ABCC P2 - Bldg 1 - 1-M0.11_1MVD MVDMVD MVDMVD VERTICAL RETURN DUCT VERTICAL SUPPLY DUCT 90° ELBOW WITH TURNING VANES IN SUPPLY DUCTWORK MVD FLEXIBLE DUCTWORK MANUAL VOLUME DAMPER 45° CLINCH COLLAR DIFFUSER RUNOUT SUPPLY RETURN OR EXHAUST EQUAL TO REQ'D BRANCH DUCT DIMENSIONS 1/4 BRANCH DUCT WIDTH, BUT MIN. 4" 1" MIN. ON TOP AND BOTTOM 45° MAIN DUCT SEAL ALL AROUND EQUAL TO REQ'D BRANCH DUCT DIA. ADJUSTABLE ELBOW RINGS 45° 1" MIN. ON TOP AND BOTTOM MAIN DUCT SUPPL Y AIRFLO W SEAL ALL AROUND PLAN OR SIDE VIEW AIR FLOW 20° MAX. 20° MAX. PLAN OR SIDE VIEW 30° MAX. EQUIPMENT 30° MAX. 15° MAX. 15° MAX. NOTE: 1.UNLESS OTHERWISE INDICATED ON PLANS, MAXIMUM ANGLES SHOWN SHALL APPLY. L L BALANCING DAMPER (BD.) WHERE INDICATED ON DRAWING. MINIMUM OF 1 DUCT DIA. FROM MAIN DUCT THEN ONLY WHERE ROUND RUNOUTS ARE INDICATED ON DRAWINGS ROUND RECTANGULAR BRANCH DUCTL=W/4 (4" MIN.) 45° W MAIN DUCT USE ONLY AT LAST TAKEOFF BEFORE OUTLETS & THEN ONLY WHERE RECTANGULAR RUNOUTS ARE INDICATED ON DRAWINGS BALANCING DAMPER (BD.) WHERE INDICATED ON DRAWING. MINIMUM OF 1 DUCT DIA. FROM MAIN DUCT BRANCH DUCT L=W/4 (4" MIN.) W 45° MAIN DUCT BALANCING DAMPER (BD.) WHERE INDICATED ON DRAWING. MINIMUM OF 1 DUCT DIA. FROM MAIN DUCT BRANCH DUCT D-3/4 D HEEL R45° MAIN DUCT STRAIGHT MAY BE USED ANYWHERE 3/4 D THROAT RADIUS NYLON DRAW BAND AROUND INNER LINER, TYP. EXTERNAL INSULATION TITUS 'FLEXRIGHT' 90° ELBOW. OPPOSED BLADE DAMPER (O.B.D), SEE NOTE 2. PROVIDE EXTENDED ACTUATOR SHAFT SUPPLY DUCT SPIN-IN TAP FITTING W/AIR SCOOP & DAMPER T-BAR TYPE SUSPENDED CEILING PULL INSULATION OVER SPIN-IN TO SUPPLY DUCT. TAPE AND SEAL AT DUCT MAIN INSULATION SEAL. TIE OFF TO STRUCTURE ABOVE METAL BAND SUPPORT FLEX DUCT WITH INTEGRAL INSULATION MAX. LENGTH 6'-0" NOTES: 1. INSTALLATION IS SIMILAR FOR LINEAR SLOT DIFFUSERS AND DIFFUSERS INSTALLED IN GYPSUM CEILING. 2. PROVIDE MANUAL REMOTE DAMPER CONTROLLERS FOR BALANCING DAMPER OPERATORS INSTALLED ABOVE NON-ACCESSIBLE CEILINGS OR AREAS. YOUNG MODEL 1200-FS W/ YOUNG MODEL 301-FS CONCEALED CUP AND COVER OR APPROVED EQUAL. LAY-IN SUPPLY AIR DIFFUSER W/ ROUND NECK & O.B.D. CEILINGR.A. GRILLE FULL SIZE OF GRILLE TURNING VANES SEE FLOOR PLAN FOR EXACT SIZE ROTATION (90 DEG) 2" 12" MAX. ROD POSITIONING NUT HANDLE WITH SET SCREW ALIGN HANDLE WITH DAMPER BLADE BLADE POSITION LOCKNUT 2" STAND-OFF BRACKET, BOLT TO DUCT 3/8" DIA. THREADED ROD 16 GA. STEEL BLADE STEEL ANGLE BLADE STOP, BOLT TO DUCT 1/4" CLEARANCE ALL-AROUND DUCT BEARING FITTING, BOLT TO DUCT ENSURE BOLTS CLEAR BLADE, OR INSTALL THEM IN OPPOSING CORNERS AWAY FROM BLADE ROTATION STEEL CLAMP, BOLT TO BLADE, PROVIDE AN ADDITIONAL ANTI-SLIP BOLT THRU THE RODNOTES: 1.DAMPERS FOR ROUND DUCTS SHALL BE SIMILAR TO THE DAMPER SHOWN ABOVE. 