Young Energy Calcs, Young Residence, 826 Ocean Blvd, Atl BchFORM R405-2022 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2022 Florida Building Code, Energy Conservation via the Residential Simulated Performance Alternative shall include: This checklist Form R405-2022 report Input summary checklist that can be used for field verification (usually four pages/may be greater) Energy Performance Level (EPL) Display Card (one page) HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 Mandatory Requirements (five pages) Required prior to CO: Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 - one page) A completed 2022 Envelope Leakage Test Report (usually one page); exception in R402.4 allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to comply with Section C402.5 If Form R405 duct leakage type indicates anything other than "default leakage", then a completed 2020 Duct Leakage Test Report - Performance Method (usually one page) . 4/21/2023 1:49:48 PM Page 1 of 1 FORM R405-2022 Supplement FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name:Young Residence Builder Name:Aurora Builders, Inc. Street:826 Ocean Blvd Permit Office:Atlantic Beach City, State, Zip:Atlantic Beach, FL, Permit Number: Owner:Jurisdiction:261100 Design Location:FL, MAYPORT_NS County:Duval(Florida Climate Zone 2) 1. New construction or existing New (From Plans) 2. Single family or multiple family Detached 3. Number of units, if multiple family 1 4. Number of Bedrooms 4 5. Is this a worst case?No 6. Conditioned floor area above grade (ft²)4753 Conditioned floor area below grade (ft²)0 7. Windows(1172.6 sqft.)Description Area a. U-Factor:Dbl, U=0.29 673.40 ft2 SHGC:SHGC=0.18 b. U-Factor:Dbl, U=0.30 372.00 ft2 SHGC:SHGC=0.25 c. U-Factor:Dbl, U=0.27 93.50 ft2 SHGC:SHGC=0.22 Area Weighted Average Overhang Depth:4.947 ft Area Weighted Average SHGC:0.205 8. Skylights Description Area U-Factor:(AVG)N/A N/A ft2 SHGC(AVG):N/A 9. Floor Types Insulation Area a. Slab-On-Grade Edge Insulation R= 0.0 2233.00 ft2 b. Floor Over Other Space R= 0.0 1750.00 ft2 c. other (see details)R= 770.00 ft2 10. Wall Types(7201.0 sqft.) Insulation Area a. Frame - Wood, Exterior R=19.0 6921.20 ft2 b. Frame - Wood, Adjacent R=13.0 279.77 ft2 c. N/A d. N/A 11. Ceiling Types(3003.0 sqft.) Insulation Area a. Roof Deck (Unvented)R=20.0 3003.00 ft2 b. N/A c. N/A 12. Roof(Comp. Shingles, Unvent)Deck R=20.0 3609 ft2 13. Ducts, location & insulation level R ft2 a. Sup: 1st Floor, Ret: 1st Floor, AH: 1st Floor 6 178 b. Sup: Attic, Ret: Attic, AH: 2nd Floor 6 281 c. 1 additional duct system(s)(see details) 14. Cooling Systems kBtu/hr Efficiency a. Central Unit 23.2 SEER2:15.20 b. Central Unit 29.2 SEER2:15.20 c. Central Unit 23.2 SEER2:15.20 15. Heating Systems kBtu/hr Efficiency a. Electric Heat Pump 22.6 HSPF2:7.80 b. Electric Heat Pump 27.4 HSPF2:8.10 c. Electric Heat Pump 22.6 HSPF2:7.80 16. Hot Water Systems a. PropaneTankless Cap: 1 gallons EF: 0.780 b. Conservation features None 17. Credits Pstat Glass/Floor Area:0.247 Total Proposed Modified Loads:117.57 Total Baseline Loads:143.52 PASS I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code.calculation indicates compliance with the Florida Energy Code. PREPARED BY: _________________________________Before construction is completed this building will be inspected for DATE: _________________________________________compliance with Section 553.908 Florida Statutes. I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: __________________________________BUILDING OFFICIAL: ____________________________ DATE: _________________________________________DATE: _________________________________________ - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Default duct leakage does not require a Duct Leakage Test Report. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 4/21/2023 1:49:48 PM EnergyGauge® USA 7.5.00 - FlaRes2020 FBC 7th Edition (2022 Supplement) Compliant Software Page 1 4/21/2023 FORM R405-2022S INPUT SUMMARY CHECKLIST REPORT PROJECT Title:Young Residence Address type:Street Address Building Type:Bedrooms:Lot #:User 4 --- Owner:Conditioned Area:Block/SubDivision:4753 --- Builder Home ID:Total Stories:PlatBook:2 --- Builder Name:Worst Case:Street:Aurora Builders, Inc.No 826 Ocean Blvd Permit Office:Rotate Angle:County:Atlantic Beach 0 Duval Jurisdiction:Cross Ventilation:City, State, Zip:261100 Atlantic Beach, Family Type:Whole House Fan: Detached FL, New/Existing:Terrain: New (From Plans)Suburban Year Construct:Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily temp Location Tmy Site 97.5%2.5%Winter Summer Degree Days Moisture Range ___ FL, MAYPORT_NS FL_MAYPORT_NS 39 90 70 75 1037 61 Medium BLOCKS Number Name Area Volume ___ 1 Block1 1368 13817 cu ft ___ 2 Block2 2158 23089 cu ft ___ 3 Block3 1227 13620 cu ft SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated ___ 1 1st Floor Front 1368 13817 Yes 0 0 Yes Yes Yes ___ 2 1st Floor Rear 865 8737 No 2 1 Yes Yes Yes ___ 3 2nd Floor Front 1227 13620 No 2 2 Yes Yes Yes ___ 4 2nd Floor Rear 1293 14352 No 1 1 Yes Yes Yes FLOORS (Total Exposed Area = 3003 sq.ft.) #Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet ___ 1 Slab-On-Grade Edge Ins 1st Floor Front 200.5 0 1368 ft 0.304 ---0.00 0.00 1.00 ___ 2 Slab-On-Grade Edge Ins 1st Floor Rear 119.9 0 865 ft 0.304 ---0.00 0.00 1.00 ___ 3 Raised Floor 2nd Floor Front ------109 ft 0.053 19 0.00 0.00 1.00 ___ 4 Raised Floor 2nd Floor Rear ------49 ft 0.053 19 0.00 0.00 1.00 ___ 5 Floor over Garage 2nd Floor Rear ------612 ft 0.051 19 0.00 0.00 1.00 ___ 6 Floor Over Other Space 2nd Floor Front ------1118 ft 0.172 0.00 0.00 1.00 ___ 7 Floor Over Other Space 2nd Floor Rear ------632 ft 0.172 0.00 0.00 1.00 ROOF Roof Gable Roof SolarRad SA Emitt Emitt Deck Pitch #Type Materials Area Area Color Absor.Barr Tested Tested Insul.