Loading...
2332 BAREFOOT TR FOUN23-0013 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: O PEZIO ROBERT J 2332 BAREFOOT TRCE ATLANTIC BEACH FL 32233-6603 COMPANY:ADDRESS:CITY:STATE:ZIP: Solid Foundation Solutions, LLC 2704 SW Main Blvd Lake City FL 32025 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169463 0608 OCEANWALK UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 2332 BAREFOOT TRACE FOUNDATION ONLY SINGLE OR TWO FAMILY FOUNDATION ONLY FOUNDATION REPAIR - HELICAL PILES $5700.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $80.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $40.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 11/13/2023 PERMIT NUMBER FOUN23-0013 ISSUED: 11/13/2023 EXPIRES: 5/11/2024 FOUNDATION ONLY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 TOTAL: $124.00 2 of 2Issued Date: 11/13/2023 PERMIT NUMBER FOUN23-0013 ISSUED: 11/13/2023 EXPIRES: 5/11/2024 FOUNDATION ONLY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $124.00 FOUN23-0013 Address: 2332 BAREFOOT TRACE APN: 169463 0608 $124.00 BUILDING $80.00 BUILDING PERMIT 455-0000-322-1000 0 $80.00 BUILDING PLAN REVIEW $40.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $40.00 STATE SURCHARGES $4.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R25472 $124.00 Printed: Monday, November 13, 2023 1:30 PM Date Paid: Monday, November 13, 2023 Paid By: Solid Foundation Solutions, LLC Pay Method: CREDIT CARD 10115996627 1 of 1 Cashier: TG Cash Register Receipt City of Atlantic Beach Receipt Number R25472 FOUN23-0013 By Mike Jones at 2:31 pm, Nov 06, 2023REVIEWED FOR CODE COMPLIANCE FOUN23-0013 FOUN23-0013 Cool and Cobb Engineering Company __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ 203 W. Main St. Avon Park, FL 33825 Office: (863) 657-2323 Fax: (863) 657-2324 Contractor: Solid Foundations Date: 10/31/2023 Project: 23-1415 Job: Robert O’Pezio Location: 2332 Barefoot Ter., Atlantic Beach, Fl. 32233 PILING DESIGN ANALYSIS The load requirements for the pilings designed to assist in supporting the identified areas of the subject residence were determined. The selected piling locations and the specific piling are identified on the Pier Identification and Location Plan attached. The calculated total loads on the piles in the specific location, including both dead and live loads are documented in the attached table which is designated as Attachment “A”. Based on the total load requirements for each of these piles, the 12ALS driver is to be employed. The 12ALS torque driver should be employed with a selected gauge pressure of 1,000 psi, which will provide pile capacity, including the 2 to 1 safety factor of 37,330 lbs. which is greater than the maximum calculated total load of 12,000_ lbs. which occurs on the pile identified as no. 1 . Based on this analysis, the use of the 12ALS torque driver for the piles with a specific gauge pressure of 1,000 psi and a minimum depth of 10’ is approved and certified as meeting all the requirements of the Florida Building Code 2020 7th Edition, and good engineering practice. This is not to be the primary support structure, but a supplement support to assist in support of the weight of the structure, which will reduce the total pressure on the existing soils. After completion of installation, Cool and Cobb Engineering Company shall be supplied with a drilling log of the location and depths of each pile installed so they can evaluate the installation and prepare the “As Built” drawings. General Notes: 1. All piles to be installed in accordance with ICC ES AC 358 2. A log of each pile to be kept by Contractor noting depth and final torque installed for each pile. 3. Minimum pile depth to be 10’-0”. 