337 4th St RES23-0235 COAB Permit Form with ConditionsFinal Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION RES23-0235 337 4th St OWNER BUILDER REPLACE BALCONY OWNER:ADDRESS:CITY:STATE:ZIP: Charles Walker 337 4TH ST ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169835 0000 ATLANTIC BEACH JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 337 4TH ST RESIDENTIAL ALTERATION RESIDENTIAL Replace damaged existing balcony with new.$12000.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $115.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $57.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.59 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00 TOTAL: $277.09 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 11/15/2023 PERMIT NUMBER RES23-0235 ISSUED: 11/15/2023 EXPIRES: 5/13/2024 RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 RES23-0235 JOB COPY JOB COPY JOB COPY By vangers at 11:43 am, Nov 02, 2023 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $277.09 RES23-0235 Address: 337 4TH ST APN: 169835 0000 $277.09 BUILDING $115.00 BUILDING PERMIT 455-0000-322-1000 0 $115.00 BUILDING PLAN REVIEW $57.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $57.50 STATE SURCHARGES $4.59 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.59 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 ZONING PLAN REVIEW $100.00 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00 TOTAL FEES PAID BY RECEIPT: R25522 $277.09 Printed: Wednesday, November 15, 2023 9:10 AM Date Paid: Wednesday, November 15, 2023 Paid By: Charles Walker Pay Method: CREDIT CARD 10116654862 1 of 1 Cashier: TG Cash Register Receipt City of Atlantic Beach Receipt Number R25522 STRUCTURAL NOTES GENERAL NOTES: STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS. CONSULT THESE DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS. THESE PLANS LIMIT THE RESPONSIBILITY TO THE STRUCTURAL REQUIREMENTS OF THE PROJECT ONLY. ARCHITECTURAL, CIVIL, MECHANICAL (PLUMBING AND HVAC), WATERPROOFING, INSULATION, FLASHING, AND BASE FLOOD ELEVATION REQUIREMENTS ARE NOT ADDRESSED. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH THE AFFECTED PART OF THE WORK. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCE TO ENSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS OR TIEDOWNS. BUILDER TO SUBMIT SHOP DRAWINGS OF PROPOSED HANDRAIL CONSTRUCTION FOR APPROVAL BY EOR PRIOR TO CONSTRUCTION & INSPECTION. EXISTING STRUCTURE: INFORMATION SHOWN FOR THE EXISTING STRUCTURE WAS TAKEN BY FIELD INSPECTION AND OBSERVATION BY CONTRACTOR. WORK SHOWN ON THESE PLANS ASSUMES THAT THE ORIGINAL CONSTRUCTION WAS PERFORMED IN ACCORDANCE WITH THE STANDARD BUILDING CODE AND ACCEPTED INDUSTRY PRACTICES AT TIME OF CONSTRUCTION. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE CONDITIONS RELATING TO THE EXISTING STRUCTURE AND TO NOTIFY THE ENGINEER IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICTS. THE ** NON-HABITABLE BALCONY ADDITION*** INCREASES THE LATERAL-FORCE STORY SHEAR BY 1%. THE EXISTING BUILDING CAN RESIST THE ADDITIONAL LATERAL-FORCE STORY SHEAR. THE **NON-HABITABLE LANAI ADDITION** INCREASES THE VERTICAL LOADING ON THE EXISTING STRUCTURE. THE ELEMENTS IN THE EXISTING STRUCTURE THAT ARE SUPPORTING THE ** NON-HABITABLE LANAI ADDITION*** CAN RESIST THE ADDITIONAL VERTICAL LOADING. DESIGN LOADS: THE STRUCTURAL SYSTEM FOR THIS BUILDING HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, 7th EDITION (FBC2020). THE FOLLOWING SUPERIMPOSED LOADINGS HAVE BEEN UTILIZED: ELEVATED FLOORS: LIVE LOAD _40 psf. DEAD LOAD _15 psf. WIND:ASCE 7-16 ULTIMATE WIND SPEED _130 mph ALLOWABLE WIND SPEED _101 mph EXPOSURE C ENCLOSED STRUCTURE RISK FACTOR II DEFLECTION CRITERIA: ROOF MEMBERS HAVE BEEN DESIGNED WITH A DEFLECTION LIMITATION OF L/240 (LIVE LOAD) AND L/180 (TOTAL LOAD). FLOOR MEMBERS HAVE BEEN DESIGNED WITH A DEFLECTION LIMITATION OF L/360 (LIVE LOAD) AND L/240 (TOTAL LOAD) IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND OR ARCHITECT TO NOTIFY THE E.O.R. IF DEFLECTION CRITERIA SHALL BE REVISED TO MORE STRICT REQUIREMENTS. SHOP DRAWING REVIEW: SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGN INTENT OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC. ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTOR PRIOR TO SUBMITTAL TO THE ARCHITECT/ENGINEER. DRAWINGS SUBMITTED WITHOUT REVIEW NOTATION WILL BE RETURNED UNCHECKED. ONE SET OF PRINTS WILL BE RETAINED BY THE ENGINEER AND ONE BY THE ARCHITECT, THE CONTRACTOR SHALL RECEIVE THE REMAINING PRINTS FOR SUBMITTAL TO THE BUILDING DEPARTMENT AND AS REQUIRED FOR DISTRIBUTION. IN ALL INSTANCES THE CONTRACT DOCUMENTS WILL GOVERN OVER THE SHOP DRAWINGS UNLESS OTHERWISE SPECIFIED IN A REQUEST FOR INFORMATION (RFI) OR SIMILAR DOCUMENTATION BY THE ENGINEER. SHOP DRAWINGS SHOULD BE SUBMITTED FOR ALL COMPONENTS OF THE STRUCTURAL FRAMING SYSTEM, AS REQUIRED BY THE ARCHITECT, AND AS NOTED ELSEWHERE IN THESE NOTES, INCLUDING, BUT NOT LIMITED TO: CONCRETE MIX DESIGNS CONCRETE REINFORCEMENT STRUCTURAL STEEL (INCLUDING ANCHOR BOLTS) ANY ALTERNATE MATERIAL/PRODUCT SUBSTITUTIONS FOUNDATIONS: ARE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 psf ON COMPACTED FILL OR NATIVE SOIL. BEFORE CONSTRUCTION COMMENCES, SOIL BEARING CAPACITY SHALL BE VERIFIED BY A SUBSURFACE INVESTIGATION, AS WELL AS FIELD AND LABORATORY TESTS PERFORMED BY A CERTIFIED TESTING LABORATORY, WHOSE REPORT SHALL INCLUDE ANALYSIS AND RECOMMENDATIONS FOR SITE PREPARATION IN ORDER TO BEAR THE FOUNDATION LOADS. ABOVE REPORT SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW BEFORE FOUNDATION CONSTRUCTION BEGINS. FORMWORK AND SHORING: NO STRUCTURAL CONCRETE SHALL BE STRIPPED UNTIL IT HAS REACHED AT LEAST TWO_THIRDS OF THE 28 DAY DESIGN STRENGTH. DESIGN, ERECTION AND REMOVAL OF ALL FORMWORK, SHORES AND RESHORES SHALL MEET THE REQUIREMENTS SET FORTH IN ACI STANDARDS 347 AND 301. REINFORCING STEEL: SHALL BE ASTM A615 GRADE 60 DEFORMED BARS, FREE FROM OIL, SCALE AND RUST AND PLACED IN ACCORDANCE WITH THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF ACI STANDARDS AND SPECIFICATIONS. SECURE APPROVAL OF SHOP DRAWINGS PRIOR TO COMMENCING FABRICATION. WELDED WIRE FABRIC: TO CONFORM TO ASTM A_185, FREE FROM OIL, SCALE AND RUST AND PLACED IN ACCORDANCE WITH THE TYPICAL PLACING DETAILS OF ACI STANDARDS AND SPECIFICATIONS. MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. CONCRETE: SHALL BE PER AN APPROVED MIX DESIGN PROPORTIONED TO ACHIEVE A STRENGTH AT 28 DAYS AS LISTED BELOW WITH A PLASTIC AND WORKABLE MIX: 3000 psi FOR FOUNDATIONS AND SLABS ON GRADE. 4000 psi FOR ALL OTHER STRUCTURAL CONCRETE. CONCRETE SHALL BE PLACED AND CURED ACCORDING TO ALL STANDARDS AND SPECIFICATIONS. SUBMIT PROPOSED MIX DESIGN WITH RECENT FIELD CYLINDER OR LAB TESTS FOR REVIEW PRIOR TO USE. MIX SHALL BE UNIQUELY IDENTIFIED BY MIX NUMBER OR OTHER POSITIVE IDENTIFICATION. MIX SHALL MEET THE REQUIREMENTS OF ASTM C33 FOR COARSE AGGREGATE. FOR ALL FLATWORK, AT LEAST 75% OF LARGE AGGREGATE SHALL CONSIST OF #57 STONE. CONCRETE SHALL COMPLY WITH ALL THE REQUIREMENTS OF ASTM STANDARD C94 FOR MEASURING, MIXING, TRANSPORTING, ETC. CONCRETE TICKETS SHALL BE TIME STAMPED WHEN CONCRETE IS BATCHED. THE MAXIMUM TIME ALLOWED FROM THE TIME THE MIXING WATER IS ADDED UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED ONE AND ONE HALF (1_1/2) HOURS. IF FOR ANY REASON THERE IS A LONGER DELAY THAN THAT STATED ABOVE, THE CONCRETE SHALL BE DISCARDED. IT SHALL BE THE RESPONSIBILITY OF THE TESTING LAB TO NOTIFY THE OWNER'S REPRESENTATIVE AND THE CONTRACTOR OF ANY