Loading...
392 11TH ST RESA23-0027 Brimblecomb Residence - Permit Set-Rev. 10-31-23_110/30/2023 1:22:41 PM23.01.32BRIMBLECOMB RESIDENCE392 11TH STREETATLANTIC BEACHPERMIT SET -23.10.30CLIENTMRS. AND MR. BRIMBLECOMBARCHITECTdig ARCHITECTURE LLC13500 SUTTON PARK DR. SOUTH, SUITE 301JACKSONVILLE, FL 32224904-553-2698www.dig-architecture.comGENERAL CONTRACTOR10/30/2023 1:22:41 PM23.01.32BRIMBLECOMB RESIDENCE392 11TH STREETATLANTIC BEACH392 11th STREET, ATLANTIC BEACH, FLBOSCO BUILDING CONTRACTORS2158 MAYPORT ROADJACKSONVILLE, FL 32233Nicholas James RenardDigitally signed by Nicholas James Renard Date: 2023.10.30 13:24:39 -04'00'By vangers at 11:43 am, Oct 31, 20231:50 pm, Oct 31, 2023By Mike Jones at 1:50 pm, Oct 31, 2023By Brian Broedell at 4:59 pm, Oct 31, 2023 DRAWING NOTES:DRAWINGS ARE NOT TO BE SCALED FOR INFORMATION.ALL EXTERIOR WALLS ARE 2x6.ALL INTERIOR WALLS ARE 2x4 EXCEPT AS NOTED.ALL WALL THICKNESSES ARE ACTUAL 2x4 = 3-1/2", 2x6 = 5-1/2", 2x8 = 7-1/4", ETC.THE SIZE AND QUANTITY OF ALL EXTERIOR STEPS ARE TO BE FIELD DETERMINED BY OTHERS.ALL PLATE AND CEILING HEIGHTS ARE TAKEN FROM (TOP OF) HOUSE SLAB/BLOCK.ALL ANGLES ARE 45° UNLESS OTHERWISE NOTED.NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS.ALL DIMENSIONS ARE TO FACE OF BLOCK OR STUD WALL.ALL WOOD IN CONTACT WITH MASONRY, CONCRETE OR EARTH SHALL BE PRESSURE TREATED APPROPRIATELY FOR THE CONDITION. H = HAZARDOUS GLASS LOCATIONS.VERIFY THE KITCHEN AND VANITY LAYOUTS WITH THE DETAILS DONE BY OTHERS.CEILING HEIGHTS ARE DIMENSIONED IN RELATIONSHIP TO THE FINISHED FLOOR AND/OR DECK.1.2.3.4.5.6.7.8.9.10.11.12.13.LOCATION MAPATTACHMENTS NOT INCLUDED:LEGAL SURVEYTRUSS ENGINEERINGFLORIDA ENERGY SHEETS1.2. 3. PROJECT LOCATIONIT IS INTENDED THAT THESE DRAWINGS ARE PREPARED FOR BUILDINGS THAT WILL CONFORM TO THE 2020 FLORIDA BUILDING CODE, RESIDENTIAL.THE MAXIMUM ALLOWABLE NUMBER OF STORIES AND HEIGHT PER LOCAL ZONING ORDINANCES AND PER THE 2014 FLORIDA BUILDING CODE, RESIDENTIAL, ARE AS FOLLOWS:A. MAX. NO. OF STORIES = (3)B. MAX. HEIGHT = 35' FROM GRADETHE BUILDING CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE TO THE CODE REGUARDLESS OF ANY MISSING OR INCOMPLETE DETAILS OR NOTES.THE BUILDING CONTRACTOR AND HIS SUBCONTRACTORS SHALL CONFORM TO ANY LOCAL ORDINANCES AND SHALL VERIFY ALL DIMENSIONS, MATERIALS, AND CONDITIONS AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH