ABCC P2 - Bldg 2 - E4.0_1= FIRE ALARM SYSTEMFAS - FIRE ALARM SYSTEM - 120/208V RED BLACK USE THE FOLLOWING COLOR CODE: - FAS - PANELBOARD & CIRCUIT # USE A BLACK MARKER IN THIS SPACE TO IDENTIFY THE ONE THAT APPLIES:LA-1 ENCASE RECEPTACLE JUNCTION BOX ON ALL SIDES WITH UL LISTED FIRE-RATED "PUTTY PACK". TYPICAL FOR ALL BACK-TO-BACK RECEPTACLES IN FIRE RATED WALLS THAT ARE LESS THAN 24" ON CENTER. LESS THAN 24" APART RECEPTACLE COVER PLATE JUNCTION BOX BOTH NEUTRAL AND PHASE CONDUCTOR SHALL BE INSTALLED AS SHOWN. DO NOT USE DEVICES AS FEED THROUGH TO OTHER DEVICES LUG ON BOX. TO GROUND NOTE: NEUTRAL OR PHASE CONDUCTOR RECEPTACLE L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT F RATINGS - 1 AND 2 HR (SEE ITEMS 1 AND 3) A A SECTION A-A 2 1B L RATING AT 400F - 4 CFM/SQ FT T RATING - 0 HR 3 SYSTEM NO. W-L-1054 1A 1 WALL ASSEMBLY -- THE 1 OR 2 HR FIRE-RATED GYPSUM WALLBOARD/ STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS -- WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC. STEEL STUDS TO BE MIN 2-1/2 IN. WIDE AND SPACED MAX 24 IN. OC. WHEN STEEL STUDS ARE USED AND THE DIAM OF OPENING EXCEEDS THE WIDTH OF STUD CAVITY, THE OPENING SHALL BE FRAMED ON ALL SIDES USING LENGTHS OF STEEL STUD INSTALLED BETWEEN THE STUD CAVITY, THE OPENING SHALL BE FRAMED ON ALL SIDES USING LENGTHS OF STEEL STUD INSTALLED BETWEEN THE VERTICAL STUDS AND SCREW-ATTACHED TO THE STEEL STUDS AT EACH END. THE FRAMED OPENING IN THE WALL SHALL BE 4 TO 6 IN. WIDER AND 4 TO 6 IN. HIGHER THAN THE DIAM OF THE PENETRATING ITEM SUCH THAT, WHEN THE PENETRATING ITEM IS INSTALLED IN THE OPENING, A 2 TO 3 IN. CLEARANCE IS PRESENT BETWEEN THE PENETRATING ITEM AND THE FRAMING ON ALL FOUR SIDES. B. GYPSUM BOARD* -- 5/8 IN. THICK, 4 FT WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM BOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM OF OPENING IS 32-1/4 IN. FOR STEEL STUD WALLS. MAX DIAM OF OPENING IS 14-1/2 IN. FOR WOOD STUD WALLS.THE F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE FIRE RATING OF THE WALL ASSEMBLY. 2 THROUGH-PENETRANTS -- ONE METALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE SHALL BE MIN 0 IN. TO MAX 2-1/4 IN. PIPE MAY BE INSTALLED WITH CONTINUOUS POINT CONTACT. PIPE, CONDUIT OR TUBING MAY BE INSTALLED AT AN ANGLE NOT GREATER THAN 45 DEGREES FROM PERPENDICULAR. PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED: A. STEEL PIPE -- NOM 30 IN DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE. B. IRON PIPE -- NOM 30 IN. DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. C. CONDUIT -- NOM 4 IN DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING OR 6 IN. DIAM STEEL CONDUIT. D. COPPER TUBING -- NOM 6 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. E. COPPER PIPE -- NOM 6 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. 