(deg) ___ 1 Hip Composition shingles 3609 ft²0 ft²Medium N 0.6 No 0.3 No 20 33.69 4/21/2023 1:49:48 PM Page 2EnergyGauge® USA 7.5.00 - FlaRes2020 FBC 7th Edition (2022 Supplement) Compliant Software FORM R405-2022S INPUT SUMMARY CHECKLIST REPORT ATTIC #Type Ventilation Vent Ratio (1 in)Area RBS IRCC ___ 1 Full attic Unvented 0 3003 ft²N N CEILING (Total Exposed Area = 3003 sq.ft.) #Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac.Truss Type ___ 1 Flat ceiling under attic(Unvented)1st Floor Front 0.0 Blown 250.0ft²0.059 0.05 Wood ___ 2 Flat ceiling under attic(Unvented)1st Floor Rear 0.0 Blown 233.0ft²0.059 0.05 Wood ___ 3 Flat ceiling under attic(Unvented)2nd Floor Front 0.0 Blown 1227.0ft²0.059 0.05 Wood ___ 4 Flat ceiling under attic(Unvented)2nd Floor Rear 0.0 Blown 1293.0ft²0.059 0.05 Wood WALLS (Total Exposed Area = 7201 sq.ft.) Adjacent Cavity Width Height Area U-Sheath Frm.Solar Below #Ornt To Wall Type Space R-Value Ft In Ft In sq.ft.Factor R-Value Frac.Absor.Grade ___ 1 E Exterior Frame - Wood 1st Floor Front 19.0 14.2 0 10.1 0 143.4 0.071 0.23 0.60 0 % ___ 2 E Exterior Frame - Wood 1st Floor Front 19.0 22.2 0 10.1 0 224.2 0.071 0.23 0.60 0 % ___ 3 N Exterior Frame - Wood 1st Floor Front 19.0 66.6 0 10.1 0 672.7 0.071 0.23 0.60 0 % ___ 4 W Exterior Frame - Wood 1st Floor Front 19.0 5.2 0 10.1 0 52.5 0.071 0.23 0.60 0 % ___ 5 N Exterior Frame - Wood 1st Floor Rear 19.0 33.7 0 10.1 0 340.4 0.071 0.23 0.60 0 % ___ 6 W Exterior Frame - Wood 1st Floor Rear 19.0 5.0 0 10.1 0 50.5 0.071 0.23 0.60 0 % ___ 7 W Garage Frame - Wood 1st Floor Rear 13.0 24.7 0 10.1 0 249.5 0.094 0.23 0.60 0 % ___ 8 S Garage Frame - Wood 1st Floor Rear 13.0 3.0 0 10.1 0 30.3 0.094 0.23 0.60 0 % ___ 9 S Exterior Frame - Wood 1st Floor Rear 19.0 30.0 0 10.1 0 303.0 0.071 0.23 0.60 0 % ___ 10 E Exterior Frame - Wood 1st Floor Rear 19.0 23.5 0 10.1 0 237.4 0.071 0.23 0.60 0 % ___ 11 S Exterior Frame - Wood 1st Floor Front 19.0 67.7 0 10.1 0 683.8 0.071 0.23 0.60 0 % ___ 12 W Exterior Frame - Wood 1st Floor Front 19.0 24.6 0 10.1 0 248.5 0.071 0.23 0.60 0 % ___ 13 E Exterior Frame - Wood 2nd Floor Front 19.0 34.3 0 11.1 0 380.7 0.071 0.23 0.60 0 % ___ 14 N Exterior Frame - Wood 2nd Floor Front 19.0 57.5 0 11.1 0 638.3 0.071 0.23 0.60 0 % ___ 15 N Exterior Frame - Wood 2nd Floor Rear 19.0 57.5 0 11.1 0 638.3 0.071 0.23 0.60 0 % ___ 16 W Exterior Frame - Wood 2nd Floor Rear 19.0 29.7 0 11.1 0 329.7 0.071 0.23 0.60 0 % ___ 17 S Exterior Frame - Wood 2nd Floor Rear 19.0 46.3 0 11.1 0 513.9 0.071 0.23 0.60 0 % ___ 18 E Exterior Frame - Wood 2nd Floor Rear 19.0 8.5 0 11.1 0 94.4 0.071 0.23 0.60 0 % ___ 19 S Exterior Frame - Wood 2nd Floor Rear 19.0 10.5 0 11.1 0 116.6 0.071 0.23 0.60 0 % ___ 20 E Exterior Frame - Wood 2nd Floor Rear 19.0 21.2 0 11.1 0 235.3 0.071 0.23 0.60 0 % ___ 21 S Exterior Frame - Wood 2nd Floor Front 19.0 47.1 0 11.1 0 522.8 0.071 0.23 0.60 0 % ___ 22 S Exterior Frame - Wood 2nd Floor Front 19.0 10.7 0 11.1 0 118.8 0.071 0.23 0.60 0 % ___ 23 W Exterior Frame - Wood 2nd Floor Front 19.0 33.9 0 11.1 0 376.3 0.071 0.23 0.60 0 % DOORS (Total Exposed Area = 43 sq.ft.) Width Height #Ornt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area ___ 1 W Wood 1st Floor Rear None 0.46 2.70 0 8.00 0 21.6ft² ___ 2 S Wood 1st Floor Rear None 0.46 2.70 0 8.00 0 21.6ft² 4/21/2023 1:49:48 PM Page 3EnergyGauge® USA 7.5.00 - FlaRes2020 FBC 7th Edition (2022 Supplement) Compliant Software FORM R405-2022S INPUT SUMMARY CHECKLIST REPORT WINDOWS (Total Exposed Area = 1173 sq.ft.) Wall Total Same Width Height --Overhang-- #Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Units (ft)(ft)Depth Sep.Interior Shade Screen (ft²)(ft)(ft) ___ 1 E 1 Wood Low-E Double Y 0.29 0.18 N N 37.8 2 2.70 7.00 6.0 1.0 None None ___ 2 E 1 Wood Low-E Double Y 0.30 0.25 N N 24.0 1 3.00 8.00 6.0 1.0 None None ___ 3 E 2 Wood Low-E Double Y 0.29 0.18 N N 40.5 3 2.70 5.00 1.0 13.5 None None ___ 4 N 3 Wood Low-E Double Y 0.29 0.18 N N 81.0 6 2.70 5.00 1.0 13.5 None None ___ 5 N 3 Wood Low-E Double Y 0.27 0.22 N N 6.0 1 3.00 2.00 1.0 13.5 None None ___ 6 N 5 Wood Low-E Double Y 0.29 0.18 N N 27.0 2 2.70 5.00 1.0 13.5 None None ___ 7 W 6 Wood Low-E Double Y 0.29 0.18 N N 13.5 1 2.70 5.00 1.0 13.5 None None ___ 8 S 9 Wood Low-E Double Y 0.27 0.22 N N 6.0 1 3.00 2.00 1.0 13.5 None None ___ 9 E 10 Wood Low-E Double Y 0.25 0.24 N N 6.8 3 1.50 1.50 1.0 13.5 None None ___ 10E 10 Wood Low-E Double Y 0.29 0.18 N N 48.6 3 2.70 6.00 1.0 13.5 None None ___ 11S 11 Wood Low-E Double Y 0.30 0.25 N N 48.0 2 3.00 8.00 1.0 13.5 None None ___ 12S 11 Wood Low-E Double Y 0.29 0.18 N N 48.6 3 2.70 6.00 1.0 13.5 None None ___ 13W 12 Wood Low-E Double Y 0.30 0.25 N N 144.0 6 3.00 8.00 11.0 1.0 None None ___ 14S 11 Wood Low-E Double Y 0.29 0.18 N N 48.6 3 2.70 6.00 1.0 