Loading...
768 VECUNA RD SOLR23-0004 Adam McQuiston Solar Drawing Stamped Rev. 11-3-23PROJECT DATAGENERAL NOTESVICINITY MAPSHEET INDEXCODE REFERENCESPROJECTADDRESS768 VECUNA ROAD,ATLANTIC BEACH, FL 32233OWNER:ADAM MCQUISTONSCOPE:HOUSE PHOTOPHOTOVOLTAIC ROOF MOUNT SYSTEM36 MODULES-ROOF MOUNTED - 14.580 KW DC, 10.440 KW AC768 VECUNA ROAD, ATLANTIC BEACH, FL 32233DESIGNER:ESRREVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654G001COVER SHEETSIGNATURE1. ALL COMPONENTS ARE UL LISTED AND NEC CERTIFIED, WHERE WARRANTED.2. THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE NEC 2017.3. THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLELOPERATION.4. ALL CONDUCTORS OF A CIRCUIT, INCLUDING THE EGC, MUST BE INSTALLED IN THE SAME RACEWAY, OR CABLE, OROTHERWISE RUN WITH THE PV ARRAY CIRCUIT CONDUCTORS WHEN THEY LEAVE THE VICINITY OF THE PV ARRAY.5. WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS"CAUTION: SOLAR CIRCUIT" EVERY 10FT.6. HEIGHT OF THE AC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC CODE 240.24.7. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH NEC 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BEPROVIDED. PER NEC GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICEENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USEDAT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODECONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER AND BONDED TO THE EXISTINGGROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM.8. PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE.9. PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS.10. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE.WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF THE ROOF SURFACE.11. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH THE LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UVRESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ.12. INVERTER(S) USED IN UNGROUNDED SYSTEM SHALL BE UL 1741 LISTED.13. THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE PERFORMED ONLY BYQUALIFIED PERSONS [NEC 690.4(C)]14. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL ROOF MOUNTED TRANSITION BOXES ANDSWITCHES.15. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NEC ARTICLE 250.16. SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH NEC 690.41.17. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION IN ACCORDANCE WITHNEC 690.1218. DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE PV SYSTEMEQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [NEC 690.13(A)]19. ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.3120. WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC 110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3).21. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITHUL170322. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC.23. IN ACCORDANCE WITH 2021 IFC 1205.5, 2018 IFC 1204.4, AND 2015 IFC 605.11.2 A CLEAR, BRUSH-FREE AREA OF 10 FEET(3048MM) SHALL BE REQUIRED FOR GROUND-MOUNTED PHOTOVOLTAIC ARRAYS.24. PANEL LAYOUT ORIENTATION IS SUBJECT TO CHANGE ON DESIGNED MOUNTING PLANES.14.580 KW DC ROOF MOUNTSOLAR PV SYSTEM WITH36 MITREX SOLAR M405-I3H 405W PVMODULES WITH36 ENPHASE IQ8PLUS-72-2-USMICROINVERTERSPROJECT TO COMPLY WITH THE FOLLOWING:FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)FLORIDA PLUMBING CODE, 7TH EDITION 2020 (FPC)FLORIDA BUILDING CODE, 7TH EDITION 2020 EDITION (FBC)FLORIDA MECHANICAL CODE, 7TH EDITION 2020 (FMC)2017 NATIONAL ELECTRICAL CODEFLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020(FFPC)G001 COVER SHEETE001 SITE PLANS001 ROOF PLAN AND MODULESE002 ELECTRICAL PLANS002 STRUCTURAL DETAILE003 ELECTRICAL LINE DIAGRAME004 WIRING CALCULATIONSE005 LABELSE006 PLACARDPD001+ EQUIPMENT SPECIFICATIONSAUTHORITIES HAVING JURISDICTION:BUILDING: ATLANTIC BEACH CITYZONING: ATLANTIC BEACH CITYUTILITY: JEARI C HARD PANTELPROFESSIONAL ENG INEER L I CENSEFLORI DASTATE OFNo. 73222Reviewed and approvedRichard Pantel, P.E.FL Lic. No. 732229/15/2023This item has been digitally signed and sealed by Richard Pantel, P.E. on the date adjacent tothe seal. Printed copies of this document are not considered signed and sealed and thesignature must be verified on any electronic copies.By vangers at 3:06 pm, Nov 03, 2023Reviewed for codecomplianceCEP BU169911/06/2023 6:16:19 AMJOB COPY 102'-0"83'-0"103'-0"83'-0"UM TBACD MSP CB1SITE PLANSCALE: 1/16" = 1'-0"E001REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654PROJECT DESCRIPTION:SITE PLANNOTE: VISIBLE, LOCKABLE, LABELED AC DISCONNECTLOCATED WITHIN 10' OF UTILITY METER36 X MITREX SOLAR M405-I3H 405W MONO MODULESROOF MOUNTED SOLAR PHOTOVOLTAIC MODULESDC SYSTEM SIZE: 36 x 405 = 14.580KW DCAC SYSTEM SIZE: 36 x 290 = 10.440KW ACE001ROOF ARRAY AREA #1:- 62.97 SQ FT.ROOF ARRAY AREA #2:- 167.92 SQ FT.ROOF ARRAY AREA #3:- 230.89 SQ FT.ROOF ARRAY AREA #4:- 293.86 SQ FT.ROOF ARRAY AREA #1:- 62.97 SQ FT.ROOF ARRAY AREA #2:- 167.92 SQ FT.ROOF ARRAY AREA #3:- 230.89 SQ FT.ROOF ARRAY AREA #4:- 293.86 SQ FT.EQUIPMENT SUMMARY36 MITREX SOLAR M405-I3H 405W MONO MODULES36 ENPHASE IQ8PLUS-72-2-US MICROINVERTERSROOF #1(3) MITREX SOLAR M405-I3H 405WMONO MODULES WITH ENPHASEIQ8PLUS-72-2-US MICROINVERTERSROOF #2(8) MITREX SOLAR M405-I3H405W MONO MODULES WITH ENPHASEIQ8PLUS-72-2-US MICROINVERTERSROOF #3(11) MITREX SOLAR M405-I3H 405W MONO MODULES WITH ENPHASEIQ8PLUS-72-2-US MICROINVERTERSROOF #4(14) MITREX SOLAR M405-I3H405W MONO MODULES WITH ENPHASEIQ8PLUS-72-2-US MICROINVERTERS(N) ENPHASE COMBINER BOX(E) MAIN SERVICE PANEL(INSIDE)(N) VISIBLE, LOCKABLE,LABELED FUSED AC DISCONNECT(LOCATED WITHIN 10' OF UTILITY METER)(E) UTILITY METER(N) TAP BOX (INSTALLED WITHIN10' FROM THE UTILITY METERVECUNA ROADPROPERTY LINEPROPERTY LINE PROPERTY LINEPROPERTY LINE (E) POOLEXISTINGDRIVEWAY1-STORYHOUSEROOF ACCESS POINT(E) TREES(E) FENCE(E) GATE (TYP.)(E) DETACHED STRUCTURE (TYP.)RI C HARD PANTELPROFESSIONAL ENG INEER L I CENSEFLORI DASTATE OFNo. 73222Reviewed and approvedRichard Pantel, P.E.FL Lic. No. 732229/15/2023This item has been digitally signed and sealed by Richard Pantel, P.E. on the date adjacent tothe seal. Printed copies of this document are not considered signed and sealed and thesignature must be verified on any electronic copies.JOB COPY 3'-0"26'-3" 21'-9" 8'-4"11'-3"8'-6"10" 6" 1'-3"1'-2"4'-0"MSP MODULE