4. All pile calculations are based on a maximum spacing of 8’-0”. 5. Helical piles installed less than 48” apart are to be battered 10° away from each other. 6. This design is based on the loads of the structure placed on the shallow soils under the structure. 7. No deep soils geotechnical testing information was provided for this design. 8. This design does not address any possible sink hole activity as defined in Florida Statute § 627.706. 10/31/2023 Kenneth F. Wheeler, P.E. State of Florida Professional Engineer No. 60417 By Mike Jones at 2:34 pm, Nov 06, 2023 Solid Foundations SF Representative:Jimbo Willis Cell:386-288-3240 Email:Jimmie@solidfoundations.com CONTRACT DATE:EMAIL: SUBMITTED TO:Phone: ADDRESS: R&R Concrete NCFI-24-010 Windows/Doors: Floor Joist: Push Pier Model 250: Helical Pier: Robert O'Pezio 2332 Barefoot Ter. 904-655-4192 Crawl Space Pier: Lake City, FL 32025 855-227-0300 www.solidfoundations.com Push Pier Model 300: 1910 SW Main Blvd 4x6 Wood Beam: Interior Pier: Low Profile Bracket: Porch Bracket: opzo@comcast.net10/23/2023 STABILIZE ONLY 1-story home on a stemwall foundation with stucco siding 1 2 3 4 10/31/2023 Kenneth F. Wheeler, P.E.PE #60417Cool and Cobb Engineering Co.203 W. Main St. Avon Park, FL 33825 Date: Job: Location: PILE NO. 1 12,000 lbs 2 12,000 lbs 3 12,000 lbs 4 12,000 lbs 12,000.00 lbs Cool and Cobb Engineering Co. 203 W. Main St. Avon Park, FL 33825Kenneth F Wheeler, P.E. PE# 60417 Cool and Cobb Engineering Company 10/31/2023 10/31/2023 Robert O'Pezio 2332 Barefoot Ter., Atlantic Beach, Fl. 32233 Attachment "A" Total Load on Pile (Live Load + Dead Load) TOTAL CALCULATE LOAD Maximum Total Load on Pile: Digga North America - info@diggausa.com - www.diggausa.com - P: 563-875-7915 C: 563-845-9177 PLANETARY ANCHOR DRIVES9,000 FT LBS - 12,000 FT LBS PREMIUM ANCHOR DRIVES FEATURES • High efficiency EATON/DIGGA bell geroler hydraulic motors with integrated Pressure Relief Valve ensures max volumetric effeciency for consistent & efficient pile installation throughout your working day • More linear feet in the ground = greater returns • ECV (Energy Control Valve) to prevent rapid decompression of oil, caused by the reverse energy created by Pile Kick-back • Engineered hood & ears for maximum strength • Extreme duty shaft retaining system • No Case Drain required • 3yr Gearbox & 2yr Motor Warranty Developed in conjunction with the leading Screw Anchor/Pile installers around the world. The only true Anchor Drives available, de- signed & manufactured inhouse by Digga, specifically for the rigours of the application. Host machine operates in the most efficient HP range, minimizing wear & tear, to optimize performance & ensure highest returns. Need Torque from a lower pressure? No problem. Two pressure series are available to suit your requirements.Standard pressure series, for machines with 