ABCC P2 - Bldg 2 - E0.1_1SPRINKLER SYSTEM FLOW SWITCH. PROVIDE FIRE ALARM MONITOR MODULE AND COORDINATE INSTALLATION AND CONNECTION WITH THE SPRINKLER CONTRACTOR. FIRE ALARM HEAT DETECTOR. COMBINATION FIXED TEMPERATURE/RATE OF RISE. CEILING MOUNT AT LOCATION SHOWN UNLESS OTHERWISE NOTED. FIRE ALARM PHOTOELECTRIC SMOKE DETECTOR. CEILING MOUNT AT LOCATION SHOWN UNLESS OTHERWISE NOTED. FIRE ALARM DUCT SMOKE DETECTOR. ELECTRICAL CONTRACTOR SHALL FURNISH THE DETECTOR, THE MECHANICAL CONTRACTOR SHALL INSTALL IN THE DUCTWORK, AND THE ELECTRICAL CONTRACTOR SHALL CONNECT TO THE FIRE ALARM. FIRE ALARM ANNUNCIATOR PANEL. FIRE ALARM CONTROL PANEL. FIRE ALARM WALL-MOUNTED MAGNETIC DOOR HOLDER. COORDINATE INSTALLATION WITH DOOR INSTALLER. FIRE ALARM PULL STATION. MOUNT MOUNT SUCH THAT OPERABLE PART OF THE DEVICE IS NO LESS THAN 42" ABOVE FINISHED FLOOR OR GREATER THAN 48" ABOVE FINISHED FLOOR. HEIGHT MEASURED TO CENTERLINE OF DEVICE. FIRE ALARM STROBE ONLY. MOUNT SUCH THAT ENTIRE LENS IS NO LESS THAN 80" ABOVE FINISHED FLOOR OR GREATER THAN 96" ABOVE FINISHED FLOOR. 15/75 CANDELA IN OFFICES. FIRE ALARM HORN/STROBE. MOUNT SUCH THAT ENTIRE LENS IS NO LESS THAN 80" ABOVE FINISHED FLOOR OR GREATER THAN 96" ABOVE FINISHED FLOOR. 15/75 CANDELA IN OFFICES. "S" = SPEAKER HORN STROBE, "F" = HORN STROBE. INTERCOM SPEAKERS. OWNER PROVIDED AND INSTALLER DEVICES. CONTRACTOR SHALL PROVIDE 2 DATA DROPS AND ASSOCIATED CABLING TO LOCATIONS AS SHOWN ON DRAWINGS. COORDINATE MOUNTING HARDWARE PRIOR TO INSTALLATION. SECURITY CAMERA. CONTRACTOR SHALL PROVIDE 2 DATA NETWORK DROPS AND ASSOCIATED CABLING AT EACH LOCATION. COORDINATE WITH OWNER AND SECURITY INSTALLER. SPRINKLER SYSTEM TAMPER SWITCH. PROVIDE FIRE ALARM MONITOR MODULE AND COORDINATE INSTALLATION AND CONNECTION WITH THE SPRINKLER CONTRACTOR. FIRE ALARM CARBON MONOXIDE DETECTOR. CEILING/PENDANT MOUNT AT LOCATION SHOWN UNLESS OTHERWISE NOTED. WIRELESS ACCESS POINT. OWNER PROVIDED AND INSTALLER DEVICES. CONTRACTOR SHALL PROVIDE A DATA DROP AND ASSOCIATED CABLING TO LOCATIONS AS SHOWN ON DRAWINGS. COORDINATE MOUNTING HARDWARE PRIOR TO INSTALLATION. SPECIFICATIONS A. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT FOR COMPLETE ELECTRICAL INSTALLATION. B. ALL WORK SHALL CONFORM TO REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE AND APPLICABLE STATE AND LOCAL CODES. C. WORKMANSHIP SHALL BE FIRST QUALITY AND IN ACCORDANCE WITH BEST PRACTICES OF THE TRADE BY SKILLED WORKERS. D. LOCATIONS SHOWN ARE APPROXIMATE. CONTRACTOR SHALL COORDINATE ACTUAL LOCATIONS WITH OTHER TRADES. E. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL FEES AND PERMITS REQUIRED AND SHALL FURNISH CERTIFICATION OF INSPECTION TO OWNER AT THE COMPLETION OF PROJECT. F. ALL MATERIAL SHALL BE NEW AND UL APPROVED AND LABELED. G. UNLESS OTHERWISE NOTED, CONDUIT BELOW SLAB OR GRADE SHALL BE MINIMUM 3/4" RIGID CONDUIT OR PVC. EXTERIOR CONDUIT ABOVE GRADE SHALL BE MINIMUM 1/2" RIGID OR IMC. WHERE CONDUIT TRANSITIONS FROM BELOW SLAB OR GRADE TO ABOVE SLAB OR GRADE, PROVIDE RIGID ELBOWS AND RIGID NIPPLES. FLEXIBLE METAL CONDUIT SHALL BE USED FOR CONNECTIONS TO LIGHT FIXTURES (NO LONGER THAN 6-FEET) OR FOR CONNECTION TO VIBRATING EQUIPMENT SUCH AS MOTORS OR TRANSFORMERS (NO LONGER THAN 3-FEET). WHERE INSTALLED OUTSIDE OR IN AREAS SUBJECT TO WATER, PROVIDE LIQUID-TIGHT FLEXIBLE METAL CONDUIT. H. UNLESS OTHERWISE NOTED, ALL CONDUCTORS SHALL BE TYPE THHN/THWN COPPER, SOLID FOR #10 OR SMALLER, STRANDED FOR #8 OR LARGER. CONDUCTORS #10 OR SMALLER SHALL HAVE COLORED INSULATION JACKET. MINIMUM WIRE SIZE TO BE #12 AWG. ALL WIRE SHALL BE COPPER. I. TOGGLE SWITCHES TO BE SPECIFICATION GRADE, 20A, 120-277 VAC HUBBELL CATALOG #1221, #1222, #1223, 1224 (OR EQUIVALENT) WITH THERMOPLASTIC DEVICE PLATES. COLOR SHALL BE WHITE, UNLESS OTHERWISE SPECIFIED BY ARCHITECT OR INTERIOR DESIGNER. J. DUPLEX RECEPTACLES TO BE SPECIFICATION GRADE, 20A, 120V HUBBELL CATALOG #5262 AND #GF5262 (OR EQUIVALENT) WITH THERMOPLASTIC WHITE DEVICE PLATES. K. WALL BOX DIMMERS SHALL BE LUTRON NOVA T OR APPROVED EQUIVALENT. PROVIDE DIMMER TYPE TO MATCH THE TYPE OF LOAD BEING CONTROLLED. L. WALL BOX OCCUPANCY SENSORS SHALL BE WATTSTOPPER DW-100 DUAL TECHNOLOGY SENSORS OR APPROVED EQUIVALENT. SET TIMER TO 15-MINUTES UNLESS OTHERWISE NOTED. M. CEILING-MOUNTED OCCUPANCY SENSORS SHALL BE WATTSTOPPER DT-300 DUAL TECHNOLOGY SENSORS. PROVIDE MANUFACTURER'S SUGGESTED POWER PACK BASED UPON LOADS BEING SERVED AND THE NUMBER OF OCCUPANCY SENSORS CONNECTED TO EACH POWER PACK. SET TIMER TO 15-MINUTES UNLESS OTHERWISE NOTED. N. ALL DEVICES INSTALLED IN AREAS EXPOSED TO THE WEATHER AND WHERE SPECIFICALLY INDICATED SHALL BE FURNISHED WITH A WEATHERPROOF DEVICE PLATE. WEATHERPROOF RECEPTACLES ARE REQUIRED IN EXTERIOR LOCATIONS. O. LIGHTING FIXTURES AND LAMPS TO BE FURNISHED AND INSTALLED AS INDICATED ON THE LIGHTING FIXTURE SCHEDULE. P. DISCONNECT SWITCHES SHALL BE HEAVY DUTY TYPE, NEMA 1 FOR INDOOR, NEMA 3R FOR OUTDOOR UNLESS INDICATED OTHERWISE. Q. ALL ELECTRICAL EQUIPMENT AND SYSTEMS SHALL BE TESTED AND ADJUSTED FOR PROPER OPERATION. COMPLETED WIRING SYSTEM SHALL BE FREE OF SHORT CIRCUITS. R. GFCI RECEPTACLES SHALL NOT BE CONCEALED BEHIND EQUIPMENT SUCH AS DRINKING