2.ENSURE THAT FULL 90° DAMPER BLADE MOVEMENT IS UNOBSTRUCTED. 3. FOR DUCT HEIGHTS MORE THAN 12", PROVIDE FACTORY-FABRICATED OPPOSED BLADE DAMPERS "A" "A" SECTION "A-A" ACCESS DOOR "B""B" SECTION "B-B" ACCESS PANEL 2" W.G. STATIC AND LESS 3" W.G. STATIC 4" W.G. 10" W.G. S = SIDE OPPOSITE HINGES, T = TOP, B = BOTTOM 12" x 12" 16" x 20" 24" x 24" 12" x 12" 16" x 20" 24" x 24" 12" x 12" 16" x 20" 24" x 24" SIZE NO. HINGES 2 2 3 2 2 3 2 3 3 1-S 2-S 2-S 1-S 1-S,1-T,1-B 2-S,1-T,1-B 1-S,1-T,1-B 2-S,1-T,1-B 2-S,2-T,2-B BACK 24 22 22 22 20 20 20 18 18 26 24 22 22 20 20 20 18 18 26 26 26 26 26 24 26 24 24 METAL GAGENO. LOCKS DOOR TO INSULATION DUCT GASKET CASING GASKET HANDLE INSIDE FLEXIBLE WASHER FACTORY FABRICATED LATCH INSULATION 1. LATCHES SHALL BE OF THE WEDGE TYPE TO CLOSE DOORS TIGHTLY. 2. HINGES ON THE ACCESS DOORS SHALL HAVE NON-CORROSIVE PINS. 3. PROVIDE ACCESS DOORS IN MER. PROVIDE ACCESS PANELS FOR ALL OTHER LOCATIONS. 4. PROVIDE LOCKS IN LIEU OF HINGES IN A EQUAL QUANTITY DEFINED IN THE NO. LOCKS COLUMN FOR LOCKS 'SIDE OPPOSITE HINGES' FOR ACCESS PANEL INSTALLATIONS. NOTES: DOORFRAME 3"-4" (10" MAX.) DUCT FIRE RESISTANT RUBBER IMPREGNATED FABRIC 1-1/2" POCKET SLIPSHEET METAL SCREWS ON 4" CENTERS 1" x 1/8" BAND IRON FAN INLET/OUTLET 20 U.S. GAGE STEEL 20 U.S. GAGE STEEL 6" (152) MIN. 9 3 2 1 5 8 9 6 4 7 1" (25) MIN. TYPICAL OVERLAP ON ALL SIDES OF DAMPER 1/4" (6) MIN. 5 1 2 9 3 7 4 6 8 9 DUCT DUCT WALL INSTALLATION DETAIL IS SPECIFIC TO RUSKIN FSD60 COMBINATION FIRE AND SMOKE DAMPER. FOR OTHER DAMPERS, REFER TO CORRESPONDING MANUFACTURER'S INSTALLATION DETAILS. 1. ACTUATOR (LOCATION MAY VARY). DAMPER MAY BE SUPPLIED WITHOUT ACTUATOR INSTALLED. RUSKIN'S UL LISTED FIRE DAMPER ACTUATORS MAY BE FIELD INSTALLED IF PROPERLY LABELED. SEE ACTUATOR INSTALLATION INSTRUCTIONS FOR FIELD MOUNTING OF DAMPER ACTUATORS. 2. OPTIONAL FIRESTAT OR SP100 3. AUXILIARY OPERATING JACK SHAFT 4. DAMPER 5. OVER CENTER LOCK 6. SLEEVE 7. CAULKING MATERIAL (MAY BE ON EITHER SIDE OF DAMPER FRAME) 8. PFMA OR CONVENTIONAL MOUNTING ANGLES 9. S-JOINT/DUCT MATE, SLEEVE TO DUCT ITEM DESCRIPTION VERTICAL INSTALLATION TYPICAL AIRFOIL INSTALLATION HORIZONTAL INSTALLATION ACTUATOR BELOW FLOOR 1/4" (6) MIN. 1" (25) MIN TYPICAL OVERLAP ON ALL SIDES OF DAMPER 6" (152) MIN. 16" (406) MAX. TYP. SD AIRFLOW DIRECTION AIRFLOW INLET RETURN AIR IN DUCT TURN OR OFFSET MINIMUM CLEARANCE FROM AIR INLETMINIMUM CLEARANCE FROM AIR OBSTRUCTIONS SD SD TOP VIEW RUBBER CAP RETURN TUBE; SLANT CUT FACE ORIENTED DOWNSTREAM OF AIR FLOW ELECTRIC POWER SUPPLY INLET TUBE HOLES ORIENTED UPSTREAM OF AIR FLOW TUBE SUPPORT HOLE FOR DUCTS MORE THAN 36" WIDE 6 DUCT WIDTHS MINIMUM 6 DUCT WIDTHS MINIMUM NOTES: 1.INLET TUBE LENGTH SHALL BE EQUAL TO FULL WIDTH OF DUCT. 2.RETURN TUBE SHALL BE AS RECOMMENDED BY THE DETECTOR'S MANUFACTURER. 