755 Amberjack Ln ROOF23-0070 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP:
STANFORD RICHARD 755 AMBERJACK LA ATLANTIC BEACH FL 32233
COMPANY:ADDRESS:CITY:STATE:ZIP:
QUALITY DISCOUNT
ROOFING LLC 3481 ST. AUGUSTINE ROAD JACKSONVILLE FL 32207
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
171198 0000 ROYAL PALMS UNIT 01
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
755 AMBERJACK LN ROOF NON SHINGLE Re-Roof Metal $16584.30
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL
Notes:
a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved. All roofing projects require an In-
Progress Inspection. Sheathing installation and replacement guidelines per APA. Underlayment must conform to FBC-R Table 905.1.1. Shingles must
conform to ASTM D3161 G or H, or ASTM D7158
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 10/12/2023
PERMIT NUMBER
ROOF23-0070
ISSUED: 10/12/2023
EXPIRES: 4/9/2024
ROOF NON SHINGLE PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
BUILDING PERMIT 455-0000-322-1000 0 $135.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $67.50
STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.79
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.53
TOTAL: $258.82
2 of 2Issued Date: 10/12/2023
PERMIT NUMBER
ROOF23-0070
ISSUED: 10/12/2023
EXPIRES: 4/9/2024
ROOF NON SHINGLE PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
Final Plumbing
Final Electrical
Final HVAC
CC Final
Final Building*
Swimming Pool Steel
Swimming Pool Safety
Electrical Grounding & Bonding
Swimming Pool Final (Bldg)
Swimming Pool Final (PW)
Formed Columns/ Beams*
Masonry Cell Fill
Structural Steel*
OTHER:
OTHER:
OTHER:
OTHER:
OTHER:
Power Pole
Silt Fence
Piers/ Stem Walls
Underground Plumbing
Underground Electric
Foundation/ Footing
Slab**
Retaining Wall Footing
Driveway
Sewer (Building Dept)
Sewer Tap (Utilities Dept)
Rough Electric*
Rough Plumbing/ Top Out*
Rough Mechanical*
House Wrap
Wall Sheathing
Roof Sheathing
Tie-down Framing Connections
Rough Framing
Roofing In Progress
Window/Door In-Progress
Insulation Ceiling
Insulation Wall
Exterior Lath
Stucco Scratch Coat
Exterior Siding In-Progress
Brick Flashing & Ties
Early Power
Gas Rough
Gas Final*
* When all rough electric, plumbing, mechanical are complete but before any work is
covered up.
* When all gas piping is complete and wallboard is installed but before gas is
attached to any appliance. All outlets must be capped and pipe pressurized at a
minimum of 15 lbs.
* For new living space: When all construction work including electrical, plumbing,
mechanical, exterior finish, grading, required paving and landscaping is complete
and the building is ready for occupancy, but before being occupied
Additional inspections may apply to your project if your project
contains these elements:
INSPECTIONS REQUIRED FOR BUILDING PERMITS
To verify compliance with building codes, inspections of the work authorized are required at various points of the construction.
The following inspections are typically required for residential projects:
Date: Initial: Date: Initial:
_____________________________________________________
Permit Type
____________________________________________________
Permit No.
__________________________________________________________
Job Address
____________________________________________________
Contractor
POST THIS CARD WITH PERMITS AND PERMIT
DOCUMENTATION IN FRONT OF BUILDING
Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends
Building Department Public Works/Utilities Fire Department
Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789
Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203
* When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all
electrical, plumbing and mechanical work is in place, but before concrete is poured.
* When all structural steel members are in place and all connections are complete,
but before such work is covered or concealed.
** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION
Re-Roof Metal
755 AMBERJACK LN
QUALITY DISCOUNT ROOFING LLC
ROOF23-0070
ROOF23-0070
Metal Roof Certification & Listing Program
Certification Report
11030-002-KCI
Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by
the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or
suitability of a product for a given use.
Division: 07 00 00 – Thermal & Moisture Protection
Section: 07 41 13 – Metal roof and wall panels
This Certification Report was used to qualify
Florida Product Approval FL 24397-R6.
