Loading...
ABCC P2 - Bldg 1 - 1-M4.2_1KITCHEN 131 12"x12" EAEXISTING 16"x16" EAEXISTING 12"x12" EA EXISTING 12"x12" EA EXISTING 14"x12" EAEXISTING 16"x16" EAEXISTING 16"x16" SAEXISTING 10"x10" SAEXISTING 14"x14" SAEXISTING 12"x12" SAEXISTING 10"x10" EA EXISTING 10"x10" EA EXISTING 12"x12" SA EXISTING 14"x14" SA EXISTING 14"x14" RA EXISTING 16"x10" RA EXISTING 14"x12" SA EXISTING 10"x10" SAEXISTING 8"ø EAEXISTING 8"ø EA EXISTING 8"ø EAEXISTING 8"ø EAEXISTING 8"ø EAEXISTING 16"x16" SAEXISTING 14"x14" RAEXISTING 8"ø EAEXISTING 8"ø EAHP 2A HP 2B 20"x16" OA 18"x22" OA 20"x16" OAEXISTING 12"ø SAEXISTING 18"ø SA EXISTING 18"ø SA EXISTING 18"ø SA EXISTING 18"ø SA EXISTING 14"ø SA EXISTING 14"ø SA EXISTING 14"ø SA A 500 A 500 A 500 22"x18" OASHOWER 107ASHOWER 107B DRESSING 107C WOMEN'S SHOWERS 107 ACCESSIBLE RESTROOM 108A TOILET 108B TOILET 108C WOMEN'S RESTROOM 108 WOMEN'S PRIVATE RESTROOM 106 FDC / RISER 109 WOMEN'S LOCKERS 110 SHOWER 113D SHOWER 113C ACCESSIBLE RESTROOM 113B VESTIBULE 113E TOILET 113A PRIVATE VESTIBULE 111 SHOE SHINE AREA 112 MEN'S LOCKERS 123 ACCESSIBLE RESTROOM 117D TLT. 117C TLT. 117B TLT. 117A WOMEN'S RESTROOM 117 MEN'S RESTROOM 115 ACCESSIBLE RESTROOM 115C TLT. 115B URINALS 115A URINALS 115A DINING VESTIBULE 118 FOYER 100 MULTI-PURPOSE ROOM 126 DINING LOGGIA 124 DINING HALL 125 TABLE STORAGE 129 HALL 128 VESTIBULE 119 VESTIBULE 102 SERVICE BAR 116 BAR 120 EF 2 EF 1 EF 3A EF 3B /11-M4.1/11-M4.1UH 1 HP 9 HP 3 HP 4 HP 6 HP 7 HP 5 DHP 1 GRILLE 121 10"x18" RH 1-1 RH 1-2 RH 1-3 RH 1-4 RH 1-5 RH 1-6 EXISTING 10"x10" SA EXISTING 12"ø SA 160F A 160 30"x15" RA 8"ø SA 8"ø SA 8"ø SA 8"ø SA PROVIDE A 24X24 CEILING ACCESS PANEL PROVIDE A 24X24 CEILING ACCESS PANEL PROVIDE A 24X24 CEILING ACCESS PANEL PROVIDE A 24X24 CEILING ACCESS PANEL FSD FSD R3 3 MVD MVD 2 2 2 2 1 1 1 1 1 1 22"x18" OA TO AHU-3 TO AHU-4 TO AHU-5 TO AHU-6 TO AHU-5 TO AHU-7 TO AHU-2B TO AHU-2A MVD MVD MVD MVD MVD MVD MVD MVD C - C - 1 1 EXISTING 12"x12" SA EXISTING 14"x14" RA EXISTING 16"x16" SA EXISTING 14"x14" RA EXISTING 14"x14" RAEXISTING 16"x16" SA3 33 3 GOLF PRO SHOP 122 (EXISTING) (EXISTING) (EXISTING) (EXISTING) (EXISTING) (EXISTING) (EXISTING) (EXISTING) (EXISTING) DP 6 MVD MVD MVD MVD MVD 18"x28" SA21"x22" SA18"x18" SA10"x10" SAMVD MVD MVD MVD MVD MVD MVD MVD 8"ø SA 8"ø SA8"ø SA 8"ø SA 8"ø SA 8"ø SA 8"ø SA8"ø SA 8"ø SA 8"ø SA 8"ø SA 8"ø SA 8"ø SA 8"ø SA 8"ø SA 8"ø SA 8"ø SA 8"ø SA 8"ø SA 8"ø SA 8"ø SARRRR R R R R R R R R R R RR R R R R RRRR(TYP. OF 25) 8"ø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© 2023 26560 AGOURA ROAD, SUITE 106 CALABASAS, CA 91302 310.670.9144 A S S O C I A T E S ARCHITECTS + ENGINEERS S H E P P H I R D will.s@shep-ae.com 1 12-02-22 SD PRICING 2 2-10-23 DD PRICING 3 9-07-23 PHASE 2 90% CD Atlantic Beach Country Club Phase 2 Construction Documents 1600 Selva Marina Drive Atlantic Beach, FL 32233 1/4" = 1'-0" 1-M4.2PHASE 2 -MAIN CLUBHOUSE MECHANICALPARTIAL PLAN -DINING ROOM, GRILL & DININGPATIO2022-352 Author1/4" = 1'-0"1-M4.2 1 PHASE 2 - MAIN CLUBHOUSE MECHANICAL PARTIAL PLAN - LEVEL 1 - DINING ROOM, GRILL & DINING PATIO