Loading...
ABCC P2 - Bldg 1 - 1-M2.1_1DryerWasherBREEZEWAY 010A WOMEN'S POOL RESTROOM 145 MEN'S POOL RESTROOM 142 VESTIBULE 141 VESTIBULE 144 ACCESSIBLE RESTROOM 142D ACCESSIBLE RESTROOM 145E SHOWER 145F SHOWER 142E AQUATICS STAFF 138 LAUNDRY 137 STORAGE 132E STORAGE 132D CATERING DIR. / TBD 132C DRY STORAGE 1 132A MECHANICAL SERVICE 131H CORRIDOR 132 COOLER 131F BEER COOLER 131D FREEZER 131E BAKE SHOP 131B BREAK ROOM 133 RR 134 RR 135 FCU 4 OFFICE, TBD 132B BAR PANTRY 131L OUTSIDE SERVICE SNACK BAR 131K BEER / WINE COOLER 131M CHEF & SOUSE CHEF 131A KITCHEN 131 FOOD & BEVERAGE OFFICE 131IWASH STATION 131J ELECTRICAL SERVICE 131G DRY STORAGE 131C CORRIDOR 131N RH 1-1 RH 1-7 RH 1-8 HP 2A HP 2B HP 9 HP 3 HP 4 HP 6 HP 7 HP 5 DHP 1 FCU 1 FCU 2 FCU 3 BS 1 TO KSF-1 ON ROOF TO KSF-2 ON ROOF TO RTU-1 ON ROOF TO DOAS-1 ON ROOF TO KEF-4 ON ROOF TO KEF-2 ON ROOF TO KEF-1 ON ROOF CORRIDOR 136 8x6 OUTSIDE AIR FROM BELOW UH 1 1-M4.1 1 1-M4.1 2 1-M4.2 1 EF 3B EF 1 EF 3A EF 2 EF 5B EF 5A EF 8 EF 9/11-M4.1/11-M4.2/11-M4.1/11-M4.2/1 1-M4.1 /2 1-M4.1 /1 1-M4.1 /2 1-M4.1 RH 1-2 RH 1-3 RH 1-4 RH 1-5 RH 1-6 (EXISTING) (EXISTING) (EXISTING) (EXISTING) (EXISTING) (EXISTING) (EXISTING) (EXISTING) (EXISTING) (EXISTING) 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION. ANY CONFLICTS AND DISCREPANCIES SHALL NOTIFY THE ARCHITECT PRIOR TO THE CONSTRUCTION START. 2. DUCTWORK SHALL MOUNT AS HIGH AS POSSIBLE TO MAXIMIZE THE CEILING SPACE. 3. PROVIDE MANUFACTURER'S CLEARANCE AROUND ALL ABOVE CEILING MECHANICAL EQUIPMENT. 4. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPE. 5. PROVIDE REMOTE BALANCING DAMPERS FOR ANY NON-ACCESSIBLE DIFFUSERS. 6. PROVIDE CEILING ACCESS PANEL FOR ANY NON-ACCESSIBLE CEILING EQUIPMENT AND DAMPERS. 7. EXHAUST OUTLETS SHALL BE LOCATED MININUM 10'-0" HORIZONTALLY OR 3'-0" ABOVE ANY BUILDING OPENING AND INTAKE OPENING. 8. VERIFY EXISTING LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, AND SYSTEM COMPONENTS PRIOR TO DEMOLITION. IF EXISTING CONDITIONS ARE DIFFERENT THAN WHAT IS INDICATED ON THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE OWNER/ARCHITECT PRIOR TO PROCEEDING WITH WORK. 9. WHERE TEMPORARY SHUTDOWN OF SERVICES IS NEEDED FOR AREAS THAT WILL BE OCCUPIED DURING CONSTRUCTION, THE SHUTDOWN SHALL BE CLOSELY COORDINATED WITH OWNER. ARRANGE WORK TO ASSURE THAT ANY SHUTDOWN OF SERVICES TIME IS AS MINIMAL AS POSSIBLE. GENERAL NOTES DRAWN BY: PROJECT NO.: SCALE: REVISION NO.DATE DESCRIPTION THE INFORMATION SHOWN ON THESE DRAWINGS IS OWNED BY AND IS THE PROPERTY OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. NO PART THEREOF SHALL BE COPIED, ADAPTED, OR DISTRIBUTED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. COPYRIGHT © 2023 26560 AGOURA ROAD, SUITE 106 CALABASAS, CA 91302 310.670.9144 A S S O C I A T E S ARCHITECTS + ENGINEERS S H E P P H I R D will.s@shep-ae.com 1 12-02-22 SD PRICING 2 2-10-23 DD PRICING 3 9-07-23 PHASE 2 90% CD Atlantic Beach Country Club Phase 2 Construction Documents 1600 Selva Marina Drive Atlantic Beach, FL 32233 As indicated 1-M2.1PHASE 2 -MAIN CLUBHOUSE OVERALLMECHANICAL PLAN -LEVEL 12022-352 Author1/8" = 1'-0"1-M2.1 PHASE 2 - MAIN CLUBHOUSE OVERALL MECHANICAL PLAN - LEVEL 11