Loading...
325 SARGO RD ROOF23-0075 Mod Bit Product Approval 11-2-23_1NEMO|etc. NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29 Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 9 of 74 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: W-23 Min. 15/32-inch plywood, 24- inch span Min. 2-inch ACFoam II or H- Shield Note 2 1 per 2.7 ft2 Min. 2-inch H-Shield HD Composite M-OSFA or M-PG1 SBS-SA (Optional) SBS-SA SBS-SA -30.0 HYBRID SYSTEMS: W-24 Min. 15/32-inch plywood, 24- inch span Min. 2-inch ACFoam II or H- Shield Note 2 1 per 2.7 ft2 Min. 2-inch H-Shield HD Composite M-OSFA or M-PG1 SBS-SA-H (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -30.0 W-25 Min. 15/32-inch plywood, 24- inch span Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP or #14 HD with Trufast 3”Metal Insulation Plates 1 per 1.3 ft2 Min. 1.5-inch ACFoam II or H-Shield hot asphalt, M-OSFA, M-PG1 Insta Stik, OB500 SBS-SA-H (Optional) APP-TA APP-TA -67.5 CONVENTIONAL SYSTEMS: W-26 Min. 23/32-inch plywood, 24- inch span Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield Note 2 1 per 2.0 ft2 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous) hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-27 Min. 23/32-inch plywood, 24- inch span Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield Note 2 1 per 2.0 ft2 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board hot asphalt BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-28 Min. 15/32-inch plywood, 24- inch span Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP or #14 HD with Trufast 3”Metal Insulation Plates 1 per 1.3 ft2 Optional additional layer(s) of base insulation followed by Min. 0.25- inch SECUROCK Gypsum-Fiber Roof board hot asphalt, M-OSFA, M-PG1, Insta Stik, OB500 APP-TA (Optional) APP-TA APP-TA -90.0 COLD-APPLIED SYSTEMS: W-29 Min. 15/32-inch plywood, 24- inch span Min. 2-inch ACFoam II or H- Shield Note 2 1 per 2.7 ft2 Min. 2-inch H-Shield HD Composite M-OSFA or M-PG1 SBS-CA4 None SBS-CA4 -30.0 NEMO|etc. NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29 Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 10 of 74 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 3, Note 13) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: W-30 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 3.2 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -30.0* W-31 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Note 2 1 per 1.3 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -45.0 W-32 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -45.0* W-33 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3, H-Shield or Multi- Max FA3 Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -45.0* W-34 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -52.5 W-35 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3, H-Shield or Multi- Max FA3 Note 2 1 per 1.45 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -60.0 HYBRID SYSTEMS: W-36 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck, DensDeck Prime Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 None SBS-SA- H (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -30.0* W-37 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA APP-TA -52.5 W-38 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.3 ft2 None SBS-SA- H (Optional) BP- AA or SBS-AA SBS-AA -52.5 W-39 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II or H- Shield Note 2 1 per 1.45 ft2 None SBS-SA- H (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -60.0 W-40 Min. 15/32-inch plywood, 24-inch span (Optional) Min. 1.5-inch, One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 None SBS-SA- H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -75.0 NEMO|etc. NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29 Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 11 of 74 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 3, Note 13) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply W-41 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.3 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA APP-TA -82.5 CONVENTIONAL SYSTEMS: W-42 Min. 23/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous) Note 2 1 per 2.0 ft2 None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -45.0* W-43 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -45.0* W-44 Min. 15/32-inch plywood, 24-inch span (Optional for Recover) Min. 1.5-inch, One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None APP-TA (Optional) APP- TA APP-TA -60.0 W-45 Min. 19/32-inch plywood, 24-inch span Min. 2-inch ACFoam II, ENRGY 3 or H-Shield, loose laid. Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -60.0 W-46 Min. 15/32-inch plywood, 24-inch span (Optional for Recover) Min. 1.5-inch, One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 None APP-TA (Optional) APP- TA APP-TA -67.5 NEMO|etc. NEMO ETC, LLC 7TH EDITION (2020) FBC NON-HVHZ EVALUATION (Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29 Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 30: 01/26/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 15 of 74 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasten (Note 11) Attach Base Ply Cap Ply W-70 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -75.0 W-71 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase Cap nails: 1-inch diameter, 0.032- inch metal cap with 0.120" shank diameter, annular ring shank nails 7-inch o.c. at min. 4-inch laps and 7-inch o.c. in five (5), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -75.0 W-72 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 4-inch o.c. at min. 2-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -105.0 HYBRID SYSTEMS: W-73 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -45.0* W-74 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Min. 1-inch long, 12 ga. Simplex Metal Cap Nails 6-inch o.c. at 3-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -52.5 W-75 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -52.5 W-76 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -60.0 W-77 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -82.5 W-78 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 4-inch o.c. at 3-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -105.0 CONVENTIONAL SYSTEMS: W-79 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0*