1921 Seminole Rd ROOF23-0081 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP:
MAHSHIE RICHARD 1513 Shaw Dr Key Largo FL 33037
COMPANY:ADDRESS:CITY:STATE:ZIP:
HOME SERVICES BY
MCCUE OF NORTH
FLORIDA
981 11TH AVE S Jacksonville S JACKSONVILLE
BEACH FL 32250
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
169542 0530 BEACHSIDE
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
1921 SEMINOLE RD ROOF NON SHINGLE Re-Roof Metal - Garage Only $4412.24
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL
Notes:
a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved. All roofing projects require an In-
Progress Inspection. Sheathing installation and replacement guidelines per APA. Underlayment must conform to FBC-R Table 905.1.1. Shingles must
conform to ASTM D3161 G or H, or ASTM D7158
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 11/7/2023
PERMIT NUMBER
ROOF23-0081
ISSUED: 11/7/2023
EXPIRES: 5/5/2024
ROOF NON SHINGLE PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
BUILDING PERMIT 455-0000-322-1000 0 $75.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $37.50
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL: $116.50
2 of 2Issued Date: 11/7/2023
PERMIT NUMBER
ROOF23-0081
ISSUED: 11/7/2023
EXPIRES: 5/5/2024
ROOF NON SHINGLE PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
Final Plumbing
Final Electrical
Final HVAC
CC Final
Final Building*
Swimming Pool Steel
Swimming Pool Safety
Electrical Grounding & Bonding
Swimming Pool Final (Bldg)
Swimming Pool Final (PW)
Formed Columns/ Beams*
Masonry Cell Fill
Structural Steel*
OTHER:
OTHER:
OTHER:
OTHER:
OTHER:
Power Pole
Silt Fence
Piers/ Stem Walls
Underground Plumbing
Underground Electric
Foundation/ Footing
Slab**
Retaining Wall Footing
Driveway
Sewer (Building Dept)
Sewer Tap (Utilities Dept)
Rough Electric*
Rough Plumbing/ Top Out*
Rough Mechanical*
House Wrap
Wall Sheathing
Roof Sheathing
Tie-down Framing Connections
Rough Framing
Roofing In Progress
Window/Door In-Progress
Insulation Ceiling
Insulation Wall
Exterior Lath
Stucco Scratch Coat
Exterior Siding In-Progress
Brick Flashing & Ties
Early Power
Gas Rough
Gas Final*
* When all rough electric, plumbing, mechanical are complete but before any work is
covered up.
* When all gas piping is complete and wallboard is installed but before gas is
attached to any appliance. All outlets must be capped and pipe pressurized at a
minimum of 15 lbs.
* For new living space: When all construction work including electrical, plumbing,
mechanical, exterior finish, grading, required paving and landscaping is complete
and the building is ready for occupancy, but before being occupied
Additional inspections may apply to your project if your project
contains these elements:
INSPECTIONS REQUIRED FOR BUILDING PERMITS
To verify compliance with building codes, inspections of the work authorized are required at various points of the construction.
The following inspections are typically required for residential projects:
Date: Initial: Date: Initial:
_____________________________________________________
Permit Type
____________________________________________________
Permit No.
__________________________________________________________
Job Address
____________________________________________________
Contractor
POST THIS CARD WITH PERMITS AND PERMIT
DOCUMENTATION IN FRONT OF BUILDING
Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends
Building Department Public Works/Utilities Fire Department
Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789
Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203
* When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all
electrical, plumbing and mechanical work is in place, but before concrete is poured.
* When all structural steel members are in place and all connections are complete,
but before such work is covered or concealed.
** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION
1921 SEMINOLE RD
Re-Roof Metal - Garage Only
HOME SERVICES BY MCCUE OF
NORTH FLORIDA
ROOF23-0081
ROOF23-0081
FL# 37331.1
Product Evaluation Report
TRI COUNTY METALS
Min. 26 Ga. TCM-Lok Roof Panel over 15/32” Plywood
Florida Product Approval # 37331.1
Florida Building Code 2020
Per Rule 61G20-3
Method: 1 –D
Category: Roofing
Subcategory: Metal Roofing
Compliance Method: 61G20-3.005(1)(d)
NON HVHZ
Product Manufacturer:
Tri County Metals
301 SE 16th Street
Trenton, Florida 32693
Engineer Evaluator:
Johnathan Green, P.E. # 88223
Florida Evaluation ANE ID: 1920
Validator:
Brian Jaks P.E. #70159
Contents:
Evaluation Report Pages 1 – 4
FL# 37331.1
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2020, Sections 1504.3.2.
Product Description: TCM-Lok Roof Panel, Min. 26 Ga. Steel, 16” coverage, over one layer of asphalt
shingles (optional) over min. 15/32” APA Plywood decking. Non-Structural
Application.
Panel Material/Standards: Material: Min. 26 Ga. Steel, conforming to Florida Building Code 2020 Section
1507.4.3. Paint finish optional.
Yield Strength: Min. 50.0 ksi
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2020, Section 1507.4.3.
Panel Dimension(s): Thickness: 0.019” Minimum
Width: 16” maximum coverage
Female Rib: 15/16” tall
Male Rib: 23/32” tall rib w/ slotted strip
Panel Seam: Snap Lock
Panel Fastener: Through Panel Slot: (1) #10-12x 1” Pancake Type A
¼” minimum penetration through plywood
Corrosion Resistance: Per Florida Building Code 2020, Section 1507.4.4.
Substrate Description: One layer of asphalt shingles/felt paper (optional) over min. 15/32” thick, APA
Rated plywood over supports at maximum 24” O.C. Design of plywood and
plywood supports are outside the scope of this evaluation. Substrate must be
designed in accordance w/ Florida Building Code.
Allowable Design Uplift Pressures:
Table "A"
Maximum Total Uplift Design Pressure: 52.5 psf
Fastener Spacing: 5 ¼” O.C.
*Design Pressure includes a Safety Factor = 2.0.
FL# 37331.1
Code Compliance: The product described herein has demonstrated compliance with
The Florida Building Code 2020, Section 1504.3.2.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2020, as relates to Rule 61G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
▪ UL 580-06 - Test for Uplift Resistance of Roof Assemblies
▪ UL 1897-2012 - Uplift Test for Roof Covering Systems
Reference Data: 1. UL 580-06 / 1897-04 Uplift Test
Force Engineering & Testing (FBC Organization # TST-5328)
Report No. 136-0087T-13
2. Certificate of Independence
By Johnathan Green, P.E. (No. 88223) @ Force Engineering & Testing (FBC
Organization # ANE ID: 1920)
Test Standard Equivalency: The UL 1897-04 test standard is equivalent to the UL 1897-2012 test standard.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2020, including Section
1507.4.2 and in accordance with Manufacturers recommendations. For slopes
less than 3:12, lap sealant must be used in the panel side laps.
Installation: Install per manufacturer’s recommended details.
Underlayment: Per Florida Building Code 2020, Section 1507.1 and manufacturer’s installation
guidelines.
FL# 37331.1
Roof Panel Fire Classification: Fire classification is not part of this acceptance.
Shear Diaphragm: Shear diaphragm values are outside the scope of this report.
Design Procedure: Based on the dimensions of the structure, appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2020 for roof cladding
wind loads. These component wind loads for roof cladding are compared to th e
allowable pressure listed above. The design professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover. Support framing must be in compliance with Florida Building Code 2020
Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading.
FL# 37331.1