ABCC P2 - Bldg 1 - 1-E0-2_1= FIRE ALARM SYSTEMFAS- FIRE ALARM SYSTEM- 120/208VREDBLACKUSE THE FOLLOWINGCOLOR CODE:- FAS- PANELBOARD & CIRCUIT #USE A BLACK MARKER INTHIS SPACE TO IDENTIFYTHE ONE THAT APPLIES:LA-1ENCASE RECEPTACLE JUNCTION BOX ON ALL SIDESWITH UL LISTED FIRE-RATED "PUTTY PACK". TYPICALFOR ALL BACK-TO-BACK RECEPTACLES IN FIRERATED WALLS THAT ARE LESS THAN 24" ON CENTER.LESS THAN24" APARTRECEPTACLECOVER PLATEJUNCTION BOXBOTH NEUTRAL AND PHASECONDUCTOR SHALL BEINSTALLED AS SHOWN. DONOT USE DEVICES AS FEEDTHROUGH TO OTHER DEVICESLUG ON BOX.TO GROUNDNOTE:NEUTRAL OR PHASE CONDUCTORRECEPTACLEL RATING AT AMBIENT - LESS THAN 1 CFM/SQ FTF RATINGS - 1 AND 2 HR (SEE ITEMS 1 AND 3)AASECTION A-A21BL RATING AT 400F - 4 CFM/SQ FTT RATING - 0 HR3SYSTEM NO. W-L-10541A1 WALL ASSEMBLY -- THE 1 OR 2 HR FIRE-RATED GYPSUM WALLBOARD/ STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OFTHE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL AND PARTITION DESIGNS INTHE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES:A. STUDS -- WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TOCONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC. STEEL STUDS TO BE MIN 2-1/2 IN. WIDE AND SPACED MAX24 IN. OC. WHEN STEEL STUDS ARE USED AND THE DIAM OF OPENING EXCEEDS THE WIDTH OF STUD CAVITY, THEOPENING SHALL BE FRAMED ON ALL SIDES USING LENGTHS OF STEEL STUD INSTALLED BETWEEN THE STUDCAVITY, THE OPENING SHALL BE FRAMED ON ALL SIDES USING LENGTHS OF STEEL STUD INSTALLED BETWEENTHE VERTICAL STUDS AND SCREW-ATTACHED TO THE STEEL STUDS AT EACH END. THE FRAMED OPENING IN THEWALL SHALL BE 4 TO 6 IN. WIDER AND 4 TO 6 IN. HIGHER THAN THE DIAM OF THE PENETRATING ITEM SUCH THAT,WHEN THE PENETRATING ITEM IS INSTALLED IN THE OPENING, A 2 TO 3 IN. CLEARANCE IS PRESENT BETWEEN THEPENETRATING ITEM AND THE FRAMING ON ALL FOUR SIDES.B. GYPSUM BOARD* -- 5/8 IN. THICK, 4 FT WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM BOARD TYPE,THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THEINDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM OF OPENING IS32-1/4 IN. FOR STEEL STUD WALLS. MAX DIAM OF OPENING IS 14-1/2 IN. FOR WOOD STUD WALLS.THE F RATING OFTHE FIRESTOP SYSTEM IS EQUAL TO THE FIRE RATING OF THE WALL ASSEMBLY.2 THROUGH-PENETRANTS -- ONE METALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED EITHER CONCENTRICALLY ORECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE SHALL BE MIN 0 IN. TO MAX 2-1/4 IN. PIPE MAY BEINSTALLED WITH CONTINUOUS POINT CONTACT. PIPE, CONDUIT OR TUBING MAY BE INSTALLED AT AN ANGLE NOT GREATERTHAN 45 DEGREES FROM PERPENDICULAR. PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALLASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED:A. STEEL