NONCOMPLIANCE WITH THE ABOVE. ALL SLABS SHALL BE CURED USING A DISSIPATING CURING COMPOUND MEETING ASTM STANDARD C309 TYPE 1-D AND SHALL HAVE A FUGITIVE DYE. THE COMPOUND SHALL BE PLACED AS SOON AS THE FINISHING IS COMPLETED OR AS SOON AS THE WATER HAS LEFT THE UNFINISHED CONCRETE. ALL SCUFFED OR BROKEN AREAS IN THE CURING MEMBRANE SHALL BE RECOATED DAILY. CALCIUM CHLORIDES SHALL NOT BE UTILIZED; OTHER ADMIXTURES MAY BE USED ONLY WITH THE APPROVAL OF THE ENGINEER. ALL CONCRETE MIX DESIGNS SHALL INCLUDE A WRITTEN DESCRIPTION INDICATNG WHERE EACH PARTICULAR MIX IS TO BE PLACED WITHIN THE STRUCTURE. ALL CONCRETE DESIGN MIX SUBMITTALS SHALL INCLUDE TESTED, STATISTICAL BACK_UP DATA AS PER CHAPTER 26 OF ACI 318_14 AND ACI 214R. WATER/CEMENT RATIO FOR CONCRETE AT EXTERIOR BALCONIES SHALL NOT EXCEED 0.40 BY WEIGHT AND HAVE 5,000psi MINIMUM COMPRESSIVE CAPACITY. CONCRETE MIX FOR POOL WALLS AND SLABS SHALL LIMIT SHRINKAGE TO 0.04%-0.03%. SUPPLIER SHALL SUBMIT SHRINKAGE TEST RESULTS FOR APPROVAL PRIOR TO OREDERING. UNLESS NOTED OTHERWISE ON PLANS, THE FOLLOWING CONCRETE CLEAR COVER SHALL BE PROVIDED FOR ALL NON-PRESTRESSED CONCRETE REINFORCEMENT PER ACI 318: CONCRETE CAST AGAINST EARTH:ALL BARS -3" CONCRETE EXPOSED TO EARTH (FORMED FACE):ALL BARS -2" CONCRETE EXPOSED TO WEATHER:#6 BARS AND GREATER -2" #5 BARS AND SMALLER -1 1/2" WHERE NOT EXPOSED TO EARTH OR WEATHER: SLABS, WALLS, AND JOISTS:#14 & #18 BARS -1 1/2" #11 BARS AND SMALLER -3/4" BEAMS AND COLUMNS: ALL BARS -1 1/2" SURFACE EXPOSED TO WATER (POOLS, TANKS, ETC.): ALL BARS - 2” SEE ACI 318 FOR ADDITIONAL REQUIREMENTS AND MORE INFORMATION CONCRETE TESTING: AN INDEPENDENT TESTING LABORATORY SHALL PERFORM THE FOLLOWING TESTS ON CAST IN PLACE CONCRETE: A)ASTM C143 _ "STANDARD TEST METHOD FOR SLUMP OF PORTLAND CEMENT CONCRETE." MAXIMUM SLUMP SHALL BE 4-6 INCHES, PRIOR TO ADDING A SUPER PLASTISIZER. B)ASTM C39 _ "STANDARD TEST METHOD FOR COMPRESSIVE STRENGTH OF CYLINDRICAL CONCRETE SPECIMENS." A SEPARATE TEST SHALL BE CONDUCTED FOR EACH CLASS, FOR EVERY 50 CUBIC YARDS (OR FRACTION THEREOF), PLACED PER DAY. REQUIRED CYLINDER(S) QUANTITIES AND TEST AGE AS FOLLOWS: 1 AT 3 DAYS 1 AT 7 DAYS 2 AT 28 DAYS ONE ADDITIONAL RESERVE CYLINDER TO BE TESTED UNDER THE DIRECTION OF THE ENGINEER, IF REQUIRED. IF 28 DAY STRENGTH IS ACHIEVED, THE ADDITIONAL CYLINDER(s) MAY BE DISCARDED. WOOD: STRUCTURAL WOOD COMPONENTS (BEAMS, JOISTS, RAFTERS, ETC.) SHALL HAVE THE FOLLOWING MINIMUM ALLOWABLE FIBER STRESSES FOR No. 2 SOUTHERN PINE CONFORMING TO NDS, WITH 2015 SUPPLEMENT, AS FOLLOWS: SHEAR ALL Fv = 175 psi. BENDING 2X6 Fb = 1,000 psi. BENDING 2X8 Fb = 925 psi. BENDING 2X10 Fb = 800 psi. BENDING 2X12 Fb = 750 psi. WOOD IN CONTACT WITH CONCRETE OR MASONRY, AND AT OTHER LOCATIONS AS SHOWN ON STRUCTURAL DRAWINGS, SHALL BE PROTECTED OR PRESSURE TREATED IN ACCORDANCE WITH AITC_109. MEMBER SIZES SHOWN ARE NOMINAL UNLESS NOTED OTHERWISE. *ALL NAILS SHOWN ON PLANS ASSUME COMMON WIRE NAILS UNLESS SPECIFICALLY NOTED ON DRAWINGS.* HEADER FRAMING ·ALL JACK AND KING STUDS SHALL BE FASTENED TO EACH OTHER WITH (2) ROWS 0.148" @ 8" O.C. STAGGERED. ·SHEATHING FASTENED TO HEADERS SHALL MATCH EXTERIOR WALLS. ·ATTACH HEADERS TO ALL FRAMING MEMBERS (KING STUD, TOP PLATE, HEADER SILL) W/ 0.131" NAILS @ 3" O.C. ·EITHER TOP OR BOTTOM PLY OF DBL TOP PLATE MUST SPAN CONTINUOUS OVER OPENING; SHEATHING MUST BE EDGE NAILED TO CONTINUOUS PLY OF PLATE. ·HEADERS CAN BE INSTALLED FLUSH OR DROPPED. IF DROPPED PROVIDE CRIPPLE STUD AT EACH END AND AT WALL STUD SPACING. ·WALL SHEATHING ABOVE OPENING MUST BE CONTINUOUS FROM TOP OF PLATE TO HEADER BELOW OR SILL PLATE ABOVE OPENING ·FASTEN ALL MULTI-PLY HEADERS TOGETHER WITH 0.148" NAILS @ 3" O.C. ROWS AND 0.148" NAILS @ 8" O.C., ALONG LENGTH OF HEADER. ·IF HEADER NOT SPECIFIED, USE HEADER