Loading...
ABCC P2 - Bldg 1 - 1-M0.12_1DRYER EXHAUST WALL BOX - REFER TO PLANS FOR EXACT LOCATIONDRYER BY: ABCC EXTEND 4"∅DRYER EXHAUST DUCT THRU DRYER EXHAUST BOX TO ALLOW CONNECTION FOR FLEXIBLE DRYER HOSE 4"∅DRYER EXHAUST DUCT SHALL BE MINIMUM 26 GAUGE FLEXIBLE DRYER HOSE BY INSTALLER SECURE EXHAUST BOX TO WALL PER MANUFACTURER' S RECOMMENDATIO NS METAL FLANGE ROUTE DRYER EXHAUST DUCT TO EXTERIOR WALL IN THE MOST DIRECT MANNER POSSIBLE NOTES: 1.LAST 10' OF EXHAUST DUCT SHALL BE SLOPED DOWN TOWARDS BUILDING EXTERIOR. INTERIOR PARTITION WALL HAVING ADEQUATE DEPTH FOR INSTALLATION OF VENT BOX FINISHED FLOOR DRYER VENT BOX -SEE DETAIL TOP PLATE SHALL BE CUT AND FIRESTOPPED USING APPROVED FIRESTOP MATERIAL 4"∅EXHAUST DUCT UP THRU TOP PLATE AND INTO TRUSS SYSTEM SEE NOTE 1 WARNING- RISK OF FIRE THE CLOTHES DRYER'S INSTALLED MAXIMUM EXHAUST LENGTH AS SHOWN IN THE INSTALLATION INSTRUCTIONS MUST EXCEED THE TOTAL SYSTEM EQUIVALENT LENGTH INDICATED BELOW DRYER CONNECTION MUST BE UL LISTED 4" ROUND FLEX DUCT TOTAL SYSTEM EQUIVALENT LENGTH = XX'-X" PRE-DRILLED HOLESRED PLASTIC BACKGROUND WITH ENGRAVED 1/8" (MIN) HIGH WHITE LETTERS 5/16" (MIN) HIGH WHITE LETTERS NOTES: 1.PERMANENTLY AFFIX THE LABEL IN A CONSPICUOUS LOCATION WITHIN SIX (6) LINEAL FEET OF THE EXHAUST CONNECTION. 2.LABEL ABOVE IS SHOWN AS A GUIDELINE ONLY. ALTERNATE DESIGNS MAY BE SUBMITTED FOR REVIEW. CONTRACTOR: INSERT THE ACTUAL FIELD MEASURED DISTANCE ACTUAL INSTALLED EQUIVALENT LENGTH FROM THE DRYER CONNECTION TO THE EXTERIOR VENT CAP 3" MIN 6" MIN 8" MINIMUM RIGID INSULATION BUILT-UP ROOF PREFABRICATED ROOF CURB MECHANICAL EQUIPMENT 3" FIBER CANT BAR JOISTS GALV. ROOF DECK PUDDLE WELD TO BAR JOISTS TEK SCREW OR TACK WELD @ 12" O.C. TOP OF CURB SHALL BE LEVEL REFER TO STRUCTURAL AND ARCHITECTURAL DRAIWINGS FOR ADDITIONAL REQUIREMENTS. 8" MIN. 3" FIBER CANT PREFABRICATED EQUIPMENT SUPPORT. 18 GA. GALV. W/ INTERNAL GUSSETS @ 24" O.C. 2 X 6 P.T. WOOD NAILER GALV. ROOF DECK BAR JOISTS HVAC EQUIPMENT BUILT-UP ROOF PUDDLE WELD CURB FLANGE TO BAR JOISTS TEK-SCREW OR TACK WELD @ 12" O.C. INSULATION 18 GA. COUNTERFLASHING TOP OF CURB SHALL BE LEVEL REFER TO STRUCTURAL AND ARCHITECTURAL DRAWINGS FOR ADDITIONAL REQUIREMENTS. ROUTE TO EXHAUST FAN (RE: FLOOR PLANS FOR SIZE AND ROUTING) SLOPE OUTERMOST 10' DOWN TOWARD WALL CAP AS AN OPTION TO THE BROAN WALL CAP WITH SPRING LOADED BDD, PROVIDE AN AMERICAN ALDES SPRING LOADED BACKDRAFT DAMPER -AIRFLOW DIRECTION SHALL BE MARKED ON THE OUTSIDE OF THE DAMPER PRIOR TO INSTALLATION TO VERIFY PROPER AIRFLOW DIRECTION. INSTALL SO THAT BDD CAN BE ACCESSED THRU WALL CAP HOOD WALL CAP WITH GASKETED SPRING LOADED BACKDRAFT DAMPER AND BIRD SCREEN - 3" OR 4" DUCT: BROAN MODEL 885; 6" DUCT: BROAN MODEL 641 OR APPROVED EQUAL NOTES: 1. WALL CAP SHALL BE THE SAME SIZE AS THE EXHAUST DUCT - REFER TO FLOOR PLANS FOR SIZE. 2. WALL CAP SHALL BE ALUMINUM OR GALVANIZED STEEL WITH PAINT GRIP COATING FOR FIELD PAINTING (FIELD PAINTING BY OTHERS). 