PIPE -- NOM 30 IN DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE.B. IRON PIPE -- NOM 30 IN. DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE.C. CONDUIT -- NOM 4 IN DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING OR 6 IN. DIAM STEEL CONDUIT.D. COPPER TUBING -- NOM 6 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING.E. COPPER PIPE -- NOM 6 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE.3 FILL, VOID OR CAVITY MATERIAL* -- SEALANT -- MIN 5/8 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS,FLUSH WITH BOTH SURFACES OF WALL. AT THE POINT OR CONTINUOUS CONTACT LOCATIONS BETWEEN PIPE AND WALL, AMIN 1/2 IN. DIAM BEAD OF FILL MATERIAL SHALL BE APPLIED AT THE PIPE WALL INTERFACE ON BOTH SURFACES OF WALL.SCALE:JUNCTION BOXCOVER PLATE DETAILNOT TO SCALEBACK-TO-BACK RECEPTACLESIN FIRE RATED WALLTYPICAL MULTI-WIRE BRANCHCIRCUIT RECEPTACLE DETAILTYPICAL CONDUIT PENETRATIONTHROUGH FIRE-RATED WALL4231E0.10SCALE:NOT TO SCALESCALE:NOT TO SCALESCALE:NOT TO SCALEEXISTING ELECTRICAL RISER DIAGRAM - PHASE 25SCALE:NOT TO SCALE- CATV- CABLE TV SYSTEMGREEN- INTERCOM SYSTEMBLUE= CABLE TV SYSTEMCATVE0.10E0.10E0.10E0.10NEW ELECTRICAL RISER DIAGRAM - PHASE 26SCALE:NOT TO SCALEE0.10RTU-1TAGMECHANICAL EQUIPMENT CONNECTION SCHEDULEROOF TOP UNIT 1EQUIPMENT DESCRIPTION. .VOLTS/ HP∅KWMDP-14,16,18(154)CIRCUITFLA/3#2/0 & 1#6G IN 1-1/2"CCONDUCTORSDISC. SWITCHFrame/Fuse/Poles/Encl.CONDUIT AND(MCA)PROVIDED WITH EQUIPMENT208/3DOAU-1 OUTDOOR AIR UNIT 1 . . (174) PROVIDED WITH EQUIPMENT208/3FCU-1 FAN COIL UNIT 1 . . N-19,21(1.8) 2#12 & 1#12G IN 1/2"C208/1FCU-2 FAN COIL UNIT 2 . . N-23,25(1.8)208/1FCU-3 FAN COIL UNIT 3 . . N-27,29(1.8)208/1FCU-4 FAN COIL UNIT 4 . . N-31,33(1.4)208/1FCU-5 FAN COIL UNIT 5 . . N-35,37(1.4)208/1 . .FCU-6 FAN COIL UNIT 6 . . N-39,41(0.8)208/1 . .. .VRF-1 HEAT RECOVERY UNIT 1 . . N-32,34,36(27.3) PROVIDED WITH EQUIPMENT208/3BS-1 VRF BRANCH SELECTOR 1 . . (0.6) PROVIDED WITH EQUIPMENT208/1 . .. .. .KSF-1 HOOD SUPPLY FAN 1 . . MDP-26,28,30(10.2) PROVIDED WITH EQUIPMENT208/3 . .. .. .. .KSF-2 HOOD SUPPLY FAN 2 . . MDP-32,34,36(10.2) PROVIDED WITH EQUIPMENT208/3KEF-1 HOOD EXHAUST FAN 1 . . MDP-38,40(16) PROVIDED WITH EQUIPMENT208/1 . .. .. .. .KEF-2 HOOD EXHAUST FAN 2. .MDP-42,44,46(10) PROVIDED WITH EQUIPMENT208/3. .. .. .. .EF-1 EXHAUST FAN 1 . . REUSE EXSITING(4.1) PROVIDED WITH EQUIPMENT120/1 . .. .. .. .. .. .. .. .. .EF-2 EXHAUST FAN 2 . . REUSE EXISTING(4.1) PROVIDED WITH EQUIPMENT120/1 . .. .. .. .. .. .. .. .. .EF-3A EXHAUST FAN 3A . . REUSE EXISTING(1.9) PROVIDED WITH EQUIPMENT120/1 . .. .. .. .. .. .. .. .. .EF-3B EXHAUST FAN 3B . . REUSE EXISTING(1.9) PROVIDED WITH EQUIPMENT120/1 . .. .. .. .. .. .. .. .. .EF-5A