SCHEDULE. ·U.N.O. ON PLAN, MIN (1) SDWC15600 TOP PL TO EACH KING STUD AND (1) SDWC15450 KING STUD TO EACH BOTTOM PLATE CONNECTION REQUIRED EACH SIDE OF OPENING. ·TOP PL TO HEADER CONNECTION PER ONE OF THE FOLLOWING : ··SDWC15600 @ MAX 32" O.C. ··SIMPSON SPH @ 16" O.C. OR DSP @ 16" O.C. OR FASTEN TRUSS DIRECTLY TO HEADER w/ MTS OR HTS w/ (14) 0.148" x 1-1/2" (OR EQUAL APPROVED BY EOR). WHEN STRAPPING BETWEEN FLOORS, NAILS ARE ONLY REQUIRED IN STUDS ABOVE, & BELOW. WHEN STRAP OCCURS ABOVE AN OPENING BELOW, THE STRAP SHALL BE FASTENED DIRECTLY TO HEADER (BYPASS CRIPPLE). WRAP STRAP AROUND BOTTOM OF HEADER AS REQUIRED TO MEET STRAP END LENGTH AND AMOUNT OF NAILS. TO PREVENT STRAP BUCKLING, WAIT TO INSTALL LOWER PORTION OF STRAP UNTIL FINAL ROOF DEAD LOAD HAS BEEN APPLIED TO THE STRUCTURE OR, FILL NAIL HOLES IN STRAP IN FLOOR CAVITY AREA. ROOF, FLOOR, AND WALL SHEATHING ARE DESIGNED AS DIAPHRAGMS AND SHALL COMPLY WITH APPLICABLE PROVISIONS OF CHAPTER 23 OF THE FLORIDA BUILDING CODE AND SHALL BE FASTENED IN ACCORDANCE WITH THE STRUCTURAL PLANS, NOTES, AND DETAILS. IF NOT SPECIFIED USE MINIMUM REQUIREMENTS OF FBC TABLE 2304.10.1. ATTACHMENT OF SHEATHING TO RESIST WIND PRESSURES SHALL ALSO NOT BE LESS THAN WHAT IS SHOWN IN FBC TABLE 2304.6.1, UNLESS SHOWN OTHERWISE. ALL SHEATHING FOR SHEARWALLS AND DIAPHRAGMS SHALL BE OF STRUCTURAL I GRADE. DIAPHRAGM SHEATHING SHALL BE ORIENTED PERPENDICULAR TO FLOOR AND ROOF FRAMING. LAYOUT OF ADJACENT SHEATHING PANELS SHALL BE STAGGERED AS IN CASES 1 THROUGH 4 IN FBC 2306.2(1). ALL DIAPHRAGMS AND SHEARWALLS SHALL BE BLOCKED AT PANEL EDGES WITH 2X4 BLOCKING ORIENTED FLAT-WISE (LONG FACE PARALLEL TO SHEATHING). SUBFLOOR SHALL BE GLUED TO PREVENT SQUEAKING. MINIMUM FASTENING REQUIREMENTS FOR BUILT UP WOOD FRAMING, BLOCKING, MEMBER CONNECTIONS AND SHEATHING SHALL NOT BE LESS THAN THAT SET FORTH IN FBC TABLE 2304.10.1. MANUFACTURED WOOD STRUCTURAL COMPONENTS: MEMBERS DESIGNATED 'LVL' (E.G., 1_3/4 X 14 LVL) SHALL BE LAMINATED VENEER LUMBER AS MANUFACTURED BY WEYERHAEUSER COMPANY (MICRO=LAM), OR ENGINEER APPROVED SUBSTITUTION. Fb = 2600 psi, E = 2,000,000 psi, Fv = 285 psi. DEPTH SHOWN ARE MIN. REQ'D. LARGER BEAMS CAN BE USED WITH VERIFICATION FROM ARCHITECT. WOOD FRAMING CONNECTORS: ALL CONNECTORS SHALL BE GALVANIZED OR STAINLESS STEEL. CONNECTOR MODEL NUMBERS SHOWN ARE STRONG-TIE CONNECTORS AS MANUFACTURED BY SIMPSON STRONG-TIE CO., 5956 W. LAS POSITAS BLVD., P.O. BOX 10789, PLEASANTON, CA 94588, 800-999-5099, WWW.STRONGTIE.COM. SUBSTITUTIONS ARE ACCEPTABLE WITH THE APPROVAL OF THE STRUCTURAL ENGINEER. UNLESS SHOWN OTHERWISE, INSTALL SIZE AND **MAXIMUM** NUMBER OF FASTENERS SHOWN IN LATEST SIMPSON CATALOG. L L T.O.TOP OF COL.COLUMN SIM.SIMILAR SEC.SECTION DET.DETAIL FDN FOUNDATION SS STAINLESS STEEL RECT.RECTANGULAR OVERALL HEIGHTOAH DL DEAD LOAD CONT.CONTINUOUS BW BUTTWELD L.P.LOW POINT THREADEDTHD KLF KIPS PER LINEAR FOOT PROJ PROJECTION MAX.MAXIMUM HSB HIGH STRENGTH BOLT CONNECTIONCONN. DIAMETER Ø OR DIA. A.B.ANCHOR BOLT B.O.BOTTOM OF B.P.BASE PLATE C CENTERLINE CLR.CLEAR CMU CONCRETE MASONRY UNIT E.S.EACH SIDE EL.ELEVATION EMBED.EMBEDMENT EXIST.EXISTING F.O.F.FACE OF FLANGE TOP OF STEELT/STL. TOP OF CONCRETET/CONC. REFERENCEREF. PLATEP OUTSIDEO.S. OUTSIDE DIAMETERO.D. NEAR SIDEN.S. MINIMUMMIN. MANUFACTURERMFG LONG LEG VERTICALLLV LONG LEG HORIZONTALLLH LOCK WASHERL.W. INSIDE DIAMETERI.D. GALVANIZEDGALV. FLAT WASHERF.W. FAR SIDEF.S. UNLESS NOTED OTHERWISEU.N.O. TYPICALTYP. ABOVE FINISH FLOORA.F.F. BOTTOMBTM. CONCRETECONC. NOM.NOMINAL OVERALL LENGTHOAL ON CENTERO.C. R RISER (FOR STAIRS) OR RADIUS REQ'D.REQUIRED T & B TOP & BOTTOM SQ.SQUARE HT.HEIGHT WWF WELDED WIRE FABRIC K.B.KNEE BRACE DITTOdo DIST DISTANCE INCL.INCLUDED KIPS PER SQUARE INCHKSI LL LIVE LOAD OR DOUBLE ANGLE MAT'L.MATERIAL NOT APPLICABLEN/A