HIS WORK.VERIFY ALL FIELD CONDITIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK.MAINTAIN A CURRENT AND COMPLETE SET OF CONTRACT DOCUMENTS AT THE JOB SITE.THE ELECTRICAL FLOOR PLAN IS INTENDED TO ONLY SUGGEST LOCATIONS FOR FIXTURES, OUTLETS, AND SWITCHES.ELECTRICAL, MECHANICAL, PLUMBING, AND OTHER BUILDING SYSTEMS, IF ANY, ARE TO BE DESIGNED, ENGINEERED AND ARE THE SOLE RESPONSIBILITY OF OTHERS.ALL INTERIOR AND EXTERIOR FLOOR & STEP FINISHES SHALL HAVE A NON-SLIP FINISH TO MEET ASTM C1028 STATIC COEFFICIENT OF FRICTION MIN. OF 0.6.ERECT AND MAINTAIN, AS REQUIRED BY EXISTING FIELD CONDITIONS, THROUGHOUT THE ENTIRE PORTION OF THE WORK, ALL SAFEGUARDS AND BARRICADES FOR SAFETY INCLUDING POSTING WARNING SIGNS, ENFORCING SAFETY REGULATIONS AND PROTECTION OF PROPERTY.CHECK ALL CEILING HEIGHTS AND POSSIBLE CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCT-WORK AND ALL OTHER CONSTRAINTS TO ASSURE THE LOCATION OF THE LIGHT FIXTURES AS SHOWN ON THE LIGHTING PLAN. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IN WRITING BEFORE PROCEEDING WITH THE WORK.CONTRACTOR TO POST AND MAINTAIN SIGNAGE FORBIDDING THE USE OF NICOTINE PRODUCTS THROUGOUT ALL PHASES OF CONSTRUCTION. NICOTINE PRODUCTS ARE NOT TO BE ALLOWED WITHIN THE PERIMETER OF THE BUILDING FOOTPRINT.GENERAL CONSTRUCTION NOTES:BUILDING CODE SUMMARYGENERAL NOTES1.2. 3. 4. 5. 6.7. 8.9.10.11.TYPE VB UN-PROTECTEDOCCUPANCY CLASS -GROUP R-3THE 2020 FLORIDA BUILDING CODE, RESIDENTIAL:DRAWING INDEXX.XXXEXTERIOR ELEVATION IDENTIFICATIONWALL SECTION IDENTIFICATIONX.XXXTYPICAL DETAIL DESIGNATIONROOM NUMBER IDENTIFICATIONX.XXXDETAIL NUMBERSHEET WHERE DETAIL IS SHOWNDOOR NUMBER IDENTIFICATIONWINDOW NUMBER IDENTIFICATIONXCEILING HEIGHT IDENTIFICATIONWALL TYPE IDENTIFICATIONX.XXXINTERIOR ELEVATION IDENTIFICATION100MATERIALX'-X" AFFA100ROOMSYMBOL LEGENDFRAMING DIMENSIONSFINISH FACE DIMENSIONSDIM.DIM.CABINET DIMENSIONSDIM.X.XXXDETAIL NUMBERSHEET WHERE DETAIL IS SHOWNENLARGED PLANS:ENLARGED PLANS / INTERIOR DESIGN:EXISTING RESIDENCEICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID :REVISIONSPERMIT :10/30/2023 1:22:41 PM23.01.32BRIMBLECOMB RESIDENCEINDEX23.10.30-392 11TH STREETATLANTIC BEACHA100122.07.13-SHEETNO.SHEET NAMEREVISION 1REVISION 2REVISION 3A1001 INDEXARCHITECTURALA2001 SITE PLANA2201 FLOOR PLANSA2202 CEILING & ELECTRICAL PLANSA2203 ELEVATIONSA2204 