3500 PSI. Low Pressure series, for machines with 3000 PSI GEARBOX WARRANTY 3 YEAR MOTOR WARRANTY 2 YEAR STANDARD PRESSURE - 3500 PSI MODEL 9ADS 12ADS Nominal Torque (FT LBS)9,112 11,542 Max Pressure - Do Not Exceed 3500psi @ 29gpm 3500psi @ 29gpm Max Flow - Do Not Exceed 55gpm @ 1800psi 55gpm @ 1800psi Max Horse Power 60 60 Pressure Relief Valve Included Included Energy Control Valve Included Included Standard Output Shaft 2.5” Hex 2.5” Hex Weight (lbs)351 351 Overall Length (in)37.2”37.2” Diameter (in)11.4”11.4” LOW PRESSURE - 3000 PSI 9ALS 12ALS 9,893 12,445 3000psi @ 29gpm 3000psi @ 29gpm 55gpm @ 1800psi 55gpm @ 1800psi 60 60 Included Included Included Included 2.5” Hex 2.5” Hex 351 351 37.2”37.2” 11.4”11.4” •Ryno Piling cradle •Drive Linkages •Excavator Mounts/Hitch •Diggalign - Pile/Auger Alignment system •Torque Monitoring - Pressure Differential Guage •Torque Logic - Pile Alignment / Data Logging system OPTIONALEXTRAS 10/31/2023 Kenneth F. Wheeler, P.E.PE #60417Cool and Cobb Engineering Co. 203 W. Main St.Avon Park, FL 33825 Digga North America - info@diggausa.com - www.diggausa.com - P: 563-875-7915 C: 563-845-9177 Output speed and torque specifications are THEORETICAL. Speed and torque output are dependent on the overall system efficiencies associated with the prime movers hydraulic system. This document should be used for information and comparative purposes only. When determining criteria, & application specific information is required, please contact DIGGA. PLANETARY ANCHOR DRIVES9,000 FT LBS - 12,000 FT LBS 9ADS - STANDARD PRESSURE - 3500 PSI OUTPUT SPEED OUTPUT TORQUE GPM RPM PSI FT-LBS 8 9 1,500 3,905 10 12 1,700 4,425 12 14 1,900 4,945 14 16 2,100 5,465 16 19 2,300 5,990 18 21 2,500 6,510 20 24 2,700 7,030 24 26 2,900 7,550 26 28 3,200 8,070 28 31 3,300 8,590 30 33 3,500 9,100 32 38 34 40 36 42 38 45 40 47 42 49 44 52 46 54 12ADS - STANDARD PRESSURE - 3500 PSI OUTPUT SPEED OUTPUT TORQUE GPM RPM PSI FT-LBS 8 7 1,500 4,945 10 9 1,700 5,605 12 11 1,900 6,265 14 13 2,100 6,925 16 15 2,300 7,585 18 17 2,500 8,245 20 19 2,700 8,905 24 20 2,900 9,565 26 22 3,200 10,225 28 24 3,300 10,880 30 26 3,500 11,500 32 30 34 32 36 33 38 35 40 37 42 39 44 41 46 43 OUTPUT SPEED & TORQUE 9ALS - LOW PRESSURE - 3000 PSI OUTPUT SPEED OUTPUT TORQUE GPM RPM PSI FT-LBS 8 7 1 000 3 298 12 11 1 200 3 957 16 15 1 400 4 617 20 19 1 600 5 276 24 22 1 800 5 936 28 26 2 000 6 596 32 30 2 200 7 255 36 33 2 400 7 915 40 37 2 600 8 574 44 41 2 800 9 234 48 42 3 000 9 893 12ALS - LOW PRESSURE - 3000 PSI OUTPUT SPEED OUTPUT TORQUE GPM RPM PSI FT-LBS 8 6 1 000 4 148 12 9 1 200 4 978 16 12 1 400 5 808 20 15 1 600 6 637 24 18 1 800 7 467 28 21 2 000 8 296 32 24 2 200 9 126 36 27 2 400 9 956 40 30 2 600 10 785 44 33 2 800 11 615 48 35 3 000 12 445 10/31/2023Kenneth F. Wheeler, P.E.PE #60417 Cool and Cobb Engineering Co. 203 W. Main St. Avon Park, FL 33825 DATE DRAWN BY DWG NO.REV L5, L7 - Leads HDM-5781012AK7/12/2017 - 3.00" Pitch 2.875" O.D. .217" Wall Thickness 7/8" Hole Extension 9.00" Coupling 3-1/2" O.D. w/ .254" Wall Thickness 8" TYP Pilot 5/16" Weld Single Helix Lead Section Double Helix Lead Section Triple Helix Lead Section Typical Pier Assembly -NOTES- 1. Hot-dipped galvanized in accordance with ASTM A123. 