Loading...
755 Amberjack Ln ROOF23-0070 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: STANFORD RICHARD 755 AMBERJACK LA ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: QUALITY DISCOUNT ROOFING LLC 3481 ST. AUGUSTINE ROAD JACKSONVILLE FL 32207 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 171198 0000 ROYAL PALMS UNIT 01 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 755 AMBERJACK LN ROOF NON SHINGLE Re-Roof Metal $16584.30 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved. All roofing projects require an In- Progress Inspection. Sheathing installation and replacement guidelines per APA. Underlayment must conform to FBC-R Table 905.1.1. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 10/12/2023 PERMIT NUMBER ROOF23-0070 ISSUED: 10/12/2023 EXPIRES: 4/9/2024 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 BUILDING PERMIT 455-0000-322-1000 0 $135.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $67.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.79 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.53 TOTAL: $258.82 2 of 2Issued Date: 10/12/2023 PERMIT NUMBER ROOF23-0070 ISSUED: 10/12/2023 EXPIRES: 4/9/2024 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION Re-Roof Metal 755 AMBERJACK LN QUALITY DISCOUNT ROOFING LLC ROOF23-0070 ROOF23-0070 Metal Roof Certification & Listing Program Certification Report 11030-002-KCI Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or suitability of a product for a given use. Division: 07 00 00 – Thermal & Moisture Protection Section: 07 41 13 – Metal roof and wall panels This Certification Report was used to qualify Florida Product Approval FL 24397-R6. 145 Limekiln Road, Suite 100B Issue Dated: 10/27/2017 New Cumberland, PA 17070 Revision Date: 1/11/2021 www.keystonecerts.com Expiration Date: 10/12/2025 Construction Specifications Institute (CSI) Category: 1. Program Licensee: 1st Coast Metal Roofing Supply 186 SR 207 East Palatka, FL 32131 386-325-0242 http://www.1stcoastmrs.com/ 2. Certified Roof Covering: 1st Coast Metal Roofing Supply’s Model Armour Rib 29 Ga. non-structural through-fastened metal roof and wall panels installed over plywood sheathing roof deck for use in new construction, re-roofing and re-covering applications. 3. Scope of Certification: This Certification Report provides technical data substantiating that the use of the certified roof covering and the evaluated roof systems are in compliance with the following: • 2020 Florida Building Code - Building, 7th Edition, Section 1504.3.2. • Florida Product Approval Rule 61G20-3. Properties Evaluated: • Wind Uplift Resistance • Resistance to Foot Traffic 4. Evaluated Roof System Description: 4.1. Roof Covering: Armour Rib 29 Ga. metal roof and wall covering panels are cold roll-formed from minimum 29 gauge ASTM A792 Grade 80 steel sheet. The panels are aluminum-zinc alloy coated per ASTM A792 (AZ50), and shall be installed in accordance with the manufacturer’s instructions and this Certification Report. 4.2. Roof Deck: Armour Rib Panel metal roof and wall panels are certified for use over solid or closely-spaced, nominal 15/32” B-C 4 Ply Plywood sheathing complying with 2020 Florida Building Code - Building, 7th Edition, Section 2303.1.5, with or without the use of 1x4 #2 SWP purlins at 24” O.C., with a minimum slope of 4% (1/2:12). Lap sealant shall be applied for installed slopes less than 25% (3:12). When used, 1x4 purlins are attached through the sheathing and into the rafters using (2) 8x3” deck screws max. 24” O.C. 4.3. Anchorage: Armour Rib 29 Ga. metal roof and wall panels shall be through-fastened to the purlins or roof deck using #10-15 x 1-1/2” Woodgrip hex-head wood screws with bond-seal washer or equivalent, as specified in Table 1, applied in the patterns described in Appendix 1. 4.4. Underlayment: Armour Rib 29 Ga. metal roof panels in new construction applications shall be installed over underlayment meeting the applicable material type and attachment details specified in 2020 Florida Building Code - Building, 7th Edition Table 1507.1.1.1., the manufacturer’s installation instructions and this Certification Report. Metal Roof Certification & Listing Program Certification Report 11030-002-KCI Page 2 of 4 Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or suitability of a product for a given use. Installation Armour Rib 29 Ga. metal roof and wall panels in new construction applications shall be installed in accordance with the 2020 Florida Building Code - Building, 7th Edition, Section 1507.4, the manufacturer’s published installation instructions and this Certification Report. Armour Rib 29 Ga. metal roof and wall panels in re- roofing and re-covering applications may be installed over a single layer of existing shingles and shall be installed in accordance with the 2020 Florida Building Code - Building, 7th Edition, Sections 1507.4 & 1511, the manufacturer’s published installation instructions and this Certification Report. The manufacturer’s installation instructions shall be made available at the time of installation. If there are differences between this report and the manufacturer’s installation instructions, this report shall take precedence. 