Loading...
ABCC P2 - Bldg 1 - 0-A0.52_12x6 WOOD STUDS SPACING PER STRUCTURAL BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. F.C. SHINGLE PANEL SIDING COMPOSITE WOOD SHEATHING EXTERIORINTERIOR CERAMIC WALL TILE CEMENTIOUS BACKING BOARD NOTE: IF PLYWOOD IS USED IN LIEU OF COMPOSITE WOOD SHEATHING, THEN PROVIDE SEPARATE WEATHER RESISTIVE BARRIER INSTALLED IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS 1 2x8 WOOD STUDS SPACING PER STRUCTURAL BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. F.C. SHINGLE PANEL SIDING COMPOSITE WOOD SHEATHING EXTERIORINTERIOR CERAMIC WALL TILE CEMENTIOUS BACKING BOARD NOTE: IF PLYWOOD IS USED IN LIEU OF COMPOSITE WOOD SHEATHING, THEN PROVIDE SEPARATE WEATHER RESISTIVE BARRIER INSTALLED IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS 1 FRP PANELING 2x4 WOOD STUDS SPACING PER STRUCTURAL GWB BOTH SIDES CERAMIC WALL TILE CEMENTIOUS BACKING BOARD INTERIORINTERIOR BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. INTERIORINTERIOR 2x6 WOOD STUDS SPACING PER STRUCTURAL CERAMIC WALL TILE 5/8" CEMENTIOUS BACKING BOARD GYP. WALL BOARD PLYWOOD SHEATHING PER STRUCTURAL (WHERE OCCURS) BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. 2x4 WOOD STUDS SPACING PER STRUCTURAL CERAMIC WALL TILE CEMENTIOUS BACKING BOARD GWB SHEATHING PER STRUCTURAL (WHERE OCCURS) INTERIORINTERIOR BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. 2x8 WOOD STUDS SPACING PER STRUCTURAL CERAMIC WALL TILE CEMENTIOUS BACKING BOARD GWB SHEATHING PER STRUCTURAL (WHERE OCCURS) INTERIORINTERIOR BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. 2x6 WOOD STUDS SPACING PER STRUCTURAL CERAMIC WALL TILE CEMENTIOUS BACKING BOARD GWB SHEATHING PER STRUCTURAL (WHERE OCCURS) INTERIORINTERIOR BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. 2x4 WOOD STUDS SPACING PER STRUCTURAL BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. F.C. SHINGLE PANEL SIDING COMPOSITE WOOD SHEATHING EXTERIORINTERIOR CERAMIC WALL TILE CEMENTIOUS BACKING BOARD 2x4 WOOD STUDS SPACING PER STRUCTURAL CERAMIC WALL TILE CEMENTIOUS BACKING BOARD INTERIORINTERIOR INTERIORINTERIOR 2x6 WOOD STUDS SPACING PER STRUCTURAL CERAMIC WALL TILE CERAMIC WALL TILE BOTH SIDES CEMENTIOUS BACKING BOARD, BOTH SIDES 2x8 WOOD STUD SPACING PER STRUCTURAL INTERIORINTERIOR BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. DRAWN BY: PROJECT NO.: SCALE: REVISION NO.DATE DESCRIPTION THE INFORMATION SHOWN ON THESE DRAWINGS IS OWNED BY AND IS THE PROPERTY OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. NO PART THEREOF SHALL BE COPIED, ADAPTED, OR DISTRIBUTED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. COPYRIGHT © 2023 26560 AGOURA ROAD, SUITE 106 CALABASAS, CA 91302 310.670.9144 A S S O C I A T E S ARCHITECTS + ENGINEERS S H E P P H I R D will.s@shep-ae.com 1 12-02-22 SD PRICING 2 2-10-23 DD PRICING 3 9-07-23 PHASE 2 90% CD Atlantic Beach Country Club Phase 2 Construction Documents 1600 Selva Marina Drive Atlantic Beach, FL 32233 3" = 1'-0"9/7/2023 5:51:22 PM Autodesk Docs://2022-352 ABCC/R22_ABCC_BLDG1_ARCH.rvt0-A0.52WALL TYPES2022-352 WRS / MW / MJ / NY SCALE:0 1 2 4 8INCHES 3" = 1'-0" 11 WALL TYPE B51 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 12 WALL TYPE B52 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 1 WALL TYPE B07SCALE:0 1 2 4 8INCHES 3" = 1'-0" 4 WALL TYPE B21 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 3 WALL TYPE B20 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 5 WALL TYPE B22 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 6 WALL TYPE B23 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 10 WALL TYPE B50 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 7 WALL TYPE B30 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 8 WALL TYPE B31 0 2 4 8 16FEET 1/8" = 1'-0" SCALE:2 WALL TYPE B10 1 7/14/23 ADDENDUM#1