SECTIONSA2205 DETAILS - STAIR UPEXISTING RESIDENCE(NO WORK)EXISTING PAVER DRIVEWAYEXISTING SINGLE STORY GARAGE, EXISITNG POSITION IN SIDEYARD SETBACKEXISTING POOL (NO WORK)7.5' SIDEYARD SETBACK 7.5' SIDEYARD SETBACK 10' REAR SETBACKNEW STAIRSECOND FLOOR ADDITION (SHOWN WITH RED HATCH) ADDITION SITS WITHIN REQUIRED SETBACKS11TH STREETNOTE:NO NEW LOT COVERAGE AS PART OF THIS REMODEL.1/8" = 1'-0"A20011SITE PLAN - ARCHITECTURALICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID :REVISIONSPERMIT :10/30/2023 1:22:41 PM23.01.32BRIMBLECOMB RESIDENCESITE PLAN23.10.30-392 11TH STREETATLANTIC BEACHA200122.07.13-1:50 pm, Oct 31, 2023 UPUPUPEXISTING24' - 0"EXISTING24' - 0"4' - 1"A220512A22042A22043A22043A2204EXISTING FIRST FLOOREXISTING GARAGE0011' - 11 1/2"20' - 4 1/2"A22045A2205222' - 4"24' - 0"4' - 8"6' - 3"2' - 0"11' - 1"4' - 1"10' - 10 1/2"13' - 2 1/2"9' - 10"4' - 2"4' - 1"4' - 3"3' - 6"8' - 6"7' - 10 1/2"2' - 5 1/2"2A22042A22043A22043A2204DINING/LIVING ROOM201BEDROOM202W.I.C203BATHROOM204PANTRY201A201B204A202204C203204BBAAAAAA22' - 4"2' - 5"5' - 11"2' - 0"8' - 6"3' - 6"5' - 5 1/2"7' - 9"5' - 4"5' - 5 1/2"13' - 2 1/2"10' - 9 1/2"A220447' - 5 77/128"SLOPE: 4"/12"SLOPE: 4"/12"MATCH EXISTINGMATCH EXISTINGOVERHANGGUTTERSLOPE: 4"/12"SLOPE: 4"/12"DSDSSLOPE: 4"/12"020102ICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID :REVISIONSPERMIT :10/30/2023 1:22:42 PM23.01.32BRIMBLECOMB RESIDENCEFLOOR PLANS23.10.30-392 11TH STREETATLANTIC BEACHA220122.07.13-1/4" = 1'-0"A22011DIMENSION PLAN - FIRST FLOORWINDOW SCHEDULEWINDOW SIZEHEADHEIGHTTYPE COMMENTSA 36" x 48" 7' - 0" SINGLE HUNG MATCH EXISTINGB 24" x 48" 7' - 0" SINGLE HUNG MATCH EXISTING1/4" = 1'-0"A22012DIMENSION PLAN - SECOND FLOORDOOR SCHEDULE - SECOND FLOORDOOR NO. TYPE MFG. STYLE FINISH COMMENTS201A 36" x 84" TBD MATCH PAINT201B 30" x 80" MATCH PAINT202 2'-8" x 6'-8" TBD MATCH PAINT203 2'-6" x 6'-8" TBD MATCH PAINT POCKET204A 2'-8" x 6'-8" TBD MATCH PAINT204B 2'-6" x 6'-8" TBD MATCH PAINT POCKET204C 2'-8" x 8'-0" TBD GLASS N/A SHOWER DOOR1/4" = 1'-0"A22014ROOF PLAN1/4" = 1'-0"A22015DEMO FLOOR PLANDEMO NOTESNUMBERDESCRIPTION01 DEMO EXISTING CEILING02 DEMO EXISTING ROOF1:51 pm, Oct 31, 2023 3D4D33333GFIGFI33220WPGFITVTA.F.F.GWB10' - 0"EXISTING GARAGE001AAA.F.F.GWB8' - 0"A.F.F.GWB8' - 0"A.F.F.GWB8' - 0"A.F.F.GWB8' - 0"DINING/LIVING ROOM201BEDROOM202W.I.C203BATHROOM204BBBBBBBBBBBBBBBBBBCDEEELECTRICAL