TYPE, DIMENSIONS & WEIGHTSCALE: 3/32" = 1'-0"ROOF PLAN ANDMODULESNUMBER OF MODULES = 36 MODULESMODULE TYPE = MITREX SOLAR M405-I3H 405W MONO MODULESMODULE WEIGHT = 45.2 LBS / 20.5KG.MODULE DIMENSIONS = 67.8" x 44.6" = 20.99 SFMITREX SOLARM405-I3H 405WMODULES67.8"44.6"S001REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654ARRAY AREA & ROOF AREA CALC'STOTAL PV ARRAYAREA(SQ. FT.)TOTAL ROOFAREA(Sq. Ft.)ROOFAREA COVERED BYARRAY (%)755.642515.7330ROOF DESCRIPTIONROOF TYPEASPHALT SHINGLEROOF# OFMODULESROOFPITCHAZIMUTHTRUSSSIZETRUSSSPACING#1317°275°2"X4" 24"#2 817°185°2"X4" 24"#3 11 17°275°2"X4" 24"#4 14 17°95°2"X4" 24"1ROOF PLAN AND MODULESS001MSP- MAIN SERVICE PANEL- VENT, ATTIC FAN(ROOF OBSTRUCTION)- ROOF ATTACHMENT- TRUSSLEGEND(E) MAIN SERVICE PANEL(INSIDE)ROOF #1(3) MITREX SOLAR M405-I3H 405WMONO MODULES WITH ENPHASEIQ8PLUS-72-2-US MICROINVERTERSROOF #1PITCH - 17°AZIM. - 275°ROOF #2(8) MITREX SOLAR M405-I3H405W MONO MODULES WITH ENPHASEIQ8PLUS-72-2-US MICROINVERTERSROOF #2PITCH - 17°AZIM. - 185°ROOF #3(11) MITREX SOLAR M405-I3H 405W MONO MODULES WITH ENPHASEIQ8PLUS-72-2-US MICROINVERTERSROOF #3PITCH - 17°AZIM. - 275°ROOF #4(14) MITREX SOLAR M405-I3H405W MONO MODULES WITH ENPHASEIQ8PLUS-72-2-US MICROINVERTERSROOF #4PITCH - 17°AZIM. - 95°ACTUAL MAXIMUM CANTILEVER ALLOWED = L/3,WHERE L IS THE ATTACHMENT SPACINGATTACHMENT SPACING, L = 48"ACTUAL MAXIMUM CANTILEVER ALLOWED = 48/3ACTUAL MAXIMUM CANTILEVER ALLOWED = 16",i.e, 1'-4"CANTILEVER LENGTH 10"CANTILEVER LENGTH 1'-2''CANTILEVER LENGTH 6"CANTILEVER LENGTH 1'-3''ROOF ACCESS POINT(N) EVEREST K2 SYSTEMSCROSSRAIL 44-X RAIL(86) EVEREST K2 SYSTEMS SPLICE FOOT XLATTACHMENTS18" FIRE SETBACK18" FIRE SETBACK18" FIRE SETBACK18" FIRE SETBACK 18" FIRE SETBACK18" FIRE SETBACK1 8 " F I R E S E T B A C K 1 8 " F I R E S E T B A C K 36" FIRE SETBACK18" FIRE SETBACK 18" FIRE SETBACK 36" FIRE SETBACK36" FIRE SETBACK18" FIRE SETBACK 18" FIRE SETBACK RI C HARD PANTELPROFESSIONAL ENG INEER L I CENSEFLORI DASTATE OFNo. 73222Reviewed and approvedRichard Pantel, P.E.FL Lic. No. 732229/15/2023This item has been digitally signed and sealed by Richard Pantel, P.E. on the date adjacent tothe seal. Printed copies of this document are not considered signed and sealed and thesignature must be verified on any electronic copies.JOB COPY UM TBACDMSPCB SDSDSDSDSCALE: 1/8" = 1'-0"ELECTRICAL PLANREVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654E002BILL OF MATERIALSEQUIPMENTQTYDESCRIPTIONSOLAR PV MODULES36MITREX SOLAR M405-I3H 405W MODULEMICRO INVERTERS36ENPHASE IQ8PLUS-72-2-US MICROINVERTERSSOLADECK4 SOLADECKSRAIL20EVEREST K2 SYSTEMS CROSSRAIL 44-X RAILSPLICES8SPLICESMID MODULE CLAMPS56MID MODULE CLAMPSEND CLAMPS32END CLAMPS / STOPPER SLEEVEATTACHMENTS86EVEREST K2 SYSTEMS SPLICE FOOT XLATTACHMENTSCIRCUIT #1CIRCUIT #2CIRCUIT #3CIRCUIT LEGENDSUMMSP- UTILITY METER- MAIN SERVICE PANEL- VENT, ATTIC FAN(ROOF OBSTRUCTION)- ROOF ATTACHMENT- CONDUITACD- AC DISCONNECTLEGEND- COMBINER BOXCBTB- TAP BOX- SOLADECKSD- TRUSS1ELECTRICAL PLANE002NOTE : CONDUIT INSTALLED ATMINIMUM DISTANCE OF 7/8 INCHESABOVE ROOF(N) ENPHASE COMBINER BOX(E) MAIN SERVICE PANEL(INSIDE)(N) VISIBLE, LOCKABLE,LABELED FUSED AC DISCONNECT(LOCATED