Loading...
ABCC P2 - Bldg 1 - 1-E0-1_1TVSPRINKLER SYSTEM FLOW SWITCH. PROVIDE FIRE ALARM MONITOR MODULE AND COORDINATE INSTALLATION AND CONNECTION WITH THE SPRINKLER CONTRACTOR.FIRE ALARM HEAT DETECTOR. COMBINATION FIXED TEMPERATURE/RATE OF RISE. CEILING MOUNT AT LOCATION SHOWN UNLESS OTHERWISENOTED.FIRE ALARM PHOTOELECTRIC SMOKE DETECTOR. CEILING MOUNT AT LOCATION SHOWN UNLESS OTHERWISE NOTED.FIRE ALARM DUCT SMOKE DETECTOR. ELECTRICAL CONTRACTOR SHALL FURNISH THE DETECTOR, THE MECHANICAL CONTRACTOR SHALL INSTALL IN THE DUCTWORK,AND THE ELECTRICAL CONTRACTOR SHALL CONNECT TO THE FIRE ALARM.FIRE ALARM ANNUNCIATOR PANEL.FIRE ALARM CONTROL PANEL.FIRE ALARM PULL STATION. MOUNT MOUNT SUCH THAT OPERABLE PART OF THE DEVICE IS NO LESS THAN 42" ABOVE FINISHED FLOOR OR GREATER THAN 48" ABOVEFINISHED FLOOR. HEIGHT MEASURED TO CENTERLINE OF DEVICE.FIRE ALARM STROBE ONLY. MOUNT SUCH THAT ENTIRE LENS IS NO LESS THAN 80" ABOVE FINISHED FLOOR OR GREATER THAN 96" ABOVE FINISHED FLOOR. 15/75 CANDELAIN OFFICES.FIRE ALARM HORN/STROBE. MOUNT SUCH THAT ENTIRE LENS IS NO LESS THAN 80" ABOVE FINISHED FLOOR OR GREATER THAN 96" ABOVE FINISHED FLOOR. 15/75 CANDELAIN OFFICES. "S" = SPEAKER HORN STROBE, "F" = HORN STROBE.SPRINKLER SYSTEM TAMPER SWITCH. PROVIDE FIRE ALARM MONITOR MODULE AND COORDINATE INSTALLATION AND CONNECTION WITH THE SPRINKLER CONTRACTOR.SPECIFICATIONSGENERAL NOTESFIELD VERIFY ALL EXISTING CONDITIONSCATV OUTLET. PROVIDE TWO (2) 1-GANG BOXES AT HEIGHT SPECIFIED ON ARCHITECTURAL ELEVATIONS WALL MOUNTED. ROUTE 1" CONDUITWITH PULLSTRING TO 6" ABOVE ACCESSIBLE CEILING FROM ONE OF THE BOXES. PROVIDE 20A, 120V DUPLEX RECEPTACLE IN THE SECOND BOX.COVERPLATE, CABLING, & DEVICE SHALL BE BY OTHERS. FACEPLATE COLOR (BY OTHERS) TO MATCH RECEPTACLES.1. THE WORD "PROVIDE" MEANS TO FURNISH, INSTALL, AND CONNECT WHERE USED ON THE DRAWINGS.2. REFER TO ONE-LINE DIAGRAM FOR FEEDER SIZES FOR PANELBOARDS.3. OVERCURRENT PROTECTION, WIRE SIZE AND NUMBER OF CONNECTION POINTS FOR MECHANICAL HVAC EQUIPMENT IS FOR ITEMS AS SPECIFIED.COORDINATE WITH MECHANICAL CONTRACTOR AND MAKE NECESSARY CHANGES PRIOR TO INSTALLATION FOR ACTUAL EQUIPMENT FURNISHED AT NO COSTTO OWNER. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION OF MECHANICAL EQUIPMENT. REFER TO ELECTRICAL EQUIPMENT CONNECTIONSCHEDULE.4. ALL JUNCTION BOX COVERPLATES SHALL BE LABELED. SEE DETAIL5. ALL RECEPTACLES WITHIN SIX (6) FEET OF PLUMBING FIXTURES SHALL BE PROVIDED WITH 5 MILLIAMP GROUND FAULT INTERRUPTERS.6. EDGE OF LIGHT SWITCH WALL PLATE SHALL BE NOT MORE THAN 4" AWAY FROM METAL/WOOD DOOR FRAME. TYPICAL FOR SINGLE OR MULTIPLE WALLSWITCHES.7. BRANCH CIRCUIT CONDUCTORS SHALL BE COPPER AND SHALL NOT BE SMALLER THAN NO. 12 AND WHERE BRANCH CIRCUIT CONDUCTOR RUNS FROMSOURCE (PANEL) TO THE LAST DEVICE ON THE CIRCUIT EXCEEDS 100 FEET IN LENGTH, THE CONDUCTORS SHALL BE NO. 10 MINIMUM AND FOR THE ENTIRELENGTH OF THE CIRCUIT. FOR RUNS OVER 200 FEET IN LENGTH THE CONDUCTOR SHALL BE NO. 8 MINIMUM AND FOR THE ENTIRE LENGTH OF THE CIRCUIT.THE ABOVE APPLIES TO 120 VOLT CIRCUITS ONLY.8. CONFIRM MOUNTING HEIGHTS AND COORDINATE LOCATION OF ALL OUTLETS, SWITCHES AND OTHER DEVICES WITH ARCHITECTURAL ELEVATIONS ORFURNITURE LAYOUT PRIOR TO ROUGH-IN.9. ALL MULTI-WIRE BRANCH CIRCUITS SHALL BE FED FROM BRANCH CIRCUIT BREAKERS THAT WILL SIMULTANEOUSLY DISCONNECT ALL UNGROUNDEDCONDUCTORS AT THE POWER WHERE THE BRANCH CIRCUIT ORIGINATES TO COMPLY WITH NEC 210.4(B).10. PROVIDE A NEUTRAL CONDUCTOR IN EVERY SWITCHLEG FOR CURRENT OR FUTURE USE WITH OCCUPANCY SENSORS OR DIMMER SWITCHES.11. PROVIDE SEAL FOR PENETRATION OF FIRE-RATED WALLS BY CONDUIT. SEE DETAIL. SEE ARCHITECTURAL PLAN FOR RATED WALL LOCATIONS.12. BACK-TO-BACK RECEPTACLES IN ALL ONE HOUR FIRE-RATED WALLS SHALL BE LOCATED A MINIMUM OF 24" ON CENTER. IF NOT POSSIBLE, INSTALL PERDETAIL x/Ex.x.13. PROVIDE NEW FIRE ALARM DEVICES COMPATIBLE WITH THE EXISTING FIRE ALARM SYSTEM WHERE REQUIRED. EXTEND EXISTING FIRE ALARM SYSTEMWIRING TO CONNECT NEW DEVICES. PROVIDE ADDITIONAL RELAYS, BOARDS, ETC. AS REQUIRED FOR A COMPLETE FIRE ALARM SYSTEM.14. 208/120V CONDUCTORS SHALL BE COLOR-CODED WITH JACKET OR MARKING TAPE AS FOLLOWS:PHASE A - BLACKPHASE B - REDPHASE C - BLUENEUTRAL - WHITEGROUND - GREENA. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT FOR COMPLETE ELECTRICAL INSTALLATION.B. ALL WORK SHALL CONFORM TO REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE AND APPLICABLE STATE AND LOCAL CODES.C. WORKMANSHIP SHALL BE FIRST QUALITY AND IN ACCORDANCE WITH BEST PRACTICES OF THE TRADE BY SKILLED WORKERS.D. LOCATIONS SHOWN ARE APPROXIMATE. CONTRACTOR SHALL COORDINATE ACTUAL LOCATIONS WITH OTHER TRADES.E. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL FEES AND PERMITS REQUIRED AND SHALL FURNISH CERTIFICATION OF INSPECTION TO OWNER AT THECOMPLETION OF PROJECT.F. ALL MATERIAL SHALL BE NEW AND UL APPROVED AND LABELED.G. UNLESS OTHERWISE NOTED, ALL INTERIOR CONDUIT SHALL BE IN MINIMUM 1/2" EMT WITH SET-SCREW FITTINGS. CONDUIT BELOW SLAB OR GRADE SHALL BEMINIMUM 3/4" RIGID CONDUIT OR PVC. CONDUIT WITHIN ELEVATED SLABS SHALL BE MINIMUM 1/2" EMT WITH COMPRESSION FITTINGS. EXTERIOR CONDUITABOVE GRADE SHALL BE MINIMUM 1/2" RIGID OR IMC. WHERE CONDUIT TRANSITIONS FROM BELOW SLAB OR GRADE TO ABOVE SLAB OR GRADE, PROVIDERIGID ELBOWS AND RIGID NIPPLES. FLEXIBLE METAL CONDUIT SHALL BE USED FOR CONNECTIONS TO LIGHT FIXTURES (NO LONGER THAN 6-FEET) OR FORCONNECTION TO VIBRATING EQUIPMENT SUCH AS MOTORS OR TRANSFORMERS (NO LONGER THAN 3-FEET). WHERE INSTALLED OUTSIDE OR IN AREASSUBJECT TO WATER, PROVIDE LIQUID-TIGHT FLEXIBLE METAL CONDUIT.H. UNLESS OTHERWISE NOTED, ALL CONDUCTORS SHALL BE TYPE THHN/THWN COPPER, SOLID FOR #10 OR SMALLER, STRANDED FOR #8 OR LARGER.CONDUCTORS #10 OR SMALLER SHALL HAVE COLORED INSULATION JACKET. MC CABLE MAY BE USED WHERE CONCEALED WITHIN WALLS AND ABOVECEILINGS. MINIMUM WIRE SIZE TO BE #12 AWG. ALL WIRE SHALL BE COPPER.I. LOW-VOLTAGE CABLE AND ASSOCIATED TIES SHALL BE PLENUM-RATED.J. TOGGLE SWITCHES TO BE SPECIFICATION GRADE, 20A, 120-277 VAC HUBBELL CATALOG #1221, #1222, #1223, 1224 (OR EQUIVALENT) WITH SMOOTH WHITEDEVICE PLATES UNLESS NOTED OTHERWISE. COORDINATE COLOR WITH ARCHITECT.K. DUPLEX RECEPTACLES TO BE SPECIFICATION GRADE, 20A, 120V HUBBELL CATALOG #5262 AND #GF5262 (OR EQUIVALENT) WITH SMOOTH WHITE DEVICEPLATES UNLESS NOTED OTHERWISE. COORDINATE COLOR WITH ARCHITECT.L. WALL BOX DIMMERS SHALL BE LUTRON NOVA T OR APPROVED EQUIVALENT. PROVIDE DIMMER TYPE TO MATCH THE TYPE OF LOAD BEING CONTROLLED.M. WALL BOX OCCUPANCY SENSORS SHALL BE WATTSTOPPER DW-100 DUAL TECHNOLOGY SENSORS OR APPROVED EQUIVALENT. SET TIMER TO 15-MINUTESUNLESS OTHERWISE NOTED.N. CEILING-MOUNTED OCCUPANCY SENSORS SHALL BE WATTSTOPPER DT-355-U (LINE VOLTAGE) DUAL TECHNOLOGY SENSORS. SET TIMER TO 15-MINUTESUNLESS OTHERWISE NOTED.O. ALL DEVICES INSTALLED IN AREAS EXPOSED TO THE WEATHER AND WHERE SPECIFICALLY INDICATED SHALL BE FURNISHED WITH A WEATHERPROOF DEVICEPLATE.P. LIGHTING FIXTURES AND LAMPS TO BE FURNISHED AND INSTALLED AS INDICATED ON THE LIGHTING FIXTURE SCHEDULE.Q. DISCONNECT SWITCHES SHALL BE HEAVY DUTY TYPE, NEMA 1 FOR INDOOR, NEMA 3R FOR OUTDOOR UNLESS INDICATED OTHERWISE.R. ALL ELECTRICAL EQUIPMENT AND SYSTEMS SHALL BE TESTED AND ADJUSTED FOR PROPER OPERATION. COMPLETED WIRING SYSTEM SHALL BE FREE OFSHORT CIRCUITS.S. TERMINATIONS (LUGS, TERMINAL BLOCKS, ETC.) IN CIRCUIT BREAKERS, DISCONNECT SWITCHES, LIGHTING CONTACTOR, RELAYS, PANELBOARDS, TIMESWITCHES, ETC. SHALL BE RATED FOR 75 DEGREES C IN TEMPERATURE. IF TERMINATIONS IN EQUIPMENT SUCH AS EXHAUST FANS, WATER HEATERS, AIRCONDITIONING UNITS, ETC., ARE RATED FOR 60 C ONLY, THEN CONDUCTORS MUST BE DE-RATED AND USED IN COMPLIANCE WITH TABLE 310-16 OF CURRENTNEC AND SIZED PER THE 60 DEGREES C COLUMN.A. DESIGN DRAWINGS ARE SCHEMATIC. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELDCONDITIONS. THE CONTRACT SHALL INCLUDE ALL LABOR AND MATERIAL NECESSARY FOR FIELD MODIFICATIONS WITH EXISTING CONDITIONS.B. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATION OF THE DESIGN.THE BID SHALL INCLUDE ALL ASSOCIATED COSTS TO MEET THE DESIGN INTENT. CLARIFICATION MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTERBIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT THE CONTRACTORS COST.C. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES. BID SHALL INCLUDE THE COSTS FOR ALL WORKINSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERTARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT.D. ELECTRICAL CONTRACTOR SHALL VERIFY EXACT OVER-CURRENT PROTECTION DEVICE/DISCONNECT REQUIREMENTS (PER NEC 440) WITH EQUIPMENTPROVIDED ON SITE & MANUFACTURER REQUIREMENTS. CONTACT ENGINEER WITH ANY DISCREPANCIES.E. COORDINATE ALL EQUIPMENT REQUIREMENTS WITH MANUFACTURER SPECIFICATIONS PRIOR TO ROUGH-IN FOR ALL NEW EQUIPMENT. CONTACT ENGINEERWITH ANY DISCREPANCIES.F. COORDINATE EXACT REQUIREMENTS FOR EXISTING EQUIPMENT TO REMAIN/BE RELOCATED IN THE FIELD. REFEED DEVICE FROM SAMEPANELBOARD/CIRCUIT BREAKER AS REQUIRED. SPLICE AND EXTEND ANY EXISTING CONDUIT AND WIRES TO NEW LOCATION AS REQUIRED. CONDUIT ANDWIRING SIZE SHALL MATCH EXISTING.G. CONTRACTOR SHALL VERIFY EXISTING DEMAND LOADS ON EXISTING PANELS AND FEEDERS. VERIFY ANY ADDITIONAL LOADS WILL NOT OVERLOAD THEASSOCIATED PANELBOARD OR CONDUCTORS.EXIT SIGN, TYPE AS DESIGNATED ON PLAN. PROVIDE NUMBER OF FACES AND CHEVRONS AS INDICATED ON PLAN. REFER TOLUMINAIRE SCHEDULE.OCCUPANCY SENSOR SWITCH. PROVIDE OVERLOADS SIZED FOR ITS ASSOCIATED MOTOR.LIGHT SWITCH, "2" INDICATES 2-POLE, "3" INDICATES 3-WAY, "4" INDICATES 4-WAY, "M" INDICATES MOTOR.SSOCHOMERUN TO PANELBOARD, LETTER INDICATES PANEL DESIGNATION. NUMBER INDICATES CIRCUIT NUMBER, SLASH MARKS INDICATE NUMBEROF CONDUCTORS IN SIZE CONDUIT AS REQUIRED BY NEC. NO SLASH MARKS INDICATES 2#12 & 1#12G - 1/2"C.CONDUIT CONCEALED ABOVE CEILINGS OR WITHIN WALLS .CONDUIT CONCEALED WITHIN SLAB OR BELOW GRADE.PANELBOARD 480Y/277V OR 208Y/120V, 3 PHASE, 4 WIRE UNLESS NOTED. SEE PANEL SCHEDULES FOR REQUIREMENTS.2X4 LUMINAIRE, TYPE AS DESIGNATED ON PLAN. REFER