NOTES24"X48" FLUORESCENT FIXTUREPRE-WIRE AND BRACE FOR CEILING FAN W/ LIGHTWALL MTD. LIGHT AT 72" A.F.F.PENDANT LIGHT FIXTUREUNDER CABINET LITES12"X48" FLUORESCENT FIXTUREDIMMER SWITCH AT 42" A.F.F.4-WAY SWITCH AT 42" A.F.F.3-WAY SWITCH AT 42" A.F.F.SWITCH AT 42" A.F.F.SURFACE MTD. CEILING LIGHTPRE-WIRE AND BRACE FOR CEILING FANPUSH BUTTONFLOOD LIGHTSHOLLYWOOD STRIPELECTRICAL SWITCH AND LIGHT LEGEND(SEE NOTE 3)RECESS (EYEBALL) LIGHTINGRECESS LIGHTINGSMOKE AND CARBON MONOXIDE DETECTOREXHAUST FAN WITH LIGHTCEILING MTD. EXHAUST FANE.B.SDFAN/ LIGHTLOCATE ALL ELECTRICAL OUTLETS, SWITCHES, LIGHTS, SMOKE DETECTORS, FANS, AND EXHAUST FANS PER ELECTRICAL/ BUILDING CODES. VERIFY WITH BUILDER ANY SPECIAL HOOK-UPS. (RANGE HOODS, FIREPLACE FANS, LANDSCAPE LITES, SPRINKLER SYSTEM, SECURITY SYSTEM, INTERCOM SYSTEM, VACUUM SYSTEM, SWIMMING POOL, PUMPS, ETC.) INSTALL WATER/VAPOR PROOF FIXTURES IN SHOWERS AND OVER TUBS AS REQUIRED.1. 2. 3.GENERAL ELECTRICAL NOTESELECTRICAL SERVICE IS LESS THAN 600 AMPS. CALCULATION TO BE PROVIDED BY ELECTRICIAN.PROVIDE SMOKE DETECTORS PER NFPA72 A-81.2 AND CARBON MONOXIDE ALARMS PER R315 OF THE 2020 FBC-R.1. 2.CONTRACTOR ELECTRICAL NOTESSPECIFICATIONS, PRICE SUMMARY AND CHANGE ORDERS SUPERSEDE THIS ELECTRICAL PLAN.THE PURPOSE OF THIS PLAN IS TO OBTAIN AN ELECTRICAL PERMIT. FIXTURE, SWITCH AND RECEPTACLE LOCATIONS SHOWN MAY VARY DUE TO FRAMING, MECHANICAL CONFLICTS, SITE CONDITIONS OR LOCAL BUILDING CODE REQUIREMENTS.THE PURCHASER WILL DO AN ELECTRICAL WALK THROUGH WITH THE PROJECT MANAGER DURING CONSTRUCTION. THIS WALK THROUGH WILL IDENTIFY THE PREDETERMINED LOCATION OF RECEPTACLES BY THE ELECTRICIANS FOLLOWING LOCAL BUILDING CODES. AT THIS TIME, SELECTIVE LIGHT FIXTURES, PHONE AND TV JACKS WILL BE DETERMINED BY THE PURCHASER AS TO THE PREFERRED LOCATIONS.1. 2.3.FAN3-WAY DIMMER SWITCH AT 42" A.F.F.EXISTING GARAGE001DINING/LIVING ROOM201BEDROOM202W.I.C203PULL CHAIN110 V. FLR. MTD. DUPLEX OUTLETDOOR CHIMESA/C DISCONNECTTHERMOSTATTELEVISION JACKTELEPHONE JACKELECTRICAL METERELECTRICAL PANELELECTRICAL OUTLET LEGEND220 V. OUTLET110 V. DUPLEX OUTLET1/2 SWITCH DUPLEX OUTLET110 V. G.F.I. DUPLEX OUTLETWEATHER PROOF G.F.I.TPFPICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID :REVISIONSPERMIT :10/30/2023 1:22:43 PM23.01.32BRIMBLECOMB RESIDENCECEILING & ELECTRICAL PLANS23.10.30-392 11TH STREETATLANTIC