Loading...
371 Plaza ROOF23-0071 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: MURCHISON LINDA L 371 PLAZA RD ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: PIMENTEL ROOFING INC 402 St. Augustine Blvd.JACKSONVILLE BEACH FL 32250 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 170016 0000 ATLANTIC BEACH JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 371 PLAZA ROOF NON SHINGLE SHINGLE AND MODIFIED ROOF $20800.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved. All roofing projects require an In- Progress Inspection. Sheathing installation and replacement guidelines per APA. Underlayment must conform to FBC-R Table 905.1.1. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 10/16/2023 PERMIT NUMBER ROOF23-0071 ISSUED: 10/16/2023 EXPIRES: 4/13/2024 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 BUILDING PERMIT 455-0000-322-1000 0 $155.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $77.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.49 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.33 TOTAL: $238.32 2 of 2Issued Date: 10/16/2023 PERMIT NUMBER ROOF23-0071 ISSUED: 10/16/2023 EXPIRES: 4/13/2024 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION SHINGLE AND MODIFIED ROOF 371 PLAZA PIMENTEL ROOFING INC ROOF23-0071 ROOF23-0071 ROOF23-0071 ROOF23-0071 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 Christian Street Oxford, CT 06478 (203) 262-9245 EVALUATION REPORT Tremco Incorporated 3735 Green Road Beachwood, OH 44122 (800) 562-2728 Evaluation Report T43130.12.12-R2 FL16129-R2 Date of Issuance: 12/20/2012 Revision 2: 09/19/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Vulkem® Waterproofing Systems LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. ADVERTISEMENT: The Evaluation Report number preceded by the words “Trinity|ERD Evaluated” may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 3, plus a 1-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facimilie seal appearing was authorized by Robert Nieminen, P.E. on 09/19/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity|ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity|ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing produ cts for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ROOF23-0071 Exterior Research and Design, LLC. Evaluation Report T43130.12.12-R2 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL16129-R2 Vulkem® Waterproofing Systems Revision 2: 09/19/2017 Page 2 of 3 ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Waterproofing Compliance Statement: Vulkem® Waterproofing Systems, as produced by Tremco Incorporated, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2011 1507.15.2 Physical Properties ASTM C836 2012 1507.15.2 Physical Properties ASTM C957 2010 3. REFERENCES: Entity Examination Reference Date PRI (TST5878) Physical Properties TRE-042-02-01 02/07/2011 PRI (TST5878) Physical Properties TRE-043-02-01 02/07/2011 PRI (TST5878) Physical Properties TRE-044-02-01 03/25/2011 PRI (TST5878) Wind Uplift TRE-041-02-01 12/22/2011 UL, LLC. (QUA9625) Quality Control Service Confirmation Exp. 03/27/2020 4. PRODUCT DESCRIPTION: This Evaluation Report covers Vulkem® Waterproofing Systems applied to Approved substrates as outlined in the Limitations / Conditions of Use herein. The following Tremco products make up the subject systems. 4.1 Vulkem® Primer #171: One-part, film-forming primer for porous surfaces. 4.2 Vulkem® Primer #191: One part, interlaminar primer. 4.3 Vulkem® 350NF-R: One part, Roller-grade polyurethane base coat. 4.4 Vulkem® 350NF-S/L: One-part, Self-Leveling polyurethane base coat. 4.5 Vulkem® 351: One-part, aliphatic polyurethane top coat. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Refer to a current Roofing Materials Directory for fire ratings of this product. 5.4 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.5 The maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems 5.6 In a re-roof (tear off) installation, the existing deck shall be examined for compatibility with the waterproofing system to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new waterproofing assembly. Exterior Research and Design, LLC. Evaluation Report T43130.12.12-R2 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL16129-R2 Vulkem® Waterproofing Systems Revision 2: 09/19/2017 Page 3 of 3 5.7 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3).. 5.8 The Authority Having Jurisdiction may require integrity flood testing (ASTM D5957) or Electric Leak Detection tests of all waterproofing systems prior to placement of the overburden material. Testing should be conducted by a qualified design professional. 5.9 All products in the waterproof assembly shall have quality assurance in accordance with FAC Rule 61G20-3. 5.9.1 This evaluation pertains to the Tremco components making up the waterproofing assembly, and performance when used in conjunction with non-Tremco components, as outlined in Appendix 1. This evaluation does not purport to address QA for non-Tremco components within the waterproofing assemblies, such as overburden products. 6. INSTALLATION: 6.1 Vulkem® Waterproofing Systems shall be installed in accordance with Tremco Incorporated current, published installation instructions, subject to the Limit ations / Conditions of Use noted herein. Flashing and detailing shall be in accordance with Tremco published installation instructions using Tremco specified materials to establish a watertight condition. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. ”MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads , and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for information on plants covered under F.A.C. Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: UL, LLC. – QUA9625; (631) 546-2458; Kanchi.Agrawala-Dokania@ul.com - THE ONE (1) PAGE THAT FOLLOWS FORMS PART OF THIS EVALUATION REPORT - Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report T43130.12.12-R2 for FL16129-R2 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/19/2017 Prepared by: Robert Nieminen, PE-59166 Vulkem® Waterproofing Systems; (800) 562-2728 Appendix 1, Page 1 of 1 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE The following notes apply to the systems outlined herein: 1. The evaluation herein pertains to above-deck waterproofing components. Decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the deck shall be documented through proper codified and/or FBC Approval documentation. 2. The maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 3. For existing substrates in a re-roof installation, the existing roof deck shall be examined for compatibility and bond performance with the waterproofing mem brane to the satisfaction of the Authority Having Jurisdiction. The Authority Having Jurisdiction may require field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 4. ”MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. 5. If Vulkem 350NF-R or 350NF-S/L has cured greater than 24 hours or the surface becomes contaminated, clean and prime with Vulkem #191 primer in accordance wi th Tremco Incorporated published requirements prior to applying subsequent coats. 6. The seeding and back-rolling of aggregate shall be in accordance with Tremco Incorporated published requirements, with an even broadcast to refusal. Any loose aggregate should be removed prior to recoating. TABLE 1: CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED WATERPROOFING COVER System No. Deck (See Note 1) Waterproofing Overburden MDP (psf) Primer Base Coat Top Coat C-1. Structural Concrete (Optional) Vulkem Primer #171 Vulkem 350NF-R (60 wet mils) Vulkem 350NF-R (10 wet mils) Aggregate: 20-40 mesh silica sand Ceramic plaza deck tiles (12 x 12 x ¼-inch) fully embedded into Increate Systems Thin- Crete Grout using a ¼-inch notched trowel. -597.5 C-2. Structural Concrete (Optional) Vulkem Primer #171 Vulkem 350NF-S/L (60 wet mils) Vulkem 350NF-S/L (10 wet mils) Aggregate: 20-40 mesh silica sand Ceramic plaza deck tiles (12 x 12 x ¼-inch) fully embedded into Increate Systems Thin- Crete Grout using a ¼-inch notched trowel. -620.0 C-3. Structural Concrete (Optional) Vulkem Primer #171 Vulkem 350NF-R or 350NF-S/L (40 wet mils) Vulkem 351 (15 wet mils) Aggregate: 40-50 mesh silica sand or aluminum oxide None -815.0 ROOF23-0071