POUNDS PER LINEAR FOOTPLF PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH ABBREVIATIONS BELOW FINISH FLOORB.F.F. ALL THREAD RODA.T.R. SCHED.SCHEDULE ARCHITECTURAL PLANARCH. A B C D E F G H I K L M N O P R S T U/W E.E.EACH END SYP SOUTHERN YELLOW PINE WCS WOOD CONNECTOR SCHEDULE ADJACENTADJ QTY QUANTITYQ EQ EQUIVALENT CAPACITY FINISH FLOORF.F. LAP PLIES AND ATTACH W/(5) 0.148"x3" NAILS PER PLY PLAN VIEW AT TOP OF CORNER POST TYPICAL WOOD PORCH COLUMN SCALE: NTS SEE COLUMN SCHEDULE FOR SIZE AND ATTACHMENT. THREADED ROD (DIAMETER PER SIMPSON MANUAL) W/ 8" MIN. EMBEDMENT. WOOD BEAM, SEE PLAN FOR SIZE. WOOD BEAM, SEE PLAN FOR SIZE. POST BASE PER COLUMN SCHEDULE MATCHING NOMINAL SIZE OF COLUMN. OPTIONAL TOP PLATES CORNER BEAM 6" MIN.CS20 U.N.O. ON PLAN. BEAM EACH SIDE 2" MIN. CS20 U.N.O. ON PLAN. 11"x11" CONCRETE PEDESTAL, W/ (4) #5 VERTICAL BARS AND (2) #3 TIES.3"MAX.6"MIN.1'-6"CONCRETE FOOTING, SEE PLAN & FOOTING SCHEDULE FOR SIZE & REINF. WELL COMPACTED SOIL. SEE GEOTECHNICAL REPORT. NO SLAB OPTION FASTENERS ROWS 10" O.C. MAX SPACING (TYP.). TYPICAL ENG-LUMBER BUILT UP MEMBER FASTENING (SIDE LOADED) SCALE: NTS0"-714"(2 FASTENERS)712"-1114"(3 FASTENERS)1112"-14"(4 FASTENERS)1"(MIN.)SDW22338 SDW22500 SDW22634 2-PLY 3-PLY 4-PLY OFFSET OPP. SIDE BY 5" STRUCTURAL NOTES S100WALKERRESIDENCE337 4TH ST.ATLANTIC BEACH,FL 32233TO THE BEST OF MY KNOWLEDGE AND ABILITY, THE COMPLETED STRUCTURE DEPICTEDON THE PLANS COMPLIES WITH THE APPLICABLE MINIMUM BUILDING CODES. 209 Bilbao Dr. St. Augustine, FL 32086 (904) 685-8806 REV/DATE/DESCRIPTION ENGINEER OF RECORD SWANSON STRUCTURAL, INC. 209 BILBAO DR. ST. AUGUSTINE, FL 32086 DATE ISSUED: 10.24.2023 PROJECT NUMBER 23-071 SHEET TITLE SHEET NUMBER Swanson Structural, Inc. COA #34434 THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY KYLE E. RUNK, PE, ON October 24, 2023 PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES Kyle E. Runk Digitally signed by Kyle E. Runk DN: C=US, E=KRunk@swansonstruct.com, O="Swanson Structural, Inc", OU="FL P.E. #94215", CN=Kyle E. Runk Date: 2023.10.24 10:49:47-04'00' Reviewed for code compliance CEP BU1699 11/02/2023 7:11:41 AM NOTES: 1.ALL BARS ARE BOTTOM BARS U.N.O. 2.E.W.= EACH WAY, T&B= TOP AND BOTTOM, S.W. = SHORT WAY, L.W.= LONG WAY. SYMBOL SIZE W x L NOTES FOOTING SCHEDULE DEPTH REINFORCING 12"2 #5 E.W. BOT.2'-0"x2'-0"2x2 3'-914"8'2x2 W1 OUTSIDE OF STRUCTURAL SCOPE EXISTING ASSUMED FOUNDATIONS. MINIMUM DIMENSIONS SHOWN (16"x8"d). CONTRACTOR TO VERIFY EXISTING CONDITIONS AND NOTIFY E.O.R. IF MINIMUM SIZES ARE NOT MET OR CONFIGURATION IS INACCURATE. SEE TYP. DETAILS FOR COLUMN BASE (TYP.). 2x2 W1 ATTACH COLUMN TO EXISTING FRAMING w/ SDWS22800DB @ 8" O.C. (STAGGERED) (3) #5 DOWELLS SEE TYP. DETAILS CONCRETE SEE DETAIL "F1/S200" FOUNDATION & GROUND LEVEL PLAN NOTES ·VERIFY ALL DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. SEE ARCHITECTURAL AND MEP FOR ADDITIONAL INFORMATION. ·ELEVATIONS SHOWN ARE RELATIVE TO THE GROUND FLOOR SLAB SURFACE SET AT 0'-0" (REF.). ·ALL WOOD USED IN EXTERIOR APPLICATIONS OR IN CONTACT W/ CONCRETE OR MASONRY SHALL BE PRESSURE TREATED WITH PRESERVATIVE. (P.T.) EXTERIOR CONNECTORS SHALL BE HOT DIPPED GALVANIZED. ·CENTERLINES OF WALLS AND COLUMNS SHALL COINCIDE WITH CENTERLINES OF FOOTINGS AT ALL LOCATIONS, U.N.O. ·TOP OF FOOTING ELEVATION SET AT TOP OF GRADE UNLESS NOTED OTHERWISE. ALL THICKENED EDGE (TE) AND THICKENED SLABS (TS) TO BE AT TOP OF SLAB ELEVATION. DONT MOVE FOUNDATION LEGEND 1. OR INDICATES FOUNDATION CALL OUT. SEE FOUNDATION SCHEDULE FOR SIZE AND REINFORCING REQUIREMENTS. 2. WOOD CONNECTOR OR FASTENERS. TRIM OR SHIM AS REQUIRED (34" EACH SIDE MAX.) FOR SNUG FITTING CONNECTION. IF CONNECTOR SIZE IS NOT SHOWN, SIZE SHALL BE BASED ON MEMBER SIZES SHOWN ON PLAN. 3. STRUCTURAL THRU COLUMN. SEE COLUMN SCHEDULE FOR SIZE, MATERIAL, AND REQUIREMENTS. 