BEACHA220222.07.13-1/4" = 1'-0"A22021CEILING PLAN - FIRST FLOORLIGHTING FIXTURE SCHEDULE - EXTERIORFIXTURE FIXTURE TYPE MOUNTMOUNTINGHEIGHTCOUNT6 EXTERIOR SCONCE - GARAGE3LIGHTING FIXTURE SCHEDULE - INTERIORFIXTURE FIXTURE TYPE MOUNTMOUNTINGHEIGHTCOUNTA GARAGE CEILING MOUNTED FIXTURE CEILING 4B 4" SQUARE LED - INTERIOR CEILING 19C CEILING MOUNTED FIXTURE - LIVING ROOM CEILING 1D INTERIOR - CEILING FAN BEDROOM CEILING 1E SCONCE - BATH 01WALL 21/4" = 1'-0"A22022CEILING PLAN - SECOND FLOOR1/4" = 1'-0"A22023ELECTRICAL PLAN - FIRST FLOOR1/4" = 1'-0"A22024ELECTRICAL PLAN - SECOND FLOOR1:51 pm, Oct 31, 2023 EXISTING GRADE0"SECOND FLOOR11' -6"PLATE -SECOND FLOOR19' -6"EXISTING TOP OF FOOTING-1' -6"EXISTING PLATE -FIRST FLOOR10' -0"TOP OF ROOF24' -9 3/64"AAE1EXISTING GRADE0"SECOND FLOOR11' -6"PLATE -SECOND FLOOR19' -6"EXISTING TOP OF FOOTING-1' -6"EXISTING PLATE -FIRST FLOOR10' -0"TOP OF ROOF24' -9 3/64"EXISTING TOP OF ROOF16' -7"BAAE1EXISTING GRADE0"SECOND FLOOR11' -6"PLATE -SECOND FLOOR19' -6"EXISTING TOP OF FOOTING-1' -6"EXISTING PLATE -FIRST FLOOR10' -0"TOP OF ROOF24' -9 3/64"EXISTING TOP OF ROOF16' -7"E1EXISTING GRADE0"SECOND FLOOR11' -6"PLATE -SECOND FLOOR19' -6"EXISTING TOP OF FOOTING-1' -6"EXISTING PLATE -FIRST FLOOR10' -0"TOP OF ROOF24' -9 3/64"EXISTING TOP OF ROOF16' -7"AA201A24' - 9 3/64"2' - 11"5' - 1"1' - 6"10' - 0"1' - 6"21' - 0"19' - 6"E145° CUTALL FLASHING SHALL BE SELF ADHERING AND ROLLED FLAT AND SMOOTHWINDOWS AND FLASHING SHALL BE INSTALLED IN ACCORDANCE WITH FBC-R703.8 AND AMMA 711, 100, 200 AND 250EXTERIOR WINDOW FLASHING DETAILS -WOOD FRAME9"9"6"6"2"2"1/2"1"1"1"2"FOLD THE BOTTOM AND SIDE FLAPS OVER AND BEHIND THE INTERIOR SIDE OF THE FRAMING.CUT HOUSE WRAP INTO MODIFIED " i " PATTERN.CUT HOUSE WRAPAND FOLD INTOOPENING AT JAMBS.TAPE TOP FLAP UPTEMPORARILY.CUT SILL FLASHING THE LENGTHOF THE SILL AND UP THE JAMBS6" TO FORM AN END DAM.THE FLASHING SILL PAN SYSTEM SHALL COVER THE SILL TO AT LEAST THE DEPTH OF THE WINDOW PLUS 2" ONTO THE FACE OF THE HOUSE WRAP DRAINAGE PLANE.RUN A CONT. BEAD OF SEALANT ON THE BACK SURFACE (INT. FACE) OF THE MOUNTING FLANGE OF THE WINDOW AT THE HEAD AND BOTH JAMBS. APPLY SEALANT IN LINE WITH ANY PRE-PUNCHED HOLES OR SLOTS IN THE MOUNTING FLANGE. CONNECT THE BEAD OF SEALANT ACROSS ANY JOINERY ON THE WINDOW FRAME AT ALL FOUR CORNERS. APPLY A DISCONTINUOUS BEAD OF SEALANT ON THE INT. SURFACE