WITHIN 10' OF UTILITY METER)(E) UTILITY METER(N) TAP BOX (INSTALLED WITHIN10' FROM THE UTILITY METERCIRCUIT #1(12 MODULES)CIRCUIT #2(12 MODULES)CIRCUIT #3(12 MODULES)(36) ENPHASEIQ8PLUS-72-2-US MICROINVERTERSLOCATED UNDER EACH PANEL (240V)VECUNA ROAD(N) CONDUIT(N) SOLADECK (TYP.)RI C HARD PANTELPROFESSIONAL ENG INEER L I CENSEFLORI DASTATE OFNo. 73222Reviewed and approvedRichard Pantel, P.E.FL Lic. No. 732229/15/2023This item has been digitally signed and sealed by Richard Pantel, P.E. on the date adjacent tothe seal. Printed copies of this document are not considered signed and sealed and thesignature must be verified on any electronic copies.JOB COPY REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654STRUCTURAL DETAILS0022ATTACHMENT DETAIL (ENLARGED VIEW)S0021ATTACHMENT DETAIL (SIDE VIEW)S002SCALE: N.T.S.SCALE: N.T.S.SEE (2/S002) FORENLARGED VIEWPV MODULE(E) ASPHALT SHINGLE ROOF2"X4" TRUSS @ 24" O .C .6"CHANNEL NUTPV MODULEGROUNDINGEND/MID CLAMPEVEREST K2 SYSTEMSCROSSRAIL 44-X RAIL(E) ASPHALT SHINGLE ROOF2"X4" TRUSS @ 24" O.C.M5 X 60MM DIN 571, METRIC, HEXHEAD LAG SCREW BOLTS, A2STAINLESS STEEL WITH MIN. 2"PENETRATION INTO SUPPORT(N) EVEREST K2 SYSTEMSSPLICE FOOT XL ATTACHMENTS(E) ROOF DECKING(E) ROOF DECKINGRI C HARD PANTELPROFESSIONAL ENG INEER L I CENSEFLORI DASTATE OFNo. 73222Reviewed and approvedRichard Pantel, P.E.FL Lic. No. 732229/15/2023This item has been digitally signed and sealed by Richard Pantel, P.E. on the date adjacent tothe seal. Printed copies of this document are not considered signed and sealed and thesignature must be verified on any electronic copies.JOB COPY LOADLINEGL1L2NG3NVISIBLE, LOCKABLE,LABELED AC DISCONNECTLOCATED WITHIN 10'OF UTILITY METER60AFusesPV FUSED ACDISCONNECT240V, 1ɸ, 3W60A RATEDNEMA 3RLINE SIDEINTERCONNECTIONAT MAIN PANELPER ART. 705.12L1L2NL2L1MTO UTILITY GRID4NGECNNBI-DIRECTIONALUTILITY METER120/240V, 1ɸ, 3-WEXISTING GROUNDINGELECTRODE SYSTEM TOEARTH REF. NEC 250.52,250.53(A)SUPPLY SIDE CONNECTION INSIDENEWLY INSTALLED TAP BOXREF 2017 NEC 230.82(6)/705.12(A)(E) MAIN SERVICEPANEL,SQUARE D 200A RATED, 240V(N) #6 BARE CU VIAIRREVERSIBLE CRIMP TOEXISTING GROUNDINGELECTRODE SYSTEM(N) TAP BOXNEMA 3R TYPEENCLOSURE(E) MAIN BREAKER TOHOUSE 240 V, 200A/2PEEGG#4 AWG CU, MAINBONDING JUMPERPER NEC 250.8 &250.28(E) BONDING JUMPERPER NEC 250.92(A)(2)L1L2G- + - +2- +13=12====BRANCHTERMINATOR(ET-TERM)GN- + - +2- +13=====- + - +2- +13=====SOLADECK,600V, NEMA 3R,UL LISTEDBRANCH #1BRANCH #2BRANCH #3L2L2L1L2L120A/2P20A/2P20A/2P11 1211 1211 1215A/2P(36) MITREX SOLAR M405-I3H405W MODULESENPHASE IQ8PLUS-72-2-USMICROINVERTERSLOCATED UNDER EACH PANEL (240V)IQGATEWAYECALLOUT STANDS FOR EXISTING CONDUCTORSENPHASE IQ COMBINERX-IQ-AM1-240-4/4C 120/240VAC,1ɸ, 3W 125A RATED BUS BAR,NEMA 3R SOLAR LOADS ONLYUL 1741 COMPLIANTREVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654ELECTRICAL LINE DIAGRAMSCALE: NTSE003DC SYSTEM SIZE: 36 x 405 = 14.580KW DCAC SYSTEM SIZE: 36 x 290 = 10.440KW AC(36) MITREX SOLAR M405-I3H 405W MONO MODULESWITH (36) ENPHASE IQ8PLUS-72-2-US MICROINVERTERSLOCATED UNDER EACH PANEL (240V)(3) BRANCH CIRCUITS OF 12 MODULES ARE CONNECTED IN PARALLEL1ELECTRICAL LINE