TO LUMINAIRE SCHEDULE. HALF SHADE DESIGNATES EMERGENCYFIXTURE.WALL MOUNTED LUMINAIRE, TYPE INDICATED. REFER TO LUMINAIRE SCHEDULE.RECESSED CAN LUMINAIRE, TYPE INDICATED. REFER TO LUMINAIRE SCHEDULE. HALF SHADE DESIGNATES EMERGENCY FIXTURE.NEMA 5-20R GROUNDING DUPLEX RECEPTACLE. MOUNT AT 18" ABOVE FINISHED FLOOR. RECEPTACLE AND COVERPLATE COLOR PERSPECIFICATIONS.NEMA 5-20R GROUNDING DUPLEX RECEPTACLE. MOUNT AT 42" ABOVE FINISHED FLOOR OR 6" ABOVE COUNTERTOP. RECEPTACLE ANDCOVERPLATE COLOR PER SPECIFICATIONS.NEMA 5-20R GROUNDING DUPLEX RECEPTACLE WITH 5 mA INTEGRAL GROUND FAULT SENSING DEVICE. MOUNT AT 18" ABOVE FINISHED FLOOR.(2) NEMA 5-20R GROUND DUPLEX RECEPTACLES WITHIN A SINGLE 2-GANG COVER PLATE. MOUNT AT 18" ABOVE FINISHED FLOOR.RECEPTACLES AND COVERPLATE COLORS PER SPECIFICATIONS.SPECIAL RECEPTACLE, NEMA 6-30R UNLESS NOTED OTHERWISE. MOUNT AS REQUIRED FOR APPLIANCE. RECEPTACLE ANDCOVERPLATE COLOR PER SPECIFICATIONS.TELEPHONE OUTLET. PROVIDE JUNCTION BOX AT 18" AFF. PROVIDE 3/4" CONDUIT FROM TELEPHONE BACKBAORD TO LOCATION SHOWN WITHFACEPLATE.ELECTRICAL LEGENDMOTOR CONNECTION. NUMBER INDICATES HORSEPOWER RATING.HEIGHTFIRE ALARM CONTROL PANELABBREVIATIONSJUNCTION BOXTHOUSAND CIRCULAR MILSKILOVOLT-AMPERESLIGHT EMITTING DIODEMAIN CIRCUIT BREAKERMINIMUMGALVANIZED RIGID CONDUITHIGH INTENSITY DISCHARGEKILO-AMPERESFIRE ALARMGROUNDMOUNTINGMAIN LUG ONLYGRCABOVE FINISHED FLOORAFFAFGAICDIAAWGCUCKTBKRATEXPELECAMPERE INTERRUPTING CAPACITYCIRCUITDIAMETEREXPLOSION-PROOFELECTRIC, ELECTRICALCOPPERABOVE FINISHED GRADEBREAKERAMERICAN WIRE GAUGECONDUIT, CONDUCTORAMPERE TRIPCLEDMINMCBMTGMLOHIDHTKAKVAKCMILJBAFACAMPERE FRAMEALTERNATING CURRENTAMPEREAFAFACPGNDPHASEPHRIGID GALVANIZED STEELUNLESS NOTED OTHERWISEPOLYVINYL CHLORIDEVOLTSVWATTS, WIREVOLT-AMPERESTRANSFORMERWVAAND&XFMRPANELTYPICALUNDERGROUNDPVCPNLUNOTYPUGRGSNEUTRALPOLEPUSH-BUTTONNEUTPPBNEMA 5-20R GROUNDING DUPLEX RECEPTACLE WITH 5mA INTEGRAL GROUND FAULT SENSING DEVICE. PROVIDE TAYMAC STANDARD CLEARCOVER WHICH MAINTAINS WEATHERPROOF RATING WHILE PLUG IS INSERTED. MOUNT AT 18" ABOVE FINISHED FLOOR.2X2 LUMINAIRE, TYPE AS DESIGNATED ON PLAN. REFER TO LUMINAIRE SCHEDULE. HALF SHADE DESIGNATES EMERGENCYFIXTURE.FLOOR BOX WITH INTEGRAL POWER & DATA COMPARTMENTS. PROVIDE ALL REQUIRED ACCOUTREMENT. ROUTE 1" CONDUIT FROM DATA SECTIONTO ABOVE CEILING. COORDINATE CONDUIT SIZE AND CABLING REQUIREMENTS WITH CABLING PLANT DRAWINGS AND INSTALLATION DESIGNPLANS. RAISED FLOOR FIRE RATED B.O.D. LEGRAND #AC8850, FIRE RATED BOX B.O.D. IS LEGRAND #EVOLUTION SERIES, CONCRETE POUR RATEDB.O.D. WIREMOLD RFB4. SUBSCRIPT INDICATES QUANTITY OF DATA JACKS AND CABLING.FUSED DISCONNECT SWITCH (NEMA 1 ENCLOSURE UNLESS OTHERWISE NOTED) DESIGNATED AS FOLLOWS:A=SWITCH SIZE, B=FUSE SIZE, C=POLES, D=NEMA TYPE.A/B/C/DFLIGHTSLTSRECEPTACLERECNEMA 5-20R GROUNDING DUPLEX RECEPTACLE WITH 5 mA INTEGRAL GROUND FAULT SENSING DEVICE. MOUNT AT 42" ABOVE FINISHED FLOOR OR6" ABOVE COUNTERTOP UNLESS NOTED OTHERWISE. REFER TO FOOD SERVICE DRAWINGS FOR RECEPTACLE MOUNTING HEIGHTS SERVING FOODEQUIPMENT.1/4FLOOR MOUNTED JUNCTION BOX AS INDICATED ON PLAN. SIZED AS REQUIRED FOR CONDUITS AND FILL.JD DEDICATED POWERE ESSENTIAL POWERUPS POWEREDUCEILING/PENDANT MOUNTED DUAL TECH, OCCUPANCY SENSOR.OCTELEPHONE/DATA OUTLET. PROVIDE JUNCTION BOX AT 18" AFF. PROVIDE 3/4" CONDUIT FROM TELEPHONE BACKBAORD TO LOCATION SHOWNWITH FACEPLATE. SUBSCRIPT INDICATES QUANTITY OF DATA JACKS AND CABLING.(2) NEMA 5-20R GROUNDING DUPLEX RECEPTACLE WITH 5 mA INTEGRAL GROUND FAULT SENSING DEVICE. MOUNT AT 42" ABOVE FINISHED FLOOROR 6" ABOVE COUNTERTOP.FIRE ALARM ANNUNCIATOR PANELFAAPGENERATOR ANNUNCIATOR PANELGAPFR/FFSFACPFAASSTSLIGHT FIXTURE SCHEDULETYPEMANUFACTURERDESCRIPTIONCATALOG NUMBERLAMPS & WATTAGEVOLTAGEREMARKSMOUNTINGGGE4" RECESSED DOWNLIGHT, 2500-LUMENSRECESSEDLITHONIA LIGHTING4" RECESSED DOWNLIGHT, 2500-LUMENS WITHEMERGENCY BATTERY PACKRECESSED120V120VPROVIDE WITH 0-10V DIMMING.PROVIDE WITH 0-10V DIMMING. PROVIDEWITH EMERGENCY BATTERY PACK WITHINTEGRAL TEST SWITCH.26W LED, 2700K26W LED, 2700KLDN4-27/25 L04 MVOLT GZ10LITHONIA LIGHTING LDN4-27/25 L04 MVOLT GZ10 EL120VAAE2X2 LED RECESSED ARCHITECTURAL TROFFER,SINGLE LENS, 4000-LUMENS2X2 LED RECESSED ARCHITECTURAL TROFFER,SINGLE LENS, 4000-LUMENS WITH EMERGENCYBATTERY PACKRECESSEDRECESSED2GTL 2 40L GZ10 LP83533W LED, 3500K33W LED, 3500KPROVIDE WITH 0-10V DIMMING.PROVIDE WITH 0-10V DIMMING. PROVIDEWITH EMERGENCY BATTERY PACK.120VLITHONIA LIGHTING2GTL 2 40L GZ10 LP835 EL14L120VBBE2X4 LED RECESSED ARCHITECTURAL TROFFER,SINGLE LENS, 7200-LUMENS2X4 LED RECESSED ARCHITECTURAL TROFFER,SINGLE LENS, 7200-LUMENS WITH EMERGENCYBATTERY PACKRECESSEDRECESSED2GTL 4 72L GZ10 LP83553W LED, 3500K53W LED, 3500KPROVIDE WITH 0-10V DIMMING.PROVIDE WITH 0-10V DIMMING. PROVIDEWITH EMERGENCY BATTERY PACK.120VLITHONIA LIGHTING2GTL 4 72L GZ10 LP835 EL14LLITHONIA LIGHTINGLITHONIA LIGHTINGHHE4" RECESSED DOWNLIGHT, 3000-LUMENSRECESSEDLITHONIA LIGHTING4" RECESSED DOWNLIGHT, 3000-LUMENS WITHEMERGENCY BATTERY PACKRECESSED120V120VPROVIDE WITH 0-10V