13.5 None None ___ 15E 13 Wood Low-E Double Y 0.30 0.16 N N 27.0 2 2.70 5.00 1.0 1.0 None None ___ 16E 13 Wood Low-E Double Y 0.30 0.25 N N 43.2 2 2.70 8.00 1.0 1.0 None None ___ 17N 14 Wood Low-E Double Y 0.29 0.18 N N 10.0 1 2.00 5.00 1.0 1.0 None None ___ 18N 14 Wood Low-E Double Y 0.27 0.22 N N 40.5 3 2.70 5.00 1.0 1.0 None None ___ 19N 15 Wood Low-E Double Y 0.29 0.18 N N 67.5 5 2.70 5.00 1.0 1.0 None None ___ 20N 15 Wood Low-E Double Y 0.27 0.22 N N 14.0 2 3.50 2.00 1.0 1.0 None None ___ 21W 16 Wood Low-E Double Y 0.29 0.18 N N 48.6 3 2.70 6.00 1.0 1.0 None None ___ 22S 17 Wood Low-E Double Y 0.29 0.18 N N 67.5 5 2.70 5.00 1.0 1.0 None None ___ 23E 18 Wood Low-E Double Y 0.30 0.25 N N 21.6 1 2.70 8.00 12.5 1.0 None None ___ 24S 19 Wood Low-E Double Y 0.30 0.25 N N 21.6 1 2.70 8.00 9.7 1.0 None None ___ 25E 20 Wood Low-E Double Y 0.29 0.18 N N 48.6 3 2.70 6.00 1.0 1.0 None None ___ 26S 21 Wood Low-E Double Y 0.27 0.22 N N 27.0 2 2.70 5.00 6.4 1.0 None None ___ 27W 23 Wood Low-E Double Y 0.30 0.25 N N 21.6 1 2.70 8.00 21.0 1.0 None None ___ 28S 22 Wood Low-E Double Y 0.30 0.25 N N 48.0 2 3.00 8.00 23.0 1.0 None None ___ 29W 23 Wood Low-E Double Y 0.29 0.18 N N 75.6 4 2.70 7.00 11.7 1.0 None None ___ 30S 21 Wood Low-E Double Y 0.29 0.18 N N 10.0 1 2.00 5.00 1.0 1.0 None None INFILTRATION #Scope Method SLA CFM50 ELA EqLA ACH ACH50 Space(s)Infiltration Test Volume ___ 1 Wholehouse Proposed ACH(50)0.00034 4210 231.00 433.67 0.1563 5.0 50525 cu ftAll GARAGE #Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation ___ 1 612 ft²612 ft²73 ft 10 ft 1 MASS #Mass Type Area Thickness Furniture Fraction Space ___ 1 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 1st Floor Front ___ 2 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 1st Floor Rear ___ 3 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 2nd Floor Front ___ 4 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 2nd Floor Rear 4/21/2023 1:49:48 PM Page 4EnergyGauge® USA 7.5.00 - FlaRes2020 FBC 7th Edition (2022 Supplement) Compliant Software FORM R405-2022S INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM #System Type Subtype/Speed AHRI #Efficiency Capacity ----Geothermal HeatPump----Ducts Block kBtu/hr Entry Power Volt Current ___ 1 Electric Heat Pump None/Single HSPF2: 7.80 22.6 0.00 0.00 0.00 sys#1 1 ___ 2 Electric Heat Pump None/Single HSPF2: 8.10 27.4 0.00 0.00 0.00 sys#2 2 ___ 3 Electric Heat Pump None/Single HSPF2: 7.80 22.6 0.00 0.00 0.00 sys#3 3 COOLING SYSTEM #System Type Subtype/Speed AHRI #Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm ___ 1 Central Unit None/Single SEER2:15.2 23.2 696 0.75 sys#1 1 ___ 2 Central Unit None/Single SEER2:15.2 29.2 876 0.75 sys#2 2 ___ 3 Central Unit None/Single SEER2:15.2 23.2 696 0.75 sys#3 3 HOT WATER SYSTEM #System Type Subtype Location EF(UEF)Cap Use SetPnt Fixture Flow Pipe Ins.Pipe length ___ 1 Propane Tankless Garage 0.78 (0.78)1.00 gal 70 gal 120 deg Standard None 99 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff ___ 1 No NA NA NA No NA NA NA None DUCTS Duct ---------Supply------------------Return---------Air CFM 25 CFM 25 HVAC # #Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool ___ 1 1st Floor Fro 6.0 178 ft²1st Floor Fro 6.0 68 ft²Default Leakage 1st Floor (Default)(Default)1 1 ___ 2 Attic 6.0 281 ft²Attic 6.0 108 ft²Default Leakage 2nd Floor (Default)(Default)2 2 ___ 3 Attic 6.0 160 ft²Attic 6.0 61 ft²Default Leakage 2nd Floor (Default)(Default)3 3 TEMPERATURES Programable Thermostat: Y Ceiling Fans: N Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec Venting [ ] Jan [ ] Feb [X] Mar [X] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 ___ Cooling (WD)AM 78 78 78 78 78 78 78 78 80 80 80 80PM808080807878787878787878 ___ Cooling (WEH)AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 ___ Heating (WD)AM 65 65 65 65 65 65 65 68 68 68 68 68PM686868686868686868686868 ___ Heating (WEH)AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 4/21/2023 1:49:48 PM EnergyGauge® USA 7.5.00 - FlaRes2020 FBC 7th Edition (2022 Supplement) Compliant Software Page 5 FORM R405-2022 Supplement ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 82 The lower the EnergyPerformance Index, the more efficient the home. 826 Ocean Blvd,Atlantic Beach,FL, 1. New construction or existing New (From Plans) 2. Single family or multiple family Detached 3. Number of units, if multiple family 1 4. Number of Bedrooms 4 5. Is this a worst case?No 6. Conditioned floor area above grade (ft²)4753 Conditioned floor area below grade (ft²)0 7. Windows**Description Area a. U-Factor:Dbl, U=0.29 673.40 ft2 SHGC:SHGC=0.18 b. U-Factor:Dbl, U=0.30 372.00 ft2 SHGC:SHGC=0.25 c. U-Factor:Dbl, U=0.27 93.50 ft2 SHGC:SHGC=0.22 Area Weighted Average Overhang Depth:4.947 ft Area Weighted Average SHGC:0.205 8. Skylights Description Area U-Factor:(AVG)N/A N/A ft2 SHGC(AVG):N/A 9. Floor Types Insulation Area a. Slab-On-Grade Edge Insulation R= 0.0 2233.00 ft2 b. Floor Over Other Space R= 0.0 1750.00 ft2 c. other (see details)R= 770.00 ft2 10. Wall Types(7201.0 sqft.) Insulation Area a. Frame - Wood, Exterior R=19.0 6921.20 ft2 b. Frame - Wood, Adjacent R=13.0 279.77 ft2 c. N/A d. N/A 11. Ceiling Types(3003.0 sqft.) Insulation Area a. Roof Deck (Unvented)R=20.0 3003.00 ft2 b. N/A c. N/A 12. Roof(Comp. Shingles, Unvent)Deck R=20.0 3609 ft2 13. Ducts, location & insulation level R ft2 a. Sup: 1st Floor, Ret: 1st Floor, AH: 1st Floor 6 178 b. Sup: Attic, Ret: Attic, AH: 2nd Floor 6 281 c. 1 additional duct system(s)(see details) 14. Cooling Systems kBtu/hr Efficiency a. Central Unit 23.2 SEER2:15.20 b. Central Unit 29.2 SEER2:15.20 c. Central Unit 23.2 SEER2:15.20 15. Heating Systems kBtu/hr Efficiency a. Electric Heat Pump 22.6 HSPF2:7.80 b. Electric Heat Pump 27.4 HSPF2:8.10 c. Electric Heat Pump 22.6 HSPF2:7.80 16. Hot Water Systems a. PropaneTankless Cap: 1 gallons EF: 0.780 b. Conservation features None 17. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: ___________________________________Date: _________________________ Address of New Home: 826 Ocean Blvd City/FL Zip: Atlantic Beach,FL, *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/21/2023 1:49:48 PM EnergyGauge® USA 7.5.00 - FlaRes2020 FBC 7th Edition (2022 Supplement) Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 7th Edition (2020) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS:826 Ocean Blvd Permit Number: Atlantic Beach, FL MANDATORY REQUIREMENTS - See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card - (Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. SECTION R402 BUILDING THERMAL ENVELOPE R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer’s instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors, and outdoor combustion air. Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight-fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows, skylights and doors. R402.4.4 Rooms containing fuel - burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. 4/21/2023 1:49:48 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 MANDATORY REQUIREMENTS (Continued) R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 L/s) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing (Mandatory). All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be “substantially leak free” in accordance with Section R403.3.3. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer’s designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough-in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer’s air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2 Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer’s air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions; 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. Duct leakage testing is required for Section R405 compliance where credit is taken for leakage, and a duct air leakage Qn to the outside of less than 0.080 (where Qn = duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals) is indicated in the compliance report for the proposed design. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C) or below 55°F (13°C) shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). If heated water circulation systems are installed, they shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 4/21/2023 1:49:48 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 MANDATORY REQUIREMENTS (Continued) R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 ½ inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140°F (38°C to 60°C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water-heating systems to be turned off. R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where an air handler that is integral to tested and listed HVAC equipment is used to provide whole-house mechanical ventilation, the air handler shall be powered by an electronically commutated motor. R403.6.2 Ventilation Air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment. R403.7.1 Equipment sizing (Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. 4/21/2023 1:49:48 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 MANDATORY REQUIREMENTS (Continued) TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACYa AIRFLOW RATE MAXIMUM (CFM)(CFM/WATT)(CFM) HRV or ERV Any 1.2 cfm/watt Any Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt <90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm = 28.3 L/min.a. When tested in accordance with HVI Standard 916 R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section R403.7, or the closest available size provided by the manufacturer’s product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating-test value and shall not be used for equipment sizing. Manufacturer’s expanded performance data shall be used to select cooling-only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water-source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. Attached single- and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer, in attached single- and multiple-family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Florida Building Code, Energy Conservation—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls (Mandatory). Snow- and ice-melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C). 403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas-fired heaters shall not be equipped with continuously burning ignition pilots. 