3.1. COLUMN BELOW. 3.2. COLUMN ABOVE. 4. SECTION MARK AT THIS LOCATION IS A SIMILAR CONDITION WITH MINOR DIFFERENCES TO SECTION DRAWN. # (#)-X#X# ?? ?? ?? (SIM.) DONT MOVE "TE-#" "TS-#" DONT MOVE WOOD COLUMN SCHEDULE SIZE (INCH)POST BASE (U.N.O. ON PLAN) POST CAP (U.N.O. ON PLAN)MATERIAL TYPE COLUMN SCHEDULE NOTES: 1.ALL CONNECTORS SPECIFIED SHALL BE INSTALLED WITH SIZE AND **MAXIMUM** NUMBER OF FASTENERS SHOWN IN LATEST SIMPSON CATALOG. 2.WOOD COLUMNS SHALL BE 6" MIN. ABOVE ADJACENT FINAL GRADE. PROVIDE BLOCK OR CONCRETE PEDESTAL IF NEEDED TO RAISE COLUMN BASE. SEE TYPICAL DETAIL. SYMBOL 6"x6" (NOM.) SEE PLAN/TYP. DETAILS SOUTHERN PINE No.2W1 ABU66 w/ 58"Ø ANCHOR AND 8" EMBED W1 A B1 S200 OUTSIDE OF STRUCTURAL SCOPE 3-PLY PWT 1 34" x 9 12" LVL2x12's @ 12" O.C.(DO NOT TAPER CUT)W1 3'-612"MAXCANTILEVER8'-512"6'-0" MAX CANTILEVER 4'-0" 2ND FLOOR FRAMING PLAN NOTES 1.VERIFY ALL DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. SEE ARCHITECTURAL AND MEP FOR ADDITIONAL INFORMATION. SEE ARCHITECTURAL DRAWING FOR WINDOW LOCATIONS. 2.ALL WOOD USED IN EXTERIOR APPLICATIONS OR IN CONTACT W/ CONCRETE OR MASONRY SHALL BE PRESSURE TREATED WITH PRESERVATIVE. (P.T.) EXTERIOR CONNECTORS SHALL BE STAINLESS STEEL. 3.FLOOR FRAMING SHALL CONSIST OF 2x12 FLOOR JOISTS AT 12" O.C. AS SHOWN ON PLAN. 2ND FLOOR LEGEND 1. WOOD LEDGER FOR TRUSS/JOISTS OR SHEATHING BEARING. SEE LEDGER SCHEDULE FOR SIZE AND CONNECTION REQUIREMENTS. 2. WOOD CONNECTOR OR FASTENERS. TRIM OR SHIM AS REQUIRED (34" EACH SIDE MAX.) FOR SNUG FITTING CONNECTION. IF CONNECTOR SIZE IS NOT SHOWN, SIZE SHALL BE BASED ON MEMBER SIZES SHOWN ON PLAN. EE = EACH END, ES = EACH SIDE. 3. STRUCTURAL THRU COLUMN. SEE COLUMN SCHEDULE FOR SIZE, MATERIAL, AND REQUIREMENTS. 3.1. COLUMN BELOW. 3.2. COLUMN ABOVE. 4. SECTION MARK AT THIS LOCATION IS A SIMILAR CONDITION WITH MINOR DIFFERENCES TO SECTION DRAWN. (#)-X#X# ?? ?? ?? (SIM.) A 2"SPACING IN TABLE 3" TO 6"2"3"LEDGER/NAILER SCHEDULE MARK PLYS & NOM. SIZE (INCH) CONNECTING MATERIAL 1.ALL LEDGERS AND NAILERS ARE ARE SOUTHERN PINE No.2 GRADE U.N.O. 2.LEDGERS AND NAILERS SHALL BE PRESSURE TREATED WHEN IN CONTACT WITH CONCRETE/C.M.U. 3.ROWS OF FASTENERS SHALL BE STAGGERED BY SPACING LISTED IN TABLE UNLESS ATTACHING TO STUDS OR TRUSSES OR OTHERWISE NOTED. 4.SEE DIAGRAM BELOW FOR ADDITIONAL REQUIREMENTS. 5.ROOF LEDGERS SHALL MATCH TOP OF TRUSS/RAFTER ELEVATION AND FOLLOW ROOF SLOPE. QNTY/SIZE/TYPE/SPACING OF FASTENERS OR ANCHORS SPECIFIC NOTES MIN.2x12 EACH FLOOR TRUSS/ WALL STUD. A (4) SDWS22400DB AT 24" O.C. MAX. SCALE: B1 S200 SECTION WOOD BEAM, SEE PLANS FOR SIZE. 2x JOISTS. SEE W.C.S. FOR UPLIFT CONNECTOR. 2x12 CONT. RIM BOARD. SEE W.C.S. FOR ATTACHMENT REQUIREMENTS. PROVIDE FULL DEPTH BLOCKING. ATTACH TO BEAM BELOW w/ 0.131"x3" TOENAILS @ 3" O.C. AND (3) 0.131"x3" TOENAILS E.S. TO ADJACENT JOIST. WOOD CONNECTOR SCHEDULE: 1.FLOOR JOISTS: 1.1.TO BEAM BELOW - (1) H2.5A OR (1) SDWC15600 SCREW 1.2.TO FACE OF BEAM/LEDGER - LUS212 2.RIM BOARD: 2.1.TO EACH JOIST - (5) 16d ENDNAILS (E.S.) W.C.S. SCALE: F1 S200 SECTION WALKERRESIDENCE337 4TH ST.ATLANTIC BEACH,FL 32233TO THE BEST OF MY KNOWLEDGE AND ABILITY, THE COMPLETED STRUCTURE DEPICTEDON THE PLANS COMPLIES WITH THE APPLICABLE MINIMUM BUILDING CODES. 