FOUNTAINS, VENDING MACHINES, OR ANY LIKE EQUIPMENT. S. TERMINATIONS (LUGS, TERMINAL BLOCKS, ETC.) IN CIRCUIT BREAKERS, DISCONNECT SWITCHES, LIGHTING CONTACTOR, RELAYS, PANELBOARDS, TIME SWITCHES, ETC. SHALL BE RATED FOR 75 DEGREES C IN TEMPERATURE. IF TERMINATIONS IN EQUIPMENT SUCH AS EXHAUST FANS, WATER HEATERS, AIR CONDITIONING UNITS, ETC., ARE RATED FOR 60 C ONLY, THEN CONDUCTORS MUST BE DE-RATED AND USED IN COMPLIANCE WITH TABLE 310-16 OF CURRENT NEC AND SIZED PER THE 60 DEGREES C COLUMN. EXIT SIGN, TYPE AS DESIGNATED ON PLAN. PROVIDE NUMBER OF FACES AND CHEVRONS AS INDICATED ON PLAN. REFER TO LUMINAIRE SCHEDULE. VACANCY SWITCH. PROVIDE OVERLOADS SIZED FOR ITS ASSOCIATED MOTOR. LIGHT SWITCH, "2" INDICATES 2-POLE, "3" INDICATES 3-WAY, "4" INDICATES 4-WAY, "M" INDICATES MOTOR. S S OC HOMERUN TO PANELBOARD, LETTER INDICATES PANEL DESIGNATION. NUMBER INDICATES CIRCUIT NUMBER, SLASH MARKS INDICATE NUMBER OF CONDUCTORS IN SIZE CONDUIT AS REQUIRED BY NEC. NO SLASH MARKS INDICATES 2#12 & 1#12G - 1/2"C. CONDUIT CONCEALED ABOVE CEILINGS OR WITHIN WALLS . CONDUIT CONCEALED WITHIN SLAB OR BELOW GRADE. PANELBOARD 480Y/277V OR 208Y/120V, 3 PHASE, 4 WIRE UNLESS NOTED. SEE PANEL SCHEDULES FOR REQUIREMENTS. 2X4 LUMINAIRE, TYPE AS DESIGNATED ON PLAN. REFER TO LUMINAIRE SCHEDULE. HALF SHADE DESIGNATES EMERGENCY FIXTURE. WALL MOUNTED LUMINAIRE, TYPE INDICATED. REFER TO LUMINAIRE SCHEDULE. RECESSED CAN LUMINAIRE, TYPE INDICATED. REFER TO LUMINAIRE SCHEDULE. HALF SHADE DESIGNATES EMERGENCY FIXTURE. NEMA 5-20R GROUNDING DUPLEX RECEPTACLE. MOUNT AT 18" ABOVE FINISHED FLOOR. RECEPTACLE AND COVERPLATE COLOR PER SPECIFICATIONS. NEMA 5-20R GROUNDING DUPLEX RECEPTACLE. MOUNT AT 42" ABOVE FINISHED FLOOR OR 6" ABOVE COUNTERTOP. RECEPTACLE AND COVERPLATE COLOR PER SPECIFICATIONS. NEMA 5-20R GROUNDING DUPLEX RECEPTACLE WITH 5 mA INTEGRAL GROUND FAULT SENSING DEVICE. MOUNT AT 18" ABOVE FINISHED FLOOR. (2) NEMA 5-20R GROUND DUPLEX RECEPTACLES WITHIN A SINGLE 2-GANG COVER PLATE. MOUNT AT 18" ABOVE FINISHED FLOOR. RECEPTACLES AND COVERPLATE COLORS PER SPECIFICATIONS. SPECIAL RECEPTACLE, NEMA 6-30R UNLESS NOTED OTHERWISE. MOUNT AS REQUIRED FOR APPLIANCE. RECEPTACLE AND COVERPLATE COLOR PER SPECIFICATIONS. TELEPHONE OUTLET. PROVIDE JUNCTION BOX AT 18" AFF. PROVIDE 3/4" CONDUIT FROM TELEPHONE BACKBAORD TO LOCATION SHOWN WITH FACEPLATE. ELECTRICAL LEGEND MOTOR CONNECTION. NUMBER INDICATES HORSEPOWER RATING. HEIGHT FIRE ALARM CONTROL PANEL ABBREVIATIONS JUNCTION BOX THOUSAND CIRCULAR MILS KILOVOLT-AMPERES LIGHT EMITTING DIODE MAIN CIRCUIT BREAKER MINIMUM GALVANIZED RIGID CONDUIT HIGH