Loading...
ABCC P2 - Bldg 1 - 1-E2-1_1DryerWasherTVTSFSTVJJJJFFFJTVJJOFFICE, TBD132BCATERING DIR. / TBD132CDRY STORAGE 1132ASTORAGE132DSTORAGE132EBREAK ROOM133RR134RR135BEER / WINE COOLER131MOUTSIDE SERVICE SNACKBAR131KBAR PANTRY131LCHEF & SOUSE CHEF131ALAUNDRY137AQUATICS STAFF138FOYER100GOLF PRO SHOP122MEN'S LOCKERS123VESTIBULE113ESERVICE BAR116WOMEN'S RESTROOM117WOMEN'S LOCKERS110WOMEN'S PRIVATERESTROOM106WOMEN'S RESTROOM108WOMEN'S SHOWERS107MEMBERSHIP OFFICE104HALL103VESTIBULE105RECEPTION101VESTIBULE102DINING VESTIBULE118VESTIBULE119MULTI-PURPOSE ROOM126DINING LOGGIA124KITCHEN131COOLER131FBEER COOLER131DFREEZER131EDRY STORAGE131CBAKE SHOP131BWASH STATION131JTABLE STORAGE129HALL128WAITING AREA101BRECEPTION DESK101AFDC / RISER109DRESSING107CMEN'S POOL RESTROOM142WOMEN'S POOLRESTROOM145VESTIBULE141VESTIBULE144ACCESSIBLE RESTROOM145EACCESSIBLE RESTROOM142DBREEZEWAY010ABULK COOLER132GCORRIDOR132VESTIBULE114MEN'S PRIVATE RESTROOM113DINING HALL125CORRIDOR131NMEN'S RESTROOM115PRIVATE VESTIBULE111SHOE SHINE AREA112GOLF PORCH008BREEZEWAY010AEMKMDPLNREFUSE & RECYCLING113GBULK FREEZER132 FPRH1-1RH1-2RH1-3RH1-4RH1-5RH1-6FCU1BS1FCU2FCU3FCU41-E5.111-E5.12BEF5AEF5BEF8EF9EF1EF3BEF3AEF212346D5D-1D-3D-5D-7,9D-11D-15,17D-19D-13D-21D-23D-2D-4D-6D-8POOL BAR0097B-989101011GAS WATERHEATER WH-112GAS WATERHEATER WH-313D-261415B-24B-26B-281616PROFESSIONALENGINEERNo. 85909WILLIAMS.GADDYJR.STATE OFLICENSEFLORIDADRAWN BY:PROJECT NO.:SCALE:REVISIONNO.DATEDESCRIPTIONTHE INFORMATION SHOWN ON THESE DRAWINGS IS OWNED BY AND IS THE PROPERTY OFSHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. NO PART THEREOF SHALL BE COPIED, ADAPTED, OR DISTRIBUTED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OFSHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS.COPYRIGHT © 202326560 AGOURA ROAD, SUITE 106CALABASAS, CA 91302310.670.9144A S S O C I A T E SARCHITECTS + ENGINEERSS H E P P H I R Dwill.s@shep-ae.com112-02-22SD PRICING22-10-23DD PRICING39-07-23PHASE 2 90% CDAtlantic Beach Country ClubPhase 2Construction Documents1600 Selva Marina DriveAtlantic Beach, FL 322331/8" = 1'-0"1-E2.1PHASE 2 -MAIN CLUBHOUSE POWER PLAN -LEVEL 12022-352AJS1/8" = 1'-0"1-E2.12MAIN CLUBHOUSE POWER PLAN - LEVEL 1 - PHASE 2SHEET KEYNOTES:X1. NEW LOCATION FOR EXISTING WASHER AND DRYER RECEPTACLES. WASHER AND DRYER FED FROM PANEL P LOCATED IN BREEZEWAY CLOSET. SPLICE AND EXTEND ASSOCIATED CONDUIT AND CONDUCTORS TO NEW LOCATION AS NEEDED.2. NEW LOCATION FOR EXISTING TAMPER AND FLOW SWITCHES. SPLICE AND EXTEND CIRCUITING TO NEW LOCATION AS NEEDED. COORDINATE EXACT LOCATION WITH FIRE SUPRESSION CONTRACTOR PRIOR TO WORK.3. NEW LOCATION FOR ELECTRICAL CHASE CLOSET. SPLICE AND EXTEND ALL CIRCUITING TO NEW LOCATION AS NEEDED.4. NEW 150A, MLO, 208/120V, 3-PH, 4-WIRE PANELBOARD 'B' IN NEMA 1 ENCLOSURE. REFER TO ELECTRICAL ONE-LINE AND PANEL SCHEDULE FOR ADDITIONAL INFORMATION.5. NEW 150A, MLO, 208/120V, 3-PH, 4-WIRE PANELBOARD 'D' IN NEMA 1 ENCLOSURE. REFER TO ELECTRICAL ONE-LINE AND PANEL SCHEDULE FOR ADDITIONAL