3 FILL, VOID OR CAVITY MATERIAL* -- SEALANT -- MIN 5/8 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. AT THE POINT OR CONTINUOUS CONTACT LOCATIONS BETWEEN PIPE AND WALL, A MIN 1/2 IN. DIAM BEAD OF FILL MATERIAL SHALL BE APPLIED AT THE PIPE WALL INTERFACE ON BOTH SURFACES OF WALL. SCALE: JUNCTION BOX COVER PLATE DETAIL NOT TO SCALE BACK-TO-BACK RECEPTACLES IN FIRE RATED WALL TYPICAL MULTI-WIRE BRANCH CIRCUIT RECEPTACLE DETAIL TYPICAL CONDUIT PENETRATION THROUGH FIRE-RATED WALL 5 3 4 1 SCALE:NOT TO SCALE SCALE:NOT TO SCALE SCALE:NOT TO SCALE - CATV - CABLE TV SYSTEMGREEN - INTERCOM SYSTEMBLUE = CABLE TV SYSTEMCATV 2-E4.0 NEW ELECTRICAL RISER DIAGRAM - PHASE 12 SCALE:NOT TO SCALE 2-E4.0 2-E4.0 2-E4.0 2-E4.0 ONE-LINE KEYED NOTES (THIS RISER DIAGRAM ONLY) CONDUCTOR SCHEDULE (THIS DRAWING ONLY) ONE-LINE GENERAL NOTES (THIS RISER DIAGRAM ONLY) NEW ELECTRICAL SERVICE AND PANELBOARD. BOND NEUTRAL AND GROUND TOGETHER. PROVIDE #3/0 BARE COPPER CABLE BONDED TO THE FOLLOWING: BUILDING WATER LINE, 40' OF 1/2" REBAR WITHIN EXTERIOR FOUNDATION FOOTER, TWO GROUND RODS SPACED 10'-0" APART, AND BUILDING STEEL. TENNIS PAVILION PANEL TP 225A MCB 208Y/120V 3 , 4W ROOF 1ST FLOOR YOUTH PAVILION PANEL YP 60A MCB 208Y/120V 3 , 4W ROOF 1 1TRANSFORMER COMPANY UTILITY NEW 1 TAG CONDUIT AND CONDUCTORS 4#4/0 & 1#4G IN 2-1/2"C 4#4 & 1#10G IN 1-1/4"C 1 2 3 #3/0 IN 2"C1 2 33 A. REFER TO ELECTRICAL SITE PLAN FOR ADDITIONAL INFORMATION.PROFESSIONA L E N GIN EERNo. 85909WILLIAMS.GADD Y J R. STATE OF L I C ENSE FLOR I D A DRAWN BY: PROJECT NO.: SCALE: REVISION NO.DATE DESCRIPTION THE INFORMATION SHOWN ON THESE DRAWINGS IS OWNED BY AND IS THE PROPERTY OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. NO PART THEREOF SHALL BE COPIED, ADAPTED, OR DISTRIBUTED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. COPYRIGHT © 2023 26560 AGOURA ROAD, SUITE 106 CALABASAS, CA 91302 310.670.9144 A S S O C I A T E S ARCHITECTS + ENGINEERS S H E P P H I R D will.s@shep-ae.com 1 12-02-22 SD PRICING 2 2-10-23 DD PRICING 3 9-07-23 PHASE 2 90% CD Atlantic Beach Country Club Phase 2 Construction Documents 1600 Selva Marina Drive Atlantic Beach, FL 32233 2-E4.0YOUTH PAVILION & SHED PANEL SCHEDULES2022-352 AJS Notes: Total Est. Demand Current:10 A Receptacle 1260 VA 100.00% 1260 VA Total Conn. Current:9 A Power 1000 VA 100.00% 1000 VA Total Est. Demand:3531 VA Other 0 VA 0.00% 0 VA Total Conn. Load:3277 VA Lighting 1017 VA 125.00% 1271 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:13 A 6 A 8 A Total Load:1540 VA 777 VA 960 VA 29 Space -- 1 -- -- 1 -- Space 30 27 Space -- 1 -- -- 1 -- Space 28 25 Space -- 1 -- -- 1 -- Space 26 23 Space -- 1 -- -- 1 -- Space 24 21 Space -- 1 -- -- 1 -- Space 22 19 Space -- 1 -- -- 1 -- Space 20 17 Space -- 1 -- -- 1 -- Space 18 15 Space -- 1 -- -- 1 -- Space 16 13 Spare 20 A 1 0 VA -- 1 -- Space 14 11 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 12 9 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 10 7 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 8 5 Lighting - Pavilion Lights & Fans 20 A 1 960 VA 0 VA 1 20 A Spare 6 3 Receptacles - Youth Pavilion 20 A 1 720 VA 57 VA 1 20 A Lighting - Storage Shed 4 1 Power - Motorized Blinds Pavilion 20 A 1 1000 VA 540 VA 1 20 A Receptacles - Storage Shed 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes: Enclosure:Type 3R MCB Rating:60 A Mounting:Surface Wires:4 Mains Rating:60 A Supply From: Phases:3 Mains Type:MCB Location: Volts:120/208 Wye A.I.C. Rating: Branch Panel: YP 1 1 1 07-14-23 ADDENDUM#1