3.CLEARANCES FROM OBSTRUCTIONS, INLETS AND PROPER LOCATION IN THE SYSTEM SHALL BE IN ACCORDANCE WITH NEMA: "GUIDE FOR PROPER USE OF SMOKE DETECTORS IN DUCT APPLICATIONS", NFPA90A, U.L. STANDARD 268A AND NFPA 72E. NOTES: 1.ADJUST VOLUME DAMPERS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS FOR SPECIFIED AIR FLOW. 2.REFER TO DIFFUSER SCHEDULE FOR QUANTITY AND SIZES OF SLOTS. 3.SUPPORT FLEXIBLE DUCTWORK AS INDICATED ON LAY-IN DIFFUSER INSTALLATION DETAIL. PATTERN CONTROLLER SCREW HANGER BRACKET 1/2" SOUNDLINING VOLUME DAMPER SHEET METAL PLENUM; SIZE AS INDICATED ON DRAWINGS ROUND NECK INSULATED FLEXIBLE DUCT 1/2" STAINLESS STEEL DRAWBAND CEILING DESIGNER'S NOTES: FOR ROUND NECK CEILING DIFFUSERS USE SPLITTER DAMPER ONLY WHEN SPACE BETWEEN BOTTOM OF DUCT AND CEILING DOES NOT PERMIT INSTALLATION OF MULTI-BLADE VOLUME DAMPER. WHEN BOTH SPLITTER DAMPER AND MULTI-BLADE VOLUME DAMPERS ARE REQUIRED, INDICATE ON FLOOR PLANS WHERE SPLITTER DAMPER VOLUME CONTROL IS REQUIRED. SUPPLY DUCT CONTROL GRID SUPPLY DUCT CONTROL GRID SPLITTER DAMPER WITH CENTER ROD OPERATOR CEILING CEILING MULTI-BLADE DAMPER FOR ROUND NECK DIFFUSER & OPPOSED BLADE DAMPER FOR SQUARE NECK DIFFUSER SIDE VIEW ROUND NECK CEILING DIFFUSER TAKE-OFF SIDE VIEW ROUND AND/OR SQUARE NECK CEILING DIFFUSER TAKE-OFFS DRAWN BY: PROJECT NO.: SCALE: REVISION NO.DATE DESCRIPTION THE INFORMATION SHOWN ON THESE DRAWINGS IS OWNED BY AND IS THE PROPERTY OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. NO PART THEREOF SHALL BE COPIED, ADAPTED, OR DISTRIBUTED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. COPYRIGHT © 2023 26560 AGOURA ROAD, SUITE 106 CALABASAS, CA 91302 310.670.9144 A S S O C I A T E S ARCHITECTS + ENGINEERS S H E P P H I R D will.s@shep-ae.com 1 12-02-22 SD PRICING 2 2-10-23 DD PRICING 3 9-07-23 PHASE 2 90% CD Atlantic Beach Country Club Phase 2 Construction Documents 1600 Selva Marina Drive Atlantic Beach, FL 32233 12" = 1'-0" 1-M0.11PHASE 2 -MAIN CLUBHOUSE MECHANICALDETAIL2022-352 Author 12" = 1'-0"1-M0.11 DUCT CONSTRUCTION DETAIL1 N.T.S.1-M0.11 2 TYPICAL BRANCH TAKE-OFF FITTING N.T.S.1-M0.11 3 TYPICAL DUCT ENLARGEMENT/REDUCTION TRANSITION N.T.S.1-M0.11 4 TYPICAL MAIN TO BRANCH DUCT CONNECTIONS N.T.S.1-M0.11 5 SUPPLY AIR DIFFUSER DETAIL N.T.S.1-M0.11 6 DUCT CONNECTION TO RETURN AIR GRILLE N.T.S.1-M0.11 9 MANUAL SINGLE BLADE BALANCING DAMPER DETAIL N.T.S.1-M0.11 11 DUCT ACCESS DOORS N.T.S.1-M0.11 10 TYPICAL AIRSIDE FLEXIBLE EQUIPMENT CONNECTION DETAIL N.T.S.1-M0.11 12 FIRE/SMOKE DAMPER INSTALLATION DETAIL N.T.S.1-M0.11 13 DUCT MOUNTED SMOKE DETECTOR DETAIL N.T.S.1-M0.11 7 LINEAR SLOT DIFFUSER INSTALLATION DETAIL N.T.S.1-M0.11 8 CEILING DIFFUSER TAKE-OFF