4/21/2023 1:49:48 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 MANDATORY REQUIREMENTS (Continued) R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste-heat-recovery pool heating systems 3. Where pumps are powered exclusively from on-site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception:Where more than 70 percent of the energy for heating, computed over an operation season, is from site-recovered energy, such as from a heat pump or solar energy source, covers or other vapor-retardant means shall not be required R403.10.4 Gas- and oil-fired pool and spa heaters. All gas- and oil-fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions-Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas (Mandatory). The energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14 R403.13 Dehumidifiers (Mandatory). If installed, a dehumidifier shall conform to the following requirements: 1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/ kWh if the total dehumidifier capacity for the house is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day. 2. The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air. 3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2. 4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code, Residential. R403.13.1 Ducted dehumidifiers. Ducted dehumidifiers shall, in addition to conforming to the requirements of Section R403.13, conform to the following requirements: 1. If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system, a backdraft damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct. 2. If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system, a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct. 3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the central cooling evaporator coil. 4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment (Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an efficacy of at least 45 lumens-per-watt or shall utilize lamps with an efficacy of not less than 65 lumens-per-watt. R404.1.1 Lighting equipment (Mandatory). uel gas lighting systems shall not have continuously burning pilot lights. 4/21/2023 1:49:48 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 CHECK2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa Project Name:Young Residence Builder Name:Aurora Builders, Inc. Street:826 Ocean Blvd Permit Office:Atlantic Beach City, State, Zip:Atlantic Beach, FL, Permit Number: Owner:Jurisdiction:261100 Design Location:FL, MAYPORT_NS County:Duval(Florida Climate Zone 2) COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope.Air-permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier.not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed.shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed.Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed.a material having a thermal resistance of R-3 per Knee walls shall be sealed.inch minimum Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier.Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation.maintain permanent contact with the underside of above-garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors)of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation with a Class I vapor retarder with overlapping joints taped.shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface.thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall on exterior wall and tubs shall separate them from the showers and tubs.be insulated. Electrical/phone box The air barrier shall be installed behind electrical or on exterior walls communication boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 4/21/2023 1:49:48 PM EnergyGauge® USA 7.0 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2020 Florida Building Code, Energy Conservation, 7th Edition Jurisdiction:261100 Permit #: Job Information Builder:Aurora Builders, Inc.Community:Lot:NA Address:826 Ocean Blvd City:Atlantic Beach State:FL Zip: Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 and 2. PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on Form R405-2020 (Performance) or R406-2020 (ERI), section labeled as infiltration, sub-section ACH50. ACH(50) specified on Form R405-2020-Energy Calc (Performance) or R406-2020 (ERI):5.000 _________ x 60 ÷ ______________ = ____________50525 CFM(50) Building Volume ACH(50) PASS When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. Method for calculating building volume:_____________________________ Retrieved from architectural plans Code software calculated Field measured and calculated R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: ______________________________________Phone: ________________________ I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: ____________________________________Date of Test: ______________________ Printed Name of Tester: _________________________________ License/Certification #: _____________________________Issuing Authority: _________________________ 4/21/2023 1:49:48 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 2023-Apr-21 13:55:05 Right-Suite® Universal 2022 22.0.07 RSU17457 Page 2 ... J\Young Residence, 826 Ocean Blvd, Atl Bch.rup Calc = MJ8 Front Door faces: E Job:Manual S Compliance Report 4/12/2023Date:1st Floor Front M. EllisBy: Energy Design Systems, Inc., 11727 Brady Rd, Jacksonville, FL 32223 Phone: 904-268-3670 Fax: 904-268-3670 Email: eds.jax@gmail.com Project Information Young ResidenceFor: 826 Ocean Blvd, Atlantic Beach, FL Cooling Equipment Design Conditions °F75.2Entering coil DB:Btuh18793Sensible gain:°F93.9Outdoor design DB: °F63.0Entering coil WB:Btuh3187Latent gain:°F77.2Outdoor design WB: Btuh21981Total gain:°F75.0Indoor design DB: cfm773Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 4TWR5024N1+TEM6A0B24H21Model:TraneManufacturer: cfm773Actual airflow: % of load91Btuh17168Sensible capacity: % of load189Btuh6032Latent capacity: %74SHR:% of load106Btuh23200Total capacity: Heating Equipment Design Conditions °F67.8Entering coil DB:Btuh19983Heat loss:°F39.0Outdoor design DB: °F68.