DIAGRAME003INTERCONNECTION NOTES:1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCEDETERMINED IN ACCORDANCE WITH [NEC 705.12], AND [NEC 690.59].2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9],[NEC 230.95].3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING.4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THEBUSBAR RELATIVE TO THE MAIN BREAKER.DISCONNECT NOTES:1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHENTHE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARECONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLYTHE UPPER TERMINALS)2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITYPERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH3. DISCONNECT MEANS AND THEIR LOCATION SHALL BE INACCORDANCE WITH [NEC 225.31] AND [NEC 225.32].GROUNDING & GENERAL NOTES:1. PV GROUNDING ELECTRODE SYSTEM NEEDS TO BE INSTALLED IN ACCORDANCEWITH [NEC 690.43]2. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE.3. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTINGELECTRODE4. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT ISFOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINALINSPECTION.5. SOLADECK QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THEFIELD - SOLADECKS DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRETYPE TRANSITIONS.6. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHERAC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT.7. RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS SHOULD BEINSTALLED MORE THAN 7/8" ABOVE THE ROOF USING CONDUIT SUPPORTS.RACKING NOTE:1. BOND EVERY OTHER RAIL WITH #6 BARE COPPERQTYCONDUCTOR INFORMATIONCONDUIT TYPECONDUITSIZE(6)CU#12AWG -ENPHASE ENGAGE CABLE(L1 & L2 NO NEUTRAL)N/AN/A(1)(6)CU#10AWG -ENT OR LFMC IN ATTIC3/4"(1)CU,THWN-2 GND(2)EMT, LFMC OR PVC(1)CU,THWN-2 OR THHN N(1)CU,THWN-2 OR THHN GND(2)EMT, LFMC OR PVC(1)CU,THWN-2 OR THHN N12343/4"3/4"THWN-2 OR THHN L1 &L2THWN-2 OR THHN L1 &L2THWN-2 L1 &L2CU #10AWG -CU #6AWG -CU #6AWG -CU #10AWG -CU #6AWG -CU #6AWG -CU #6AWG - BARE COPPER IN FREE AIR#12/2 ROMEX INATTICNOTE : "CONDUIT SIZE IS MINIMUM REQUIRED PER NEC300.17. CONTRACTOR MAY UPSIZE AS NEEDED".OCPD CONDUCTOR SIZEBREAKER/FUSE SIZEWIRE GAUGE SIZE (75°C,COPPER)20A10 AWG25A10 AWG30A10 AWG35A8 AWG40A8 AWG45A8 AWG50A8 AWG60A6 AWG70A4 AWG80A4 AWG90A3 AWG100A3 AWG110A2 AWG125A1 AWG150A1/0 AWG175A2/0 AWG200A3/0 AWGRI C HARD PANTELPROFESSIONAL ENG INEER L I CENSEFLORI DASTATE OFNo. 73222Reviewed and approvedRichard Pantel, P.E.FL Lic. No. 732229/15/2023This item has been digitally signed and sealed by Richard Pantel, P.E. on the date adjacent tothe seal. Printed copies of this document are not considered signed and sealed and thesignature must be verified on any electronic copies.JOB COPY REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654WIRING CALCULATIONSE004PERCENT OFVALUESNUMBER OF CURRENTCARRYING CONDUCTORS IN EMT.804-6.707-9.5010-20SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL # MITREX SOLAR M405-I3H 405W MODULE VMP31.11V IMP13.02A VOC37.55V ISC13.73A TEMP. COEFF. VOC-0.26%/°C MODULE DIMENSION67.8"L x 44.6"W x 1.2"D (In Inch)AMBIENT TEMPERATURE SPECSRECORD LOW TEMP-4°AMBIENT TEMP (HIGH TEMP 2%)36°MODULE TEMPERATURE COEFFICIENT OF Voc-0.26%/°CELECTRICAL NOTES1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION.2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT.3. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSEAS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.4. WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.5. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARYOUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS.6. WHERE SIZES OF SOLADECKS, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEMACCORDINGLY.7. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE.8. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THEGROUNDING CLIP MANUFACTURER'S INSTRUCTION.9. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.10. TEMPERATURE RATINGS OF ALL CONDUCTORS, TERMINATIONS, BREAKERS, OR OTHER DEVICES ASSOCIATED WITH THESOLAR PV SYSTEM SHALL BE RATED FOR AT LEAST 75 DEGREE C.11. CONDUIT INSTALLED AT MINIMUM DISTANCE OF 7/8 INCHES ABOVE ROOF .....NEC 310.15(B)(3)(C)INVERTER SPECIFICATIONSMANUFACTURER / MODEL #ENPHASE IQ8PLUS-72-2-US MICROINVERTERSMIN/MAX DC VOLT RATING 30V MIN/ 58V MAXMAX INPUT POWER235W-440WNOMINAL AC VOLTAGE RATING 240V/ 211-264VMAX AC CURRENT1.21AMAX MODULES PER CIRCUIT13 (SINGLE PHASE)MAX OUTPUT POWER290 VARI C HARD PANTELPROFESSIONAL ENG INEER L I CENSEFLORI DASTATE OFNo. 73222Reviewed and approvedRichard Pantel, P.E.FL Lic. No. 732229/15/2023This item has been digitally signed and sealed by Richard Pantel, P.E. on the date adjacent tothe seal. Printed copies of this document are not considered signed and sealed and thesignature must be verified on any electronic copies.JOB COPY REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654LABELSE005LABEL-1:CAUTION:AUTHORIZED SOLARPERSONNEL ONLY!LABEL LOCATION:AC DISCONNECTWARNING!TERMINALS ON THE LINE AND LOAD SIDES MAYBE ENERGIZED IN THE OPEN POSITIONELECTRICAL SHOCK HAZARDLABEL LOCATION:AC DISCONNECTCOMBINERMAIN SERVICE PANELSUBPANELMAIN SERVICE DISCONNECTCODE REF: NEC 690.13(B)LABEL- 2:!WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMLABEL LOCATION:UTILITY METERMAIN SERVICE PANELSUBPANELCODE REF: NEC 705.12(C) & NEC 690.59LABEL- 3:TURN OFF PHOTOVOLTAIC ACDISCONNECT PRIOR TOWORKING INSIDE PANELWARNING!LABEL LOCATION:MAIN SERVICE PANELSUBPANELMAIN SERVICE DISCONNECTCOMBINERCODE REF: NEC 110.27(C) & OSHA 1910.145 (f) (7)LABEL- 4:LABEL LOCATION:MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK-FED)SUBPANEL (ONLY IF SOLAR IS BACK-FED)CODE REF: NEC 705.12(B)(3-4) & NEC 690.59LABEL- 5:CAUTION!PHOTOVOLTAIC SYSTEM CIRCUIT ISBACKFEEDLABEL LOCATION:MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK-FED)SUBPANEL (ONLY IF SOLAR IS BACK-FED)CODE REF: NEC 705.12(B)(3)(2)LABEL- 6:SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR ELECTRICPV PANELSRAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEMLABEL LOCATION:AC DISCONNECTCODE REF: NEC 690.56(C)(2)LABEL- 8:PHOTOVOLTAICAC DISCONNECTLABEL LOCATION:AC DISCONNECTCODE REF: NEC 690.13(B)LABEL- 9:LABEL- 10:LABEL LOCATION:MAIN SERVICE PANELSUBPANELAC DISCONNECTCODE REF: NEC 690.54RATED AC OUTPUT CURRENTPHOTOVOLTAICAC DISCONNECTNOMINAL