INFORMATION.6. NEW 400A, MCB, 208/120V, 3-PH, 4-WIRE PANELBOARD 'N' IN NEMA 1 ENCLOSURE. REFER TO ELECTRICAL ONE-LINE FOR FEEDER INFORMATION.7. DISCONNECT EXISTING CIRCUIT MDP-31,33,35 AND ASSOCIATED 175A CIRCUIT BREAKER SERVING FITNESS CENTER AIR HANDLING UNIT #8 (AHU-8). AHU-8 TO BE FED FROM NEW PANELBOARD 'N'. INTERCEPT, SPLICE AND EXTEND EXISTING CONDUIT AND CONDUCTORS SERVING AHU-8 TO PANELBOARD 'N'. RELOCATE TO CIRCUIT N-1,3,5. REFER TO ELECTRICAL ONE-LINE AND PANELBOARD SCHEDULES FOR ADDITIONAL INFORMATION.8. CONTRACTOR TO PROVIDE (4) DOWNLIGHTS WITHIN CABINET MILLWORK. REFER TO LIGHTING PLAN AND INTERIORS PACKAGE FOR ADDITIONAL INFORMATION.9. CLOCK RECEPTACLE. MOUNT AT 5'-0" AFF. COORDINATE EXACT LOCATION PRIOR TO ROUGH-IN.10. RECEPTACLE TO SERVE WINE DISPLAY CABINET. MOUNT RECEPTACLE AT 72" AFF. COORDINATE LOCATION WITH MILLWORK PROVIDER PRIOR TO WORK.11. PROVIDE NEW SINGLE COMPARTMENT FLOOR BOX WITH DUPLEX OUTLET AND BRONZE COVER. TRENCH TO NEAREST WALL AND CONNECT TO EXISTING RECEPTACLE CIRCUIT. COORDINATE CUT AND PATCH REQUIREMENTS PRIOR TO WORK.12. RECEPTACLE TO SERVE FOR GAS WATER HEATER CONTROLS. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH PLUMBING DRAWINGS AND PLUMBING CONTRACTOR PRIOR TO WORK. CONNECT RECEPTACLE TO ADJACENT EXTERIOR RECEPTACLE CIRCUIT SERVING EXISTING MECHANICAL EQUIPMENT.13. RECEPTACLE TO SERVE FOR GAS WATER HEATER CONTROLS. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH PLUMBING DRAWINGS AND PLUMBING CONTRACTOR PRIOR TO WORK.14. ELECTRICAL WATER COOLER. PROVIDE CONNECTION AS REQUIRED FOR DRINKING FOUNTAIN PROVIDED. COORDINATE EXACT REQUIREMENTS PRIOR TO ROUGH-IN.15. PROVIDE TV PROVISIONS ABOVE CEILING FOR FUTURE ACCESS/USE. 16. PROVIDE 2#12, 1#12 GND IN 1/2"C FOR 120V HARDWIRED CONNECTION TO ELECTRIC FIREPLACE.A. CONDUIT SHOWN OUTSIDE OF THE BUILDING FOR CLARITY ONLY. ALL CONDUITS SHALL REMAIN WITHIN THE WALL OR BUILDING.B. BRANCH CIRCUITS SHALL HAVE THE SAME SIZE CONDUCTORS FOR THE ENTIRE LENGTH OF THE CIRCUIT.C. ALL ELECTRICAL EQUIPMENT, DEVICES AND ASSOCIATED CIRCUITING NOT SHOWN ON THIS PLAN ARE EXISTING TO REMAIN.D. REWORK CIRCUITS AS NEEDED TO MAINTAIN CONTINUITY OF EXISTING DEVICES TO REMAIN.E. COORDINATE CORD & PLUG REQUIREMENTS WITH PURCHASED EQUIPMENT PRIOR TO WORK.F. COORDINATE FINAL LOCATION AND MOUNTING HEIGHTS OF TELEVISIONS, EQUIPMENT, RECEPTACLES WITH INTERIOR ELEVATIONS AND MILLWORK PROVIDER PRIOR TO WORK.G. COORDINATE WITH THE MECHANICAL DRAWINGS AND THE MECHANICAL CONTRACTOR FOR THE EXACT LOCATION AND REQUIREMENTS OF ALL MECHANICAL EQUIPMENT PRIOR TO WORK.H. REFER TO MECHANICAL EQUIPMENT CONNECTION SCHEDULE ON SHEET 1-E0.2 FOR ELECTRICAL REQUIREMENTS. I. EXISTING BREAKERS SERVING CIRCUITS COMPLETELY DEMOLISHED MAY BE REUSED TO SERVE NEW CIRCUITS.J. WHERE CIRCUITS ARE COMPLETELY DEMOLISHED AND NOT REUSED, LABEL CIRCUITS AS 'SPARE' IN THEIR PANELBOARD DIRECTORY.K. FIRE ALARM DEVICES SHOWN ON THIS PLAN ARE NEW. PROVIDE COMPATIBLE DEVICES AND CONNECT INTO EXISTING FIRE ALARM SYSTEM.GENERAL NOTES