145 Limekiln Road, Suite 100B Issue Dated: 10/27/2017
New Cumberland, PA 17070 Revision Date: 1/11/2021
www.keystonecerts.com Expiration Date: 10/12/2025
Construction Specifications Institute (CSI) Category:
1. Program Licensee:
1st Coast Metal Roofing Supply
186 SR 207
East Palatka, FL 32131
386-325-0242
http://www.1stcoastmrs.com/
2. Certified Roof Covering:
1st Coast Metal Roofing Supply’s Model Armour Rib 29
Ga. non-structural through-fastened metal roof and wall
panels installed over plywood sheathing roof deck for
use in new construction, re-roofing and re-covering
applications.
3. Scope of Certification:
This Certification Report provides technical data
substantiating that the use of the certified roof covering
and the evaluated roof systems are in compliance with
the following:
• 2020 Florida Building Code - Building, 7th Edition,
Section 1504.3.2.
• Florida Product Approval Rule 61G20-3.
Properties Evaluated:
• Wind Uplift Resistance
• Resistance to Foot Traffic
4. Evaluated Roof System Description:
4.1. Roof Covering: Armour Rib 29 Ga. metal roof
and wall covering panels are cold roll-formed from
minimum 29 gauge ASTM A792 Grade 80 steel sheet.
The panels are aluminum-zinc alloy coated per ASTM
A792 (AZ50), and shall be installed in accordance with
the manufacturer’s instructions and this Certification
Report.
4.2. Roof Deck: Armour Rib Panel metal roof and wall
panels are certified for use over solid or closely-spaced,
nominal 15/32” B-C 4 Ply Plywood sheathing complying
with 2020 Florida Building Code - Building, 7th Edition,
Section 2303.1.5, with or without the use of 1x4 #2 SWP
purlins at 24” O.C., with a minimum slope of 4% (1/2:12).
Lap sealant shall be applied for installed slopes less than
25% (3:12). When used, 1x4 purlins are attached
through the sheathing and into the rafters using (2) 8x3”
deck screws max. 24” O.C.
4.3. Anchorage: Armour Rib 29 Ga. metal roof and
wall panels shall be through-fastened to the purlins or
roof deck using #10-15 x 1-1/2” Woodgrip hex-head
wood screws with bond-seal washer or equivalent, as
specified in Table 1, applied in the patterns described in
Appendix 1.
4.4. Underlayment: Armour Rib 29 Ga. metal roof
panels in new construction applications shall be installed
over underlayment meeting the applicable material type
and attachment details specified in 2020 Florida Building
Code - Building, 7th Edition Table 1507.1.1.1., the
manufacturer’s installation instructions and this
Certification Report.
Metal Roof Certification & Listing Program
Certification Report
11030-002-KCI
Page 2 of 4
Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by
the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or
suitability of a product for a given use.
Installation
Armour Rib 29 Ga. metal roof and wall panels in new
construction applications shall be installed in accordance
with the 2020 Florida Building Code - Building, 7th
Edition, Section 1507.4, the manufacturer’s published
installation instructions and this Certification Report.
Armour Rib 29 Ga. metal roof and wall panels in re-
roofing and re-covering applications may be installed
over a single layer of existing shingles and shall be
installed in accordance with the 2020 Florida Building
Code - Building, 7th Edition, Sections 1507.4 & 1511, the
manufacturer’s published installation instructions and
this Certification Report.
The manufacturer’s installation instructions shall be
made available at the time of installation. If there are
differences between this report and the manufacturer’s
installation instructions, this report shall take
precedence.
5. Product Performance
The performance of the Armour Rib 29 Ga. non-
structural through-fastened metal roof and wall panels
described in this Certification Report has been
determined in accordance with:
• UL 580-94, Tests for Uplift Resistance of Roof
Assemblies.
• UL 1897-98, Uplift Tests for Roof Covering Systems.
• FM 4470, Resistance to Foot Traffic Test.
As tested & reported by the following independent
accredited laboratory:
Note: The UL 580-94 standard is equivalent to the UL
580-06 standard, the UL 1897-04 standard is equivalent
to the UL 1897-2012 standard, and the FM 4470-12
standard is equivalent to the FM 4470-16 standard.
5.1. Wind Resistance
The allowable design uplift pressures for Armour Rib 29
Ga. anchored as described in Table 1 and illustrated in
Appendix 1, when tested in accordance with the
referenced standards with an applied safety factor of 2.0
are found in Table 1.
Table 1
Laboratory Report Ref.