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 4TWR5024N1+TEM6A0B24H21Model:TraneManufacturer: cfm773Actual airflow: °F35Capacity balance:% of load113Btuh22600Output capacity: °F-99Economic balance:Btuh0Supplemental heat required: Meets all requirements of ACCA Manual S. Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Apr-21 13:55:05Right-Suite® Universal 2022 22.0.07 RSU17457 Page 2 ... J\Young Residence, 826 Ocean Blvd, Atl Bch.rup Calc = MJ8 Front Door faces: E Job:Project Summary 4/12/2023Date:1st Floor Front M. EllisBy: Energy Design Systems, Inc., 11727 Brady Rd, Jacksonville, FL 32223 Phone: 904-268-3670 Fax: 904-268-3670 Email: eds.jax@gmail.com Project Information Young ResidenceFor: 826 Ocean Blvd, Atlantic Beach, FL Notes: Design Information Mayport NAF, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F39 Outside db °F94 Inside db °F68 Inside db °F75 Design TD °F29 Design TD °F19 Daily range L Relative humidity %50 Moisture difference gr/lb50 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh16956 Structure Btuh16743DuctsBtuh3027DuctsBtuh2051 Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 (none)(none) Humidification Btuh0 Blower Btuh0 Piping Btuh0 Equipment load Btuh19983 Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load Btuh18793 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average 0Fireplaces Structure Btuh1803 Ducts Btuh1385Central vent (0 cfm)Btuh0 CoolingHeating (none)13681368Area (ft²)Equipment latent load Btuh3187 1381713817Volume (ft³)Air changes/hour 0.150.29 Equipment Total Load (Sen+Lat)Btuh21981 Equiv. AVF (cfm)3666 Req. total capacity at 0.74 SHR ton2.1 Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade TRANE Trade TRANE Model 4TWR5024N1 Cond 4TWR5024N1 AHRI ref 210426219 Coil TEM6A0B24H21 AHRI ref 210426219 Efficiency 7.8 HSPF2 Efficiency 12.3 EER2,15.2 SEER2 Heating input Sensible cooling Btuh17168 Heating output Btuh @ 47°F22600 Latent cooling Btuh6032 Temperature rise °F27 Total cooling Btuh23200 Actual air flow cfm773 Actual air flow cfm773Air flow factor cfm/Btuh0.039 Air flow factor cfm/Btuh0.041 Static pressure in H2O0 Static pressure in H2O0Space thermostat Load sensible heat ratio 0.85 Capacity balance point = 35 °F 2023-Apr-21 13:55:05 Right-Suite® Universal 2022 22.0.07 RSU17457 Page 1 ... J\Young Residence, 826 Ocean Blvd, Atl Bch.rup Calc = MJ8 Front Door faces: E Job:Manual S Compliance Report 4/12/2023Date:1st & 2nd Rear M. EllisBy: Energy Design Systems, Inc., 11727 Brady Rd, Jacksonville, FL 32223 Phone: 904-268-3670 Fax: 904-268-3670 Email: eds.jax@gmail.com Project Information Young ResidenceFor: 826 Ocean Blvd, Atlantic Beach, FL Cooling Equipment Design Conditions °F75.3Entering coil DB:Btuh23028Sensible gain:°F93.9Outdoor design DB: °F63.1Entering coil WB:Btuh4291Latent gain:°F77.2Outdoor design WB: Btuh27319Total gain:°F75.0Indoor design DB: cfm973Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 4TWR5030N1+TEM6A0B30H21Model:TraneManufacturer: cfm973Actual airflow: % of load94Btuh21608Sensible capacity: % of load177Btuh7592Latent capacity: %74SHR:% of load107Btuh29200Total capacity: Heating Equipment Design Conditions °F67.8Entering coil DB:Btuh25229Heat loss:°F39.0Outdoor design DB: °F68.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 4TWR5030N1+TEM6A0B30H21Model:TraneManufacturer: cfm973Actual airflow: °F36Capacity balance:% of load109Btuh27400Output capacity: °F-99Economic balance:Btuh0Supplemental heat required: Meets all requirements of ACCA Manual S. Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Apr-21 13:55:05Right-Suite® Universal 2022 22.0.07 RSU17457 Page 1 ... J\Young Residence, 826 Ocean Blvd, Atl Bch.rup Calc = MJ8 Front Door faces: E Job:Project Summary 4/12/2023Date:1st & 2nd Rear M. EllisBy: Energy Design Systems, Inc., 11727 Brady Rd, Jacksonville, FL 32223 Phone: 904-268-3670 Fax: 904-268-3670 Email: eds.jax@gmail.com Project Information Young ResidenceFor: 826 Ocean Blvd, Atlantic Beach, FL Notes: Design Information Mayport NAF, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F39 Outside db °F94 Inside db °F68 Inside db °F75 Design TD °F29 Design TD °F19 Daily range L Relative humidity %50 Moisture difference gr/lb50 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh20836 Structure Btuh19997DuctsBtuh4393DuctsBtuh3031 Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 (none)(none) Humidification Btuh0 Blower Btuh0 Piping Btuh0 Equipment load Btuh25229 Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load Btuh23028 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average 0Fireplaces Structure Btuh2263 Ducts Btuh2028Central vent (0 cfm)Btuh0 CoolingHeating (none)21582158Area (ft²)Equipment latent load Btuh4291 2308923089Volume (ft³)Air changes/hour 