OPERATING AC VOLATGE240 VWARNING!POWER SOURCE OUTPUTCONNECTION. DO NOTRELOCATE THISOVERCURRENT DEVICEMAIN PHOTOVOLTAICSYSTEM DISCONNECTLABEL LOCATION:MAIN SERVICE DISCONNECT (ONLY IF MAIN SERVICE DISCONNECT IS PRESENT)CODE REF: NEC 690.13(B)LABEL- 11:43.56 ALABEL LOCATION:AC DISCONNECTCODE REF: FFPC 11.12.1.1.1.1 & NEC 690.56(C)THE LABEL SHALL BE REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND HAVINGA MINIMUM HEIGHT OF 3/8 IN. (9.5 MM), IN WHITE ON A RED BACKGROUND.TURN RAPID SHUTDOWNSWITCH TO THE 'OFF'POSITION TO SHUTDOWNENTIRE PV SYSTEMEMERGENCY RESPONDER:THIS SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRIC PV PANELSLABEL LOCATION:AC DISCONNECTCODE REF:NFPA 1 (11.12.2.1.1.1.1)1. THE RAPID SHUTDOWN LABEL SHALL BE LOCATED ON OR NO MORETHAN 3 FT (1 M) FROM THE SERVICE DISCONNECTING MEANS2. (HEIGHT OF LABEL IS 3/8 IN. (9.5 MM), IN WHITE ON A RED BACKGROUND)LABEL- 12:EMERGENCY CONTACTSUNERGY SOLAR LLC(727) 375-9375LABEL- 14LABEL LOCATION:MAIN SERVICE DISCONNECTCODE REF: NFPA 1 (11.12.2.1.5)NOTES:1.THE MATERIAL USED FOR THE PHOTOVOLTAIC SYSTEM LABELS SHALL BEREFLECTIVE, WEATHER RESISTANT, AND CONSTRUCTED OF DURABLE ADHESIVEMATERIAL OR ANOTHER APPROVED MATERIAL SUITABLE FOR THE ENVIRONMENTIN COMPLIANCE WITH NFPA 1-11.12.2. FONT, TEXT HEIGHT , CAPITALIZATION , FONT COLOR(S), BACKGROUNDCOLOR(S), DIAGRAM COLOR(S)AND CONTEXT OF PHOTOVOLTAIC SYSTEMS LABELSSHALL COMPLY WITH NFPA 1-11.12 AND NEC 2017 690.56 AS APPLICABLE FORTHE PHOTOVOLTAIC SYSTEM TO BE INSTALLED.LABEL LOCATION:MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK-FED)SUBPANEL (ONLY IF SOLAR IS BACK-FED)CODE REF: NEC 705.12(B)(3)(2)LABEL- 7:WARNING!THIS EQUIPMENT FED BYMULTIPLE SOURCES. TOTALRATING OF ALL OVERCURRENTDEVICES EXCLUDING MAINSUPPLY OVERCURRENT DEVICESHALL NOT EXCEED AMPACITYOF BUSBAR.LABEL- 13RI C HARD PANTELPROFESSIONAL ENG INEER L I CENSEFLORI DASTATE OFNo. 73222Reviewed and approvedRichard Pantel, P.E.FL Lic. No. 732229/15/2023This item has been digitally signed and sealed by Richard Pantel, P.E. on the date adjacent tothe seal. Printed copies of this document are not considered signed and sealed and thesignature must be verified on any electronic copies.JOB COPY UM TBACD MSP CB SDSDSDSD REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654PLACARDE006LABELING NOTES:1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACTREQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS.2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535.3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION.4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21]5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLYAFFIXED FFPC 11.12.2.1.1.2POWER TO THIS BUILDING IS ALSO SUPPLIED FROM MULTIPLESOURCES OF POWER WITH SAFETY DISCONNECTS AS SHOWN:CAUTION768 VECUNA ROAD, ATLANTIC BEACH, FL 32233DIRECTORYPERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THESERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM.(ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN:NEC 690.56(B)&(C), [NEC 705.10])PER FFPC 11.12.2.1.4(N) SOLADECK (TYP.)