209 Bilbao Dr. St. Augustine, FL 32086 (904) 685-8806 REV/DATE/DESCRIPTION ENGINEER OF RECORD SWANSON STRUCTURAL, INC. 209 BILBAO DR. ST. AUGUSTINE, FL 32086 DATE ISSUED: 10.24.2023 PROJECT NUMBER 23-071 SHEET TITLE SHEET NUMBER Swanson Structural, Inc. COA #34434 THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY KYLE E. RUNK, PE, ON October 24, 2023 PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES FOUNDATION AND SECOND LEVEL BALCONY PLAN S200 FOUNDATION PLAN SECOND LEVEL BALCONY PLAN Scale:1/4" = 1'-0" Scale:1/4" = 1'-0"Kyle E. Runk Digitally signed by Kyle E. Runk DN: C=US, E=KRunk@swansonstruct.com, O="Swanson Structural, Inc", OU="FL P.E. #94215", CN=Kyle E. Runk Date: 2023.10.24 10:50:00-04'00' Reviewed for code compliance CEP BU1699 11/02/2023 7:11:32 AM Revision Request/Correction to Comments **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED.City of Atlantic Beach Building Department 800 Seminole Rd,Atlantic Beach,FL 32233 Phone:(904)247-5826 Email:Building-Dept@coab.us PERMIT #:_____________________ Revision to Issued Permit OR Corrections to Comments Date:________________ Project Address:____________________________________________________________________________________ Contractor/Contact Name:____________________________________________________________________________ Contact Phone:______________________________Email:_________________________________________________ Description of Proposed Revision /Corrections: __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ I_______________________________affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) !Will proposed revision/corrections add additional square footage to original submittal? No Yes (additional s.f.to be added:_____________________________) !Will proposed revision/corrections add additional increase in building value to original submittal? No *Yes (additional increase in building value:$____________________)(Contractor must sign if increase in valuation) *Signature of Contractor/Agent:_______________________________________________________ __________________________________________________________________________________________________ (Office Use Only) Approved Denied Not Applicable to Department Permit Fee Due $_______________ Revision/Plan Review Comments_______________________________________________________________________ __________________________________________________________________________________________________ Department Review Required: Building _____________________________________________ Planning &Zoning Reviewed By Tree Administrator Public Works Public Utilities _____________________________________________ Public Safety Date Fire Services Updated 10/17/18 RES23-0235 11/07/2023 337 4TH ST CHARLES WALKER 982-9851 CJWALKER8@YAHOO.COM The balcony has been adjusted to 6 ft from 10 ft. This will mean the balcony only projects 2 ft off of the side yard as requested. CHARLES WALKER By Toni Gindlesperger at 11:40 am, Nov 09, 2023 NOTES: 1. ALL BARS ARE BOTTOM BARS U.N.O. 2. E.W.= EACH WAY, T&B= TOP AND BOTTOM, S.W. = SHORT WAY, L.W.= LONG WAY. SYMBOL SIZE W x L NOTES FOOTING SCHEDULE DEPTH REINFORCING 12"2 #5 E.W. BOT.2'-0"x2'-0"2x2 3'-914"8'2x2 W1 OUTSIDE OF STRUCTURAL SCOPE EXISTING ASSUMED FOUNDATIONS. MINIMUM DIMENSIONS SHOWN (16"x8"d). CONTRACTOR TO VERIFY EXISTING CONDITIONS AND NOTIFY E.O.R. IF MINIMUM SIZES ARE NOT MET OR CONFIGURATION IS INACCURATE. SEE TYP. DETAILS FOR COLUMN BASE (TYP.). 2x2 W1 ATTACH COLUMN TO EXISTING FRAMING w/ SDWS22800DB @ 8" O.C. (STAGGERED) (3) #5 DOWELLS SEE TYP. DETAILS CONCRETE SEE DETAIL "F1/S200" FOUNDATION & GROUND LEVEL PLAN NOTES ·VERIFY ALL DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. SEE ARCHITECTURAL AND MEP FOR ADDITIONAL INFORMATION. ·ELEVATIONS SHOWN ARE RELATIVE TO THE GROUND FLOOR SLAB SURFACE SET AT 0'-0" (REF.). ·ALL WOOD USED IN EXTERIOR APPLICATIONS OR IN CONTACT W/ CONCRETE OR MASONRY SHALL BE PRESSURE TREATED WITH PRESERVATIVE. (P.T.) EXTERIOR CONNECTORS SHALL BE HOT DIPPED GALVANIZED. ·CENTERLINES OF WALLS AND COLUMNS SHALL COINCIDE WITH CENTERLINES OF FOOTINGS AT ALL LOCATIONS, U.N.O. ·TOP OF FOOTING ELEVATION SET AT TOP OF GRADE UNLESS NOTED OTHERWISE. ALL THICKENED EDGE (TE) AND THICKENED SLABS (TS) TO BE AT TOP OF SLAB ELEVATION. DONT MOVE FOUNDATION LEGEND 1. OR INDICATES FOUNDATION CALL OUT. SEE FOUNDATION SCHEDULE FOR SIZE AND REINFORCING REQUIREMENTS. 