0.140.27 Equipment Total Load (Sen+Lat)Btuh27319 Equiv. AVF (cfm)55103 Req. total capacity at 0.74 SHR ton2.6 Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade TRANE Trade TRANE Model 4TWR5030N1 Cond 4TWR5030N1 AHRI ref 210798234 Coil TEM6A0B30H21 AHRI ref 210798234 Efficiency 8.1 HSPF2 Efficiency 12.0 EER2,15.2 SEER2 Heating input Sensible cooling Btuh21608 Heating output Btuh @ 47°F27400 Latent cooling Btuh7592 Temperature rise °F26 Total cooling Btuh29200 Actual air flow cfm973 Actual air flow cfm973Air flow factor cfm/Btuh0.039 Air flow factor cfm/Btuh0.042 Static pressure in H2O0 Static pressure in H2O0Space thermostat Load sensible heat ratio 0.84 Capacity balance point = 36 °F 2023-Apr-21 13:55:05 Right-Suite® Universal 2022 22.0.07 RSU17457 Page 3 ... J\Young Residence, 826 Ocean Blvd, Atl Bch.rup Calc = MJ8 Front Door faces: E Job:Manual S Compliance Report 4/12/2023Date:2nd Floor Front M. EllisBy: Energy Design Systems, Inc., 11727 Brady Rd, Jacksonville, FL 32223 Phone: 904-268-3670 Fax: 904-268-3670 Email: eds.jax@gmail.com Project Information Young ResidenceFor: 826 Ocean Blvd, Atlantic Beach, FL Cooling Equipment Design Conditions °F75.2Entering coil DB:Btuh17024Sensible gain:°F93.9Outdoor design DB: °F63.0Entering coil WB:Btuh3341Latent gain:°F77.2Outdoor design WB: Btuh20365Total gain:°F75.0Indoor design DB: cfm773Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 4TWR5024N1+TEM6A0B24H21Model:TraneManufacturer: cfm773Actual airflow: % of load101Btuh17168Sensible capacity: % of load181Btuh6032Latent capacity: %74SHR:% of load114Btuh23200Total capacity: Heating Equipment Design Conditions °F67.8Entering coil DB:Btuh14522Heat loss:°F39.0Outdoor design DB: °F68.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 4TWR5024N1+TEM6A0B24H21Model:TraneManufacturer: cfm773Actual airflow: °F27Capacity balance:% of load156Btuh22600Output capacity: °F-99Economic balance:Btuh0Supplemental heat required: Meets all requirements of ACCA Manual S. Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Apr-21 13:55:05Right-Suite® Universal 2022 22.0.07 RSU17457 Page 3 ... J\Young Residence, 826 Ocean Blvd, Atl Bch.rup Calc = MJ8 Front Door faces: E Job:Project Summary 4/12/2023Date:2nd Floor Front M. EllisBy: Energy Design Systems, Inc., 11727 Brady Rd, Jacksonville, FL 32223 Phone: 904-268-3670 Fax: 904-268-3670 Email: eds.jax@gmail.com Project Information Young ResidenceFor: 826 Ocean Blvd, Atlantic Beach, FL Notes: Design Information Mayport NAF, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F39 Outside db °F94 Inside db °F68 Inside db °F75 Design TD °F29 Design TD °F19 Daily range L Relative humidity %50 Moisture difference gr/lb50 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh11604 Structure Btuh15049DuctsBtuh2917DuctsBtuh1975 Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 (none)(none) Humidification Btuh0 Blower Btuh0 Piping Btuh0 Equipment load Btuh14522 Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load Btuh17024 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average 0Fireplaces Structure Btuh2009 Ducts Btuh1332Central vent (0 cfm)Btuh0 CoolingHeating (none)12271227Area (ft²)Equipment latent load Btuh3341 1362013620Volume (ft³)Air changes/hour 0.160.29 Equipment Total Load (Sen+Lat)Btuh20365 Equiv. AVF (cfm)3667 Req. total capacity at 0.74 SHR ton1.9 Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade TRANE Trade TRANE Model 4TWR5024N1 Cond 4TWR5024N1 AHRI ref 210426219 Coil TEM6A0B24H21 AHRI ref 210426219 Efficiency 7.8 HSPF2 Efficiency 12.3 EER2,15.2 SEER2 Heating input Sensible cooling Btuh17168 Heating output Btuh @ 47°F22600 Latent cooling Btuh6032 Temperature rise °F27 Total cooling Btuh23200 Actual air flow cfm773 Actual air flow cfm773Air flow factor cfm/Btuh0.053 Air flow factor cfm/Btuh0.045 Static pressure in H2O0 Static pressure in H2O0Space thermostat Load sensible heat ratio 0.84 Capacity balance point = 27 °F Job #: Performed for: Young Residence 826 Ocean Blvd Atlantic Beach, FL Exclusively for the use of: B&G Plumbing, Heating & Air Conditioning Scale: 1 : 148 Page 1 Right-Suite® Universal 2022 22.0.07 RSU17457 2023-Apr-21 14:01:28 ...nce, 826 Ocean Blvd, Atl Bch.rup N 1st Floor SculleryKitchenDining FoyerLiving Powder Hall 1 Owner Bed Sand Room Owner Bath WC Owner WICStorage Hall 4 107 cfm 63 cfm 31 cfm 41 cfm 89 cfm 85 cfm 22 cfm 77 cfm 51 cfm 67 cfm 53 cfm 310 cfm 715 cfm 43 cfm 43 cfm 148 cfm228 cfm 20 cfm Ret Riser 12 "Sup Riser 12 " 10 "7 "9 " 4 " 6 " 5 " 6 "4 " 6 " 12 " 6 " 12 " 10 " 5 " 7 " 4 " 6 " 5 " 6 " 5 " 16 " 16 " NOTE: HVAC Contractor to verify in field duct layout compatibility with building structure and coordinate installation with other trades. Job #: Performed for: Young Residence 826 Ocean Blvd Atlantic Beach, FL Exclusively for the use of: B&G Plumbing, Heating & Air Conditioning Scale: 1 : 148 Page 2 Right-Suite® Universal 2022 22.0.07 RSU17457 2023-Apr-21 14:01:28 ...nce, 826 Ocean Blvd, Atl Bch.rup N 2nd Floor Bed 1 Bed 2 WIC 2Vestibule Bath 2 Bath 1 WIC 1Powder 2 Family Room Storage 2 Landing Vestibule 2 Bed 3 Bath 3 WIC 3 Storage 3 Hall 2 WIC Bonus Bath Bonus Hall 3 55 cfm 50 cfm 12 cfm 37 cfm 47 cfm 8 cfm 27 cfm 168 cfm 5 cfm 131 cfm 98 cfm 5 cfm 47 cfm 31 cfm 130 cfm 19 cfm 92 cfm 63 cfm 235 cfm 167 cfm 4 cfm 316 cfm 