Loading...
ABCC P2 - Bldg 1 - 0-A0.53_12x6 WOOD STUDS SPACING PER STRUCTURAL MDO PANELING BOTH SIDES 2x10 WOOD STUDS SPACING PER STRUCTURAL GWB CERAMIC WALL TILE CEMENTIOUS BACKING BOARD INTERIORINTERIOR BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. FRP PANELING 2x4 WOOD STUDS SPACING PER STRUCTURAL GWB BOTH SIDES INTERIORINTERIOR BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. FRP PANELING 2x6 WOOD STUDS SPACING PER STRUCTURAL GWB BOTH SIDES INTERIORINTERIOR BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. FRP PANELING 2x8 WOOD STUDS SPACING PER STRUCTURAL GWB BOTH SIDES INTERIORINTERIOR BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. FRP PANELING BOTH SIDES 2x4 WOOD STUDS SPACING PER STRUCTURAL GWB BOTH SIDES INTERIORINTERIOR BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. FRP PANELING BOTH SIDES 2x6 WOOD STUDS SPACING PER STRUCTURAL GWB BOTH SIDES INTERIORINTERIOR BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. COMPOSITE WOOD SHEATHING 2" AIR GAP FULL BRICK MORTAR 2x8 WOOD STUDS SPACING PER STRUCTURAL GWB SHEATHING PER STRUCTURAL (WHERE OCCURS) EXTERIORINTERIOR FRP PANELING NOTE: IF PLYWOOD IS USED IN LIEU OF COMPOSITE WOOD SHEATHING, THEN PROVIDE SEPARATE WEATHER RESISTIVE BARRIER INSTALLED IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS 1 FRP PANELING BOTH SIDES 2x8 WOOD STUDS SPACING PER STRUCTURAL GWB BOTH SIDES INTERIORINTERIOR BATT INSULATION AT SOUND WALLS WHERE OCCUR. FILL CAVITY. DRAWN BY: PROJECT NO.: SCALE: REVISION NO.DATE DESCRIPTION THE INFORMATION SHOWN ON THESE DRAWINGS IS OWNED BY AND IS THE PROPERTY OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. NO PART THEREOF SHALL BE COPIED, ADAPTED, OR DISTRIBUTED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. COPYRIGHT © 2023 26560 AGOURA ROAD, SUITE 106 CALABASAS, CA 91302 310.670.9144 A S S O C I A T E S ARCHITECTS + ENGINEERS S H E P P H I R D will.s@shep-ae.com 1 12-02-22 SD PRICING 2 2-10-23 DD PRICING 3 9-07-23 PHASE 2 90% CD Atlantic Beach Country Club Phase 2 Construction Documents 1600 Selva Marina Drive Atlantic Beach, FL 32233 3" = 1'-0"9/7/2023 5:51:23 PM Autodesk Docs://2022-352 ABCC/R22_ABCC_BLDG1_ARCH.rvt0-A0.53WALL TYPES2022-352 WRS / MW / MJ / NY SCALE:0 1 2 4 8INCHES 3" = 1'-0" 1 WALL TYPE B53 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 2 WALL TYPE B60 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 4 WALL TYPE C01 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 5 WALL TYPE C02 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 6 WALL TYPE C03 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 7 WALL TYPE C04 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 8 WALL TYPE C05 SCALE:0 1 2 4 8INCHES 3" = 1'-0" 10 WALL TYPE C22 0 2 4 8 16FEET 1/8" = 1'-0" SCALE:9 WALL TYPE C06 1 7/14/23 ADDENDUM#1