ABCC P2 - Bldg 1 - 1-M4.4_11 1-M4.5 1 1-M4.5 16"x16"EXISTING 12"x14" SA EXISTING 14"x12" RA EXISTING 15"x30" RAEXISTING 18"x27" SAEXISTING 14"x14" SAEXISTING 16"x10" RAEXISTING 12"x14" SAAHU 9 AHU 5 AHU 7 AHU 2B AHU 2A AHU 3 AHU 4 22"x18" OA22"x18" OA22"x14" OA AHU 6 16"x16" SA 14"x14" RA 14"x12" RA14"x12" SA 16"x16" SA (EXISTING) (EXISTING) (EXISTING)(EXISTING)(EXISTING) (EXISTING) (EXISTING) (EXISTING) EXISTING 18"x20" RA 14"x14" OA MVD EXISTING 18"x20" RA MVD MVD 14"x14" OA MVD 8"x8" OA MVD14"x14" OA8"x8" OAMVD 10"x10" OA MVD MVD MVD EXISTING 14"x14" RA EXISTING 14"x14" RAEXISTING 16"x16" SAEXISTING 10"ø SA EXISTING 12"x12" TA EXISTING 16"x16" SAEXISTING 14"x14" RA1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 2 3 3 4 444 4 8"x8" OAT 5 6 7 6 1-M4.5 2 1-M4.5 MVD 4 1-M4.5 3 1-M4.5 5 1-M4.5 5 1-M4.5 4 4 4 4 4 4 4 1 1 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION. ANY CONFLICTS AND DISCREPANCIES SHALL NOTIFY THE ARCHITECT PRIOR TO THE CONSTRUCTION START. 2. DUCTWORK SHALL MOUNT AS HIGH AS POSSIBLE TO MAXIMIZE THE CEILING SPACE. 3. PROVIDE MANUFACTURER'S CLEARANCE AROUND ALL ABOVE CEILING MECHANICAL EQUIPMENT. 4. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPE. 5. PROVIDE REMOTE BALANCING DAMPERS FOR ANY NON-ACCESSIBLE DIFFUSERS. 6. PROVIDE CEILING ACCESS PANEL FOR ANY NON-ACCESSIBLE CEILING EQUIPMENT AND DAMPERS. 7. EXHAUST OUTLETS SHALL BE LOCATED MININUM 10'-0" HORIZONTALLY OR 3'-0" ABOVE ANY BUILDING OPENING AND INTAKE OPENING. 8. VERIFY EXISTING LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, AND SYSTEM COMPONENTS PRIOR TO DEMOLITION. IF EXISTING CONDITIONS ARE DIFFERENT THAN WHAT IS INDICATED ON THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE OWNER/ARCHITECT PRIOR TO PROCEEDING WITH WORK. 9. WHERE TEMPORARY SHUTDOWN OF SERVICES IS NEEDED FOR AREAS THAT WILL BE OCCUPIED DURING CONSTRUCTION, THE SHUTDOWN SHALL BE CLOSELY COORDINATED WITH OWNER. ARRANGE WORK TO ASSURE THAT ANY SHUTDOWN OF SERVICES TIME IS AS MINIMAL AS POSSIBLE. GENERAL NOTES 1. SEE 1/1-M4.2 FOR CONTINUATION. 2. REPLACE A MINIMUM OF 20’-0" OF EXISTING SUPPLY AND RETURN DUCTWORK BEYOND THE MEZZANINE WALL. HAVE THE OWNER'S ENVIRONMENTAL CONSULTANT CONFIRM IF ANY FURTHER REMOVAL IS REQUIRED. CONTRACTOR TO FIELD VERIFY SIZES AND LOCATIONS OF THE EXISTING DUCTWORK AND REPLACE WITH THE SAME SIZE AS EXISTING. 3. CONTRACTOR TO FIELD VERIFY CLEAR AREA AT INTERSECTING TRUSSES FOR DUCT TO FIT THROUGH. 4. REPLACE EXISTING SUPPLY AND RETURN DUCTWORK WITHIN THE MEZZANINE AREA. RECONNECT TO EXISTING SUPPLY AND RETURN DUCT IN THE CEILING SPACE. CONTRACTOR TO FIELD VERIFY SIZES AND LOCATIONS OF THE EXISTING DUCTWORK AND REPLACE WITH THE SAME SIZE AS EXISTING. 5. NEW AHU-9 THERMOSTAT WITH BACNET MS/TP INTERFACE. COORDINATE LOCATION WITH OWNER. APPROVE BY ENGINEER. 6. BAS NETWORK CONTROLLER. 7. VRF SYSTEM CONTROLLER. KEYNOTES DRAWN BY: PROJECT NO.: SCALE: REVISION NO.DATE DESCRIPTION THE INFORMATION SHOWN ON THESE DRAWINGS IS OWNED BY AND IS THE PROPERTY OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. NO PART THEREOF SHALL BE COPIED, ADAPTED, OR DISTRIBUTED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. COPYRIGHT © 2023 26560 AGOURA ROAD, SUITE 106 CALABASAS, CA 91302 310.670.9144 A S S O C I A T E S ARCHITECTS + ENGINEERS S H E P P H I R D will.s@shep-ae.com 1 12-02-22 SD PRICING 2 2-10-23 DD PRICING 3 9-07-23 PHASE 2 90% CD Atlantic Beach Country Club Phase 2 Construction Documents 1600 Selva Marina Drive Atlantic Beach, FL 32233 As indicated 1-M4.4PHASE 2 -MAIN CLUBHOUSE MECHANICALPARTIAL PLAN -LEVEL 2 -HVAC/MECHANICALMEZZANINE2022-352 AuthorPARTIAL PLAN1-M4.4 1 PHASE 2 - MAIN CLUBHOUSE MECHANICAL PARTIAL PLAN - LEVEL 2 - HVAC/MECHANICAL MEZZANINE