INTENSITY DISCHARGE KILO-AMPERES FIRE ALARM GROUND MOUNTING MAIN LUG ONLY GRC ABOVE FINISHED FLOORAFF AFG AIC DIA AWG CU CKT BKR AT EXP ELEC AMPERE INTERRUPTING CAPACITY CIRCUIT DIAMETER EXPLOSION-PROOF ELECTRIC, ELECTRICAL COPPER ABOVE FINISHED GRADE BREAKER AMERICAN WIRE GAUGE CONDUIT, CONDUCTOR AMPERE TRIP C LED MIN MCB MTG MLO HID HT KA KVA KCMIL JB AF AC AMPERE FRAME ALTERNATING CURRENT AMPEREA FA FACP GND PHASEPH RIGID GALVANIZED STEEL UNLESS NOTED OTHERWISE POLYVINYL CHLORIDE VOLTSV WATTS, WIRE VOLT-AMPERES TRANSFORMER W VA AND& XFMR PANEL TYPICAL UNDERGROUND PVC PNL UNO TYP UG RGS NEUTRAL POLE PUSH-BUTTON NEUT P PB NEMA 5-20R GROUNDING DUPLEX RECEPTACLE WITH 5mA INTEGRAL GROUND FAULT SENSING DEVICE. PROVIDE TAYMAC STANDARD CLEAR COVER WHICH MAINTAINS WEATHERPROOF RATING WHILE PLUG IS INSERTED. MOUNT AT 18" ABOVE FINISHED FLOOR. 1X4 LUMINAIRE, TYPE AS DESIGNATED ON PLAN. REFER TO LUMINAIRE SCHEDULE. HALF SHADE DESIGNATES EMERGENCY FIXTURE. 2X2 LUMINAIRE, TYPE AS DESIGNATED ON PLAN. REFER TO LUMINAIRE SCHEDULE. HALF SHADE DESIGNATES EMERGENCY FIXTURE. FLOOR BOX WITH INTEGRAL POWER & DATA COMPARTMENTS. PROVIDE ALL REQUIRED ACCOUTREMENT. ROUTE 1" CONDUIT FROM DATA SECTION TO ABOVE CEILING. COORDINATE CONDUIT SIZE AND CABLING REQUIREMENTS WITH CABLING PLANT DRAWINGS AND INSTALLATION DESIGN PLANS. RAISED FLOOR FIRE RATED B.O.D. LEGRAND #AC8850, FIRE RATED BOX B.O.D. IS LEGRAND #EVOLUTION SERIES, CONCRETE POUR RATED B.O.D. WIREMOLD RFB4. SUBSCRIPT INDICATES QUANTITY OF DATA JACKS AND CABLING. FUSED DISCONNECT SWITCH (NEMA 1 ENCLOSURE UNLESS OTHERWISE NOTED) DESIGNATED AS FOLLOWS: A=SWITCH SIZE, B=FUSE SIZE, C=POLES, D=NEMA TYPE.A/B/C/DF LIGHTSLTS RECEPTACLEREC NEMA 5-20R GROUNDING DUPLEX RECEPTACLE CONTROLLED BY WALL SWITCH. MOUNT AT 18" ABOVE FINISHED FLOOR. RECEPTACLE AND COVERPLATE COLOR PER SPECIFICATIONS. NEMA 5-20R GROUNDING DUPLEX RECEPTACLE WITH 5 mA INTEGRAL GROUND FAULT SENSING DEVICE. MOUNT AT 42" ABOVE FINISHED FLOOR OR 6" ABOVE COUNTERTOP. STRIP LIGHT FIXTURE, TYPE AS DESIGNATED ON PLAN. REFER TO LIGHT FIXTURE SCHEDULE. HALF SHADE DESIGNATES EMERGENCY FIXTURE. 1/4 PARKING/AREA POLE LIGHT FIXTURE, TYPE AS DESIGNATED ON PLAN. REFER TO LIGHT FIXTURE SCHEDULE. ELECTRICAL GENERAL NOTES 1. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN FOR THE EXACT LOCATION OF ALL LUMINARIES 2. THE FINAL AIMING OF ALL ADJUSTABLE LUMINARIES SHALL BE AS DIRECTED BY THE ARCHITECT. 3. REFER TO THE RISER DIAGRAM FOR FEEDER SIZES FOR PANELBOARDS. 