2. New Construction Bracket, Repair Bracket, Shaft Coupler, Lead Shafts, and Extensions have a nominal wall thickness. 3. Helical pile lead Shafts and Extensions Are carbon steel piles that conform to API 5 CT L80. Minimum yield strength=80 KSI 4. Shaft couplers are carbon steel pipes that conform to API 5 CT L80. Minimum yield strength= 80 KSI 5. Helix plates are carbon steel plates conforming to ASTM A572, Grade 50. Minimum yield strength=68 KSI. 6. Nominal spacing between helical plates is three times the diameter of the preceding helix plate. 7. Coupling bolts: diameter X 4 long Hex Bolt conforming to SAE J429 Grade 8 with matching hex nuts conforming to SAE J995 Grade 8. 8. 2000 Helical Design & Manufacturing has industry recognized written quality control for all incoming materials, and manufacturing processes. 9. All welding to be done by welders certified under Section 4 of the AWS D1.1/D1, 1M Structural Welding Code-Steel. Leads Leads Part NO."A""B""C""D" L5 NG 8 60" 8" L7 NG 10 84" 10" L5 NG 10 12 60"8"10" L7 NG 10 12 84" 10"12" L7 NG 8 10 12 84" 8"10"12" "B" "C" "D" "A" 45 Lead Do Not Scale 3/8” Thick Cool and Cobb Engineering Co. 203 W. Main St. Avon Park, FL 33825 10/31/2023 Kenneth F. Wheeler, P.E. PE #60417 2000 HELICAL DESIGN AND MANUFACTURING DATE DRAWN BY DWG NO.REV 2000 HELICAL DESIGN AND MANUFACTURING E3, E5, E7 - Extensions HDM-E357AK7/20/2017 - Extension 9" Coupling 3-1/2" DIA w/ .25" Wall Thickness 45 Lead 5/16" Weld Typical Pier Assembly "A" .75 .643".643" 1.11" .75" 1.85" 4" 4.493" 1.11" 3/4-10 UNC Thread 2.875" .217 Wall Thickness Coupling Bolt And Nut 7/8" Extension Extension 3/4x4 Bolt Extension 3/4 Nut Extension Part NO."A" E3 36" E5 60" E7 84" ExtensionsTorque Strength Rating - 9,281 Ft-Lbs Ultimate Capacity (Tension/Compression) - 83.53 Kip * Based On A Torque Factor (Kt)=9 -NOTES- 1. New Construction Bracket, Repair Bracket, Shaft Coupler, Lead Shafts, and Extensions have a nominal wall thickness. 2. Helical pile lead Shafts and Extensions Are carbon steel piles that conform to API 5 CT L80. Minimum yield strength=80 KSI 3. Shaft couplers are carbon steel pipes that conform to API 5 CT L80. Minimum yield strength= 80 KSI 4. Helix plates are carbon steel plates conforming to ASTM A572, Grade 50. Minimum yield strength=68 KSI. 5. Nominal spacing between helical plates is three times the diameter of the preceding helix plate. 6. Coupling bolts: diameter X 4 long Hex Bolt conforming to SAE J429 Grade 8 with matching hex nuts conforming to SAE J995 Grade 8. 7. 2000 Helical Design & Manufacturing has industry recognized written quality control for all incoming materials, and manufacturing processes. 8. All welding to be done by welders certified under Section 4 of the AWS D1.1/D1, 1M Structural Welding Code-Steel. 10/31/2023 Kenneth F. Wheeler, P.E. PE #60417 Cool and Cobb Engineering Co. 203 W. Main St. Avon Park, FL 33825 STANDARD DUTY BRACKET (35 KIPS) HELICAL LEAD – 7’ with 10”/12” Flights, 2 7/8” OD, .217 Wall (MAXIMUM TORQUE NOT TO EXCEED 10,000 FT LBS. ULTIMATE CAPACITY IS 72 KIPS) HELICAL EXTENSION – 7’, 2 7/8” OD, .217 Wall 1418 E. Busch Blvd., Suite 311 Tampa FL 33612 813-930-2846 STANDARD DUTY BRACKET HELICAL EXTENSION HELICAL LEAD 10/31/2023Kenneth F. Wheeler, P.E.PE #60417 Cool and Cobb Engineering Co. 203 W. Main St. Avon Park, FL 33825