OF THE MOUNTING FLANGE AT THE SILL. THE BEAD OF SEALANT SHALL HAVE A MINIMUM OF TWO 2" VOIDS NEAR THE ENDS ALLOWING ANY LIQUID THAT HAS ENTERED THE WINDOW OPENING TO EXIT.FASTEN THE WINDOW PERIMETER SECURELY INTO POSITION ACCORDINGTO THE MANUFACTURERS INSTRUCTIONS.APPLY FLASHING OVER THE MOUNTING FLANGES OF THE WINDOW AT BOTH JAMBS. THE SELF-ADHERING FLASHING SHALL BE A MINIMUM OF 4" IN WIDTH AND EXTEND 1" BELOW THE BOTTOM OF THE SILL FLASHING AND 1/2" BELOW WHERE THE TOP EDGE OF THE HEAD FLASHING WILL BE INSTALLED.APPLY HEAD FLASHING EXTENDING 1" BEYOND THE OUTSIDE EDGE OF OF THE FLASHING AT THE JAMBS.RELEASE FLAP OF HOUSE WRAP OVER THE HEAD FLASHING AND COVER DIAGONAL CUT IN HOUSE WRAP WITH TAPE 2" LONGER THAN CUT.INSTALL SHIMS AS NEEDED TO MAINTAIN A MINIMUM OF 1/4" SPACING AROUND WINDOW FRAME. INSTALL BACKER ROD AS NEEDED TO AIR SEAL AROUND FRAME. USE SEALANT TO CREATE A BACK DAM TO DIRECT LIQUID TO THE OUTSIDE OF THE WINDOW AT THE SILL FLANGE. INSTALL SEALANT AROUND THE INTERIOR PERIMETER TO COMPLETE THE INSTALLATION.45° CUTALL FLASHING SHALL BE SELF ADHERING AND ROLLED FLAT AND SMOOTHEXTERIOR DOOR FLASHING DETAILS9"9"8 1/2"10"2"CUT HOUSE WRAP AND FOLD INTO OPENINGS AT JAMBSTAPE TOP FLAP UP TEMPORARILYINSTALL DOOR SILL SEALNAT AT THRESHOLD PER MFG'S REQUIREMENTS, INSTALL DOOR PLUMB AND SQUAREAPPLY JAMB FLASHING TO BOTH SIDES OF DOOR, DOOR FRAME AND HOUSE WRAP EXTENDING 8 1/2" ABOVE DOOR HEADAPPLY HEAD FLASHING EXTENDING 10" BEYOND BOTH DOOR JAMBSRELEASE TOP FLAP AND COVER DIAGONAL CUT IN HOUSE WRAP WITH TAPE 2" LONGER THAN CUTICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID :REVISIONSPERMIT :10/30/2023 1:22:44 PM23.01.32BRIMBLECOMB RESIDENCEELEVATIONS23.10.30-392 11TH STREETATLANTIC BEACHA220322.07.13-1/4" = 1'-0"A22031FRONT ELEVATION1/4" = 1'-0"A22032LEFT SIDE ELEVATION1/4" = 1'-0"A22033REAR ELEVATION1/4" = 1'-0"A22034RIGHT SIDE ELEVATION1/4" = 1'-0"A2203AWINDOW FLASING1/4" = 1'-0"A2203BDOOR FLASHINGEXTERIOR WALL SCHEDULEMARK WALL FINISH TYPE NOTESE1 MATCH EXISTINGBy Mike Jones at 1:51 pm, Oct 31, 2023 EXISTING GRADE0"SECOND FLOOR11' -6"PLATE -SECOND FLOOR19' -6"EXISTING TOP OF FOOTING-1' -6"EXISTING PLATE -FIRST FLOOR10' -0"TOP OF ROOF24' -9 3/64"EXISTING TOP OF ROOF16' -7"3A22043A2204202204A201BA22041SimEXISTING GRADE0"SECOND FLOOR11' -6"PLATE -SECOND FLOOR19' -6"EXISTING TOP OF FOOTING-1' -6"EXISTING