Force Engineering & Testing 384/593-0030T-10A, B
384/593-0030T-10C, D
384/593-0030T-10E
Description
Anchor
Pattern
Anchor
Man’f &
Model
Max
Design
Uplift
Pressure
Over 15/32”
4 Ply
Plywood
A
SFS HiLo
Woodgrip
#10-15 x 1-
1/2”
78.5 psf
Over 15/32”
4 Ply
Plywood
B
SFS HiLo
Woodgrip
#10-15 x 1-
1/2”
108.5 psf
Over 1x4
Purlins Over
15/32” 4 Ply
Plywood
A
SFS HiLo
Woodgrip
#10-15 x 1-
1/2”
108.5 psf
Over 1x4
Purlins Over
15/32” 4 Ply
Plywood
B
SFS HiLo
Woodgrip
#10-15 x 1-
1/2”
183.5 psf
Metal Roof Certification & Listing Program
Certification Report
11030-002-KCI
Page 3 of 4
Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by
the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or
suitability of a product for a given use.
11030-002-KCI
keystonecerts.com
5.2. Resistance to Foot Traffic
The Armour Rib 29 Ga. non-structural through-fastened
metal roof and wall panels were tested per the
referenced standard installed using Anchor Pattern A
over 1x4 SWP purlins over 15/32” 4 ply plywood. The
resultant deflection under load and permanent
deflection were within the allowable limits defined by
the standard.
6. Conditions of Use
Armour Rib 29 Ga. non-structural through-fastened
metal roof and wall panels must be insulated against
other materials or metals including concrete, lead,
copper and treated lumber that contains corrosive
materials.
7. Limitations of Use
Armour Rib 29 Ga. non-structural through-fastened
metal roof and wall panels are not qualified for use in the
High Velocity Hurricane Zone (HVHZ).
Fire classification, shear diaphragm design, roof deck
design & attachment to supporting members are not
within the scope of this Certification Report.
Each licensed facility is subject to periodic inspection by
Keystone Certifications to verify conformance with
Keystone Roof Covering Certification & Listing Program
requirements.
9. Identification
Armour Rib 29 Ga. non-structural through-fastened
metal roof and wall panels represented by this report
shall be identified with Keystone Roof Covering
Certification & Listing Program certification labeling
illustrated below, to be applied to individual panels,
packaging, invoicing or bills of lading:
2021.01.1
Roof support framing shall comply with 2020 Florida
Building Code - Building, 7th Edition, Chapter 22 for steel,
Chapter 23 for wood and Chapter 16 for structural
loading.
8. Licensed Manufacturing Facilities
This Certification Report is applicable only to Armour Rib
29 Ga. non-structural through-fastened metal roof and
wall panels manufactured at the following locations:
Validations Manager
Aaron M. Shultz
Validation Manager
1 09:35:41
-05'00'
1st Coast Metal Roofing Supply
186 State Rd 207
East Palatka, Florida 32131
Metal Roof Certification & Listing Program
Certification Report
11030-002-KCI
Page 4 of 4
Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by
the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or
suitability of a product for a given use.
Appendix 1
Anchor Pattern A
Anchor Pattern B
Note: In all cases (new construction, re-roofing and re-
covering), the anchors shall fully penetrate the purlins
or the plywood roof deck (as applicable).
Metal Roof Certification & Listing Program
Certification Report
11030-002-KCI
Issue Dated: 145 Limekiln Road, Suite 100B 10/27/2017
Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by
the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or
suitability of a product for a given use.
New Cumberland, PA 17070 Revision Date: 1/11/2021
www.keystonecerts.com Expiration Date: 10/12/2025
Certificate Revisions
Rev # Date Description
0 10/27/2017 Initial issuance.
1 1/8/2018 Added reference to associated Florida Product Approval No 24397.
2 1/23/2018 Added hyperlink to FL24397
3 6/25/2018 Removed ref’s to measurements for mat’l thickness and yield strength, relying on
applicable Gauge and steel Grade. Added ref to 1x4 purlin anchorage.
4 03/12/2019 Updated Model name to include metal roof "and wall panels"
5 9/3/2019 Updated ANSI Logo to proper requirements.
6 10/3/2019 Revised anchorage illustrations for clarity, added reference to optional re-roofing
/ re-covering installation over “one layer of existing shingles”.
7 10/12/2020 Updated to 2020 FBC 7th Edition.
8 1/11/2021 Corrected Model name. Updated FPA link.