Loading...
ABCC P2 - Bldg 1 - 0-A0.51_1CERAMIC WALL TILE BOTH SIDES CEMENTIOUS BACKING BOARD, BOTH SIDES 2x6 WOOD STUD SPACING PER STRUCTURAL INTERIORINTERIOR BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. CERAMIC WALL TILE CEMENTIOUS BACKING BOARD, BOTH SIDES 2x4 WOOD STUD SPACING PER STRUCTURAL INTERIORINTERIOR BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. CERAMIC WALL TILE CEMENTIOUS BACKING BOARD, BOTH SIDES 2x8 WOOD STUD SPACING PER STRUCTURAL INTERIORINTERIOR BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. 2x4 WOOD STUDS SPACING PER STRUCTURAL CERAMIC WALL TILE CEMENTIOUS BACKING BOARD GWB BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. INTERIORINTERIOR 2x6 WOOD STUDS SPACING PER STRUCTURAL CERAMIC WALL TILE CEMENTIOUS BACKING BOARD GWB BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. INTERIORINTERIOR 2x8 WOOD STUDS SPACING PER STRUCTURAL GWB CERAMIC WALL TILE CEMENTIOUS BACKING BOARD INTERIORINTERIOR BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. 2x4 WOOD STUDS SPACING PER STRUCTURAL BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. GWB F.C. SHINGLE PANEL SIDING COMPOSITE WOOD SHEATHING EXTERIORINTERIOR NOTE: IF PLYWOOD IS USED IN LIEU OF COMPOSITE WOOD SHEATHING, THEN PROVIDE SEPARATE WEATHER RESISTIVE BARRIER INSTALLED IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS 1 2x6 WOOD STUDS SPACING PER STRUCTURAL BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. GWB F.C. SHINGLE PANEL SIDING COMPOSITE WOOD SHEATHING EXTERIORINTERIOR NOTE: IF PLYWOOD IS USED IN LIEU OF COMPOSITE WOOD SHEATHING, THEN PROVIDE SEPARATE WEATHER RESISTIVE BARRIER INSTALLED IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS 1 2x8 WOOD STUDS SPACING PER STRUCTURAL BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. GWB F.C. SHINGLE PANEL SIDING COMPOSITE WOOD SHEATHING EXTERIORINTERIOR NOTE: IF PLYWOOD IS USED IN LIEU OF COMPOSITE WOOD SHEATHING, THEN PROVIDE SEPARATE WEATHER RESISTIVE BARRIER INSTALLED IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS 1 2x6 WOOD STUDS SPACING PER STRUCTURAL BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. GWB F.C. SHINGLE PANEL SIDING COMPOSITE WOOD SHEATHING EXTERIORINTERIOR SHEATHING PER STRUCTURAL (WHERE OCCURS) NOTE: IF PLYWOOD IS USED IN LIEU OF COMPOSITE WOOD SHEATHING, THEN PROVIDE SEPARATE WEATHER RESISTIVE BARRIER INSTALLED IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS 1 BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. COMPOSITE WOOD SHEATHING 2" AIR GAP FULL BRICK MORTAR 2x8 WOOD STUDS SPACING PER STRUCTURAL SHEATHING PER STRUCTURAL (WHERE OCCURS) EXTERIORINTERIOR NOTE: IF PLYWOOD IS USED IN LIEU OF COMPOSITE WOOD SHEATHING, THEN PROVIDE SEPARATE WEATHER RESISTIVE BARRIER INSTALLED IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS 1 THIN BRICK VENEER COMPOSITE WOOD SHEATHING THINSET ADHESIVE CEMENT BOARD DRAINAGE MAT COMPOSITE WOOD SHEATHING 2" AIR GAP FULL BRICK MORTAR 2x4 WOOD STUDS SPACING PER STRUCTURAL EXTERIORINTERIOR NOTE: IF PLYWOOD IS USED IN LIEU OF COMPOSITE WOOD SHEATHING, THEN PROVIDE SEPARATE WEATHER RESISTIVE BARRIER INSTALLED IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS 1 DRAWN BY: PROJECT NO.: SCALE: REVISION NO.DATE DESCRIPTION THE INFORMATION SHOWN ON THESE DRAWINGS IS OWNED BY AND IS THE PROPERTY OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. NO PART THEREOF SHALL BE COPIED, ADAPTED, OR DISTRIBUTED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. COPYRIGHT © 2023 26560 AGOURA ROAD, SUITE 106 CALABASAS, CA 91302 310.670.9144 A S S O C I A T E S ARCHITECTS + ENGINEERS S H E P P H I R D will.s@shep-ae.com 1 12-02-22 SD PRICING 2 2-10-23 DD PRICING 3 9-07-23 PHASE 2 90% CD Atlantic Beach Country Club Phase 2 Construction Documents 1600 Selva Marina Drive Atlantic Beach, FL 32233 3" = 1'-0"9/7/2023 5:51:21 PM Autodesk Docs://2022-352 ABCC/R22_ABCC_BLDG1_ARCH.rvt0-A0.51WALL TYPES2022-352 WRS / MW / MJ / NY SCALE:0 1 2 4 8INCHES 3" = 1'-0" 11 WALL TYPE B05 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 10 WALL TYPE B04 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 12 WALL TYPE B06 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 7 WALL TYPE B01 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 8 WALL TYPE B02 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 9 WALL TYPE B03 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 1 WALL TYPE A30 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 2 WALL TYPE A31 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 3 WALL TYPE A32 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 4 WALL TYPE A33 0 2 4 8 16FEET 1/8" = 1'-0" SCALE:5 WALL TYPE A35 0 2 4 8 16FEET 1/8" = 1'-0" SCALE:6 WALL TYPE A36 1 7/14/23 ADDENDUM#1