(N) PV ARRAY(N) ENPHASE COMBINERBOX(N) PV AC DISCONNECT(E) MAIN SERVICE PANEL(INSIDE)(E) UTILITY METER(N) TAP BOXRI C HARD PANTELPROFESSIONAL ENG INEER L I CENSEFLORI DASTATE OFNo. 73222Reviewed and approvedRichard Pantel, P.E.FL Lic. No. 732229/15/2023This item has been digitally signed and sealed by Richard Pantel, P.E. on the date adjacent tothe seal. Printed copies of this document are not considered signed and sealed and thesignature must be verified on any electronic copies.JOB COPY REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654MODULEDATASHEETPD001RI C HARD PANTELPROFESSIONAL ENG INEER L I CENSEFLORI DASTATE OFNo. 73222Reviewed and approvedRichard Pantel, P.E.FL Lic. No. 732229/15/2023This item has been digitally signed and sealed by Richard Pantel, P.E. on the date adjacent tothe seal. Printed copies of this document are not considered signed and sealed and thesignature must be verified on any electronic copies.JOB COPY REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654MICROINVERTERDATASHEETPD002RI C HARD PANTELPROFESSIONAL ENG INEER L I CENSEFLORI DASTATE OFNo. 73222Reviewed and approvedRichard Pantel, P.E.FL Lic. No. 732229/15/2023This item has been digitally signed and sealed by Richard Pantel, P.E. on the date adjacent tothe seal. Printed copies of this document are not considered signed and sealed and thesignature must be verified on any electronic copies.JOB COPY REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654COMBINER BOXDATASHEETPD003RI C HARD PANTELPROFESSIONAL ENG INEER L I CENSEFLORI DASTATE OFNo. 73222Reviewed and approvedRichard Pantel, P.E.FL Lic. No. 732229/15/2023This item has been digitally signed and sealed by Richard Pantel, P.E. on the date adjacent tothe seal. Printed copies of this document are not considered signed and sealed and thesignature must be verified on any electronic copies.JOB COPY REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654ATTACHMENTDATASHEETPD004RI C HARD PANTELPROFESSIONAL ENG INEER L I CENSEFLORI DASTATE OFNo. 73222Reviewed and approvedRichard Pantel, P.E.FL Lic. No. 732229/15/2023This item has been digitally signed and sealed by Richard Pantel, P.E. on the date adjacent tothe seal. Printed copies of this document are not considered signed and sealed and thesignature must be verified on any electronic copies.JOB COPY REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654DATASHEETPD005RACKINGRI C HARD PANTELPROFESSIONAL ENG INEER L I CENSEFLORI DASTATE OFNo. 73222Reviewed and approvedRichard Pantel, P.E.FL Lic. No. 732229/15/2023This item has been digitally signed and sealed by Richard Pantel, P.E. on the date adjacent tothe seal. Printed copies of this document are not considered signed and sealed and thesignature must be verified on any electronic copies.JOB COPY REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654SOLADECKDATASHEETPD006RI C HARD PANTELPROFESSIONAL ENG INEER L I CENSEFLORI DASTATE OFNo. 73222Reviewed and approvedRichard Pantel, P.E.FL Lic. No. 732229/15/2023This item has been digitally signed and sealed by Richard Pantel, P.E. on the date adjacent tothe seal. Printed copies of this document are not considered signed and sealed and thesignature must be verified on any electronic copies.JOB COPY