Loading...
ABCC P2 - Bldg 1 - 1-M4.1_1Dryer Washer BREEZEWAY 010A WOMEN'S POOL RESTROOM 145 MEN'S POOL RESTROOM 142 VESTIBULE 141 VESTIBULE 144 ACCESSIBLE RESTROOM 142D ACCESSIBLE RESTROOM 145E SHOWER 145F SHOWER 142E AQUATICS STAFF 138 LAUNDRY 137 STORAGE 132E STORAGE 132D CATERING DIR. / TBD 132C DRY STORAGE 1 132A MECHANICAL SERVICE 131H CORRIDOR 132 COOLER 131F BEER COOLER 131D FREEZER 131E BAKE SHOP 131B BREAK ROOM 133 RR 134 RR 135 A 250 A 250 20"x12" SA FCU 4 C 250 A 200 A 200 A 200 B 50 B 50 A 50 OFFICE, TBD 132B A 50 A 90 A 200 A 20014"x10" SA14"x10" SA 36"x10" RA 16"x10" SABAR PANTRY 131L OUTSIDE SERVICE SNACK BAR 131K BEER / WINE COOLER 131M CHEF & SOUSE CHEF 131A KITCHEN 131 FOOD & BEVERAGE OFFICE 131I WASH STATION 131J ELECTRICAL SERVICE 131G DRY STORAGE 131C A 120 A 225 A 225 CORRIDOR 131N A 100 A 100 A 200 A 130 A 500 28"x12" OA 12"x14" EA 42"x20" SA42"x20" SA36"x18" OA FCU 1 FCU 2 FCU 3 BS 120"x16" OATO KSF-1 ON ROOF TO KSF-2 ON ROOF TO RTU-1 ON ROOF TO DOAS-1 ON ROOF TO KEF-4 ON ROOF TO KEF-2 ON ROOF TO KEF-1 ON ROOF 42"x20" RA EXISTING 14"ø SA EXISTING 14"ø SA 8x6 OUTSIDE AIR TO LEVEL 2 22"x16" EA12"x14" EA10"x10" EA22"x16" EA22"x18" OA22"x18" OA28"x12" OA12"x10" OA12"x10" OAA 160 A 180 A 300 A 400 A 250 A 500 A 500 A 500 A 500 A 500 A 500 A 500A500 POOL STORAGE 140 34"x12" SA C 250 EF 8 EF 9 10"ø SA10"ø SA 10"ø RA 10"ø RA 6"ø SA 8"ø SA 12"x10" SA6"ø SA 26"x12" RA C -18"x6" OA18"x6" OA12"x12" OA 6"x8" SA6"ø SA 6"ø SA6"x4" OA6"x4" OAC - 8"x6" RA38"x6" RA C - 8"ø SA 8"ø SA 8"ø SA 8"ø EA6"ø EA 6"ø EA 10"x8" RA 10"x8" RA C - C - 12"x6" SA 12"x12" EA 10"x8" RA C - C -C -C -C - 12"ø SA 12"ø SA 12"ø SA12"ø SA12"ø SA10"ø SA8"ø SA8"ø SA10"ø SA10"ø SA6"ø SA12"x10" OA 10"x12" OA 12"x10" OA 12"x10" OA 16"x18" EA 26"x10" EA 16"x14" OA12"ø SA 14"x10" OA 14"x10" OA 14"x10" OA 14"x10" OA 20"x16" OA 18"x22" OA RRR DRRD 14"x10" SA12"x6" SA 12"x6" SA R DRRDCONNECT TO EXISTING CONDENSATE HOOD. FIELD VERIFY HOOD COLLAR SIZE AND LOCATION.22"x18" OAEF 5A EF 5B DINING HALL 125 TABLE STORAGE 129 HALL 128 PROVIDE A 32X40 CEILIG ACCESS PANEL /11-M4.2/11-M4.2/2 1-M4.1/2 1-M4.1 EXISTING 10"ø EA EXISTING 12"ø EAEXISTING 10"ø EA EXISTING 10"ø EA EXISTING 10"ø EA22 1 1 1 14"x6" RA 38"x8" RA8"ø SA8"ø SA8"ø SA WALL CAP WALL CAP4"ø EAEF 10 TO ROOF CAP T 10"x18" RH 1-6 REUSE EXISTING CEILING ACCESS PANEL REUSE EXISTING CEILING ACCESS PANEL FSD FSD R1 3 3 6"ø TA 6"ø TA E - 6"ø TA 6"ø TA E - E - E - E - E - E - E - 6"ø TA E - E - 6"ø TA E -E - 4 4 5 5 5 5 MVD MVD MVDMVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD MVD 12"x6" OA MVD MVD MVD MVD MVD MVD MVD T T T FCU-4 T FCU-2 MVD TFCU-1 TFCU-3 D SD SD SD SD 14"x12" OA RMVD MVD 34"x12" OA R D14"x12" OA EF-10 S H DP6 T RH 1-6 (2 STAGES HEAT SWITCH) S 8 14 T T 7 7 7 7 BAR PANTRY 131L A 120 A 225 RH 1-7 RH 1-8 POOL BAR 009 /1 1-M4.1 /1 1-M4.1 E -E - T T RH 1-7 (2 STAGES HEAT SWITCH)RH 1-8 (2 STAGES HEAT SWITCH) 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION. ANY CONFLICTS AND DISCREPANCIES SHALL NOTIFY THE ARCHITECT PRIOR TO THE CONSTRUCTION START. 