Loading...
ABCC P2 - Bldg 1 - 1-E5-1_1TV TVJdJJJDJJJJJFFdD3D3ODTVTVTV SERVICE BAR116B33322441B-1B-3B-5B-7B-11B-13(TIE)B-13(TIE)B-13(TIE)B-15B-17,19B-21B-23B-2B-4B-6B-8B-10B-12B-18B-14,16B-20B-22B-25B-275B-29(TIE)B-29(TIE)BAR1206CORRIDOR131NBAR PANTRY131LOUTSIDE SERVICE SNACKBAR131KCHEF & SOUSE CHEF131ABEER / WINE COOLER131MEM-1EM-3EM-5EM-51EM-7EM-9(TIE)EM-9(TIE)EM-11EM-13EM-15,17EM-19EM-21EM-23EM-25,27,29EM-31EM-33EM-35EM-2EM-4,6EM-8(TIE)EM-28(TIE)EM-28(TIE)EM-8(TIE)EM-24EM-10EM-18EM-20EM-221EM-26EM-30,32EM-34EM-36EM-44EM-46RH1-7RH1-8EM-53(TIE)EM-53(TIE)POOL BAR009+96"+96"7EM-48PROFESSIONALENGINEERNo. 85909WILLIAMS.GADDYJR.STATE OFLICENSEFLORIDADRAWN BY:PROJECT NO.:SCALE:REVISIONNO.DATEDESCRIPTIONTHE INFORMATION SHOWN ON THESE DRAWINGS IS OWNED BY AND IS THE PROPERTY OFSHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. NO PART THEREOF SHALL BE COPIED, ADAPTED, OR DISTRIBUTED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OFSHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS.COPYRIGHT © 202326560 AGOURA ROAD, SUITE 106CALABASAS, CA 91302310.670.9144A S S O C I A T E SARCHITECTS + ENGINEERSS H E P P H I R Dwill.s@shep-ae.com112-02-22SD PRICING22-10-23DD PRICING39-07-23PHASE 2 90% CDAtlantic Beach Country ClubPhase 2Construction Documents1600 Selva Marina DriveAtlantic Beach, FL 322331/4" = 1'-0"1-E5.1ENLARGED BAR PLANS2022-352AJSFloor Plan1-E5.11MAIN CLUBHOUSE BAR POWER PLAN - LEVEL 1 - PHASE 2Floor Plan1-E5.12MAIN CLUBHOUSE POOL BAR POWER PLAN - LEVEL 1 - PHASE 2A. REFER TO FOOD SERVICE DRAWINGS FOR ADDITIONAL INFORMATION INCLUDING EQUIPMENT, EQUIPMENT REQUIREMENTS, DEVICE MOUNTING HEIGHTS AND INSTALLATION INSTRUCTIONS.B. CONDUIT SHOWN OUTSIDE OF THE BUILDING FOR CLARITY ONLY. ALL CONDUITS SHALL REMAIN WITHIN THE WALL OR BUILDING.C. BRANCH CIRCUITS SHALL HAVE THE SAME SIZE CONDUCTORS FOR THE ENTIRE LENGTH OF THE CIRCUIT.D. COORDINATE CORD & PLUG REQUIREMENTS WITH PURCHASED EQUIPMENT PRIOR TO WORK.E. COORDINATE FINAL LOCATION AND MOUNTING HEIGHTS OF EQUIPMENT AND DEVICES WITH INTERIOR ELEVATIONS AND MILLWORK PROVIDER PRIOR TO WORK.F. COORDINATE WITH THE MECHANICAL DRAWINGS AND THE MECHANICAL CONTRACTOR FOR THE EXACT LOCATION AND REQUIREMENTS OF ALL MECHANICAL EQUIPMENT PRIOR TO WORK.G. REFER TO MECHANICAL EQUIPMENT CONNECTION SCHEDULE ON SHEET 1-E0.2 FOR ELECTRICAL REQUIREMENTS. H. EXISTING BREAKERS SERVING CIRCUITS COMPLETELY DEMOLISHED MAY BE REUSED TO SERVE NEW CIRCUITS. I. FIRE ALARM DEVICES SHOWN ON THIS SHEET ARE NEW. GENERAL NOTESSHEET KEYNOTESX1. PROVIDE 120V CIRCUIT FOR UNDERCOUNTER LED LIGHT FIXTURE TYPE 'U'. UNDERCOUNTER LIGHTS TO EXTEND THE ENTIRE PERIMETER OF BARTOP. LIGHTS TO BE CONTROLLED BY ADJACENT WALL MOUNTED DIMMER SWITCH. REFER TO LIGHT FIXTURE SCHEDULE FOR GENERAL REQUIREMENTS. COORDINATE EXACT INSTALLATION REQUIREMENTS, MOUNTING HEIGHT AND LENGTHS WITH INTERIOR AND ARCHITECTURAL DRAWINGS PRIOR TO ROUGH-IN.2. PROVIDE 120V CIRCUIT FOR BAR TELEVISIONS AND DISPLAY LIGHTING. PROVIDE JUNCTION BOX ABOVE CEILING FOR CONNECTION TO DISPLAY LIGHTING. COORDINATE EXACT LOCATIONS, REQUIREMENTS AND MOUNTING HEIGHTS WITH FOOD SERVICE, INTERIORS AND ARCHITECTURAL DRAWINGS PRIOR TO ROUGH-IN.3. PROVIDE UNDERCOUNTER PLUG MOLD FOR ENTIRE PERIMETER OF BARTOP. COORDINATE EXACT INSTALLATION REQUIREMENTS, MOUNTING HEIGHT AND LENGTHS WITH INTERIOR AND ARCHITECTRUAL DRAWINGS PRIOR TO ROUGH-IN.4. PROVIDE COMBINATION DUPLEX RECEPTACLE/USB OUTLET IN UNDERCOUNTER PLUG MOLD FOR EVERY DEVICE SHOWN ON THIS CIRCUIT (TYPICAL OF 7).5. NEW LOCATION FOR ELECTRICAL CHASE CLOSET. SPLICE AND EXTEND ALL CIRCUITING TO NEW LOCATION AS NEEDED.6. ALL DEVICES AND COVERPLATES IN THIS ROOM ARE TO BE SMOOTH BLACK.7. TO BE MOUNTED IN FACE OF LOUVERED MILLWORK SOFFIT. COORDINATE EXACT LOCATION WITH INTERIOR DRAWINGS PRIOR TO ROUGH-IN.