Loading...
ABCC P2 - Bldg 1 - 1-S1.11_1T1 @ 2'-0" O.C. MAXSEE 1-S1.12 FOR PATIO ROOF FRAMING 5.25X14 PSL PLUS5.25X14 PSL PLUS@ 2'-0" O.C. MAX 2x1219 0-S6.13 15 0-S6.13 TYP TYP 7X14 PSL PLUS (E) BLDG A T2 @ 2'-0" O.C. B C 2.0 2.1 3.1 PRE-ENGINEERED TRUSS GIRDER T2 T2 T2 T2 PRE-ENGINEERED TRUSS GIRDER BY OTHERS PRE-ENGINEERED TRUSS GIRDER BY OTHERS 18 0-S6.13 TYP 14 0-S6.13 27'-11"11'-11 1/8" 4'-5" 44'-3"12'-8 3/4"1'-3 1/8"13'-1"13'-5 5/8"17'-2"B.1 A.1 3.0 D 57'-8 1/2"5 0-S6.14 6 0-S6.14 18 0-S6.14 NOTES: 1. SEE 0-S0.10 FOR STRUCTURAL GENERAL NOTES. 2. SEE ARCH FOR ADDITIONAL INFORMATION AND DIMENSIONS. 3. DECK BEARING ELEVATION VARIES RELATIVE TO FIRST FLOOR REFERENCE ELEVATION = 0'-0" UNO. SEE TRUSS PROFILES ON 0-S6.14. 4. INDICATES DIRECTIONAL SPAN OF 5/8" PLYWOOD SHEATHING, SEE DETAIL . 5. Tx INDICATES PRE-ENGINEERED WOOD TRUSS. SEE GENERAL NOTES AND 0-S6.14 FOR TRUSS PROFILES. SEE ARCH FOR TRUSS BEARING ELEVATIONS. 6. SEE FOR TYPICAL WOOD HEADER SCHEDULE FOR HEADERS NOT SHOWN ON PLAN. 7. SEE FOR STANDARD MASONRY LINTEL SCHEDULE. 8. SEE FOR TYPICAL TOP PLATE SPLICE AT WOOD STUD WALL. 9. SEE FOR FLORIDA BUILDING CODE FASTENING SCHEDULE. 10. SEE FOR INTERIOR NON-BEARING WALL BRACING AT ROOF FRAMING. 11. CONTRACTOR TO FIELD VERIFY EXISTING DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION. NOTIFY ENGINEER OF ANY DISCREPANCIES. /4 0-S6.12 /10 0-S6.12 /9 0-S6.12 /13 0-S6.12 /18 0-S6.12 /17 0-S6.12 DRAWN BY: PROJECT NO.: SCALE: REVISION NO.DATE DESCRIPTION THE INFORMATION SHOWN ON THESE DRAWINGS IS OWNED BY AND IS THE PROPERTY OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. NO PART THEREOF SHALL BE COPIED, ADAPTED, OR DISTRIBUTED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. COPYRIGHT © 2023 26560 AGOURA ROAD, SUITE 106 CALABASAS, CA 91302 310.670.9144 A S S O C I A T E S ARCHITECTS + ENGINEERS S H E P P H I R D will.s@shep-ae.com 1 12-02-22 SD PRICING 2 2-10-23 DD PRICING 3 9-07-23 PHASE 2 90% CD This item has been electronically signed and sealed by Holly Jeffreys, Florida license number 82758 on the date and/or time stamp using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Phase 2 As indicated 8/31/2023 7:31:13 PMAutodesk Docs://2022-352 ABCC/R22_ABCC_BLDG1_STRUCT.rvt1-S1.11PHASE 2 -MAIN CLUBHOUSE KITCHENEXPANSION ROOF FRAMING PLAN2022-352 SM Atlantic Beach Country Club 1600 Selva Marina Drive Atlantic Beach, FL 32233 1/4" = 1'-0"1-S1.11 1 PHASE 2 - MAIN CLUBHOUSE KITCHEN EXPANSION ROOF FRAMING PLAN