2. DUCTWORK SHALL MOUNT AS HIGH AS POSSIBLE TO MAXIMIZE THE CEILING SPACE. 3. PROVIDE MANUFACTURER'S CLEARANCE AROUND ALL ABOVE CEILING MECHANICAL EQUIPMENT. 4. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPE. 5. PROVIDE REMOTE BALANCING DAMPERS FOR ANY NON-ACCESSIBLE DIFFUSERS. 6. PROVIDE CEILING ACCESS PANEL FOR ANY NON-ACCESSIBLE CEILING EQUIPMENT AND DAMPERS. 7. EXHAUST OUTLETS SHALL BE LOCATED MININUM 10'-0" HORIZONTALLY OR 3'-0" ABOVE ANY BUILDING OPENING AND INTAKE OPENING. 8. VERIFY EXISTING LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, AND SYSTEM COMPONENTS PRIOR TO DEMOLITION. IF EXISTING CONDITIONS ARE DIFFERENT THAN WHAT IS INDICATED ON THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE OWNER/ARCHITECT PRIOR TO PROCEEDING WITH WORK. 9. WHERE TEMPORARY SHUTDOWN OF SERVICES IS NEEDED FOR AREAS THAT WILL BE OCCUPIED DURING CONSTRUCTION, THE SHUTDOWN SHALL BE CLOSELY COORDINATED WITH OWNER. ARRANGE WORK TO ASSURE THAT ANY SHUTDOWN OF SERVICES TIME IS AS MINIMAL AS POSSIBLE. GENERAL NOTES 1. ROUTE 1" CONDENSER DRAIN LIN TO HUB DRAIN. REFER TO PLUMBING DRAWINGS. 2. NEW EXHAUST FAN TO REPLACE EXISTING ONE. CONTRACTOR TO FIELD VERIFY EQUIPMENT AND CEILING ACCESS PANEL LOCATION. PROVIDE NEW CEILING ACCESS PANEL IF REQUIRE FOR EQUIPMENT ACCESS. 3. CONTRACTOR TO FIELD VERIFY CLEAR AREA AT INTERSECTING TRUSSES FOR DUCT TO FIT THROUGH. 4. HORIZONTAL GREASE DUCT WITH 1/4" PER FOOT SLOPE TOWARD THE HOOD WITH 2- HOUR FIRE-RATED DUCT WRAP. INSTALL FIRE RATED DUCT WRAP PER MANUFACTURER INSTALLATION INSTRUCTION. 5. KITCHEN EXHAIUST HOOD BY OTHERS. PROVIDE 2-HOUR FIRE-RATED INSTALLATION ABOVE THE KITCHEN HOOD. 6. CONNECT DIFFERENTIAL PRESSURE SENSOR TO BAS GENERAL I/O PANEL. 7. COORDINATE THERMOSTAT LOCATION WITH OWNER. APPROVE BY ENGINEER. KEYNOTES DRAWN BY: PROJECT NO.: SCALE: REVISION NO.DATE DESCRIPTION THE INFORMATION SHOWN ON THESE DRAWINGS IS OWNED BY AND IS THE PROPERTY OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. NO PART THEREOF SHALL BE COPIED, ADAPTED, OR DISTRIBUTED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. COPYRIGHT © 2023 26560 AGOURA ROAD, SUITE 106 CALABASAS, CA 91302 310.670.9144 A S S O C I A T E S ARCHITECTS + ENGINEERS S H E P P H I R D will.s@shep-ae.com 1 12-02-22 SD PRICING 2 2-10-23 DD PRICING 3 9-07-23 PHASE 2 90% CD Atlantic Beach Country Club Phase 2 Construction Documents 1600 Selva Marina Drive Atlantic Beach, FL 32233 1/4" = 1'-0" 1-M4.1PHASE 2 -MAIN CLUBHOUSE MECHANICALPARTIAL PLAN -KITCHEN2022-352 Author1/4" = 1'-0"1-M4.1 PHASE 2 - MAIN CLUBHOUSE MECHANICAL PARTIAL PLAN - LEVEL 1 - KITCHEN1 PARTIAL PLAN1-M4.1 2 PHASE 2 - MAIN CLUBHOUSE MECHANICAL PARTIAL PLAN - LEVEL 1 - POOL BAR