3. WALL CAP AND BDD SHALL BE ALUMINUM CONSTRUCTION FOR SEACOAST LOCATIONS. 4"∅DRYER EXHAUST DUCT - ROUTE TO DRYER EXHAUST WALL BOX (RE: FLOOR PLANS FOR ROUTING). SLOPE OUTERMOST 10' DOWN TOWARD WALL CAP AMERICAN ALDES CAPE BACKDRAFT DAMPER WIDE MOUTH HOODED WALL CAP WITH BACKDRAFT DAMPER; GE MODEL PM8X85D5 (WITH BDD REMOVED) OR APPROVED EQUAL NOTES: 1. WALL CAP SHALL BE THE SAME SIZE AS THE EXHAUST DUCT. 2. WALL CAP SHALL BE ALUMINUM OR GALVANIZED STEEL WITH PAINT GRIP COATING FOR FIELD PAINTING (FIELD PAINTING BY OTHERS). 3. WALL CAP AND BDD SHALL BE ALUMINUM CONSTRUCTION FOR SEACOAST LOCATIONS. TYPICAL KITCHEN EXHAUST NOTES 1.SEE PLANS FOR LOCATIONS, SIZES & ROUTING. 2.ENTIRE KITCHEN EXHAUST SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH UL762, NFPA 96, AND THE 2012 INTERNATIONAL MECHANICAL CODE. 3.CLEAN-OUTS AND ACCESS DOORS SHALL MAINTAIN SYSTEM FIRE RESISTANCE RATING. 4.INSTALLERS OF FIRE RATED DUCTWRAP SHALL BE TRAINED AND CERTIFIED AS A QUALIFIED INSTALLER BY THE MANUFACTURER. KITCHEN EXHAUST DUCT WRAP SPECIFICATION (TYPICAL FOR ALL KITCHEN HOOD EXHAUST DUCTWORK) SUMMARY WORK OF THIS SECTION INCLUDES LABOR, MATERIAL, AND EQUIPMENT TO PROVIDE A TWO (2) HOUR FIRE RESISTIVE RATED GREASE OR AIR DUCT ENCLOSURE AS A SHAFT ALTERNATIVE AND A METHOD FOR PROVIDING ZERO INCH CLEARANCES AROUND COMMERCIAL KITCHEN GREASE DUCT EXHAUST SYSTEMS TO COMBUSTIBLE MATERIALS. PRODUCT SHALL BE AS EQUAL TO "3M 615+" DUCTWRAP. SYSTEM DESCRIPTION A LIGHTWEIGHT NON-ASBESTOSE, HIGH TEMPERATURE, INORGANIC, CERAMIC FIBER BLANKET TOTALLY ENCAPSULATED IN FOIL / SCRIM HAVING A SERVICE TEMPERATURE RANGE UP TO 2300°F. 3M 615+ DUCT WRAP IS DIRECTLY APPLIED TO COMMERCIAL GREASE HOOD EXHAUST DUCT SYSTEMS AND AIR DUCT SYSTEMS TO ALLOW A ZERO INCH CLEARANCE TO COMBUSTIBLE CONSTRUCTION AND TO PROVIDE A TWO (2) HOUR FIRE RESISTIVE DUCT ENCLOSURE. DUCT WRAP, IN CONJUNCTION WITH UL LISTED AND APPROVED THROUGH PENETRATION FIRESTOP SYSTEMS SHALL BE RATED AS AN ALTERNATIVE TO RIGID SHAFT ENCLOSURES. 3M 615+ DUCT WRAP IS APPLIED IN A CONTINUOUS WRAP FROM THE POINT THE DUCT ENTERS A CONCEALED SPACE TO ITS EXIT FROM A BUILDING. SYSTEM INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS TO MAINTAIN A TWO HOUR FIRE RATING FOR THE ENTIRE SYSTEM. PERFORMANCE REQUIREMENTS -TWO-HOUR RATED FIRE RESISTIVE ENCLOSURE ASSEMBLY, ASTM E119: LARGE SCALE WALL PANEL TEST AND TOTAL ENGULFMENT TEST. -ZERO INCH CLEARANCE TO COMBUSTIBLE, MAXIMUM ALLOWABLE SURFACE TEMPERATURE ON UNEXPOSED SIDE, UL 1978. -CLASS I INTERIOR FINISH MATERIALS, ASTM E84. -THROUGH-PENETRATION PROTECTION SYSTEMS FOR GREASE AND AIR DUCTS, ASTM E814 AND UL 1479. -NON-COMBUSTIBILITY, ASTM E136 . -ISO-6944-1985, FIRE RESISTANCE TESTS -VENTILATION DUCTS. REQUIRED REFERENCES, RATINGS, & APPROVALS 1.UL FILE R9242 2.UL1978 STANDARD FOR GREASE DUCTS 3.UL723 SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS 4.UL263 FULL SCALE ENGULFMENT 5.UL1479 THROUGH-PENETRATION FIRESTOPS 6.NFPA 96-2012 FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS. 7.IMC 506.12 (2012) DUCT ENCLOSURE KITCHEN EXHAUST HOOD SEE PLANS KITCHEN EXHAUST HOOD AND CONTROLLER BY KITCHEN EQUIPMENT SUPPLIER 18" MIN. 40" MIN. DRAIN CONNECTION AND GREASE COLLECTOR BY FAN MANUFACTURER ROOF 10 Ga. SLEEVE WITH ANGLE FRAME. CONNECTION TO HOOD EXHAUST COLLAR SHALL BE PER NFPA 96 PROVIDE CLEAN-OUTS & INSULATION PER CHAPTER 5 OF THE 1996 INTERNATIONAL MECHANICAL CODE. SEE PLANS FOR LOCATIONS 16Ga. BLACK WELDED STEEL DUCT IN ACCORDANCE WITH CHAPTER 5 OF THE 1996 INTERNATIONAL MECHANICAL CODE. (TYPICAL) PROVIDE CLEAN-OUTS AND INSULATION AS SHOWN AT ALL 90° BENDS, BASE OF RISER, AND FLOOR PENETRATIONS (TYPICAL) KITCHEN HOOD EXHAUST DUCTS TO BE FULLY WRAPPED WITH "3M 615+" TO PROVIDE A 2 HR. RATED, ZERO CLEARANCE TO COMBUSTIBLE SYSTEM. SEE SPECIFICATION THIS SHEET FOR DETAILS. (TYPICAL) KITCHEN EXHAUST DUCT RISER UP IN CEILING SPACE. SEE PLANS FOR SIZE AND LOCATION 3M 615+ DUCT WRAP CONTINUOUS THROUGH FLOOR. SEAL WITH FIRE RATED CAULK AND 'PYROSCAT' INSULATION IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND UL LISTING (TYPICAL) ROOFING, FLASHING, AND COUNTER-FLASHING BY G.C. (TYPICAL) VENTED EXTENSION CURB 16 GA. STEEL DUCT ALL JOINTS WELDED LIQUID TIGHT. HINGED BASE EXHAUST FAN DRAWN BY: PROJECT NO.: SCALE: REVISION NO.DATE DESCRIPTION THE INFORMATION SHOWN ON THESE DRAWINGS IS OWNED BY AND IS THE PROPERTY OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. NO PART THEREOF SHALL BE COPIED, ADAPTED, OR DISTRIBUTED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. COPYRIGHT © 2023 26560 AGOURA ROAD, SUITE 106 CALABASAS, CA 91302 310.670.9144 A S S O C I A T E S ARCHITECTS + ENGINEERS S H E P P H I R D will.s@shep-ae.com 1 12-02-22 SD PRICING 2 2-10-23 DD PRICING 3 9-07-23 PHASE 2 90% CD Atlantic Beach Country Club Phase 2 Construction Documents 1600 Selva Marina Drive Atlantic Beach, FL 32233 12" = 1'-0" 1-M0.12PHASE 2 -MAIN CLUBHOUSE MECHANICALDETAIL2022-352 Author N.T.S.1-M0.12 1 DRYER WALL BOX N.T.S.1-M0.12 2 DRYER EXHAUST DUCTING N.T.S.1-M0.12 3 DRYER EXHAUST VENT WARNING LABEL N.T.S.1-M0.12 5 ROOF CURB INSTALLATION DETAIL N.T.S.1-M0.12 6 ROOF MOUNTED EQUIPMENT INSTALLATION DETAIL N.T.S.1-M0.12 7 BATHROOM WALL CAP N.T.S.1-M0.12 8 DRYER WALL CAP N.T.S.1-M0.12 4 GREASE EXHAUST DUCT INSTALLATION DETAIL N.T.S.1-M0.12 10 MECHANICAL BASE FLASHING AT CURB OR OPENING N.T.S.1-M0.12 9 MECHANICAL PENETRATION N.T.S.1-M0.12 11 MECHANICAL HVAC SUPPORT JOIST N.T.S.1-M0.12 12 MECHANICAL GOOSENECK SHROUD