98 cfm 115 cfm 115 cfm 629 cfm Sup Riser 12 " Ret Riser 12 " 14 " 5 " 4 " 14 " 5 " 14 " 7 " 4 " 7 " 4 " 7 " 5 " 4 " 6 " 6 " 5 " 5 " 8 " 10 " 4 " 4 " 8 " 16 " 4 " 4 " 7 " 7 " 16 " 7 " 9 " NOTE: HVAC Contractor to verify in field duct layout compatibility with building structure and coordinate installation with other trades. Bold/italic values have been manually overridden 2023-Apr-21 14:01:14 Right-Suite® Universal 2022 22.0.07 RSU17457 Page 1 ... D\Young Residence, 826 Ocean Blvd, Atl Bch.rup Calc = MJ8 Front Door faces: E Job:Duct System Summary Date: Zone 1 By: Exclusively for the use of:, B&G Plumbing, Heating & Air Conditioning Project Information Young ResidenceFor: 826 Ocean Blvd, Atlantic Beach, FL CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.389 / 0.111 in H2O in H2O0.389 / 0.111 Lowest friction rate in/100ft0.158in/100ft0.158 Actual air flow cfm715cfm715 Total effective length (TEL)ft316 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st2130.050.0VlFx0x05.00.21641431589hDining st2130.037.0VlFx0x05.00.23341431589hDining-A st2150.073.0VlFx0x06.00.17562632320hFoyer st290.018.0VlFx0x010.00.36031030011691cHall 1-C st2170.057.0VlFx0x05.00.17138411517hKitchen st2130.061.0VlFx0x06.00.20486893293hLiving st2110.024.0VlFx0x04.00.29031311158hPowder st2180.066.0VlFx0x07.00.1581071064054cScullery Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st2 Peak AVF 715 715 0.158 512 16.0 0x0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb2 0x 7150 715 70.0 0.158 512 16.0 x0 0 VlFx Bold/italic values have been manually overridden 2023-Apr-21 14:01:14 Right-Suite® Universal 2022 22.0.07 RSU17457 Page 2 ... D\Young Residence, 826 Ocean Blvd, Atl Bch.rup Calc = MJ8 Front Door faces: E Job:Duct System Summary Date: Zone 2 By: Exclusively for the use of:, B&G Plumbing, Heating & Air Conditioning Project Information Young ResidenceFor: 826 Ocean Blvd, Atlantic Beach, FL CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.360 / 0.140 in H2O in H2O0.360 / 0.140 Lowest friction rate in/100ft0.108in/100ft0.108 Actual air flow cfm980cfm980 Total effective length (TEL)ft462 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st6150.027.1VlFx0x05.00.20363612583cBath 3 st6130.024.1VlFx0x06.00.23492853756cBed 3 st6230.051.1VlFx0x04.00.1281210483cBonus Bath st6260.073.1VlFx0x07.00.1081151134695cBonus-A st6250.061.1VlFx0x07.00.1161151134695cBonus-B st6210.055.1VlFx0x07.00.13698963998cHall 2 st6230.043.1VlFx0x04.00.13227261099cHall 3 st5140.031.1VlFx0x06.00.21080853251hHall 4 st3100.043.1VlFx0x06.00.25276772954hOwner Bath st5120.032.1VlFx0x05.00.23745511933hOwner Bed st5180.053.1VlFx0x04.00.1551922843hOwner WIC st5200.044.1VlFx0x06.00.14862672573hSand Room st5220.061.1VlFx0x06.00.12850532015hStorage st6190.037.1VlFx0x05.00.15937311500cStorage 3 st6110.016.1VlFx0x05.00.28647471927cVestibule 2 st5160.051.1VlFx0x04.00.1711920753hWC st6230.058.1VlFx0x04.00.12554195cWIC st6170.042.1VlFx0x04.00.1701916763cWIC 3 2023-Apr-21 14:01:14 Right-Suite® Universal 2022 22.0.07 RSU17457 Page 3 ... D\Young Residence, 826 Ocean Blvd, Atl Bch.rup Calc = MJ8 Front Door faces: E Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st5 Peak AVF 298 275 0.128 547 10.0 0x0 VinlFlx st3 st3 Peak AVF 376 351 0.128 478 12.0 0x0 VinlFlx st4 Peak AVF 604 629 0.108 588 14.0 0x0 VinlFlx st6 Peak AVF 604 629 0.108 588 14.0 0x0 VinlFlx st4 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb5 0x 1480 140 82.7 0.169 554 7.0 x0 0 VlFx rt3 rb6 0x 2280 211 116.7 0.120 515 9.0 x0 0 VlFx rt3 rb9 0x 6040 629 129.2 0.108 588 14.0 x0 0 VlFx Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt3 Peak AVF 376 351 0.120 478 12.0 0x0 VinlFlx Bold/italic values have been manually overridden 2023-Apr-21 14:01:14 Right-Suite® Universal 2022 22.0.07 RSU17457 Page 4 ... D\Young Residence, 826 Ocean Blvd, Atl Bch.rup Calc = MJ8 Front Door faces: E Job:Duct System Summary Date: Zone 3 By: Exclusively for the use of:, B&G Plumbing, Heating & Air Conditioning Project Information Young ResidenceFor: 826 Ocean Blvd, Atlantic Beach, FL CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.348 / 0.152 in H2O in H2O0.348 / 0.152 Lowest friction rate in/100ft0.130in/100ft0.130 Actual air flow cfm715cfm715 Total effective length (TEL)ft386 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st190.011.0VlFx0x05.00.34549501307hBath 1 st1230.039.0VlFx0x05.00.13047471218cBath 2 st1130.027.0VlFx0x07.00.2221301313412hBed 1 st1210.047.0VlFx0x07.00.1361271303401hBed 2 st1190.024.0VlFx0x07.00.16398912905cFamily Room st1110.010.0VlFx0x08.00.2901631684396hLanding st1150.014.0VlFx0x04.00.21254146cPowder 2 st1230.031.0VlFx0x06.00.13452551434hStorage 2 st1170.034.0VlFx0x04.00.17186234cVestibule st1150.020.0VlFx0x04.00.20543122cWIC 1 st1170.041.0VlFx0x04.00.1653031813hWIC 2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 715 715 0.130 512 16.0 0x0 VinlFlx 2023-Apr-21 14:01:14 Right-Suite® Universal 2022 22.0.07 RSU17457 Page 5 ... D\Young Residence, 826 Ocean Blvd, Atl Bch.rup Calc = MJ8 Front Door faces: E Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb3 0x 2350 234 97.0 0.156 532 9.0 x0 0 VlFx rt1 rb7 0x 1670 166 117.0 0.130 478 8.0 x0 0 VlFx rt1 rb8 0x 3130 316 57.0 0.266 579 10.0 x0 0 VlFx rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 715 715 0.130 512 16.0 0x0 VinlFlx