PLATE -FIRST FLOOR10' -0"TOP OF ROOF24' -9 3/64"2A22042A2204203204BEXISTING GRADE0"SECOND FLOOR11' -6"PLATE -SECOND FLOOR19' -6"EXISTING TOP OF FOOTING-1' -6"EXISTING PLATE -FIRST FLOOR10' -0"EXISTING TOP OF ROOF16' -7"1/2" PLYWOOD WITH WATERRESISTANT MEMBRANEROOF FRAMING, REFER TO STRUCTURALDRAWINGS FOR MORE INFORMATIONFASCIA-BUILT-UP 1X6 W 1X4CONTINUOUS PRE-FINISHED METAL DRIP EDGE1/2" G.W.B2x4 WOOD STUDSFINISH FLOOR AS SCHEDULED(2) 2"x6" #2 TOP PLATE AND HURRICANE CLIPS, REFER TO STRUCTURAL DRAWINGSBATT INSULATION1/2" G.W.BWINDOW AS SCHEDULEDFLOOR TRUSSES, REFER TO STRUCTURALDRAWINGS FOR MORE INFORMATION1/2" G.W.BLAP SIDING, PRIME AND PAINTFRAMED HEADER, REFER TO STRUCTURAL DRAWINGS FOR SIZESILL PLATESILL,PRIME AND PAINTPLYWOOD (REFER TO STRUCUTRAL DRAWINGS FOR MI. THICKNESS) WITH WATER RESISTANT MEMBRANE5V -CRIMP METAL ROOF, RESIDENTIAL MILL FINISH 26 GAUGE, 30° FELT UNDERLAYMENT2X8 FRIEZE BOARDEXISTING GARAGE DOOREXISTING PERGOLAEXISTING GRADE GARAGE FLOORBATT INSULATIONPRE-FINISHED ALUMINUM BOX GUTTEREXISTING FOOTING24 1/2"19"19 1/2"15"15"SHOWER VALVESHOWER HEAD44 1/2"32"COUNTER108"5' - 0"7' - 5"COUNTER149"ICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID :REVISIONSPERMIT :10/30/2023 1:22:46 PM23.01.32BRIMBLECOMB RESIDENCESECTIONS23.10.30-392 11TH STREETATLANTIC BEACHA220422.07.13-1/4" = 1'-0"A22042BUILDING SECTION 011/4" = 1'-0"A22043BUILDING SECTION 021/2" = 1'-0"A22041WALL SECTION 011/2" = 1'-0"A22045BATHROOM - ENLARGED PLAN SECOND FLOOR1/2" = 1'-0"A22044DINETTE - ENLARGED FLOOR PLAN SECOND FLOOR 5A22055A22054A22054A22054' - 1"4' - 8 1/2"15' - 8"20' - 4 1/2"5A22055A22054A22054A220515' - 8"4' - 8 1/2"EXISTING GRADE0"SECOND FLOOR11' -6"PLATE -SECOND FLOOR19' -6"EXISTING TOP OF FOOTING-1' -6"EXISTING PLATE -FIRST FLOOR10' -0"EXISTING TOP OF ROOF16' -7"18 RISERS11' - 0"EXISTING GRADE0"SECOND FLOOR11' -6"PLATE -SECOND FLOOR19' -6"EXISTING TOP OF FOOTING-1' -6"EXISTING PLATE -FIRST FLOOR10' -0"EXISTING TOP OF ROOF16' -7"18 RISERS11' - 0"ICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID :REVISIONSPERMIT :10/30/2023 1:22:46 PM23.01.32BRIMBLECOMB RESIDENCEDETAILS - STAIR23.10.30-392 11TH STREETATLANTIC BEACHA220522.07.13-1/2" = 1'-0"A22052STAIR DETAIL - SECOND FLOOR1/2" = 1'-0"A22051STAIR DETAIL - FIRST FLOOR1/2" = 1'-0"A22055STAIR DETAIL - SECTION 021/2" = 1'-0"A22054STAIR DETAIL - SECTION 01A220533D STAIR DETAIL