2. WOOD CONNECTOR OR FASTENERS. TRIM OR SHIM AS REQUIRED (34" EACH SIDE MAX.) FOR SNUG FITTING CONNECTION. IF CONNECTOR SIZE IS NOT SHOWN, SIZE SHALL BE BASED ON MEMBER SIZES SHOWN ON PLAN. 3.STRUCTURAL THRU COLUMN. SEE COLUMN SCHEDULE FOR SIZE, MATERIAL, AND REQUIREMENTS. 3.1. COLUMN BELOW. 3.2. COLUMN ABOVE. 4.SECTION MARK AT THIS LOCATION IS A SIMILAR CONDITION WITH MINOR DIFFERENCES TO SECTION DRAWN. # (#)-X#X# ?? ?? ?? (SIM.) DONT MOVE "TE-#" "TS-#" DONT MOVE WOOD COLUMN SCHEDULE SIZE (INCH)POST BASE (U.N.O. ON PLAN) POST CAP (U.N.O. ON PLAN)MATERIAL TYPE COLUMN SCHEDULE NOTES: 1. ALL CONNECTORS SPECIFIED SHALL BE INSTALLED WITH SIZE AND **MAXIMUM** NUMBER OF FASTENERS SHOWN IN LATEST SIMPSON CATALOG. 2. WOOD COLUMNS SHALL BE 6" MIN. ABOVE ADJACENT FINAL GRADE. PROVIDE BLOCK OR CONCRETE PEDESTAL IF NEEDED TO RAISE COLUMN BASE. SEE TYPICAL DETAIL. SYMBOL 6"x6" (NOM.) SEE PLAN/TYP. DETAILS SOUTHERN PINE No.2W1 ABU66 w/ 58"Ø ANCHOR AND 8" EMBED W1 A B1 S200 OUTSIDE OF STRUCTURAL SCOPE 3-PLY PWT 1 34" x 9 12" LVL2x12's @ 12" O.C.(DO NOT TAPER CUT)W1 3'-612"MAXCANTILEVER8'-512"2'-0" MAX CANTILEVER 4'-0" 2ND FLOOR FRAMING PLAN NOTES 1. VERIFY ALL DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. SEE ARCHITECTURAL AND MEP FOR ADDITIONAL INFORMATION. SEE ARCHITECTURAL DRAWING FOR WINDOW LOCATIONS. 2. ALL WOOD USED IN EXTERIOR APPLICATIONS OR IN CONTACT W/ CONCRETE OR MASONRY SHALL BE PRESSURE TREATED WITH PRESERVATIVE. (P.T.) EXTERIOR CONNECTORS SHALL BE STAINLESS STEEL. 3. FLOOR FRAMING SHALL CONSIST OF 2x12 FLOOR JOISTS AT 12" O.C. AS SHOWN ON PLAN. 2ND FLOOR LEGEND 1.WOOD LEDGER FOR TRUSS/JOISTS OR SHEATHING BEARING. SEE LEDGER SCHEDULE FOR SIZE AND CONNECTION REQUIREMENTS. 2. WOOD CONNECTOR OR FASTENERS. TRIM OR SHIM AS REQUIRED (34" EACH SIDE MAX.) FOR SNUG FITTING CONNECTION. IF CONNECTOR SIZE IS NOT SHOWN, SIZE SHALL BE BASED ON MEMBER SIZES SHOWN ON PLAN. EE = EACH END, ES = EACH SIDE. 3. STRUCTURAL THRU COLUMN. SEE COLUMN SCHEDULE FOR SIZE, MATERIAL, AND REQUIREMENTS. 3.1. COLUMN BELOW. 3.2. COLUMN ABOVE. 4.SECTION MARK AT THIS LOCATION IS A SIMILAR CONDITION WITH MINOR DIFFERENCES TO SECTION DRAWN. (#)-X#X# ?? ?? ?? (SIM.) A 2"SPACING IN TABLE 3" TO 6"2"3"LEDGER/NAILER SCHEDULE MARK PLYS & NOM. SIZE (INCH) CONNECTING MATERIAL 1. ALL LEDGERS AND NAILERS ARE ARE SOUTHERN PINE No.2 GRADE U.N.O. 2. LEDGERS AND NAILERS SHALL BE PRESSURE TREATED WHEN IN CONTACT WITH CONCRETE/C.M.U. 3. ROWS OF FASTENERS SHALL BE STAGGERED BY SPACING LISTED IN TABLE UNLESS ATTACHING TO STUDS OR TRUSSES OR OTHERWISE NOTED. 4. SEE DIAGRAM BELOW FOR ADDITIONAL REQUIREMENTS. 5. ROOF LEDGERS SHALL MATCH TOP OF TRUSS/RAFTER ELEVATION AND FOLLOW ROOF SLOPE. QNTY/SIZE/TYPE/SPACING OF FASTENERS OR ANCHORS SPECIFIC NOTES MIN.2x12 EACH FLOOR TRUSS/ WALL STUD. A (4) SDWS22400DB AT 24" O.C. MAX. SCALE: B1 S200 SECTION WOOD BEAM, SEE PLANS FOR SIZE. 2x JOISTS. SEE W.C.S. FOR UPLIFT CONNECTOR. 2x12 CONT. RIM BOARD. SEE W.C.S. FOR ATTACHMENT REQUIREMENTS. PROVIDE FULL DEPTH BLOCKING. ATTACH TO BEAM BELOW w/ 0.131"x3" TOENAILS @ 3" O.C. AND (3) 0.131"x3" TOENAILS E.S. TO ADJACENT JOIST. WOOD CONNECTOR SCHEDULE: 1. FLOOR JOISTS: 1.1. TO BEAM BELOW - (1) H2.5A OR (1) SDWC15600 SCREW 1.2. TO FACE OF BEAM/LEDGER - LUS212 2. RIM BOARD: 2.1. TO EACH JOIST - (5) 16d ENDNAILS (E.S.) W.C.S. SCALE: F1 S200 SECTION WALKERRESIDENCE337 4TH ST.ATLANTIC BEACH,FL 32233REV/DATE/DESCRIPTION SHEET TITLE SHEET NUMBER FOUNDATION AND SECOND LEVEL BALCONY PLAN S200 FOUNDATION PLAN SECOND LEVEL BALCONY PLAN Scale:1/4" = 1'-0" Scale:1/4" = 1'-0" By Toni Gindlesperger at 11:42 am, Nov 09, 2023 By Brian Broedell at 9:47 am, Nov 13, 2023