with access control enabled 1. Stop the charging cycle on the vehicle or using the app. 2. Disconnect the vehicle connection plug from the vehicle charging socket. 3. Place the vehicle connection plug back into the cable holder on the BMW Wallbox.ENote: Further information about ending the charging cycle is available in your vehicle owner’s manual. 9.3 Starting the charging cycle with access control disabled 1. Connect the vehicle connection plug to the vehicle charging socket. 2. The vehicle will start the charging cycle automatically.N75 9.4 Stopping the charging cycle with access control disabled 1. Stop the charging cycle on the vehicle. 2. Disconnect the vehicle connection plug from the vehicle charging socket. 3. Place the vehicle connection plug back into the cable holder on the BMW Wallbox. Note: Further information about ending the charging cycle is available in your vehicle owner’s manual. 76 9.5 Wallbox service app Your installer or BMW service partner can use the service and installation app to configure the device, download the charging history and diagnostic data, update the firmware and rectify errors. The DIP switch must be set correctly (see section 5 DIP switch settings) to use Wallbox service app. The app is available in all relevant app stores. Functions: ■Charging history ■Installation guide ■Power settings ■Firmware update ■Diagnostic data ■Device restart Wallbox service app iOS Wallbox service app Android Wallbox service app China Wallbox service app Baidu EN77 10 LED display LED display Status No display BMW Wallbox has no power supply. Blue, from left to right continuously BMW Wallbox initialisation process running. Blue, steady Vehicle is not connected. Wallbox is ready to charge. Ready status. Blue, slow-moving Vehicle charging. Green, flashing (1x)User login or authorisation successful. Red, flashing (1x)User login or authorisation failed. Red, steady Error. Red, right-hand LED element Bluetooth module failed. 78 11 Troubleshooting Situation Action LED display has no power 1. No supply voltage – check the RCCB and circuit breaker and switch them on if necessary. 2. Error on the BMW Wallbox – contact your local dealer. supply. The charging cycle is not 1. The vehicle connection plug has not been inserted correctly – remove the vehicle connection plug and reconnect it. 2. The vehicle has been programmed so that the charging cycle starts at a later time. 3. The vehicle does not require any power – check the vehicle status. 4. The app connection is not working correctly. started. The vehicle connection plug cannot be disconnected. The charging cycle has not been ended by the vehicle. LED display lit in red.1. Switch off the supply voltage to the BMW Wallbox using the appropriate mains isolator. 2. Disconnect the vehicle connecting plug and switch on the supply voltage again. 3. If the situation persists, contact your local dealer.EN79 12 Technical data Part number 61 90 5 A1E 1B1 61 90 5 A1E 1B2 61 90 5 A1E 1B4 61 90 5 A1E 1B5 Vehicle connection plug Type 2 plug GB/T plug SAE J1772 plug Type 2 shutter SAE J1772 plug Input/Output values 220-240 V/ 380-415 V, 32 A, 50-60 Hz, three-phase 220-240 V, 32 A, 50-60 Hz, single-phase 220-240 V/ 380-415 V, 32 A, 50-60 Hz, three-phase 220-240 V, 32 A, 50-60 Hz, single-phase 240 V, 40 A, 60 Hz, single- phase 220-240 V/ 380-415 V, 32 A, 50-60 Hz, three-phase 220-240 V, 32 A, 50-60 Hz, single-phase 240 V, 40 A, 50-60 Hz, single-phase Input wiring L1, L2, L3, N, PE L1, L2, L3, N, PE L1, L2, PE L1, L2, L3, N, PE L1, N, PE Earthing system TT/ TN/ IT Rated current (rated current can be adjusted using DIP switch) 0 A, 6 A, 10 A, 12 A, 16 A, 20 A, 24 A, 32 A 0 A, 6 A, 10 A, 12 A, 16 A, 20 A, 24 A, 32 A 0 A, 6 A, 12 A, 16 A, 20 A, 24 A, 32 A, 40 A 0 A, 6 A, 10 A, 12 A, 16 A, 20 A, 24 A, 32 A 0 A, 6 A, 12 A, 16 A, 20 A, 24 A, 32 A, 40 A Cable length 5 m 5 m 25 ft N/A 5 m Cable feed Surface- mounted Surface- mounted Surface- mounted N/A Surface- mounted Minimum connection cross- section 3 x 6 mm²3 x 6 mm²6 AWG 3 x 6 mm²6 AWG 80 US VERSION 61 90 5 A1E 1B3 Part number 61 90 5 A1E 1B1 61 90 5 A1E 1B2 61 90 5 A1E 1B4 61 90 5 A1E 1B5 Internal fault current detection Alternating current: 15~30 mA Direct current: 3~6 mA Alternating current: 15~30 mA Direct current: 3~6 mA Alternating current: 20 mA Alternating current: 15~30 mA Direct current: 3~6 mA Alternating current: 20 mA Protection against electric shock Class II Housing ingress protection (for indoors and outdoors) IP65 IP65 NEMA 3S IP65 IP65 Dimensions (W x H x D) 270x370x185 mm Weight 6 kg 6 kg 8 kg 6 kg 6 kg Electrical protection from Overcurrent, short-circuit, overvoltage, undervoltage, earth faults, excess temperature.EN81 US VERSION 61 90 5 A1E 1B3 Interfaces Display LED ooth Ambient conditions Operating temperature -40 °C ~ +50 °C Communication Bluet Temperature properties This is not a safety device, it is only a function. The specified operating temperature range must not be exceeded. The device supplies the charging current continuously within the specified operating temperature ranges. To increase the charging availability, the charging current is reduced from 32 A to 24 A, 16 A and 6 A if the temperature is exceeded. After this, the charging cycle may also be shut down. Once the temperature has dropped, the charging cycle is continued and the charging current is adjusted to the configuration. Storage temperature -40 ºC to +80 ºC Humidity 95 % relative humidity, non-condensing Height 3,000 m Natural coolingCooling Impact protection IK09 Overvoltage category OVC III Action after a power outage Random delay between 5 and 100 seconds before the charging cycle is restarted after a power outage Note: The available charging capacity depends on the vehicle, infrastructure and general settings. 82 13 Waste disposal After it has been decommissioned correctly, have the device disposed of by the Service Department in compliance with current waste disposal regulations. Electrical and electronic devices and the accessories must be disposed of separately from general household waste. Information about this is provided on the product, in the instructions for use or on the packaging. The materials may be recycled as shown by the symbols. You can make a major contribution to protecting our environment by reusing, recycling the material or other forms of recycling end-of-life devices.EN83 01 29 5 A35 723 09/2022 (V/Z) 3.0