Loading...
1921 Seminole Rd ROOF23-0081 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: MAHSHIE RICHARD 1513 Shaw Dr Key Largo FL 33037 COMPANY:ADDRESS:CITY:STATE:ZIP: HOME SERVICES BY MCCUE OF NORTH FLORIDA 981 11TH AVE S Jacksonville S JACKSONVILLE BEACH FL 32250 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169542 0530 BEACHSIDE JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1921 SEMINOLE RD ROOF NON SHINGLE Re-Roof Metal - Garage Only $4412.24 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved. All roofing projects require an In- Progress Inspection. Sheathing installation and replacement guidelines per APA. Underlayment must conform to FBC-R Table 905.1.1. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 11/7/2023 PERMIT NUMBER ROOF23-0081 ISSUED: 11/7/2023 EXPIRES: 5/5/2024 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 BUILDING PERMIT 455-0000-322-1000 0 $75.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $37.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $116.50 2 of 2Issued Date: 11/7/2023 PERMIT NUMBER ROOF23-0081 ISSUED: 11/7/2023 EXPIRES: 5/5/2024 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION 1921 SEMINOLE RD Re-Roof Metal - Garage Only HOME SERVICES BY MCCUE OF NORTH FLORIDA ROOF23-0081 ROOF23-0081 FL# 37331.1 Product Evaluation Report TRI COUNTY METALS Min. 26 Ga. TCM-Lok Roof Panel over 15/32” Plywood Florida Product Approval # 37331.1 Florida Building Code 2020 Per Rule 61G20-3 Method: 1 –D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Tri County Metals 301 SE 16th Street Trenton, Florida 32693 Engineer Evaluator: Johnathan Green, P.E. # 88223 Florida Evaluation ANE ID: 1920 Validator: Brian Jaks P.E. #70159 Contents: Evaluation Report Pages 1 – 4 FL# 37331.1 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2020, Sections 1504.3.2. Product Description: TCM-Lok Roof Panel, Min. 26 Ga. Steel, 16” coverage, over one layer of asphalt shingles (optional) over min. 15/32” APA Plywood decking. Non-Structural Application. Panel Material/Standards: Material: Min. 26 Ga. Steel, conforming to Florida Building Code 2020 Section 1507.4.3. Paint finish optional. Yield Strength: Min. 50.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2020, Section 1507.4.3. Panel Dimension(s): Thickness: 0.019” Minimum Width: 16” maximum coverage Female Rib: 15/16” tall Male Rib: 23/32” tall rib w/ slotted strip Panel Seam: Snap Lock Panel Fastener: Through Panel Slot: (1) #10-12x 1” Pancake Type A ¼” minimum penetration through plywood Corrosion Resistance: Per Florida Building Code 2020, Section 1507.4.4. Substrate Description: One layer of asphalt shingles/felt paper (optional) over min. 15/32” thick, APA Rated plywood over supports at maximum 24” O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Substrate must be designed in accordance w/ Florida Building Code. Allowable Design Uplift Pressures: Table "A" Maximum Total Uplift Design Pressure: 52.5 psf Fastener Spacing: 5 ¼” O.C. *Design Pressure includes a Safety Factor = 2.0. FL# 37331.1 Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2020, Section 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2020, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: ▪ UL 580-06 - Test for Uplift Resistance of Roof Assemblies ▪ UL 1897-2012 - Uplift Test for Roof Covering Systems Reference Data: 1. UL 580-06 / 1897-04 Uplift Test Force Engineering & Testing (FBC Organization # TST-5328) Report No. 136-0087T-13 2. Certificate of Independence By Johnathan Green, P.E. (No. 88223) @ Force Engineering & Testing (FBC Organization # ANE ID: 1920) Test Standard Equivalency: The UL 1897-04 test standard is equivalent to the UL 1897-2012 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2020, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per manufacturer’s recommended details. Underlayment: Per Florida Building Code 2020, Section 1507.1 and manufacturer’s installation guidelines. FL# 37331.1 Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2020 for roof cladding wind loads. These component wind loads for roof cladding are compared to th e allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2020 Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading. FL# 37331.1