5. Product Performance The performance of the Armour Rib 29 Ga. non- structural through-fastened metal roof and wall panels described in this Certification Report has been determined in accordance with: • UL 580-94, Tests for Uplift Resistance of Roof Assemblies. • UL 1897-98, Uplift Tests for Roof Covering Systems. • FM 4470, Resistance to Foot Traffic Test. As tested & reported by the following independent accredited laboratory: Note: The UL 580-94 standard is equivalent to the UL 580-06 standard, the UL 1897-04 standard is equivalent to the UL 1897-2012 standard, and the FM 4470-12 standard is equivalent to the FM 4470-16 standard. 5.1. Wind Resistance The allowable design uplift pressures for Armour Rib 29 Ga. anchored as described in Table 1 and illustrated in Appendix 1, when tested in accordance with the referenced standards with an applied safety factor of 2.0 are found in Table 1. Table 1 Laboratory Report Ref. Force Engineering & Testing 384/593-0030T-10A, B 384/593-0030T-10C, D 384/593-0030T-10E Description Anchor Pattern Anchor Man’f & Model Max Design Uplift Pressure Over 15/32” 4 Ply Plywood A SFS HiLo Woodgrip #10-15 x 1- 1/2” 78.5 psf Over 15/32” 4 Ply Plywood B SFS HiLo Woodgrip #10-15 x 1- 1/2” 108.5 psf Over 1x4 Purlins Over 15/32” 4 Ply Plywood A SFS HiLo Woodgrip #10-15 x 1- 1/2” 108.5 psf Over 1x4 Purlins Over 15/32” 4 Ply Plywood B SFS HiLo Woodgrip #10-15 x 1- 1/2” 183.5 psf Metal Roof Certification & Listing Program Certification Report 11030-002-KCI Page 3 of 4 Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or suitability of a product for a given use. 11030-002-KCI keystonecerts.com 5.2. Resistance to Foot Traffic The Armour Rib 29 Ga. non-structural through-fastened metal roof and wall panels were tested per the referenced standard installed using Anchor Pattern A over 1x4 SWP purlins over 15/32” 4 ply plywood. The resultant deflection under load and permanent deflection were within the allowable limits defined by the standard. 6. Conditions of Use Armour Rib 29 Ga. non-structural through-fastened metal roof and wall panels must be insulated against other materials or metals including concrete, lead, copper and treated lumber that contains corrosive materials. 7. Limitations of Use Armour Rib 29 Ga. non-structural through-fastened metal roof and wall panels are not qualified for use in the High Velocity Hurricane Zone (HVHZ). Fire classification, shear diaphragm design, roof deck design & attachment to supporting members are not within the scope of this Certification Report. Each licensed facility is subject to periodic inspection by Keystone Certifications to verify conformance with Keystone Roof Covering Certification & Listing Program requirements. 9. Identification Armour Rib 29 Ga. non-structural through-fastened metal roof and wall panels represented by this report shall be identified with Keystone Roof Covering Certification & Listing Program certification labeling illustrated below, to be applied to individual panels, packaging, invoicing or bills of lading: 2021.01.1 Roof support framing shall comply with 2020 Florida Building Code - Building, 7th Edition, Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading. 8. Licensed Manufacturing Facilities This Certification Report is applicable only to Armour Rib 29 Ga. non-structural through-fastened metal roof and wall panels manufactured at the following locations: Validations Manager Aaron M. Shultz Validation Manager 1 09:35:41 -05'00' 1st Coast Metal Roofing Supply 186 State Rd 207 East Palatka, Florida 32131 Metal Roof Certification & Listing Program Certification Report 11030-002-KCI Page 4 of 4 Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or suitability of a product for a given use. Appendix 1 Anchor Pattern A Anchor Pattern B Note: In all cases (new construction, re-roofing and re- covering), the anchors shall fully penetrate the purlins or the plywood roof deck (as applicable). Metal Roof Certification & Listing Program Certification Report 11030-002-KCI Issue Dated: 145 Limekiln Road, Suite 100B 10/27/2017 Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or suitability of a product for a given use. New Cumberland, PA 17070 Revision Date: 1/11/2021 www.keystonecerts.com Expiration Date: 10/12/2025 Certificate Revisions Rev # Date Description 0 10/27/2017 Initial issuance. 1 1/8/2018 Added reference to associated Florida Product Approval No 24397. 2 1/23/2018 Added hyperlink to FL24397 3 6/25/2018 Removed ref’s to measurements for mat’l thickness and yield strength, relying on applicable Gauge and steel Grade. Added ref to 1x4 purlin anchorage. 4 03/12/2019 Updated Model name to include metal roof "and wall panels" 5 9/3/2019 Updated ANSI Logo to proper requirements. 6 10/3/2019 Revised anchorage illustrations for clarity, added reference to optional re-roofing / re-covering installation over “one layer of existing shingles”. 7 10/12/2020 Updated to 2020 FBC 7th Edition. 8 1/11/2021 Corrected Model name. Updated FPA link.