4. THE OVERCURRENT PROTECTION, WIRE SIZE AND NUMBER OF CONNECTION POINTS FOR MECHANICAL HVAC EQUIPMENT IS FOR ITEMS AS SPECIFIED. COORDINATE WITH THE MECHANICAL CONTRACTOR AND MAKE NECESSARY CHANGES PRIOR TO INSTALLATION FOR ACTUAL EQUIPMENT FURNISHED AT NO COST TO THE OWNER. REFER TO THE MECHANICAL DRAWINGS FOR THE EXACT LOCATIONS OF MECHANICAL EQUIPMENT. 5. ALL RECEPTACLES WITHIN SIX (6) FEET OF PLUMBING FIXTURES (IN ANY DIRECTION) SHALL BE PROVIDED WITH 5 MILLIAMP GROUND FAULT INTERRUPTERS. 6. THE EDGE OF LIGHT SWITCH WALL PLATE SHALL BE NOT MORE THAN 4" AWAY FROM METAL/WOOD DOOR FRAME. THIS IS TYPICAL FOR SINGLE OR MULTIPLE WALL SWITCHES. 7. CONFIRM THE MOUNTING HEIGHTS AND COORDINATE THE LOCATION OF ALL RECEPTACLES, OUTLETS, SWITCHES AND OTHER DEVICES WITH THE ARCHITECTURAL ELEVATIONS (FURNITURE LAYOUT) PRIOR TO ROUGH-IN. 8. PROVIDE FIRE-RATED SEALS OR CAULK FOR ALL CONDUIT PENETRATIONS THROUGH FIRE-RATED WALLS AND CEILINGS. RATING TO MATCH OR EXCEED WALL FIRE RATING. 9. THERE SHALL BE NO BACK-TO-BACK RECEPTACLES IN FIRE-RATED WALLS OR SECURED WALLS. 10. TYPE "MC" CABLE WILL BE ALLOWED FOR BRANCH CIRCUITS WHERE COMPLETELY CONCEALED IN WALLS AND WITHIN GENERAL AREAS. ALL OTHER WIRING SHALL BE IN METAL CONDUIT. 11. PROVIDE GROUND CONDUCTOR IN ALL BRANCH CIRCUIT CONDUITS WITH EQUIPMENT GROUND CONDUCTOR SIZED PER NEC ARTICLE 250. 12. WHERE CONDUCTOR SIZES ARE NOT SHOWN ON DRAWINGS, BRANCH CIRCUIT CONDUCTORS SHALL NOT BE SMALLER THAN NO. 12 AND WHERE BRANCH CIRCUIT CONDUCTOR RUNS FROM THE SOURCE (PANEL) TO THE LAST DEVICE ON THE CIRCUIT EXCEEDS 100 FEET IN LENGTH, THE CONDUCTORS SHALL BE NO 10 MINIMUM FOR THE ENTIRE CIRCUIT. FOR RUNS OVER 200 FEET IN LENGTH, THE CONDUCTOR SHALL BE NO. 8 MINIMUM FOR THE ENTIRE CIRCUIT LENGTH. THE ABOVE APPLIES TO 120 VOLT CIRCUITS ONLY. 13. NO SUBSTITUTIONS PERMITTED, UNLESS IF APPROVED BY GTP CONSULTING ENGINEERS IN WRITING 10 BUSINESS DAYS PRIOR TO BID DATE. 14. NOT USED. 15. THE DEPTH OF THE WORKING SPACE IN THE DIRECTION OF LIVE PARTS SHALL BE IN ACCORDANCE WITH DISTANCES SPECIFIED IN NEC 2017 ARTICLE 110.26. 16. ELECTRICAL EQUIPMENT AND CONDUCTORS SHALL BE READILY ACCESSIBLE AND SHALL NOT BE LOCATED IN AREAS SUBJECT TO DETERIORATION DUE TO MOISTURE, EXCESSIVE TEMPERATURE, GASES, FUMES, VAPORS, LIQUID, OR OTHER HARMFUL AGENTS. 17. SWITCHBOARD(S) AND PANELBOARDS SHALL BE MARKED TO INDICATE WHERE THE POWER SUPPLY SOURCE IS LOCATED. 18. INDIVIDUAL SINGLE-POLE BREAKERS, WITH IDENTIFIED HANDLE TIES, SHALL BE INSTALLED AS THE PROTECTION FOR EACH UNGROUNDED CONDUCTOR OF MULTI-WIRE BRANCH CIRCUITS THAT SERVE ONLY SINGLE-PHASE LINE TO NEUTRAL LOADS. 19. GROUNDED CONDUCTOR/NEUTRAL SHALL BE PROVIDED AT THE SWITCH LOCATION FOR SWITCHES CONTROLLING LIGHTING LOADS SUPPLIED BY A GROUNDED GENERAL PURPOSE CIRCUIT. 