EXHAUST FAN 5A . . REUSE EXISTING(1.9) PROVIDED WITH EQUIPMENT120/1 . .. .. .. .. .. .. .. .. .EF-5B EXHAUST FAN 5B . . REUSE EXISTING(1.9) PROVIDED WITH EQUIPMENT120/1 . .. .. .. .. .. .. .. .. .EF-8 EXHAUST FAN 8 . . D-25(1.4) PROVIDED WITH EQUIPMENT120/1 . .. .. .. .. .. .. .. .. .EF-9 EXHAUST FAN 9 . . D-25(1.4) PROVIDED WITH EQUIPMENT120/1 . .. .. .. .RH 1-1 GAS RADIANT HEATER 1-1 . . B-311.0 PROVIDED WITH EQUIPMENT120/1 . .. .. .. .RH 1-2 GAS RADIANT HEATER 1-2 . . 1.0 PROVIDED WITH EQUIPMENT120/1 . .. .. .. .RH 1-3 GAS RADIANT HEATER 1-3 . . 1.0 PROVIDED WITH EQUIPMENT120/1 . .. .. .. .RH 1-4 GAS RADIANT HEATER 1-4 . . 1.0 PROVIDED WITH EQUIPMENT120/1 . .. .. .. .RH 1-5 GAS RADIANT HEATER 1-5 . . 1.0 PROVIDED WITH EQUIPMENT120/1 . .. .. .. .RH 1-6 GAS RADIANT HEATER 1-6 . . 1.0 PROVIDED WITH EQUIPMENT120/1 . .. .. .. .3#2/0 & 1#6G IN 1-1/2"C2#12 & 1#12G IN 1/2"C2#12 & 1#12G IN 1/2"C2#12 & 1#12G IN 1/2"C2#12 & 1#12G IN 1/2"C2#12 & 1#12G IN 1/2"C3#10 & 1#10G IN 3/4"C2#12 & 1#12G IN 1/2"C4#12 & 1#12G IN 1/2"C4#12 & 1#12G IN 1/2"C2#12 & 1#12G IN 1/2"C3#12 & 1#12G IN 1/2"C2#12 & 1#12G IN 1/2"C2#12 & 1#12G IN 1/2"C2#10 & 1#10G IN 1/2"CN-38,40,42N-28,30KEF-4 DISHWASHER EXHAUST FAN 4 EM-60(11) PROVIDED WITH EQUIPMENT120/1. .. .. .. .. .RH 1-7 GAS RADIANT HEATER 1-7 . . 1.0 PROVIDED WITH EQUIPMENT120/1 . .. .. .. .RH 1-8 GAS RADIANT HEATER 1-8 . . 1.0 PROVIDED WITH EQUIPMENT120/1 . .. .. .. .2#10 & 1#10G IN 1/2"C2#10 & 1#10G IN 1/2"C2#10 & 1#10G IN 1/2"C2#10 & 1#10G IN 1/2"C2#10 & 1#10G IN 1/2"C2#10 & 1#10G IN 1/2"C2#10 & 1#10G IN 1/2"CB-31B-31B-31B-31B-31B-31B-31PROVIDED WITH EQUIPMENTPROVIDED WITH EQUIPMENTPROVIDED WITH EQUIPMENTPROVIDED WITH EQUIPMENTPROVIDED WITH EQUIPMENTPROVIDED WITH EQUIPMENT. .. .. .. .. .EF-10 EXHAUST FAN 10 . . D-25(1.4) PROVIDED WITH EQUIPMENT120/1 . .. .. .. .2#12 & 1#12G IN 1/2"CREUSE EXISTINGREUSE EXISTINGREUSE EXISTINGREUSE EXISTINGREUSE EXISTINGREUSE EXISTING2#12 & 1#12G IN 1/2"CONE-LINE GENERAL NOTES(THIS DRAWING ONLY)ONE-LINE KEYED NOTES(THIS DRAWING ONLY)CONDUCTOR SCHEDULE(THIS DRAWING ONLY)EXISTING MDP SERVICE LOAD SUMMARYA. WHERE NEW CIRCUITS BREAKERS ARE PROVIDED IN EXISTING PANELBOARDS, NEW BREAKERSARE TO MATCH EXISTING MANUFACTURER AND AIC RATING.B. CONTRACTOR TO FIELD VERIFY NEW EQUIPMENT LOADS WILL NOT OVERLOAD ELECTRICALPANELBOARDS OR SERVICE. NOTIFY THE ENGINEER OF RECORD IMMEDIATELY WITH ANYCONCERNS.C. REFER TO ELECTRICAL SITE PLAN FOR ADDITIONAL INFORMATION.REFER TO PANEL SCHEDULES FOR NEW BRANCH CIRCUIT BREAKER REQUIREMENTS.PROVIDE NEW 150A, 120/208V, 3-PHASE, 4-WIRE RECESSED PANELBOARD IN NEMA 1ENCLOSURE.NEW ELECTRICAL SERVICE AND PANELBOARD. BOND NEUTRAL AND GROUND TOGETHER.PROVIDE #3/0 BARE COPPER