DIMMING.PROVIDE WITH 0-10V DIMMING. PROVIDEWITH EMERGENCY BATTERY PACK WITHINTEGRAL TEST SWITCH.35W LED, 2700K35W LED, 2700KLDN4-27/30 L04 MVOLT GZ10LITHONIA LIGHTING LDN4-27/30 L04 MVOLT GZ10 ELG24" RECESSED WALL WASHER, 2500-LUMENSRECESSEDLITHONIA LIGHTING 120VPROVIDE WITH 0-10V DIMMING.26W LED, 2700KLDN4-27/25 LW4 MVOLT GZ10DF1DECORATIVE FIXTURE 1PENDANT-120V50W MAXTO BE SELECTED BY OTHERSDF2DECORATIVE FIXTURE 2PENDANT- 120V75W MAXTO BE SELECTED BY OTHERSDS1DECORATIVE WALL SCONCE 1WALL-120V25W MAXTO BE SELECTED BY OTHERSDS2DECORATIVE WALL SCONCE 2WALL- 120V25W MAXTO BE SELECTED BY OTHERSDF3DECORATIVE FIXTURE 3PENDANT- 120V100W MAXTO BE SELECTED BY OTHERSDF4DECORATIVE FIXTURE 4PENDANT- 120V50W MAXTO BE SELECTED BY OTHERSF4" SHOWER RATED DOWNLIGHTRECESSEDLITHONIA LIGHTING 120VPROVIDE WITH 0-10V DIMMING. PROVIDEWITH NON-CONDUCTIVE TRIM.26W LED, 2700KTO BE SELECTED BY OTHERSX1SLIM LINE, EDGE LIT EXIT SIGN WITH MIRRORFINISH AND GREEN LETTERINGLIGHTALARMSCOORDINATE MOUNTING STYLE ANDREQUIRED HARDWARE WITHARCHITECTURAL RCP.INCLUDED (LED)120VSURFACE/WALL/PENDANTSELECTED BY OTHERSKDECORATIVE VANITY SCONCEWALL120V26W LED, 2700KSELECTED BY OTHERSLITHONIA LIGHTINGX2LOW PROFILE EMERGENCY BUGEYE FIXTURE LIGHTALARMSCOORDINATE MOUNTING STYLE ANDREQUIRED HARDWARE WITHARCHITECTURAL RCP.INCLUDED (LED)120VSELECTED BY OTHERSWALLDIMMER SWITCH.SDDIMMER 3-WAY SWITCH.SD3DIMMER OCCUPANCY SWITCH.SDOREFER TO INTERIORS FOR SPECIFICATIONREFER TO INTERIORS FOR SPECIFICATIONREFER TO INTERIORS FOR SPECIFICATIONREFER TO INTERIORS FOR SPECIFICATIONREFER TO INTERIORS FOR SPECIFICATIONREFER TO INTERIORS FOR SPECIFICATIONSLED STRIP LIGHTSURFACE120V- 120V4.5W/FT MAX, 2700KTO BE SELECTED BY OTHERSREFER TO INTERIORS FOR SPECIFICATIONPROFESSIONALENGINEERNo. 85909WILLIAMS.GADDYJR.STATE OFLICENSEFLORIDADRAWN BY:PROJECT NO.:SCALE:REVISIONNO.DATEDESCRIPTIONTHE INFORMATION SHOWN ON THESE DRAWINGS IS OWNED BY AND IS THE PROPERTY OFSHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. NO PART THEREOF SHALL BE COPIED, ADAPTED, OR DISTRIBUTED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OFSHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS.COPYRIGHT © 202326560 AGOURA ROAD, SUITE 106CALABASAS, CA 91302310.670.9144A S S O C I A T E SARCHITECTS + ENGINEERSS H E P P H I R Dwill.s@shep-ae.com112-02-22SD PRICING22-10-23DD PRICING39-07-23PHASE 2 90% CDAtlantic Beach Country ClubPhase 2Construction Documents1600 Selva Marina DriveAtlantic Beach, FL 3223312" = 1'-0"1-E0.1ELECTRICAL COVER SHEET2022-352Author