20. GROUND FAULT PROTECTION FOR APPLIANCES SHALL BE READILY ACCESSIBLE. 21. A RECEPTACLE SHALL BE LOCATED WITHIN 50'-0" OF THE ELECTRICAL SERVICE EQUIPMENT. JUNCTION BOX WALL MOUNTED OR CEILING MOUNTED AS INDICATED ON PLAN. SIZED AS REQUIRED FOR CONDUITS AND FILL. MINIMUM 1" EMT FOR FURNITURE INSTALLATION.J FLOOR MOUNTED JUNCTION BOX AS INDICATED ON PLAN. SIZED AS REQUIRED FOR CONDUITS AND FILL.J D DEDICATED POWER E ESSENTIAL POWER UPS POWEREDU NEMA 5-20R GROUNDING DUPLEX RECEPTACLE. CELING MOUNTED. RECEPTACLE AND COVERPLATE COLOR PER SPECIFICATIONS. TV RECEPTACLE. CAT6 CABLING AND COAXIAL CABLING TO BE MOUNTED AT 84" ABOVE FINISHED FLOOR. PROVIDE CONDUIT FROM SINGLE GANG JUNCTION BOX TO 12" ABOVE CEILING. PROVIDE 3/4" CONDUIT FROM MDF ROOM TO FACEPLATE SHOWN. COORDINATE EXACT LOCATION IN FIELD WITH ARCHITECT AND FURNITURE LAYOUT. TV CEILING/PENDANT MOUNTED DUAL TECH, VACANCY SENSOR.OC J TELEPHONE/DATA OUTLET. PROVIDE JUNCTION BOX AT 18" AFF. PROVIDE 3/4" CONDUIT FROM TELEPHONE BACKBAORD TO LOCATION SHOWN WITH FACEPLATE. SUBSCRIPT INDICATES QUANTITY OF DATA JACKS AND CABLING. (2) NEMA 5-20R GROUNDING DUPLEX RECEPTACLE WITH 5 mA INTEGRAL GROUND FAULT SENSING DEVICE. MOUNT AT 42" ABOVE FINISHED FLOOR OR 6" ABOVE COUNTERTOP. DAYLIGHT HARVESTING LIGHT SENSOR.DL FIRE ALARM ANNUNCIATOR PANELFAAP GENERATOR ANNUNCIATOR PANELGAP LIGHTING CONTROL PANEL. SEE SPECIFICATIONS FOR BASIS OF DESIGN.LCP_ F DH R/F FS FACP FAA S S SS TS CO AP LIGHT FIXTURE SCHEDULE TYPE MANUFACTURERDESCRIPTION CATALOG NUMBER LAMPS & WATTAGE VOLTAGE REMARKSMOUNTING OA F EXTERIOR GRADE BEAM MOUNTED LED SCONCE LITHONIA 1X4 LED GASKETED, STRIP UTILITY FIXTURE SURFACELITHONIA20W LED 120V 120V40W LED TO BE SELECTED BY OTHERS TO BE SELECTED BY OTHERS SURFACE PROFESSIONA L E N GIN EERNo. 85909WILLIAMS.GADD Y J R. STATE OF L I C ENSE FLOR I D A DRAWN BY: PROJECT NO.: SCALE: REVISION NO.DATE DESCRIPTION THE INFORMATION SHOWN ON THESE DRAWINGS IS OWNED BY AND IS THE PROPERTY OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. NO PART THEREOF SHALL BE COPIED, ADAPTED, OR DISTRIBUTED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. COPYRIGHT © 2023 26560 AGOURA ROAD, SUITE 106 CALABASAS, CA 91302 310.670.9144 A S S O C I A T E S ARCHITECTS + ENGINEERS S H E P P H I R D will.s@shep-ae.com 1 12-02-22 SD PRICING 2 2-10-23 DD PRICING 3 9-07-23 PHASE 2 90% CD Atlantic Beach Country Club Phase 2 Construction Documents 1600 Selva Marina Drive Atlantic Beach, FL 32233 2-E0.1ELECTRICAL COVER SHEET2022-352 Author 1 1 07-14-23 ADDENDUM#1