CABLE BONDED TO THE FOLLOWING: BUILDING WATER LINE, 40' OF1/2" REBAR WITHIN EXTERIOR FOUNDATION FOOTER, TWO GROUND RODS SPACED 10'-0" APART,AND BUILDING STEEL.PROVIDE 100% RATED MAIN CIRCUIT BREAKER FOR PANELBOARD.COORDINATE NEW TRANSFORMER AVAILABILITY WITH THE UTILITY COMPANY AS EARLY ASPOSSIBLE. NOTIFY THE ENGINEER OF RECORD IMMEDIATELY WITH ANY CONFLICTS ORCONCERNS.AIC CALCULATIONS PERFORMED WERE BASED ON A 150KVA TRANSFORMER WITH 1.8%IMPEDANCE. SHOULD ACTUAL TRANSFORMER INSTALLED BE LARGER, HAVE A LOWER PERCENTIMPEDANCE, OR BE LOCATED CLOSER TO THE SERVICE DISCONNECT, THE PANELBOARD AICRATING SHALL BE ADJUST ACCORDINGLY.DISCONNECT EXISTING CIRCUIT MDP-31,33,35 AND ASSOCIATED 175A CIRCUIT BREAKERSERVING FITNESS CENTER AIR HANDLING UNIT (AHU-8). AIR HANDLING UNIT TO BE FED FROMNEW PANELBOARD 'N'. RELOCATE CIRCUIT AND BREAKER TO CIRCUIT N-1,3,5. REFER TO PANELSCHEDULES AND NEW WORK POWER PLAN FOR ADDITIONAL INFORMATION.TRANSFORMERCOMPANYUTILITY1ST FLOORROOFEXISTINGPANELMDP1200A MCB208Y/120V3 , 4WPANELEM200A MLO208Y/120V3 , 4WPANELAC225A MLO208Y/120V3 , 4WPANELEMA60A MLO208Y/120V3 , 4WMEZZANINEPANELK200A MLO208Y/120V3 , 4WPANELL200A MLO208Y/120V3 , 4WPANELM400A MLO208Y/120V3 , 4WCLUBHOUSECLUBHOUSECLUBHOUSESECURITY 203MECHANICAL 204234156TO OTHER ELECTRICAL SERVICETO OTHER ELECTRICAL SERVICETO OTHER ELECTRICAL SERVICEPANELB150A208Y/120V3 , 4WPANELN400A MCB208Y/120V3 , 4W1ST FLOORTRANSFORMERCOMPANYUTILITYNEWTAG CONDUIT AND CONDUCTORS4#500KCMIL & 1#3G IN 3-1/2"C121(EXISTING) (EXISTING)(EXISTING) (EXISTING) (EXISTING) (EXISTING)(EXISTING)11(NEW)CLUBHOUSE2(NEW)3 454#1/0 & 1#6G IN 2"C21 7PANELD150A208Y/120V3 , 4W(NEW)2212-MONTH PEAK DEMAND (EXISTING): 139.6kW x 125% (NEC 220.87) = 174.5 kW EXISTING DEMANDDEMOLISHED EQUIPMENT: 54.1kWNEW EQUIPMENT LOAD (DIVERSIFIED): 186.1kWNEW TOTAL LOAD (DIVERSIFIED): 174.5kW - 54.1kW + 186.1kW = 306.5kW / 360 = 851A17640,064A16,032A7,852A 17,429ALC-1 LC-2TIME CLOCKPROFESSIONALENGINEERNo. 85909WILLIAMS.GADDYJR.STATE OFLICENSEFLORIDADRAWN BY:PROJECT NO.:SCALE:REVISIONNO.DATEDESCRIPTIONTHE INFORMATION SHOWN ON THESE DRAWINGS IS OWNED BY AND IS THE PROPERTY OFSHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. NO PART THEREOF SHALL BE COPIED, ADAPTED, OR DISTRIBUTED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OFSHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS.COPYRIGHT © 202326560 AGOURA ROAD, SUITE 106CALABASAS, CA 91302310.670.9144A S S O C I A T E SARCHITECTS + ENGINEERSS H E P P H I R Dwill.s@shep-ae.com112-02-22SD PRICING22-10-23DD PRICING39-07-23PHASE 2 90% CDAtlantic Beach Country ClubPhase 2Construction Documents1600 Selva Marina DriveAtlantic Beach, FL 322331-E0.2ELECTRICAL DETAILS & ONE-LINE2022-352Author